Layout 1

Components

PDF preview unavailable. Download the PDF instead.

Components ?MOD=AJPERES&CONVERT TO=url&CACHEID=ROOTWORKSPACE-16af6595-38a8-49cc-9045-fe3ffc649547-nxAYRJJ
Components
®
Delivering Confidence

COMPONENTS

Table of Contents

Description

Page No.

Capacitors Accessories for Capacitors . . . . . . . . . . . . . . . . . . . . . . .C-9 Motor Run Capacitors . . . . . . . . . . . . . . . . . .C-5 ­ C-8, C-10 Motor Start Capacitors . . . . . . . . . . . . . . . . . . . . . . . . . . .C-3 Turbo 200TM Universal Motor Run & Start Capacitors . . . . . . . .C-4
Compressor and Crankcase Heaters . . . . . . . . .C-44 ­ C-45 Condensate Pumps . . . . . . . . . . . . . . . . . . . . . . .C-27 ­ C-28 Contactors
MARS 780 Dual Purpose Contactors . . . . . . . .C-11 ­ C-16 Furnas NEMA Contactors & Starters . . . . . . . . . . . . . .C-17 GE Definite Purpose Contactors . . . . . . . . . . . . . . . . . .C-18 Magnetic Line Contactors . . . . . . . . . . . . . . . . . . . . . . .C-20 MARS Definite Purpose Contactors . . . . . . . . . . . . . . .C-19 Universal Contactor Enclosure . . . . . . . . . . . . . . . . . . .C-18 Crankcase Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-44 Defrost Thermostats . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-41 Electric Heat Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-46 Fan Centers MARS Fan Centers . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-20 Fan & Limit Thermostats . . . . . . . . . . . . . . . . . .C-49 ­ C-50 Flame Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-52 Heat Pump Thermostats . . . . . . . . . . . . . . . . . . . . . . . . .C-43 Hot Suface Igniters (Pilot Burners) . . . . . . . . . . . . . . . .C-51 Klixon Motor Protectors . . . . . . . . . . . . . . . . . . . . . . . . .C-40

Description

Page No.

Klixon Pressure Switches . . . . . . . . . . . . . . . . . . . . . . . .C-42 Klixon Thermostats . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-41 Leak Detectors / Renewal Parts . . . . . . . . . . . . . . . . . . .C-36 MARS Motor Protectors . . . . . . . . . . . . . . . . . . . . . . . . .C-39 MARS Pressure Switches . . . . . . . . . . . . . . . . . .C-42 ­ C-43 Relays
Current Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-33 Enclosed Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-33 General Purpose Relays . . . . . . . . . . . . . . . . . . . . . . . .C-31 General Purpose Switching Relays . . . . . . . . . .C-31 ­ C-32 MARS Potential Relays . . . . . . . . . . . . . . . . . . .C-34 ­ C-35 Sequencers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-47 ­ C-48 Solid State Motor Starting Devices . . . . . . . . . . . . . . . .C-37 Solid State Timers . . . . . . . . . . . . . . . . . . .C-37 ­ C-38, C-39 Start Assists . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-29 ­ C-30 Surge Protection Devices . . . . . . . . . . . . . . . . . . .C-26, C-27 Thermocouples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-50 Transformers GE IP Core & Coil Transformers . . . . . . . . . . . . . . . . . .C-23 Jard Transformers . . . . . . . . . . . . . . . . . . . . . . .C-24 ­ C-25 MARS Transformers . . . . . . . . . . . . . . . . . . . . .C-21 ­ C-23

C­2

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com

COMPONENTS

Motor Start Capacitors

Electrolytic Capacitors for Motor Starting Applications

Start capacitor case dimensions chart. Capacitor accessories on page C-9.
Features:
· The largest assortment of replacements in the industry!
· Smallest dimensions for general replacements.
· Hermetically sealed black Bakelite case permanently protects the capacitor from oil, dirt, grease or moisture.
· New and improved terminal construction capable of withstanding increased heat. This terminal will generate less heat when applied under severe hot humid environment.
· 50/60 Hz
· UL/ULc

®
Blue BoxTM

110/125 Dual Voltage AC

MARS NO.
11002 11003 11004 11005 11006 11007 11008 11009 11010 11112 11011 11013 11014 11015 11016 11017 11018 11019 11020 11021 11022 11023 11024 11071 11025 11026 11027 11047 11028 11072 11029 11073 11030 11074

MICROFARAD MIN - MAX.
21-25 25-30 30-36 36-43 43-56 56-72 72-88 88-108 108-130 124-156 130-156 145-175 161-193 189-227 200-240 216-259 233-292 270-324 300-360 324-388 340-408 378-440 400-480 430-516 460-552 540-648 590-708 645-774 708-850 815-970 829-995 850-1020 1000-1200 1290-1548

CASE SIZE
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 4 4 4 4 4 4 4 7 7

MARS suggests applying a bleed resistor (MARS PN 93007) on start capacitors used in conjunction with starting relays
*Capacitors may be put in different case sizes occasionally, but will not be larger than those stated.

165 Volts AC
MARS NO.
11075 11076 11077 11031 11032 11033 11034 11078 11035 11036 11079 11080 11037 11081 11082 11083

MICROFARAD MIN - MAX.
72-88 88-108 108-130 124-149 145-175 161-193 189-227 216-259 233-292 270-324 340-408 378-455 400-480 540-648 710-850 810-972

220/250 Dual Voltage AC

MARS NO.
11038 11039 11040 11041 11042 11043 11084 11137 11044 11045 11046 11148 11049 11050 11051 11052 11053 11054 11085 11086 11087 11088 11089 11090 11091

MICROFARAD MIN - MAX.
21-25 25-30 30-36 36-43 43-56 56-72 59-71 64-77 72-88 88-108 108-130 124-156 145-175 161-193 189-227 216-259 233-292 270-324 280-336 320-384 340-408 378-455 400-480 430-516 630-750

330 Volts AC
MARS NO.
11055 11056 11057 11058 11059 11060 11160 11061 11062 11063 11064 11165 11092 11066 11067 11068 11069 11070 11093

MICROFARAD MIN - MAX.
21-25 25-30 30-36 36-43 43-56 56-72 64-77 72-88 88-108 108-130 130-156 124-156 135-162 145-175 161-193 189-227 216-259 270-324 300-360

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

CASE SIZE
1 1 1 1 1 1 1 4 4 4 4 4 4 4 7 7
CASE SIZE
1 1 1 1 1 1 1 4 4 4 4 4 4 6 6 6 6 6 7 7 7 7 7 7 8
CASE SIZE
2 2 2 2 4 4 4 4 4 7 7 7 7 7 7 7 7 7 7
C­3

COMPONENTS

TurboTM Products
The Turbo® 200 Family Products
Universal Run & Start Capacitor Replacement. Have the right capacitor for the job every time. The perfect solution for off hour emergency service calls.
Universal HardStart Replacement. One "2-Wire" Turbo® Easy-Start Hardstart can replace any one of four compressor hardstart kits on the market.
12200 and 12300 feature a CPT (Compressor Protector Terminal) for use
with hard start kits. The CPT acts like a kill switch and protects the compressor in the event of
a capacitor failure.

12100 Turbo® 200 Mini

12500 Turbo® 200 Mini - Oval

12200 Turbo® 200

12300 Turbo® 200X

11200 TurbolyticTM 50

11100 TurbolyticTM JR

86150 TurboMeterTM

MARS NO. 12100 12500 12200 12300 11200 11100

DESCRIPTION
Turbo® 200 Mini Turbo® 200 Mini - Oval
Turbo® 200 Turbo® 200 X TurbolyticTM 50 Universal Motor Start Capacitor TurbolyticTM JR

86150

TurboMeterTM See the dual values develop simultaneously on the screen as you create the ratings needed.

MICROFARAD
2.5 mfd - 15 mfd, 370V or 440V
2.5 mfd - 15 mfd, 370V or 440V
2.5 mfd - 67.5 mfd, 370V or 440V
5.0 mfd - 97.5 mfd, 370V or 440V
23 mfd - 302 mfd, 125V to 330V
23 mfd - 208 mfd, 125V to 330V

12600

Turbo® Easy-Start Hardstart

Up to 1 ton 108-130 mfd 1 to 2 tons 189-227 mfd 2.5 to 3 tons 233-280 mfd 3.5 to 5 tons 270 to 324 mfd

MARS Capacitor Tester
Features: · Easy to use · 9V battery and test leads included · Low battery indicator

MARS NO. RANGE RESOLUTION

200 pF

0, 1pF

65746

2000 pF 20 nF 200 nF 2 nF
20 µF
200 µF
2000 µF
20 mF

1 pF 10 pF 100 pF 1 nF
10 nF
100 nF
1 µF
10 µF

ACCURACY TEST FREQUENCY
± (0.5% rdg + 1 dgt + 0.5 pF)

± (0.5% rdg +1 dgt)

820Hz 82 Hz

± (2.0% rdg. + 1dgt) ± (4.0% rdg. + 1dgt)

8.2 Hz

12600 Turbo® Easy-Start
C­4

65746
Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com

COMPONENTS

Motor Run Capacitors

Single Section Run Capacitors

Capacitor accessories on page C-9.

Features:
· MARS offers the widest selection of ratings in the industry
· Non-PCB capacitors
· Physical interrupter makes our capacitors safe
· Perfect for general replacements--smallest dimensions available
· UL and CSA listings available
· 50/60 Hz

12002

12092

NORMAL

FAIL SAFE MODE

PHYSICAL INTERRUPTER

12026

12102
®
Blue BoxTM

Single Section 370 Volt Oval

MARS NO.
12002 12003 12004 12005 12006 12007 12008 12009 12010 12012 12014 12015 12017 12018 12021 12023 12025 12024 12087 12011 12089 12090

MICROFARAD
2 3 4 5 6 7.5 10 12.5 15 17.5 20 25 30 35 40 45 50 55 60 65 70 80

BASE
A A A A A A A A A A C C C C C C C C C C C D

HEIGHT IN.
1.500 1.500 1.500 1.500 1.500 2.375 2.625 3.000 3.750 3.750 2.375 2.625 2.625 3.000 3.750 3.750 3.750 4.250 4.750 4.750 4.750 3.750

Single Section 370 Volt Round

MARS NO.

MICROFARAD

12092

2

12093

3

12094

4

12095

5

12096

6

12097

7.5

12098

10

12099

12.5

12210

15

12211

16

12212

17.5

12214

20

12215

25

12217

30

12218

35

12221

40

12223

45

12225

50

12226

55

12227

60

12128

65

12229

70

12199

80

12116

100

Single Section 440/370 Volt Oval

MARS NO.

MICROFARAD

12026

2

12019

2.5

12027

3

12028

4

12029

5

12030

6

12031

7.5

12032

10

12033

12.5

12034

15

12036

17.5

12037

20

12040

25

12041

30

12043

35

12045

40

12048

45

12049

50

12050

55

12051

60

12052

65

12130

70

12135

75

12140

80

Single Section 440/370 Volt Round

MARS NO.
12102 12103 12104 12105 12106 12107 12232 12233 12234 12236 12237 12240 12241 12243 12245 12248 12251 12252 12254 12357 12258 12259 12068

MICROFARAD
2 3 4 5 6 7.5 10 12.5 15 17.5 20 25 30 35 40 45 50 55 60 65 70 80 90

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

BASE
M M M M M M M M M M M M M M M M N N N N N N N P
BASE
A A A A A A A A A C C C C C C C C C C D D D D D
BASE
M M M M M M M M M M M M N N N N P P P P P P P

HEIGHT IN.
2.000 2.000 2.000 2.000 2.000 2.000 2.000 2.000 2.375 2.375 2.375 2.625 3.000 3.000 3.750 3.750 3.375 3.750 3.750 4.750 4.750 4.750 4.750 4.750
HEIGHT IN.
1.500 1.500 2.000 2.000 2.375 2.375 2.625 3.750 3.750 2.375 2.375 2.625 3.000 3.750 3.750 4.750 4.750 4.750 4.750 3.750 3.750 3.750 3.750 4.750
HEIGHT IN.
2.000 2.000 2.000 2.000 2.000 2.000 2.375 2.375 2.625 2.750 3.000 3.750 3.375 3.750 3.750 4.750 3.375 3.750 3.750 3.750 4.750 4.750 4.750
C­5

COMPONENTS

Motor Run Capacitors

Dual Section Motor Run Capacitors

Dual section run capacitors are used primarily to serve two microfarad applications. They can, however, by making various combinations of parallel connections, be used to obtain many other microfarad ratings.
Capacitor accessories on page C-9.
Features: · MARS offers the widest
selections of ratings in the industry
· Non-PCB capacitors
· Physical interrupter makes our capacitors safe
· Perfect for general replacements-- smallest dimensions available
· UL and CSA listings available · 50/60 Hz

Dual Section 370 Volt Oval

MARS NO.

MICROFARAD

12141 12056 12057 12058 12059 12060 12061 12062 12063 12064 12164 12142 12065 12066 12143 12131 12167 12133 12144 12145 12069 12146 12147 12148 12071 12072 12149 12150 12151 12158 12171 12152 12134 12173 12174 12153 12136 12137 12138 12154 12155 12139 12156 12157 12159 12163 12123

15/3 15/4 15/5 15/10 17.5/4 17.5/5 20/3 20/4 20/5 20/10 20/15 25/3 25/4 25/5 25/7.5 25/8 25/10 25/15 30/3 30/4 30/5 30/7.5 30/10 35/3 35/4 35/5 35/7.5 35/10 40/3 40/4 40/5 40/7.5 40/10 45/3 45/5 45/7.5 45/10 45/15 50/5 55/5 55/7.5 60/5 60/7.5 60/10 65/5 80/5 80/7.5

12141
®
Blue BoxTM

NORMAL

FAIL SAFE MODE

PHYSICAL INTERRUPTER

BASE
C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C D C C D D D

HEIGHT IN.
2.625 2.625 2.625 3.000 2.375 2.375 2.625 2.625 2.625 2.625 4.750 2.625 2.625 2.625 2.625 3.000 3.000 3.000 3.000 3.000 3.000 3.000 3.375 3.000 3.750 3.750 3.000 3.750 3.750 3.750 3.750 3.750 3.750 3.750 3.750 3.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750

Dual Section 370 Volt Round

MARS NO.
12121 12122 12203 12204 12205 12206 12207 12260 12016 12208 12209 12242 12175 12261 12262 12213 12244 12263 12264 12224 12228 12039 12082 12231 12266 12235 12238 12074 12267 12178 12268 12246 12073 12247 12269 12249 12250 12075 12191 12192 12239 12193 12194 12067 12076 12195 12196 12265 12042 12053 12054 12055 12044 12046 12084 12197 12198 12201 12202 12129 12230 12222

MICROFARAD
15/3 15/4 15/5 15/10 17.5/4 17.5/5 20/4 20/5 20/7.5 20/10 20/15 25/3 25/4 25/5 25/7.5 25/10 30/3 30/4 30/5 30/7.5 30/10 30/15 35/3 35/4 35/5 35/7.5 35/10 40/3 40/4 40/5 40/7.5 40/10 45/3 45/4 45/5 45/7.5 45/10 50/3 50/5 50/7.5 50/10 55/5 55/7.5 55/10 60/3 60/5 60/7.5 60/10 65/5 70/5 70/7.5 70/10 75/5 75/7.5 75/10 80/5 80/7.5 80/10 80/12.5 85/5 85/7.5 85/10

BASE
N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N P N N P N P P N N N P P N P N P P P P P P P P P P P P P

C­6

Toll Free (800) 445-4155 · Fax (631) 348-7160

www.marsdelivers.com

HEIGHT IN.
3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.875 3.875 3.125 3.875 3.125 3.875 3.875 3.875 3.875 3.875 3.875 3.875 3.875 3.875 3.875 3.875 3.125 3.875 3.125 3.875 4.75 4.75 4.75 3.875 3.875 4.75 3.125 4.75 3.875 3.875 3.875 3.875 3.875 3.875 3.875 3.875 3.875 4.75 4.75 4.75 4.75
®
marsdelivers.com

COMPONENTS

Motor Run Capacitors

Capacitor Base Dimensions
12165
®
Blue BoxTM

Dual Section 440/370 Volt Oval

MARS NO.
12360 12165 12170 12270 12271 12177 12180 12083 12184 12182 12183 12186 12181 12187 12038 12035 12085 12179 12185 12188 12176 12272 12080 12086 12189 12273 12190 12274 12108 12013 12275 12276 12109 12110 12101 12297 12298

MICROFARAD
5/5 10/5 10/10 15/4 15/5 15/10 20/5 20/15 25/5 25/7.5 25/10 25/15 30/4 30/5 30/7.5 30/10 35/3 35/4 35/5 35/7.5 35/8.5 35/10 40/3 40/5 40/7.5 40/10 45/5 45/7.5 50/5 50/7.5 55/5 55/10 60/5 60/7.5 65/10 80/5 80/7.5

BASE
C C C C C C C D D C C D C D C C C C C C C C C C C C D C D C D D D D D D D

HEIGHT IN.
2.625 3.125 3.125 2.625 2.625 3.750 3.375 3.000 3.000 3.750 3.750 3.000 3.750 3.750 3.750 3.750 4.750 3.750 4.750 3.750 3.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 5.750 5.750

Dual Section 440/370 Volt Round

MARS NO.
12111 12118 12356 12350 12115 12354 12351 12112 12353 12355 12278 12279 12113 12114 12126 12120 12281 12282 12352 12077 12070 12283 12119 12284 12091 12078 12285 12286 12220 12287 12088 12079 12219 12288 12127 12289 12172 12290 12291 12124 12253 12292 12293 12299 12160 12294 12295 12296 12161 12358 12359 12162 12255 12166 12169 12168 12125 12047 12257 12216 12117 12022 12020 12001

MICROFARAD
10/5 15/5 15/10 17.5/5 20/5 20/7.5 20/10 20/15 25/3 25/4 25/5 25/7.5 25/10 25/15 30/3 30/4 30/5 30/7.5 30/10 35/3 35/4 35/5 35/6 35/7.5 35/10 40/3 40/4 40/5 40/6 40/7.5 40/10 45/3 45/4 45/5 45/6 45/7.5 45/10 50/5 50/7.5 50/10 50/12.5 55/5 55/7.5 55/10 60/3 60/5 60/7.5 60/10 60/12.5 65/5 65/7.5 65/10 70/5 70/7.5 70/10 75/5 75/7.5 75/10 80/5 80/7.5 80/10 85/5 85/7.5 85/10

BASE
N N N N N N N N N N N N N N N N N N N N N N N P N P P P N P N P N P N N P P P P P P P P P P P P P P P P P P P P P P P P P P P P

HEIGHT IN.
3.125 3.125 3.125 3.125 3.125 3.125 3.875 3.875 3.875 3.875 3.875 3.875 3.625 3.875 3.875 3.875 3.875 3.875 4.750 3.875 3.875 3.875 4.750 3.875 4.750 3.125 3.125 3.125 4.750 3.875 4.750 3.875 3.750 3.875 4.750 3.875 3.875 3.875 3.875 3.875 3.875 3.875 3.875 3.875 4.750 3.875 3.875 3.875 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.750 4.875 4.750 4.750 4.750 4.750 4.750

Base Dimension Key - Oval

KEY

DEPTH IN.

WIDTH IN.

A

1.31

2.16

C

1.91

2.91

D

1.97

3.66

Base Dimension Key - Round

DESCRIPTION
oval fan size oval oval

KEY

DEPTH IN.

