Capacitors Accessories for Capacitors . . . . . . . . . . . . . . . . . . . . . . .C-9 Motor Run Capacitors . . . . . . . . . . . . . . . . . .C-5 C-8, C-10 Motor Start Capacitors . . . . . . . . . . . . . . . . . . . . . . . . . . .C-3 Turbo 200TM Universal Motor Run & Start Capacitors . . . . . . . .C-4
Compressor and Crankcase Heaters . . . . . . . . .C-44 C-45 Condensate Pumps . . . . . . . . . . . . . . . . . . . . . . .C-27 C-28 Contactors
MARS 780 Dual Purpose Contactors . . . . . . . .C-11 C-16 Furnas NEMA Contactors & Starters . . . . . . . . . . . . . .C-17 GE Definite Purpose Contactors . . . . . . . . . . . . . . . . . .C-18 Magnetic Line Contactors . . . . . . . . . . . . . . . . . . . . . . .C-20 MARS Definite Purpose Contactors . . . . . . . . . . . . . . .C-19 Universal Contactor Enclosure . . . . . . . . . . . . . . . . . . .C-18 Crankcase Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-44 Defrost Thermostats . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-41 Electric Heat Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-46 Fan Centers MARS Fan Centers . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-20 Fan & Limit Thermostats . . . . . . . . . . . . . . . . . .C-49 C-50 Flame Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-52 Heat Pump Thermostats . . . . . . . . . . . . . . . . . . . . . . . . .C-43 Hot Suface Igniters (Pilot Burners) . . . . . . . . . . . . . . . .C-51 Klixon Motor Protectors . . . . . . . . . . . . . . . . . . . . . . . . .C-40
Description
Page No.
Klixon Pressure Switches . . . . . . . . . . . . . . . . . . . . . . . .C-42 Klixon Thermostats . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-41 Leak Detectors / Renewal Parts . . . . . . . . . . . . . . . . . . .C-36 MARS Motor Protectors . . . . . . . . . . . . . . . . . . . . . . . . .C-39 MARS Pressure Switches . . . . . . . . . . . . . . . . . .C-42 C-43 Relays
Current Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-33 Enclosed Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-33 General Purpose Relays . . . . . . . . . . . . . . . . . . . . . . . .C-31 General Purpose Switching Relays . . . . . . . . . .C-31 C-32 MARS Potential Relays . . . . . . . . . . . . . . . . . . .C-34 C-35 Sequencers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-47 C-48 Solid State Motor Starting Devices . . . . . . . . . . . . . . . .C-37 Solid State Timers . . . . . . . . . . . . . . . . . . .C-37 C-38, C-39 Start Assists . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-29 C-30 Surge Protection Devices . . . . . . . . . . . . . . . . . . .C-26, C-27 Thermocouples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-50 Transformers GE IP Core & Coil Transformers . . . . . . . . . . . . . . . . . .C-23 Jard Transformers . . . . . . . . . . . . . . . . . . . . . . .C-24 C-25 MARS Transformers . . . . . . . . . . . . . . . . . . . . .C-21 C-23
C2
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com
COMPONENTS
Motor Start Capacitors
Electrolytic Capacitors for Motor Starting Applications
Start capacitor case dimensions chart. Capacitor accessories on page C-9.
Features:
· The largest assortment of replacements in the industry!
· Smallest dimensions for general replacements.
· Hermetically sealed black Bakelite case permanently protects the capacitor from oil, dirt, grease or moisture.
· New and improved terminal construction capable of withstanding increased heat. This terminal will generate less heat when applied under severe hot humid environment.
· 50/60 Hz
· UL/ULc
®
Blue BoxTM
110/125 Dual Voltage AC
MARS NO.
11002 11003 11004 11005 11006 11007 11008 11009 11010 11112 11011 11013 11014 11015 11016 11017 11018 11019 11020 11021 11022 11023 11024 11071 11025 11026 11027 11047 11028 11072 11029 11073 11030 11074
MICROFARAD MIN - MAX.
21-25 25-30 30-36 36-43 43-56 56-72 72-88 88-108 108-130 124-156 130-156 145-175 161-193 189-227 200-240 216-259 233-292 270-324 300-360 324-388 340-408 378-440 400-480 430-516 460-552 540-648 590-708 645-774 708-850 815-970 829-995 850-1020 1000-1200 1290-1548
CASE SIZE
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 4 4 4 4 4 4 4 7 7
MARS suggests applying a bleed resistor (MARS PN 93007) on start capacitors used in conjunction with starting relays
*Capacitors may be put in different case sizes occasionally, but will not be larger than those stated.
165 Volts AC
MARS NO.
11075 11076 11077 11031 11032 11033 11034 11078 11035 11036 11079 11080 11037 11081 11082 11083
MICROFARAD MIN - MAX.
72-88 88-108 108-130 124-149 145-175 161-193 189-227 216-259 233-292 270-324 340-408 378-455 400-480 540-648 710-850 810-972
220/250 Dual Voltage AC
MARS NO.
11038 11039 11040 11041 11042 11043 11084 11137 11044 11045 11046 11148 11049 11050 11051 11052 11053 11054 11085 11086 11087 11088 11089 11090 11091
MICROFARAD MIN - MAX.
21-25 25-30 30-36 36-43 43-56 56-72 59-71 64-77 72-88 88-108 108-130 124-156 145-175 161-193 189-227 216-259 233-292 270-324 280-336 320-384 340-408 378-455 400-480 430-516 630-750
330 Volts AC
MARS NO.
11055 11056 11057 11058 11059 11060 11160 11061 11062 11063 11064 11165 11092 11066 11067 11068 11069 11070 11093
MICROFARAD MIN - MAX.
21-25 25-30 30-36 36-43 43-56 56-72 64-77 72-88 88-108 108-130 130-156 124-156 135-162 145-175 161-193 189-227 216-259 270-324 300-360
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
CASE SIZE
1 1 1 1 1 1 1 4 4 4 4 4 4 4 7 7
CASE SIZE
1 1 1 1 1 1 1 4 4 4 4 4 4 6 6 6 6 6 7 7 7 7 7 7 8
CASE SIZE
2 2 2 2 4 4 4 4 4 7 7 7 7 7 7 7 7 7 7
C3
COMPONENTS
TurboTM Products
The Turbo® 200 Family Products
Universal Run & Start Capacitor Replacement. Have the right capacitor for the job every time. The perfect solution for off hour emergency service calls.
Universal HardStart Replacement. One "2-Wire" Turbo® Easy-Start Hardstart can replace any one of four compressor hardstart kits on the market.
12200 and 12300 feature a CPT (Compressor Protector Terminal) for use
with hard start kits. The CPT acts like a kill switch and protects the compressor in the event of
a capacitor failure.
12100 Turbo® 200 Mini
12500 Turbo® 200 Mini - Oval
12200 Turbo® 200
12300 Turbo® 200X
11200 TurbolyticTM 50
11100 TurbolyticTM JR
86150 TurboMeterTM
MARS NO. 12100 12500 12200 12300 11200 11100
DESCRIPTION
Turbo® 200 Mini Turbo® 200 Mini - Oval
Turbo® 200 Turbo® 200 X TurbolyticTM 50 Universal Motor Start Capacitor TurbolyticTM JR
86150
TurboMeterTM See the dual values develop simultaneously on the screen as you create the ratings needed.
MICROFARAD
2.5 mfd - 15 mfd, 370V or 440V
2.5 mfd - 15 mfd, 370V or 440V
2.5 mfd - 67.5 mfd, 370V or 440V
5.0 mfd - 97.5 mfd, 370V or 440V
23 mfd - 302 mfd, 125V to 330V
23 mfd - 208 mfd, 125V to 330V
12600
Turbo® Easy-Start Hardstart
Up to 1 ton 108-130 mfd 1 to 2 tons 189-227 mfd 2.5 to 3 tons 233-280 mfd 3.5 to 5 tons 270 to 324 mfd
MARS Capacitor Tester
Features: · Easy to use · 9V battery and test leads included · Low battery indicator
MARS NO. RANGE RESOLUTION
200 pF
0, 1pF
65746
2000 pF 20 nF 200 nF 2 nF
20 µF
200 µF
2000 µF
20 mF
1 pF 10 pF 100 pF 1 nF
10 nF
100 nF
1 µF
10 µF
ACCURACY TEST FREQUENCY
± (0.5% rdg + 1 dgt + 0.5 pF)
± (0.5% rdg +1 dgt)
820Hz 82 Hz
± (2.0% rdg. + 1dgt) ± (4.0% rdg. + 1dgt)
8.2 Hz
12600 Turbo® Easy-Start
C4
65746
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com
COMPONENTS
Motor Run Capacitors
Single Section Run Capacitors
Capacitor accessories on page C-9.
Features:
· MARS offers the widest selection of ratings in the industry
· Non-PCB capacitors
· Physical interrupter makes our capacitors safe
· Perfect for general replacements--smallest dimensions available
· UL and CSA listings available
· 50/60 Hz
12002
12092
NORMAL
FAIL SAFE MODE
PHYSICAL INTERRUPTER
12026
12102
®
Blue BoxTM
Single Section 370 Volt Oval
MARS NO.
12002 12003 12004 12005 12006 12007 12008 12009 12010 12012 12014 12015 12017 12018 12021 12023 12025 12024 12087 12011 12089 12090
MICROFARAD
2 3 4 5 6 7.5 10 12.5 15 17.5 20 25 30 35 40 45 50 55 60 65 70 80
BASE
A A A A A A A A A A C C C C C C C C C C C D
HEIGHT IN.
1.500 1.500 1.500 1.500 1.500 2.375 2.625 3.000 3.750 3.750 2.375 2.625 2.625 3.000 3.750 3.750 3.750 4.250 4.750 4.750 4.750 3.750
Single Section 370 Volt Round
MARS NO.
MICROFARAD
12092
2
12093
3
12094
4
12095
5
12096
6
12097
7.5
12098
10
12099
12.5
12210
15
12211
16
12212
17.5
12214
20
12215
25
12217
30
12218
35
12221
40
12223
45
12225
50
12226
55
12227
60
12128
65
12229
70
12199
80
12116
100
Single Section 440/370 Volt Oval
MARS NO.
MICROFARAD
12026
2
12019
2.5
12027
3
12028
4
12029
5
12030
6
12031
7.5
12032
10
12033
12.5
12034
15
12036
17.5
12037
20
12040
25
12041
30
12043
35
12045
40
12048
45
12049
50
12050
55
12051
60
12052
65
12130
70
12135
75
12140
80
Single Section 440/370 Volt Round
MARS NO.
12102 12103 12104 12105 12106 12107 12232 12233 12234 12236 12237 12240 12241 12243 12245 12248 12251 12252 12254 12357 12258 12259 12068
MICROFARAD
2 3 4 5 6 7.5 10 12.5 15 17.5 20 25 30 35 40 45 50 55 60 65 70 80 90
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
BASE
M M M M M M M M M M M M M M M M N N N N N N N P
BASE
A A A A A A A A A C C C C C C C C C C D D D D D
BASE
M M M M M M M M M M M M N N N N P P P P P P P
HEIGHT IN.
2.000 2.000 2.000 2.000 2.000 2.000 2.000 2.000 2.375 2.375 2.375 2.625 3.000 3.000 3.750 3.750 3.375 3.750 3.750 4.750 4.750 4.750 4.750 4.750
HEIGHT IN.
1.500 1.500 2.000 2.000 2.375 2.375 2.625 3.750 3.750 2.375 2.375 2.625 3.000 3.750 3.750 4.750 4.750 4.750 4.750 3.750 3.750 3.750 3.750 4.750
HEIGHT IN.
2.000 2.000 2.000 2.000 2.000 2.000 2.375 2.375 2.625 2.750 3.000 3.750 3.375 3.750 3.750 4.750 3.375 3.750 3.750 3.750 4.750 4.750 4.750
C5
COMPONENTS
Motor Run Capacitors
Dual Section Motor Run Capacitors
Dual section run capacitors are used primarily to serve two microfarad applications. They can, however, by making various combinations of parallel connections, be used to obtain many other microfarad ratings.
Capacitor accessories on page C-9.
Features: · MARS offers the widest
selections of ratings in the industry
· Non-PCB capacitors
· Physical interrupter makes our capacitors safe
· Perfect for general replacements-- smallest dimensions available
· UL and CSA listings available · 50/60 Hz
Dual Section 370 Volt Oval
MARS NO.
MICROFARAD
12141 12056 12057 12058 12059 12060 12061 12062 12063 12064 12164 12142 12065 12066 12143 12131 12167 12133 12144 12145 12069 12146 12147 12148 12071 12072 12149 12150 12151 12158 12171 12152 12134 12173 12174 12153 12136 12137 12138 12154 12155 12139 12156 12157 12159 12163 12123
15/3 15/4 15/5 15/10 17.5/4 17.5/5 20/3 20/4 20/5 20/10 20/15 25/3 25/4 25/5 25/7.5 25/8 25/10 25/15 30/3 30/4 30/5 30/7.5 30/10 35/3 35/4 35/5 35/7.5 35/10 40/3 40/4 40/5 40/7.5 40/10 45/3 45/5 45/7.5 45/10 45/15 50/5 55/5 55/7.5 60/5 60/7.5 60/10 65/5 80/5 80/7.5
12141
®
Blue BoxTM
NORMAL
FAIL SAFE MODE
PHYSICAL INTERRUPTER
BASE
C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C D C C D D D
HEIGHT IN.
2.625 2.625 2.625 3.000 2.375 2.375 2.625 2.625 2.625 2.625 4.750 2.625 2.625 2.625 2.625 3.000 3.000 3.000 3.000 3.000 3.000 3.000 3.375 3.000 3.750 3.750 3.000 3.750 3.750 3.750 3.750 3.750 3.750 3.750 3.750 3.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750
Dual Section 370 Volt Round
MARS NO.
12121 12122 12203 12204 12205 12206 12207 12260 12016 12208 12209 12242 12175 12261 12262 12213 12244 12263 12264 12224 12228 12039 12082 12231 12266 12235 12238 12074 12267 12178 12268 12246 12073 12247 12269 12249 12250 12075 12191 12192 12239 12193 12194 12067 12076 12195 12196 12265 12042 12053 12054 12055 12044 12046 12084 12197 12198 12201 12202 12129 12230 12222
MICROFARAD
15/3 15/4 15/5 15/10 17.5/4 17.5/5 20/4 20/5 20/7.5 20/10 20/15 25/3 25/4 25/5 25/7.5 25/10 30/3 30/4 30/5 30/7.5 30/10 30/15 35/3 35/4 35/5 35/7.5 35/10 40/3 40/4 40/5 40/7.5 40/10 45/3 45/4 45/5 45/7.5 45/10 50/3 50/5 50/7.5 50/10 55/5 55/7.5 55/10 60/3 60/5 60/7.5 60/10 65/5 70/5 70/7.5 70/10 75/5 75/7.5 75/10 80/5 80/7.5 80/10 80/12.5 85/5 85/7.5 85/10
BASE
N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N P N N P N P P N N N P P N P N P P P P P P P P P P P P P
C6
Toll Free (800) 445-4155 · Fax (631) 348-7160
www.marsdelivers.com
HEIGHT IN.
3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.875 3.875 3.125 3.875 3.125 3.875 3.875 3.875 3.875 3.875 3.875 3.875 3.875 3.875 3.875 3.875 3.125 3.875 3.125 3.875 4.75 4.75 4.75 3.875 3.875 4.75 3.125 4.75 3.875 3.875 3.875 3.875 3.875 3.875 3.875 3.875 3.875 4.75 4.75 4.75 4.75
®
marsdelivers.com
COMPONENTS
Motor Run Capacitors
Capacitor Base Dimensions
12165
®
Blue BoxTM
Dual Section 440/370 Volt Oval
MARS NO.
12360 12165 12170 12270 12271 12177 12180 12083 12184 12182 12183 12186 12181 12187 12038 12035 12085 12179 12185 12188 12176 12272 12080 12086 12189 12273 12190 12274 12108 12013 12275 12276 12109 12110 12101 12297 12298
MICROFARAD
5/5 10/5 10/10 15/4 15/5 15/10 20/5 20/15 25/5 25/7.5 25/10 25/15 30/4 30/5 30/7.5 30/10 35/3 35/4 35/5 35/7.5 35/8.5 35/10 40/3 40/5 40/7.5 40/10 45/5 45/7.5 50/5 50/7.5 55/5 55/10 60/5 60/7.5 65/10 80/5 80/7.5
BASE
C C C C C C C D D C C D C D C C C C C C C C C C C C D C D C D D D D D D D
HEIGHT IN.
2.625 3.125 3.125 2.625 2.625 3.750 3.375 3.000 3.000 3.750 3.750 3.000 3.750 3.750 3.750 3.750 4.750 3.750 4.750 3.750 3.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 5.750 5.750
Dual Section 440/370 Volt Round
MARS NO.
12111 12118 12356 12350 12115 12354 12351 12112 12353 12355 12278 12279 12113 12114 12126 12120 12281 12282 12352 12077 12070 12283 12119 12284 12091 12078 12285 12286 12220 12287 12088 12079 12219 12288 12127 12289 12172 12290 12291 12124 12253 12292 12293 12299 12160 12294 12295 12296 12161 12358 12359 12162 12255 12166 12169 12168 12125 12047 12257 12216 12117 12022 12020 12001
MICROFARAD
10/5 15/5 15/10 17.5/5 20/5 20/7.5 20/10 20/15 25/3 25/4 25/5 25/7.5 25/10 25/15 30/3 30/4 30/5 30/7.5 30/10 35/3 35/4 35/5 35/6 35/7.5 35/10 40/3 40/4 40/5 40/6 40/7.5 40/10 45/3 45/4 45/5 45/6 45/7.5 45/10 50/5 50/7.5 50/10 50/12.5 55/5 55/7.5 55/10 60/3 60/5 60/7.5 60/10 60/12.5 65/5 65/7.5 65/10 70/5 70/7.5 70/10 75/5 75/7.5 75/10 80/5 80/7.5 80/10 85/5 85/7.5 85/10
BASE
N N N N N N N N N N N N N N N N N N N N N N N P N P P P N P N P N P N N P P P P P P P P P P P P P P P P P P P P P P P P P P P P
HEIGHT IN.
3.125 3.125 3.125 3.125 3.125 3.125 3.875 3.875 3.875 3.875 3.875 3.875 3.625 3.875 3.875 3.875 3.875 3.875 4.750 3.875 3.875 3.875 4.750 3.875 4.750 3.125 3.125 3.125 4.750 3.875 4.750 3.875 3.750 3.875 4.750 3.875 3.875 3.875 3.875 3.875 3.875 3.875 3.875 3.875 4.750 3.875 3.875 3.875 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.875 4.750 4.750 4.750 4.750 4.750
Base Dimension Key - Oval
KEY
DEPTH IN.
WIDTH IN.
A
1.31
2.16
C
1.91
2.91
D
1.97
3.66
Base Dimension Key - Round
DESCRIPTION
oval fan size oval oval
KEY
DEPTH IN.
