Owner's Manual for MEAN WELL models including: GSM220B Series, GSM220B Series 220W AC and DC Reliable Green Medical Adaptor, 220W AC and DC Reliable Green Medical Adaptor, AC and DC Reliable Green Medical Adaptor, DC Reliable Green Medical Adaptor, Green Medical Adaptor, Medical Adaptor, Adaptor

GSM220B-20240126

wangj

GSM220B24-R7B MEAN WELL - РКС Компоненти - РАДІОМАГ

GSM220B48-R7B MEAN WELL - РКС Компоненти - РАДІОМАГ


File Info : application/pdf, 5 Pages, 384.63KB

PDF preview unavailable. Download the PDF instead.

gsm220b-spec pdfjs
220W AC-DC Reliable Green Medical Adaptor

GSM220B series

User's Manual

Video

BS EN/EN60601-1/-1-11 ANSI/AAMI ES60601-1/-1-11

++

IEC60601-1/-1-11 TPTC004

K60950-1

Features

(for GSM220B24 only)

Applications

2 pole AC inlet IEC320-C8, Class  power unit

Mobile clinical workstation

Medical safety approved (2 x MOPP) according to

Oral irrigator

ANSI/AAMI ES60601-1/-1-11 and IEC/BS EN/EN60601-1/-1-11 Extremely low leakage current No load power consumption<0.15W Energy efficiency level VI and meet CoC Version 5

Portable hemodialysis machine Breath Machine Medical computer monitor

-30~+70 wide range working temperature

Protections: Short circuit / Overload / Over voltage / Over temperature  GTIN CODE

LED indicator for power on

MW Search: https://www.meanwell.com/serviceGTIN.aspx

Lifetime > 70K hours

Various DC plug quick adapter accessory available

(Plug kit sold sperately, please refer to : https://www.meanwell.com/upload/pdf/DC_plug.pdf )

3 years warranty

Description
GSM220B is a highly reliable, 220W desktop style single-output green medical adaptor series. This product is equipped with a 2-pin (no FG) standard IEC320-C8 power plug, adopting the input range from 80VAC to 264VAC. The entire series supplies different output voltages between 12VDC and 48VDC that can satisfy the demands for various kinds of medical electrical devices. The circuitry design meets the international medical standards (2*MOPP), having an ultra low leakage current (<100A), fitting the medical devices in direct electrical contact with the patients. With the efficiency up to 94.5% and the extremely low no-load power consumption below 0.15W, GSM220B is compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, EU ErP,and meet Code of Conduct (CoC) Version 5. The supreme feature allows the adaptor to save the energy when it is either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant plastic case, providing the double insulation that effectively prevents electrical shock. GSM220B is approved with the international medical safety certificates.

Model Encoding GSM220B 12 - R7B

{ DC plug type R7B: Standard model,Power DIN 4Pin with lock type Other options available by customer requested (see Page 4~5) Output voltage IEC320-C8 AC inlet Rated wattage Series name

Downloaded from Arrow.com.

File Name:GSM220B-SPEC 2024-01-26

220W AC-DC Reliable Green Medical Adaptor

GSM220B series

SPECIFICATION

ORDER NO.

GSM220B12-R7B

GSM220B15-R7B

GSM220B20-R7B

GSM220B24-R7B

GSM220B48-R7B

SAFETY MODEL NO.

GSM220B12

GSM220B15

GSM220B20

GSM220B24

GSM220B48

DC VOLTAGE

Note.2 12V

15V

20V

24V

48V

RATED CURRENT

15A

13.4A

11A

9.2A

4.6A

CURRENT RANGE

0 ~ 15A

0 ~ 13.4A

0 ~ 11A

0 ~ 9.2A

0 ~ 4.6A

RATED POWER (max.)