M

1.75

N

2.00

P

2.50

MOUNTING STRAP
93031 93032 93033

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

C­7

COMPONENTS

USA Motor Run Capacitors

MARS USA Capacitors

Features: · Product of USA · Tested and approved by every
major US motor company and compressor company · 440/370 Dual Voltage Rated · Non-PCB capacitors · Physical interrupter makes our capacitors safe · Meets EIA-456A Test Standard (simulates 60,000 hours of operation) · Meets Tecumseh H-115 · OEM Grade · CSA approved and UL recognized · 5 year warranty

Single Section 370 Volt Oval

Single Section 370 Volt Round

MARS USA NO. 14002
14003
14004
14005

DESCRIPTION
2 MFD 370V OVL 3 MFD 370V OVL 4 MFD 370V OVL 5 MFD 370V OVL

BASE HEIGHT
A 1.50 A 1.50 A 1.50 A 1.50

MARS USA NO. 14098
14210
14212

DESCRIPTION BASE HEIGHT
10 MFD 370V RND M 2.00 15 MFD 370V RND M 2.38 17.5 MFD 370V RND M 2.38

14006 6 MFD 370V OVL

A 1.50 14214 20 MFD 370V RND M 2.65

14007 7.5 MFD 370V OVL A 2.38 14215 25 MFD 370V RND M 3.00

14008 10 MFD 370V OVL A 2.63 14217 30 MFD 370V RND M 3.00

14009 12.5 MFD 370V OVL A 3.00 14218 35 MFD 370V RND M 3.75

14010 15 MFD 370V OVL A 3.75 14012 17.5 MFD 370V OVL A 3.75 14014 20 MFD 370V OVL C 2.38 14015 25 MFD 370V OVL C 2.63 14017 30 MFD 370V OVL C 2.63 14018 35 MFD 370V OVL C 3.00 14021 40 MFD 370V OVL C 3.75

14821 40 MFD 370V RND M 3.75 14823 45 MFD 370V RND N 3.38 14225 50 MFD 370V RND N 3.75 14226 55 MFD 370V RND N 3.75 14227 60 MFD 370V RND N 4.75 14229 70 MFD 370V RND N 4.75

14023 45 MFD 370V OVL C 3.75 14199 80 MFD 370V RND N 4.75

14025 50 MFD 370V OVL C 3.75

14089 70 MFD 370V OVL C 4.75 Single Section 440/370 Volt Round

14090 80 MFD 370V OVL

D 3.75 MARS USA

DESCRIPTION BASE HEIGHT

Single Section 440/370 Volt Oval NO.

MARS

14105 5 MFD 440/370V RND M 2.00

USA

DESCRIPTION BASE HEIGHT 14107 7.5 MFD 440/370V RND M 2.00

NO.

14232 10 MFD 440/370V RND M 2.38

14027 3 MFD 440/370V OVL A 2.00 14833 12.5 MFD 440/370V RND M 2.38 14028 4 MFD 440/370V OVL A 2.00 14029 5 MFD 440/370V OVL A 2.38 14234 15 MFD 440/370V RND M 2.63

14030 6 MFD 440/370V OVL A 2.38 14237 20 MFD 440/370V RND M 3.00

14031 7.5 MFD 440/370V OVL A 2.63 14240 25 MFD 440/370V RND M 3.75

14032 10 MFD 440/370V OVL A 3.75 14241 30 MFD 440/370V RND N 3.38

14033 12.5 MFD 440/370V OVL A 3.75 14243 35 MFD 440/370V RND N 3.75
14034 15 MFD 440/370V OVL C 2.38 14245 40 MFD 440/370V RND N 3.75 14037 20 MFD 440/370V OVL C 2.63 14248 45 MFD 440/370V RND N 4.75 14040 25 MFD 440/370V OVL C 3.00 14041 30 MFD 440/370V OVL C 3.38 14251 50 MFD 440/370V RND P 3.38 14043 35 MFD 440/370V OVL C 3.75 14252 55 MFD 440/370V RND P 3.75
14045 40 MFD 440/370V OVL C 4.75 14256 65 MFD 440/370V RND P 3.75

14048 45 MFD 440/370V OVL C 4.75 14254 60 MFD 440/370V RND P 3.75

14049 50 MFD 440/370V OVL C 4.75 14258 70 MFD 440/370V RND P 4.75
14050 55 MFD 440/370V OVL C 4.75 14259 80 MFD 440/370V RND P 4.75 14051 60 MFD 440/370V OVL D 3.75

14140 80 MFD 440/370V OVL D 4.75

Dual Section 370 Volt Oval

MARS USA NO.

DESCRIPTION BASE HEIGHT

14066 25/5 MFD 370V OVL C 2.63

Dual Section 440/370 Volt Round

MARS USA NO.

DESCRIPTION

BASE HEIGHT

14353 25/3 MFD 440/370V RND N 3.88

14069 30/5 MFD 370V OVL C 3.00 14278 25/5 MFD 440/370V RND N 3.88

14072 35/5 MFD 370V OVL C 3.75 14279 25/7.5 MFD 440/370 RND N 3.88

14171 40/5 MFD 370V OVL C 3.75 14126 30/3 MFD 440/370V RND N 3.88

14174 45/5 MFD 370V OVL C 3.75 14281 30/5 MFD 440/370V RND N 3.88

14282 30/7.5 MFD 440/370V RND N 3.88

Dual Section 440/370 Volt Oval

14077 35/3 MFD 440/370V RND N 3.88

MARS USA

DESCRIPTION

BASE HEIGHT 14070 35/4 MFD 440/370V RND N 3.88

NO.

14283 35/5 MFD 440/370V RND N 3.88

14184 25/5 MFD 440/370V OVL C 3.75 14284 35/7.5 MFD 440/370V RND P 3.88

14187 30/5 MFD 440/370V OVL D 3.75 14091 35/10 MFD 440/370V RND N 4.75

14185 35/5 MFD 440/370V OVL C 4.75 14078 40/3 MFD 440/370V RND P 3.13

14188 35/7.5 MFD 440/370V OVL C 3.75 14286 40/5 MFD 440/370V RND P 3.13

14086 40/5 MFD 440/370V OVL C 4.75 14287 40/7.5 MFD 440/370V RND P 3.88

14189 40/7.5MFD 440/370V OVL C 4.75 14190 45/5 MFD 440/370V OVL D 4.75 14297 80/5 MFD 440/370V OVL D 5.75 14298 80/7.5MFD 440/370 OVL D 5.75

14088 40/10 MFD 440/370V RND N 4.75 14079 45/3 MFD 440/370V RND P 3.88 14288 45/5 MFD 440/370V RND P 3.88 14289 45/7.5 MFD 440/370V RND N 3.88 14172 45/10 MFD 440/370V RND P 3.88

Dual Section 370 Volt Round

MARS USA NO.

DESCRIPTION BASE HEIGHT

14260 20/5 MFD 370V RND N 2.63

14261 25/5 MFD 370V RND N 2.63

14264 30/5 MFD 370V RND N 3.13

14266 35/5 MFD 370V RND N 3.88

14178 40/5 MFD 370V RND N 3.88

14268 40/7.5 MFD 370V RND N 3.88

14269 45/5 MFD 370V RND P 3.88

14249 45/7.5 MFD 370V RND N 3.88

14191 50/5 MFD 370V RND N 3.88

14192 50/7.5 MFD 370V RND P 3.13

14239 50/10 MFD 370V RND P 3.88

14193 55/5MFD 370V RND N 4.75

14194 55/7.5 MFD 370V RND N 4.75

14195 60/5 MFD 370V RND P 3.88

14196 60/7.5 MFD 370V RND N 4.75

14054 70/7.5 MFD 370V RND P 3.88

14290 50/5 MFD 440/370V RND P 14291 50/7.5 MFD 440/370V RND P 14124 50/10 MFD 440/370V RND P 14299 55/10 MFD 440/370V RND P 14292 55/5 MFD 440/370V RND P 14293 55/7.5 MFD 440/370V RND P 14294 60/5 MFD 440/370V RND P 14295 60/7.5 MFD 440/370V RND P 14296 60/10 MFD 440/370V RND P 14358 65/5 MFD 440/370V RND P 14359 65/7.5 MFD 440/370V RND P 14162 65/10 MFD 440/370V RND P 14255 70/5 MFD 440/370V RND P 14166 70/7.5 MFD 440/370V RND P 14169 70/10 MFD 440/370V RND P 14257 80/5 MFD 440/370V RND P 14216 80/7.5 MFD 440/370V RND P 14117 80/10 MFD 440/370V RND P

3.88 3.88 3.88 3.88 3.88 3.88 3.88 3.88 3.88 3.875 3.875 4.75 4.75 4.75 4.75 4.88 4.75 4.75

14197 80/5 MFD 370V RND P 3.88

14198 80/7.5 MFD 370V RND P 3.88

14201 80/10 MFD 370V RND P 3.88

Capacitor Base Dimensions

Base Dimension on page C-7

C­8

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com

COMPONENTS

MARS Mini-Split Run Capacitors

MARS mini-split motor run capacitors are epoxy/resin sealed and widely used as the start-up and/or run capacitor for your motor. They feature very small dissipation factor and inherent temperature rise, high insulation resistance, and stable capacitance.
Specifications:
· Ambient temperature: 70° C · Rated voltage: 450 VA · Capacitance tolerance: ±5 · 50/60 Hz · Standard: IEC252-2001

MARS NO.
12380 12381 12382 12383 12384 12385 12386 12388 12390

DESCRIPTION
1 MFD X 450V 1.5 MFD X 450V 2 MFD X 450V 2.5 MFD X 450V 3 MFD X 450V 3.5 MFD X 450V 4 MFD X 450V 5 MFD X 450V 6 MFD X 450V

DIMENSIONS H D W
1-1/2 X 1/2 X 1 1-1/2 X 1/2 X 1 1-1/2 X 1/2 X 1 1-1/2 X 3/4 X 1-1/4 1-1/2 X 3/4 X 1-1/4 1-7/8 X 3/4 X 1-3/8 1-7/8 X 3/4 X 1-3/8 1-7/8 X 7/8 X 1-3/8 1-7/8 X 1 X 1-1/2

Motor Run Capacitors

QC-6 Kit

93001

For conversion of screw-type connections
on relays

Resistor for Start Capacitors

93007

2 watt (15,000 ohm) Resistors, 10/Pk

QC-13 for Start Capacitors

93106

10 pc 2 watt (15,000 ohm) resistors with .25-in female spade
connectors, 10/Pk

Snap-on Mounting Brackets for Motor Start Capacitors

93026 93027 93028

2.75 in 3.38 in 4.38 in
Sold in 10 pack

Case Dimensions*
CASE SIZE 1 2 4 5 6 7 8

DIAMETER 1.44 1.44 1.81 1.81 2.06 2.06 2.56

LENGTH 2.75 3.38 3.38 4.38 3.38 4.38 4.38

*Capacitors may be put in different case sizes ocassionally, but will not be larger than those stated.

Accessories For Relays & Capacitors

Protector (boots) for Motor Run Capacitors

93011

1 Hole Boot, 25/Pk

93012

2 Hole Boot, 25/Pk

Wrap-Around Brackets for Motor Run Capacitors

93014

Oval 1.94 x 2.78 for base A, 10/Pk

93015

Oval 1.97 x 2.94 for base C, 10/Pk

93116

Oval 2.25 x 3.66 for base D, 10/Pk

Mounting Brackets for Round Capacitors

93031SnaFpor-1o.6n3 iMn aondu1n.7t5iinn gdiamBrackets for Motor Start Capacitors

93032

For 2.0 in diam

93033

For 2.50 in diam

Sold in 5 pack

Bakelite End Caps for Motor Start Capacitors

93018 93019 93020 93021
93022 93023 93024 93025

BEC-1 1.44 in BEC-2 1.81 in BEC-3 2.06 in BEC-4 2.56 in Sold in 10 pack
For mounting OFF MOTOR. Leads on top side.
TEC-1 1.44 in TEC-2 1.81 in TEC-3 2.06 in TEC-4 2.56 in Sold in 10 pack

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

C­9

COMPONENTS

Motor Run Capacitors

Single Section Run Capacitors

370 VOLT

MFD

OVAL MARS NO.

ROUND MARS NO.

OVAL ROUND JARD NO. JARD NO.

2

12002 12092 12902 12992

3

12003 12093 12903 12993

4

12004 12094 12904 12994

5

12005 12095 12905 12995

6

12006 12096 12906 12996

7.5 12007 12097 12907 12997

10

12008 12098 12908 12998

12.5 12009 12099 12909 12999

15

12010 12210 12910 12710

16

12211

12911

17.5 12012 12212 12912 12712

20

12014 12214 12914 12714

25

12015 12215 12915 12715

30

12017 12217 12917 12717

35

12018 12218 12918 12718

40

12021 12221 12921 12721

45

12023 12223 12923 12723

50

12025 12225 12925 12725

55

12024 12226 12924 12726

60

12087 12227 12987 12727

65

12011 12128 12988 12828

70

12089 12229 12989 12729

80

12090 12199 12990 12899

100

12116

12916

440/370 VOLT

MFD

OVAL MARS NO.

ROUND MARS NO.

OVAL ROUND JARD NO. JARD NO.

2

12026 12102 12926 12802

2.5 12019

12919

3

12027 12103 12927 12803

4

12028 12104 12928 12804

5

12029 12105 12929 12805

6

12030 12106 12930 12806

7.5 12031 12107 12931 12807

10

12032 12232 12932 12732

12.5 12033 12233 12933 12733

15

12034 12234 12934 12734

17.5 12036 12236 12936 12736

20

12037 12237 12937 12737

25

12040 12240 12940 12740

30

12041 12241 12941 12741

35

12043 12243 12943 12743

40

12045 12245 12945 12745

45

12048 12248 12948 12748

50

12049 12251 12949 12751

55

12050 12252 12950 12752

60

12051 12254 12951 12754

65

12052 12357 12952 12657

70

12130 12258 12830 12758

75

12135

12831

80

12140 12259 12840 12759

90

12068

12868

C­10

Dual Section Run Run Capacitors

370 VOLT

MFD

OVAL MARS NO.

ROUND MARS NO.

OVAL ROUND JARD NO. JARD NO.

15/3 15/4 15/5 15/10 17.5/4 17.5/5 20/3 20/4 20/5 20/7.5 20/10 20/15 25/3 25/4 25/5 25/7.5 25/8 25/10 25/15 30/3 30/4 30/5 30/7.5 30/10 30/15 35/3 35/4 35/5 35/7.5 35/10 40/3 40/4 40/5 40/7.5 40/10 45/3 45/4 45/5 45/7.5 45/10 45/15 50/3 50/5 50/7.5 50/10 55/5 55/7.5 55/10 60/3 60/5 60/7.5 60/10 65/5 70/5 70/7.5 70/10 75/5 75/7.5 75/10 80/5 80/7.5 80/10 80/12.5 85/5 85/7.5 85/10

12141 12056 12057 12058 12059 12060 12061 12062 12063
12064 12164 12142 12065 12066 12143 12131 12167 12133 12144 12145 12069 12146 12147
12148 12071 12072 12149 12150 12151 12158 12171 12152 12134 12173
12174 12153 12136 12137
12138
12154 12155
12139 12156 12157 12159
12163 12123

12121 12122 12203 12204 12205 12206
12207 12260 12016 12208 12209 12242 12175 12261 12262
12213
12244 12263 12264 12224 12228 12039 12082 12231 12266 12235 12238 12074 12267 12178 12268 12246 12073 12247 12269 12249 12250
12075 12191 12192 12239 12193 12194 12067 12076 12195 12196 12265 12042 12053 12054 12055 12044 12046 12084 12197 12198 12201 12202 12129 12230 12222

12841 12956 12957 12958 12959 12960 12961 12962 12963
12864 12964 12842 12965 12966 12843 12832 12867 12833 12844 12845 12969 12846 12847
12848 12971 12972 12849 12850 12851 12858 12871 12852 12834
12874 12853 12836 12837
12838
12854 12855
12839 12856 12857 12859
12863 12817

12701 12702 12703 12704 12705 12706
12707 12760 12716 12708 12709 12711 12875 12761 12762
12713
12720 12763 12764 12724 12728 12939 12730 12731 12766 12735 12738 12739 12767 12878 12768 12746 12747 12947 12769 12749 12750
12753 12755 12825 12757 12893 12894 12967 12976 12895 12896 12865 12742 12953 12954 12955 12744 12946 12984 12897 12819 12824 12722 12829 12756 12922

Dual Section Run Run Capacitors

440/370 VOLT

MFD
10/5 15/4 15/5 15/10 17.5/5 20/5 20/7.5 20/10 20/15 25/3 25/4 25/5 25/7.5 25/10 25/15 30/3 30/4 30/5 30/7.5 30/10 35/3 35/4 35/5 35/6 35/7.5 35/8.5 35/10 40/3 40/4 40/5 40/6 40/7.5 40/10 45/3 45/4 45/5 45/6 45/7.5 45/10 50/5 50/7.5 50/10 50/12.5 55/5 55/7.5 55/10 60/3 60/5 60/7.5 60/10 60/12.5 65/5 65/7.5 65/10 70/5 70/7.5 70/10 75/5 75/7.5 75/10 80/5 80/7.5 80/10 85/5 85/7.5 85/10

OVAL MARS NO.
12165 12270 12271 12177 12180
12083
12184 12182 12183 12186 12181 12187 12038 12035 12085 12179 12185 12188 12176 12272 12080 12086 12189 12273
12190 12274 12108 12013
12275 12276 12109 12110
12101
12297 12298

ROUND MARS NO.
12111
12118 12356 12350 12115 12354 12351 12112 12353 12355 12278 12279 12113 12114 12126 12120 12281 12282 12352 12077 12070 12283 12119 12284
12091 12078 12285 12286 12220 12287 12088 12079 12219 12288 12127 12289 12172 12290 12291 12124 12253 12292 12293 12299 12160 12294 12295 12296 12161 12358 12359 12162 12255 12166 12169 12168 12125 12047 12257 12216 12117 12022 12020 12001

OVAL ROUND JARD NO. JARD NO.

12765 12770 12771 12777
12880
12983
12884 12882 12883 12886
12881 12887 12982 12835 12985 12879 12885

12811
12818 12656 12650 12780 12654 12651 12812 12653 12655 12778 12779 12813 12814 12826 12820 12781 12782 12652 12977 12870 12783

12888 12876 12772 12877 12986 12889 12773
12890 12774 12808 12913
12775 12822 12809 12776
12810
12815 12898

12784
12797 12978 12785 12786 12920 12787 12798 12979 12891 12788 12827 12789 12872 12790 12791 12892 12719 12792 12793 12799 12860 12794 12795 12796 12861 12642 12659 12862 12823 12866 12869 12968 12901 12935 12801 12816 12821 12938 12942 12944

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com

COMPONENTS

MARS 780 Definite Purpose Contactors

MARS 780 Definite Purpose Contactors

MARS 780 - 1 pole with shunt contactors are designed for demanding applications. The enclosed body design provides quiet operation and improved durability by reducing the intrusion of dust and dirt. Silver-cadmium oxide contacts provide increased contact life when switching inductive loads.

61720

Features:

· Enclosed body and coil ­ standard cover

· Push to test button

61320

· Quad quick connects

· Box lugs - large window arch design

· Screw terminals and or box lugs available on 30 amp

· Coils - class F insulation

· UL File E96705

1 Pole with Shunt 30 - 40 Amps

MARS NO.

FURNAS NO.

61320 61321 61322 61323

45EG10AJA, 45CG10AJA, 45DG10AJA 45EG10AFA, 45CG10AFA, 45DG10AFA 45EG10AGA, 45CG10AGA, 45DG10AGA 45EG10ALA, 45CG10ALA, 45DG10ALA

FLA

LOCKED

NON

ROTOR AMPS INDUCTIVE

240V 277V AMPS

COIL VOLTS

TERMINATION

24

30 180 180

120

40

Screw Type

208-240

277

61720 45EG10AJAL

24

61721 45EG10AFAL

120

MARS 780 Definite Purpose Contactors

MARS 780 - 2 pole contactors are designed for demanding applications. The enclosed body design provides quiet operation and improved durability by reducing the intrusion of dust and dirt. Silver-cadmium oxide contacts provide increased contact life when switching inductive loads.

61345

Features:

· Enclosed body and coil ­ standard cover

· Push to test button

61755

· Quad quick connects

· Box lugs - large window arch design

· Screw terminals and or box lugs available on 30 amp

· Coils - class F insulation

· UL File E96705

2 Pole 30 - 40 Amps

MARS NO.