M
1.75
N
2.00
P
2.50
MOUNTING STRAP
93031 93032 93033
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
C7
COMPONENTS
USA Motor Run Capacitors
MARS USA Capacitors
Features: · Product of USA · Tested and approved by every
major US motor company and compressor company · 440/370 Dual Voltage Rated · Non-PCB capacitors · Physical interrupter makes our capacitors safe · Meets EIA-456A Test Standard (simulates 60,000 hours of operation) · Meets Tecumseh H-115 · OEM Grade · CSA approved and UL recognized · 5 year warranty
Single Section 370 Volt Oval
Single Section 370 Volt Round
MARS USA NO. 14002
14003
14004
14005
DESCRIPTION
2 MFD 370V OVL 3 MFD 370V OVL 4 MFD 370V OVL 5 MFD 370V OVL
BASE HEIGHT
A 1.50 A 1.50 A 1.50 A 1.50
MARS USA NO. 14098
14210
14212
DESCRIPTION BASE HEIGHT
10 MFD 370V RND M 2.00 15 MFD 370V RND M 2.38 17.5 MFD 370V RND M 2.38
14006 6 MFD 370V OVL
A 1.50 14214 20 MFD 370V RND M 2.65
14007 7.5 MFD 370V OVL A 2.38 14215 25 MFD 370V RND M 3.00
14008 10 MFD 370V OVL A 2.63 14217 30 MFD 370V RND M 3.00
14009 12.5 MFD 370V OVL A 3.00 14218 35 MFD 370V RND M 3.75
14010 15 MFD 370V OVL A 3.75 14012 17.5 MFD 370V OVL A 3.75 14014 20 MFD 370V OVL C 2.38 14015 25 MFD 370V OVL C 2.63 14017 30 MFD 370V OVL C 2.63 14018 35 MFD 370V OVL C 3.00 14021 40 MFD 370V OVL C 3.75
14821 40 MFD 370V RND M 3.75 14823 45 MFD 370V RND N 3.38 14225 50 MFD 370V RND N 3.75 14226 55 MFD 370V RND N 3.75 14227 60 MFD 370V RND N 4.75 14229 70 MFD 370V RND N 4.75
14023 45 MFD 370V OVL C 3.75 14199 80 MFD 370V RND N 4.75
14025 50 MFD 370V OVL C 3.75
14089 70 MFD 370V OVL C 4.75 Single Section 440/370 Volt Round
14090 80 MFD 370V OVL
D 3.75 MARS USA
DESCRIPTION BASE HEIGHT
Single Section 440/370 Volt Oval NO.
MARS
14105 5 MFD 440/370V RND M 2.00
USA
DESCRIPTION BASE HEIGHT 14107 7.5 MFD 440/370V RND M 2.00
NO.
14232 10 MFD 440/370V RND M 2.38
14027 3 MFD 440/370V OVL A 2.00 14833 12.5 MFD 440/370V RND M 2.38 14028 4 MFD 440/370V OVL A 2.00 14029 5 MFD 440/370V OVL A 2.38 14234 15 MFD 440/370V RND M 2.63
14030 6 MFD 440/370V OVL A 2.38 14237 20 MFD 440/370V RND M 3.00
14031 7.5 MFD 440/370V OVL A 2.63 14240 25 MFD 440/370V RND M 3.75
14032 10 MFD 440/370V OVL A 3.75 14241 30 MFD 440/370V RND N 3.38
14033 12.5 MFD 440/370V OVL A 3.75 14243 35 MFD 440/370V RND N 3.75
14034 15 MFD 440/370V OVL C 2.38 14245 40 MFD 440/370V RND N 3.75 14037 20 MFD 440/370V OVL C 2.63 14248 45 MFD 440/370V RND N 4.75 14040 25 MFD 440/370V OVL C 3.00 14041 30 MFD 440/370V OVL C 3.38 14251 50 MFD 440/370V RND P 3.38 14043 35 MFD 440/370V OVL C 3.75 14252 55 MFD 440/370V RND P 3.75
14045 40 MFD 440/370V OVL C 4.75 14256 65 MFD 440/370V RND P 3.75
14048 45 MFD 440/370V OVL C 4.75 14254 60 MFD 440/370V RND P 3.75
14049 50 MFD 440/370V OVL C 4.75 14258 70 MFD 440/370V RND P 4.75
14050 55 MFD 440/370V OVL C 4.75 14259 80 MFD 440/370V RND P 4.75 14051 60 MFD 440/370V OVL D 3.75
14140 80 MFD 440/370V OVL D 4.75
Dual Section 370 Volt Oval
MARS USA NO.
DESCRIPTION BASE HEIGHT
14066 25/5 MFD 370V OVL C 2.63
Dual Section 440/370 Volt Round
MARS USA NO.
DESCRIPTION
BASE HEIGHT
14353 25/3 MFD 440/370V RND N 3.88
14069 30/5 MFD 370V OVL C 3.00 14278 25/5 MFD 440/370V RND N 3.88
14072 35/5 MFD 370V OVL C 3.75 14279 25/7.5 MFD 440/370 RND N 3.88
14171 40/5 MFD 370V OVL C 3.75 14126 30/3 MFD 440/370V RND N 3.88
14174 45/5 MFD 370V OVL C 3.75 14281 30/5 MFD 440/370V RND N 3.88
14282 30/7.5 MFD 440/370V RND N 3.88
Dual Section 440/370 Volt Oval
14077 35/3 MFD 440/370V RND N 3.88
MARS USA
DESCRIPTION
BASE HEIGHT 14070 35/4 MFD 440/370V RND N 3.88
NO.
14283 35/5 MFD 440/370V RND N 3.88
14184 25/5 MFD 440/370V OVL C 3.75 14284 35/7.5 MFD 440/370V RND P 3.88
14187 30/5 MFD 440/370V OVL D 3.75 14091 35/10 MFD 440/370V RND N 4.75
14185 35/5 MFD 440/370V OVL C 4.75 14078 40/3 MFD 440/370V RND P 3.13
14188 35/7.5 MFD 440/370V OVL C 3.75 14286 40/5 MFD 440/370V RND P 3.13
14086 40/5 MFD 440/370V OVL C 4.75 14287 40/7.5 MFD 440/370V RND P 3.88
14189 40/7.5MFD 440/370V OVL C 4.75 14190 45/5 MFD 440/370V OVL D 4.75 14297 80/5 MFD 440/370V OVL D 5.75 14298 80/7.5MFD 440/370 OVL D 5.75
14088 40/10 MFD 440/370V RND N 4.75 14079 45/3 MFD 440/370V RND P 3.88 14288 45/5 MFD 440/370V RND P 3.88 14289 45/7.5 MFD 440/370V RND N 3.88 14172 45/10 MFD 440/370V RND P 3.88
Dual Section 370 Volt Round
MARS USA NO.
DESCRIPTION BASE HEIGHT
14260 20/5 MFD 370V RND N 2.63
14261 25/5 MFD 370V RND N 2.63
14264 30/5 MFD 370V RND N 3.13
14266 35/5 MFD 370V RND N 3.88
14178 40/5 MFD 370V RND N 3.88
14268 40/7.5 MFD 370V RND N 3.88
14269 45/5 MFD 370V RND P 3.88
14249 45/7.5 MFD 370V RND N 3.88
14191 50/5 MFD 370V RND N 3.88
14192 50/7.5 MFD 370V RND P 3.13
14239 50/10 MFD 370V RND P 3.88
14193 55/5MFD 370V RND N 4.75
14194 55/7.5 MFD 370V RND N 4.75
14195 60/5 MFD 370V RND P 3.88
14196 60/7.5 MFD 370V RND N 4.75
14054 70/7.5 MFD 370V RND P 3.88
14290 50/5 MFD 440/370V RND P 14291 50/7.5 MFD 440/370V RND P 14124 50/10 MFD 440/370V RND P 14299 55/10 MFD 440/370V RND P 14292 55/5 MFD 440/370V RND P 14293 55/7.5 MFD 440/370V RND P 14294 60/5 MFD 440/370V RND P 14295 60/7.5 MFD 440/370V RND P 14296 60/10 MFD 440/370V RND P 14358 65/5 MFD 440/370V RND P 14359 65/7.5 MFD 440/370V RND P 14162 65/10 MFD 440/370V RND P 14255 70/5 MFD 440/370V RND P 14166 70/7.5 MFD 440/370V RND P 14169 70/10 MFD 440/370V RND P 14257 80/5 MFD 440/370V RND P 14216 80/7.5 MFD 440/370V RND P 14117 80/10 MFD 440/370V RND P
3.88 3.88 3.88 3.88 3.88 3.88 3.88 3.88 3.88 3.875 3.875 4.75 4.75 4.75 4.75 4.88 4.75 4.75
14197 80/5 MFD 370V RND P 3.88
14198 80/7.5 MFD 370V RND P 3.88
14201 80/10 MFD 370V RND P 3.88
Capacitor Base Dimensions
Base Dimension on page C-7
C8
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com
COMPONENTS
MARS Mini-Split Run Capacitors
MARS mini-split motor run capacitors are epoxy/resin sealed and widely used as the start-up and/or run capacitor for your motor. They feature very small dissipation factor and inherent temperature rise, high insulation resistance, and stable capacitance.
Specifications:
· Ambient temperature: 70° C · Rated voltage: 450 VA · Capacitance tolerance: ±5 · 50/60 Hz · Standard: IEC252-2001
MARS NO.
12380 12381 12382 12383 12384 12385 12386 12388 12390
DESCRIPTION
1 MFD X 450V 1.5 MFD X 450V 2 MFD X 450V 2.5 MFD X 450V 3 MFD X 450V 3.5 MFD X 450V 4 MFD X 450V 5 MFD X 450V 6 MFD X 450V
DIMENSIONS H D W
1-1/2 X 1/2 X 1 1-1/2 X 1/2 X 1 1-1/2 X 1/2 X 1 1-1/2 X 3/4 X 1-1/4 1-1/2 X 3/4 X 1-1/4 1-7/8 X 3/4 X 1-3/8 1-7/8 X 3/4 X 1-3/8 1-7/8 X 7/8 X 1-3/8 1-7/8 X 1 X 1-1/2
Motor Run Capacitors
QC-6 Kit
93001
For conversion of screw-type connections
on relays
Resistor for Start Capacitors
93007
2 watt (15,000 ohm) Resistors, 10/Pk
QC-13 for Start Capacitors
93106
10 pc 2 watt (15,000 ohm) resistors with .25-in female spade
connectors, 10/Pk
Snap-on Mounting Brackets for Motor Start Capacitors
93026 93027 93028
2.75 in 3.38 in 4.38 in
Sold in 10 pack
Case Dimensions*
CASE SIZE 1 2 4 5 6 7 8
DIAMETER 1.44 1.44 1.81 1.81 2.06 2.06 2.56
LENGTH 2.75 3.38 3.38 4.38 3.38 4.38 4.38
*Capacitors may be put in different case sizes ocassionally, but will not be larger than those stated.
Accessories For Relays & Capacitors
Protector (boots) for Motor Run Capacitors
93011
1 Hole Boot, 25/Pk
93012
2 Hole Boot, 25/Pk
Wrap-Around Brackets for Motor Run Capacitors
93014
Oval 1.94 x 2.78 for base A, 10/Pk
93015
Oval 1.97 x 2.94 for base C, 10/Pk
93116
Oval 2.25 x 3.66 for base D, 10/Pk
Mounting Brackets for Round Capacitors
93031SnaFpor-1o.6n3 iMn aondu1n.7t5iinn gdiamBrackets for Motor Start Capacitors
93032
For 2.0 in diam
93033
For 2.50 in diam
Sold in 5 pack
Bakelite End Caps for Motor Start Capacitors
93018 93019 93020 93021
93022 93023 93024 93025
BEC-1 1.44 in BEC-2 1.81 in BEC-3 2.06 in BEC-4 2.56 in Sold in 10 pack
For mounting OFF MOTOR. Leads on top side.
TEC-1 1.44 in TEC-2 1.81 in TEC-3 2.06 in TEC-4 2.56 in Sold in 10 pack
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
C9
COMPONENTS
Motor Run Capacitors
Single Section Run Capacitors
370 VOLT
MFD
OVAL MARS NO.
ROUND MARS NO.
OVAL ROUND JARD NO. JARD NO.
2
12002 12092 12902 12992
3
12003 12093 12903 12993
4
12004 12094 12904 12994
5
12005 12095 12905 12995
6
12006 12096 12906 12996
7.5 12007 12097 12907 12997
10
12008 12098 12908 12998
12.5 12009 12099 12909 12999
15
12010 12210 12910 12710
16
12211
12911
17.5 12012 12212 12912 12712
20
12014 12214 12914 12714
25
12015 12215 12915 12715
30
12017 12217 12917 12717
35
12018 12218 12918 12718
40
12021 12221 12921 12721
45
12023 12223 12923 12723
50
12025 12225 12925 12725
55
12024 12226 12924 12726
60
12087 12227 12987 12727
65
12011 12128 12988 12828
70
12089 12229 12989 12729
80
12090 12199 12990 12899
100
12116
12916
440/370 VOLT
MFD
OVAL MARS NO.
ROUND MARS NO.
OVAL ROUND JARD NO. JARD NO.
2
12026 12102 12926 12802
2.5 12019
12919
3
12027 12103 12927 12803
4
12028 12104 12928 12804
5
12029 12105 12929 12805
6
12030 12106 12930 12806
7.5 12031 12107 12931 12807
10
12032 12232 12932 12732
12.5 12033 12233 12933 12733
15
12034 12234 12934 12734
17.5 12036 12236 12936 12736
20
12037 12237 12937 12737
25
12040 12240 12940 12740
30
12041 12241 12941 12741
35
12043 12243 12943 12743
40
12045 12245 12945 12745
45
12048 12248 12948 12748
50
12049 12251 12949 12751
55
12050 12252 12950 12752
60
12051 12254 12951 12754
65
12052 12357 12952 12657
70
12130 12258 12830 12758
75
12135
12831
80
12140 12259 12840 12759
90
12068
12868
C10
Dual Section Run Run Capacitors
370 VOLT
MFD
OVAL MARS NO.
ROUND MARS NO.
OVAL ROUND JARD NO. JARD NO.
15/3 15/4 15/5 15/10 17.5/4 17.5/5 20/3 20/4 20/5 20/7.5 20/10 20/15 25/3 25/4 25/5 25/7.5 25/8 25/10 25/15 30/3 30/4 30/5 30/7.5 30/10 30/15 35/3 35/4 35/5 35/7.5 35/10 40/3 40/4 40/5 40/7.5 40/10 45/3 45/4 45/5 45/7.5 45/10 45/15 50/3 50/5 50/7.5 50/10 55/5 55/7.5 55/10 60/3 60/5 60/7.5 60/10 65/5 70/5 70/7.5 70/10 75/5 75/7.5 75/10 80/5 80/7.5 80/10 80/12.5 85/5 85/7.5 85/10
12141 12056 12057 12058 12059 12060 12061 12062 12063
12064 12164 12142 12065 12066 12143 12131 12167 12133 12144 12145 12069 12146 12147
12148 12071 12072 12149 12150 12151 12158 12171 12152 12134 12173
12174 12153 12136 12137
12138
12154 12155
12139 12156 12157 12159
12163 12123
12121 12122 12203 12204 12205 12206
12207 12260 12016 12208 12209 12242 12175 12261 12262
12213
12244 12263 12264 12224 12228 12039 12082 12231 12266 12235 12238 12074 12267 12178 12268 12246 12073 12247 12269 12249 12250
12075 12191 12192 12239 12193 12194 12067 12076 12195 12196 12265 12042 12053 12054 12055 12044 12046 12084 12197 12198 12201 12202 12129 12230 12222
12841 12956 12957 12958 12959 12960 12961 12962 12963
12864 12964 12842 12965 12966 12843 12832 12867 12833 12844 12845 12969 12846 12847
12848 12971 12972 12849 12850 12851 12858 12871 12852 12834
12874 12853 12836 12837
12838
12854 12855
12839 12856 12857 12859
12863 12817
12701 12702 12703 12704 12705 12706
12707 12760 12716 12708 12709 12711 12875 12761 12762
12713
12720 12763 12764 12724 12728 12939 12730 12731 12766 12735 12738 12739 12767 12878 12768 12746 12747 12947 12769 12749 12750
12753 12755 12825 12757 12893 12894 12967 12976 12895 12896 12865 12742 12953 12954 12955 12744 12946 12984 12897 12819 12824 12722 12829 12756 12922
Dual Section Run Run Capacitors
440/370 VOLT
MFD
10/5 15/4 15/5 15/10 17.5/5 20/5 20/7.5 20/10 20/15 25/3 25/4 25/5 25/7.5 25/10 25/15 30/3 30/4 30/5 30/7.5 30/10 35/3 35/4 35/5 35/6 35/7.5 35/8.5 35/10 40/3 40/4 40/5 40/6 40/7.5 40/10 45/3 45/4 45/5 45/6 45/7.5 45/10 50/5 50/7.5 50/10 50/12.5 55/5 55/7.5 55/10 60/3 60/5 60/7.5 60/10 60/12.5 65/5 65/7.5 65/10 70/5 70/7.5 70/10 75/5 75/7.5 75/10 80/5 80/7.5 80/10 85/5 85/7.5 85/10
OVAL MARS NO.
12165 12270 12271 12177 12180
12083
12184 12182 12183 12186 12181 12187 12038 12035 12085 12179 12185 12188 12176 12272 12080 12086 12189 12273
12190 12274 12108 12013
12275 12276 12109 12110
12101
12297 12298
ROUND MARS NO.
12111
12118 12356 12350 12115 12354 12351 12112 12353 12355 12278 12279 12113 12114 12126 12120 12281 12282 12352 12077 12070 12283 12119 12284
12091 12078 12285 12286 12220 12287 12088 12079 12219 12288 12127 12289 12172 12290 12291 12124 12253 12292 12293 12299 12160 12294 12295 12296 12161 12358 12359 12162 12255 12166 12169 12168 12125 12047 12257 12216 12117 12022 12020 12001
OVAL ROUND JARD NO. JARD NO.
12765 12770 12771 12777
12880
12983
12884 12882 12883 12886
12881 12887 12982 12835 12985 12879 12885
12811
12818 12656 12650 12780 12654 12651 12812 12653 12655 12778 12779 12813 12814 12826 12820 12781 12782 12652 12977 12870 12783
12888 12876 12772 12877 12986 12889 12773
12890 12774 12808 12913
12775 12822 12809 12776
12810
12815 12898
12784
12797 12978 12785 12786 12920 12787 12798 12979 12891 12788 12827 12789 12872 12790 12791 12892 12719 12792 12793 12799 12860 12794 12795 12796 12861 12642 12659 12862 12823 12866 12869 12968 12901 12935 12801 12816 12821 12938 12942 12944
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com
COMPONENTS
MARS 780 Definite Purpose Contactors
MARS 780 Definite Purpose Contactors
MARS 780 - 1 pole with shunt contactors are designed for demanding applications. The enclosed body design provides quiet operation and improved durability by reducing the intrusion of dust and dirt. Silver-cadmium oxide contacts provide increased contact life when switching inductive loads.
61720
Features:
· Enclosed body and coil standard cover
· Push to test button
61320
· Quad quick connects
· Box lugs - large window arch design
· Screw terminals and or box lugs available on 30 amp
· Coils - class F insulation
· UL File E96705
1 Pole with Shunt 30 - 40 Amps
MARS NO.
FURNAS NO.
61320 61321 61322 61323
45EG10AJA, 45CG10AJA, 45DG10AJA 45EG10AFA, 45CG10AFA, 45DG10AFA 45EG10AGA, 45CG10AGA, 45DG10AGA 45EG10ALA, 45CG10ALA, 45DG10ALA
FLA
LOCKED
NON
ROTOR AMPS INDUCTIVE
240V 277V AMPS
COIL VOLTS
TERMINATION
24
30 180 180
120
40
Screw Type
208-240
277
61720 45EG10AJAL
24
61721 45EG10AFAL
120
MARS 780 Definite Purpose Contactors
MARS 780 - 2 pole contactors are designed for demanding applications. The enclosed body design provides quiet operation and improved durability by reducing the intrusion of dust and dirt. Silver-cadmium oxide contacts provide increased contact life when switching inductive loads.
61345
Features:
· Enclosed body and coil standard cover
· Push to test button
61755
· Quad quick connects
· Box lugs - large window arch design
· Screw terminals and or box lugs available on 30 amp
· Coils - class F insulation
· UL File E96705
2 Pole 30 - 40 Amps
MARS NO.
FURNAS NO.
