MITSUBISHI ELECTRIC EUROPE B.V.

Industrial Automation

Mitsubishi-Electric-Platz 1 40882 Ratingen Deutschland

Telefon +49 (0) 2102 486-0 Fax +49 (0) 2102 486-1120

Website: https://emea.mitsubishielectric.com/fa

MATERIAL FACT SHEET

307216 FR-F840-00170-E2-60

General Data

Product HierarchyIAK24201
Ext. Material Group10
ABC IndicatorA (Available from Stock)
e-shophttps://mitsubishi-electric-eshop.mee.com/mee/FA_IA/EUR/en/p/000000000000600200
FA-InverterInverter
SeriesFR-F800 SERIES
TypeFR-F800-E INVERTER
Minimum Rated Voltage (V)380
Min. Permissible Voltage (V)323
Maximum Rated Voltage (V)500
Max. Permissible Voltage (V)550
Current TypeAC
Phases3
Rated Output Current SLD (A)17
Rated Output Current LD (A)16
Rated Motor Capacity SLD (kW)7,5
Rated Motor Capacity LD (kW)7,5
Frequency Range (Hz)0,2-590
Control MethodMAGNETIC FLUX VECTOR CONTROL
Control Method (2)PM SENSORLESS VECTOR CONTROL
Control Method (3)SOFT-PWM/HIGH FREQUENCY PWM
Control Method (4)V/F CONTROL
Motor TypeINDUCTION MOTOR, PM MOTOR
Integrated EMC FilterYES
Safe Torque Off (STO)YES
Regenerative (4Q)NO
Integrated DC ChokeNO
DisplayFR-DU08
Display Type5 DIGITS LED (12 SEGMENT)
PLC FunctionYES
Program Memory6K
Program Memory UnitSTEPS
Integrated Digital Inputs12
Digital Outputs (Transistor)5
Digital Outputs (Relay)2
Integrated Analogue Inputs3
Integrated Analogue Outputs2
IO Type of Terminal BlockSPRING CLAMP
ExpandableYES
USB1+1 MINI
Ethernet Port1
Built-In NetworkBACNET/IP
Built-In Network (2)CC-LINK IE FIELD NETWORK BASIC
Built-In Network (3)MELSOFT/FA
Built-In Network (4)MODBUS/TCP
Built-In Network (5)SLMP
Built-In Network (6)iQSS
Leakage Current (mA)35(DELTA) / 2(STAR)
Power Loss SLD (W)245
Power Loss LD (W)230
Standby Power Consumption (W)20
Protection ClassIP20

Product Dimensions & Weight

DimensionValue
Width (mm)220
Height (mm)260
Depth (mm)170
Weight (kg)6,3

Logistic Dimensions & Gross Weight

DimensionValue
Length (cm)36,0
Width (cm)34,0
Height (cm)26,0
Gross Weight (kg)7,098
Volume (cdm)31,824

Stock Data

ItemValue
Planned Delivery Time (Days)103

Life Cycle

ItemValue
Sales Start15.02.2017
Predecessor156594 / FR-F740-00170-EC

Additional Product Information

ItemValue
Binding Tariff InformationDEBTI-21865/22-1
BTI validity date01.01.2026
Battery includedNO

Export Data

ItemValue
Commodity Code85371091
Legal Control (Dual Use List)Not Listed
Country of OriginChina (CN)
Preference Status (Supplier Declaration)Non EU

Environmental

ItemValue
REACH Limit ExceededNO
Dangerous Goods ClassNO
Dangerous Goods IdentifierNO
RoHS ComplianceCOMPLIANT
WEEEB2B

Conformity

CertificationStatus
CECOMPLIANT
UL/cULCOMPLIANT
EACNON-COMPLIANT
Shipping ApprovalsDNV,ABS
UKCACOMPLIANT