FURNAS NO.

FLA

LOCKED ROTOR AMPS
240V 480V 600V

NON INDUCTIVE
AMPS

COIL VOLTS

61345 61346 61347 61348 61349

45EG20AJ, 45CG20AJ, 45DG20AJ
45EG20AF, 45CG20AF, 45DG20AF
45EG20AG, 45CG20AG, 45DG20AG
45EG20AL, 45CG20AL, 45DG20AL
45EG20AH, 45CG20AH, 45DG20AH

30 180 150 120

24 120 40 208-240 277 480

TERMINATION Screw Type

61745 45EG20AJL

24

61722 45EG10AGAL 30 180 180

61723 45EG10ALAL

61724 45EG10AHAL

61730 61731 61732 61733 61734

45GG10AJAL, 45FG10AJA, 45GG10AJA 45GG10AFAL, 45FG10AFA, 45GG10AFA 45GG10AGAL, 45FG10AGA, 45GG10AGA 45GG10ALAL, 45FG10ALA, 45GG10ALA 45GG10AHAL, 45FG10AHA, 45GG10AHA

40 240 240

40

208-240 Box Lug

277

480

24

120

50

208-240 Box Lug

277

480

61746 45EG20AFL

120

61747 45EG20AGL 30 180 150 120

40 208-240

Box Lug

61748 45EG20ALL

277

61749 45EG20AHL
45GG20AJL, 61755 45FG20AJ,
45GG20AJ
45GG20AFL, 61756 45FG20AF,
45GG20AF
45GG20AGL, 61757 45FG20AG, 40 240 200 160
45GG20AG
45GG20ALL, 61758 45FG20AL,
45GG20AL
45GG20AHL, 61759 45FG20AH,
45GG20AH

480 24 120 50 208-240 277 480

Box Lug

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

C­11

COMPONENTS

MARS 780 Definite Purpose Contactors
MARS 780 Definite Purpose Contactors
MARS 780 - 2 pole "Large Body" contactors feature a 2 pole configuration in a 3 pole body for increased durability in demanding applications.
Features: · Large arch window box lugs · Recessed push to test button · Accepts MARS 780 and Furnas auxiliary switches · Use standard MARS 780 replacement coils · Dual QC coil terminals plus screw terminal for easy termination and
jumper arrangements · Coils - class F insulation · UL File E96705

61425

61440

2 Pole - Large Body 30 - 40 Amp

MARS NO.

FURNAS NO.

LOCKED ROTOR AMPS

FLA

240V

480V

600V

NON INDUCTIVE AMPS

COIL VOLTS

61425

42BF15AJ, 42AF15AJ

24

61426

42BF15AF, 42AF15AF

120

30

180

150

120

40

61427

42BF15AG, 42AF15AG

208-240

61428

42BF15AL, 42AF15AL

277

61440

42CF15AJ

24

61441 61442

42CF15AF 42CF15AG

120

40

240

200

160

50

208-240

61443

42CF15AL

277

HORSEPOWER

1 PH

3 PH

240V

240V

3 HP

7.5 HP

5 HP

10 HP

TERMINATION Box Lug Box Lug

C­12

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com

COMPONENTS

MARS 780 Definite Purpose Contactors

MARS 780 - 3 Pole Contactors

MARS 780 - 3 pole contactors are designed for demanding applications. The enclosed body design provides quiet operation and improved durability by reducing the intrusion of dust and dirt. Side attachment rails for auxiliary switches (30-60 amp contactors) allow attachment of MARS 780 or Furnas auxiliary switches. Silver-cadmium oxide contacts provide increased contact life when switching inductive loads.

Features: · Large arch window box lugs · SEMS screws or box lugs available on 30 amp contactors · Recessed push to test button (not on 75 and 90 amp contactors) · Enclosed body design · Accepts MARS 780 and Furnas auxiliary switches · Use standard MARS 780 replacement coils · Dual QC coil terminals plus screw terminal for easy termination and
jumper arrangements · Coils - class F insulation · 600 volt rating · Foot print compatible · UL File E96705

61445

61480

3 Pole 30 - 90 Amp

MARS NO.
61430* 61431* 61432* 61433* 61434* 61750 61751 61752 61753 61754 61445 61446 61447 61448 61449 61460 61461 61462 61463 61464 61470 61471 61472 61473 61474 61480 61481 61482 61483 61484 61490 61491 61492 61493 61494

FURNAS NO.
42BF35AJ 42BF35AF 42BF35AG 42BF35AL 42BF35AH
42CF35AJ 42CF35AF 42CF35AG 42CF35AL 42CF35AH 42DF35AJ 42DF35AF 42DF35AG 42DF35AL 42DF35AH 42EF35AJ 42EF35AF 42EF35AG 42EF35AL 42EF35AH 42FE35AJ106 42FE35AF106 42FE35AG106 42FE35AL106 42FE35AH106 42GE35AJ106 42GE35AF106 42GE35AG106 42GE35AL106 42GE35AH106

* For 25 Amp Contactors - Use 30 Amp in Place of 25Amp

FLA

LOCKED ROTOR AMPS

240V

480V

600V

NON INDUCTIVE
AMPS

COIL VOLTS

1 PH 240V

24

120

30

180

150

120

40

208-240

3 HP

277

480

24

120

30

180

150

120

40

208-240

3 HP

277

480

24

120

40

240

200

160

50

208-240

5 HP

277

480

24

120

50

300

250

200

63

208-240

5 HP

277

480

24

120

60

360

300

240

75

208-240

7.5 HP

277

480

24

120

75

450

375

300

94

208-240

15 HP

277

480

24

120

90

540

450

360

120

208-240

15 HP

277

480

HORSEPOWER

3 PH

240V

480V

7.5 HP

10 HP

7.5 HP

10 HP

10 HP

15 HP

15 HP

20 HP

20 HP

25 HP

25 HP

40 HP

30 HP

50 HP

TERMINATION 600V

15 HP

Screw Type

15 HP

Box Lug

20 HP

Box Lug

25 HP

Box Lug

30 HP

Box Lug

40 HP

Box Lug

50 HP

Box Lug

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

C­13

COMPONENTS

MARS 780 Definite Purpose Contactors
30-40A 1 Pole with Shunt
30-40A 2 Pole
30-40A 2* Pole & 3 Pole

Note - 2* Pole is a 3 pole body with center contacts removed.

MARS NO.

FLA

POLES

A

B

C

D

D1

E

MTG SCREW G MAX WIRE SIZE

61320-61323

30

1

3.19

1.97

2.46

1.5

1.77

1.61

10

8

61720-61724 61730-61734

30-40

1

3.19

1.97

2.46

1.5

1.77

1.61

10

4

61345-61349

30

2

3.19

1.97

2.46

1.5

1.77

1.61

10

8

61745-61749 61755-61759

30-40

2

3.19

1.97

2.46

1.5

1.77

1.61

10

4

61430-61434

30

3

3.69

2.38

2.87

3.13

3.25

1.98

10

8

61750-61754 61445-61449

30-40

3

3.69

2.38

2.87

3.13

3.25

1.98

10

4

61425-61428 61440-61443

30-40

2(at 3P)*

3.69

2.38

2.87

3.13

3.25

1.98

10

4

C­14

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com

COMPONENTS

MARS 780 Definite Purpose Contactors
50-60A 3 Pole

75-90A 3 Pole

MARS NO.
61460-61464 61470-61474
61480-61484 61490-61494

FLA

POLES

A

B

C

D

D1

E

MTG SCREW G MAX WIRE SIZE

50-60

3

4.04

2.87

3.11

3.13

3.25

2.24

10

2

75-90

3

5.02

3.5

4.39

4.43

4.63

2.87

10

1/10

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

C­15

COMPONENTS

MARS 780 Definite Purpose Contactors
Renewal Parts and Accessories
· Snap on side mounted auxiliary switches · Replacement coils

61614

61616

61623

61625

61679

61692

61684

Auxiliary Switches

MARS NO.

FURNAS NO.

DESCRIPTION

CONTACTOR F.L.A.

61610

49ACRO

1 NO

61611

49ACRC

1 NC

61612

49ACR6

1 NO- 1 NC

61613

49ACR7

2 NO

30 - 60

61614

49ACR8

2 NC

61615

49D36098001

SPDT

61616

49D36098003

DPDT

61623

-

SPDT

61624

-

1 NO

75-90

61625

-

1 NC

USED ON
61320-61324 61720-61724 61730-61734 61345-61349 61745-61749 61755-61759 61430-61434 61750-61754 61445-61449 61425-61428 61440-61443 61460-61464 61470-61474
61480-61484 61490-61494

MARS 780 Contactor Coil Characteristics

Contactor Series

Inrush VA Sealed VA Sealed Watts

1 Pole with shunt 30 to 40 amp

40

7.5

2.5 - 3.5

2 Pole - Small Body 30- 40 Amp

45

8

2.5 - 4.0

2 Pole Large Body 30- 40 Amp

90

16

3.5 - 5.0

3 Pole 30 - 40 Amp

90

16

3.5 - 5.0

3 Pole 50 - 60 Amp

145

20

5.0- 7.0

3 Pole 75 - 90 Amp

235

32

10.0 - 12.0

MARS 780 Replacement Coils

MARS NO.

FURNAS NO.

CONTACTOR SIZE

61679

-

61680

-

61681

-

3 Pole 30-40 Amp

61682

-

61683

-

61684

-

61685

-

61687

-

3 Pole 50-60 Amp

61690

-

61691

-

61692

-

61693

-

61694

-

3 Pole 75-90 Amp

61695

-

61696

-

C­16

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

COIL VOLTAGE
24V 120V 208-240V 277V 480V 24V 120V 208-240V 277V 480V 24V 120V 208-240V 277V 480V
®
marsdelivers.com

COMPONENTS

Furnas NEMA Contactors & Starters

Furnas NEMA Contactors & Starters

Application:
NEMA heavy duty contactors and starters are designed for across the line starting of 3 phase motors. Typical applications include cooling towers, refrigeration equipment, and commercial HVAC. NEMA contactors provide the switching (on/off) function. NEMA starters consist of a NEMA contactor with the addition of motor protection via a solid state overload relay which includes phase loss protection.

T p

()

100.0 10.0

958A Trip Curve with Tolerance
min nom max

1.0

Standard NEMA Contactor Features:
· Rugged industrial design epoxy encapsulated coil seals out moisture, promotes heat transfer, and resists electrical, mechanical, and thermal stresses. The 45 degree wedge action contacts reduce tracking and provide faster arc quenching. The resulting selfcleaning and reduced contact bounce mean cooler operation and longer life for the large silver cadmium oxide contacts
· Dual Voltage Coils 120/240 VAC is standard 24 VAC and 240/480 VAC are available as accessories
· Easy coil access. Top mounted coil requires no tools to change
Standard NEMA Starter Features:
· NEMA Contactor
· True phase loss protection Trips within 3 seconds and is self protected from short circuits
· High accuracy +/- 2% repeat trip accuracy
· Self powered requires no hard wiring or separate power source
· Heaterless construction minimizes energy costs. Does not require the use of complicated heater charts. Simply set the dial on the overload relay to the motor F.L.A.
· Overload trip class 20

61770

61811

0.1 100%

200%

300%

400%

500%

Current, % of dial setting

600%

700%

800%

NEMA Starters

MARS NO.

SEIMENS NO.

61770 14CUC32BA

61771 14CUD32BA

61772 14DUC32BA

61774 14DUD32BA

61775 14DUE32AA

61776 14DUE32BA

61777 14ESG32BA

61779 14FUF32AA

61780 14FUF32BA

61782 14HUG32BA

61783 14HUG32AA

NEMA SIZE
0 0 1 1 1 1 1-3/4 2 2 3 3

AMP RATING
18 18 27 27 27 27 27 45 45 90 90

HORSEPOWER

200V

230V

460V

2

2

5

3

3

-

2

2

5

3

3

10

7-1/2

7-1/2

-

7-1/2

7-1/2

-

10

10

15

-

-

15

10

15

25

25

30

50

25

30

50

OVERLOAD COIL RANGE VOLTAGE

ENCL.

2.5-10A 120/240 NEMA 1

9-18A

120/240 NEMA 1

2.5-10A 120/240 NEMA 1

9-18A 120/240 NEMA 1

13-27A 120/240 Not Included

13-27A 120/240 NEMA 1

10-40A 120/240 NEMA 1

13-52 A 120/240 Not Included

22-45A 120/240 NEMA 1

45-90A 120/240 NEMA 1

45-90A 120/240 Not Included

NEMA Contactors

MARS NO.

SEIMENS NO.

61811 40DP32AA

61813 40FP32AA

NEMA SIZE
1
2

AMP RATING
27
45

200V 7-1/2 10

HORSEPOWER 230V
7-1/2
15

460V 10 25

COIL VOLTAGE
120/240
120/240

ENCL.
Not Included Not Included

Parts & Accessories for Starters & Contactors

MARS NO.

SEIMENS NO.

DESCRIPTION

NEMA SIZE

61652

75D73070J

Coil 24VAC

0-2.5

61650

75D73070A

Coil 120/240V

0-2.5

61653

75D73070C

Coil 240/480V

0-2.5

61654

75D73070D

Coil 208V

0-2.5

61656

75CF14

Replacement Contact Kits*

0

61657

75DF14

Replacement Contact Kits*

1

61658

75FP14

Replacement Contact Kits*

2

61659

49AB10

N.O. Auxiliary Contact

0-3

61660

49AB01

N.C. Auxiliary Contact

0-3

* Replacement contacts are sold in kits that will re-build 1 power pole. For example: Use (3) 75CF14 contact kits to re-build a 3 pole device.

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

C­17

COMPONENTS

GE Definite Purpose Contactors
Model 453 Definite Purpose Contactors
The compact models feature universal mount bases, taped coils, and combination phillips/ slot head screws. The GE compact design features "no burn" coil design. This self-protecting coil meets the Trane specification. 453 GE compact design contactor meets ARI 780. Some other manufacturer's economy model compact contactors do not meet this rigorous spec.
Features: · Compact overall size · Combo phillips/slothead screws/hexhead on 30 amp · Universal mount base

Specifications: CR453C Compact, 30A, 40A, 1-Pole Plus Shunted Pole & 2-Pole

FULL LOAD AMPS

RESISTIVE AMPS PER POLE

LOCKED ROTOR AMPS

SINGLE PHASE, 50/60 HZ

240/277V

480V

600V

30

40

180

150

120

* Ratings shown are for 1-phase, 2-pole.

MARS NO.

FLA

13101

30

RESISTIVE RATING
PER POLE
40

POLES 1-1/2

VOLTAGE 24

GE MODEL 453CC3HAAAM

HEIGHT 2-9/16

13101

POLES 1 + Shunt

DIM. WIDTH
2

DEPTH 3-1/4

Universal Enclosure
Universal Contactor Enclosure
The MARS 92680 Universal Contactor enclosure will fit contactors from 20 to 40 amp. This enclosure will also fit the new smaller frame ACC533 and ACC633 contactors. Each enclosure comes with all the necessary mounting screws.

MARS NO. 92680

MFG. PART NO. AHK425A

DESCRIPTION Universal Contactor Enclosure

C­18

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com

COMPONENTS

MARS Definite Purpose Contactors

MARS Definte Purpose Contactors

MARS definite purpose contactors are designed for use on refrigeration, air conditioning, and electric heating systems. They are available in one pole with shunt (one and one half pole) configurations, from 30 thru 40 amps. MARS brand definite purpose contactors are also available in 2 pole models (30 and 40 amp) and 3 pole models (30 through 75 amp). The universal mounting base allows replacement of most contactor brands. Straight-thru wiring and small size speeds installation.

Features:

· Used in air conditioning, heating and refrigeration

· Box lug terminations speed installation · Universal mounting base

· Contact cover and enclosed coils reduce dirt and insect intrusion
· Compact design · Silver-Cadmium contacts
Specifications: · Meets ARI 780/790 requirements · cULus Approval

Auxiliary Switches

MARS NO

DESCRIPTION

61623 61624 61625

SPDT 1 NO 1 NC

· 1,000,000 Cycle mechanical life

USED ON
All 3 Pole 910

91311-13

91631-33, 91731-33

MARS NO. FLA

91311

91312

30

91313

91315

91316

30

91317

91321

91322

30

91323

91325

91326

30

91327

91331

91332

30

91333

91335

91336

30

91337

91411

40

91421

91422

40

91423

91431

91432

40

91433

91531

91532

50

91533

91631

91632

60

91633

91731

91732

75

91733

POLES 1 Pole w/Shunt 1 Pole w/Shunt
2 2 3 3 1 Pole w/Shunt 2 3 3 3 3

LOCKED ROTOR AMPS 240 277 480 600

RES. AMPS

180 180

40

180 180

40

180

-

150 120

40

180

-

150 120

40

180

-

150 120

40

180

-

150 120

40

240 240

-

-

50

240

-

200 160

50

240

-

200 160

50

300

-

250 200

63

360

-

300 240

75

450

-

375 300

94

COIL VOLTS
24 120 208/230 24 120 208/230 24 120 208/230 24 120 208/230 24 120 208/230 24 120 208/230 24 24 120 208/230 24 120 208/230 24 120 208/230 24 120 208/230 24 120 208/230

TERMINATION Screw Type Box Lug Screw Type Box Lug Screw Type Box Lug Box Lug Box Lug Box Lug Box Lug Box Lug Box Lug

1 PH 240
3 HP 3 HP 5 HP 5 HP 7.5 HP 15 HP

HORSEPOWER

3 PH

240

480

-

-

-

-

-

-

-

-

7.5 HP

10 HP

7.5 HP -

10 HP -

10HP

15 HP

15 HP

20 HP

20 HP

25 HP

25 HP

40 HP

600 -
15 HP 15 HP
20 HP 25 HP 30 HP 40 HP

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

C­19

COMPONENTS

Magnetic Line Contactors
30 Amp Two Pole Contactors
The MARS Series 180 contactors are designed primarily to replace contactors used in air conditioning and electric heating to control blower motors. In addition they are used to switch pumps and computer power supplies. Replace General Electric Contactors and other manufacturers including WR, Essex/RBM and Honeywell.
Features: · Replace all 3ARR8, 9, 27, and 28 General Electric contactors · Replace WR, Essex/RBM and Honeywell · Instructions and cross reference chart included · Non-positional · UL and CSA listings available

18001

Cross Reference

GEMLINE

HONEYWELL NO.

MC11

R850B1146

MARS REPLACEMENT
18001

COIL schematic

KIT 93103 Sold Seperately
4 SCREWS & 4 TERMINALS

MARS NO.
18001
93103

DESCRIPTION
30 Amp 2 Pole Magnetic Line Contactor
Push-On Terminals Adapters and Screws.

FULL LOAD AMPS

RESISTIVE AMPS

30

30

LOCKED ROTOR AMPS
120

-

-

-

COIL VOLTAGE
24
-

POLES 2 -

COIL VOLT
24
-

PICK-UP HOT
20.5
-

MAX COLD
19.2
-

Fan Centers

MARS Relay/Transformer Fan Control Centers

Schematic: MARS series 240

fan centers provide

Black Common

Black Common

Purple Common Black Common

White

Black Common

White

Purple Common
Black Common

Black Common White 120V
Red 208V Orange 240V

convenient low

voltage control of

one and two speed

fan motors and

Coil

Coil

Coil

Yellow NC Red NO

Yellow NC Red Yellow NO
Brown NC Red NO

auxiliary circuits in

heating, cooling, or

heating/cooling

applications. Each

MARS fan center is

a reliable, compact unit consisting of a

24010

24012

24013

24 volt control transformer and a plug-in switching relay mounted on a 4" square electrical junction box cover.

All line voltage connections are made inside the box with color coded pre-stripped leads. Low voltage

connections are made at a convenient terminal board mounted to the transformer.

