Instruction Manual for SKYRC models including: S100neo, S100neo AC and DC Smart Balance Charger, AC and DC Smart Balance Charger, DC Smart Balance Charger, Smart Balance Charger, Balance Charger, Charger
3 days ago —
File Info : application/pdf, 32 Pages, 1.50MB
DocumentDocumentS100 SKYRC S100neo Instruction Manual AC/DC Smart Balance Charger Instruction Manual V1.0 SK-100202 1. SKYRC S100neo SKYRC S100neo Instruction Manual Introduction 1 What is included 1 Meet S100neo 2 Specification 3 Warning 5 Standard Battery Parameters 6 Buttons Explained 7 Program Flow Chart 8 Power and Battery Connection 10 Charging 12 Lithium Battery Program(LiPo/LiIon/LiFe/LiHV) 14 NiMH/NiCd Battery Program 15 Pb Lead-Acid Battery Program 16 Voltage Calibration (For expert user only) 20 Battery Voltage Meter 20 Battery Resistance Meter 21 Battery Temperature Test 21 Firmware Upgrade 22 Charge Settings 23 System Setting 24 Errors and Warnings 26 Conformity Declaration 27 Warranty and Service 28 SKYRC S100neo 2. SKYRC S100neo Instruction Manual Introduction Congratulations on your choice of SkyRC S100neo smart charger. S100neo boasts a stylish and ultra-compact design, but operating it effectively requires some knowledge. These operating instructions aim to quickly acquaint you with its functions. Therefore, it's vital to thoroughly review the Operating Instructions, Warnings, and Safety Notes before using S100neo. We hope it provides years of satisfaction and success. S100neo, an AC/DC smart charger with a 200W maximum output, accommodates various battery chemistries (LiPo/LiIon/LiFe/LiHV/NiMH/NiCd/Pb) and serves as a power supply, offering adjustable voltage (2.0V-30.0V) and current (1.0A-12.0A) per output. Additionally, it allows voltage measurement without power on, simplifying battery voltage assessment. Before initial use, please read these INSTRUCTIONS, WARNINGS, and SAFETY NOTES carefully! Mishandling batteries and chargers poses significant risks, including fire and explosions! What is included SkyRC S100neo charger*1 User Manual*1 AC power Cord*1 1. SKYRC S100neo SKYRC S100neo Instruction Manual Meet S100neo LCD Display Temperature Sensor Port Balance Port Main Port DC Input 6.0-30.0V/12A SKYRC S100neo 2. Selection Buttons Confirm Button Selection Buttons Type-C Port Smart Ventilation Fan AC Input 100-240V Specification SKYRC S100neo Instruction Manual Item Model Input Voltage Input Current Charge Power Discharge Power Charge Current Discharge Current Balance Current Trickle Charge Current Battery Types Option AC DC DC AC DC Main Port Main Port+Balance Port LiPo/LiIon/LiFe/LiHV/ NiMH/NiCd/Pb LiPo/LiIon/LiFe/LiHV/ NiMH/NiCd/Pb LiPo/LiIon/LiFe/LiHV NiMH/NiCd LiPo/LiIon/LiFe/LiHV NiMH/NiCd Pb Specification S100neo 100-240V (50/60Hz) 6V-30V 12.0A 100W(±10%) 200W(±10%) 5W(±20%) 20W Max (Lipo 6s Discharge) 0.1A~0.5A (±0.1A) 0.6A~10A (±10%) 0.1A-0.2A (±0.1A) 0.3A-2A (±10%) 1000mA Max 50~300mA & OFF Default: 60mA 1-6S 1-15S 3S/6S/12S 3. SKYRC S100neo SKYRC S100neo Instruction Manual Working Modes DC Power Supply LiPo/LiIon/LiFe/LiHV NiMH/NiCd Pb Voltage Current Over Current Protection Size Weight Working Environment Storage Environment DC Motor Run-In Power Length*Width*Height Net Weight Working Temperature Working Humidity Storage Temperature Storage Humidity Voltage Current DIRECTION Time Motor Stall Protection Over Current Protection SKYRC S100neo 4. Balance CHG, Charge, Discharge, Storage Charge, Discharge, Re-Peak, CYCLE_ D_C, CYCLE_C_D Normal, AGM Charge, Cold Charge, Discharge 2v~30V 0.1A~10A (voltage 2V~2.9V) 0.1A~12A (voltage 3V~30V) 0.1A (±0.1A) 0.2A~4A (±20%) 4.1A~10A (±10%) 10.1A~12A (±5%) AC Input: 100W Max DC Input: 200W Max 105*105*62mm about 340g 0-40°C 0%-75% -10°C-70°C 0%-75% 3.0V-12.0V 1.0A-5.0A FORWARD 1-60min Overload Protection SKYRC S100neo Instruction Manual Warning S100neo is not intended for use by persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the charger by a person responsible for their