FLA
LOCKED ROTOR AMPS
240V 480V 600V
NON INDUCTIVE
AMPS
COIL VOLTS
61345 61346 61347 61348 61349
45EG20AJ, 45CG20AJ, 45DG20AJ
45EG20AF, 45CG20AF, 45DG20AF
45EG20AG, 45CG20AG, 45DG20AG
45EG20AL, 45CG20AL, 45DG20AL
45EG20AH, 45CG20AH, 45DG20AH
30 180 150 120
24 120 40 208-240 277 480
TERMINATION Screw Type
61745 45EG20AJL
24
61722 45EG10AGAL 30 180 180
61723 45EG10ALAL
61724 45EG10AHAL
61730 61731 61732 61733 61734
45GG10AJAL, 45FG10AJA, 45GG10AJA 45GG10AFAL, 45FG10AFA, 45GG10AFA 45GG10AGAL, 45FG10AGA, 45GG10AGA 45GG10ALAL, 45FG10ALA, 45GG10ALA 45GG10AHAL, 45FG10AHA, 45GG10AHA
40 240 240
40
208-240 Box Lug
277
480
24
120
50
208-240 Box Lug
277
480
61746 45EG20AFL
120
61747 45EG20AGL 30 180 150 120
40 208-240
Box Lug
61748 45EG20ALL
277
61749 45EG20AHL
45GG20AJL, 61755 45FG20AJ,
45GG20AJ
45GG20AFL, 61756 45FG20AF,
45GG20AF
45GG20AGL, 61757 45FG20AG, 40 240 200 160
45GG20AG
45GG20ALL, 61758 45FG20AL,
45GG20AL
45GG20AHL, 61759 45FG20AH,
45GG20AH
480 24 120 50 208-240 277 480
Box Lug
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
C11
COMPONENTS
MARS 780 Definite Purpose Contactors
MARS 780 Definite Purpose Contactors
MARS 780 - 2 pole "Large Body" contactors feature a 2 pole configuration in a 3 pole body for increased durability in demanding applications.
Features: · Large arch window box lugs · Recessed push to test button · Accepts MARS 780 and Furnas auxiliary switches · Use standard MARS 780 replacement coils · Dual QC coil terminals plus screw terminal for easy termination and
jumper arrangements · Coils - class F insulation · UL File E96705
61425
61440
2 Pole - Large Body 30 - 40 Amp
MARS NO.
FURNAS NO.
LOCKED ROTOR AMPS
FLA
240V
480V
600V
NON INDUCTIVE AMPS
COIL VOLTS
61425
42BF15AJ, 42AF15AJ
24
61426
42BF15AF, 42AF15AF
120
30
180
150
120
40
61427
42BF15AG, 42AF15AG
208-240
61428
42BF15AL, 42AF15AL
277
61440
42CF15AJ
24
61441 61442
42CF15AF 42CF15AG
120
40
240
200
160
50
208-240
61443
42CF15AL
277
HORSEPOWER
1 PH
3 PH
240V
240V
3 HP
7.5 HP
5 HP
10 HP
TERMINATION Box Lug Box Lug
C12
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com
COMPONENTS
MARS 780 Definite Purpose Contactors
MARS 780 - 3 Pole Contactors
MARS 780 - 3 pole contactors are designed for demanding applications. The enclosed body design provides quiet operation and improved durability by reducing the intrusion of dust and dirt. Side attachment rails for auxiliary switches (30-60 amp contactors) allow attachment of MARS 780 or Furnas auxiliary switches. Silver-cadmium oxide contacts provide increased contact life when switching inductive loads.
Features: · Large arch window box lugs · SEMS screws or box lugs available on 30 amp contactors · Recessed push to test button (not on 75 and 90 amp contactors) · Enclosed body design · Accepts MARS 780 and Furnas auxiliary switches · Use standard MARS 780 replacement coils · Dual QC coil terminals plus screw terminal for easy termination and
jumper arrangements · Coils - class F insulation · 600 volt rating · Foot print compatible · UL File E96705
61445
61480
3 Pole 30 - 90 Amp
MARS NO.
61430* 61431* 61432* 61433* 61434* 61750 61751 61752 61753 61754 61445 61446 61447 61448 61449 61460 61461 61462 61463 61464 61470 61471 61472 61473 61474 61480 61481 61482 61483 61484 61490 61491 61492 61493 61494
FURNAS NO.
42BF35AJ 42BF35AF 42BF35AG 42BF35AL 42BF35AH
42CF35AJ 42CF35AF 42CF35AG 42CF35AL 42CF35AH 42DF35AJ 42DF35AF 42DF35AG 42DF35AL 42DF35AH 42EF35AJ 42EF35AF 42EF35AG 42EF35AL 42EF35AH 42FE35AJ106 42FE35AF106 42FE35AG106 42FE35AL106 42FE35AH106 42GE35AJ106 42GE35AF106 42GE35AG106 42GE35AL106 42GE35AH106
* For 25 Amp Contactors - Use 30 Amp in Place of 25Amp
FLA
LOCKED ROTOR AMPS
240V
480V
600V
NON INDUCTIVE
AMPS
COIL VOLTS
1 PH 240V
24
120
30
180
150
120
40
208-240
3 HP
277
480
24
120
30
180
150
120
40
208-240
3 HP
277
480
24
120
40
240
200
160
50
208-240
5 HP
277
480
24
120
50
300
250
200
63
208-240
5 HP
277
480
24
120
60
360
300
240
75
208-240
7.5 HP
277
480
24
120
75
450
375
300
94
208-240
15 HP
277
480
24
120
90
540
450
360
120
208-240
15 HP
277
480
HORSEPOWER
3 PH
240V
480V
7.5 HP
10 HP
7.5 HP
10 HP
10 HP
15 HP
15 HP
20 HP
20 HP
25 HP
25 HP
40 HP
30 HP
50 HP
TERMINATION 600V
15 HP
Screw Type
15 HP
Box Lug
20 HP
Box Lug
25 HP
Box Lug
30 HP
Box Lug
40 HP
Box Lug
50 HP
Box Lug
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
C13
COMPONENTS
MARS 780 Definite Purpose Contactors
30-40A 1 Pole with Shunt
30-40A 2 Pole
30-40A 2* Pole & 3 Pole
Note - 2* Pole is a 3 pole body with center contacts removed.
MARS NO.
FLA
POLES
A
B
C
D
D1
E
MTG SCREW G MAX WIRE SIZE
61320-61323
30
1
3.19
1.97
2.46
1.5
1.77
1.61
10
8
61720-61724 61730-61734
30-40
1
3.19
1.97
2.46
1.5
1.77
1.61
10
4
61345-61349
30
2
3.19
1.97
2.46
1.5
1.77
1.61
10
8
61745-61749 61755-61759
30-40
2
3.19
1.97
2.46
1.5
1.77
1.61
10
4
61430-61434
30
3
3.69
2.38
2.87
3.13
3.25
1.98
10
8
61750-61754 61445-61449
30-40
3
3.69
2.38
2.87
3.13
3.25
1.98
10
4
61425-61428 61440-61443
30-40
2(at 3P)*
3.69
2.38
2.87
3.13
3.25
1.98
10
4
C14
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com
COMPONENTS
MARS 780 Definite Purpose Contactors
50-60A 3 Pole
75-90A 3 Pole
MARS NO.
61460-61464 61470-61474
61480-61484 61490-61494
FLA
POLES
A
B
C
D
D1
E
MTG SCREW G MAX WIRE SIZE
50-60
3
4.04
2.87
3.11
3.13
3.25
2.24
10
2
75-90
3
5.02
3.5
4.39
4.43
4.63
2.87
10
1/10
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
C15
COMPONENTS
MARS 780 Definite Purpose Contactors
Renewal Parts and Accessories
· Snap on side mounted auxiliary switches · Replacement coils
61614
61616
61623
61625
61679
61692
61684
Auxiliary Switches
MARS NO.
FURNAS NO.
DESCRIPTION
CONTACTOR F.L.A.
61610
49ACRO
1 NO
61611
49ACRC
1 NC
61612
49ACR6
1 NO- 1 NC
61613
49ACR7
2 NO
30 - 60
61614
49ACR8
2 NC
61615
49D36098001
SPDT
61616
49D36098003
DPDT
61623
-
SPDT
61624
-
1 NO
75-90
61625
-
1 NC
USED ON
61320-61324 61720-61724 61730-61734 61345-61349 61745-61749 61755-61759 61430-61434 61750-61754 61445-61449 61425-61428 61440-61443 61460-61464 61470-61474
61480-61484 61490-61494
MARS 780 Contactor Coil Characteristics
Contactor Series
Inrush VA Sealed VA Sealed Watts
1 Pole with shunt 30 to 40 amp
40
7.5
2.5 - 3.5
2 Pole - Small Body 30- 40 Amp
45
8
2.5 - 4.0
2 Pole Large Body 30- 40 Amp
90
16
3.5 - 5.0
3 Pole 30 - 40 Amp
90
16
3.5 - 5.0
3 Pole 50 - 60 Amp
145
20
5.0- 7.0
3 Pole 75 - 90 Amp
235
32
10.0 - 12.0
MARS 780 Replacement Coils
MARS NO.
FURNAS NO.
CONTACTOR SIZE
61679
-
61680
-
61681
-
3 Pole 30-40 Amp
61682
-
61683
-
61684
-
61685
-
61687
-
3 Pole 50-60 Amp
61690
-
61691
-
61692
-
61693
-
61694
-
3 Pole 75-90 Amp
61695
-
61696
-
C16
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
COIL VOLTAGE
24V 120V 208-240V 277V 480V 24V 120V 208-240V 277V 480V 24V 120V 208-240V 277V 480V
®
marsdelivers.com
COMPONENTS
Furnas NEMA Contactors & Starters
Furnas NEMA Contactors & Starters
Application:
NEMA heavy duty contactors and starters are designed for across the line starting of 3 phase motors. Typical applications include cooling towers, refrigeration equipment, and commercial HVAC. NEMA contactors provide the switching (on/off) function. NEMA starters consist of a NEMA contactor with the addition of motor protection via a solid state overload relay which includes phase loss protection.
T p
()
100.0 10.0
958A Trip Curve with Tolerance
min nom max
1.0
Standard NEMA Contactor Features:
· Rugged industrial design epoxy encapsulated coil seals out moisture, promotes heat transfer, and resists electrical, mechanical, and thermal stresses. The 45 degree wedge action contacts reduce tracking and provide faster arc quenching. The resulting selfcleaning and reduced contact bounce mean cooler operation and longer life for the large silver cadmium oxide contacts
· Dual Voltage Coils 120/240 VAC is standard 24 VAC and 240/480 VAC are available as accessories
· Easy coil access. Top mounted coil requires no tools to change
Standard NEMA Starter Features:
· NEMA Contactor
· True phase loss protection Trips within 3 seconds and is self protected from short circuits
· High accuracy +/- 2% repeat trip accuracy
· Self powered requires no hard wiring or separate power source
· Heaterless construction minimizes energy costs. Does not require the use of complicated heater charts. Simply set the dial on the overload relay to the motor F.L.A.
· Overload trip class 20
61770
61811
0.1 100%
200%
300%
400%
500%
Current, % of dial setting
600%
700%
800%
NEMA Starters
MARS NO.
SEIMENS NO.
61770 14CUC32BA
61771 14CUD32BA
61772 14DUC32BA
61774 14DUD32BA
61775 14DUE32AA
61776 14DUE32BA
61777 14ESG32BA
61779 14FUF32AA
61780 14FUF32BA
61782 14HUG32BA
61783 14HUG32AA
NEMA SIZE
0 0 1 1 1 1 1-3/4 2 2 3 3
AMP RATING
18 18 27 27 27 27 27 45 45 90 90
HORSEPOWER
200V
230V
460V
2
2
5
3
3
-
2
2
5
3
3
10
7-1/2
7-1/2
-
7-1/2
7-1/2
-
10
10
15
-
-
15
10
15
25
25
30
50
25
30
50
OVERLOAD COIL RANGE VOLTAGE
ENCL.
2.5-10A 120/240 NEMA 1
9-18A
120/240 NEMA 1
2.5-10A 120/240 NEMA 1
9-18A 120/240 NEMA 1
13-27A 120/240 Not Included
13-27A 120/240 NEMA 1
10-40A 120/240 NEMA 1
13-52 A 120/240 Not Included
22-45A 120/240 NEMA 1
45-90A 120/240 NEMA 1
45-90A 120/240 Not Included
NEMA Contactors
MARS NO.
SEIMENS NO.
61811 40DP32AA
61813 40FP32AA
NEMA SIZE
1
2
AMP RATING
27
45
200V 7-1/2 10
HORSEPOWER 230V
7-1/2
15
460V 10 25
COIL VOLTAGE
120/240
120/240
ENCL.
Not Included Not Included
Parts & Accessories for Starters & Contactors
MARS NO.
SEIMENS NO.
DESCRIPTION
NEMA SIZE
61652
75D73070J
Coil 24VAC
0-2.5
61650
75D73070A
Coil 120/240V
0-2.5
61653
75D73070C
Coil 240/480V
0-2.5
61654
75D73070D
Coil 208V
0-2.5
61656
75CF14
Replacement Contact Kits*
0
61657
75DF14
Replacement Contact Kits*
1
61658
75FP14
Replacement Contact Kits*
2
61659
49AB10
N.O. Auxiliary Contact
0-3
61660
49AB01
N.C. Auxiliary Contact
0-3
* Replacement contacts are sold in kits that will re-build 1 power pole. For example: Use (3) 75CF14 contact kits to re-build a 3 pole device.
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
C17
COMPONENTS
GE Definite Purpose Contactors
Model 453 Definite Purpose Contactors
The compact models feature universal mount bases, taped coils, and combination phillips/ slot head screws. The GE compact design features "no burn" coil design. This self-protecting coil meets the Trane specification. 453 GE compact design contactor meets ARI 780. Some other manufacturer's economy model compact contactors do not meet this rigorous spec.
Features: · Compact overall size · Combo phillips/slothead screws/hexhead on 30 amp · Universal mount base
Specifications: CR453C Compact, 30A, 40A, 1-Pole Plus Shunted Pole & 2-Pole
FULL LOAD AMPS
RESISTIVE AMPS PER POLE
LOCKED ROTOR AMPS
SINGLE PHASE, 50/60 HZ
240/277V
480V
600V
30
40
180
150
120
* Ratings shown are for 1-phase, 2-pole.
MARS NO.
FLA
13101
30
RESISTIVE RATING
PER POLE
40
POLES 1-1/2
VOLTAGE 24
GE MODEL 453CC3HAAAM
HEIGHT 2-9/16
13101
POLES 1 + Shunt
DIM. WIDTH
2
DEPTH 3-1/4
Universal Enclosure
Universal Contactor Enclosure
The MARS 92680 Universal Contactor enclosure will fit contactors from 20 to 40 amp. This enclosure will also fit the new smaller frame ACC533 and ACC633 contactors. Each enclosure comes with all the necessary mounting screws.
MARS NO. 92680
MFG. PART NO. AHK425A
DESCRIPTION Universal Contactor Enclosure
C18
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com
COMPONENTS
MARS Definite Purpose Contactors
MARS Definte Purpose Contactors
MARS definite purpose contactors are designed for use on refrigeration, air conditioning, and electric heating systems. They are available in one pole with shunt (one and one half pole) configurations, from 30 thru 40 amps. MARS brand definite purpose contactors are also available in 2 pole models (30 and 40 amp) and 3 pole models (30 through 75 amp). The universal mounting base allows replacement of most contactor brands. Straight-thru wiring and small size speeds installation.
Features:
· Used in air conditioning, heating and refrigeration
· Box lug terminations speed installation · Universal mounting base
· Contact cover and enclosed coils reduce dirt and insect intrusion
· Compact design · Silver-Cadmium contacts
Specifications: · Meets ARI 780/790 requirements · cULus Approval
Auxiliary Switches
MARS NO
DESCRIPTION
61623 61624 61625
SPDT 1 NO 1 NC
· 1,000,000 Cycle mechanical life
USED ON
All 3 Pole 910
91311-13
91631-33, 91731-33
MARS NO. FLA
91311
91312
30
91313
91315
91316
30
91317
91321
91322
30
91323
91325
91326
30
91327
91331
91332
30
91333
91335
91336
30
91337
91411
40
91421
91422
40
91423
91431
91432
40
91433
91531
91532
50
91533
91631
91632
60
91633
91731
91732
75
91733
POLES 1 Pole w/Shunt 1 Pole w/Shunt
2 2 3 3 1 Pole w/Shunt 2 3 3 3 3
LOCKED ROTOR AMPS 240 277 480 600
RES. AMPS
180 180
40
180 180
40
180
-
150 120
40
180
-
150 120
40
180
-
150 120
40
180
-
150 120
40
240 240
-
-
50
240
-
200 160
50
240
-
200 160
50
300
-
250 200
63
360
-
300 240
75
450
-
375 300
94
COIL VOLTS
24 120 208/230 24 120 208/230 24 120 208/230 24 120 208/230 24 120 208/230 24 120 208/230 24 24 120 208/230 24 120 208/230 24 120 208/230 24 120 208/230 24 120 208/230
TERMINATION Screw Type Box Lug Screw Type Box Lug Screw Type Box Lug Box Lug Box Lug Box Lug Box Lug Box Lug Box Lug
1 PH 240
3 HP 3 HP 5 HP 5 HP 7.5 HP 15 HP
HORSEPOWER
3 PH
240
480
-
-
-
-
-
-
-
-
7.5 HP
10 HP
7.5 HP -
10 HP -
10HP
15 HP
15 HP
20 HP
20 HP
25 HP
25 HP
40 HP
600 -
15 HP 15 HP
20 HP 25 HP 30 HP 40 HP
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
C19
COMPONENTS
Magnetic Line Contactors
30 Amp Two Pole Contactors
The MARS Series 180 contactors are designed primarily to replace contactors used in air conditioning and electric heating to control blower motors. In addition they are used to switch pumps and computer power supplies. Replace General Electric Contactors and other manufacturers including WR, Essex/RBM and Honeywell.
Features: · Replace all 3ARR8, 9, 27, and 28 General Electric contactors · Replace WR, Essex/RBM and Honeywell · Instructions and cross reference chart included · Non-positional · UL and CSA listings available
18001
Cross Reference
GEMLINE
HONEYWELL NO.
MC11
R850B1146
MARS REPLACEMENT
18001
COIL schematic
KIT 93103 Sold Seperately
4 SCREWS & 4 TERMINALS
MARS NO.
18001
93103
DESCRIPTION
30 Amp 2 Pole Magnetic Line Contactor
Push-On Terminals Adapters and Screws.
FULL LOAD AMPS
RESISTIVE AMPS
30
30
LOCKED ROTOR AMPS
120
-
-
-
COIL VOLTAGE
24
-
POLES 2 -
COIL VOLT
24
-
PICK-UP HOT
20.5
-
MAX COLD
19.2
-
Fan Centers
MARS Relay/Transformer Fan Control Centers
Schematic: MARS series 240
fan centers provide
Black Common
Black Common
Purple Common Black Common
White
Black Common
White
Purple Common
Black Common
Black Common White 120V
Red 208V Orange 240V
convenient low
voltage control of
one and two speed
fan motors and
Coil
Coil
Coil
Yellow NC Red NO
Yellow NC Red Yellow NO
Brown NC Red NO
auxiliary circuits in
heating, cooling, or
heating/cooling
applications. Each
MARS fan center is
a reliable, compact unit consisting of a
24010
24012
24013
24 volt control transformer and a plug-in switching relay mounted on a 4" square electrical junction box cover.
All line voltage connections are made inside the box with color coded pre-stripped leads. Low voltage
connections are made at a convenient terminal board mounted to the transformer.
Brown NC Red NO
24010
Features: · Choice of SPDT, SPNO / SPNC or
DPDT relay switching options · UL 1585 40VA transformer · Color coded leads · Low voltage terminal board · Mounts directly to 4" electrical box · 50/60 Hertz
40VA 3/4 HP
MARS NO.