Brown NC Red NO

24010

Features: · Choice of SPDT, SPNO / SPNC or
DPDT relay switching options · UL 1585 40VA transformer · Color coded leads · Low voltage terminal board · Mounts directly to 4" electrical box · 50/60 Hertz

40VA 3/4 HP

MARS NO.
24010 24012 24013

TRANSFORMER

PRIMARY

SECONDARY

VOLTAGE CONNECTIONS VOLTAGE CONNECTIONS

120/208/ Color coded 240 leads, pre-stripped

24V

Terminal board with 5 screw terminals

120

Color coded leads, pre-stripped

24V

Terminal board with 5 screw terminals

120

Color coded leads, pre-stripped

24V

Terminal board with 5 screw terminals

RELAY
DPDT SPNO/ SPNC SPDT

CONTACT RATINGS

120V AC (AMPS)

240V AC (AMPS)

FULL LOCKED FULL

LOCKED

LOAD ROTOR LOAD

ROTOR

13.8

82.8

6.9

41.4

13.8

82.8

6.9

41.4

13.8

82.8

6.9

41.4

C­20

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com

COMPONENTS

Transformers

MARS Control Transformers NEMA Class II Open Construction

MARS compact open construction transformers are less than 2-1/4" in height. This makes them ideal as replacements within existing equipment.

MARS control transformers are available with various outputs and voltages for special applications.

50351

Application:
Provide power source for control circuit for air conditioning, heating, or refrigeration systems.

Features: · UL class 2 recognized · Low heat rise · Primary color coded leads · Secondary color coded leads,
or 1/4" male quick connects · Foot-mount

50354 50364

Foot-Mount Open Construction

MARS NO.

VA RATING

HZ

PRIMARY

SECONDARY

VOLTAGE CONNECTIONS VOLTAGE CONNECTIONS

50351

20 50/60

120

Color coded leads

24

Color coded leads

50352

40 50/60

120

Color coded leads

24

Color coded leads

50353

40 50/60 208/240

Color coded leads

24

Color coded leads

50354

40

50/60 120/208/240

Color coded leads

24

Color coded leads

50355*

40

60

120

Color coded leads

12/24

Color coded leads

50350

20

50/60 120/208/240

Color coded leads

24

Color coded leads

50357

40 50/60

277

Color coded leads

24

Color coded leads

50359(1)

40

50/60 120/208/240

Color coded leads

24/12/2.5

Color coded leads

50308

50

50/60 120/208/240

Color coded leads

24

Color coded leads

* Not UL listed (1) In line fuse protection

Foot-Mount Open Construction With Primary & Secondary Quick Connects

MARS NO.
50362 50364 50363

VA RATING
40 40 40

HZ
50/60 50/60 50/60

PRIMARY

SECONDARY

VOLTAGE 120
120/208/240 208/240

CONNECTIONS
1/4" Male quick connects
1/4" Male quick connects
1/4" Male quick connects

VOLTAGE 24 24 24

CONNECTIONS
1/4" Male quick connects
1/4" Male quick connects
1/4" Male quick connects

MARS Control Transformers NEMA Class II End Bell Type
MARS end bell transformers provide enclosures for the primary and secondary windings, MARS multi-mount models offer three mounting options - Foot, Plate, or Conduit mount.
MARS control transformers are available with various outputs and voltages for special applications.

Application: Provide power source for control circuit for air conditioning, heating, or refrigeration systems.
Features: · UL class 2 recognized · Low heat rise · Primary color coded leads · Secondary color coded leads,
or screw terminals · Multi-mount or plate-mount

50306 50305

50302 50303 50304
50301

50337

Foot-Mount End Bell Type

MARS NO.
50301

VA RATING

HZ

20

60

PRIMARY

VOLTAGE 120

CONNECTIONS
Color coded leads

SECONDARY

VOLTAGE CONNECTIONS

24

Color coded leads

Multi-Mount End Bell Type

MARS NO.

VA RATING

HZ

PRIMARY

SECONDARY

VOLTAGE CONNECTIONS VOLTAGE CONNECTIONS

50302 50303 50304 50306* 50314 50333* 50337

40 50/60

120

Color coded leads

24

Screw terminals

40 50/60 208/240

Color coded leads

24

Screw terminals

40

60

120/208/240

Color coded leads

24

Screw terminals

48

60

277

Color coded leads

24

Color coded leads

50

50/60 120/208/240

Color coded leads

24

Color coded leads

48

50/60 120/208/240

Color coded leads

24/12/2.5

Color coded leads

75

50/60 120/208/240

Color coded leads

24

Color coded leads

* Not UL listed (1) Color coded leads on secondary, (2) Screw terminals on secondary

Plate-Mount End Bell Type

MARS NO.

VA RATING

HZ

PRIMARY

SECONDARY

VOLTAGE CONNECTIONS VOLTAGE CONNECTIONS

50305

40 50/60

120

Color coded leads

24

Screw terminals

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

C­21

COMPONENTS

Transformers

MARS Control Transformers NEMA Class II
Hub-Mounted Transformers with Circuit Breakers and Multiple Inputs of 120/208/240/480 VAC

Available either in 50VA or 75VA, these 2 versatile transformers replace Honeywell® AT150F and AT175F. All leads pass through the chase nipple.
· MARS 50319, 50VA, MARS 50372, 75VA
· 3 Way mounting · Four inputs including
120/208/240/480 VAC · UL Recognized

50319 50372

Hub Mount End Bell Type

MARS VA NO. RATING

HZ

50319 50 50/60

50372 75 50/60

PRIMARY

VOLTAGE 120/208/240/480 120/208/240/480

CONNECTIONS
Color coded leads
Color coded leads

SECONDARY

VOLTAGE 24 24

CONNECTIONS
Color coded leads
Color coded leads

MARS Control Transformers NEMA Class II Heavy Duty End Bell Type

MARS control transformers are available with various outputs and voltages for special applications.
Application: MARS heavy duty end bell transformers offer a wide variety of higher VA rated models. These models are the choice when extra power is the solution.
Features: · UL class 2 recognized · 50/60 Hz · Low heat rise · Color coded leads · Foot-mount

50316

50340

Foot-Mount End Bell Type

MARS NO.

VA RATING

HZ

PRIMARY

SECONDARY

VOLTAGE CONNECTIONS VOLTAGE CONNECTIONS

50316

60 50/60 208/240

Color coded leads

24

Color coded leads

50320(1)

75

50/60

120/208/ 240/480

Color coded leads

24

Color coded leads

50324

75 50/60 208/240

Color coded leads

24

Color coded leads

50326

75 50/60

480

Color coded leads

24

Color coded leads

50340*

100

50/60

120/208/ 240/480

Color coded leads

24

Color coded leads

*100 VA does not qualify for NEMA Class II (1) Inline fuse

Foot Mounted Open Construction

MARS NO.

VA RATING

HZ

50339(2) 75 50/60

PRIMARY

SECONDARY

VOLTAGE 480

CONNECTIONS VOLTAGE CONNECTIONS

Color coded leads

120 Color coded leads

(2) UL 506

C­22

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com

COMPONENTS

Transformers

MARS Control Transformers NEMA Class II Manual Reset Style
MARS control transformers are available with various outputs and voltages for special applications.
Application: Provide power source for control circuit for air conditioning, heating, or refrigeration systems.
Features: · UL class 2 recognized · Low heat rise · Color coded leads or quick
connect terminals · Foot-mount

50321 50327 50341 50375

Foot-Mount End Bell Type with Manual Reset

MARS NO.

VA RATING

HZ

50327

50

60

50321

75 50/60

50375

75 50/60

50341* 100 50/60

50312

60 50/60

50370

75 50/60

50371

100 50/60

PRIMARY

SECONDARY

VOLTAGE
120/208/ 240/480
120/208/ 240/480
120/208/ 240/575
120/208/ 240/480
120/208/ 240/480
120/277/ 380/575
120/208/ 277/575

CONNECTIONS
Color coded leads
Color coded leads
Color coded leads
Color coded leads
Color coded leads
Color coded leads
Color coded leads

VOLTAGE 24 24 24 24 24 24 24

CONNECTIONS
Color coded leads
Color coded leads
Color coded leads
Color coded leads
Color coded leads
Color coded leads
Color coded leads

* 100VA and higher does not qualify for NEMA Class II

MARS Power Transformers

Application:
Provide 120V power source for air conditioning, heating, or refrigeration systems. MARS power transformers provide dual purpose options -- 120V or 24V secondary with 208V/240V/480V primary connections. Three VA selections offer a true powerhouse!
Features: · Color coded leads · Compact size · Low heat rise

50380

Power Transformers Foot-Mount Open Construction

MARS NO.

VA RATING

HZ

PRIMARY VOLTAGE CONNECTIONS

SECONDARY VOLTAGE CONNECTIONS

50380(1) 50 50381(2) 100

60 208/240/480 60 208/240/480

Color coded leads Color coded leads

120/24 120/24

Color coded leads Color coded leads

(1) Not UL listed (2) UL 506

GE Type Ip Core and Coil Transformers

GE type IP transformers are core and coil units designed for industrial control, panel board, HVAC and general purpose applications. They conform to ANSI C89.2, and are UL listed and CSA certified. These transformers are lightweight, small and designed for minimum mounting dimensions.
Features: · 60 Hz
· Encapsulated thru 500VA
· Control power applications
· UL listed, UL-506 File E2739
· CSA certified, C22.2 Number 66, File 3272
· 50 Hz available on special order basis

50502
top view front view Encapsulated Style Views

Encapsulated

MARS NO.

CONT. KVA

PRIMARY

SECONDARY

A

DIMENSIONS

B

C

D

E

50502 .075 240/480 120/240

4.22 3.29 2.79 2.41

2.50

50504 .150 240/480 120/240

4.67 4.04 3.29 2.66

3.12

50506 .250 240/480 120/240

5.17 4.04 3.29 3.16

3.12

50507 .300 240/480 120/240

5.17 4.04 3.29 3.16

3.12

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

C­23

COMPONENTS

JARD Transformers

Hub-Mounted Transformers with Circuit Breakers and Multiple Inputs of 120/208/240/480 VAC

Available either in 50VA or 75 VA, these 2 versatile transformers replace Honeywell® AT150F and AT175F. All leads pass through the chase nipple.
· Model 5041MCB, 50 VA, Model 7541MCB, 75 VA
· Plate mount or foot mount
· Four inputs including 120/208/240/480 VAC
· UL Recognized

44519 44520

Fully Enclosed Junction Box Ready
· Several models with dual voltage output
· Welded laminations for quiet operation
· Conservative heat rise characteristics
· UL 506
44532 44534

44527

44540

MARS NO.
44519
44520

JARD NO.
5041MCB
7541MCB

VA

PRIMARY VAC

SECONDARY VAC

50

120/208/240/480

24

75

120/208/240/480

24

Multi-Mount Transformers Closed Construction, 4" x 4" Plate
· Optional 3-way mounting for maximum flexibility · Safety agency approved · Welded laminations for quiet operation

MARS NO.

JARD NO.

VA

PRIMARY VAC

SECONDARY VAC

44522

4011M

40

120

24

44524

4031M

40

120/208/240

24

44525

5031M

50

120/208/240

24

44526

5032M

48

120/208/240

2.5/12/24

44527

7541M

75

120/208/240/480

24

44528

7541STM

75

120/240/277/575

24

MARS NO. 44532
44533
44534
44535

JARD NO.

VA

5048PC

50

5048STPC

50

10048PC

100

10048STPC

100

PRIMARY VAC
240/480
208/277/575
240/480
208/277/575

SECONDARY VAC 120 120 120 120

Open Construction Foot Mount Wire Leads

MARS NO.

JARD NO.

VA

PRIMARY VAC

SECONDARY VAC

44536

5024P

50

208/240

120/24

44538

7524P

75

208/240

120/24

C­24

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com

COMPONENTS

JARD Foot Mount Transformers

44518

44504

44513

44517

JARD # 4031VM Includes 2 Brackets

Open Construction, Wire Leads

· Safety agency approved

MARS NO.
44501 44502 44503 44504 44505 44507 44508 44509 44510

JARD NO.
2031F 4011F 4021F 4031F 4032F 40271F 5031F 5032F 7531F

VA

PRIMARY VAC

20

120/208/240

40

120

40

208/240

40

120/208/240

40

120/208/240

40

277

50

120/208/240

50

120/208/240

75

120/208/240

SECONDARY VAC
24 24 24 24 2.5/12/24 24 24 2.5/12/24 24

Closed Construction With Circuit Breaker
· All models feature a UL recognized manual reset circuit breaker · Safety agency approved

MARS NO.
44511 44512 44513 44514 44515 (1)

JARD NO.
5041C 6041C 7541C 7541STC 10041C

VA

PRIMARY VAC

SECONDARY VAC

50

120/208/240/480

24

60

120/208/240/480

24

75

120/208/240/480

24

75

120/277/380/575

24

100

120/208/240/480

24

(1) Not UL, UL506

Closed Construction Quick Connect

MARS NO.
44517

JARD NO.

VA

4031OEM

40

PRIMARY VAC
120/208/240

SECONDARY VAC 24

Versatile 3-Way Mounting

MARS NO.

JARD NO.

VA

PRIMARY VAC

44518

4031VM

40

120/208/240

SECONDARY VAC 24

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

C­25

COMPONENTS

MARS Surge Protection Device

MARS Side Open Disconnect Boxes with Internal Surge

MARS Disconnect with integrated surge protector provides a unitized design for quick and clean installation. The metal weatherresistant enclosure provides additional robustness and security. MARS Surge Protectors provide the performance necessary to protect critical components in high efficiency mini-split and unitary HVAC equipment.

Features:

Specifications Disconnect:

· Side open disconnect · Integrated internal surge protector · Thermally Protected MOV's

· Single phase 240V · 10,000 Amp rating · NEMA 3R enclosure

· Metal-weather resistant enclosure · External - Green & Red LED
Status Indicators · cULus rating

· Weather proof enclosure
· Available in fused and non-fused

· 3 Year Warranty

· $7,500 Connected Equipment Warranty

Surge Protector Ratings: · 120/240V Single (Split)
Phase 50/60Hz · Short Circuit Current Rating
o 22,000 Amps · MCOV L-N 150V / L-L 330V · Voltage Protection Rating
o L-N 800V / L-L 1200V · UL 1449 4th Edition · Type 1 or 2 Surge
Protection Rating

Protects: · Compressors · Heat Pumps · Ideal for
Ductless System · Inverter Boards · ECM Motors · Control Boards · Transformers · Relays · Sensors

MARS NO. 83915 83916 83917
MARS NO. 83914

DESCRIPTION
60 Amp Non-Fused 30 Amp Fused 60 Amp Fused

VOLTAGE
120/240 120/240V 120/240V

WIRE CONFIGURATION
L1,L2,L/N-G
L1,L2,L/N-G
L1,L2,L/N-G

SPD TYPE 1 or 2
1 or 2
1 or 2

MCOV
150/300 150/300 150/300

ENCLOSURE
NEMA 3R, Rainproof NEMA 3R, Rainproof NEMA 3R, Rainproof

UL 1449 4TH EDITION
cULus
cULus
cULus

DESCRIPTION Replacement Surge Module

83914

83915

MARS HVAC Surge Protective Device

The MARS SPD is designed to protect your HVAC equipment from power spikes, surges and transients. Power spikes and surges can damage compressors, control boards, sensors and ECM motors resulting in costly repairs and down time. The MARS SPD utilizes Thermally Protected MOV technology to provide safe and reliable surge protection.

120/240 VAC Single Split Phase SPD for use on a variety of HVAC Equipment

Protects:

· Compressors · ECM Motors

· Heat Pumps

· Control Boards

· Ideal for

· Transformers

Ductless Systems · Relays

· Inverter Boards · Sensors

Features:

LED Protection Status Indicators
Meets all UL 1449 4th Edition Standards

· Easy Installation to Disconnect

· Weatherproof 4X Enclosure

· 18" Pre-stripped Leads · Green & Red LED Status Indicators · Thermally Protected MOVs

18 in. 10 Gauge Leads

· 120/240V Single (Split) Phase 50/60Hz

· Short Circuit Current Rating o 22,000 Amps

· MCOV L-N 150V / L-L 330V · Voltage Protection Rating
o L-N 800V / L-L 1200V · UL 1449 4th Edition · Type 1 or 2 Surge Protection Rating · 3 Year Warranty · $7,500 Connected
Equipment Warranty

1/2 inch x 20 Threaded Nipple (weatherproof and UV resistant)

Unmatched Surge Protection Ratings
Type 4x Weatherproof Enclosure

MARS Surge Protective devices utilize Thermally Protective MOV surge technology

MARS NO.
83905

VOLTAGE

WIRE CONFIGURATION

120/240 L1,L2,L/N-G

SPD TYPE
1 or 2

MCOV

ENCLOSURE

UL 1449 4TH EDITION

150/300 Type 4X

cULus

MARS HVAC Surge Protective Device

The MARS 83904 SPD is designed specifically for 120V furnace and air handler applications. The furnace and air handler contain components that must be protected from surges such as, ECM motors, Control Boards, Transformers. The MARS Surge utilizes thermally protected MOV technology for safe and reliable protection of equipment. The 120V Surge Device is easy to install with only 2 wires to connect.
Protects: · Ideal for 120V Ductless Systems · Furnace & Air Handlers · Inverter Boards · ECM Motors · Control Boards · Transformers · Relays · Sensors
Features: · Easy 2 Wire Installation · 10" Pre-stripped Leads · Green LED Status Indicator · Thermally Protected MOVs · 120V Single Phase 50/60Hz · Short Circuit Current Rating
o 10,000 Amps · MCOV L-N 150V · Voltage Protection Rating
o L-N 700V · UL 1449 4th Edition · Type 1 or 2 Surge Protection Rating · 3 Year Warranty · $7,500 Connected Equipment
Warranty

120 VAC Single Split Phase SPD
LED Protection Status Indicator Meets all UL 1449 4th Edition Standards

Unmatched Surge
Protection Ratings
8 in. 12 Gauge
Leads

1/2 inch x 20 Threaded Nipple (weatherproof and UV resistant)

MARS Surge Protective devices utilize Thermally Protective MOV surge technology

MARS NO.
83904

VOLTAGE

WIRE CONFIGURATION

120

L1,L2,L/N-G

SPD TYPE
1 or 2

MCOV

ENCLOSURE

UL 1449 4TH EDITION

150

Type 2

cULus

C­26

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com

COMPONENTS

MARS Surge Protection Device & Condensate Pumps

MARS HVAC Surge Protective Device

The iSPD (Intelligent Surge Protection Device) offers comprehensive protection for your HVAC equipment.

The MARS 83907 Surge Protection Device is designed to provide maximum compressor protection from harmful power surges, transients and over-voltages utilizing the latest Thermally Protected MOV technology.

In addition, the modules microprocessor technology monitors line voltage to protect the compressor from starting or running during "brown outs" and low line voltage. The module also monitors refrigerant temperatures to identify coil freeze-up and or low refrigerant issues.
If the module detects a low voltage or refrigerant issue the compressor is shut down. The module will automatically reset when specified operating parameters are restored and determined to be stable.
In the event of diminished surge protection or failure, the compressor will not be allowed to start until the module is replaced.

Protects the Following Equipment and Components:

· Compressors

· Control & Defrost Boards

· Heat Pumps

· Reversing Valves

· Sensors & Relays · ECM Motors

· Transformers

Plus: · Low Voltage Protection · Coil Freeze-up / Low Refrigerant Detection · Short Cycle Guard

Features: · Easy installation to disconnect box · Weatherproof 4X enclosure · Fits 1/2" knockouts · Green & Red LED status indicators · Thermally protected MOV's · 240V single phase 50/60Hz · Max surge current 10,000 A · Max continuous over voltage
° L-N 150V / L-L 300V · Voltage protection rating
° L-N 700V / L-L 1000V · 3 Year warranty · $7,500 Connected equipment warranty

MARS NO.
83907

VOLTAGE 240

WIRE CONFIGURATION
L1,L2,L/N-G

SPD TYPE
1 or 2

MCOV 150/300

ENCLOSURE Type 4X

UL 1449 4TH EDITION
cULus

240 VAC Single Split Phase

SPD for use on a variety

of HVAC Equipment

Microprocessor

Based Controls

18 in. 10 Gauge Leads

LED Status Indicators
Meets all UL 1449 4th Edition Standards

1/2 inch x 20 Threaded Nipple
Unmatched Surge Protection Ratings Type 4x Weatherproof Enclosure UV Resistant
MARS Surge Protective devices utilize Thermally Protective MOV surge technology

MERCURY Mini-Split Pump Kit
Mercury pumps are designed for wall mount ductless mini-split AC units and evaporator coil applications. Pump mounting is flexible and can be installed in the evaporator unit, duct channel or above the unit in the ceiling.