safety. Failure to exercise caution while using this product and comply with the following warnings could result in a product malfunction, electrical issues, excessive heat, FIRE, and ultimately injury and property damage. Never leave charging batteries unattended during use. Never charge batteries overnight. Never attempt to charge dead, damaged, or wet battery packs. Never attempt to charge a battery pack containing different types of batteries. Never charge batteries in extremely hot or cold places or place in direct sunlight. Never charge a battery if the cable has been pinched or shorted. Never connect the charger if the power cord has been pinched or shorted. Never attempt to dismantle the charger or use a damaged charger. Never attach your charger to both an AC and a DC power source at the same time. Always use the charger with the correct charging and discharging program. Always use only rechargeable batteries designed for use with this type of charger. Never use the charger on car seats, carpets, or similar surfaces. Always operate the charger away from flammable and explosive materials. 5. SKYRC S100neo SKYRC S100neo Instruction Manual Standard Battery Parameters LiPo Lilon LiFe LiHV NiMH NiCd Pb Nominal voltage 3.7V/cell 3.6V/cell 3.3V/cell 3.8V/cell 1.2V/cell 1.2V/cell 2.0V/cell Max. charge voltage 4.2V/cell 4.1V/cell 3.65V/ cell 4.35V/ cell 1.5V/cell 1.5V/cell 2.4V/cell Storage voltage 3.8V/cell 3.7V/cell 3.3V/cell 3.85V/ cell N/A N/A N/A Allowable fast charge current 1C 1C 4C 1C 1C-2C 1C-2C 0.4C Min. discharge 3.0- 2.9- 2.6- 3.1- 0.6- 0.6- 1.8- voltage 3.4V/cell 3.3V/cell 3.0V/cell 3.5V/cell 1.0V/cell 1.0V/cell 2.0V/cell Select the correct operating procedure in accordance with the battery parameters. Incorrect settings may cause the battery to burn or even explode. SKYRC S100neo 6. Buttons Explained SKYRC S100neo Instruction Manual Go through the menus or increase the parameter value Enter the setting, confirm the choice and stop the progress Go through the menus or decrease the parameter value 7. SKYRC S100neo SKYRC S100neo Instruction Manual Program Flow Chart Cell Voltage V 1 4.05 4 4.05 2 4.05 5 4.05 3 4.05 6 4.05 :25.2V : 8mV Batt IR m 1 13 4 10 2 12 5 17 3 15 6 16 :77m WARNING! NEVERUSETHE CHARGER UNSUPER VISED! LiPo/6S/Balance CHG 0.00 V 0 0.00 A W 0 mAh 0.0Wh 00:00:00 Long Press Charge Setting Task Parameters System Setting DC Power Battery Meter Factory Settings System Info System Upgrade Back Charge Setting Battery Type: LiPo Battery Cell: 6S(22.2V) Task: Balance CHG Condition: 4.20V Charge Current: 10.0A Start Back Charge Setting Battery Type: LiPoLiPo Battery Cell: 6S(L2il2o.2V) LiFe Task: BalanLceiHCVHG Condition: NiM4.H20V Charge Setting Task Parameters System Setting DC Power Battery Meter Factory Settings System Info System Upgrade Back Charge Setting Battery Type: LiPo Battery Cell: 6S(22.2V) Task: Balance CHG Condition: 4.20V Charge Current: 10.0A Start Back Charge Setting Battery Type: 1SLiPo Battery Cell: 6S(22S2.2V) 3S Task: Balanc4eSCHG Condition: 54S.20V Charge Setting Task Parameters System Setting DC Power Battery Meter Factory Settings System Info System Upgrade Back Charge Setting Battery Type: LiPo Battery Cell: 6S(22.2V) Task: Balance CHG Condition: 4.20V Charge Current: 10.0A Start Back Charge Setting Battery TyBpael:ance CLHiPGo Battery Cell: C6hSa(r2g2e.2V) Storage Task: BDaliasnchcearCgeHG Condition: 4.20V Charge Setting Task Parameters System Setting DC Power Battery Meter Factory Settings System Info System Upgrade Back Charge Setting Battery Type: LiPo Battery Cell: 6S(22.2V) Task: Balance CHG Condition: 4.20V Charge Current: 10.0A Start Back Charge Setting Condition: 4.148.V20V Charge Current:4.1190V.0A 4.20V Start 4.21V Back 4.22V Charge Setting Task Parameters System Setting DC Power Battery Meter Factory Settings System Info System Upgrade Back >Task Parameters Safety Timer: 240Minute Max. Capacity: 12000mAh Trickle Charge: 60mA Holding Voltage: ON Back