User Guide for PEDROLLO models including: VXCm 15-50, VXC 15-50, VXCm 20-50, VXC 20-50, VXCm 30-50, VXC 30-50, VXC 40-50, VORTEX VXC Submersible Pumps, VORTEX VXC, VORTEX, VXC, VORTEX Submersible Pumps, VXC Submersible Pumps, Submersible Pumps, Pumps

Andrea Geroli

VORTEX

30 avr. 2024 — INSTALLATION AND USE. The VXC series is constructed from thick cast iron, offering exceptional robustness, abrasion resistance, and longev-.

Submersible pumps VORTEX - Pedrollo

VXC Submersible pumps VORTEX PERFORMANCE RANGE • Flow rate up to 1250 l/min (75 m3/h) • Head up to ※20 m INSTALLATION AND USE The VXC series is constructed from thick cast iron, offering exceptional robustness, abrasion resistance, and longev-ity. Featuring VORTEX-type impellers, these pumps are designed to drain sewage, wastewater, sludge-mixed water, activated and putrid sludge.

Technical sheet

VXC 50-65 | Pedrollo S.p.A.

PDF preview unavailable. Download the PDF instead.

VXC-50-65 EN 50Hz
VXC Submersible pumps
 High-quality materials and robust construction ensure superior performance and reliability

VORTEX
Sewage Civil use Industrial use

PERFORMANCE RANGE
· Flow rate up to 1250 l/min (75 m3/h) · Head up to 20 m
INSTALLATION AND USE The VXC series is constructed from thick cast iron, offering exceptional robustness, abrasion resistance, and longevity. Featuring VORTEX-type impellers, these pumps are designed to drain sewage, wastewater, sludge-mixed water, activated and putrid sludge. They are suitable for a wide range of applications, including sewers, tunnels, excavations, canals, and underground parking facilities
APPLICATION LIMITS
· Depth below water level up to 10 m
(with an appropriately sized power cable)
· Liquid temperature up to +40 °C · Suspended solids transfer:
­ up to Ø 50 mm for VXC /50 ­ up to Ø 65 mm for VXC /65
· Continuous operation of the pump even when com-
pletely uncovered.

INCLUDES  Power cable length 10 m  Float switch (exclusive to single-phase models)  Switchbox compatible with single-phase versions
AVAILABLE UPON REQUEST  QES control panel for three-phase pumps  Different voltage requirements 60 Hz frequency
WARRANTY  The warranty for three-phase models remains valid
only if the motor's built-in thermal protector is properly connected to the control panel. This connection is essential for the warranty's applicability.
PATENTS - TRADE MARKS - MODELS
· Patent No. IT0001428923 · Registered Community Model No. 008625685-0001,
No. 008625685-0002

50 Hz | VXC

CURVES AND PERFORMANCE DATA

0

50

0

50

22

20 VXC 40/50 18

Head H (metres) 4

16 VXC 30/50

14 VXC 20/50
12 VXC 15/50
10

8

6

4

2

0

0

100

200

300

0

10

20

100 400

150 100

500

600

30
Flow rate Q 4

200 150

700 40

800 50

250 200

50 Hz
US g.p.m. Imp g.p.m.
feet

60 VORTEX Passage Ø 50 mm 50
40

30

20

10

900

1000

l/min 0

60

m³/h

TYPE

Single-ph. Three-ph.

VXCm 15/50 VXC 15/50

VXCm 20/50 VXC 20/50

VXCm 30/50 VXC 30/50

­

VXC 40/50

POWER (P2) m³/h 0 6 12 18 24 30 36 42 51 60 63 kW HP Q l/min 0 100 200 300 400 500 600 700 850 1000 1050

1.1 1.5

12 11 9.9 8.6 7 5 2.5

1.5 2.2

2 3

H metres

13.5 16.5

12.5 11.4 10.2 15.5 14.4 13.2

8.7 11.9

7 10.3

5 8.5

2.5 6.4

2.5

3

4

20 19 18.1 17.1 16 14.7 13.2 11.4 8 3.6 2

Head H (metres) 4

0

50

100

150

200

250

0

50

100

150

200

16

VXC 40/65

14

12

VXC 30/65

10 VXC 20/65
8 VXC 15/65
6

300

US g.p.m.