Kit Includes ­ Pump, reservoir with safety switch, adapter, cable ties, tubing to connect pump and reservoir, velcro mounting tape for ease of installation and service.
Features: · Self priming, fully potted pump · Silent operation · 26 Ft lift · 2.6 Gallon per hour condensate capacity · Standard safety switch provides connections for unit shut down and alarm. · For use with equipment up to 25,000 BTU's

MARS NO.
21791

VOLTAGE 115/220V 60Hz

HEAD GPH

0 FT.

13 FT.

20 FT.

26 FT.

2.64

2.38

1.59

0.92

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

C­27

COMPONENTS

Condensate Pumps

MARS Condensate Pump - 24' Lift

MARS Low Profile 22' Pump

MARS new line of medium condensate pumps are designed to out-perform the competition while providing quiet operation and reliability.

The MARS pump design couples industry leading performance with the installation flexibility and features you need to get the job done.

The quick release silicone check

valve allows for quick and efficient servicing without the need to

21780

remove the condensate line.

The integrated safety switch can

be wired for equipment shut down or directly to a high level alarm.

Features: · 24 foot lift

RELAY Y GWR

· 125 gph

· 0.5 gal reservoir

· Patent pending, quick release check valve

· Field serviceable "duck bill" check valve · Rubber isolation feet

TWO BLUE LEAD

WIRES

Y GWR

· Drip proof housing design

THERMOSTAT

· Solid float

· Integrated safety switch 250 volt and float switches

· ABS and stainless steel construction

MARS NO. 21780 21781 21782 21783

DESCRIPTION
115 V, 60 Hz, 0.91 Amps, 71 Watts 6' Cord, 3/8" Check Valve, Safety Switch Medium Reservoir
115 V, 60 Hz, 0.91 Amps, 71 Watts 6' Cord, 3/8" Check Valve, Safety Switch 20' Tubing, Medium Reservoir
230 V, 60 Hz, 0.6 Amps, 75 Watts 6' Cord, 3/8" Check Valve, Safety Switch Medium Reservoir
230 V, 60 Hz, 0.6 Amps, 75 Watts 6' Cord, 3/8" Check Valve, Safety Switch 20' Tubing, Medium Reservoir

Gallons Per Hour Pump Performance Comparison Chart

FOOT LIFT

1

5

10

15

20

24

MARS

125

98

74

70

43

7

Comp. 1

84

75

60

42

10

0

Comp. 2

117

98

70

58

11

0

Comp. 3

105

95

73

36

0

0

Specifications: Performance-Gallons Per Hour @ Height In Feet

MODEL NO.

1

5

10

15

20

24

21780

125

98

74

70

43

7

21781

125

98

74

70

43

7

21782

139

119

70

50

28

7

21783

139

119

70

50

28

7

Check Valve Replacement

MARS NO.

DESCRIPTION

21787 Check Valve Replacement Kit

21787

Features:
· Low profile pump · Compact design · Integrated safety switch · Quick service check valve · Drip proof housing · Class leading performance

21784

MARS NO. 21784 21785

DESCRIPTION
115 V, 60 Hz, 1.07 Amps, 67 Watts, Low Profile, 22' Lift 6' Cord, 3/8" Check Valve, Safety Switch Medium Reservoir
230 V, 60 Hz, 0.53 Amps, 68 Watts, Low Profile, 22' Lift 6' Cord, 3/8" Check Valve, Safety Switch Medium Reservoir

MARS 16' Pump
Features:
· 16' lift pump · Whisper quiet · 1/2 gal reservoir · Rubber isolation feet · Quick service check valve · Class leading performance

21786

MARS NO. 21786

DESCRIPTION
115 V, 60 Hz, 0.75 Amps, 49 Watts, 16' Lift 6' Cord, 3/8" Check Valve, Safety Switch Medium Reservoir

MODEL NO. 21780 21781 21782 21783 21784 21785 21786

LENGTH 10.25 10.25 10.25 10.25 10.25 10.25 10.25

DIMENSIONS WIDTH 5.125 5.125 5.125 5.125 5.04 5.04 5.125

HEIGHT 6.375 6.375 6.375 6.375 5.28 5.28 6.375

Condensate Pump vs. Competition

FEATURE

MARS COMP. 1

24 ft. Lift

l

Motor Corrosion Protection

l

Drip Proof Motor Housing

l

l

Drip Proof Motor & Switches

l

Vibration Absorbing Rubber Feet

l

l

Side Mount

l

l

Quick Release Check Valve

l

l

Internal Safety Switch

l

Solid Float

l

l

COMP. 2
l l l

COMP. 3 l l l

C­28

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com

COMPONENTS

MARS Start Assists

MARS AllStartTM Hard Start Device

The MARS AllStartTM is a two wire hard start device designed to provide maximum starting torque for single phase PSC and CSIR compressors up through 10HP. The MARS AllStartTM recycles instantly for maximum convenience on troublesome hard start jobs.

Independent testing has

determined that the MARS

AllStartTM provides more starting torque than other competitive

32708

models, and this results in quicker

starts. Test results on a range of

head pressures from 166 to 300 PSI indicate that the MARS AllStartTM

started the test compressor in an average of 21.7% less time than the

leading competitor! More available starting torque means less time to

get problem compressors started.

MARS offers the largest assortment of refrigeration and air conditioning compressor starting components. When the proper starting relay and capacitor combination is a must, they are available from MARS. When getting a problem compressor started in the field "NOW" is the job, rely on the new MARS AllStart.TM

Features: · Maximum starting torque! · More than 20% faster starts! · Easy two wire installation

STARTING TIME COMPARISON (least is best)

350 300

MARS ALLSTART
LEADING COMPETITOR

250

· Recycles instantly

200

· Individually packaged with wiring instructions

166 205 225 250 275 300 Head Pressure In PSI

SUPPLIER KICKSTART

PART NO.

MARS REPLACEMENT

TO5

32708

SUPCO

SPP8

32708

WATSCO

WSX-1

32708

Time In Milliseconds COMPRESSOR LEADS
WHITE BLACK
RED

MARS Combination Starters

The MCS is a combination start relay, start capacitor, and motor overload. It is designed to replace those components on a 115 volt single phase refrigeration compressor installed on a capillary tube system.
The MCS is factory wired and comes with a connection diagram on the product label for maximum convenience.

Features: · Maximum starting torque! · More than 20% faster starts! · Easy two wire installation · Recycles instantly · Individually packaged with
wiring instructions

SUPPLIER GEMLINE ROBERTSHAW SUPCO

PART NO.
HS 410 HS 810
600-410 600-810
RCO 410 RCO 810

MARS REPLACEMENT
32741 32781
32741 32781
32741 32781

32741

COMMON

START

RUN

BLACK POWER BLACK

MARS NO. 32741 32781

MODEL NO. MCS 41 MCS 81

H.P. 1/4 TO 1/3 1/12 to 1/5

VOLT MAX. 115V 115V

MARS NO. 32708

MODEL NO. AllStart

H.P. 1/2 to 10

VOLT MAX. 115-277V

MARS Motor Torque Multiplier

The MARS MTX 100, MTX 200 and MTX 300 motor torque multipliers feature a combination PTC solid state device, and start capacitor in one compact unit.
The MTX 100 is designed for use on PSC motors and compressors up to 5HP, 277V maximum; the MTX 200 is designed for use on PSC motors and compressors up to 10HP, 277V maximum; and the MARS MTX 300 is designed for use on PSC motors & compressors from 1-1/2 up to 10HP, 115-230V. These units are easily installed by connecting the two leads from the MTX unit to the motor run capacitor terminals.

Features: · Totally solid state integrated design · Fast, easy two wire installation · Three mounting options; clip, screw, or
capacitor bracket · Individually packaged

SUPPLIER PART NO.

GEMLINE ROBERTSHAW
SUPCO

HS 600 HS 650
600-052 600-057
SPP5 SPP6

MARS REPLACEMENT
32701 32702
32701 32702
32701 32702

32701

MARS NO. 32701 32702

MODEL NO. 100 200

H.P. 1/2 to 5 1/2 to 10

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

32702
VOLT MAX. 277V 277V
C­29

COMPONENTS

MARS Start Assists
MARS 3 Wire Hard Start Kits
MARS 3 Wire Hard Start Kits provide the additional starting torque required for quicker compressor starts in systems using higher pressure refrigerants. Improved starting performance extends compressor life and minimizes potential refrigerant contamination due to overheated compressor windings. MARS Hard Start Kits also improve system life and performance by reducing undue overload stress on contactors and run capacitors. If your system is slow to start, MARS has a Hard Start Kit to fit your application.
Features: · Start relay made in the USA
and approved by all compressor manufacturers. · Start capacitor made in Mexico · 30% faster starts · 3 wire design ensures proper "drop-out" · Extends life of compressor · Kit contains mounting hardware

MARS 2 Wire Hard Start Kits
MARS 2 Wire Hard Start Kits provide quick and easy installation on the job-site with only 2 connections. 2 Wire Hard Starts provide the additional starting torque for quicker compressor starts and improves compressor. MARS Hard Start kits also improve system life and performance by reducing undue overload stress on contactors and run capacitors.
If your system is slow to start, MARS has a Hard Start Kit to fit your application.
Features:
· Start relay made in the USA and approved by all compressor manufacturers.
· NGM Start Capacitor is approved by all major HVAC manufacturers
· 30% faster starts
· Extends life of compressor
· 2 wire design speeds installation
· Kit contains mounting hardware

Cross Reference

MARS NO.

5-2-1 (CPS)

32715 32716 32717

CSR U1 CSR U2 CSR U3

MARS NO. 32715
32716
32717

VOLTS
208-230/240 208-230/240 208-230/240

Supco
3W1 3W2 3W3

Packard (2 wire)
TQS1 TQS2
­

Diversitech (2 wire)
HSK5 HSK1
­

DESCRIPTION
3 Wire Hard Start 1 to 3 Ton 3 Wire Hard Start 3.5 to 5 Ton 3 Wire Hard Start 4 to 5 Ton

Cross Reference MARS NO. 32713 32714

KickStart TO-5 KS-1

MARS NO. 32713
32714

VOLTS
208-230/240 208-230/240

Packard (2 wire) TQS1 TQS2

Diversitech (2 wire) HSK5 HSK1

DESCRIPTION
2 Wire Hard Start 1 to 3 Ton 2 Wire Hard Start 3.5 to 5 Ton

C­30

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com

COMPONENTS

MARS General Purpose Switching Relays

For Motor Starting Circuits up to One Horsepower

Features:
· Replace Potter & Brumfield PR series, Deltrol, Guardian, Magnacraft, etc.
· Plastic enclosed coil minimizes damage, resists dirt and moisture
· 5/16" diameter silver contacts for long life
· Tough phenolic base
· Reinforced screw terminals
· UL and CSA listings available

DPST-NO

DPDT with auxiliary

MARS NO.

P & B SERIES

CONTACTS ARRANGEMENT

AMP

COIL COIL RES. VOLTAGE IN OHMS

NOM. POWER

43008 PRD7AY0

DPST-NO

25

120

290

9.8VA

43014 PRD11AY0

DPDT

25

120

290

9.8VA

Cross Reference Information

POTTER & BRUMFIELD

MARS NO.

PR7AY0-120V

43008

PR11AY0-120V

43014

DETROL NO. 20240-83D 20241-83D

MARS NO. 43008 43014

Replacement Relay for Fan Control Centers
Provides quick and easy plug-in installation to restore like new operation without replacing the entire fan center. The universal relay will cover all MARS fan centers and many competitive brands.

90340

MARS NO.
90340

USED ON 24010, 24012, 24013

DESCRIPTION DPDT universal plug-in replacement relay

2-Pole Air Conditioning Relays

The MARS Series 903 switching relays are intended for many applications in air conditioning, refrigeration, and heating. Other uses include general purpose switching in appliances, fan controls, and vending machines. Our relays are available in 24, 110/120, and 208/240 coil voltages with various combinations of power and pilot duty contacts.

90340

Features: · Replaces Honeywell and White-Rodgers/RBM - cross reference on
package · Double quick-connect terminals on coil · 2.13 x 1.88 x 2.25 in. · Base is designed for easy replacement of competitive relays · Molded terminal numbers and circuit diagram on top of relay · UL and CSA listings available

Full Load Amps Resistive Amps* Locked Rotor Amps
Horsepower *277 VAC

POWER 120V 208/240V
12 6
15 15
60 35
3/4 3/4

PILOT 120V 208/240V
- -
3 3
- -
1/10 1/10

1

3

2

4

6

5

MARS NO.
90340 90341 90342
90343 90344 90345
90346 90348

COIL VOLTAGE
24 110/120 208/240
24 110/120 208/240
24 208/240

TERMINALS 1-2-3 Power
Power
Pilot

Cross Reference Information

WR/RBM NO.

MARS REPLACEMENT

90-340

90340

90-341

90341

90-342

90342

90-343

90343

90-344

90344

90-345

90345

90-346

90346

90-348

90348

HONEYWELL NO.
R4222B1082 R4222B1090 R4222D1013 R4222D1021 R4222N1010 R4222V1002 R4222V1010 R8222B1067 R4222D1014 R8222N1011 R8222V1003

TERMINALS 4-5-6
Power
Pilot
Pilot
MARS REPLACEMENT
90344 90345 90341 90342 90348 90344 90345 90343 90340 90346 90343

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

C­31

COMPONENTS

MARS General Purpose Switching Relays

SPST and SPDT Fan Relays
The MARS Series 903 relays are among the most popular relays used in air conditioning today. They will replace the WR/Essex/RBM Type 84 (90-290 thru 90-295) quick-connect and screw terminal versions. Features: · 0.25 inch quick-connect
terminals · Packaged with instructions and
cross reference · Replace 90-290 thru 90-295
and 90-290Q thru 90-295Q · Dimensions: 2.38 x 1.63 x 1.50 in. · Tab bracket, Non-positional · UL and CSA listings available

COIL VOLTAGE
24 110/120 208/240

MARS NO. SPST
90290 90291 90292

MARS NO. SPDT
90293 90294 90295

Contact Rating-- All Models/Amps

VOLTAGE

FULL LOAD

LOCKED ROTOR

RESISTIVE

120

12

60

18

240

8

48

18

277

7

42

18

Coil Data: 24-240 VAC @ 50/60 Hz; 5 VA Max. Inrush; 3.0 VA Max. Sealed

Cross Reference Information

WR/RBM MARS WR/RBM

NO.

NO.

NO.

MARS NO.

90-290 90290 90-293 90293

90-290Q 90290 90-293Q 90293

90-291 90291 90-294 90294

90-291Q 90291 90-294Q 90294

90-292 90292 90-295 90295

90-292Q 90292 90-295Q 90295

Heavy Duty Fan Relays
MARS Heavy Duty Fan Relays are used on heating and air conditioning equipment to provide switching of heavier loads with a compact size relay. MARS Heavy Duty Fan Relays replace WR/Essex/RBM type 184.
Features: · 0.25 inch quick-connect
terminals · Packaged with instructions
and cross reference · Replaces WR/Essex/RBM
Type 184 · Tab bracket,
Non-positional · UL and CSA listings
available

Contact Rating-- All Models/Amps

Coil Data

VOLTAGE

FULL LOAD

LOCKED ROTOR

RESISTIVE

COIL VOLTAGE

120

12

60

18

240

8

48

18

277

7

42

18

24 120 208/240

MAX INRUSH
5 VA 5 VA 5 VA

MAX SEALED
3 VA 3 VA 3 VA

COIL MARS NO. MARS NO. MARS NO.

VOLTAGE SPST

SPDT SPNO-SPNC

24

90360

90370

90380

110/120 90362

90372

90382

208/240 90364

90374

90384

277

90377

Cross Reference
WR/RBM MARS WR/RBM MARS NO. NO. NO. NO.
90-360 90-360 90-374 90374 90-362 90-362 90-380 90380 90-364 90-364 90-382 90382 90-370 90-370 90-384 90384 90-372 90-372

C­32

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com

COMPONENTS

MARS Enclosed Switching Relays

MARS enclosed switching relays are heavy duty general purpose relays suitable for a variety of applications. They are commonly used in heating, air conditioning, vending machines, office machines, control panels and other general purpose applications. They are available in single pole, two pole and three pole models for either bracket or plug-in mounting. All MARS enclosed switching relays are protected by a tough polycarbonate cover to keep out dust and dirt. Blade type terminals fit standard plug-in mounts plus allow use with 3/16 inch quick-connect terminals or direct soldering.

43053

Features: · Simple connections · One, two and three pole
models · Plug-in or bracket mount · See-through protective cover · Three-way blade terminals,
plug-in, quick-connect or solder · UL and CSA listings available

Specifications: Dimensions: 2.0 X 1 1/2 X 1 3/8 Terminals: 3/16 blade Coil Data: 2.0 VA Contact Material: Silver alloy, gold flashed

43050
43058 93058

MARS COIL NO. VOLTAGE

43050

24

43053

24

43054 120

43056

24

43057 120

43058 240

43063

24

43064 120

43066

24

43067 120

43068 240

93058

HZ

AMP HORSEPOWER RATING 120V 240V

50/60 13

1/3

1/2

SWITCH ACTION
SPDT

50/60 13

1/3

1/2

DPDT

50/60 13

1/3

1/2

3PDT

50/60 13

1/3

1/2

DPDT

50/60 13

1/3

1/2

3PDT

Socket Base. Can be surface or DIN rail mounted.

TYPE MOUNT bracket bracket
bracket
plug-in plug-in

MARS Enclosed & Current Relays

MARS Current Relays - Universal Replacement
MARS current relays manufactured by General Electric can replace almost any current relay found on refrigerators, freezers, water cooler, pumps and vending machines.
Features: · Replace plug-on, bracket-
type, split-phase, and capacitor-start current relays · Covers replacement needs of 1/12 H.P. 115V to 1/8 H.P. 115V · Clearly labeled terminals for fast wiring · Each relay packaged with installation instructions and wiring diagrams · UL and CSA listings available

MARS GE NO. MAX

MIN APPLICATION SURVEY BY HORSEPOWER1

NO. 3ARR12 PAC PICK-UP DROP OUT

(AT 115)2

1/12 1/8 1/6 1/5 1/4 1/3 1/2 3/4

27001 309A

3.8

3.2

n n n n nnnn

27002 310A

5.2

4.4

n n n n nnnn

1. Current relays cannot be replaced by horsepower, amperage, or nameplate data alone. Refer to cross reference information for proper replacement of original equipment current relays by part numbers.
2. These current relays are often used on 230 volt applications, however this horsepower survey refers only to 115 volt applications.

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

C­33

COMPONENTS

MARS Relays & Potential Relays

For Submersible Pump Applications
The MARS 550 and 551 relays were specifically developed for submersible pump and other motor starting applications in high moisture environments. Because the control panels for these are often located in areas of high humidity, the components on them must resist the effects of moisture. Chrome plating on the core and armature and the relatively small area of contact eliminates armature sticking due to organic contaminants which was the number one cause of relay failure.
Features: · Used on F.E. Meyers, Franklin
Electric, Jacuzzi, Red Jacket, Sta-Rite, and Tait · 2 relays replace over 25 O.E.M. relays · Universal break-off bracket on each relay. Simply snap off parts not needed · UL and CSA listings available

19550

One-On-OneTM Direct Replacement Potential Relays

The relays are exact replacements for Bristol & Copeland applications. They conform to specifications and in most cases are the one-on-oneTM replacement relay used by the manufacturer
Other relays available on special order. Contact your local wholesaler or MARS Customer Service.