24010 24012 24013
TRANSFORMER
PRIMARY
SECONDARY
VOLTAGE CONNECTIONS VOLTAGE CONNECTIONS
120/208/ Color coded 240 leads, pre-stripped
24V
Terminal board with 5 screw terminals
120
Color coded leads, pre-stripped
24V
Terminal board with 5 screw terminals
120
Color coded leads, pre-stripped
24V
Terminal board with 5 screw terminals
RELAY
DPDT SPNO/ SPNC SPDT
CONTACT RATINGS
120V AC (AMPS)
240V AC (AMPS)
FULL LOCKED FULL
LOCKED
LOAD ROTOR LOAD
ROTOR
13.8
82.8
6.9
41.4
13.8
82.8
6.9
41.4
13.8
82.8
6.9
41.4
C20
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com
COMPONENTS
Transformers
MARS Control Transformers NEMA Class II Open Construction
MARS compact open construction transformers are less than 2-1/4" in height. This makes them ideal as replacements within existing equipment.
MARS control transformers are available with various outputs and voltages for special applications.
50351
Application:
Provide power source for control circuit for air conditioning, heating, or refrigeration systems.
Features: · UL class 2 recognized · Low heat rise · Primary color coded leads · Secondary color coded leads,
or 1/4" male quick connects · Foot-mount
50354 50364
Foot-Mount Open Construction
MARS NO.
VA RATING
HZ
PRIMARY
SECONDARY
VOLTAGE CONNECTIONS VOLTAGE CONNECTIONS
50351
20 50/60
120
Color coded leads
24
Color coded leads
50352
40 50/60
120
Color coded leads
24
Color coded leads
50353
40 50/60 208/240
Color coded leads
24
Color coded leads
50354
40
50/60 120/208/240
Color coded leads
24
Color coded leads
50355*
40
60
120
Color coded leads
12/24
Color coded leads
50350
20
50/60 120/208/240
Color coded leads
24
Color coded leads
50357
40 50/60
277
Color coded leads
24
Color coded leads
50359(1)
40
50/60 120/208/240
Color coded leads
24/12/2.5
Color coded leads
50308
50
50/60 120/208/240
Color coded leads
24
Color coded leads
* Not UL listed (1) In line fuse protection
Foot-Mount Open Construction With Primary & Secondary Quick Connects
MARS NO.
50362 50364 50363
VA RATING
40 40 40
HZ
50/60 50/60 50/60
PRIMARY
SECONDARY
VOLTAGE 120
120/208/240 208/240
CONNECTIONS
1/4" Male quick connects
1/4" Male quick connects
1/4" Male quick connects
VOLTAGE 24 24 24
CONNECTIONS
1/4" Male quick connects
1/4" Male quick connects
1/4" Male quick connects
MARS Control Transformers NEMA Class II End Bell Type
MARS end bell transformers provide enclosures for the primary and secondary windings, MARS multi-mount models offer three mounting options - Foot, Plate, or Conduit mount.
MARS control transformers are available with various outputs and voltages for special applications.
Application: Provide power source for control circuit for air conditioning, heating, or refrigeration systems.
Features: · UL class 2 recognized · Low heat rise · Primary color coded leads · Secondary color coded leads,
or screw terminals · Multi-mount or plate-mount
50306 50305
50302 50303 50304
50301
50337
Foot-Mount End Bell Type
MARS NO.
50301
VA RATING
HZ
20
60
PRIMARY
VOLTAGE 120
CONNECTIONS
Color coded leads
SECONDARY
VOLTAGE CONNECTIONS
24
Color coded leads
Multi-Mount End Bell Type
MARS NO.
VA RATING
HZ
PRIMARY
SECONDARY
VOLTAGE CONNECTIONS VOLTAGE CONNECTIONS
50302 50303 50304 50306* 50314 50333* 50337
40 50/60
120
Color coded leads
24
Screw terminals
40 50/60 208/240
Color coded leads
24
Screw terminals
40
60
120/208/240
Color coded leads
24
Screw terminals
48
60
277
Color coded leads
24
Color coded leads
50
50/60 120/208/240
Color coded leads
24
Color coded leads
48
50/60 120/208/240
Color coded leads
24/12/2.5
Color coded leads
75
50/60 120/208/240
Color coded leads
24
Color coded leads
* Not UL listed (1) Color coded leads on secondary, (2) Screw terminals on secondary
Plate-Mount End Bell Type
MARS NO.
VA RATING
HZ
PRIMARY
SECONDARY
VOLTAGE CONNECTIONS VOLTAGE CONNECTIONS
50305
40 50/60
120
Color coded leads
24
Screw terminals
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
C21
COMPONENTS
Transformers
MARS Control Transformers NEMA Class II
Hub-Mounted Transformers with Circuit Breakers and Multiple Inputs of 120/208/240/480 VAC
Available either in 50VA or 75VA, these 2 versatile transformers replace Honeywell® AT150F and AT175F. All leads pass through the chase nipple.
· MARS 50319, 50VA, MARS 50372, 75VA
· 3 Way mounting · Four inputs including
120/208/240/480 VAC · UL Recognized
50319 50372
Hub Mount End Bell Type
MARS VA NO. RATING
HZ
50319 50 50/60
50372 75 50/60
PRIMARY
VOLTAGE 120/208/240/480 120/208/240/480
CONNECTIONS
Color coded leads
Color coded leads
SECONDARY
VOLTAGE 24 24
CONNECTIONS
Color coded leads
Color coded leads
MARS Control Transformers NEMA Class II Heavy Duty End Bell Type
MARS control transformers are available with various outputs and voltages for special applications.
Application: MARS heavy duty end bell transformers offer a wide variety of higher VA rated models. These models are the choice when extra power is the solution.
Features: · UL class 2 recognized · 50/60 Hz · Low heat rise · Color coded leads · Foot-mount
50316
50340
Foot-Mount End Bell Type
MARS NO.
VA RATING
HZ
PRIMARY
SECONDARY
VOLTAGE CONNECTIONS VOLTAGE CONNECTIONS
50316
60 50/60 208/240
Color coded leads
24
Color coded leads
50320(1)
75
50/60
120/208/ 240/480
Color coded leads
24
Color coded leads
50324
75 50/60 208/240
Color coded leads
24
Color coded leads
50326
75 50/60
480
Color coded leads
24
Color coded leads
50340*
100
50/60
120/208/ 240/480
Color coded leads
24
Color coded leads
*100 VA does not qualify for NEMA Class II (1) Inline fuse
Foot Mounted Open Construction
MARS NO.
VA RATING
HZ
50339(2) 75 50/60
PRIMARY
SECONDARY
VOLTAGE 480
CONNECTIONS VOLTAGE CONNECTIONS
Color coded leads
120 Color coded leads
(2) UL 506
C22
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com
COMPONENTS
Transformers
MARS Control Transformers NEMA Class II Manual Reset Style
MARS control transformers are available with various outputs and voltages for special applications.
Application: Provide power source for control circuit for air conditioning, heating, or refrigeration systems.
Features: · UL class 2 recognized · Low heat rise · Color coded leads or quick
connect terminals · Foot-mount
50321 50327 50341 50375
Foot-Mount End Bell Type with Manual Reset
MARS NO.
VA RATING
HZ
50327
50
60
50321
75 50/60
50375
75 50/60
50341* 100 50/60
50312
60 50/60
50370
75 50/60
50371
100 50/60
PRIMARY
SECONDARY
VOLTAGE
120/208/ 240/480
120/208/ 240/480
120/208/ 240/575
120/208/ 240/480
120/208/ 240/480
120/277/ 380/575
120/208/ 277/575
CONNECTIONS
Color coded leads
Color coded leads
Color coded leads
Color coded leads
Color coded leads
Color coded leads
Color coded leads
VOLTAGE 24 24 24 24 24 24 24
CONNECTIONS
Color coded leads
Color coded leads
Color coded leads
Color coded leads
Color coded leads
Color coded leads
Color coded leads
* 100VA and higher does not qualify for NEMA Class II
MARS Power Transformers
Application:
Provide 120V power source for air conditioning, heating, or refrigeration systems. MARS power transformers provide dual purpose options -- 120V or 24V secondary with 208V/240V/480V primary connections. Three VA selections offer a true powerhouse!
Features: · Color coded leads · Compact size · Low heat rise
50380
Power Transformers Foot-Mount Open Construction
MARS NO.
VA RATING
HZ
PRIMARY VOLTAGE CONNECTIONS
SECONDARY VOLTAGE CONNECTIONS
50380(1) 50 50381(2) 100
60 208/240/480 60 208/240/480
Color coded leads Color coded leads
120/24 120/24
Color coded leads Color coded leads
(1) Not UL listed (2) UL 506
GE Type Ip Core and Coil Transformers
GE type IP transformers are core and coil units designed for industrial control, panel board, HVAC and general purpose applications. They conform to ANSI C89.2, and are UL listed and CSA certified. These transformers are lightweight, small and designed for minimum mounting dimensions.
Features: · 60 Hz
· Encapsulated thru 500VA
· Control power applications
· UL listed, UL-506 File E2739
· CSA certified, C22.2 Number 66, File 3272
· 50 Hz available on special order basis
50502
top view front view Encapsulated Style Views
Encapsulated
MARS NO.
CONT. KVA
PRIMARY
SECONDARY
A
DIMENSIONS
B
C
D
E
50502 .075 240/480 120/240
4.22 3.29 2.79 2.41
2.50
50504 .150 240/480 120/240
4.67 4.04 3.29 2.66
3.12
50506 .250 240/480 120/240
5.17 4.04 3.29 3.16
3.12
50507 .300 240/480 120/240
5.17 4.04 3.29 3.16
3.12
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
C23
COMPONENTS
JARD Transformers
Hub-Mounted Transformers with Circuit Breakers and Multiple Inputs of 120/208/240/480 VAC
Available either in 50VA or 75 VA, these 2 versatile transformers replace Honeywell® AT150F and AT175F. All leads pass through the chase nipple.
· Model 5041MCB, 50 VA, Model 7541MCB, 75 VA
· Plate mount or foot mount
· Four inputs including 120/208/240/480 VAC
· UL Recognized
44519 44520
Fully Enclosed Junction Box Ready
· Several models with dual voltage output
· Welded laminations for quiet operation
· Conservative heat rise characteristics
· UL 506
44532 44534
44527
44540
MARS NO.
44519
44520
JARD NO.
5041MCB
7541MCB
VA
PRIMARY VAC
SECONDARY VAC
50
120/208/240/480
24
75
120/208/240/480
24
Multi-Mount Transformers Closed Construction, 4" x 4" Plate
· Optional 3-way mounting for maximum flexibility · Safety agency approved · Welded laminations for quiet operation
MARS NO.
JARD NO.
VA
PRIMARY VAC
SECONDARY VAC
44522
4011M
40
120
24
44524
4031M
40
120/208/240
24
44525
5031M
50
120/208/240
24
44526
5032M
48
120/208/240
2.5/12/24
44527
7541M
75
120/208/240/480
24
44528
7541STM
75
120/240/277/575
24
MARS NO. 44532
44533
44534
44535
JARD NO.
VA
5048PC
50
5048STPC
50
10048PC
100
10048STPC
100
PRIMARY VAC
240/480
208/277/575
240/480
208/277/575
SECONDARY VAC 120 120 120 120
Open Construction Foot Mount Wire Leads
MARS NO.
JARD NO.
VA
PRIMARY VAC
SECONDARY VAC
44536
5024P
50
208/240
120/24
44538
7524P
75
208/240
120/24
C24
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com
COMPONENTS
JARD Foot Mount Transformers
44518
44504
44513
44517
JARD # 4031VM Includes 2 Brackets
Open Construction, Wire Leads
· Safety agency approved
MARS NO.
44501 44502 44503 44504 44505 44507 44508 44509 44510
JARD NO.
2031F 4011F 4021F 4031F 4032F 40271F 5031F 5032F 7531F
VA
PRIMARY VAC
20
120/208/240
40
120
40
208/240
40
120/208/240
40
120/208/240
40
277
50
120/208/240
50
120/208/240
75
120/208/240
SECONDARY VAC
24 24 24 24 2.5/12/24 24 24 2.5/12/24 24
Closed Construction With Circuit Breaker
· All models feature a UL recognized manual reset circuit breaker · Safety agency approved
MARS NO.
44511 44512 44513 44514 44515 (1)
JARD NO.
5041C 6041C 7541C 7541STC 10041C
VA
PRIMARY VAC
SECONDARY VAC
50
120/208/240/480
24
60
120/208/240/480
24
75
120/208/240/480
24
75
120/277/380/575
24
100
120/208/240/480
24
(1) Not UL, UL506
Closed Construction Quick Connect
MARS NO.
44517
JARD NO.
VA
4031OEM
40
PRIMARY VAC
120/208/240
SECONDARY VAC 24
Versatile 3-Way Mounting
MARS NO.
JARD NO.
VA
PRIMARY VAC
44518
4031VM
40
120/208/240
SECONDARY VAC 24
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
C25
COMPONENTS
MARS Surge Protection Device
MARS Side Open Disconnect Boxes with Internal Surge
MARS Disconnect with integrated surge protector provides a unitized design for quick and clean installation. The metal weatherresistant enclosure provides additional robustness and security. MARS Surge Protectors provide the performance necessary to protect critical components in high efficiency mini-split and unitary HVAC equipment.
Features:
Specifications Disconnect:
· Side open disconnect · Integrated internal surge protector · Thermally Protected MOV's
· Single phase 240V · 10,000 Amp rating · NEMA 3R enclosure
· Metal-weather resistant enclosure · External - Green & Red LED
Status Indicators · cULus rating
· Weather proof enclosure
· Available in fused and non-fused
· 3 Year Warranty
· $7,500 Connected Equipment Warranty
Surge Protector Ratings: · 120/240V Single (Split)
Phase 50/60Hz · Short Circuit Current Rating
o 22,000 Amps · MCOV L-N 150V / L-L 330V · Voltage Protection Rating
o L-N 800V / L-L 1200V · UL 1449 4th Edition · Type 1 or 2 Surge
Protection Rating
Protects: · Compressors · Heat Pumps · Ideal for
Ductless System · Inverter Boards · ECM Motors · Control Boards · Transformers · Relays · Sensors
MARS NO. 83915 83916 83917
MARS NO. 83914
DESCRIPTION
60 Amp Non-Fused 30 Amp Fused 60 Amp Fused
VOLTAGE
120/240 120/240V 120/240V
WIRE CONFIGURATION
L1,L2,L/N-G
L1,L2,L/N-G
L1,L2,L/N-G
SPD TYPE 1 or 2
1 or 2
1 or 2
MCOV
150/300 150/300 150/300
ENCLOSURE
NEMA 3R, Rainproof NEMA 3R, Rainproof NEMA 3R, Rainproof
UL 1449 4TH EDITION
cULus
cULus
cULus
DESCRIPTION Replacement Surge Module
83914
83915
MARS HVAC Surge Protective Device
The MARS SPD is designed to protect your HVAC equipment from power spikes, surges and transients. Power spikes and surges can damage compressors, control boards, sensors and ECM motors resulting in costly repairs and down time. The MARS SPD utilizes Thermally Protected MOV technology to provide safe and reliable surge protection.
120/240 VAC Single Split Phase SPD for use on a variety of HVAC Equipment
Protects:
· Compressors · ECM Motors
· Heat Pumps
· Control Boards
· Ideal for
· Transformers
Ductless Systems · Relays
· Inverter Boards · Sensors
Features:
LED Protection Status Indicators
Meets all UL 1449 4th Edition Standards
· Easy Installation to Disconnect
· Weatherproof 4X Enclosure
· 18" Pre-stripped Leads · Green & Red LED Status Indicators · Thermally Protected MOVs
18 in. 10 Gauge Leads
· 120/240V Single (Split) Phase 50/60Hz
· Short Circuit Current Rating o 22,000 Amps
· MCOV L-N 150V / L-L 330V · Voltage Protection Rating
o L-N 800V / L-L 1200V · UL 1449 4th Edition · Type 1 or 2 Surge Protection Rating · 3 Year Warranty · $7,500 Connected
Equipment Warranty
1/2 inch x 20 Threaded Nipple (weatherproof and UV resistant)
Unmatched Surge Protection Ratings
Type 4x Weatherproof Enclosure
MARS Surge Protective devices utilize Thermally Protective MOV surge technology
MARS NO.
83905
VOLTAGE
WIRE CONFIGURATION
120/240 L1,L2,L/N-G
SPD TYPE
1 or 2
MCOV
ENCLOSURE
UL 1449 4TH EDITION
150/300 Type 4X
cULus
MARS HVAC Surge Protective Device
The MARS 83904 SPD is designed specifically for 120V furnace and air handler applications. The furnace and air handler contain components that must be protected from surges such as, ECM motors, Control Boards, Transformers. The MARS Surge utilizes thermally protected MOV technology for safe and reliable protection of equipment. The 120V Surge Device is easy to install with only 2 wires to connect.
Protects: · Ideal for 120V Ductless Systems · Furnace & Air Handlers · Inverter Boards · ECM Motors · Control Boards · Transformers · Relays · Sensors
Features: · Easy 2 Wire Installation · 10" Pre-stripped Leads · Green LED Status Indicator · Thermally Protected MOVs · 120V Single Phase 50/60Hz · Short Circuit Current Rating
o 10,000 Amps · MCOV L-N 150V · Voltage Protection Rating
o L-N 700V · UL 1449 4th Edition · Type 1 or 2 Surge Protection Rating · 3 Year Warranty · $7,500 Connected Equipment
Warranty
120 VAC Single Split Phase SPD
LED Protection Status Indicator Meets all UL 1449 4th Edition Standards
Unmatched Surge
Protection Ratings
8 in. 12 Gauge
Leads
1/2 inch x 20 Threaded Nipple (weatherproof and UV resistant)
MARS Surge Protective devices utilize Thermally Protective MOV surge technology
MARS NO.
83904
VOLTAGE
WIRE CONFIGURATION
120
L1,L2,L/N-G
SPD TYPE
1 or 2
MCOV
ENCLOSURE
UL 1449 4TH EDITION
150
Type 2
cULus
C26
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com
COMPONENTS
MARS Surge Protection Device & Condensate Pumps
MARS HVAC Surge Protective Device
The iSPD (Intelligent Surge Protection Device) offers comprehensive protection for your HVAC equipment.
The MARS 83907 Surge Protection Device is designed to provide maximum compressor protection from harmful power surges, transients and over-voltages utilizing the latest Thermally Protected MOV technology.
In addition, the modules microprocessor technology monitors line voltage to protect the compressor from starting or running during "brown outs" and low line voltage. The module also monitors refrigerant temperatures to identify coil freeze-up and or low refrigerant issues.
If the module detects a low voltage or refrigerant issue the compressor is shut down. The module will automatically reset when specified operating parameters are restored and determined to be stable.
In the event of diminished surge protection or failure, the compressor will not be allowed to start until the module is replaced.
Protects the Following Equipment and Components:
· Compressors
· Control & Defrost Boards
· Heat Pumps
· Reversing Valves
· Sensors & Relays · ECM Motors
· Transformers
Plus: · Low Voltage Protection · Coil Freeze-up / Low Refrigerant Detection · Short Cycle Guard
Features: · Easy installation to disconnect box · Weatherproof 4X enclosure · Fits 1/2" knockouts · Green & Red LED status indicators · Thermally protected MOV's · 240V single phase 50/60Hz · Max surge current 10,000 A · Max continuous over voltage
° L-N 150V / L-L 300V · Voltage protection rating
° L-N 700V / L-L 1000V · 3 Year warranty · $7,500 Connected equipment warranty
MARS NO.