180W

201W

220W

221W

221W

OUTPUT

RIPPLE & NOISE (max.) Note.3 80mVp-p

VOLTAGE TOLERANCE Note.4 ±5.0%

LINE REGULATION Note.5 ±1.0%

LOAD REGULATION

±5.0%

80mVp-p
±5.0% ±1.0% ±5.0%

120mVp-p
±4.0% ±1.0% ±4.0%

120mVp-p
±3.0% ±1.0% ±3.0%

150mVp-p
±2.0% ±1.0% ±2.0%

SETUP, RISE TIME Note.6 2000ms, 50ms / 230VAC 2000ms, 50ms / 115VAC at full load

HOLD UP TIME (Typ.)

24ms / 230VAC 24ms / 115VAC at full load

VOLTAGE RANGE Note.7 80 ~ 264VAC 113 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

INPUT

POWER FACTOR (Typ.) EFFICIENCY (Typ.)

PF>0.91 / 230VAC 90%

PF>0.98 / 115VAC at full load

90%

92%

93.5%

94.5%

AC CURRENT (Typ.)

4A / 115VAC 2A / 230VAC

INRUSH CURRENT (max.) LEAKAGE CURRENT(max.)
OVERLOAD

Cold start 90A / 115VAC 110A / 230VAC Touch current < 100 A/264VAC 105 ~ 135% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed

PROTECTION OVER VOLTAGE

105 ~ 135% rated output voltage Protection type : Shut down o/p voltage, re-power on to recover

OVER TEMPERATURE

Shut down o/p voltage, recovers automatically after temperature goes down

WORKING TEMP.

-30 ~ +70 (Refer to "Derating Curve")

WORKING HUMIDITY

20% ~ 90% RH non-condensing

ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing

TEMP. COEFFICIENT

±0.03% /  (0~40)

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

OPERATING ALTITUDE Note.8 3000 meters

SAFETY STANDARDS
ISOLATION LEVEL WITHSTAND VOLTAGE

IEC60601-1/IEC60601-1-11, BS EN/EN60601-1/ BS EN/EN60601-1-11, ANSI/AAMI ES60601-1 / ES60601-1-11(3.1 version), CAN/CSA-C22.2 No. 60601-1:14 - Edition 3, EAC TP TC 004, KC K60950-1 (for GSM220B24 only) approved
Primary-Secondary: 2xMOPP I/P-O/P: 4KVAC

ISOLATION RESISTANCE EMC EMISSION

I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH

Parameter

Standard

Conducted emission

BS EN/EN55011 (CISPR11), FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B)

Radiated emission

BS EN/EN55011 (CISPR11), FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B)

Test Level / Note Class B Class B

SAFETY &
EMC (Note. 9)

Harmonic current

BS EN/EN61000-3-2

Voltage flicker

BS EN/EN61000-3-3

BS EN/EN60601-1-2, BS EN/EN61204-3

Parameter

Standard

Class A -----
Test Level / Note

ESD

BS EN/EN61000-4-2

Level 4, 15KV air ; Level 4, 8KV contact

EMC IMMUNITY

RF field susceptibility
EFT bursts Surge susceptibility

BS EN/EN61000-4-3
BS EN/EN61000-4-4 BS EN/EN61000-4-5

Level 3, 10V/m( 80MHz~2.7GHz ) Table 9, 9~28V/m( 385MHz~5.78GHz ) Level 3, 2KV Level 3, 1KV/Line-Line

Conducted susceptibility

BS EN/EN61000-4-6

Level 3, 10V

Magnetic field immunity

BS EN/EN61000-4-8

Level 4, 30A/m

OTHERS

MTBF DIMENSION PACKING

Voltage dip, interruption

BS EN/EN61000-4-11

1953.3K hrs min. Telcordia SR-332 (Bellcore) ; 208.7K hrs min. 210*85*46mm (L*W*H)
1.1Kg; 12pcs/14.2Kg/0.81CUFT

100% dip 1 periods, 30% dip 25 periods, 100% interruptions 250 periods MIL-HDBK-217F (25)

PLUG CONNECTOR CABLE

See page 4~5; Other type available by customer requested See page 4~5; Other type available by customer requested

1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.

2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.

3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1F & 47F capacitor.