16028

BRISTOL 650058 650855
BRISTOL 650971
COPELAND 040-0001-00 040-0001-01 040-0001-04 040-0001-12 040-0001-17 040-0001-19 040-0001-20 040-0001-25 040-0001-26

MARS 16028 16051
MARS 16083
MARS 16086 16093 16085 16098 16095 16089 16023 16035 16022

COPELAND 040-0001-34 040-0001-35 040-0001-48 040-0001-50 040-0001-53 040-0001-54 040-0001-55 040-0001-59 040-0001-60 040-0001-61 040-0001-62

MARS 16099 16090 16093 16085 16095 16089 16023 16090 16091 16086 16035

COPELAND 040-0001-64 040-0001-68 040-0001-71 040-0001-74 040-0001-78 040-0001-79
COPELAND 040-0001-88 040-0001-89

MARS 16098 16099 16116 16122 16121 16152
MARS 16151 16155

MARS MARS CONTINUOUS NO. MODEL NO. COIL VOLTAGE

19550 MARS 550

130

19551 MARS 551

332

PICK-UP

MIN.

MAX

111

134

244

270

DROP-OUT

MIN.

MAX

15

40

40

90

MARS NO.
16104

G.E. NO. 3ARR3J3G3

USED BY Barnes [Burks, Decator] & Myers

MANUF.

OEM NO.
13178-A

GE MARS CAT. NO. NO.
3ARR3D7J4 19550

13179-A 3ARR3D3V4 19551

13180-A 3ARR3D3A4 19551 F.E. Myers
17891-A 3ARR3EA3A4 19551

17890-A 3ARR3EA3V4 19551

17889-A 3ARR3EA7J4 19550

155031-101 3ARR3J7J4 19550

Franklin Electric

155031-102 3ARR3J9V4 155031-104 3ARR3J2P3 155031-103 3ARR3J9U4

19551 19550 19551

155031-105 3ARR3J7M1 19550

MANUF

OEM NO.

GE CAT. NO.

23-1308-26 3ARR3EA9V5

23-1308-00 3ARR3EA7J5

23-1308-18 3ARR3EA7BB5 Jacuzzi
23-1308-34 3ARR3EA5U5

23-1308-42 3ARR3EA7M5

23-1308-49 3ARR3EA5C5

71-69 3ARR3EA7M5

Red Jacket

71-70

3ARR3EA5B5

71-47 3ARR3J3V2

U18-325 3ARR3J3V3

U18-665 Sta-Rite
U18-810

3ARR3J3A3 3ARR3J2P3

U18-811 3ARR3J5V3

A124P2 3ARR3EA5A5 Tait
A124P1 3ARR3EA7K5

MARS NO. 19551 19550 19550 19551 19550 19551 19550 19551 19551 19551 19551 19550 19551 19551 19550

Universal Replacement

Quick Reference Relay Selection Chart For General Electric Relays

1. Determine the General Electric model number of the Relay to be

replaced the "FORM" and "GROUP"

One number plus

1 or 2 Letters 1 or 2 Letters

EXAMPLE:

3ARR3*

A

3B

3

Basic Type

FORM

GROUP Non-Positional

Cross Reference Information

WR/RBM NO. 90-1 90-2 90-3 90-4 90-5 90-6 90-7 90-8 90-9 90-10 90-11 90-12
90-13 90-14 90-15 90-16 90-17 90-18 90-19 90-20 90-21 90-22 90-23 90-24

MARS NO. 19002 19009 19004 19003 19006 19006 19004 19003 19007 19008 19003 19007
19005 19003 19006 19007 19002 19008 19006 19007 19002 19003 19007 19008

WR/RBM NO. 90-25 90-26 90-27 90-40 90-41 90-63 90-64 90-65 90-66 90-67 90-68 90-69

MARS NO. 19006 19008 19005 19004 19008 19002 19003 19004 19005 19006 19007 19001

TECUM. NO. 82777 82778 82779 82781 82783 82784 82785 82787

MARS NO. 19002 19004 19008 19010 19003 19009 19006 19007

2.Locate in the following table the Relay GROUP and select the corresponding MARS Replacement Relay from the kit.
19002 MARS 63 replaces Relay GROUPS 2J; 2K; 2L; 2M; 5N; 7J; 7K; 7L: 7M; 7N; 8L; 8M; 8N
19003 MARS 64 replaces Relay GROUPS 3A; 3B; 3AV; 3AU; 4A; 4B; 6A; 6B; 6AV; 10A; 10B; 10AU; 10AV
19004 MARS 65 replaces Relay GROUPS 3P; 3R; 3AP; 5P; 5R; 5S; 5T; 22S
19005 MARS 66 replaces Relay GROUPS 3U; 3V; 3AT; 6U; 6V; 6W
19006 MARS 67 replaces Relay GROUPS 3C; 3D; 3AA; 4C; 4D; 4BK; 6C; 6D; 6AA; 10C; 10D; 26A; 26B; 26C; 26D
19007 MARS 68 replaces Relay GROUPS 3E; 3F; 3AB; 3AC; 4E; 4F; 4G; 6E; 6F; 6G; 10H; 10AB; 10AC; 26E; 26F; 26G; 26H; 27E; 27F; 27G
19008 MARS 69 replaces Relay GROUPS 3S; 3T; 10S; 10T; 25S; 25T; 10AS
19009 MARS 70 replaces Relay GROUPS 5B; 5C; 5D; 5AA; 8B; 8C; 8D
19010 MARS 71 replaces Relay GROUPS 6TV; 6TW; 10V
3. Install relay in accordance with instructions in MARS Replacement Kit

C­34

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com

COMPONENTS

MARS Potential Relays

MARS Universal Replacement

The MARS refrigeration potential relay service kit has become an industry standard since its introduction over fifty years ago. Its long-term reliability and easy replacement have been the key to its success. The wide calibration ranges and the universal bracket make the MARS potential relay service kit a must on every service truck.

19002 19001

Features:

· Genuine MARS relays replace thousands of O.E.M. models

· Non-positional

· Wide range of selectivity

· QC-6 Kit included with each relay to convert screw-on to push-on

· Instructions and wiring diagram included in each relay

· Universal break-off bracket on each relay. Simply snap-off parts not needed

93001

· The six most popular relays available in a service kit--19001 MARS 6 PAK--complete cross reference guide included in each kit

· UL and CSA listings available

MARS HVAC Potential Relays
MARS series relays are manufactured for the HVAC industry. These relays meet all requirements for original equipment relays.
Features: · 50/60 Hz · cULus · Contact rating 35 amp, 400
VAC · Operating position tab up · Instructions and wiring
diagram included in each relay · Class "B" insulation

19163 WIRING DIAGRAM

.12

.02

1.59 1.85

1.38

2.00

1.69

.08

Calibration Specifications

MARS NO.

MARS MODEL NO.

CONTINUOUS COIL VOLTAGE

19001 MARS 6 PAK

--

19002

MARS 63

170

19003

MARS 64

395

19004

MARS 65

332

19005

MARS 66

395

19006

MARS 67

420

19007

MARS 68

502

19008*

MARS 69

336

19009*

MARS 70

253

19010*

MARS 71

420

93001

QC-6

--

*Not included in 19001 MARS 6-Pak

PICK-UP

MIN.

MAX

--

--

139

153

260

275

168

182

215

225

295

315

325

345

180

195

285

305

212

232

--

--

DROP-OUT MAX
-- 55 120 90 120 125 135 105 77 121 --

Calibration Specifications

MARS NO.

MARS MODEL NO

CONTINUOUS COIL VOLTAGE

19163

MARS 163

168

19164

MARS 164

420

19165

MARS 165

332

19166

MARS 166

420

19167

MARS 167

420

19168

MARS 168

502

19169

MARS 169

332

19170

MARS 170

253

19171

MARS 171

420

Note: If used on 50 Hz, the PU will be about 13% lower

PICK-UP VOLTAGE
140-153 242-272 171-184 204-233 300-328 314-342 180-193 285-305 204-233

DROP-OUT VOLTAGE
20-45 60-121 40-90 60-121 60-121 60-135 40-90 35-77 60-121

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

C­35

COMPONENTS

Leak Detectors

MARS H-10 Pro Universal Refrigerant Leak Detector

The MARS H-10 Pro combines and enhances all the features of the previous H-10 Series models into one full featured unit. The H10 Pro Refrigerant Leak Detector continues to be the universal standard for checking halogenbased refrigerant leaks in residential and commercial applications. With automatic auto zero balance control it's unique sensor calibration system will pinpoint small, medium and large leaks. The instrument uses a tried-and-true positive ion emission heated diode with audible and visual leak rate indicators. It is the most sensitive and accurate leak detector to detect all CFC, HFC and HCFC refrigerants as low as 0.006 oz/yr, including R-410a and R-507. The unit is mounted in a durable carry case which houses the 4.5 foot probe with built in filter, carrying strap, wall adapter and operating instructions.
Features:
· All CFC, HFC and HCFC refrigerants, including but not limited to: R-12, R-22, R-134a, R-404A, R-410A, R-502, R-507, HFO-1233zd, HFO-1234yf and HFO-1234ze
· Improved sensor responsiveness with ultra-sensitive detection
· Dual power sources include rechargeable battery or external DC powered (wall adapter included)
· Selectable sensitivity to pinpoint small, medium or large leaks
· Unique visual sensor calibration system (with included reference leak bottle)
· Rugged enclosure with shoulder strap included
· Manual or automatic zero modes
· Headphone port allows for optional headset use in high-noise environments

Specifications: Nominal Leak Range: 0.006 oz/yr (stationary) | 0.1 oz/yr (moving probe per SAE J2791) Power Supply: 12 VDC - internal rechargeable sealed lead acid battery; 100-240 VAC wall adapter/universal battery charger to charge or run continuously Reference Leak: Approx. 0.006 oz/yr (stationary) | 0.1 oz/yr (moving probe per SAE J2791), 1 year life (typical) Ambient Operating Temp: 32°F to 104°F (0°C to 40°C) Battery Life: 3 hours (typically) Warm Up Time: Approx. 2 min. Response Time: 1 second Gases Detected: All CFC, HFC and HCFC non-flammable refrigerants Detection Principle: Positive Ion Emission Heated Diode Probe Length: 4.5 feet Dimensions: 10.5" L x 8.3" W x 5.4" H NOTE: sensors are consumed in normal operation. It is good practice to have a spare sensor available at all times.

MARS NO.
25301

CATALOG NO.
H-10 Pro

DESCRIPTION
Universal Refrigerant Leak Detector, Wall adapter or Battery Powered

Renewal Parts
MARS stocks genuine renewal parts for MARS, GE, and Bacharach H-10 Series Leak Detectors.

25315

25321

Renewal Parts For H-10 Professional, H-10N, H-10G, and H-10B

MARS CATALOG

NO.

NO.

25310 M1101UD

25315 H10N04 25314 M1101UU 25309 E7076DX 25325 M1101AH 25333 M1101VS

DESCRIPTION Maintenance kit (100 filters,
3 rubber probe tips) Plug-in sensor element Probe tip - clear plastic
Rubber tip for probe Battery charger - 120-240 VAC
Cigarette lighter adapter

H-10 PRO/PM

H-10N

H-10G

H-10B

3333

3333

3333

333 3 33

25323 M1101UC

Super tune up kit; sensor, leak vial, 100 filters
3 flow balls and 3 rubber probe tips

3333

25326 M1101AD 25321 K9344AH

Battery for H-10 Pro Reference Leak Assembly

3 3333

C­36

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com

COMPONENTS

MARS Solid State Motor Starting Devices & Solid State Timers

MARS Solid State Motor Starting Relay for Refrigerators and Freezers

MARS 32330 is a solid state PTC motor starting relay that mounts directly to any 3-pin fusite connector. One model replaces thousands of current relays used on 1/12 HP to 1/3 HP compressors.

Features: · Replaces Tecumseh Relays SSR2 and
SSR3 for push-on applications. · Non-positional · One model for 1/12 HP to 1/3 HP, 120 volt · UL and CSA listings available

MARS NO.
32330

HORSEPOWER 1/12 - 1/3

VOLTAGE 120

32330

MARS Solid State Timers Delay On Make

The MARS 32391 is the top-selling timer in the industry. Its reliability has been proven in the field by knowledgeable contractors.
The MARS 32391 will not be fooled by the thermostat anticipator.
Heavy duty MARS timers are offered for higher current applications.

32391

Features: · Easy two-wire installation · Proven reliability, all solid state · .25 in. quick connect terminals · Mounts in any position · Compact size · High accuracy · Totally enclosed and
encapsulated for proper heat dissipation

32394

Specifications:
· .040 amps min. latch current

MARS TYPE NO. DELAY

TIME DELAY RANGE

TYPE OF
ADJUSTMENT

INPUT VOLTAGE

HZ

MAX AMPS.

VOLTAGE DROP

CONN. DIA.

32391 on make 6 sec...8 min.

dial

19...240VAC 50/60 1

2.5 at 1 amp.

1

slide switch

32394

on make 1 sec..1023 sec.

adjustable in 1 second

19...144VAC

50/60

1

2.5 at 1 amp.

1

increments

Mars Solid State Timers Delay On Break

MARS solid state delay on break timers are designed to prevent short cycling of air conditioning, refrigeration and heat pump compressors. Upon application of power the load is energized. When the thermostat opens, or if there is a momentary loss of power, the load is de-energized and the delay period begins. The compressor will not start again during the delay period.

32392 32390

MARS number 32392 is a versatile

two wire timer that features

adjustable timing and can be used

with any voltage from 19 thru 240

VAC, 50 or 60 Hz. The MARS 32390 and the new

32505

32505 are the most simple and

economic ways to stop short

cycling on 24 VAC controlled

systems. Both devices are fixed 5 minute delay on break timers.

Features: · 1 to 3 second random re-start · Dial adjustable · Compact size · Mounts in any position · .25 in. quick connect terminals · Proven reliability · MARS delay-on-break timers are not load
sensitive

Adjustable
MARS TYPE NO. DELAY
32392 on break

TIME DELAY RANGE
6 sec...5 min.

TYPE OF
ADJUSTMENT

INPUT VOLTAGE

HZ

MAX AMPS.

VOLTAGE DROP

dial

19...240VAC 50/60 1

2.5 at 1 amp.

Fixed Delay
32390 on break 32505 on break

5 min. 5 min.

none

24 VAC 50/60 1

2.5 at 1 amp.

none

20-30 VAC 50/60 1

3 at 1 amp.

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

C­37

COMPONENTS

MARS Solid State Timers & Devices

Fan Time Delay Module

The MAHBC fan time delay module is a replacement for the direct motor control used by leading OEMs in high efficiency residential central air conditioning systems. The purpose of the control is to keep the blower motor running for 60 seconds after the thermostat has been satisfied. The result is an increase in residual cooling from the indoor coil without running the condensing unit, and thus, higher energy efficiency.
The MAHBC is ideal for retrofit where improved efficiency is desirable.

32574

Features:
· Wide ambient temperature operating range -40°F to 175°F
· 1/4" male quick connect terminals
· Easy surface mount with four #6 screws
· UL and CSA recognized

Cross Reference

OEM

PART NO.

BARD

8201-056

RHEEM

42-22515-01

SNYDER GENERAL

0001395336

MARS NO.
32574

MARS MODEL
MAHBC

VOLTAGE 24VAC

OUTPUT

120V

240V

1 HP

2 HP

TIME DELAY
60 SEC.

ACTION SPDT

MARS Bypass Timer
MARS 32395 is an adjustable, multi-voltage bypass timer that allows the temporary bypass of a control or device during startup. At the end of the delay period the control is returned to the circuit. Eliminate nuisance trips!

32395

Compressor Anti-Short Cycle Timer with Low Voltage Brownout Protection

Delay on break.
OEM replacement timers for Lennox, Rheem, Ruud, Trane, Heil Quaker, Keep Rite, Mc Quay, Snyder General and others.

Features:
· Lockout delay prevents rapid cycling compensated resistor type wall thermostats
· Single hole mounting (.25 inch diameter)
· Non-positional
· Brownout protection prevents startup when voltage is below normal conditions
· Reduces nuisance service calls due to short cycling
· Delay on Break Lockout delay starts with opening of thermostat or loss of power
· .25 in. quick-connect terminals
· Eliminates relay chatter due to thermostat bounce
· Small size 2.00 x 2.00 x .75 in.
· UL and CSA listings available

32381
Operation: On initial closure of the thermostat, the compressor relay energizes immediately. When the thermostat opens, a lockout condition and a time delay is initiated. During this lockout time delay period, the compressor cannot be energized. Brownout protection prevents energizing of the compressor when the line voltage is below normal conditions.

With Integral Brownout Protection

MARS NO.

MODEL NO.

OPERATING VOLTAGE (NOMINAL)

32381

TA24A3

24 VAC

32382

TA24A5

24 VAC

TIME DELAY (MIN.) ± 2%
3
5

MARS NO.
1.5 1.5

Low pressure switch bypass application.
FIGURE 1 LOAD IS BYPASSED ON RETURNS TO CIRCUIT AFTER DELAY PERIOD.

MARS TYPE TIME DELAY TYPE OF INPUT NO. DELAY RANGE ADJ. VOLTAGE

HZ

MAX VOLTAGE CONN. AMPS DROP DIAGRAM

32395 by-pass 6 sec...8 min. dial 19...240VAC 50/60 1 2 at 1 amp. 1

C­38

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com

COMPONENTS

MARS Solid State Timers & MARS 3/4" Motor Protectors

MARS Fan Delay/Post Purge Timers

These MARS solid state timers provide for convenient control of a variety of functions. MARS number 32393 is a fixed 2 minute, 24V off-delay timer that allows the fan to continue to operate after the thermostat is satisfied to purge the ducts of conditioned air.
Features: · Wide selection of models · Easy installation · Compact size · Mounts in any position · Totally solid state · High accuracy
Specifications: · 100 milliamps minimum
latch current

32393

MARS Universal Replacements for Refrigeration and Air Conditioning
30 MARS motor protectors solve the serviceman's most annoying problem--finding suitable replacements for motor overload protectors.
Features:
· Used in refrigeration, room air conditioners, heating, appliances, and electric motors
· Each overload has six-inch leads and two wire nuts for simple installation
· UL and CSA listings available

35009

Application Survey By Horsepower*

MARS NO.

110/115

HORSEPOWER

208/240V

1/20 1/12 1/8 1/6 1/5 1/4 1/3 1/2 1/12 1/8 1/6 1/5 1/4 1/3 1/2 1

35010 n n n n n n n n n n n n n n n n

With the switch closed, the load is energized. when the switch opens, the load remains energized and the time delay begins. at the end of the delay
period the load is de-energized.

When the switch closes, the time delay begins. at the end of the delay period, the load is de-
energized.

MARS TYPE TIME DELAY TYPE OF INPUT NO. DELAY RANGE ADJ. VOLTAGE

HZ

MAX VOLTAGE CONN. AMPS DROP DIAGRAM

32393 off delay 2 min. fixed --

24 VAC 50/60 1

2 at 1 amp.

1

35011 n n n n n n n n n n n n n n n n 35012 n n n n n n n n n n n n n n n n 35014 n n n n n n n n n n n n n n n n 35015 n n n n n n n n n n n n n n n n 35016 n n n n n n n n n n n n n n n n 35017 n n n n n n n n n n n n n n n n 35018 n n n n n n n n n n n n n n n n 35019 n n n n n n n n n n n n n n n n

3/4" A/C Overloads

MARS NO.

TEMPERATURE CODE

35101 35105

MRA-3763-529 MRP-00-AIU-529

*Motor protectors cannot be replaced by horsepower, amperage, or nameplate data alone. Refer to cross reference information for proper replacement of original equipment motor protectors by part number.

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

C­39

COMPONENTS

Klixon 3-Phase Motor Protectors & Commercial Refrigeration Thermostats

On-Winding Overheat Protection

Refrigeration Cases and Coils

Klixon SL-11 kits are mounted on the windings of general purpose motors and hermetically sealed
®
compressors. They supplement conventional current overload relays in magnetic starters providing modern total protection for most older motors in use today.