83907
VOLTAGE 240
WIRE CONFIGURATION
L1,L2,L/N-G
SPD TYPE
1 or 2
MCOV 150/300
ENCLOSURE Type 4X
UL 1449 4TH EDITION
cULus
240 VAC Single Split Phase
SPD for use on a variety
of HVAC Equipment
Microprocessor
Based Controls
18 in. 10 Gauge Leads
LED Status Indicators
Meets all UL 1449 4th Edition Standards
1/2 inch x 20 Threaded Nipple
Unmatched Surge Protection Ratings Type 4x Weatherproof Enclosure UV Resistant
MARS Surge Protective devices utilize Thermally Protective MOV surge technology
MERCURY Mini-Split Pump Kit
Mercury pumps are designed for wall mount ductless mini-split AC units and evaporator coil applications. Pump mounting is flexible and can be installed in the evaporator unit, duct channel or above the unit in the ceiling.
Kit Includes Pump, reservoir with safety switch, adapter, cable ties, tubing to connect pump and reservoir, velcro mounting tape for ease of installation and service.
Features: · Self priming, fully potted pump · Silent operation · 26 Ft lift · 2.6 Gallon per hour condensate capacity · Standard safety switch provides connections for unit shut down and alarm. · For use with equipment up to 25,000 BTU's
MARS NO.
21791
VOLTAGE 115/220V 60Hz
HEAD GPH
0 FT.
13 FT.
20 FT.
26 FT.
2.64
2.38
1.59
0.92
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
C27
COMPONENTS
Condensate Pumps
MARS Condensate Pump - 24' Lift
MARS Low Profile 22' Pump
MARS new line of medium condensate pumps are designed to out-perform the competition while providing quiet operation and reliability.
The MARS pump design couples industry leading performance with the installation flexibility and features you need to get the job done.
The quick release silicone check
valve allows for quick and efficient servicing without the need to
21780
remove the condensate line.
The integrated safety switch can
be wired for equipment shut down or directly to a high level alarm.
Features: · 24 foot lift
RELAY Y GWR
· 125 gph
· 0.5 gal reservoir
· Patent pending, quick release check valve
· Field serviceable "duck bill" check valve · Rubber isolation feet
TWO BLUE LEAD
WIRES
Y GWR
· Drip proof housing design
THERMOSTAT
· Solid float
· Integrated safety switch 250 volt and float switches
· ABS and stainless steel construction
MARS NO. 21780 21781 21782 21783
DESCRIPTION
115 V, 60 Hz, 0.91 Amps, 71 Watts 6' Cord, 3/8" Check Valve, Safety Switch Medium Reservoir
115 V, 60 Hz, 0.91 Amps, 71 Watts 6' Cord, 3/8" Check Valve, Safety Switch 20' Tubing, Medium Reservoir
230 V, 60 Hz, 0.6 Amps, 75 Watts 6' Cord, 3/8" Check Valve, Safety Switch Medium Reservoir
230 V, 60 Hz, 0.6 Amps, 75 Watts 6' Cord, 3/8" Check Valve, Safety Switch 20' Tubing, Medium Reservoir
Gallons Per Hour Pump Performance Comparison Chart
FOOT LIFT
1
5
10
15
20
24
MARS
125
98
74
70
43
7
Comp. 1
84
75
60
42
10
0
Comp. 2
117
98
70
58
11
0
Comp. 3
105
95
73
36
0
0
Specifications: Performance-Gallons Per Hour @ Height In Feet
MODEL NO.
1
5
10
15
20
24
21780
125
98
74
70
43
7
21781
125
98
74
70
43
7
21782
139
119
70
50
28
7
21783
139
119
70
50
28
7
Check Valve Replacement
MARS NO.
DESCRIPTION
21787 Check Valve Replacement Kit
21787
Features:
· Low profile pump · Compact design · Integrated safety switch · Quick service check valve · Drip proof housing · Class leading performance
21784
MARS NO. 21784 21785
DESCRIPTION
115 V, 60 Hz, 1.07 Amps, 67 Watts, Low Profile, 22' Lift 6' Cord, 3/8" Check Valve, Safety Switch Medium Reservoir
230 V, 60 Hz, 0.53 Amps, 68 Watts, Low Profile, 22' Lift 6' Cord, 3/8" Check Valve, Safety Switch Medium Reservoir
MARS 16' Pump
Features:
· 16' lift pump · Whisper quiet · 1/2 gal reservoir · Rubber isolation feet · Quick service check valve · Class leading performance
21786
MARS NO. 21786
DESCRIPTION
115 V, 60 Hz, 0.75 Amps, 49 Watts, 16' Lift 6' Cord, 3/8" Check Valve, Safety Switch Medium Reservoir
MODEL NO. 21780 21781 21782 21783 21784 21785 21786
LENGTH 10.25 10.25 10.25 10.25 10.25 10.25 10.25
DIMENSIONS WIDTH 5.125 5.125 5.125 5.125 5.04 5.04 5.125
HEIGHT 6.375 6.375 6.375 6.375 5.28 5.28 6.375
Condensate Pump vs. Competition
FEATURE
MARS COMP. 1
24 ft. Lift
l
Motor Corrosion Protection
l
Drip Proof Motor Housing
l
l
Drip Proof Motor & Switches
l
Vibration Absorbing Rubber Feet
l
l
Side Mount
l
l
Quick Release Check Valve
l
l
Internal Safety Switch
l
Solid Float
l
l
COMP. 2
l l l
COMP. 3 l l l
C28
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com
COMPONENTS
MARS Start Assists
MARS AllStartTM Hard Start Device
The MARS AllStartTM is a two wire hard start device designed to provide maximum starting torque for single phase PSC and CSIR compressors up through 10HP. The MARS AllStartTM recycles instantly for maximum convenience on troublesome hard start jobs.
Independent testing has
determined that the MARS
AllStartTM provides more starting torque than other competitive
32708
models, and this results in quicker
starts. Test results on a range of
head pressures from 166 to 300 PSI indicate that the MARS AllStartTM
started the test compressor in an average of 21.7% less time than the
leading competitor! More available starting torque means less time to
get problem compressors started.
MARS offers the largest assortment of refrigeration and air conditioning compressor starting components. When the proper starting relay and capacitor combination is a must, they are available from MARS. When getting a problem compressor started in the field "NOW" is the job, rely on the new MARS AllStart.TM
Features: · Maximum starting torque! · More than 20% faster starts! · Easy two wire installation
STARTING TIME COMPARISON (least is best)
350 300
MARS ALLSTART
LEADING COMPETITOR
250
· Recycles instantly
200
· Individually packaged with wiring instructions
166 205 225 250 275 300 Head Pressure In PSI
SUPPLIER KICKSTART
PART NO.
MARS REPLACEMENT
TO5
32708
SUPCO
SPP8
32708
WATSCO
WSX-1
32708
Time In Milliseconds COMPRESSOR LEADS
WHITE BLACK
RED
MARS Combination Starters
The MCS is a combination start relay, start capacitor, and motor overload. It is designed to replace those components on a 115 volt single phase refrigeration compressor installed on a capillary tube system.
The MCS is factory wired and comes with a connection diagram on the product label for maximum convenience.
Features: · Maximum starting torque! · More than 20% faster starts! · Easy two wire installation · Recycles instantly · Individually packaged with
wiring instructions
SUPPLIER GEMLINE ROBERTSHAW SUPCO
PART NO.
HS 410 HS 810
600-410 600-810
RCO 410 RCO 810
MARS REPLACEMENT
32741 32781
32741 32781
32741 32781
32741
COMMON
START
RUN
BLACK POWER BLACK
MARS NO. 32741 32781
MODEL NO. MCS 41 MCS 81
H.P. 1/4 TO 1/3 1/12 to 1/5
VOLT MAX. 115V 115V
MARS NO. 32708
MODEL NO. AllStart
H.P. 1/2 to 10
VOLT MAX. 115-277V
MARS Motor Torque Multiplier
The MARS MTX 100, MTX 200 and MTX 300 motor torque multipliers feature a combination PTC solid state device, and start capacitor in one compact unit.
The MTX 100 is designed for use on PSC motors and compressors up to 5HP, 277V maximum; the MTX 200 is designed for use on PSC motors and compressors up to 10HP, 277V maximum; and the MARS MTX 300 is designed for use on PSC motors & compressors from 1-1/2 up to 10HP, 115-230V. These units are easily installed by connecting the two leads from the MTX unit to the motor run capacitor terminals.
Features: · Totally solid state integrated design · Fast, easy two wire installation · Three mounting options; clip, screw, or
capacitor bracket · Individually packaged
SUPPLIER PART NO.
GEMLINE ROBERTSHAW
SUPCO
HS 600 HS 650
600-052 600-057
SPP5 SPP6
MARS REPLACEMENT
32701 32702
32701 32702
32701 32702
32701
MARS NO. 32701 32702
MODEL NO. 100 200
H.P. 1/2 to 5 1/2 to 10
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
32702
VOLT MAX. 277V 277V
C29
COMPONENTS
MARS Start Assists
MARS 3 Wire Hard Start Kits
MARS 3 Wire Hard Start Kits provide the additional starting torque required for quicker compressor starts in systems using higher pressure refrigerants. Improved starting performance extends compressor life and minimizes potential refrigerant contamination due to overheated compressor windings. MARS Hard Start Kits also improve system life and performance by reducing undue overload stress on contactors and run capacitors. If your system is slow to start, MARS has a Hard Start Kit to fit your application.
Features: · Start relay made in the USA
and approved by all compressor manufacturers. · Start capacitor made in Mexico · 30% faster starts · 3 wire design ensures proper "drop-out" · Extends life of compressor · Kit contains mounting hardware
MARS 2 Wire Hard Start Kits
MARS 2 Wire Hard Start Kits provide quick and easy installation on the job-site with only 2 connections. 2 Wire Hard Starts provide the additional starting torque for quicker compressor starts and improves compressor. MARS Hard Start kits also improve system life and performance by reducing undue overload stress on contactors and run capacitors.
If your system is slow to start, MARS has a Hard Start Kit to fit your application.
Features:
· Start relay made in the USA and approved by all compressor manufacturers.
· NGM Start Capacitor is approved by all major HVAC manufacturers
· 30% faster starts
· Extends life of compressor
· 2 wire design speeds installation
· Kit contains mounting hardware
Cross Reference
MARS NO.
5-2-1 (CPS)
32715 32716 32717
CSR U1 CSR U2 CSR U3
MARS NO. 32715
32716
32717
VOLTS
208-230/240 208-230/240 208-230/240
Supco
3W1 3W2 3W3
Packard (2 wire)
TQS1 TQS2
Diversitech (2 wire)
HSK5 HSK1
DESCRIPTION
3 Wire Hard Start 1 to 3 Ton 3 Wire Hard Start 3.5 to 5 Ton 3 Wire Hard Start 4 to 5 Ton
Cross Reference MARS NO. 32713 32714
KickStart TO-5 KS-1
MARS NO. 32713
32714
VOLTS
208-230/240 208-230/240
Packard (2 wire) TQS1 TQS2
Diversitech (2 wire) HSK5 HSK1
DESCRIPTION
2 Wire Hard Start 1 to 3 Ton 2 Wire Hard Start 3.5 to 5 Ton
C30
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com
COMPONENTS
MARS General Purpose Switching Relays
For Motor Starting Circuits up to One Horsepower
Features:
· Replace Potter & Brumfield PR series, Deltrol, Guardian, Magnacraft, etc.
· Plastic enclosed coil minimizes damage, resists dirt and moisture
· 5/16" diameter silver contacts for long life
· Tough phenolic base
· Reinforced screw terminals
· UL and CSA listings available
DPST-NO
DPDT with auxiliary
MARS NO.
P & B SERIES
CONTACTS ARRANGEMENT
AMP
COIL COIL RES. VOLTAGE IN OHMS
NOM. POWER
43008 PRD7AY0
DPST-NO
25
120
290
9.8VA
43014 PRD11AY0
DPDT
25
120
290
9.8VA
Cross Reference Information
POTTER & BRUMFIELD
MARS NO.
PR7AY0-120V
43008
PR11AY0-120V
43014
DETROL NO. 20240-83D 20241-83D
MARS NO. 43008 43014
Replacement Relay for Fan Control Centers
Provides quick and easy plug-in installation to restore like new operation without replacing the entire fan center. The universal relay will cover all MARS fan centers and many competitive brands.
90340
MARS NO.
90340
USED ON 24010, 24012, 24013
DESCRIPTION DPDT universal plug-in replacement relay
2-Pole Air Conditioning Relays
The MARS Series 903 switching relays are intended for many applications in air conditioning, refrigeration, and heating. Other uses include general purpose switching in appliances, fan controls, and vending machines. Our relays are available in 24, 110/120, and 208/240 coil voltages with various combinations of power and pilot duty contacts.
90340
Features: · Replaces Honeywell and White-Rodgers/RBM - cross reference on
package · Double quick-connect terminals on coil · 2.13 x 1.88 x 2.25 in. · Base is designed for easy replacement of competitive relays · Molded terminal numbers and circuit diagram on top of relay · UL and CSA listings available
Full Load Amps Resistive Amps* Locked Rotor Amps
Horsepower *277 VAC
POWER 120V 208/240V
12 6
15 15
60 35
3/4 3/4
PILOT 120V 208/240V
- -
3 3
- -
1/10 1/10
1
3
2
4
6
5
MARS NO.
90340 90341 90342
90343 90344 90345
90346 90348
COIL VOLTAGE
24 110/120 208/240
24 110/120 208/240
24 208/240
TERMINALS 1-2-3 Power
Power
Pilot
Cross Reference Information
WR/RBM NO.
MARS REPLACEMENT
90-340
90340
90-341
90341
90-342
90342
90-343
90343
90-344
90344
90-345
90345
90-346
90346
90-348
90348
HONEYWELL NO.
R4222B1082 R4222B1090 R4222D1013 R4222D1021 R4222N1010 R4222V1002 R4222V1010 R8222B1067 R4222D1014 R8222N1011 R8222V1003
TERMINALS 4-5-6
Power
Pilot
Pilot
MARS REPLACEMENT
90344 90345 90341 90342 90348 90344 90345 90343 90340 90346 90343
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
C31
COMPONENTS
MARS General Purpose Switching Relays
SPST and SPDT Fan Relays
The MARS Series 903 relays are among the most popular relays used in air conditioning today. They will replace the WR/Essex/RBM Type 84 (90-290 thru 90-295) quick-connect and screw terminal versions. Features: · 0.25 inch quick-connect
terminals · Packaged with instructions and
cross reference · Replace 90-290 thru 90-295
and 90-290Q thru 90-295Q · Dimensions: 2.38 x 1.63 x 1.50 in. · Tab bracket, Non-positional · UL and CSA listings available
COIL VOLTAGE
24 110/120 208/240
MARS NO. SPST
90290 90291 90292
MARS NO. SPDT
90293 90294 90295
Contact Rating-- All Models/Amps
VOLTAGE
FULL LOAD
LOCKED ROTOR
RESISTIVE
120
12
60
18
240
8
48
18
277
7
42
18
Coil Data: 24-240 VAC @ 50/60 Hz; 5 VA Max. Inrush; 3.0 VA Max. Sealed
Cross Reference Information
WR/RBM MARS WR/RBM
NO.
NO.
NO.
MARS NO.
90-290 90290 90-293 90293
90-290Q 90290 90-293Q 90293
90-291 90291 90-294 90294
90-291Q 90291 90-294Q 90294
90-292 90292 90-295 90295
90-292Q 90292 90-295Q 90295
Heavy Duty Fan Relays
MARS Heavy Duty Fan Relays are used on heating and air conditioning equipment to provide switching of heavier loads with a compact size relay. MARS Heavy Duty Fan Relays replace WR/Essex/RBM type 184.
Features: · 0.25 inch quick-connect
terminals · Packaged with instructions
and cross reference · Replaces WR/Essex/RBM
Type 184 · Tab bracket,
Non-positional · UL and CSA listings
available
Contact Rating-- All Models/Amps
Coil Data
VOLTAGE
FULL LOAD
LOCKED ROTOR
RESISTIVE
COIL VOLTAGE
120
12
60
18
240
8
48
18
277
7
42
18
24 120 208/240
MAX INRUSH
5 VA 5 VA 5 VA
MAX SEALED
3 VA 3 VA 3 VA
COIL MARS NO. MARS NO. MARS NO.
VOLTAGE SPST
SPDT SPNO-SPNC
24
90360
90370
90380
110/120 90362
90372
90382
208/240 90364
90374
90384
277
90377
Cross Reference
WR/RBM MARS WR/RBM MARS NO. NO. NO. NO.
90-360 90-360 90-374 90374 90-362 90-362 90-380 90380 90-364 90-364 90-382 90382 90-370 90-370 90-384 90384 90-372 90-372
C32
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com
COMPONENTS
MARS Enclosed Switching Relays
MARS enclosed switching relays are heavy duty general purpose relays suitable for a variety of applications. They are commonly used in heating, air conditioning, vending machines, office machines, control panels and other general purpose applications. They are available in single pole, two pole and three pole models for either bracket or plug-in mounting. All MARS enclosed switching relays are protected by a tough polycarbonate cover to keep out dust and dirt. Blade type terminals fit standard plug-in mounts plus allow use with 3/16 inch quick-connect terminals or direct soldering.
43053
Features: · Simple connections · One, two and three pole
models · Plug-in or bracket mount · See-through protective cover · Three-way blade terminals,
plug-in, quick-connect or solder · UL and CSA listings available
Specifications: Dimensions: 2.0 X 1 1/2 X 1 3/8 Terminals: 3/16 blade Coil Data: 2.0 VA Contact Material: Silver alloy, gold flashed
43050
43058 93058
MARS COIL NO. VOLTAGE
43050
24
43053
24
43054 120
43056
24
43057 120
43058 240
43063
24
43064 120
43066
24
43067 120
43068 240
93058
HZ
AMP HORSEPOWER RATING 120V 240V
50/60 13
1/3
1/2
SWITCH ACTION
SPDT
50/60 13
1/3
1/2
DPDT
50/60 13
1/3
1/2
3PDT
50/60 13
1/3
1/2
DPDT
50/60 13
1/3
1/2
3PDT
Socket Base. Can be surface or DIN rail mounted.
TYPE MOUNT bracket bracket
bracket
plug-in plug-in
MARS Enclosed & Current Relays
MARS Current Relays - Universal Replacement
MARS current relays manufactured by General Electric can replace almost any current relay found on refrigerators, freezers, water cooler, pumps and vending machines.
Features: · Replace plug-on, bracket-
type, split-phase, and capacitor-start current relays · Covers replacement needs of 1/12 H.P. 115V to 1/8 H.P. 115V · Clearly labeled terminals for fast wiring · Each relay packaged with installation instructions and wiring diagrams · UL and CSA listings available
MARS GE NO. MAX
MIN APPLICATION SURVEY BY HORSEPOWER1
NO. 3ARR12 PAC PICK-UP DROP OUT
(AT 115)2
1/12 1/8 1/6 1/5 1/4 1/3 1/2 3/4
27001 309A
3.8
3.2
n n n n nnnn
27002 310A
5.2
4.4
n n n n nnnn
1. Current relays cannot be replaced by horsepower, amperage, or nameplate data alone. Refer to cross reference information for proper replacement of original equipment current relays by part numbers.
2. These current relays are often used on 230 volt applications, however this horsepower survey refers only to 115 volt applications.
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
C33
COMPONENTS
MARS Relays & Potential Relays
For Submersible Pump Applications
The MARS 550 and 551 relays were specifically developed for submersible pump and other motor starting applications in high moisture environments. Because the control panels for these are often located in areas of high humidity, the components on them must resist the effects of moisture. Chrome plating on the core and armature and the relatively small area of contact eliminates armature sticking due to organic contaminants which was the number one cause of relay failure.
Features: · Used on F.E. Meyers, Franklin
Electric, Jacuzzi, Red Jacket, Sta-Rite, and Tait · 2 relays replace over 25 O.E.M. relays · Universal break-off bracket on each relay. Simply snap off parts not needed · UL and CSA listings available
19550
One-On-OneTM Direct Replacement Potential Relays
The relays are exact replacements for Bristol & Copeland applications. They conform to specifications and in most cases are the one-on-oneTM replacement relay used by the manufacturer
Other relays available on special order. Contact your local wholesaler or MARS Customer Service.