Documentation & Media Data

Document TypeURL
Manualhttps://emea.mitsubishielectric.com/fa/advanced-search?ct=document&doc-cats=bltdae25c2bd5f2ff94&q=FR-F840-00170-E2-60&doc-lang=en
Certificateshttps://emea.mitsubishielectric.com/fa/advanced-search?ct=document&doc-cats=blt8050dd1408c11cc2&q=FR-F840-00170-E2-60&doc-lang=en
CADhttps://emea.mitsubishielectric.com/fa/advanced-search?ct=document&doc-cats=blt26ecc97a31a841c1&q=FR-F840-00170-E2-60&doc-lang=en
Network configuration filehttps://emea.mitsubishielectric.com/fa/advanced-search?ct=document&doc-cats=blte8cf990c7c524b4e&q=FR-F840-00170-E2-60&doc-lang=en

Product Packaging

MaterialWeight (g)
Cardboard677
Other paper0
Aluminum0
Steel0
Styrofoam195
Other plastic6,768
Wood0
Glass0
Others0

Spare Parts

MaterialDescriptionQuantityUnit
282883FR-A840-00170-2-60 PCB MA1PC

Compatible Products

MaterialDescription / Price List Text / Classification
70727FR-A5 CBL 1
Cable for connecting Inverter and Programming panel; 1m
Class 100100405: FA-Inverter: Cable
70728FR-A5 CBL 3
Cable for connecting Inverter and Programming panel; 3m
Class 100100405: FA-Inverter: Cable
70729FR-A5 CBL 5
Cable for connecting Inverter and Programming panel; 5m
Class 100100405: FA-Inverter: Cable
87246FR-BAL-B-7,5K
Input Reactor 3ph; 400V; for 7,5kW
Class 100100406: FA-Inverter: Choke
88426SC-FR-PC CONNECTION CABLE PC>INVERTER
Programming Cable RS 232>RS485/422; 5m
Class 100100405: FA-Inverter: Cable
127947BU-UFS 22
Brake Unit 400V; Contin. Braking Current 22A; 10sec peak current 34A
Class 100100407: FA-Inverter: Brake Option
157515FR-ADP
Adaptor Module for Operator Panel FR-DU07
Class 100100403: FA-Inverter: External Option
167612FR-RJ45-HUB10
Distribution Module for RJ45; 10 way
Class 100100403: FA-Inverter: External Option
167613FR-RJ45-HUB4
Distribution Module for RJ45; 4 way
Class 100100403: FA-Inverter: External Option
167614FR-RJ45-TR
Terminal Resistor Plug RJ45
Class 100100403: FA-Inverter: External Option
193678FFR-BS-00250-30A-SF100
Radio Noise Filter for FR-A&F-00170/00250-EC; C1 20m; C2 100m
Class 100100404: FA-Inverter: Filter
209737FFR-SI-18A-SS1
Sinusfilter for 200/230/400V Inverters;max. 18A;FT=4-16kHz;(W*H*D) 190*230*120mm
Class 100100404: FA-Inverter: Filter
209756FFR-DT-25A-SS1
du/dt Filter for 400V Inverters; max. 25A; FT=2-16kHz; (W*H*D) 125*140*80mm
Class 100100404: FA-Inverter: Filter
221540USB-CAB-5M
USB 2.0 connection cabel, plug USB A to plug USB B (mini), 5m
Class 100100303: FA-HMI: Cable
238348FFR-HEL-H7.5K-E
DC Link choke for 400V Inverter; 7,5kW; 3,55mH; 14A
Class 100100406: FA-Inverter: Choke
247894BH-D10 3P 32A TYPE C N
Miniature circuit breaker 32 A, 3 pole, Type C
Class 100100801: FA-MCB: Miniature Circuit Breaker
254689NF32-SV 3P 30A
Circuit breaker 3pole. In = 30A; Icu = Ics = 2,5kA at AC 440V
Class 100100901: FA-MCCB: Moulded-Case Circuit Breaker
254689NF32-SV 3P 30A
Circuit breaker 3pole. In = 30A; Icu = Ics = 2,5kA at AC 440V
Class 100100901: FA-MCCB: Moulded-Case Circuit Breaker
254783NF63-HV 3P 30A
Circuit breaker 3pole. In = 30A; Icu / Ics = 10 / 8kA at AC 440V
Class 100100901: FA-MCCB: Moulded-Case Circuit Breaker
