Instruction Manual for Beyes models including: I120EN, REV5G1924, P9 Ultrasonic Scaler, P9, Ultrasonic Scaler, Scaler
Beyes Dental Handpiece and Equipment
File Info : application/pdf, 11 Pages, 975.89KB
DocumentDocumentComfort-Sonic® Ultrasonic Scaler P9 Instruction for Use Table of Contents 1. The installation and components of equipment 1.1 Introduction ....................................................................................... P3 1.2 Components ...................................................................................... P3 1.3 The main technical specifications...................................................... P3 1.4 Installation of the main components .................................................. P4-6 2. Product function and operation 2.1 scaling funtion.................................................................................... P7-8 2.2 Auto-water supply function ................................................................ P9 2.3 Endo function..................................................................................... P9-10 3. Sterilization and maintenance 3.1 Sterilization of detachable handpiece................................................ P10 3.2 Sterilization of scaling tips and endochuck........................................ P10 3.3 Serilization of torque wrench and edo wrench................................... P10 3.4 Cleaning of tips, endochuck, torque wrench and endo wrench ......... P10-13 3.5 Troubleshooting and notes ................................................................ P10-13 4. Precaution 4.1 Notice when using equipment ........................................................... P13 4.2 Contraindication................................................................................. P13-14 4.3 Storage and maintenance ................................................................. P14 4.4 Transportation ................................................................................... P14 4.5 Working condition .............................................................................. P14 5. After service.................................................................................... P14 6. Symbol instruction ....................................................................... P15 7. Environmental Protection........................................................... P16 8. Manufactrurer's rights ................................................................. P16 9. For technical data, please contact ........................................... P16 10. Declaration of conformity 10.1 Product conformity the following standards..................................... P16 10.2 Declaration of conformity................................................................. P16-19 2 1. The installation and components of equipment 1.1 Introduction Beyes Dental Canada Inc. Is a professional manufacturer in researching , developing and producing ultrasonic piezo scalers. This product is mainly used for teeth cleaning and is also an indispensable equipment for tooth disease preventions and treatments. The new product COMFORT-SONIC ultrasonic piezo scaler has scaling, perio, endo and auto-water supply functions. It contains the following features: 1.1.1. Aith auto-water supply function, easier operation 1.1.2. The inner water pipe is made from antisepic materials, clinical fluids, such as Hydrogen peroxide, chlorhexidine and sodium hypochlorite, etc, can be suited perfectly under the mode of auto-water supply system so that the performance of perio and endo is improved dramatically. 1.1.3. The handpiece is detachable and can be autoclaved to the temperature of the 135OC and the pressure of 0.22Mpa. 1.1.4. Automatic frequency tracking ensures that the machine always works on the best frequency and it also performs steadily. 1.1.5. Controlled by PC, easy operation and more efficient for scaling. These features make COMFORT-SONIC become a new generation product in the world dental market. 1.2 Components 1.2.1. (The components of the machine are listed in the packing list) The scaling tips and their accessories are not listed in this instruction manual completely. The detail can be found in the instruction for tips and packing list attached to the machine. 1.2.2. Product performance and structure Ultrasonic piezo scaler is composed of electro circuit, water way and ultrasonic transducer. 1.2.3. Scope of application Ultrasonic piezo scaler COMFORT-SONIC is used for the dental calculus elimination and root canal treatment. 