Owner's Manual for MEAN WELL models including: GSM220B Series, GSM220B Series 220W AC and DC Reliable Green Medical Adaptor, 220W AC and DC Reliable Green Medical Adaptor, AC and DC Reliable Green Medical Adaptor, DC Reliable Green Medical Adaptor, Green Medical Adaptor, Medical Adaptor, Adaptor
GSM220B24-R7B MEAN WELL - РКС Компоненти - РАДІОМАГ
GSM220B48-R7B MEAN WELL - Ð ÐС ÐомпоненÑи - Ð ÐÐÐÐÐÐÐ
File Info : application/pdf, 5 Pages, 384.63KB
DocumentDocument220W AC-DC Reliable Green Medical Adaptor GSM220B series User's Manual Video BS EN/EN60601-1/-1-11 ANSI/AAMI ES60601-1/-1-11 ++ IEC60601-1/-1-11 TPTC004 K60950-1 Features (for GSM220B24 only) Applications 2 pole AC inlet IEC320-C8, Class power unit Mobile clinical workstation Medical safety approved (2 x MOPP) according to Oral irrigator ANSI/AAMI ES60601-1/-1-11 and IEC/BS EN/EN60601-1/-1-11 Extremely low leakage current No load power consumption<0.15W Energy efficiency level VI and meet CoC Version 5 Portable hemodialysis machine Breath Machine Medical computer monitor -30~+70 wide range working temperature Protections: Short circuit / Overload / Over voltage / Over temperature GTIN CODE LED indicator for power on MW Search: https://www.meanwell.com/serviceGTIN.aspx Lifetime > 70K hours Various DC plug quick adapter accessory available (Plug kit sold sperately, please refer to : https://www.meanwell.com/upload/pdf/DC_plug.pdf ) 3 years warranty Description GSM220B is a highly reliable, 220W desktop style single-output green medical adaptor series. This product is equipped with a 2-pin (no FG) standard IEC320-C8 power plug, adopting the input range from 80VAC to 264VAC. The entire series supplies different output voltages between 12VDC and 48VDC that can satisfy the demands for various kinds of medical electrical devices. The circuitry design meets the international medical standards (2*MOPP), having an ultra low leakage current (<100A), fitting the medical devices in direct electrical contact with the patients. With the efficiency up to 94.5% and the extremely low no-load power consumption below 0.15W, GSM220B is compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, EU ErP,and meet Code of Conduct (CoC) Version 5. The supreme feature allows the adaptor to save the energy when it is either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant plastic case, providing the double insulation that effectively prevents electrical shock. GSM220B is approved with the international medical safety certificates. Model Encoding GSM220B 12 - R7B { DC plug type R7B: Standard model,Power DIN 4Pin with lock type Other options available by customer requested (see Page 4~5) Output voltage IEC320-C8 AC inlet Rated wattage Series name Downloaded from Arrow.com. File Name:GSM220B-SPEC 2024-01-26 220W AC-DC Reliable Green Medical Adaptor GSM220B series SPECIFICATION ORDER NO. GSM220B12-R7B GSM220B15-R7B GSM220B20-R7B GSM220B24-R7B GSM220B48-R7B SAFETY MODEL NO. GSM220B12 GSM220B15 GSM220B20 GSM220B24 GSM220B48 DC VOLTAGE Note.2 12V 15V 20V 24V 48V RATED CURRENT 15A 13.4A 11A 9.2A 4.6A CURRENT RANGE 0 ~ 15A 0 ~ 13.4A 0 ~ 11A 0 ~ 9.2A 0 ~ 4.6A RATED POWER (max.) 180W 201W 220W 221W 221W OUTPUT RIPPLE & NOISE (max.) Note.3 80mVp-p VOLTAGE TOLERANCE Note.4 ±5.0% LINE REGULATION Note.5 ±1.0% LOAD REGULATION ±5.0% 80mVp-p ±5.0% ±1.0% ±5.0% 120mVp-p ±4.0% ±1.0% ±4.0% 120mVp-p ±3.0% ±1.0% ±3.0% 150mVp-p ±2.0% ±1.0% ±2.0% SETUP, RISE TIME Note.6 2000ms, 50ms / 230VAC 2000ms, 50ms / 115VAC at full load HOLD UP TIME (Typ.) 24ms / 230VAC 24ms / 115VAC at full load VOLTAGE RANGE Note.7 80 ~ 264VAC 113 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz INPUT POWER FACTOR (Typ.) EFFICIENCY (Typ.) PF>0.91 / 230VAC 90% PF>0.98 / 115VAC at full load 90% 92% 93.5% 94.5% AC CURRENT (Typ.) 4A / 115VAC 2A / 230VAC INRUSH CURRENT (max.) LEAKAGE CURRENT(max.) OVERLOAD Cold start 90A / 115VAC 110A / 230VAC Touch current < 100 A/264VAC 105 ~ 135% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION OVER VOLTAGE 105 ~ 135% rated output voltage Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down WORKING TEMP. -30 ~ +70 (Refer to "Derating Curve") WORKING HUMIDITY 20% ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing TEMP. COEFFICIENT ±0.03% / (0~40) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes OPERATING ALTITUDE Note.8 3000 meters SAFETY STANDARDS ISOLATION LEVEL WITHSTAND VOLTAGE IEC60601-1/IEC60601-1-11, BS EN/EN60601-1/ BS EN/EN60601-1-11, ANSI/AAMI ES60601-1 / ES60601-1-11(3.1 version), CAN/CSA-C22.2 No. 