254783NF63-HV 3P 30A
Circuit breaker 3pole. In = 30A; Icu / Ics = 10 / 8kA at AC 440V
Class 100100901: FA-MCCB: Moulded-Case Circuit Breaker
262948A8NDPV1
Profibus DPV1 with Dsub Interface for FR-A/F800
Class 100100402: FA-Inverter: Internal Option
262949A8NPRT_2P
Profinet 2port Interface for FR-A/F800 with Drive Profile
Class 100100402: FA-Inverter: Internal Option
262950A8NEIP_2P
EtherNet/IP 2port Interface for FR-A/F800
Class 100100402: FA-Inverter: Internal Option
269402NF63-SV 3P 30A
Circuit breaker 3pole. In = 30A; Icu = Ics = 7,5kA at AC 440V
Class 100100901: FA-MCCB: Moulded-Case Circuit Breaker
269402NF63-SV 3P 30A
Circuit breaker 3pole. In = 30A; Icu = Ics = 7,5kA at AC 440V
Class 100100901: FA-MCCB: Moulded-Case Circuit Breaker
269426FR-A8AX
16-Bit-Digital-Input; BCD/Binary-Code; 24V DC; 5mA for FR-F/A800
Class 100100402: FA-Inverter: Internal Option
269427FR-A8AY
Digital-/Analog Output; Output load: 24V DC; 0,1A for FR-F/A800
Class 100100402: FA-Inverter: Internal Option
269428FR-A8AR
Relay output; 3 additional output relays for FR-A/F800
Class 100100402: FA-Inverter: Internal Option
269431FR-A8NC
CC-Link Interface for FR-A/F800
Class 100100402: FA-Inverter: Internal Option
269431FR-A8NC
CC-Link Interface for FR-A/F800
Class 100100402: FA-Inverter: Internal Option
269432FR-A8ND
DeviceNet Interface for FR-A/F800
Class 100100402: FA-Inverter: Internal Option
270286FR-HC2-H7.5K KIT
Harmonic Converter 7,5 kW for Power Factor correction; 400V Class; KIT
Class 100100403: FA-Inverter: External Option
273102FR-A8NCE
CC-Link IE Field Interface for FR-A/F800
Class 100100402: FA-Inverter: Internal Option
274514FR-A8NP
Profibus DP Interface for FR-A/F800 with FR-A/F700 PPO types
Class 100100402: FA-Inverter: Internal Option
274526FR-A8TAT
Adapter for control terminal of A/F700 to A/F800
Class 100100402: FA-Inverter: Internal Option
275503FR Configurator-M+FR-Configurator2
FR-Configurator for 700 series; multi l + FR-Configurator2 for 800 series
Class 100101203: FA-Software: Software Inverter
277881FR-A8CN02
Heatsink Protrusion Attachment for FR-F/A840-00170/00250; for FR-A820-00340/0049
Class 100100403: FA-Inverter: External Option
279239S-T21 AC24V 2A2B
Magnetic contactor. 11kW; 2NO + 2NC; Us = AC 24V, 50Hz
Class 100101001: FA-MC: Magnetic Contactor
279239S-T21 AC24V 2A2B
Magnetic contactor. 11kW; 2NO + 2NC; Us = AC 24V, 50Hz
Class 100101001: FA-MC: Magnetic Contactor
279241S-T21 AC100V 2A2B
Magnetic contactor. 11kW; 2NO + 2NC; Us = AC 100V, 50Hz
Class 100101001: FA-MC: Magnetic Contactor
279241S-T21 AC100V 2A2B
Magnetic contactor. 11kW; 2NO + 2NC; Us = AC 100V, 50Hz
Class 100101001: FA-MC: Magnetic Contactor
279242S-T21 AC200V 2A2B
Magnetic contactor. 11kW; 2NO + 2NC; Us = AC 200V, 50Hz
Class 100101001: FA-MC: Magnetic Contactor
279242S-T21 AC200V 2A2B
Magnetic contactor. 11kW; 2NO + 2NC; Us = AC 200V, 50Hz
Class 100101001: FA-MC: Magnetic Contactor
279244S-T21 AC400V 2A2B
Magnetic contactor. 11kW; 2NO + 2NC; Us = AC 400V, 50Hz
Class 100101001: FA-MC: Magnetic Contactor
279244S-T21 AC400V 2A2B
Magnetic contactor. 11kW; 2NO + 2NC; Us = AC 400V, 50Hz
Class 100101001: FA-MC: Magnetic Contactor