SKYRC S100neo 8. >System Setting Language: English Min. Input Voltage: 11.0V LCD BackLight: Low Volume: Low Completion Signal: Once Warning ON Back >DC Power Voltage: Current: Start Back 12.0V 4.2V DC Power CV 11.86 A 46 4.89 V W Set: 12.00V 5.00A >Battery Meter V 1 4.05 2 4.05 3 4.05 :25.2V 4 4.05 5 4.05 6 4.05 : 8mV Batt IR m 1 13 2 12 3 15 :77m 4 10 5 17 6 16 >Factory Settings Restore Factory Settings? YES NO SKYRC S100neo Instruction Manual Charge Setting Battery Type: LiPo Battery Cell: 6S(22.2V) Task: Balance CHG Condition: 4.20V Charge Current: 10.0A Start Back Charge Setting Battery Type: LiPo Battery Cell: 6S(22.2V) Task: Balance CHG Condition: 4.20V Charge Current: 10.0A Start Back Charge Setting Battery Type: LiPo Battery Cell: 6S(22.2V) Task: Balance CHG Condition: 4.20V Charge Current: 10.0A Start Back Charge Setting Condition: 9.64A.20V Charge Current:9.71A0.0A 9.8A Start 9.9A Back 10.0A Charge Setting Task Parameters System Setting DC Power Battery Meter Factory Settings System Info System Upgrade Back LiPo/6S/Balance CHG 22.96 V 200 8.73 A W 2235 mAh 50Wh 00:15:08 Charge Setting Task Parameters System Setting DC Power Battery Meter Factory Settings System Info Regulatory Back LiPo/6S/Balance CHG 0.00 V 0 0.00 A W 0 mAh 0.0Wh 00:00:00 Charge Setting Task Parameters System Setting DC Power Battery Meter Factory Settings System Info System Upgrade Back >System Info Hardware Version: 1.00 Firmware Version: 1.51 SN: 31300303139380100 00000000133010097 >Regulatory LiPo/6S/Balance CHG 0.00 V 0 0.00 A W 0 mAh 0.0Wh 00:00:00 9. SKYRC S100neo SKYRC S100neo Instruction Manual Power and Battery Connection 1. Connect to power source There are two options of inputs for SKYRC S100neo: AC 100-240V or DC 6-30V. AC 100-240V *12V DC Battery or 6-30V DC Power Supply 12V DC Battery 2. Connect the battery TO AVOID SHORT CIRCUITS, ALWAYS CONNECT THE CHARGE LEADS TO THE CHARGER FIRST AND THEN TO THE BATTERY. REVERSE THE SEQUENCE WHEN DISCONNECTING. SKYRC S100neo 10. SKYRC S100neo Instruction Manual 1) LiPo Battery Connection with Balance Adapter For safety reasons, it is highly recommended to charge Lithium batteries (LiPo, Lilon, LiFe and LiHV) using Balance CHG mode unless the battery comes without a balance connector. The battery balance connector must connect to the charger with the black wire aligned with the negative marking. Ensure correct polarity! 2) NiMH/NiCd or Pb Battery Connection Li Battery 11. SKYRC S100neo SKYRC S100neo Instruction Manual Charging Various operations are applicable depending on the battery type. This chart illustrates operations relevant to different types of batteries. Battery Type LiPo Lilon LiFe LiHV Working Mode Balance CHG Charge Storage Discharge Description This mode is to balance charge the lithium battery based on the charging rate the user set. It can balance each cells of the battery. This mode is to charge the lithium battery based on the charging rate selected. This mode is to store the battery via charging or discharging its voltage to a specific storage value. This mode is to discharge the lithium battery based on the discharging rate selected. SKYRC S100neo 12. SKYRC S100neo Instruction Manual Battery Type NiMH NiCd Pb Working Mode Description Charge This mode is to charge the NiMH/NiCd battery based on the charging rate selected. Discharge Re-Peak Cycle_D_C Cycle_C_D Normal This mode is to discharge the NiMH/NiCd battery based on the discharging rate selected. In re-peak charge mode, the charger can peak charge the battery twice in a row automatically. This is good for confirming the battery is fully charged. 1 to 3 cyclic and continuous process of discharge>charge is operable for refreshing and restoring the performance of NiMH/NiCd batteries. 