16028
BRISTOL 650058 650855
BRISTOL 650971
COPELAND 040-0001-00 040-0001-01 040-0001-04 040-0001-12 040-0001-17 040-0001-19 040-0001-20 040-0001-25 040-0001-26
MARS 16028 16051
MARS 16083
MARS 16086 16093 16085 16098 16095 16089 16023 16035 16022
COPELAND 040-0001-34 040-0001-35 040-0001-48 040-0001-50 040-0001-53 040-0001-54 040-0001-55 040-0001-59 040-0001-60 040-0001-61 040-0001-62
MARS 16099 16090 16093 16085 16095 16089 16023 16090 16091 16086 16035
COPELAND 040-0001-64 040-0001-68 040-0001-71 040-0001-74 040-0001-78 040-0001-79
COPELAND 040-0001-88 040-0001-89
MARS 16098 16099 16116 16122 16121 16152
MARS 16151 16155
MARS MARS CONTINUOUS NO. MODEL NO. COIL VOLTAGE
19550 MARS 550
130
19551 MARS 551
332
PICK-UP
MIN.
MAX
111
134
244
270
DROP-OUT
MIN.
MAX
15
40
40
90
MARS NO.
16104
G.E. NO. 3ARR3J3G3
USED BY Barnes [Burks, Decator] & Myers
MANUF.
OEM NO.
13178-A
GE MARS CAT. NO. NO.
3ARR3D7J4 19550
13179-A 3ARR3D3V4 19551
13180-A 3ARR3D3A4 19551 F.E. Myers
17891-A 3ARR3EA3A4 19551
17890-A 3ARR3EA3V4 19551
17889-A 3ARR3EA7J4 19550
155031-101 3ARR3J7J4 19550
Franklin Electric
155031-102 3ARR3J9V4 155031-104 3ARR3J2P3 155031-103 3ARR3J9U4
19551 19550 19551
155031-105 3ARR3J7M1 19550
MANUF
OEM NO.
GE CAT. NO.
23-1308-26 3ARR3EA9V5
23-1308-00 3ARR3EA7J5
23-1308-18 3ARR3EA7BB5 Jacuzzi
23-1308-34 3ARR3EA5U5
23-1308-42 3ARR3EA7M5
23-1308-49 3ARR3EA5C5
71-69 3ARR3EA7M5
Red Jacket
71-70
3ARR3EA5B5
71-47 3ARR3J3V2
U18-325 3ARR3J3V3
U18-665 Sta-Rite
U18-810
3ARR3J3A3 3ARR3J2P3
U18-811 3ARR3J5V3
A124P2 3ARR3EA5A5 Tait
A124P1 3ARR3EA7K5
MARS NO. 19551 19550 19550 19551 19550 19551 19550 19551 19551 19551 19551 19550 19551 19551 19550
Universal Replacement
Quick Reference Relay Selection Chart For General Electric Relays
1. Determine the General Electric model number of the Relay to be
replaced the "FORM" and "GROUP"
One number plus
1 or 2 Letters 1 or 2 Letters
EXAMPLE:
3ARR3*
A
3B
3
Basic Type
FORM
GROUP Non-Positional
Cross Reference Information
WR/RBM NO. 90-1 90-2 90-3 90-4 90-5 90-6 90-7 90-8 90-9 90-10 90-11 90-12
90-13 90-14 90-15 90-16 90-17 90-18 90-19 90-20 90-21 90-22 90-23 90-24
MARS NO. 19002 19009 19004 19003 19006 19006 19004 19003 19007 19008 19003 19007
19005 19003 19006 19007 19002 19008 19006 19007 19002 19003 19007 19008
WR/RBM NO. 90-25 90-26 90-27 90-40 90-41 90-63 90-64 90-65 90-66 90-67 90-68 90-69
MARS NO. 19006 19008 19005 19004 19008 19002 19003 19004 19005 19006 19007 19001
TECUM. NO. 82777 82778 82779 82781 82783 82784 82785 82787
MARS NO. 19002 19004 19008 19010 19003 19009 19006 19007
2.Locate in the following table the Relay GROUP and select the corresponding MARS Replacement Relay from the kit.
19002 MARS 63 replaces Relay GROUPS 2J; 2K; 2L; 2M; 5N; 7J; 7K; 7L: 7M; 7N; 8L; 8M; 8N
19003 MARS 64 replaces Relay GROUPS 3A; 3B; 3AV; 3AU; 4A; 4B; 6A; 6B; 6AV; 10A; 10B; 10AU; 10AV
19004 MARS 65 replaces Relay GROUPS 3P; 3R; 3AP; 5P; 5R; 5S; 5T; 22S
19005 MARS 66 replaces Relay GROUPS 3U; 3V; 3AT; 6U; 6V; 6W
19006 MARS 67 replaces Relay GROUPS 3C; 3D; 3AA; 4C; 4D; 4BK; 6C; 6D; 6AA; 10C; 10D; 26A; 26B; 26C; 26D
19007 MARS 68 replaces Relay GROUPS 3E; 3F; 3AB; 3AC; 4E; 4F; 4G; 6E; 6F; 6G; 10H; 10AB; 10AC; 26E; 26F; 26G; 26H; 27E; 27F; 27G
19008 MARS 69 replaces Relay GROUPS 3S; 3T; 10S; 10T; 25S; 25T; 10AS
19009 MARS 70 replaces Relay GROUPS 5B; 5C; 5D; 5AA; 8B; 8C; 8D
19010 MARS 71 replaces Relay GROUPS 6TV; 6TW; 10V
3. Install relay in accordance with instructions in MARS Replacement Kit
C34
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com
COMPONENTS
MARS Potential Relays
MARS Universal Replacement
The MARS refrigeration potential relay service kit has become an industry standard since its introduction over fifty years ago. Its long-term reliability and easy replacement have been the key to its success. The wide calibration ranges and the universal bracket make the MARS potential relay service kit a must on every service truck.
19002 19001
Features:
· Genuine MARS relays replace thousands of O.E.M. models
· Non-positional
· Wide range of selectivity
· QC-6 Kit included with each relay to convert screw-on to push-on
· Instructions and wiring diagram included in each relay
· Universal break-off bracket on each relay. Simply snap-off parts not needed
93001
· The six most popular relays available in a service kit--19001 MARS 6 PAK--complete cross reference guide included in each kit
· UL and CSA listings available
MARS HVAC Potential Relays
MARS series relays are manufactured for the HVAC industry. These relays meet all requirements for original equipment relays.
Features: · 50/60 Hz · cULus · Contact rating 35 amp, 400
VAC · Operating position tab up · Instructions and wiring
diagram included in each relay · Class "B" insulation
19163 WIRING DIAGRAM
.12
.02
1.59 1.85
1.38
2.00
1.69
.08
Calibration Specifications
MARS NO.
MARS MODEL NO.
CONTINUOUS COIL VOLTAGE
19001 MARS 6 PAK
--
19002
MARS 63
170
19003
MARS 64
395
19004
MARS 65
332
19005
MARS 66
395
19006
MARS 67
420
19007
MARS 68
502
19008*
MARS 69
336
19009*
MARS 70
253
19010*
MARS 71
420
93001
QC-6
--
*Not included in 19001 MARS 6-Pak
PICK-UP
MIN.
MAX
--
--
139
153
260
275
168
182
215
225
295
315
325
345
180
195
285
305
212
232
--
--
DROP-OUT MAX
-- 55 120 90 120 125 135 105 77 121 --
Calibration Specifications
MARS NO.
MARS MODEL NO
CONTINUOUS COIL VOLTAGE
19163
MARS 163
168
19164
MARS 164
420
19165
MARS 165
332
19166
MARS 166
420
19167
MARS 167
420
19168
MARS 168
502
19169
MARS 169
332
19170
MARS 170
253
19171
MARS 171
420
Note: If used on 50 Hz, the PU will be about 13% lower
PICK-UP VOLTAGE
140-153 242-272 171-184 204-233 300-328 314-342 180-193 285-305 204-233
DROP-OUT VOLTAGE
20-45 60-121 40-90 60-121 60-121 60-135 40-90 35-77 60-121
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
C35
COMPONENTS
Leak Detectors
MARS H-10 Pro Universal Refrigerant Leak Detector
The MARS H-10 Pro combines and enhances all the features of the previous H-10 Series models into one full featured unit. The H10 Pro Refrigerant Leak Detector continues to be the universal standard for checking halogenbased refrigerant leaks in residential and commercial applications. With automatic auto zero balance control it's unique sensor calibration system will pinpoint small, medium and large leaks. The instrument uses a tried-and-true positive ion emission heated diode with audible and visual leak rate indicators. It is the most sensitive and accurate leak detector to detect all CFC, HFC and HCFC refrigerants as low as 0.006 oz/yr, including R-410a and R-507. The unit is mounted in a durable carry case which houses the 4.5 foot probe with built in filter, carrying strap, wall adapter and operating instructions.
Features:
· All CFC, HFC and HCFC refrigerants, including but not limited to: R-12, R-22, R-134a, R-404A, R-410A, R-502, R-507, HFO-1233zd, HFO-1234yf and HFO-1234ze
· Improved sensor responsiveness with ultra-sensitive detection
· Dual power sources include rechargeable battery or external DC powered (wall adapter included)
· Selectable sensitivity to pinpoint small, medium or large leaks
· Unique visual sensor calibration system (with included reference leak bottle)
· Rugged enclosure with shoulder strap included
· Manual or automatic zero modes
· Headphone port allows for optional headset use in high-noise environments
Specifications: Nominal Leak Range: 0.006 oz/yr (stationary) | 0.1 oz/yr (moving probe per SAE J2791) Power Supply: 12 VDC - internal rechargeable sealed lead acid battery; 100-240 VAC wall adapter/universal battery charger to charge or run continuously Reference Leak: Approx. 0.006 oz/yr (stationary) | 0.1 oz/yr (moving probe per SAE J2791), 1 year life (typical) Ambient Operating Temp: 32°F to 104°F (0°C to 40°C) Battery Life: 3 hours (typically) Warm Up Time: Approx. 2 min. Response Time: 1 second Gases Detected: All CFC, HFC and HCFC non-flammable refrigerants Detection Principle: Positive Ion Emission Heated Diode Probe Length: 4.5 feet Dimensions: 10.5" L x 8.3" W x 5.4" H NOTE: sensors are consumed in normal operation. It is good practice to have a spare sensor available at all times.
MARS NO.
25301
CATALOG NO.
H-10 Pro
DESCRIPTION
Universal Refrigerant Leak Detector, Wall adapter or Battery Powered
Renewal Parts
MARS stocks genuine renewal parts for MARS, GE, and Bacharach H-10 Series Leak Detectors.
25315
25321
Renewal Parts For H-10 Professional, H-10N, H-10G, and H-10B
MARS CATALOG
NO.
NO.
25310 M1101UD
25315 H10N04 25314 M1101UU 25309 E7076DX 25325 M1101AH 25333 M1101VS
DESCRIPTION Maintenance kit (100 filters,
3 rubber probe tips) Plug-in sensor element Probe tip - clear plastic
Rubber tip for probe Battery charger - 120-240 VAC
Cigarette lighter adapter
H-10 PRO/PM
H-10N
H-10G
H-10B
3333
3333
3333
333 3 33
25323 M1101UC
Super tune up kit; sensor, leak vial, 100 filters
3 flow balls and 3 rubber probe tips
3333
25326 M1101AD 25321 K9344AH
Battery for H-10 Pro Reference Leak Assembly
3 3333
C36
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com
COMPONENTS
MARS Solid State Motor Starting Devices & Solid State Timers
MARS Solid State Motor Starting Relay for Refrigerators and Freezers
MARS 32330 is a solid state PTC motor starting relay that mounts directly to any 3-pin fusite connector. One model replaces thousands of current relays used on 1/12 HP to 1/3 HP compressors.
Features: · Replaces Tecumseh Relays SSR2 and
SSR3 for push-on applications. · Non-positional · One model for 1/12 HP to 1/3 HP, 120 volt · UL and CSA listings available
MARS NO.
32330
HORSEPOWER 1/12 - 1/3
VOLTAGE 120
32330
MARS Solid State Timers Delay On Make
The MARS 32391 is the top-selling timer in the industry. Its reliability has been proven in the field by knowledgeable contractors.
The MARS 32391 will not be fooled by the thermostat anticipator.
Heavy duty MARS timers are offered for higher current applications.
32391
Features: · Easy two-wire installation · Proven reliability, all solid state · .25 in. quick connect terminals · Mounts in any position · Compact size · High accuracy · Totally enclosed and
encapsulated for proper heat dissipation
32394
Specifications:
· .040 amps min. latch current
MARS TYPE NO. DELAY
TIME DELAY RANGE
TYPE OF
ADJUSTMENT
INPUT VOLTAGE
HZ
MAX AMPS.
VOLTAGE DROP
CONN. DIA.
32391 on make 6 sec...8 min.
dial
19...240VAC 50/60 1
2.5 at 1 amp.
1
slide switch
32394
on make 1 sec..1023 sec.
adjustable in 1 second
19...144VAC
50/60
1
2.5 at 1 amp.
1
increments
Mars Solid State Timers Delay On Break
MARS solid state delay on break timers are designed to prevent short cycling of air conditioning, refrigeration and heat pump compressors. Upon application of power the load is energized. When the thermostat opens, or if there is a momentary loss of power, the load is de-energized and the delay period begins. The compressor will not start again during the delay period.
32392 32390
MARS number 32392 is a versatile
two wire timer that features
adjustable timing and can be used
with any voltage from 19 thru 240
VAC, 50 or 60 Hz. The MARS 32390 and the new
32505
32505 are the most simple and
economic ways to stop short
cycling on 24 VAC controlled
systems. Both devices are fixed 5 minute delay on break timers.
Features: · 1 to 3 second random re-start · Dial adjustable · Compact size · Mounts in any position · .25 in. quick connect terminals · Proven reliability · MARS delay-on-break timers are not load
sensitive
Adjustable
MARS TYPE NO. DELAY
32392 on break
TIME DELAY RANGE
6 sec...5 min.
TYPE OF
ADJUSTMENT
INPUT VOLTAGE
HZ
MAX AMPS.
VOLTAGE DROP
dial
19...240VAC 50/60 1
2.5 at 1 amp.
Fixed Delay
32390 on break 32505 on break
5 min. 5 min.
none
24 VAC 50/60 1
2.5 at 1 amp.
none
20-30 VAC 50/60 1
3 at 1 amp.
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
C37
COMPONENTS
MARS Solid State Timers & Devices
Fan Time Delay Module
The MAHBC fan time delay module is a replacement for the direct motor control used by leading OEMs in high efficiency residential central air conditioning systems. The purpose of the control is to keep the blower motor running for 60 seconds after the thermostat has been satisfied. The result is an increase in residual cooling from the indoor coil without running the condensing unit, and thus, higher energy efficiency.
The MAHBC is ideal for retrofit where improved efficiency is desirable.
32574
Features:
· Wide ambient temperature operating range -40°F to 175°F
· 1/4" male quick connect terminals
· Easy surface mount with four #6 screws
· UL and CSA recognized
Cross Reference
OEM
PART NO.
BARD
8201-056
RHEEM
42-22515-01
SNYDER GENERAL
0001395336
MARS NO.
32574
MARS MODEL
MAHBC
VOLTAGE 24VAC
OUTPUT
120V
240V
1 HP
2 HP
TIME DELAY
60 SEC.
ACTION SPDT
MARS Bypass Timer
MARS 32395 is an adjustable, multi-voltage bypass timer that allows the temporary bypass of a control or device during startup. At the end of the delay period the control is returned to the circuit. Eliminate nuisance trips!
32395
Compressor Anti-Short Cycle Timer with Low Voltage Brownout Protection
Delay on break.
OEM replacement timers for Lennox, Rheem, Ruud, Trane, Heil Quaker, Keep Rite, Mc Quay, Snyder General and others.
Features:
· Lockout delay prevents rapid cycling compensated resistor type wall thermostats
· Single hole mounting (.25 inch diameter)
· Non-positional
· Brownout protection prevents startup when voltage is below normal conditions
· Reduces nuisance service calls due to short cycling
· Delay on Break Lockout delay starts with opening of thermostat or loss of power
· .25 in. quick-connect terminals
· Eliminates relay chatter due to thermostat bounce
· Small size 2.00 x 2.00 x .75 in.
· UL and CSA listings available
32381
Operation: On initial closure of the thermostat, the compressor relay energizes immediately. When the thermostat opens, a lockout condition and a time delay is initiated. During this lockout time delay period, the compressor cannot be energized. Brownout protection prevents energizing of the compressor when the line voltage is below normal conditions.
With Integral Brownout Protection
MARS NO.
MODEL NO.
OPERATING VOLTAGE (NOMINAL)
32381
TA24A3
24 VAC
32382
TA24A5
24 VAC
TIME DELAY (MIN.) ± 2%
3
5
MARS NO.
1.5 1.5
Low pressure switch bypass application.
FIGURE 1 LOAD IS BYPASSED ON RETURNS TO CIRCUIT AFTER DELAY PERIOD.
MARS TYPE TIME DELAY TYPE OF INPUT NO. DELAY RANGE ADJ. VOLTAGE
HZ
MAX VOLTAGE CONN. AMPS DROP DIAGRAM
32395 by-pass 6 sec...8 min. dial 19...240VAC 50/60 1 2 at 1 amp. 1
C38
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com
COMPONENTS
MARS Solid State Timers & MARS 3/4" Motor Protectors
MARS Fan Delay/Post Purge Timers
These MARS solid state timers provide for convenient control of a variety of functions. MARS number 32393 is a fixed 2 minute, 24V off-delay timer that allows the fan to continue to operate after the thermostat is satisfied to purge the ducts of conditioned air.
Features: · Wide selection of models · Easy installation · Compact size · Mounts in any position · Totally solid state · High accuracy
Specifications: · 100 milliamps minimum
latch current
32393
MARS Universal Replacements for Refrigeration and Air Conditioning
30 MARS motor protectors solve the serviceman's most annoying problem--finding suitable replacements for motor overload protectors.
Features:
· Used in refrigeration, room air conditioners, heating, appliances, and electric motors
· Each overload has six-inch leads and two wire nuts for simple installation
· UL and CSA listings available
35009
Application Survey By Horsepower*
MARS NO.
110/115
HORSEPOWER
208/240V
1/20 1/12 1/8 1/6 1/5 1/4 1/3 1/2 1/12 1/8 1/6 1/5 1/4 1/3 1/2 1
35010 n n n n n n n n n n n n n n n n
With the switch closed, the load is energized. when the switch opens, the load remains energized and the time delay begins. at the end of the delay
period the load is de-energized.
When the switch closes, the time delay begins. at the end of the delay period, the load is de-
energized.
MARS TYPE TIME DELAY TYPE OF INPUT NO. DELAY RANGE ADJ. VOLTAGE
HZ
MAX VOLTAGE CONN. AMPS DROP DIAGRAM
32393 off delay 2 min. fixed --
24 VAC 50/60 1
2 at 1 amp.
1
35011 n n n n n n n n n n n n n n n n 35012 n n n n n n n n n n n n n n n n 35014 n n n n n n n n n n n n n n n n 35015 n n n n n n n n n n n n n n n n 35016 n n n n n n n n n n n n n n n n 35017 n n n n n n n n n n n n n n n n 35018 n n n n n n n n n n n n n n n n 35019 n n n n n n n n n n n n n n n n
3/4" A/C Overloads
MARS NO.
TEMPERATURE CODE
35101 35105
MRA-3763-529 MRP-00-AIU-529
*Motor protectors cannot be replaced by horsepower, amperage, or nameplate data alone. Refer to cross reference information for proper replacement of original equipment motor protectors by part number.