283940FR-A8AZ
Analog Input/ output, Thermistor interface
Class 100100402: FA-Inverter: Internal Option
284809A8NECT_2P
Ethercat 2port Interface for FR-A/F800
Class 100100402: FA-Inverter: Internal Option
288438MMP-T32LF 18A
Motor prot. switch. 7,9kW; Ir=12,0 ~ 18,0A; Icu AC 400V=15kA
Class 100101101: FA-MMS: Manual Motor Starter
290115FR-A8NCN
Control Net Interface for FR-A800 series
Class 100100402: FA-Inverter: Internal Option
290116FR-A8TR
Screw Terminal Block for FR-A/F800
Class 100100402: FA-Inverter: Internal Option
291922BHW-T10 3P Type B 32A
MCB 3-pole, Rated current 32A, Operating characteristic B
Class 100100801: FA-MCB: Miniature Circuit Breaker
291994BHW-T10 3P Type C 32A
MCB 3-pole, Rated current 32A, Operating characteristic C
Class 100100801: FA-MCB: Miniature Circuit Breaker
292084BHW-T10 3P Type D 32A
MCB 3-pole, Rated current 32A, Operating characteristic D
Class 100100801: FA-MCB: Miniature Circuit Breaker
294939FR-D-Sub9-A8NP-01
D-Sub9 Connection Adapter for FR-A8NP + Cover
Class 100100402: FA-Inverter: Internal Option
296613FR-LU08-01
Clear text LCD Parameter unit for all units of 800 Series (IP55)
Class 100100403: FA-Inverter: External Option
307170FR-A8ERS-60
Optioncard to change Ethernet board to serial communication
Class 100100402: FA-Inverter: Internal Option
307170FR-A8ERS-60
Optioncard to change Ethernet board to serial communication
Class 100100402: FA-Inverter: Internal Option
307170FR-A8ERS-60
Optioncard to change Ethernet board to serial communication
Class 100100402: FA-Inverter: Internal Option
307170FR-A8ERS-60
Optioncard to change Ethernet board to serial communication
Class 100100402: FA-Inverter: Internal Option
403133FR-A8AVP
Phase detection option board of FR-A/F800
Class 100100402: FA-Inverter: Internal Option
403134FR-A8VPB-H
Phase detection transformer box for FR-A8AVP
Class 100100403: FA-Inverter: External Option
409893FR-XC-H7.5K
Multifunction Regeneration Conv.;400V class;7,5kW
Class 100100403: FA-Inverter: External Option
409914FR-XCL-H7.5K
Standalone reactor for FR-XC regeneration converter;400V;7,5 kW;Common bus reg.
Class 100100403: FA-Inverter: External Option
475731NF32-SVF 3P 30A
Circuit breaker F 3pole. In = 30A; Icu = Ics = 2,5kA at AC 440V
Class 100100901: FA-MCCB: Moulded-Case Circuit Breaker
475731NF32-SVF 3P 30A
Circuit breaker F 3pole. In = 30A; Icu = Ics = 2,5kA at AC 440V
Class 100100901: FA-MCCB: Moulded-Case Circuit Breaker
487882FR-A8NCG
Plug-in Option for CC-Link IE TSN Communication Function
Class 100100402: FA-Inverter: Internal Option
500830FR-XCG-H7.5K
Standalone reactor for FR-XC regeneration converter; 400V class;7,5kW;Reg.mode
Class 100100403: FA-Inverter: External Option
591573RHF-5P 7.5-400-50-20-C
High efficient double-stage passive harmonic filter for THDi <5%;400V;50Hz;7.5kW
Class 100100404: FA-Inverter: Filter
591593RHF-8P 7.5-400-50-20-C
High efficient double-stage passive harmonic filter for THDi <8%;400V;50Hz;7.5kW
Class 100100404: FA-Inverter: Filter
600200MMP-T32 18A
Motor circuit breaker;200-690V; 7.5kW(at 400V);50/60Hz; 12-18A; without UL
Class 100101101: FA-MMS: Manual Motor Starter

