IDEAL AP60 PRO & AP80 PRO Air Purifiers
Quick Start Guide
Intended Use
The device is used exclusively for cleaning the ambient air indoors.
For detailed operating instructions, visit www.mbmcorp.com.
Important Safety Instructions
Please follow these safety instructions to prevent fire, electric shock, and injury:
- Only use the device indoors.
- Only use a wall socket that supplies the correct voltage.
- Do not modify or repair the device.
- Do not use the device if the power cable or mains plug is damaged or unstable.
- Ensure the power cable is not crushed or damaged and does not create a tripping hazard.
- Disconnect the plug from the wall socket for cleaning, servicing, or when the device is not in use for extended periods.
- Do not touch the plug or device with wet hands.
- Keep packing material away from children to prevent suffocation.
- Place the device at least 10 cm away from walls.
- Keep the device away from drafts.
- Ensure furniture, fabrics, or other objects do not block air intake/outlet.
- Place the device on a stable, even surface with sufficient air circulation.
- Do not spray insect repellent near the device.
- Do not use in rooms with fuel vapor or metal dust.
- Do not use volatile liquids (petroleum, kerosene, paint thinner, polishing paste) for cleaning.
- Do not expose the device to rain, water, moisture, high humidity, or place it near a sink.
- Ensure no foreign objects enter the outlet grilles.
- Do not use near open flames or sparks.
- The device is not suitable for removing harmful gases like carbon monoxide.
- The appliance is not intended for use by persons with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless supervised.
- Supervise children to ensure they do not play with the appliance.
- Do not block air intake and outlet.
- Keep the air purifier away from direct sunlight, naked flames, or heat.
- Only use the air purifier in closed interiors within specified technical parameters.
- Do not use the unit near a fire alarm. If the outlet air blows towards a fire alarm, it may respond late or not at all.
- Disconnect the mains plug before cleaning or maintenance.
- Replace the filter cartridge when the filter replacement indicator lights up. Average filter life is approximately 1 year.
- Clean the housing with a lint-free cloth moistened with soapy water.
- Clean the filter cartridge's pre-filter with a vacuum cleaner.
- Do not use solvents.
- Protect the air purifier from water.
- Do not use silicone-containing substances, as they can destroy the air quality sensor.
- Do not test the air quality sensor with high gas or alcohol quantities.
- Clean the textile cover with a vacuum cleaner. The textile cover can be hand-washed (refer to care label).
Battery Safety
WARNING: Chemical Burn Hazard. Keep batteries away from children.
This product contains a lithium button/coin cell battery. If swallowed or if it enters the body, it can cause severe internal burns and lead to death in as little as 2 hours. Always secure the battery compartment. If it does not close securely, stop using the product, remove batteries, and keep away from children. Seek immediate medical attention if batteries are suspected to be swallowed or inserted into the body.
Warning Symbols
- Risk of injury due to electric shock: Always disconnect the mains plug before maintenance, cleaning, moving the device, or changing the filter.
- Do not use spray cans with flammable content near the Air Purifier.
- Do not use any flammable cleaning agents.
Important Information About Batteries and Disposal
Batteries must not be disposed of with household waste. Return used batteries to public collection points or where they are sold. Ensure correct battery polarity. Do not attempt to open, damage, or incinerate batteries. Leaking batteries are dangerous; handle with suitable gloves. Keep batteries out of reach of children. Remove batteries if the device will not be used for an extended period. Dispose of cells properly. Used cells can cause injury. Always use 3V lithium batteries CR2025. Non-rechargeable batteries are not to be recharged. Do not mix old and new batteries, or different types of batteries.
Setting Up / Operation
Fan Speeds
- Press the on/off button (A) to switch the air purifier on or off.
- The air purifier runs in automatic mode. The fan speed (G) automatically adapts to the measured air quality.
- Press the fan speed button (B) to exit automatic mode and set fan speed manually (1, 2, 3, or Turbo T).
- Turbo speed is for fast purification and runs at maximum capacity.
Air Quality Indicator (E)
- Green: good air quality
- Yellow: average air quality
- Red: poor air quality
Filter Replacement Indicator (F)
An illuminated red "F" indicates the filter needs replacing. The filter life is approximately 1 year. Replace sooner if odors are not filtered or if the filter produces unpleasant odors. Only use original IDEAL filter cartridges.