1.3 The main technical specifications · Adapter Input: 100V to 240V~ 50Hz/60Hz 1.2A (Max) · Main unit input: 30VDC 1.3A · Output primary tip Vibration excursion: 100m · Output half-excursion force: < 2N · Output tip vibration frequency: 28kHz ±3kHz · Output power: 3W to 20W · Main unit fuse: 250VT 1.6AL · Adapter fuse: 250VT 2.0AL · Water pressure: 0.1bar to 5bar(0.01Mpa to 0.5 Mpa) 3 · Weight of main unit: 1.35kg · Weight of adapter: 0.3kg · Operating mode : Continuous operation · Type of protection against electric shock: Class: equipment · Degree of protection againest electric shock: Type BF applied part · Degree of protection against harmful ingress of water : Ordinary equipment(IPX0) Protection degree against water(used on the foot switch):IPX1 · Degree of safety of application in the presence of a Flammable Anesthetic Mixture with air or with Oxygen or Nitrous Oxide: Equipment is not suitable for being used in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide. 1.4 Installation of the main components 1.4.1.Installation and conection. a) The front of the main unit b) The back of the main unit c) Connection of foot switch, adapter and main unit 4 5 d) Water bottle installation e) Connection of detachable handpiece 6 f) Installation of tip and endochuck with wrench 2. Product function and operation 2.1 Scaling funtion 2.1.1 Operation · Open the packaging box, make sure that all the parts and accessories are completed according to the packing list. Take the main unit out of the box and put it on a stable place. · Turn the water control knob to the maximum based on symbols as shown in 3.5.2[note 1] · Insert the plug of the foot switch to its socket (See Figure 3). · Water line installation: * Auto-water supply Install the bottle reverely to the connector with adequate purified water (see figure 5) *Outside water Connect one end of the water pipe to the water entrance , and the other end to the purified water source (see figure 4) · Screw the scaling tip tightly to the handpiece by torque wrench, then connect the handpiece and the connector of cable correctly. · Insert the plug of the power source to its socket, then get through to the power (see figure 3) · Switch on the main unit , then the scaling indicator, the first five power indicators & auto-water indicator will be lighted on. · According to needs, push the water button to choose auto-water or outside-water. Then the indicator of chosen mode will be lighted on. · Select a suitable scaling tip as you need, screw it on the handpiece tightly by the torque wrench(see figure 7) 7 · The normal frequency is extremely high. Under the normal working state of scaling tips, a light touch and a certain to-and-fro motion will elimianate the tartar without heating. Overexertion and long-time lingering are forbidden. · Vibrating intensity: Adjust the vibration intensity as you need, generally turn the knob to the middle grade. According to patient's different sensitivity and the rigidity of the gingival tartar, adjust the vibration intensity during the clinical treatment. · Water volume adjust: Step on the foot switch, and the tip will begin to vibrate, then turn the water control switch to form fine spray to cool down the handpiece and clean the teeth. · The handpiece can be handled in the same gesture as a pen in hand. · After finishing operation, keep the machine working for 30 seconds on the water supply condition in order to clean the handpiece and the scaling tip. · Unscrew the scaling tip and pull out handpiece, then sterilize them. Notice Don't pull the handpiece out when the foot switch is stepped on and the ultrasonic vibration is produced from the machine. 2.1.2 Instruction for main components of detachable handpiece(see figure 6): · Nipple: The nipple can be removed. You can screw out the nipple and clean the pole with alcohol termly. · Handpiece seal: The seal can't be removed. · Handpiece: The main part of the whole handpiece, can be autoclaved under the high temperature and pressure. · The connector of the cable: Connect the handpiece with the water source and power supply of the main unit. Notice Keep dry when the detachable handpiece connects to the connector of the cable. 2.1.3 Instruction of torque wrench(see figure 7) · The torque wrench's structure is designed in special way which can control the strength of the scaling tip's installation properly and correctly. It also can guarantee the operator screw or unscrew the scaling tip effectively and keep their hands away from being scratched. · Operation a. Take the scaling tip into the torque wrench as showed in figure 7. b. Tip installation: Hold the handpiece, turn the tip toward direction as showed in figure 7 with the torque wrench. Turn twice more circles when the tip stops, then the tip will be installed. c. Tip's uninstallation: Hold the handpiece, turn the wrench in anti-clockwise direction direction. d. Serilize it in sterilizer after each treatment. e. The torque wrench must be cooled down naturally after sterilization to avoid scald when using for the next time. f. Keep the torque wrench in a cool, dry and ventilated place and keep it clean. 