4. Tolerance: includes set up tolerance, line regulation, load regulation.

5. Line regulation is measured from low line to high line at rated load.

NOTE

6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.

7. Derating may be needed under low input voltage. Please check the derating curve for more details.

8. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).

9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the

EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies."

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )

 Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Downloaded from Arrow.com.

File Name:GSM220B-SPEC 2024-01-26

LOAD (%)

220W AC-DC Reliable Green Medical Adaptor

GSM220B series

Derating Curve

Static Characteristics

100 100

90

For others

80 80

For 12~15V

60

70

LOAD (%)

50 60
40

50 20
40

-30 0

10 20 30 40

50 60

70 (HORIZONTAL)

AMBIENT TEMPERATURE ()

80 90 95 100 110 120 140 160 180 200 220 240 264
INPUT VOLTAGE (VAC) 60Hz

Mechanical Specification
46

Case No. 961A Unit:mm

210

Power LED

UL2464 16AWGx4C 1000±50mm
30±3mm

85

AC Inlet IEC320-C8

DC output plug  Standard plug: R7B
R7B
23 14
KYCON KPPX-4P equivalent

Pin Assignment

PIN NO. OUTPUT

2

3

1

4

1

+Vo

2

-Vo

3

-Vo

4

+Vo

Downloaded from Arrow.com.

File Name:GSM220B-SPEC 2024-01-26

220W AC-DC Reliable Green Medical Adaptor

GSM220B series

 DC plug changeable through: (1) Customization of the standard part with an optional DC plug according to the table (MOQ applicable) (2) Quick adapter accessory (sold separately without MOQ) Please refer to below table and online selection guide : https://www.meanwell.com/upload/pdf/DC_plug.pdf
Example quick adapter accessory:

 Optional DC plug: (Available in customized cable or quick adapter)

Tuning Fork Style
A B

C (Straight)

Min. DIN 4 Pin with Lock (female)

23 14
KYCON KPJX-CM-4S equivalent
DIN 5 Pin (male)

13 425

NEUTRIK XLR NC4FX equivalent

4

1

32

MOLEX 39-01-2060 (4.2mm) equivalent

456 123
FG not connected to output connector

Type No. P1J P1M
Type No. R7BF
Type No.
R1B
Type No. MIC4 Type No.
C6P

A

B

C

OD

ID

L

5.5

2.1 11.0

5.5

2.5

11.0

Pin Assignment

PIN No.

Output

1

+Vo

2

-Vo

3

-Vo

4

+Vo

Pin Assignment

PIN No.

Output

1

-Vo

2

-Vo

3

+Vo

4

-Vo

5

+Vo

Pin Assignment

PIN No.

Output

1

+Vo

2

+Vo

3

-Vo

4

-Vo

Pin Assignment

PIN No. 1

Output +Vo

2

+Vo

3

+Vo

4

-Vo

5

-Vo

6

-Vo

Quick Adapter Accessory
Available for 48V
(Current rating: 7.5A max.)
None
None
None
None

Downloaded from Arrow.com.

File Name:GSM220B-SPEC 2024-01-26

220W AC-DC Reliable Green Medical Adaptor

GSM220B series

AMP 1-480702-0 (6.35mm) equivalent
4 3 2 1
FG not connected to output connector
Stripped and tinned leads

Type No. C4P Type No.

Pin Assignment

PIN No.

Output

1

+Vo

2

+Vo

3

-Vo

4

-Vo

Pin Assignment

PIN No.

Output

L

(red,blue)

1

2

1

+Vo

L1 (black,white) by customer

Length of Land L1 by request

(MW's standard length, L: 25 mm, L1: 5 mm)
( NOTE: The wire color is for reference only, please refer to the actual product)

2

-Vo

Quick Adapter Accessory None
None

Installation Manual
Please refer to : http://www.meanwell.com/manual.html

Downloaded from Arrow.com.

File Name:GSM220B-SPEC 2024-01-26



References

Acrobat Distiller 9.0.0 (Windows); modified using iText 5.5.6 ©2000-2015 iText Group NV (AGPL-version)