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
C39
COMPONENTS
Klixon 3-Phase Motor Protectors & Commercial Refrigeration Thermostats
On-Winding Overheat Protection
Refrigeration Cases and Coils
Klixon SL-11 kits are mounted on the windings of general purpose motors and hermetically sealed
®
compressors. They supplement conventional current overload relays in magnetic starters providing modern total protection for most older motors in use today.
Features:
· Allow motors to perform at full-load capacity but will protect against dangerous running overloads
37090
· Protect against blocked ventilation, high ambient temperatures, single phasing
· Each kit contains three matched motor-winding thermostats
· When starter overloads operate, the SL-11 will protect against re-starting at unsafe winding temperatures.
· These motor winding thermostats do not replace overloads in the starter
· UL & CSA listed
Installation:
SL-11 thermostats are tied in place on the end turns of appropriate winding bundles, one to each phase or buried in the windings during motor rewind. They are connected in series between the starter coil and its power supply.
Selection:
· Pick thermostat temperature to operate at the mid-point between the "maximum normal running" temperature and the "maximum allowed running temperature."
· Subtract the gradient temperature (outlined in the chart below) from the mid-point to obtain the operating temperature of the thermostat.
Epoxy-Sealed Thermostats For General Purpose Motors Normally Closed
MARS NO.
KLIXON KIT NO
KLIXON CAT. NO
OPERATING TEMPERATURE
37075
SL-11-75
37090
SL-11-90
37100
SL-11-100
37110
SL-11-110
37120
SL-11-120
37130
SL-11-130
37135
SL-11-135
37140
SL-11-140
37145
SL-11-145
37150
SL-11-150
Three thermostats per package
9700K51-146 9700K21-146 9700K26-146 9700K36-146 9700K01-146 9700K11-146 9700K06-146 9700K66-146 9700K76-146 9700K46-146
75°C 90°C 100°C 110°C 120°C 130°C 135°C 140°C 145°C 150°C
Typical Gradiants
Motor Type
Open Type Totally Enclosed
Fan Cooled Totally Enclosed Non-Ventilated
Thermostat Location
Tied On End Turns
Buried In End Turns
30°C
15°C
25°C
10°C
20°C
5°C
Maximum Contact Rating Amps Klixon # 24V 115V 230V 9700K 18 18 12
MARS has selected the most popular Klixon disc-type thermostats found in commercial refrigeration. These controls cover a wide assortment of applications including supermarket cases and walk-in, reach-in, and beverage coolers.
Features:
· Used on refrigeration cases, coils, with many other commercial applications
· Long lead wires supplied to satisfy most requirements
· Used by Hussman, Friedrich, Larkin, Schaefer, etc.
· 1 inch discs fully encapsulated for trouble-free use
· Mounts directly on coil tube or surface for maximum temperature response
· UL and CSA listings available
· 25 resistive amps maximum
ELECTRICAL RATING
TERM. TERM.
1-3
1-2
Full load 120V
13
5.8
amps
240V
10
2.9
Locked 120V
60
34.8
rotor amps 240V
45
17.4
Pilot Duty 120/240V 125
125
Resistive 120/240V 25
25
amps
277V
15
15
33405
®
33017
Tube Mounting
MARS NO.
KLIXON NO.
O.E.M.
O.E.M. SWITCH PART NO. ACTION
33405 20420D24-106-63 Bally
--
D
33415 20420D24-399-350
--
D
33420 20428F1-4-676 Friedrich 606-038-00 F
33425 20420L15-913-302
794-824-00 L
33430 20420D1-166-336
--
D
33435 20420L28-229-89 Hussman P211-119696 L
33440 20420F32-381-533
--
F
33455 20420F19-63-294 Schaefer C10872-19 F
33460 20420L19-202-274
C10872-6 L
33470 20420L15-376-218
125211
L
33475 20420L15-722-218 Tyler Ref. 146291
L
33480 20420L15-767-257
146739
L
OPERATING TEMPERATURES F°
OPEN CLOSE
70
20
65
20
35
55
40
25
50
35
20
5
20
30
20
60
35
5
50
30
40
20
80
50
TUBE MT. IN
LEADS IN
5/8 18
5/8 20
3/8 20
5/8 11
1/2 18
3/4 40
3/4 48
5/8 36
5/8 54
5/8 36
5/8 36
5/8 90
Surface Mounting
MARS NO.
KLIXON NO.
O.E.M.
O.E.M. PART NO.
SWITCH ACTION
OPERATING TEMPERATURES F°
OPEN CLOSE
33017 20425L153-B22-B54 Heatcraft 5708L L
75
40
LEADS IN
18 w/ quick connects
1D=SPDT, no. 1 is common (white) - no label, no. 2 either opens or closes temp. rise - red label, no. 3 is opposite of no. 2 - blue label F= close on temperature rise, SPST L= open on temperature rise, SPST 2
C40
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com
COMPONENTS
Commercial Refrigeration Thermostats & Defrost Thermostats
Change-Over Switches for Fan-Coil Systems
For Defrost Termination
The MARS Series 390 change-
over switches are used for
summer-winter change-over of
®
electric thermo-stats in hydronic
heating - cooling fan-coil units.
Features:
· Color coded leads allow easy installation
· SL-8 thermostat is enclosed in sealed case for trouble-free operation
· Snap-acting disc type, insures accurate temperature repeatability
· Can be mounted in any position
· UL and CSA listings available
39004 Leads thru side
Installation:
The SL-8 change-over switch is located on the main run of the supply line where it can quickly
39005 Leads thru top 1/2" conduit adapter
sense the maximum
temperature of the hot or cold
water passing through. If the SL-8 switch is exposed to
LINE VOLTAGE OPERATION GND LINE HOT
surrounding temperatures, thermal insulation should be wrapped around the switch
FAN COIL UNIT
HEATING SIDE
ROOM THERMOSTAT COOLING SIDE
case to maintain desired thermal response.
Specifications: Pipe size: 5/8 in O.D. Leads: 12 in. color coded
RETURN LINE
MOTORIZED VALVE SUPPLY LINE
HOT OR COLD WATER
SL-8 CHANGE-OVER SWITCH
WHITE COMMON
BLUE
NORMALLY OPEN
RED
NORMALLY CLOSED
Switch Action: SPDT
Temperature: 88°F (31°C)-- terminals 1 & 2 close, 1 & 3 open 73°F (23°C)--terminals 1 & 3 close, 1 & 2 open
Mounting: mounting clip supplied with each kit
Electrical: terminals 1 & 3 25 amp at 120/240 VAC
Terminals 1 & 2 10 amp at 120 VAC, 5 amp at 240 VAC
Honeywell MARS
White
MARS
No.
No. Rodgers No, No.
L6076A 39004
752-1
39004
L6076B 39005
752-2
39005
MARS Series 330 defrost controls are designed to replace many defrost thermostats. The leads are of sufficient length for the connection to be made at the same location as was the control removed. The connection should be insulated in a manner similar to that on the original equipment.
The selection of the proper thermostat can be made by matching the temperature code of the thermostat removed to the code on the MARS Thermostat.
33008
Features:
· Refrigerators, A/C units, & heat pumps, dehumidifiers, icemakers or any place where a fixed temperature control is required in a wet or dirty environment.
· Thermostats have 32" leads.
Temp. Code
Use MARS
No.
Temp. Code
Use MARS
No.
Temp. Code
Use MARS
No.
L40-3.0
L58-4.3
L65-4.0
L42-2.0 L45-3.0
33008
L60-2.0 L60-2.5
L67-4.2 L70-4.0
33012
L45-3.0
L60-3.0 33011 L75-5.0
L60-3.5
L55-1.5
L60-4.0
L80-3.0
L55-2.0
L60-4.5
L55-2.5 L55-3.0
33010
L80-4.0 L80-4.5
33020
L80-5.0
L55-3.5
L55-4.0
MARS NO.
33008 33010 33011 33012 33020
TEMP. CODE
L45 L55 L60 L70 L80
OPENING CLOSING TEMP. F° TEMP F°
45
25
55
35
60
40
70
50
80
60
VOLTS
120 240
INDUCTIVE
F.L.A.
L.R.A.
5.8
25
2.9
70
MARS Freeze Stat
The MARS 33101 is designed to help stop flood back to compressor crankcases caused by low ambient temperatures.
Features: · Simple to install · Refrigerators, freezers, A/C,
food dispensing equipment · For use with 1" pipe,
1/2' radius · 24" leads
33101
MARS NO. 39004
39005
KLIXON KIT NO. SL8-5
SL8-5A
KLIXON NO.
20425D27-160-356
DESCRIPTION leads thru side of cup
20425D69-160-287
leads thru top of cup with 1/2" conduit adapter
MARS NO.
33101
OPENING TEMP. F°
34
CLOSING TEMP F°
45
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
C41
COMPONENTS
Klixon Pressure Switches & MARS Pressure Switches
Fixed Setting Pressure Controls
Low pressure controls.
Specifications:
· Contacts rated at 6 amps,
®
24-240 volts
· 18" leads
Features:
· Tamper proof construction
· Direct mounting on tubing
· UL & CSA recognized
The 4 - Series Klixon Pressure
43341
Switches. This newest set of
designs delivers the reliability and
performance that has made Klixon the most trusted name in the
electromechanical sensor business. The 4 - Series line of pressure
switches covers many new R410A applications along with traditional
pressure setting switches.
Klixon Brand, UL and CUL, Compact size, light weight for direct mounting, Factory Set, Hermetically Sealed Sensor.
5.8 FLA - 34.8 LRA @ 120 VAC, 2.9 FLA - 15.0 LRA @ 240 VAC, 100,000 Cycle Life at Rated Current.
Low Pressure Cut-Out - Open on Pressure Drop, Automatic Reset Normally Open
4 SERIES OPENING RESET PRESMARS NO. PRESSURE SURE
NOTES
43341
5
20
1/4" Female Flare S.A.E. Mounting
43342
5
30
1/4" Female Flare S.A.E. Mounting
43343
10
25
1/4" Female Flare S.A.E. Mounting
43344
15
35
1/4" Female Flare S.A.E. Mounting
43345
20
45
1/4" Female Flare S.A.E. Mounting
43372
22
50
1/4" Copper Clad SS Tube w/38" leads
43373
25
40
Gold Contacts 1/4" Female Flare w/36" leads
43346
25
50
1/4" Female Flare S.A.E. Mounting
43347
25
65
1/4" Female Flare S.A.E. Mounting
43348
25
80
1/4" Female Flare S.A.E. Mounting
43349
35
60
1/4" Female Flare S.A.E. Mounting
43350
40
80
1/4" Female Flare S.A.E. Mounting
43351
45
60
1/4" Female Flare S.A.E. Mounting
43352
50
90
1/4" Female Flare S.A.E. Mounting
43374
50
95
1/4" Copper Clad SS Tube w/36" leads
43353
75
100
1/4" Female Flare S.A.E. Mounting
43375
90
120
1/4" Female Flare, w/18" leads
43354
150
225
1/4" Female Flare S.A.E. Mounting
43355
170
250
1/4" Female Flare S.A.E. Mounting
Fixed Setting Pressure Controls High Pressure Cut-Outs
MARS offers the most complete line of high pressure cut-outs available.
Specifications:
· Contacts rated at 6 amps, 24-240 volts
· 1/4" female flare S.A.E. mounting
· 18" leads
Features: · Tamper proof construction · Direct mounting on tubing · UL & CSA recognized
43337
MARS Pressure Switches deliver the reliability and performance that makes them the most trusted electromechanical sensor. The MARS line of pressure switches cover many new R410A applications along with traditional pressure setting switches.
UL and CUL, Compact size, light weight for direct mounting, Factory Set, Hermetically Sealed Sensor.
5.8 FLA - 34.8 LRA @ 120 VAC, 2.9 FLA - 15.0 LRA @ 240 VAC, 100,000 Cycle Life at Rated Current.
High Pressure Cut-Out - Open on Pressure Rise, Automatic Reset, Normally Closed
MARS NO.
OPENING RESET PRESPRESSURE SURE
43337
200
150
43321
225
150
43322
250
150
43324
275
195
43325
300
200
43326
325
225
43320
350
245
43327
350
250
43328
375
275
43329
400
200
43330
400
280
43331
400
300
43311
410
290
43332
425
300
43333
425
325
43334
450
250
43365
590
418
43335
600
475
43366
610
420
43339
630
480
43367
650
450
NOTES
1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting
1/4" Female Flare S.A.E. Mounting w/24" leads
(1 stripped, 1 w/1/4" female flag QC) 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting
1/4" Female Flare w/snubber 1/4" Female Flare S.A.E. Mounting
1/4" Copper Clad SS Tube, 90 degree elbow w/snubber 1/4" Female Flare S.A.E. Mounting 1/4" Copper Clad SS Tube w/snubber
C42
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com
COMPONENTS
MARS Pressure Switches & Heat Pump Thermostats
Condenser Fan Cycling Switches
Fan cycling switches provide refrigeration and air conditioning from low ambient conditions.
Specifications:
· Contacts rated at 6 amps, 24-240 volts
· 1/4" female flare S.A.E. mounting
· 18" leads
Features: · Tamper proof construction · Direct mounting on tubing · UL & CSA recognized
43301
Fan Cycling - Close on Pressure Rise
MARS NO.
OPENING RESET PRESPRESSURE SURE
NOTES
43301
75
100
43302
110
170
43303
125
265
43304
150
225
43305
190
275
43370
180
240
43306
210
275
43307
300
400
1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare, S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting
Heat Pump Defrost Thermostats
MARS heat pump defrost thermostats are designed for direct replacement of most existing controls of this type. The temperature settings and tubing sizes have been carefully selected from the most popular OEM settings. Each MARS thermostat comes complete with extra long 54 inch leads, mounting clamp, and installation instructions for fast and simple field installation.
33490
Features:
· Four controls cover most requirements
· Tapered mounting edge for maximum heat transfer
· Extra long 54 inch leads for simple wiring
· Individually boxed with mounting clamp and instructions
· UL & CUL listed
Electrical Ratings:
Cycles X1000
Volts
FLA
100
120VAC
5.8
100
240VAC
2.9
30
120VAC
10.0
30
240VAC
10.0
100
30VDC
LRA
Resistive Amps
VA
34.8
10
125
17.4
10
125
40.0
40.0
1
Manual Reset - High Pressure Cut Out Open on Pressure Rise
MARS NO.
33490 33492 33494 33496
OPERATING TEMPERATURES F°
OPEN
CLOSE
80
30
80
30
65
30
65
30
TUBE MOUNTING IN LEADS IN
3/8
54
1/2
54
3/8
54
1/2
54
43312
MARS NO.
OPENING RESET PRESPRESSURE SURE
43312
375
Manual
43313
410
Manual
43314
415
Manual
43315
440
Manual
43316
475
Manual
43368
590
Manual
43369
610
Manual
NOTES
1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting
Capilllary Tube Capilllary Tube 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare w/snubber 1/4" Female Flare w/snubber
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
C43
COMPONENTS
Compressor Heaters
TUTCOTM Compressor Heaters for A/C and Refrigeration
Features: · Corrosion resistant exterior · High temperature silicone rubber element and insulated leads · 30" leads · Wattage for each model matches compressor requirements · Completely moisture proof · Installs quickly and easily · Nominal power consumption · UL & CSA Listed
Application Reference Chart for TUTCOTM Compressor Heaters
Manufacturer
Aspera Aspera Bendix/Westinghouse Bendix/Westinghouse Bendix/Westinghouse Bristol/Sundstrand Bristol/Sundstrand Bristol/Sundstrand Carrier Carrier Carlysle Copeland Copeland Copeland Copeland Copeland Copeland Fedders/Chrysler Fedders/Chrysler Hitachi Hitachi Hitachi Sanyo Tecumseh Tecumseh Tecumseh Tecumseh Tecumseh Tecumseh Trane Trane Trane Westinghouse Westinghouse
Model
H J A C, D E H10A, H21A, H2EA, H22A H10B, H20B, H21B, H22B H10G, H20G, H21G, H22GN2NG-144 6A25, 26, 28, 29, 6A35, 38, 45, 48 6A88 W (70-88) BR CR JR RR, SR VR Y 3009 2870908 1500FH4-H 305FH2-HE, 402FH2-HE, 505FH2-HE 753FH3-H, 1001FH4-H CR15F, CR20F, CR33F AB, AW AH AJ AK B, C, CL, AG, AV FE, FB D4340/7669 D4340/7670 D4350/689, D4359/690 CD072, CD090 CD072, CD090
MARS No.
32605-32608 32609-32611
32613 32601-32604 32605-32608 32605-32608
32613 32617-32620 32605-32608 32617-32620 32601-32604 32634-32635 32605-32608 32629-32630
32613 32621-32624 32601-32604 32617-32620
32631 32617-32620 32613-32616 32601-32604
32631 32613 32605-32608 32609-32611 32629-32630 32601-32604 32617-32620 32609-32611 32621-32624 32605-32608 32605-32608 32621-32624
32601
MARS NO.
DESCRIPTION
32601 32602 32604 32605 32608 32609 32610 32611 32613 32617 32619 32620 32621 32624 32629 32630 32631 32634 32635
CH-100 CH-100-1 CH-100-3 CH-101 CH-101-3 CH-102 CH-102-1 CH-102-2 CH-103 CH-104 CH-104-2 CH-104-3 CH-105 CH-105-3 CH-135 CH-135-2 CH-197 CH-202-2 CH-202-3
VOLTS
240 208 480 240 480 240 208 120 240 240 120 480 240 480 240 120 240 120 480
WATTS
50
54
60 45 75
50 45 25 70
INCHES
MIN. 30 3/16 30 3/16 30 3/16 27 7/16 27 7/16 25 3/4 25 3/4 25 3/4 24 3/4 41 1/2 41 1/2 41 1/2 32 1/2 32 1/2 20 5/16 20 5/16 13 3/4 33 3/4 33 3/4
MAX 37 37 37 34 1/4 34 1/4 32 9/16 32 9/16 32 9/16 31 9/16 48 5/16 48 5/16 48 5/16 39 5/16 39 5/16 27 1/8 27 1/8 20 9/16 36 3/4 36 3/4
SHAPE
OVL
OVL
OVL OVL RND
RND OVL RND RND
C44
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com
COMPONENTS
Crankcase Heaters
Direct Replacement Crankcase Heaters for Copeland
Figure 1
32408
Self Regulating Crankcase Heaters
MARS self-regulating crankcase heaters are designed for use with refrigeration compressors up to 5HP and 40 inches in circumference. These heating cables provide peak heat during cold periods and reduced heat when the air temperature rises and should be used in non-hazardous areas. · Cold length: 30" · Heat cable length: 50"
Crankcase Heaters for Copeland
NOTE: All heaters requiring clips or brackets are packaged with the appropriate clips or brackets required.
MARS NO.
COPELAND NO.
WATTS
VOLTS
HEATER LENGTH
IN.
FIGURE
COMPRESSOR MODEL
ACCESSORIES
32408 518-0002-01 100 480 4.25
1 4R, 6R, 6T, 4D, 6D
-
MARS NO. 70970 70971
TYPE Self Regulating Self Regulating
WATTS 32W @ 50°F · 60W @ 0°F 32W @ 50°F · 60W @ 0°F
VOLTS 120 240
Direct Replacement Crankcase Heaters for Carrier
Figure 1
32472 32474
Crankcase Heaters for Carrier
MARS NO.
CARRIER NO.
WATTS VOLTS
HEATER LENGTH IN.
LEAD LENGTH IN.
FIGURE
COMPRESSOR MODEL
32472 HT36FL379 125 120
2.75
32474 HT36FL479 125 240
2.75
60
1
EM:06DM: 306B:50EQ
68
1
EM:06DM: 30HR:30HS
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
C45
COMPONENTS
Electric Heat
Replacement Coil Kits and Accessories for Electric Heat
MARS Replacement coil kits for electric heat let you repair strip heaters quickly and economically. Each kit contains one close wound, stretch to length, resistance coil with welded terminal bolts; two each male and female ceramic terminal insulators; two each .375 and .450 inch standard ceramic bushings; two each .375 and .450 inch extra long ceramic bushings; necessary nuts, washers, and installation instructions.