1 to 3 cyclic and continuous process of charge>discharge is operable for refreshing and restoring the performance of NiMH/NiCd batteries. This mode is to charge the Pb battery based on the charging rate selected. AGM Charge This mode is to charge the AGM battery based on the charging rate selected. Cold Charge This mode is to charge the Pb battery under a low temperature based on the charging rate selected. Discharge This mode is to discharge the Pb battery based on the discharging rate selected. 13. SKYRC S100neo SKYRC S100neo Instruction Manual Lithium Battery Program(LiPo/LiIon/LiFe/LiHV) Here is a flowchart to guide you to set up the program. Charge Setting Battery Type: LiPoLiPo Battery Cell: 6S(L2il2o.2V) LiFe Task: BalanLceiHCVHG Condition: NiM4.H20V Select Battery Type Press button to call out the Battery Type menu, and select LiPo. Charge Setting Condition: 9.64A.20V Charge Current:9.71A0.0A 9.8A Start 9.9A Back 10.0A Select Charge/ Discharge Current Press and button to select the current. Charge Setting Battery Type: 1SLiPo Battery Cell: 6S(22S2.2V) 3S Task: Balanc4eSCHG Condition: 54S.20V Select Battery Cell Press and button to select the correct battery cells. Charge Setting Condition: 4.20V Charge Current: 10.0A Start Back Start Press and button to initiate the program. Charge Setting Battery TyBpael:ance CLHiPGo Battery Cell: C6hSa(r2g2e.2V) Storage Task: BDaliasnchcearCgeHG Condition: 4.20V Select Task Press and button to select your desired working mode. Charge Setting Condition: 4.148.V20V Charge Current:4.1190V.0A 4.20V Start 4.21V Back 4.22V Select Condition Press and button to select the terminal charging voltage. SKYRC S100neo 14. Charge Setting Condition: 4.20V Charge Current: 10.0A Start Back Back Press and button to step back to the main interface. LiPo/6S/Balance CHG 22.96 V 200 8.73 A W 2235 mAh 50Wh 00:15:08 Stop Press button to stop the program, If prompted to stop, short-press the again to confirm, or short-press the button to return. NiMH/NiCd Battery Program SKYRC S100neo Instruction Manual Charge Setting Battery Type: LiFeLiPo Battery Cell: 6SL(i2H2V.2V) NiMH Task: BalanNceiCCdHG Condition: P4B.20V Select Battery Type Press button tto call out the Battery Type menu, and select NiMH. Charge Setting Battery Type: 1SLiPo Battery Cell: 6S(22S2.2V) 3S Task: Balanc4eSCHG Condition: 54S.20V Select Battery Cell Press and button to select the correct battery cells. Charge Setting Battery Type:ChargeLiPo Battery Cell:R6eS-P(2e2a.k2V) CYCLE_C_D Task: CBYalCanLcEe_DC_HCG Condition:4 Discharg.2e0V Select Task Press and button to select your desired working mode. Charge Setting Battery Type: -4 mLViPo Battery Cell: 6-S5(22m.2VV) -6 mV Task: Balan-7ce mCVHG Condition:4. -8 m2V0V Select Condition Press and button to set the delta voltage. Charge Setting Charge Current 9.6 Temp.Cut-off Start 9.7A 9.8A 9.9A Back 10.0A Charge Setting Charge Current 48°C Temp.Cut-off Start 49°C 50°C 51°C Back 52°C Charge Setting Charge Current Temp.Cut-off Start Back 3.0A 50°C Charge Setting Charge Current Temp.Cut-off Start Back 3.0A 50°C NiMH/8S/Charge 10.47V 25 2.53 A W 234 mAh 12Wh 00:10:09 Select Charge/ Discharge Current Press and button to select the current. Temp. Cut-off Press and button to select the temp. Start Press and button to initiate the program. Back Press and button to step back to the main interface. Stop Press button to stop the program, If prompted to stop, short-press the again to confirm, or short-press the button to return. 15. SKYRC S100neo SKYRC S100neo Instruction Manual Pb Lead-Acid Battery Program Charge Setting Battery Type: LiFeLiPo Battery Cell: 6SL(i2H2V.2V) NiMH Task: BalanNceiCCdHG Condition: P4B.20V Select Battery Type Press button to call out the Battery Type menu, and select PB. Charge Setting Battery Type: LiPo Battery Cell: 6S(32S2.2V) Task: Balanc6eSCHG Condition: 4.20V Select Battery Cell Press and button to select the correct battery cells. Charge Setting Battery Type:NormaLl iPo Battery CeAll:GM6SC(2h2a.r2gVe) Cold Charge Task: BDaliasnchcearCgeHG Condition: 4.20V Select Task Press and button to select your desired working mode. Charge Setting Condition: 2.45V Charge Current: 3.0A Start