8 2.2 Auto-water supply function 2.2.1. Usage process · Pull out the water bottle verivally. · Open the lid, fill the bottle with adequate purified water and then tighten the lid. · Clean the joint and interface of water bottle. · Put and place the bottle with water upside down, insert the joint into the interface vertically. (see figure 5). · Press "WATER" to choose auto-water supply. 2.2.2. Notice · Make sure the air hole and water entrance are not blocked. (see figure 8) · Check if the cushion inside the lid is in a good condition. If it becomes deformed or it falls off, reinstall it or change to a new one. · Tighten the lid. · Clean the joint and interface of water bottle before each clinical operation. · After every clinical operation with clinical liquid, change a bottle with purified water, turn the water supply to maximum, allow the machine to work with auto-water supply for 30 seconds in order to keep the water line and spare parts clean and durable. · When the water is lower than water level lower limit, add more water to keep water pipe smooth. (see figure 9) 2.3 Endo function 2.3.1. Usage process · Fix endochuck to handpiece by endo wrench (see figure 7) · Unscrew the screw cap on the endochuck. · Put the ultrasonic file into the hole in the front of endochuck. · Screw down the screw cap with endo wrench to tight up the ultrasonic file. · When ultrasonic scaler turns into endo function, only the first lead light will be on and the power will be at the 1st grade. Put the ultrasonic file into the patient's root canal slowly, step on the foot switch, during the treatment, turn up the power gradually according to the needs. 2.3.2 Notice · When fixing endochuck, it must be screwed down. · The screw cap on the endochuck must be screwed down. 9 · Don't press it too much when the ultrasonic file is in root canal. · Don's step on the foot switch until the ultrasonic file is in root canal. · The power ranged from the 1st to the 5th grades. 3. Sterilization and maintenance 3.1 Sterilization of detachable handpiece 3.1.1 Autoclaved in high temperature/pressure: · 121OC/1bar (0.1 Mpa) · 135OC/2.2 bar (0.22Mpa) · Pull out the handpiece and unscrew scaling tip and ensochuck after each operation. · Pack the handpiece with sterile gauze or sterile bag before steriziling. · Reuse handpiece after it cools naturally in case of scalding hand. 3.1.2 Notice · Dry the cleaning liquid in the handpiece with compressed air before sterilization. · Ensure that the scaling tip has been unscrewed from the handpiece and it could not be sterilized with others. · Please notice whether the outer part of the handpiece is damaged during the treatment or sterilization, don't smear any protective oil on the surface of handpiece. · There are two waterproof "o" rings at the end of handpiece. Please lubricate them with dental lube frequently, as sterilization and repeated pulling and inserting will reduce their life. Change a new one onece it is damaged or worn excessively. · The following sterilizing methods are forbiden: Putting handpiece into any liquid for boiling. Dipping handpiece in disinfectors such as iodine, alcohol and glutaraldeyde. Sterilizing handpiece into oven or microwave oven for baking. 3.2 Sterilization of scaling tips and endochuck. All the scaling tips and endochuck can be autoclaved under higt temperature and pressure. 3.3 Sterilization of torque wrench and edo wrench · The torque wrench and endo wrench can be sterilized in high temperature and pressure. · The following sterilization ways for torque wrench are forbiden: Baise in liquor. Dipping in iodine, alcohol or glutaradehyde. Sterilizing in oven or microwave oven. Notice We are not responsible for any damage of the torque wrench directly or indirectly made by any ways which indicated in 3.1e and 3.3b. 3.4 Cleaning of tips, endochuck, torque wrench and endo wrench The scaling tip, endochuck, torque wrench and endo wrench can be cleaned by ultrasonic cleaner. 10 3.5 Troubleshooting and notes 3.5.1 Troubleshooting Fault The scanling tip doesn't vibrate and there is no water flowing out when stepping on the foot switch The scaling tip doesn't vibrate Possible cause The power pipe plug is in loosen contact The foot switch is in loosen contact The fuse in the main unit is broken The tip is in loosen contact There is water flowing out when stepping on the foot switch Something wrong with the handpiece Something wrong with the cable The scaling tip vibrates but there is no spray when stepping on the foot switch The water control switch is not on There is impurity in the electricmagnetic valve The watere system is blocked There is still water flowing out after the power is off The handpiece generates heat The amount of spouting water is too little There is impurity in the electricmagnetic valve The water control switch is in a low setting The water pressure is not high enough The water pipe is blocked The vibration of tip becomes weak The tip hasn't been screwed on to the handpiece tightly The tip is loosen because of