250

Imp g.p.m.

feet

50

VORTEX

40

Passage Ø 65 mm

30

20

4 10
2

0 0

100

200

300

400

500

600

700

800

900

1000

1100

1200 l/min 0

0

10

20

30

40

50

60

70

m³/h

Flow rate Q 4

TYPE

Single-ph. Three-ph.

VXCm 15/65 VXC 15/65

VXCm 20/65 VXC 20/65

VXCm 30/65 VXC 30/65

­

VXC 40/65

Q = Flow rate H = Total manometric head

POWER (P2)

kW HP

1.1 1.5

1.5

2

2.2 3

3

4

Q

m³/h l/min

0 0

12 18 24 30 36 42 51 60 63 72 75 200 300 400 500 600 700 850 1000 1050 1200 1250

8 7 6 5 4 2.8 2 1

H metres

9.5 12

8.5 7.6 6.6 11 10.3 9.3

5.4 8.2

4.3 7

3.3 5.8

2 4

1 2.6 2.3 1.5

15.5 15 14 13 11.6 10 8.6 6.3 4.3 3.7 2.3 2

Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.
VXC | 50 Hz

VXC Technical data

ABSORPTION
TYPE Single-phase VXCm 15/50 VXCm 20/50 VXCm 30/50 VXCm 15/65 VXCm 20/65 VXCm 30/65

VOLTAGE
230 V 8.5 A 9.0 A 12.0 A 8.5 A 9.0 A 12.0 A

DIMENSIONS AND WEIGHT
a

TYPE Three-phase VXC 15/50 VXC 20/50 VXC 30/50 VXC 40/50 VXC 15/65 VXC 20/65 VXC 30/65 VXC 40/65
Typical installation

VOLTAGE
400 V 3.4 A 3.7 A 5.0 A 6.2 A 3.4 A 3.7 A 5.0 A 6.2 A

p (minimum)

h

DN

f

h1 d

b

c

e

(minimum)

TYPE

Single-phase Three-phase

VXCm 15/50 VXC 15/50

VXCm 20/50 VXC 20/50

VXCm 30/50 VXC 30/50

­

VXC 40/50

VXCm 15/65 VXC 15/65

VXCm 20/65 VXC 20/65

VXCm 30/65 VXC 30/65

­

VXC 40/65

PORT
DN
2½"
3"

Passage of solid bodies a b c

DIMENSIONS mm

h

h1 d e

50 mm

487

162 119 212

167 242 75

513 | 487

513

65 mm

521

180 120 240

201 246 85

547 | 521

547

adjustable

kg

f

p

1~ 3~

42.1 40.0

43.0 42.0

48.0 44.0

­ 48.0 800 800
44.0 42.5

45.1 44.0

49.8 46.0

­ 49.8

PALLET CAPACITY

TYPE

Single-phase Three-phase

VXCm 15/50 VXC 15/50

VXCm 20/50 VXC 20/50

VXCm 30/50 VXC 30/50

­

VXC 40/50

VXCm 15/65 VXC 15/65

VXCm 20/65 VXC 20/65

VXCm 30/65 VXC 30/65

­

VXC 40/65

50 Hz | VXC

NO. OF PUMPS
16 16 12 | 16 12 12 12 12 12

MATERIALS AND COMPONENTS

1 Pump body

Cast iron with cataphoresis treatment

2 Impeller

Cast iron VORTEX type with cataphoresis treatment

3 Motor holder

Cast iron with cataphoresis treatment

4 Motor bracket

Cast iron with cataphoresis treatment

5 Motor shaft

Stainless steel AISI 431

6 Double mechanical seal with interposed oil chamber

Seal
STA-22 STA-20

Shaft
Ø 22 mm Ø 20 mm

Location
Motor side Pump side

Materials
Ceramic / Graphite / NBR Silicon carbide/Silicon carbide/NBR

7 Electric Motor
VXCm: single-phase 230 V - 50 Hz with thermal motor protection
VXC: three-phase 400 V - 50 Hz  with winding integrated thermal motor protection (to be con-
nected to the switchboard supplied on request)
­ Insulation: class F ­ Protection rating: IP X8

8 Power cord  10 metres 'H07 RN-F' type

9 Switchboard

(exclusive to single-phase models)

8

With capacitor and manual reset motor protection switch

5
10 Float switch (exclusive to single-phase models)
4

Power switchboard (standard for single-phase versions)
9
3 7
6

OPTIONAL - Support base
(Cod. ASSBAVM)

10

2

1

VXC | 50 Hz


Adobe PDF Library 17.0