Back Start Press and button to initiate the program. Charge Setting Condition: 2.45V Charge Current: 3.0A Start Back PB/6S/AGM Charge 22.96 V 200 8.73 A W 2235 mAh 50Wh 00:15:08 Back Press and button to step back to the main interface. Stop Press button to stop the program, If prompted to stop, short-press the again to confirm, or short-press the button to return. Charge Setting Condition: 2.8A Charge Current:2.9A 3.0A Start 3.1A Back 3.2A Select Charge/ Discharge Current Press and button to select the current. SKYRC S100neo 16. DC Power SKYRC S100neo Instruction Manual LiPo/6S/Balance CHG 0.00 V 0 0.00 A W On the main menu, hold the ENTER button for two seconds to enter System Setting>DC Power. 0 mAh 0.0Wh 00:00:00 Long Press System Setting Task Parameters System Setting DC Power Battery Meter *Connect your desired DC equipment. >DC Power Voltage: Current: Start Back 12.0V 4.2V Select the options of DC Power: adjust the output voltage and current. DC Power CV 20.00 V 200 10.00 A W Set: 20.00V 10.00A Select Start to activate the DC Power working mode and then connect your desired DC equipment. 17. SKYRC S100neo SKYRC S100neo Instruction Manual When acting as a digital power supply, S100neo can regulate its output voltage or current at a constant level. Constant Current(CC) Mode and Constant Voltage(CV) Mode can switch automatically as follows: If R load > (V out / I out), then the power supply is in CV mode If R load < (V out / I out), then the power supply is in CC mode Power Supply I-V Diagram, CV Operation Power Supply I-V Diagram, CC Operation It is vital for efficient and precise power delivery in various applications for RC professionals *Benefits of using a CC/CV mode DC power supply explained: 1. Versatility: CC/CV power supplies are versatile because they can switch between constant current and constant voltage modes. This makes them suitable for a wide range of applications, from powering delicate electronics to driving high-power devices. SKYRC S100neo 18. SKYRC S100neo Instruction Manual 2. Protection: The CC mode can prevent overcurrent situations, which could damage electronic devices or create hazardous situations. By setting a maximum current limit, the power supply ensures that it won't deliver more current than the device can safely handle. 3. Battery Charging: CC/CV power supplies are particularly useful for charging lithium-ion batteries, which require a precise charging protocol. Initially, the charger works in CC mode to restore most of the battery's capacity, then switches to CV mode to top off the charge while preventing overcharging. 4. Optimized for Various Loads: Some loads require a specific voltage to operate correctly, while others need a particular current. A CC/CV power supply can adapt to these needs, providing a stable and suitable power output under various load conditions. 5. Improved Efficiency: By dynamically switching between modes depending on the load, a CC/CV power supply can often operate more efficiently than a power supply using only one mode. 6. Safe for LED driving: LEDs are current-driven devices, and a slight increase in voltage can lead to a high current, causing damage to LEDs. CC mode allows safe driving of LEDs. CV mode can be useful when LEDs are configured in parallel strings. 19. SKYRC S100neo SKYRC S100neo Instruction Manual Voltage Calibration (For expert user only) You can calibrate the voltage directly on the charger with a 6S LiPo battery. For more information, please contact us at info@skyrc.com Battery Voltage Meter S100neo measures the lithium battery voltage easily and conveniently. Use the balance port to connect the lithium battery directly to S100neo. S100neo lights up and displays battery voltage without power on. SKYRC S100neo 20. Li Battery SKYRC S100neo Instruction Manual Battery Resistance Meter Power on S100neo, and hold the Start button for seconds to enter the System Setting. Connect the battery to S100neo and scroll down to