vibration The coupling between the handpiece and the cable isn't dry Soulutions Make the pulg insert to the socket well Insert the foot switch to its socket tightly Contact our dealers or us Screw the tip on the handpice tightly (see figure7) Send the handpice to our company to repair Contact our dealer or us Turn on the water control switch [note 1] Contact our dealers or us Clean the water pipe by multifunction syringe[note 2] Contact our dealers or us Turn the water control switch to a higher grade[note2] Make the water pressure higher Clean the water pipe by multifunction syringe[note2] Screw the tip on the handpiece tightly(see figure7) Screw on the tip tightly(see figure7) Dry it by the hot air The tip is damaged[note 3] Change to a new tip There is water seeping from the coupling between the handpiece and the cable The ultrasonic doesn't vibrate There is noise coming from the endochuck Peristaltic leak There is no water coming out from the handpiece(automatic water supply mode) The waterproof "O" ring is damaged The screw is loosen Endochuck is damaged The screw is loosen The inner water pipe cracks There is air in the water pipe Change to a new "O" ring Tighten it Change to a new endochunck Tighten it Replace a new peristaltic pump Turn the water control to the Max, reinsert the bottle. 11 If the problem still can't be solved, please contact with local dealer or manufacturer. 3.5.2 Notes · [Note1] Turn the water control switch toward direction showed in symobol till not be able to turn anymore, it comes to the min, on the contrary direction, the water volume increases. · [Note2] Clean the water pipe with the Multi-function syringe of the dental unit (see figure 10) a. Cut the water pipe from a distance of 10cm to 20cm from the water entrance. b. Turn on the electricity and get through to the power. c. Connect the multi-function syringe of dental unit to the water pipe. d. Disassemble the tip or handpiece e. Step on the foot switch. f. Turn on the switch of the multi-function syringe, press the water into the machine and the impurity blocked in the water pipe can be eliminated. · [Note3] If the scaling tip is screwed on tightly and there is fine spray too, the following phenomena show that the scaling tip is damaged: a. The vibrating intensity and the water spray degree become weak obviously. b. During treatment, it will produce the sound like "buzz" from the scaling tip. · Note 4. a. Pull out the water bottle vertically. b. Remove the bolt with screwdriver.(see figure 11) c. Pull the two fasten ring out to the right, then pull the peristaltic pipe out to the right. (see figure 12) d. Pull the peristaltic out from the drive pole, and install the new peristaltic back to the same position.(see figure 12) e. Install the fasten rings onto the ends of pipes, then insert the pipes into water-in and water-out joints. Push the fasten rings to mid of water-in and water-out joints. (see figure12) f. Install the lid. · Notice : a. Dry the drive pole to avoid being slippery. b. Install the peristaltic onto the drive pole carefully and lightly to avoid the damage of the inner structure of the machine. c. After changing a new peristaltic, turn water supply to max and allow the machine to work with auto-water supply for 30 seconds in order to be compatible with peristaltic and its pipes. 12 4. Precaution 4.1 Notice when using equipments 4.1.1 Keep the scaler clean before and after operation. 4.1.2 The handpiece, scaling tip, torque wrench, endo wrench and endochuck must be sterilized before each treatment. 4.1.3 Don't screw or unscrew the scaling tip and endochuck when stepping on the foot switch. 4.1.4 The scaling tip must be fastened and there must be fine spray or dripped from the tip when operating. 4.1.5 Change to a new one when the tip and ulrasonic file are damaged or worn excessively. 4.1.6 Don't twist the tip and endo chuck or rub them. 4.1.7 If using the water source without hydraulic pressure, the water surface should be one meter higher than the head of patient. 4.1.8 Ensure the connector of handpiece and the socket of the cable are dry before installing the handpiece. 4.1.9 Don't pull the cable forcibly in case of the handpeice falling off the cable. 4.1.10 Don't' knock or rub the handpiece. 4.1.11 After operating, turn of the power, then pull out the plug. 4.1.12 We are only responsible for the safety on the following conditions: · The maintenance, repairment and modification are made by the manufacturer or the the authorized dealer. · The changed components are originated of "BEYES" and are operated according to instruction manual. 4.1.13 The internal screw thread of the scaling tips produced by some maunactures is coarse, rusty and collapsed. This will damage the external screw thread of the handpiece irretrievably. Please use "BEYES" brand scaling tips. 4.1.14 This model only matches the adapter of our company. 