Remote Control
When using for the first time: Remove the protective flap from the battery to activate the remote control.
How to use correctly: Point the remote control at the air purifier's IR receiver (K).
Replacing the battery: Open the battery compartment, remove the old battery, insert a new CR2025 battery with correct polarity, and slide the compartment back.
Function Buttons (Remote Control)
- N: Select fan speed
- P: Switch air purifier on/off
- O: Switch to automatic mode
- Q: Switch to Quiet mode
- R: Select timer time
- S: Lock/unlock buttons on the control panel. The lock can also be removed by disconnecting the air purifier from the mains or by holding the on/off button (A) on the device.
Note: When operating the remote, the air quality indicator (E) lights up briefly. If the locking function is active and a control panel button is pressed, the air quality indicator (E) lights up briefly in red.
Changing the Filter
Replace the filter cartridge as indicated by the filter replacement indicator (F). No tools are required. Only use original IDEAL filter cartridges. The air purifier automatically detects a new filter insertion and resets the indicator.
Technical Data
IDEAL AP60 PRO
Power supply | 200-240V~50/60Hz / 100-120V~50/60Hz |
Power consumption | 90W (200-240V) / 75W (100-120V) |
Suitable for rooms | 50 to 70 m² * |
Air flow rate (max.) | 600 m³/h |
Dimensions (L x W x H) | 468 x 275 x 668 mm |
Weight | 15 kg |
Volume at turbofan speed T (max.) | 56,6 dB(A) |
Volume in Quiet mode (min.) | 16,5 dB(A) |
IDEAL AP80 PRO
Power supply | 200-240V~50/60Hz / 100-120V~50/60Hz |
Power consumption | 175W (200-240V) / 180W (100-120V) |
Suitable for rooms | 70 to 90 m² * |
Air flow rate (max.) | 750 m³/h |
Dimensions (L x W x H) | 468 x 275 x 668 mm |
Weight | 15 kg |
Volume at turbofan speed T (max.) | 63,4 dB(A) |
Volume in Quiet mode (min.) | 18,7 dB(A) |
* For a room height of 2.50 m
Disposal
This device must not be disposed of with household waste. Hand it in at provided collection points. Recycling electrical and electronic waste conserves valuable resources. Packaging material can be recycled; dispose of it in an environmentally friendly manner.
EC-Declaration of Conformity
This machine is approved by independent safety laboratories and complies with EC regulations. Technical specifications are on the machine's sticker. Subject to alterations without notice.
EC-declaration of conformity
IDEAL AP60 PRO Made in Germany (GS-IDENT. No. 11874101, UL-IDENT. No. 10874101)
IDEAL AP80 PRO Made in Germany (GS-IDENT. No. 11874102, UL-IDENT. No. 10874102)
Complies with:
- 2014/35/EU Low voltage directive
- 2011/65/EU, 2015/863/EU RoHS directive
- 2014/30/EG Electromagnetic compatibility directive
Applied harmonised standards include IEC, EN, and BS standards related to electromagnetic compatibility, safety, and hazardous substances.
Date: 09.02.2022
Authorized representative for technical documentation: Krug & Priester GmbH & Co. KG, Simon-Schweitzer-Str. 34, D-72336 Balingen (Germany)
Certifications: The company Krug + Priester has certifications for Quality (ISO 9001:2015), Environmental (ISO 14001:2015), and Energy Management (ISO 50001:2018).
Supplier's Declaration of Conformity (FCC)
This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: (1) no harmful interference, and (2) acceptance of any interference received.
Manufacturer: KRUG + PRIESTER GMBH & CO KG, Simon-Schweitzer-Straße 34, 72336 Balingen, Germany
U.S. Responsible Party: MBM Corporation, 3134 Industry Drive, North Charleston SC, 29418, Tel: 843-552-2700, Mail: info@mbmcorp.com
Trade Name: IDEAL
Models: AP 30/40/60/80/140 PRO
Classification: FCC Part 15B
The equipment was tested conforming to applicable FCC rule parts and measurement standards. Production units will continue to comply.
Note: This equipment has been tested and found to comply with limits for a Class B digital device. To prevent harmful interference, install and use according to instructions. If interference occurs, try measures like reorienting the antenna, increasing separation, connecting to a different circuit, or consulting a dealer/technician.
To ensure compliance with FCC and ISED RF exposure requirements, this device must be installed to provide a minimum of 20cm between the device and people.