Battery Meter Press ENTER button to measure the battery voltage and resistance. Press + button to check the resistance value. Press - button to exit the Battery Meter interface. Charge Setting DC Power Battery Meter Factory Settings System Info >Battery Meter V 1 4.05 2 4.05 3 4.05 :25.2V 4 4.05 5 4.05 6 4.05 End >Battery Meter 1 046 2 026 3 024 4 027 5 025 6 030 End Battery Temperature Test Power on S100neo and select the NiMH/NiCd charging mode Connect the temperature sensor and NiMH/NiCd battery Press - button to show battery temperature Charge Setting Charge Current 48°C Temp.Cut-off Start 49°C 50°C 51°C Back 52°C NiMH/8S/Charge 10.47V 25 2.53 A W 234 mAh 12Wh 00:10:09 NiMH/8S/Charge 22.96 V 200 8.73 A W 2235 mAh 50Wh 45°C/113°F 21. SKYRC S100neo SKYRC S100neo Instruction Manual Firmware Upgrade 1. Download the latest Charger Master onto your desktop. Unzip and open it; 2. Press the UP and DOWN buttons, then connect the power cord; S100neo will power on with a blue screen notice. 3. Connect S100neo to your computer via a USB type-C cable; 4. Launch the Charger Master, which will detect the charger automatically; 5. After successful detection, click to check the new version of the firmware; 6. When there is a new version, click to upgrade till the process finishes. SKYRC S100neo 22. SKYRC S100neo Instruction Manual Charge Settings Short press the ENTER button to enter the Charge Setting. Menu Battery Type Definition Select the desired battery type. (LiPo, LiIon, LiFe, LiHV, NiMH, NiCd, PB) Battery Cell Select the number of battery cells by different battery type. (Li-xx: 1-6S, Ni-xx: 1-15S, Pb: 3S/6S/12S) Task Select the work mode to be performed. (Balance CHG, Charge, Storage, Discharge, etc.) Condition Set the cut-off voltage. Current Set the charge or discharge current. Start Start the program. Back Back to the main interface. 23. SKYRC S100neo SKYRC S100neo Instruction Manual System Setting On the main interface, hold the START button for two seconds to enter the System Setting. Menu Task Parameters System Settings Option Safety Timer Max. Capacity Trickle Charge Holding Voltage Back Language Min.Input Voltage LCD BackLight Volume Completion Signal Warning Back Definition Customize a period for program protection. Customize the maximum capacity. Enable/disable trickle charge. Enable/disable holding voltage If the battery voltage is dropped to a specified value, then it will charge the battery automatically with a small current if it's enabled. Back to the previous interface. Select your desired system language. Set the minimum voltage for input protection. Adjust the brightness of the screen. Adjust the volume of the key and beep. Choose the way you'd like to be reminded when the program completes. Enable/disable the start-up warning. Back to the previous interface. SKYRC S100neo 24. Voltage Current DC Power Start Back Battery Meter N/A Factory Settings N/A System Info N/A Regulatory N/A Back N/A SKYRC S100neo Instruction Manual Set the output voltage. (2.0-30.0V) Set the output current. (1.0-10.0A) Enable DC power output and return to the main interface. Back to the previous interface. Measure the battery voltage and internal resistance. Press - to return to the system setting. Restore to the factory settings. Check the current system status. Check the certification information Back to the previous interface. 25. SKYRC S100neo SKYRC S100neo Instruction Manual Errors and Warnings In the event of a fault, the charger will display an error message and sound an alarm. Error Message DC In Too Low DC In Too High Connection Break Overcharge Capacity Limit Over Time Limit Int. Temp Too High Over Load Reversed Polarity Fully Charged Outlet Overload Balance Connection Error Battery Type Error Cell Error Cell Volt Diff. PD In Use, Charging Output N/A! Unplug PD Device Explanation DC input voltage is lower than preset or min.input voltage! DC input voltage is higher than preset! The battery connection is broken! The