Select the right MARS kit from the chart below and order one kit for each circuit to be repaired. Thermal fuse links are rated 22 amp resistor, 15 amp inducer at 120 and 240 VAC.
34602
Features:
· Welded terminal bolts for low resistance and long life
· Close wound coil, stretch to fit many applications
· Complete with bushings, insulators and hardware
MARS
WATTAGE AT
NO.
240V 208V 480V 277V
STRETCHED LENGTH
INCHES
METERS
MIN MAX MIN MAX
34602 5000 3750
--
--
44.62 127.48 1.13
3.24
34604 --
--
5000
--
61.78 176.53 1.57 4.48
34606 --
--
--
5000 59.44 169.82 1.51 4.31
34608 3500 2625
--
--
50.75 145.00 1.29
3.68
34610 --
--
3500
--
42.27 120.76 1.07 3.07
34614 2000 1500
--
--
25.90 74.01 0.66
1.88
34616 2500 1875
--
--
30.89 88.26 0.78
2.24
34620 --
--
--
2500 27.61 78.87 0.70 2.00
34622 1500 1125
--
--
17.04 48.69 0.43
1.24
34624 4500 3375
--
--
42.33 120.95 1.07
3.07
34626 --
--
4500
--
46.05 131.98 1.17 3.35
34630 --
--
2000
--
32.00 108.00 0.81 2.74
34652 6600 4950
--
--
70.56 201.59 1.79
5.12
34654 --
--
6600
--
65.39 186.71 1.66 4.74
34656 6000 4500
--
--
54.43 155.50 1.38
3.95
34658 --
--
6000
--
71.88 205.38 1.83 5.22
34660(1) 5000 3756
--
--
25.00 70.00
--
--
(1) Larger diameter coil - 5/8"
Thermal Fuse Links*
34700
34712
MARS NO.
°F
34700
204
34702
283
34704
333
34706
300
34708
300
34710
227
34712
300
*10 per pack
°C 95.56 139.45 167.22 148.89 148.89 108.33 148.89
DESCRIPTION Fuse Link Fuse Link Fuse Link Fuse Link
Fuse LinkRound Ceramic Base Fuse LinkOblong Ceramic Base Fuse LinkOblong Ceramic Base
Replacement Coil Economy Kits
34601
MARS NO.
34600
34601
DESCRIPTION 5000 Watt @ 240 V; includes coil, insulators & hardware 5000 Watt @ 240 V; includes 300° fuse link, coil, insulators & hardware
C46
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com
COMPONENTS
Relays & Sequencers
Electric Heat Sequencers
A new simple method for selecting and replacing electric heat sequencers with only five basic controls. Replace sequencers in almost any existing system.
Sequencer selection:
A. Determine the number of circuits to be switched. (Electrical rating of auxiliary switch same as main switch.) When more than one (1) sequencer is required the sequencers are to be wired in series with the last switch in each sequencer energizing the control circuit of the next sequencer.
B. Select from the chart the sequencers needed for the number of circuits to be switched. These sequencers may be wired in series to allow sequencing of virtually any number of heating elements and fans.
If the sequencers control the fan/blower circuit, the first switch (M1-M2) of each sequencer must always control the fan. This provides a fan interlock to insure that the fan will remain on until all elements are de-energized.
33222 33243
Features: · Solid State dependability · Replaces Honeywell and White-Rodgers · Ambient rated from 20°F to 160°F · Used on both separate blower and element and combination blower
and element systems · Total 24 volt control · Standard double quick-connect terminals for combination fan and
element systems · Full-load-rated auxiliary contacts · 7.2 KW combination fan and element rated contacts (23A resistive,
7A motor load) · Non-positional · Voltage and ambient self compensating positive temperature
coefficient (PTC) heater elements · Individually packaged with wiring diagrams for up to seven element
furnaces. · UL and CSA listing available
Schematic
H
H
M1
M2
33243 SPST - 1 switch
H
H
M1
M2
M3
M4
33246 DPST - 2 switches
H
H
M1
M2
H
H
M3
M4
33222 (2)SPST - 2 switches
H
H
M1
M2
M3
M4
H
H
M5
M6
33232 (1)DPST and (1)SPST - 3 switches
H
H
M1
M2
M3
M4
H
H
M5
M6
A1
A2
33233 (2)DPST - 4 switches
NO. OF SWITCHES
1 2 2 3 4
MARS NO.
33243 33246 33222 33232 33233
SWITCH TIMING: MIN-MAX IN SECONDS
SWITCH SEQUENCE
SWITCH NO.1 SWITCH NO.2 SWITCH NO.3 SWITCH NO.4 (2)
TERMINALS TERMINALS TERMINALS TERMINALS
M1 / M2
M3 / M4
M5 / M6
A1 / A2
REPLACES FIRST ON LAST ON KLIXON NO. LAST OFF FIRST OFF
ON
OFF
ON
OFF ON OFF
ON
OFF
6000AOM
(1)
1-60 1-45
6000EOM
(1)
1-60 1-45 1-60 1-45
51172-22
No. 1
No. 2 1-24 45-75 30-70 1-40
51172-32 No. 1, No. 2 No. 3 1-24 45-75 1-24 45-75 30-70 1-40
51172-33 No. 1, No. 2 No. 3, No. 4 1-24 45-75 1-24 45-75 30-70 1-40 30-70 1-40
Contact Rating Chart
VAC
RES AMPS
FLA
LRA
120
30
23
84
240
30
23
60
277
23
23
42
480
12.5
5
10
PILOT DUTY VA
672 960 775 400
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
C47
COMPONENTS
Relays & Sequencers
Thermal Time Delay Relays Sequencers
These time delay relays are used for a variety of applications in heating and air conditioning. They operate by means of a solid state PTC (positive temperature coefficient) device which heats up as current passes through it from the control circuit. This heat causes a positive, snap-acting disc to make or break the necessary contacts.
SPST
Features:
· Shock & vibration resistant internal snap action automatic reset switch mechanism assures positive make/ break action
· Non-positional
· Wide selection for any application
· Voltage and ambient compensated
· UL and CSA listed
· Used for electric heat, air conditioning, heat pumps, gas & oil furnaces, unit heaters and commercial refrigeration
DPST SPDT
Diagrams:
3 1
H
Single Pole Single Throw
2 1
3
C
H
H
Single Pole Double Throw (Contacts 1 and 3 are normally open)
4
5
1
3
H
H
Double Pole Single Throw
MARS REPLACES NO. KLIXON NO.
33215
G0-18
SWITCH TYPE
CONTROL VOLTAGE
24
DELAY (SEC.)
ON
OFF
1-60
1-45
33217
G4-9
240
20-70
20-80
33241
AOM
24
1-24
45-75
33242
AOM
SPST N.O.
24
30-75
1-40
33243
AOM
24
1-60
1-45
33244
EOM
24
1-24
45-75
33245
EOM
DPST N.O.
24
30-75
1-40
33246
EOM
24
1-60
1-45
33247 COM-21 SPDT 1 & 3 N.O.
24
1-24
15-75
33256
E4
DPST N.O.
120
20-70
20-80
33265
E4
33266
E4
DPST N.O.
240
30-110
15-65
240
20-70
20-80
33267 C4M-13 SPDT 1 & 3 N.O.
240
20-70
20-80
Electric Heat Sequencers
The MARS heat sequencers are used in a variety of applications, including electric furnaces, baseboard heaters, heat pump blower control and heating element control. The sequencers stage electric heat to prevent circuit overload. These units operate by means of a PTC (positive temperature coefficient). The PTC is self current limiting, ensuring stable switching action over a wide rangeof voltages.
Features: · Solid state dependability · Replaces Honeywell, White
Rodgers, and Klixon · 12.5A to 25A contact ratings · Quick connect terminals · Various mounting positions · Shock & vibration resistant · Ambient rated from -50ºF to
165ºF · Full-load rated auxiliary
contacts
33841 33844
Single Load Contact Ratings
RESISTIVE (NON-INDUCTIVE)
VAC
WATTS
AMPS
MOTOR RATINGS (INDUCTIVE)
FULL LOAD
LOCKED ROTOR
PILOT DUTY
120
3000
25
10A
60A
125VA
240
6000
25
5A
30A
125VA
480
6000
12.5
3A
18A
480VA
Combined Load Ratings: 30A @ 240VAC - Total: 23A non-inductive + 7FLA / 42LRA inductive Life at rated current: 10,000 cycles
MARS NO.
TIM.
SW.
M1-M2 M3-M4 M5-M6 M7-M8 M9-M10 M1-M2 M3-M4 M5-M6 M7-M8
M9M10
33841 1 1 1-20 -
-
-
- 40-110 -
-
--
33842 1 1 - - 30 - 90 -
-
- - 1-30 - -
33844(1) 1 2 1-20 g 1-20 -
-
- 40-110g40 - 110 -
--
33845 1 2 -
- 30-90 g 30-90 -
-
- 1-30 g 1-30 -
33832(1) 2 3 1-110 g 1-110 1-110 -
- 1-110 g 1-110 1-110 - -
33833(1) 2 4 1-110 g 1-110 1-110 g 1-110 - 1-110 g 1-110 1-110 g1-110 -
33848(1)(2) 4 5 1-160 g 1-160 1-160 1-110 1-160 1-160 g1-160 1-160 1-160 1-160
(1) M1-M2 and M3-M4 are always first switches to turn ON and to turn OFF. All other switches are random ON and random OFF (2) #33848 - switch contacts designated F1-F2 instead of M1-M2
g These contacts switch simultaneously ON TIME Elapsed time to make contacts after heater is energized (Min. to Max.) OFF TIME Elapsed time to make contacts after heater is de-energized (Min. to Max.) OFF Timings determined after PTC heater has been electrified for a total of 5 minutes.
C48
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com
COMPONENTS
Fan & Limit Disc Thermostats
Heating Applications
MARS Series 390 thermostats are designed for quick on-the-job replacements. One thermostat, when used in conjunction with only one listed, can solve almost any mounting problems you encounter.
Our thermostats have been carefully selected to cover the widest temperature ranges with the fewest models.
Features:
· Widest range of replacements in the industry
· UL and CSA listings available
Electrical Rating
Terminals Terminals*
1-3
1-2
FL Amps
120v
10
5.8
240v
5
2.9
Res. Amps 120v
25
10
240/277v 25
5
Pilot Duty 120/240/277v 125va 125va
*For Spdt Thermostats
Manual
SPDT
Fan & Limit
Fan Switches - Close On Temperature Rise
MARS NO.
KLIXON TEMP. CODE
TEMPERATURE °F OPEN CLOSE
39006 F110-2
90
110
39007 F120-2 100
120
39008 F130-2 110
130
39009 F140-2 120
140
39010 F150-2 130
150
39011 F160-2 140
160
Manual Reset Limit SwitchesOpen On Temperature Rise
MARS NO.
REPLACES TEMPERATURE
KLIXON
°F
TEMP. CODE OPEN °F
39099
MR125
125
39037
MR140
140
39038
MR150
150
39039
MR160
160
39095
MR170
170
39096
MR180
180
39097
MR190
190
39098
MR200
200
39040
MR210
210
39042
MR240
240
39043
MR300
300
Limit Switches - Open On Temperature Rise
MARS NO.
KLIXON TEMPERATURE °F TEMP. CODE CLOSE OPEN
39086 L125-2 105
125
39087 L130-4
90
130
39018 L140-4 100
140
39019 L150-4 110
150
39020 L160-4 120
160
39021 L170-4 130
170
39022 L180-4 140
180
39023 L190-4 150
190
39024 L200-4 160
200
39025 L210-4 170
210
39026 L220-4 180
220
39027 L230-4 190
230
39028 L240-4 200
240
39029 L250-4 210
250
39030 L270-4 230
270
39031 L300-4 260
300
39033 L350-4 310
350
Single Pole Double Throw Switches
MARS NO.
KLIXON TEMP. CODE
TEMPERATURE °F
1-2 OPEN 1-2 CLOSE
OPEN
CLOSE
39078 D140-2 120
140
39045 D150-2 130
150
39081 D170-2 150
170
Adjustable Fan or Limit Thermostats
MARS adjustable fan or limit thermostats let you reduce inventory and still have on hand the most popular thermostat ratings.
MARS adjustable thermostats Are easily set for the desired temperature by turning the indicator dial built into the control. Each MARS adjustable thermostat features integral 2 hole oval mounting flanges.
Features: · Easy dial adjustment · Six controls cover most
requirements · Intergral oval flange · UL and CSA listings available
MARS NO.
39205 39210 39220 39225 39230 39235
TYPE
Fan Fan Limit Limit Limit Limit
RANGE °F
90-130 140-180 135-175 175-215 210-250 250-290
39205
DIFF. °F
20 20 40 40 40 40
SWITCHING ACTION
Close on rise Close on rise Open on rise Open on rise Open on rise Open on rise
Cross Reference Information
GEM NO. MARS NO. WHITE-RODGERS NO. MARS NO.
AT 012 AT 013 AT 014 AT 015 AT 021 AT 022
39220 39225 39230 39235 39205 39210
3F05-1 3F05-2 3L05-1 3L05-2 3L05-3
39205 39210 39220 39225 39230
MARS 2
35205 35220 35225 35230 35235
MARS NO.
39205 39220 39225 39230 39235
Cross Reference Information
WR
MARS
NO. REPLACEMENT
3F01-110 3F01-120 3F01-130 3F01-140 3F01-150 3F01-160 3F01-180 3F01-200 3F01-350
39006 39007 39008 39009 39010 39011 39112 39113 39017
WR
MARS
NO. REPLACEMENT
3L01-120 3L01-130 3L01-140 3L01-180 3L01-190 3L01-200 3L01-230 3L01-250 3L01-300 3L01-350 3L01-550
39086 39087 39018 39022 39023 39024 39027 39029 39031 39033 39036
WR NO.
3L02-160 3L02-170 3L02-180 3L02-190 3L02-200
MARS REPLACEMENT
39039 39095 39096 39097 39098
3L03-140 3L03-190 3L03-325
39078 39147 39093
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
C49
COMPONENTS
Fan & Limit Disc Thermostats
Electric Heat High Limit Thermostats
MARS electric heat high limit thermostats are designed for easy accurate replacement of OEM thermostats on electric furnaces. Temperature ratings and differentials have been careful selected for safe operation.
MARS electric heat high limit thermostats feature an exposed matte finish disc for fast response. Easy matching of OEM mountings using the intergal round flange or accessory oval flange.
Features:
· Exposed matte finish disc for fast response
· Twelve models replace most popular OEM thermostats
· Individually bagged with instructions
· UL and CSA listings available
39310
TEMPERATURE °F
MARS NO.
OPEN
CLOSE
DIFFERENTIAL
39310 110
90
20
39312 120
100
20
39314 130
100
30
39316 140
100
40
39318 145
105
40
39320 150
110
40
39324 160
120
40
39326 170
130
40
39328 180
140
40
39330 190
150
40
Pro-Series Heating Service Kit
MARS has selected the most popular fan and limit switches used in heating applications. Each switch has an integral small oval flange to duplicate the most popular mounting. UL and CSA listings available.
39008
MARS NO.
39008 39009 39010 39011 39022 39023 39024
SWITCH TYPE
Fan Fan Fan Fan Limit Limit Limit
KLIXON TEMP. CODE
F130-2 F140-2 F150-2 F160-2 L180-4 L190-4 L200-4
TEMPERATURE °F
CLOSE
OPEN
130
110
140
120
150
130
160
140
140
180
150
190
160
200
TEMPERATURE °C
CLOSE
OPEN
54
43
60
49
66
54
71
60
60
82
66
88
71
93
Home Laundry Applications
MARS has carefully selected the most popular multi-purpose thermostats for home laundry and drier equipment. MARS Operating Limit Thermostats range from 125°F to 180°F and have narrow differentials (20°F).
Features: · UL and CSA listings available.
39086
Operating Limit Thermostats -- Open On Temperature Rise
MARS NO.
39086 39055 39051 39048
KLIXON TEMP. CODE
L125-2 L130-2 L150-2 L180-2
TEMP °F-OPEN
125 130 150 180
TEMP. °F-CLOSE
105 110 130 160
MARS Thermocouples
MARS universal replacement thermocouples are fully equipped with fittings and necessary hardware for quick and easy installation.
Each kit is packaged on a display card for easy identification.
Features:
· High temperature stainless steel element for long life and dependable operation
· Fully equipped with fittings and necessary hardware for quick and easy installation
· Individually display packaged for protection and easy identification
72248 Adapter fittings with each kit
MARS NO.
72218 72224 72230 72236 72248
MODEL NO.
TC-18P TC-24P TC-30P TC-36P TC-48P
LENGTH INCHES
18 24 30 36 48
C50
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com
COMPONENTS
MARS Universal Silicon Nitride Igniter
MARS Universal Silicon Nitride Igniter is designed to replace over 100 silicon nitride igniter applications. The universal bracket kit is used in a simple series of combinations for a quick and easy installation. Extremely low iron content makes the MARS Universal Silicon Nitride Igniter very durable and reliable. Low energy consumption makes it perfect for any 120 VAC application.
Features: · Gas fired forced air furnaces and boilers · Easy to install · Universal bracket fits most furnaces · Fits over 100 applications
MARS NO.
68040
DESCRIPTION Universal SiN Round Silicone Nitride Igniter
Specifications: · Input voltage 120vac · Time to ignition temperature: 16
seconds · CSA certified · Steady current 1.3 amps
(± 0.3 amps @ 120v)
Hot Surface Igniters
Gas Furnace Igniters
· Compatible with 17, 34, and 45 second warm-up modules · Full 115/120 volt rated (no step down module required for silicon nitride) · Wire nuts or OEM plugs and mounting hardware included · New laminated pictorial cross reference and contractor tri-folds available
19" leads with sleeving and connector 67909
5.5" leads with wire nuts 67916
Flat silicon carbide: The most economical solution. Silicon nitride: The newest technology is virtually indestructible.
Direct Replacements
FLAT SILICON CARBIDE
67914 67915 67916 68017 67917 67925 67918 67919 67920 68016 68013 68014 67915 68015 67909 67921 67924 67923
INDUSTRY RECOGNIZED REFERENCE
41-401 41-402 41-403 41-404 41-405 41-406 41-407 41-408 41-409 41-410 41-411 41-412/41-414 41-238/41-242 Rheem 62-22669-92 Coleman 1474-051P / 052P Lennox 33J37 Goodman B1401015 / B1401018S York 025-32625-000
5.5" leads with wire nuts 67917
67920
67921 67924
68015
Universal
FLAT SILICON CARBIDE 67900
N/A
SILICON NITRIDE
N/A
68040
SUPCO SIG1100 SSN2000
WHITE-RODGERS 21D64-2
67900
®
marsdelivers.com
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
67914 19" leads with wire nuts 67915
67918 67919
67923 67925 68016
C51
COMPONENTS
Flame Sensors
Flame Sensors
MARS flame sensors are direct OEM replacements. False shutdowns can occur in gas furnaces due to a built up carbon on the flame rod. Incorrect cleaning procedures can also damage the flame rod. Replacing a flame sensor that has triggered a false shutdown is the best preventative maintenance and eliminates nuisance service calls.
· Direct OEM Replacements · Improved Service Life · OEM Mounting Brackets · Ceramic Insulators
MARS No.
67680 67681 67682 67683 67684 67685 67686 67687 67688 67689
Replaces OEM
Goodman Source 1 Source 1 Goodman
Allied Source 1 Source 1 Source 1 Goodman Source 1
OEM Part Number
10735201 SI-02537499000 SI-02530788700
0130F00010 44L48
SI-02535306000 SI-02527773700 SI-02535354000
B1172601 SI-02530802000
67680 67681 67682 67683 67684
67685 67686 67687 67688 67689
C52
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com
®
marsdelivers.com