60601-1:14 - Edition 3, EAC TP TC 004, KC K60950-1 (for GSM220B24 only) approved Primary-Secondary: 2xMOPP I/P-O/P: 4KVAC ISOLATION RESISTANCE EMC EMISSION I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH Parameter Standard Conducted emission BS EN/EN55011 (CISPR11), FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B) Radiated emission BS EN/EN55011 (CISPR11), FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B) Test Level / Note Class B Class B SAFETY & EMC (Note. 9) Harmonic current BS EN/EN61000-3-2 Voltage flicker BS EN/EN61000-3-3 BS EN/EN60601-1-2, BS EN/EN61204-3 Parameter Standard Class A ----- Test Level / Note ESD BS EN/EN61000-4-2 Level 4, 15KV air ; Level 4, 8KV contact EMC IMMUNITY RF field susceptibility EFT bursts Surge susceptibility BS EN/EN61000-4-3 BS EN/EN61000-4-4 BS EN/EN61000-4-5 Level 3, 10V/m( 80MHz~2.7GHz ) Table 9, 9~28V/m( 385MHz~5.78GHz ) Level 3, 2KV Level 3, 1KV/Line-Line Conducted susceptibility BS EN/EN61000-4-6 Level 3, 10V Magnetic field immunity BS EN/EN61000-4-8 Level 4, 30A/m OTHERS MTBF DIMENSION PACKING Voltage dip, interruption BS EN/EN61000-4-11 1953.3K hrs min. Telcordia SR-332 (Bellcore) ; 208.7K hrs min. 210*85*46mm (L*W*H) 1.1Kg; 12pcs/14.2Kg/0.81CUFT 100% dip 1 periods, 30% dip 25 periods, 100% interruptions 250 periods MIL-HDBK-217F (25) PLUG CONNECTOR CABLE See page 4~5; Other type available by customer requested See page 4~5; Other type available by customer requested 1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2. DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1F & 47F capacitor. 4. Tolerance: includes set up tolerance, line regulation, load regulation. 5. Line regulation is measured from low line to high line at rated load. NOTE 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. Derating may be needed under low input voltage. Please check the derating curve for more details. 8. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). 9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx Downloaded from Arrow.com. File Name:GSM220B-SPEC 2024-01-26 LOAD (%) 220W AC-DC Reliable Green Medical Adaptor GSM220B series Derating Curve Static Characteristics 100 100 90 For others 80 80 For 12~15V 60 70 LOAD (%) 50 60 40 50 20 40 -30 0 10 20 30 40 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE () 80 90 95 100 110 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz Mechanical Specification 46 Case No. 961A Unit:mm 210 Power LED UL2464 16AWGx4C 1000±50mm 30±3mm 85 AC Inlet IEC320-C8 DC output plug Standard plug: R7B R7B 23 14 KYCON KPPX-4P equivalent Pin Assignment PIN NO. OUTPUT 2 3 1 4 1 +Vo 2 -Vo 3 -Vo 4 +Vo Downloaded from Arrow.com. File Name:GSM220B-SPEC 2024-01-26 220W AC-DC Reliable Green Medical Adaptor GSM220B series DC plug changeable through: (1) Customization of the standard part with an optional DC plug according to the table (MOQ applicable) (2) Quick adapter accessory (sold separately without MOQ) Please refer to below table and online selection guide : https://www.meanwell.com/upload/pdf/DC_plug.pdf Example quick adapter accessory: Optional DC plug: (Available in customized cable or quick adapter) Tuning Fork Style A B C (Straight) Min. DIN 4 Pin with Lock (female) 23 14 KYCON KPJX-CM-4S equivalent DIN 5 Pin (male) 13 425 NEUTRIK XLR NC4FX equivalent 4 1 32 MOLEX 39-01-2060 (4.2mm) equivalent 456 123 FG not connected to output connector Type No. P1J P1M Type No. R7BF Type No. R1B Type No. MIC4 Type No. C6P A B C OD ID L 5.5 2.1 11.0 5.5 2.5 11.0 Pin Assignment PIN No. Output 1 +Vo 2 -Vo 3 -Vo 4 +Vo Pin Assignment PIN No. Output 1 -Vo 2 -Vo 3 +Vo 4 -Vo 5 +Vo Pin Assignment PIN No. Output 1 +Vo 2 +Vo 3 -Vo 4 -Vo Pin Assignment PIN No. 1 Output +Vo 2 +Vo 3 +Vo 4 -Vo 5 -Vo 6 -Vo Quick Adapter Accessory Available for 48V (Current rating: 7.5A max.) None None None None Downloaded from Arrow.com. File Name:GSM220B-SPEC 2024-01-26 220W AC-DC Reliable Green Medical Adaptor GSM220B series AMP 1-480702-0 (6.35mm) equivalent 4 3 2 1 FG not connected to output connector Stripped and tinned leads Type No. C4P Type No. Pin Assignment PIN No. Output 1 +Vo 2 +Vo 3 -Vo 4 -Vo Pin Assignment PIN No. Output L (red,blue) 1 2 1 +Vo L1 (black,white) by customer Length of Land L1 by request (MW's standard length, L: 25 mm, L1: 5 mm) ( NOTE: The wire color is for reference only, please refer to the actual product) 2 -Vo Quick Adapter Accessory None None Installation Manual Please refer to : http://www.meanwell.com/manual.html Downloaded from Arrow.com. File Name:GSM220B-SPEC 2024-01-26