Features:

· Allow motors to perform at full-load capacity but will protect against dangerous running overloads

37090

· Protect against blocked ventilation, high ambient temperatures, single phasing

· Each kit contains three matched motor-winding thermostats

· When starter overloads operate, the SL-11 will protect against re-starting at unsafe winding temperatures.

· These motor winding thermostats do not replace overloads in the starter

· UL & CSA listed

Installation:
SL-11 thermostats are tied in place on the end turns of appropriate winding bundles, one to each phase or buried in the windings during motor rewind. They are connected in series between the starter coil and its power supply.

Selection:
· Pick thermostat temperature to operate at the mid-point between the "maximum normal running" temperature and the "maximum allowed running temperature."
· Subtract the gradient temperature (outlined in the chart below) from the mid-point to obtain the operating temperature of the thermostat.

Epoxy-Sealed Thermostats For General Purpose Motors Normally Closed

MARS NO.

KLIXON KIT NO

KLIXON CAT. NO

OPERATING TEMPERATURE

37075

SL-11-75

37090

SL-11-90

37100

SL-11-100

37110

SL-11-110

37120

SL-11-120

37130

SL-11-130

37135

SL-11-135

37140

SL-11-140

37145

SL-11-145

37150

SL-11-150

Three thermostats per package

9700K51-146 9700K21-146 9700K26-146 9700K36-146 9700K01-146 9700K11-146 9700K06-146 9700K66-146 9700K76-146 9700K46-146

75°C 90°C 100°C 110°C 120°C 130°C 135°C 140°C 145°C 150°C

Typical Gradiants
Motor Type
Open Type Totally Enclosed
Fan Cooled Totally Enclosed Non-Ventilated

Thermostat Location

Tied On End Turns

Buried In End Turns

30°C

15°C

25°C

10°C

20°C

5°C

Maximum Contact Rating Amps Klixon # 24V 115V 230V 9700K 18 18 12

MARS has selected the most popular Klixon disc-type thermostats found in commercial refrigeration. These controls cover a wide assortment of applications including supermarket cases and walk-in, reach-in, and beverage coolers.
Features:
· Used on refrigeration cases, coils, with many other commercial applications
· Long lead wires supplied to satisfy most requirements
· Used by Hussman, Friedrich, Larkin, Schaefer, etc.
· 1 inch discs fully encapsulated for trouble-free use
· Mounts directly on coil tube or surface for maximum temperature response
· UL and CSA listings available
· 25 resistive amps maximum

ELECTRICAL RATING

TERM. TERM.

1-3

1-2

Full load 120V

13

5.8

amps

240V

10

2.9

Locked 120V

60

34.8

rotor amps 240V

45

17.4

Pilot Duty 120/240V 125

125

Resistive 120/240V 25

25

amps

277V

15

15

33405

®
33017

Tube Mounting

MARS NO.

KLIXON NO.

O.E.M.

O.E.M. SWITCH PART NO. ACTION

33405 20420D24-106-63 Bally

--

D

33415 20420D24-399-350

--

D

33420 20428F1-4-676 Friedrich 606-038-00 F

33425 20420L15-913-302

794-824-00 L

33430 20420D1-166-336

--

D

33435 20420L28-229-89 Hussman P211-119696 L

33440 20420F32-381-533

--

F

33455 20420F19-63-294 Schaefer C10872-19 F

33460 20420L19-202-274

C10872-6 L

33470 20420L15-376-218

125211

L

33475 20420L15-722-218 Tyler Ref. 146291

L

33480 20420L15-767-257

146739

L

OPERATING TEMPERATURES F°

OPEN CLOSE

70

20

65

20

35

55

40

25

50

35

20

5

20

30

20

60

35

5

50

30

40

20

80

50

TUBE MT. IN

LEADS IN

5/8 18

5/8 20

3/8 20

5/8 11

1/2 18

3/4 40

3/4 48

5/8 36

5/8 54

5/8 36

5/8 36

5/8 90

Surface Mounting

MARS NO.

KLIXON NO.

O.E.M.

O.E.M. PART NO.

SWITCH ACTION

OPERATING TEMPERATURES F°
OPEN CLOSE

33017 20425L153-B22-B54 Heatcraft 5708L L

75

40

LEADS IN
18 w/ quick connects

1D=SPDT, no. 1 is common (white) - no label, no. 2 either opens or closes temp. rise - red label, no. 3 is opposite of no. 2 - blue label F= close on temperature rise, SPST L= open on temperature rise, SPST 2

C­40

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com

COMPONENTS

Commercial Refrigeration Thermostats & Defrost Thermostats

Change-Over Switches for Fan-Coil Systems

For Defrost Termination

The MARS Series 390 change-
over switches are used for
summer-winter change-over of
®
electric thermo-stats in hydronic
heating - cooling fan-coil units.

Features:
· Color coded leads allow easy installation
· SL-8 thermostat is enclosed in sealed case for trouble-free operation
· Snap-acting disc type, insures accurate temperature repeatability
· Can be mounted in any position
· UL and CSA listings available

39004 Leads thru side

Installation:

The SL-8 change-over switch is located on the main run of the supply line where it can quickly

39005 Leads thru top 1/2" conduit adapter

sense the maximum

temperature of the hot or cold

water passing through. If the SL-8 switch is exposed to

LINE VOLTAGE OPERATION GND LINE HOT

surrounding temperatures, thermal insulation should be wrapped around the switch

FAN COIL UNIT

HEATING SIDE

ROOM THERMOSTAT COOLING SIDE

case to maintain desired thermal response.
Specifications: Pipe size: 5/8 in O.D. Leads: 12 in. color coded

RETURN LINE

MOTORIZED VALVE SUPPLY LINE

 



HOT OR COLD WATER

SL-8 CHANGE-OVER SWITCH

 WHITE COMMON

 BLUE

NORMALLY OPEN

 RED

NORMALLY CLOSED

Switch Action: SPDT

Temperature: 88°F (31°C)-- terminals 1 & 2 close, 1 & 3 open 73°F (23°C)--terminals 1 & 3 close, 1 & 2 open

Mounting: mounting clip supplied with each kit

Electrical: terminals 1 & 3 25 amp at 120/240 VAC

Terminals 1 & 2 10 amp at 120 VAC, 5 amp at 240 VAC

Honeywell MARS

White

MARS

No.

No. Rodgers No, No.

L6076A 39004

752-1

39004

L6076B 39005

752-2

39005

MARS Series 330 defrost controls are designed to replace many defrost thermostats. The leads are of sufficient length for the connection to be made at the same location as was the control removed. The connection should be insulated in a manner similar to that on the original equipment.
The selection of the proper thermostat can be made by matching the temperature code of the thermostat removed to the code on the MARS Thermostat.

33008

Features:
· Refrigerators, A/C units, & heat pumps, dehumidifiers, icemakers or any place where a fixed temperature control is required in a wet or dirty environment.
· Thermostats have 32" leads.

Temp. Code

Use MARS
No.

Temp. Code

Use MARS
No.

Temp. Code

Use MARS
No.

L40-3.0

L58-4.3

L65-4.0

L42-2.0 L45-3.0

33008

L60-2.0 L60-2.5

L67-4.2 L70-4.0

33012

L45-3.0

L60-3.0 33011 L75-5.0

L60-3.5

L55-1.5

L60-4.0

L80-3.0

L55-2.0

L60-4.5

L55-2.5 L55-3.0

33010

L80-4.0 L80-4.5

33020

L80-5.0

L55-3.5

L55-4.0

MARS NO.
33008 33010 33011 33012 33020

TEMP. CODE
L45 L55 L60 L70 L80

OPENING CLOSING TEMP. F° TEMP F°

45

25

55

35

60

40

70

50

80

60

VOLTS
120 240

INDUCTIVE

F.L.A.

L.R.A.

5.8

25

2.9

70

MARS Freeze Stat
The MARS 33101 is designed to help stop flood back to compressor crankcases caused by low ambient temperatures.
Features: · Simple to install · Refrigerators, freezers, A/C,
food dispensing equipment · For use with 1" pipe,
1/2' radius · 24" leads

33101

MARS NO. 39004
39005

KLIXON KIT NO. SL8-5
SL8-5A

KLIXON NO.
20425D27-160-356

DESCRIPTION leads thru side of cup

20425D69-160-287

leads thru top of cup with 1/2" conduit adapter

MARS NO.
33101

OPENING TEMP. F°
34

CLOSING TEMP F°
45

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

C­41

COMPONENTS

Klixon Pressure Switches & MARS Pressure Switches

Fixed Setting Pressure Controls

Low pressure controls.

Specifications:

· Contacts rated at 6 amps,

®

24-240 volts

· 18" leads

Features:

· Tamper proof construction

· Direct mounting on tubing

· UL & CSA recognized

The 4 - Series Klixon Pressure

43341

Switches. This newest set of

designs delivers the reliability and

performance that has made Klixon the most trusted name in the

electromechanical sensor business. The 4 - Series line of pressure

switches covers many new R410A applications along with traditional

pressure setting switches.

Klixon Brand, UL and CUL, Compact size, light weight for direct mounting, Factory Set, Hermetically Sealed Sensor.

5.8 FLA - 34.8 LRA @ 120 VAC, 2.9 FLA - 15.0 LRA @ 240 VAC, 100,000 Cycle Life at Rated Current.

Low Pressure Cut-Out - Open on Pressure Drop, Automatic Reset Normally Open

4 SERIES OPENING RESET PRESMARS NO. PRESSURE SURE

NOTES

43341

5

20

1/4" Female Flare S.A.E. Mounting

43342

5

30

1/4" Female Flare S.A.E. Mounting

43343

10

25

1/4" Female Flare S.A.E. Mounting

43344

15

35

1/4" Female Flare S.A.E. Mounting

43345

20

45

1/4" Female Flare S.A.E. Mounting

43372

22

50

1/4" Copper Clad SS Tube w/38" leads

43373

25

40

Gold Contacts 1/4" Female Flare w/36" leads

43346

25

50

1/4" Female Flare S.A.E. Mounting

43347

25

65

1/4" Female Flare S.A.E. Mounting

43348

25

80

1/4" Female Flare S.A.E. Mounting

43349

35

60

1/4" Female Flare S.A.E. Mounting

43350

40

80

1/4" Female Flare S.A.E. Mounting

43351

45

60

1/4" Female Flare S.A.E. Mounting

43352

50

90

1/4" Female Flare S.A.E. Mounting

43374

50

95

1/4" Copper Clad SS Tube w/36" leads

43353

75

100

1/4" Female Flare S.A.E. Mounting

43375

90

120

1/4" Female Flare, w/18" leads

43354

150

225

1/4" Female Flare S.A.E. Mounting

43355

170

250

1/4" Female Flare S.A.E. Mounting

Fixed Setting Pressure Controls High Pressure Cut-Outs

MARS offers the most complete line of high pressure cut-outs available.
Specifications:
· Contacts rated at 6 amps, 24-240 volts
· 1/4" female flare S.A.E. mounting
· 18" leads

Features: · Tamper proof construction · Direct mounting on tubing · UL & CSA recognized

43337

MARS Pressure Switches deliver the reliability and performance that makes them the most trusted electromechanical sensor. The MARS line of pressure switches cover many new R410A applications along with traditional pressure setting switches.
UL and CUL, Compact size, light weight for direct mounting, Factory Set, Hermetically Sealed Sensor.
5.8 FLA - 34.8 LRA @ 120 VAC, 2.9 FLA - 15.0 LRA @ 240 VAC, 100,000 Cycle Life at Rated Current.

High Pressure Cut-Out - Open on Pressure Rise, Automatic Reset, Normally Closed

MARS NO.

OPENING RESET PRESPRESSURE SURE

43337

200

150

43321

225

150

43322

250

150

43324

275

195

43325

300

200

43326

325

225

43320

350

245

43327

350

250

43328

375

275

43329

400

200

43330

400

280

43331

400

300

43311

410

290

43332

425

300

43333

425

325

43334

450

250

43365

590

418

43335

600

475

43366

610

420

43339

630

480

43367

650

450

NOTES
1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting
1/4" Female Flare S.A.E. Mounting w/24" leads
(1 stripped, 1 w/1/4" female flag QC) 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting
1/4" Female Flare w/snubber 1/4" Female Flare S.A.E. Mounting
1/4" Copper Clad SS Tube, 90 degree elbow w/snubber 1/4" Female Flare S.A.E. Mounting 1/4" Copper Clad SS Tube w/snubber

C­42

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com

COMPONENTS

MARS Pressure Switches & Heat Pump Thermostats

Condenser Fan Cycling Switches

Fan cycling switches provide refrigeration and air conditioning from low ambient conditions.
Specifications:
· Contacts rated at 6 amps, 24-240 volts
· 1/4" female flare S.A.E. mounting
· 18" leads

Features: · Tamper proof construction · Direct mounting on tubing · UL & CSA recognized

43301

Fan Cycling - Close on Pressure Rise

MARS NO.

OPENING RESET PRESPRESSURE SURE

NOTES

43301

75

100

43302

110

170

43303

125

265

43304

150

225

43305

190

275

43370

180

240

43306

210

275

43307

300

400

1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare, S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting

Heat Pump Defrost Thermostats

MARS heat pump defrost thermostats are designed for direct replacement of most existing controls of this type. The temperature settings and tubing sizes have been carefully selected from the most popular OEM settings. Each MARS thermostat comes complete with extra long 54 inch leads, mounting clamp, and installation instructions for fast and simple field installation.

33490

Features:

· Four controls cover most requirements

· Tapered mounting edge for maximum heat transfer

· Extra long 54 inch leads for simple wiring

· Individually boxed with mounting clamp and instructions

· UL & CUL listed

Electrical Ratings:

Cycles X1000

Volts

FLA

100

120VAC

5.8

100

240VAC

2.9

30

120VAC

10.0

30

240VAC

10.0

100

30VDC

­

LRA

Resistive Amps

VA

34.8

10

125

17.4

10

125

40.0

­

­

40.0

­

­

­

1

­

Manual Reset - High Pressure Cut Out Open on Pressure Rise

MARS NO.
33490 33492 33494 33496

OPERATING TEMPERATURES F°

OPEN

CLOSE

80

30

80

30

65

30

65

30

TUBE MOUNTING IN LEADS IN

3/8

54

1/2

54

3/8

54

1/2

54

43312

MARS NO.

OPENING RESET PRESPRESSURE SURE

43312

375

Manual

43313

410

Manual

43314

415

Manual

43315

440

Manual

43316

475

Manual

43368

590

Manual

43369

610

Manual

NOTES
1/4" Female Flare S.A.E. Mounting 1/4" Female Flare S.A.E. Mounting
Capilllary Tube Capilllary Tube 1/4" Female Flare S.A.E. Mounting 1/4" Female Flare w/snubber 1/4" Female Flare w/snubber

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

C­43

COMPONENTS

Compressor Heaters
TUTCOTM Compressor Heaters for A/C and Refrigeration
Features: · Corrosion resistant exterior · High temperature silicone rubber element and insulated leads · 30" leads · Wattage for each model matches compressor requirements · Completely moisture proof · Installs quickly and easily · Nominal power consumption · UL & CSA Listed

Application Reference Chart for TUTCOTM Compressor Heaters

Manufacturer
Aspera Aspera Bendix/Westinghouse Bendix/Westinghouse Bendix/Westinghouse Bristol/Sundstrand Bristol/Sundstrand Bristol/Sundstrand Carrier Carrier Carlysle Copeland Copeland Copeland Copeland Copeland Copeland Fedders/Chrysler Fedders/Chrysler Hitachi Hitachi Hitachi Sanyo Tecumseh Tecumseh Tecumseh Tecumseh Tecumseh Tecumseh Trane Trane Trane Westinghouse Westinghouse

Model
H J A C, D E H10A, H21A, H2EA, H22A H10B, H20B, H21B, H22B H10G, H20G, H21G, H22GN2NG-144 6A25, 26, 28, 29, 6A35, 38, 45, 48 6A88 W (70-88) BR CR JR RR, SR VR Y 3009 2870908 1500FH4-H 305FH2-HE, 402FH2-HE, 505FH2-HE 753FH3-H, 1001FH4-H CR15F, CR20F, CR33F AB, AW AH AJ AK B, C, CL, AG, AV FE, FB D4340/7669 D4340/7670 D4350/689, D4359/690 CD072, CD090 CD072, CD090

MARS No.
32605-32608 32609-32611
32613 32601-32604 32605-32608 32605-32608
32613 32617-32620 32605-32608 32617-32620 32601-32604 32634-32635 32605-32608 32629-32630
32613 32621-32624 32601-32604 32617-32620
32631 32617-32620 32613-32616 32601-32604
32631 32613 32605-32608 32609-32611 32629-32630 32601-32604 32617-32620 32609-32611 32621-32624 32605-32608 32605-32608 32621-32624

32601

MARS NO.

DESCRIPTION

32601 32602 32604 32605 32608 32609 32610 32611 32613 32617 32619 32620 32621 32624 32629 32630 32631 32634 32635

CH-100 CH-100-1 CH-100-3 CH-101 CH-101-3 CH-102 CH-102-1 CH-102-2 CH-103 CH-104 CH-104-2 CH-104-3 CH-105 CH-105-3 CH-135 CH-135-2 CH-197 CH-202-2 CH-202-3

VOLTS
240 208 480 240 480 240 208 120 240 240 120 480 240 480 240 120 240 120 480

WATTS
50
54
60 45 75
50 45 25 70

INCHES

MIN. 30 3/16 30 3/16 30 3/16 27 7/16 27 7/16 25 3/4 25 3/4 25 3/4 24 3/4 41 1/2 41 1/2 41 1/2 32 1/2 32 1/2 20 5/16 20 5/16 13 3/4 33 3/4 33 3/4

MAX 37 37 37 34 1/4 34 1/4 32 9/16 32 9/16 32 9/16 31 9/16 48 5/16 48 5/16 48 5/16 39 5/16 39 5/16 27 1/8 27 1/8 20 9/16 36 3/4 36 3/4

SHAPE
OVL
OVL
OVL OVL RND
RND OVL RND RND

C­44

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com

COMPONENTS

Crankcase Heaters

Direct Replacement Crankcase Heaters for Copeland

Figure 1

32408

Self Regulating Crankcase Heaters
MARS self-regulating crankcase heaters are designed for use with refrigeration compressors up to 5HP and 40 inches in circumference. These heating cables provide peak heat during cold periods and reduced heat when the air temperature rises and should be used in non-hazardous areas. · Cold length: 30" · Heat cable length: 50"

Crankcase Heaters for Copeland
NOTE: All heaters requiring clips or brackets are packaged with the appropriate clips or brackets required.

MARS NO.

COPELAND NO.

WATTS

VOLTS

HEATER LENGTH
IN.

FIGURE

COMPRESSOR MODEL

ACCESSORIES

32408 518-0002-01 100 480 4.25

1 4R, 6R, 6T, 4D, 6D

-

MARS NO. 70970 70971

TYPE Self Regulating Self Regulating

WATTS 32W @ 50°F · 60W @ 0°F 32W @ 50°F · 60W @ 0°F

VOLTS 120 240

Direct Replacement Crankcase Heaters for Carrier
Figure 1

32472 32474

Crankcase Heaters for Carrier

MARS NO.

CARRIER NO.

WATTS VOLTS

HEATER LENGTH IN.

LEAD LENGTH IN.

FIGURE

COMPRESSOR MODEL

32472 HT36FL379 125 120

2.75

32474 HT36FL479 125 240

2.75

60

1

EM:06DM: 306B:50EQ

68

1

EM:06DM: 30HR:30HS

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

C­45

COMPONENTS

Electric Heat

Replacement Coil Kits and Accessories for Electric Heat

MARS Replacement coil kits for electric heat let you repair strip heaters quickly and economically. Each kit contains one close wound, stretch to length, resistance coil with welded terminal bolts; two each male and female ceramic terminal insulators; two each .375 and .450 inch standard ceramic bushings; two each .375 and .450 inch extra long ceramic bushings; necessary nuts, washers, and installation instructions.
Select the right MARS kit from the chart below and order one kit for each circuit to be repaired. Thermal fuse links are rated 22 amp resistor, 15 amp inducer at 120 and 240 VAC.