PDF preview unavailable. Download the PDF instead.

000000000000307216 20250828 mitsubishi factsheet Adobe LiveCycle Designer 11.0 Adobe XML Form Module Library

Related Documents

Preview Mitsubishi Electric FR-F840-00470-E2-60 Inverter: Material Fact Sheet
Comprehensive material fact sheet detailing the specifications, dimensions, conformity, and compatible accessories for the Mitsubishi Electric FR-F840-00470-E2-60 FA-Inverter.
Preview Mitsubishi Electric FR-F840-00038-E2-60 Inverter: Material Fact Sheet and Specifications
Comprehensive material fact sheet for the Mitsubishi Electric FR-F840-00038-E2-60 FA Inverter. This document provides detailed technical specifications, product dimensions, weight, lifecycle information, export data, conformity details, and a list of compatible accessories for industrial automation applications.
Preview Mitsubishi FR-F840-00250-E2-60 Inverter: Material Fact Sheet
Detailed material fact sheet for the Mitsubishi FR-F840-00250-E2-60 inverter, including technical specifications, dimensions, weight, compatible products, and documentation links.
Preview Mitsubishi Electric FR-F840-00620-E2-60 FA-Inverter: Material Fact Sheet and Specifications
Detailed material fact sheet for the Mitsubishi Electric FR-F840-00620-E2-60 FA-Inverter, including technical specifications, dimensions, weight, lifecycle information, export data, environmental compliance, and a list of spare parts and compatible products.
Preview Mitsubishi Electric FR-F820-01540-E3-60 Inverter Material Fact Sheet
Detailed material fact sheet for the Mitsubishi Electric FR-F820-01540-E3-60 inverter, covering general data, specifications, dimensions, environmental compliance, and compatible accessories.
Preview Mitsubishi Electric FR-F840-00470-E2-60 Inverter Fact Sheet
Technical specifications and product details for the Mitsubishi Electric FR-F840-00470-E2-60 FA Inverter, including general data, dimensions, weight, export information, and compatible products.
Preview Mitsubishi Electric 87249 FR-BAL-B-37K AC Main Supply Choke - Material Fact Sheet
This material fact sheet provides comprehensive details for the Mitsubishi Electric 87249 FR-BAL-B-37K AC Main Supply Choke. It includes product hierarchy, technical specifications such as inductance, rated capacity, and protection class, as well as dimensions, weight, stock information, life cycle data, export details, environmental compliance, and conformity certifications. Manufactured in Germany, this component is designed for industrial automation applications.
Preview Mitsubishi Electric 87245 FR-BAL-B-5,5K AC Main Supply Choke - Material Fact Sheet
Detailed material fact sheet for the Mitsubishi Electric 87245 FR-BAL-B-5,5K AC Main Supply Choke, including technical specifications, dimensions, weight, stock data, and export information.