charged capacity is exceeding the limit! The program times out! The internal temperature is high! The charger is overloaded! The battery connection is reversed! The battery is fully charged already! The output is overloaded. The balance connection is incorrect. The cells do not match. The battery type is wrong! The voltage difference between each cell is high. PD In Use, Charging Output N/A! PD and charger output cannot be used simultaneously. SKYRC S100neo 26. SKYRC S100neo Instruction Manual Conformity Declaration SkyRC B6ACneo satisfies all relevant and mandatory CE directives and FCC Part 15 Subpart B. Test Standards EN 60335-1 EN 60335-2-29 EN 55014-1 EN 55014-2 EN 61000-3-2 EN 61000-3-3 FCC Part Subpart 15B Title Result Household and similar electrical appliances - Safety Part 1: General requirements Conform Household and similar electrical appliances Safety Part 2-29: Particular requirements for battery chargers. Conform Electromagnetic compatibility Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission Conform Electromagnetic compatibility Requirements for household appliances, electric tools and similar apparatus Part 2: Immunity Product Family Standard Conform Electromagnetic compatibility (EMC) Part 3-2: Limits for harmonic current emissions (equipment input current up to and including 16 A per phase) Conform Electromagnetic compatibility (EMC) - Part 3-3: Limitation of voltage supply systems for equipment with rated current 16 A. Conform Title 47 Telecommunication PART 15 - RADIO FREQUENCY DEVICES Subpart B - Unintentional Radiators Conform 27. SKYRC S100neo SKYRC S100neo Instruction Manual Warranty and Service Liability Exclusion This charger is designed and approved exclusively for use with the types of battery stated in this Instruction Manual. SkyRC accepts no liability of any kind if the charger is used for any purpose other than that stated. We are unable to ensure that you follow the instructions supplied with the charger, and we have no control over the methods you employ for using, operating, and maintaining the device. For this reason, we are obliged to deny all liability for loss, damage, or costs that are incurred due to the incompetent or incorrect use and operation of our products, or which are connected with such operation in any way. Unless otherwise prescribed by law, our obligation to pay compensation, regardless of the legal argument employed, is limited to the invoice value of those SkyRC products which were immediately and directly involved in the event in which the damage occurred. Warranty and Service We guarantee this product to be free of manufacturing and assembly defects for a period of one year from the time of purchase. The warranty only applies to material or operational defects, which are present at the time of purchase. During that period, we will repair or replace free of service charge for products deemed defective due to those causes. This warranty is not valid for any damage or subsequent damage arising as a result of misuse, modification, or as a result of failure to observe the procedures outlined in this manual. SKYRC S100neo 28. SKYRC S100neo Instruction Manual Note: The warranty service is valid in China only. If you need warranty service overseas, please contact your dealer in the first instance, who is responsible for processing guarantee claims overseas. Due to high shipping costs, and complicated custom clearance procedures to send back to China, please understand that SkyRC can't provide warranty service to overseas end users directly. If you have any questions which are not mentioned in the manual, please feel free to send an email to info@skyrc.com 29. SKYRC S100neo SKYRC S100neo Instruction Manual . The manual is subject to change without notice; please refer to our website for the latest version! Manufactured by SKYRC TECHNOLOGY CO., LTD. www.skyrc.com 2023 SkyRC Trchnology Co., Ltd. All Rights Reserved SKYRC S100neo 30. [Version 1.0]