34602

Features:
· Welded terminal bolts for low resistance and long life
· Close wound coil, stretch to fit many applications
· Complete with bushings, insulators and hardware

MARS

WATTAGE AT

NO.

240V 208V 480V 277V

STRETCHED LENGTH

INCHES

METERS

MIN MAX MIN MAX

34602 5000 3750

--

--

44.62 127.48 1.13

3.24

34604 --

--

5000

--

61.78 176.53 1.57 4.48

34606 --

--

--

5000 59.44 169.82 1.51 4.31

34608 3500 2625

--

--

50.75 145.00 1.29

3.68

34610 --

--

3500

--

42.27 120.76 1.07 3.07

34614 2000 1500

--

--

25.90 74.01 0.66

1.88

34616 2500 1875

--

--

30.89 88.26 0.78

2.24

34620 --

--

--

2500 27.61 78.87 0.70 2.00

34622 1500 1125

--

--

17.04 48.69 0.43

1.24

34624 4500 3375

--

--

42.33 120.95 1.07

3.07

34626 --

--

4500

--

46.05 131.98 1.17 3.35

34630 --

--

2000

--

32.00 108.00 0.81 2.74

34652 6600 4950

--

--

70.56 201.59 1.79

5.12

34654 --

--

6600

--

65.39 186.71 1.66 4.74

34656 6000 4500

--

--

54.43 155.50 1.38

3.95

34658 --

--

6000

--

71.88 205.38 1.83 5.22

34660(1) 5000 3756

--

--

25.00 70.00

--

--

(1) Larger diameter coil - 5/8"

Thermal Fuse Links*

34700

34712

MARS NO.

°F

34700

204

34702

283

34704

333

34706

300

34708

300

34710

227

34712

300

*10 per pack

°C 95.56 139.45 167.22 148.89 148.89 108.33 148.89

DESCRIPTION Fuse Link Fuse Link Fuse Link Fuse Link
Fuse Link­Round Ceramic Base Fuse Link­Oblong Ceramic Base Fuse Link­Oblong Ceramic Base

Replacement Coil Economy Kits

34601

MARS NO.
34600
34601

DESCRIPTION 5000 Watt @ 240 V; includes coil, insulators & hardware 5000 Watt @ 240 V; includes 300° fuse link, coil, insulators & hardware

C­46

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com

COMPONENTS

Relays & Sequencers

Electric Heat Sequencers

A new simple method for selecting and replacing electric heat sequencers with only five basic controls. Replace sequencers in almost any existing system.
Sequencer selection:
A. Determine the number of circuits to be switched. (Electrical rating of auxiliary switch same as main switch.) When more than one (1) sequencer is required the sequencers are to be wired in series with the last switch in each sequencer energizing the control circuit of the next sequencer.
B. Select from the chart the sequencers needed for the number of circuits to be switched. These sequencers may be wired in series to allow sequencing of virtually any number of heating elements and fans.
If the sequencers control the fan/blower circuit, the first switch (M1-M2) of each sequencer must always control the fan. This provides a fan interlock to insure that the fan will remain on until all elements are de-energized.

33222 33243

Features: · Solid State dependability · Replaces Honeywell and White-Rodgers · Ambient rated from 20°F to 160°F · Used on both separate blower and element and combination blower
and element systems · Total 24 volt control · Standard double quick-connect terminals for combination fan and
element systems · Full-load-rated auxiliary contacts · 7.2 KW combination fan and element rated contacts (23A resistive,
7A motor load) · Non-positional · Voltage and ambient self compensating positive temperature
coefficient (PTC) heater elements · Individually packaged with wiring diagrams for up to seven element
furnaces. · UL and CSA listing available

Schematic

H

H

M1

M2

33243 SPST - 1 switch

H

H

M1

M2

M3

M4

33246 DPST - 2 switches

H

H

M1

M2

H

H

M3

M4

33222 (2)SPST - 2 switches

H

H

M1

M2

M3

M4

H

H

M5

M6

33232 (1)DPST and (1)SPST - 3 switches

H

H

M1

M2

M3

M4

H

H

M5

M6

A1

A2

33233 (2)DPST - 4 switches

NO. OF SWITCHES
1 2 2 3 4

MARS NO.
33243 33246 33222 33232 33233

SWITCH TIMING: MIN-MAX IN SECONDS

SWITCH SEQUENCE

SWITCH NO.1 SWITCH NO.2 SWITCH NO.3 SWITCH NO.4 (2)

TERMINALS TERMINALS TERMINALS TERMINALS

M1 / M2

M3 / M4

M5 / M6

A1 / A2

REPLACES FIRST ON LAST ON KLIXON NO. LAST OFF FIRST OFF

ON

OFF

ON

OFF ON OFF

ON

OFF

6000AOM

(1)

1-60 1-45

6000EOM

(1)

1-60 1-45 1-60 1-45

51172-22

No. 1

No. 2 1-24 45-75 30-70 1-40

51172-32 No. 1, No. 2 No. 3 1-24 45-75 1-24 45-75 30-70 1-40

51172-33 No. 1, No. 2 No. 3, No. 4 1-24 45-75 1-24 45-75 30-70 1-40 30-70 1-40

Contact Rating Chart

VAC

RES AMPS

FLA

LRA

120

30

23

84

240

30

23

60

277

23

23

42

480

12.5

5

10

PILOT DUTY VA
672 960 775 400

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

C­47

COMPONENTS

Relays & Sequencers

Thermal Time Delay Relays Sequencers

These time delay relays are used for a variety of applications in heating and air conditioning. They operate by means of a solid state PTC (positive temperature coefficient) device which heats up as current passes through it from the control circuit. This heat causes a positive, snap-acting disc to make or break the necessary contacts.

SPST

Features:
· Shock & vibration resistant internal snap action automatic reset switch mechanism assures positive make/ break action
· Non-positional
· Wide selection for any application
· Voltage and ambient compensated
· UL and CSA listed
· Used for electric heat, air conditioning, heat pumps, gas & oil furnaces, unit heaters and commercial refrigeration

DPST SPDT

Diagrams:
3 1
H
Single Pole Single Throw

2 1
3

C

H

H

Single Pole Double Throw (Contacts 1 and 3 are normally open)

4

5

1

3

H

H

Double Pole Single Throw

MARS REPLACES NO. KLIXON NO.

33215

G0-18

SWITCH TYPE

CONTROL VOLTAGE
24

DELAY (SEC.)

ON

OFF

1-60

1-45

33217

G4-9

240

20-70

20-80

33241

AOM

24

1-24

45-75

33242

AOM

SPST N.O.

24

30-75

1-40

33243

AOM

24

1-60

1-45

33244

EOM

24

1-24

45-75

33245

EOM

DPST N.O.

24

30-75

1-40

33246

EOM

24

1-60

1-45

33247 COM-21 SPDT 1 & 3 N.O.

24

1-24

15-75

33256

E4

DPST N.O.

120

20-70

20-80

33265

E4

33266

E4

DPST N.O.

240

30-110

15-65

240

20-70

20-80

33267 C4M-13 SPDT 1 & 3 N.O.

240

20-70

20-80

Electric Heat Sequencers
The MARS heat sequencers are used in a variety of applications, including electric furnaces, baseboard heaters, heat pump blower control and heating element control. The sequencers stage electric heat to prevent circuit overload. These units operate by means of a PTC (positive temperature coefficient). The PTC is self current limiting, ensuring stable switching action over a wide rangeof voltages.
Features: · Solid state dependability · Replaces Honeywell, White
Rodgers, and Klixon · 12.5A to 25A contact ratings · Quick connect terminals · Various mounting positions · Shock & vibration resistant · Ambient rated from -50ºF to
165ºF · Full-load rated auxiliary
contacts

33841 33844

Single Load Contact Ratings

RESISTIVE (NON-INDUCTIVE)

VAC

WATTS

AMPS

MOTOR RATINGS (INDUCTIVE)

FULL LOAD

LOCKED ROTOR

PILOT DUTY

120

3000

25

10A

60A

125VA

240

6000

25

5A

30A

125VA

480

6000

12.5

3A

18A

480VA

Combined Load Ratings: 30A @ 240VAC - Total: 23A non-inductive + 7FLA / 42LRA inductive Life at rated current: 10,000 cycles

MARS NO.

TIM.

SW.

M1-M2 M3-M4 M5-M6 M7-M8 M9-M10 M1-M2 M3-M4 M5-M6 M7-M8

M9M10

33841 1 1 1-20 -

-

-

- 40-110 -

-

--

33842 1 1 - - 30 - 90 -

-

- - 1-30 - -

33844(1) 1 2 1-20 g 1-20 -

-

- 40-110g40 - 110 -

--

33845 1 2 -

- 30-90 g 30-90 -

-

- 1-30 g 1-30 -

33832(1) 2 3 1-110 g 1-110 1-110 -

- 1-110 g 1-110 1-110 - -

33833(1) 2 4 1-110 g 1-110 1-110 g 1-110 - 1-110 g 1-110 1-110 g1-110 -

33848(1)(2) 4 5 1-160 g 1-160 1-160 1-110 1-160 1-160 g1-160 1-160 1-160 1-160

(1) M1-M2 and M3-M4 are always first switches to turn ON and to turn OFF. All other switches are random ON and random OFF (2) #33848 - switch contacts designated F1-F2 instead of M1-M2

g These contacts switch simultaneously ON TIME ­ Elapsed time to make contacts after heater is energized (Min. to Max.) OFF TIME ­ Elapsed time to make contacts after heater is de-energized (Min. to Max.) OFF Timings determined after PTC heater has been electrified for a total of 5 minutes.

C­48

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com

COMPONENTS

Fan & Limit Disc Thermostats

Heating Applications

MARS Series 390 thermostats are designed for quick on-the-job replacements. One thermostat, when used in conjunction with only one listed, can solve almost any mounting problems you encounter.
Our thermostats have been carefully selected to cover the widest temperature ranges with the fewest models.
Features:
· Widest range of replacements in the industry
· UL and CSA listings available

Electrical Rating

Terminals Terminals*

1-3

1-2

FL Amps

120v

10

5.8

240v

5

2.9

Res. Amps 120v

25

10

240/277v 25

5

Pilot Duty 120/240/277v 125va 125va

*For Spdt Thermostats

Manual

SPDT
Fan & Limit

Fan Switches - Close On Temperature Rise

MARS NO.

KLIXON TEMP. CODE

TEMPERATURE °F OPEN CLOSE

39006 F110-2

90

110

39007 F120-2 100

120

39008 F130-2 110

130

39009 F140-2 120

140

39010 F150-2 130

150

39011 F160-2 140

160

Manual Reset Limit SwitchesOpen On Temperature Rise

MARS NO.

REPLACES TEMPERATURE

KLIXON

°F

TEMP. CODE OPEN °F

39099

MR125

125

39037

MR140

140

39038

MR150

150

39039

MR160

160

39095

MR170

170

39096

MR180

180

39097

MR190

190

39098

MR200

200

39040

MR210

210

39042

MR240

240

39043

MR300

300

Limit Switches - Open On Temperature Rise

MARS NO.

KLIXON TEMPERATURE °F TEMP. CODE CLOSE OPEN

39086 L125-2 105

125

39087 L130-4

90

130

39018 L140-4 100

140

39019 L150-4 110

150

39020 L160-4 120

160

39021 L170-4 130

170

39022 L180-4 140

180

39023 L190-4 150

190

39024 L200-4 160

200

39025 L210-4 170

210

39026 L220-4 180

220

39027 L230-4 190

230

39028 L240-4 200

240

39029 L250-4 210

250

39030 L270-4 230

270

39031 L300-4 260

300

39033 L350-4 310

350

Single Pole Double Throw Switches

MARS NO.

KLIXON TEMP. CODE

TEMPERATURE °F

1-2 OPEN 1-2 CLOSE

OPEN

CLOSE

39078 D140-2 120

140

39045 D150-2 130

150

39081 D170-2 150

170

Adjustable Fan or Limit Thermostats

MARS adjustable fan or limit thermostats let you reduce inventory and still have on hand the most popular thermostat ratings.
MARS adjustable thermostats Are easily set for the desired temperature by turning the indicator dial built into the control. Each MARS adjustable thermostat features integral 2 hole oval mounting flanges.

Features: · Easy dial adjustment · Six controls cover most
requirements · Intergral oval flange · UL and CSA listings available

MARS NO.
39205 39210 39220 39225 39230 39235

TYPE
Fan Fan Limit Limit Limit Limit

RANGE °F
90-130 140-180 135-175 175-215 210-250 250-290

39205

DIFF. °F
20 20 40 40 40 40

SWITCHING ACTION
Close on rise Close on rise Open on rise Open on rise Open on rise Open on rise

Cross Reference Information

GEM NO. MARS NO. WHITE-RODGERS NO. MARS NO.

AT 012 AT 013 AT 014 AT 015 AT 021 AT 022

39220 39225 39230 39235 39205 39210

3F05-1 3F05-2 3L05-1 3L05-2 3L05-3

39205 39210 39220 39225 39230

MARS 2
35205 35220 35225 35230 35235

MARS NO.
39205 39220 39225 39230 39235

Cross Reference Information

WR

MARS

NO. REPLACEMENT

3F01-110 3F01-120 3F01-130 3F01-140 3F01-150 3F01-160 3F01-180 3F01-200 3F01-350

39006 39007 39008 39009 39010 39011 39112 39113 39017

WR

MARS

NO. REPLACEMENT

3L01-120 3L01-130 3L01-140 3L01-180 3L01-190 3L01-200 3L01-230 3L01-250 3L01-300 3L01-350 3L01-550

39086 39087 39018 39022 39023 39024 39027 39029 39031 39033 39036

WR NO.
3L02-160 3L02-170 3L02-180 3L02-190 3L02-200

MARS REPLACEMENT
39039 39095 39096 39097 39098

3L03-140 3L03-190 3L03-325

39078 39147 39093

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

C­49

COMPONENTS

Fan & Limit Disc Thermostats

Electric Heat High Limit Thermostats

MARS electric heat high limit thermostats are designed for easy accurate replacement of OEM thermostats on electric furnaces. Temperature ratings and differentials have been careful selected for safe operation.
MARS electric heat high limit thermostats feature an exposed matte finish disc for fast response. Easy matching of OEM mountings using the intergal round flange or accessory oval flange.
Features:
· Exposed matte finish disc for fast response
· Twelve models replace most popular OEM thermostats
· Individually bagged with instructions
· UL and CSA listings available

39310

TEMPERATURE °F

MARS NO.

OPEN

CLOSE

DIFFERENTIAL

39310 110

90

20

39312 120

100

20

39314 130

100

30

39316 140

100

40

39318 145

105

40

39320 150

110

40

39324 160

120

40

39326 170

130

40

39328 180

140

40

39330 190

150

40

Pro-Series Heating Service Kit
MARS has selected the most popular fan and limit switches used in heating applications. Each switch has an integral small oval flange to duplicate the most popular mounting. UL and CSA listings available.

39008

MARS NO.
39008 39009 39010 39011 39022 39023 39024

SWITCH TYPE
Fan Fan Fan Fan Limit Limit Limit

KLIXON TEMP. CODE
F130-2 F140-2 F150-2 F160-2 L180-4 L190-4 L200-4

TEMPERATURE °F

CLOSE

OPEN

130

110

140

120

150

130

160

140

140

180

150

190

160

200

TEMPERATURE °C

CLOSE

OPEN

54

43

60

49

66

54

71

60

60

82

66

88

71

93

Home Laundry Applications
MARS has carefully selected the most popular multi-purpose thermostats for home laundry and drier equipment. MARS Operating Limit Thermostats range from 125°F to 180°F and have narrow differentials (20°F).
Features: · UL and CSA listings available.

39086

Operating Limit Thermostats -- Open On Temperature Rise

MARS NO.
39086 39055 39051 39048

KLIXON TEMP. CODE
L125-2 L130-2 L150-2 L180-2

TEMP °F-OPEN
125 130 150 180

TEMP. °F-CLOSE
105 110 130 160

MARS Thermocouples

MARS universal replacement thermocouples are fully equipped with fittings and necessary hardware for quick and easy installation.
Each kit is packaged on a display card for easy identification.
Features:
· High temperature stainless steel element for long life and dependable operation
· Fully equipped with fittings and necessary hardware for quick and easy installation
· Individually display packaged for protection and easy identification

72248 Adapter fittings with each kit

MARS NO.
72218 72224 72230 72236 72248

MODEL NO.
TC-18P TC-24P TC-30P TC-36P TC-48P

LENGTH INCHES
18 24 30 36 48

C­50

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com

COMPONENTS

MARS Universal Silicon Nitride Igniter

MARS Universal Silicon Nitride Igniter is designed to replace over 100 silicon nitride igniter applications. The universal bracket kit is used in a simple series of combinations for a quick and easy installation. Extremely low iron content makes the MARS Universal Silicon Nitride Igniter very durable and reliable. Low energy consumption makes it perfect for any 120 VAC application.

Features: · Gas fired forced air furnaces and boilers · Easy to install · Universal bracket fits most furnaces · Fits over 100 applications

MARS NO.
68040

DESCRIPTION Universal SiN Round Silicone Nitride Igniter

Specifications: · Input voltage 120vac · Time to ignition temperature: 16
seconds · CSA certified · Steady current 1.3 amps
(± 0.3 amps @ 120v)

Hot Surface Igniters

Gas Furnace Igniters
· Compatible with 17, 34, and 45 second warm-up modules · Full 115/120 volt rated (no step down module required for silicon nitride) · Wire nuts or OEM plugs and mounting hardware included · New laminated pictorial cross reference and contractor tri-folds available

19" leads with sleeving and connector 67909
5.5" leads with wire nuts 67916

Flat silicon carbide: The most economical solution. Silicon nitride: The newest technology is virtually indestructible.

Direct Replacements
FLAT SILICON CARBIDE
67914 67915 67916 68017 67917 67925 67918 67919 67920 68016 68013 68014 67915 68015 67909 67921 67924 67923

INDUSTRY RECOGNIZED REFERENCE
41-401 41-402 41-403 41-404 41-405 41-406 41-407 41-408 41-409 41-410 41-411 41-412/41-414 41-238/41-242 Rheem 62-22669-92 Coleman 1474-051P / 052P Lennox 33J37 Goodman B1401015 / B1401018S York 025-32625-000

5.5" leads with wire nuts 67917
67920
67921 67924
68015

Universal
FLAT SILICON CARBIDE 67900
N/A

SILICON NITRIDE
N/A
68040

SUPCO SIG1100 SSN2000

WHITE-RODGERS 21D64-2

67900

®
marsdelivers.com

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

67914 19" leads with wire nuts 67915
67918 67919
67923 67925 68016
C­51

COMPONENTS

Flame Sensors
Flame Sensors
MARS flame sensors are direct OEM replacements. False shutdowns can occur in gas furnaces due to a built up carbon on the flame rod. Incorrect cleaning procedures can also damage the flame rod. Replacing a flame sensor that has triggered a false shutdown is the best preventative maintenance and eliminates nuisance service calls.
· Direct OEM Replacements · Improved Service Life · OEM Mounting Brackets · Ceramic Insulators

MARS No.
67680 67681 67682 67683 67684 67685 67686 67687 67688 67689

Replaces OEM
Goodman Source 1 Source 1 Goodman
Allied Source 1 Source 1 Source 1 Goodman Source 1

OEM Part Number
10735201 SI-02537499000 SI-02530788700
0130F00010 44L48
SI-02535306000 SI-02527773700 SI-02535354000
B1172601 SI-02530802000

67680 67681 67682 67683 67684

67685 67686 67687 67688 67689

C­52

Toll Free (800) 445-4155 · Fax (631) 348-7160 www.marsdelivers.com

®
marsdelivers.com


QuarkXPress(R) 13.21 QuarkXPress(R) 13.21