4.1.15 Keep peristaltic dry. Otherwise, its wheels will be likely to be slippery and the water supply will not work. 4.1.16 Clinical fluids are forbidden when the machine connects outside water source to avoid rustiness of the metal part inside machine. 4.2 Contraindication 4.2.1 The hemophilia disease patient is not allowed to use this equipment. 13 4.2.2 The patients or doctors with heart pacemaker are forbidden to use this equipment. 4.2.3 The patient with heart disease, pregnant women and children should be cautious with using the equipment. 4.3 Storage and maintenance 4.3.1 The equipment should be handled carfully and lightly. Be sure that it is far from the vibration , and install or keep in a cool, dry and ventilated place. 4.3.2 Don't store the machine together with the articles that are combustible, poisonous, caustic, and explosive. 4.3.3 This equipment should be stored in a room where th e relative humidity is 80%, atmospheric pressure is 50kPa to 106kPa, and the temperature is -10OC to 50OC. 4.3.4 If it is has not been used a long time, please ensure the machine gets through to the power and water once per month for five minutes. 4.4 Transportation 4.4.1 Excessive impact and shake should be prevented in transportation. Lay it carefully and lightly and don't invert it. 4.4.2 Don't put it together with dangerous goods during transportation. 4.4.3 Avoid solarization and getting wet in rain and snow during transportation. 4.5 Working condition a) Enironment temperature:5O0C to 40O0C b) Relative humidity: 80% c) Atmosphere pressure: 70kPa to 106kPa 5. After service We offer one year's free repair to the equipment according to the warranty card. The repair of the equipment should be carried out by our professional technicians. We are not responsible for any irretrievable damage caused by the non-professional person. 6. Symbol instruction EN ISO 9001:2008 Certificated by ISO international quality control system EN ISO 13485:2003+AC:2007 Certificated ISO by medical instrument manufacturer quality control system. 14 15 7. Environmental Protection There is no harmful factor in our product. You can deal with it based on the local law. 8. Manufactrurer's rights We reserve the rights to change the design of the equipment, the technique, fittings, the instruction manual and the content of the original packing list at any time without notice. If there are some differences between blueprint and real equipment, take the real equipment as the norm. 9. Please contact us for more information 10. Declaration of conformity 10.1 Product conformity the following standards. EN ISO 14971:2000+A1:2003 EN 980:2003/ ISO 9687:1993 / EN 1041:1998 EN 60601-1:1990+A1:1993+A2:1995+A13:1996 EN 60601-1-4:2001 * EN 60601-1-2: 2001 +A1:2006 EN ISO 7405:1997 EN ISO 10993-1:2003 / EN ISO 10993-5:1999 EN ISO 10993-10:2003+A1:2003 EN 61205:1994 / EN ISO 22374:2005 EN ISO 17664:2004 / EN ISO 17665-1:2006 10.2 EMC-Declaration of conformity Guidance & Declaration electromagnetic immunity The model COMFORT-SONIC is intended for using in the electromagnetic environment specified below. The customer or the user of the model COMFORT-SONIC should assure that it is used in such an environment. Emissions test Compliance Electromagnetic environment- guideance RF emissions CISPR 11 Group 1 The model COMFORT-SONIC uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emission CISPR 11 Harmonic emissions IEC610003-2 Voltage fluctuations/ flicker emissions 1EC61000-3-3 Class B Class A Not applicable The model COMFORT-SONIC is suitable for used in domestic establishment and in establishment directly connected to a alow voltage power supply network which supplies buildings used for domestic purposes. 16 Guidance & Declaration electromagnetic immunity The model COMFORT-SONIC is intended for using in the electromagnetic environment specified below. The customer or the user of the model COMFORT-SONIC should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic discharge (ESD) IEC 61000-4-2 ±6kV contact ±8kV air ±6kV contact ±8kV air Floors should be wood, concrete or ceramic tile. If floors are coverd with synthetic material, the realative Electrical fast transient/burst IEC 61000-4-4 Surge IEC61000-4-5 Voltage dips, short interruptions and voltage variations on power supply input lines IEC61000-4-11 Power frequency (50/60 Hz) magnetic field IEC61000-4-8 ±2kV for power supply lines ±1kV for Input/output lines ±1kV differntial mode , ±2kV common mode <5% UT(>95% dip in UT.) For 0.5 cycle 40% UT (60% dip in UT) For 5 cycles 70% UT (30% dip in UT) For 25 cycles <5% UT (>95% dip in UT) For 5sec ±2kV for power supply lines ±2kV common mode <5% UT(>95% dip in UT.) For 0.5 cycle 40% UT (60% dip in UT) For 5 cycles 70% UT (30% dip in UT) For 25 cycles <5% UT (>95% dip in UT) For 5sec humidity should be at least 30% Mains power quality should be that of a typical commercial or hospital environment. Mains power quality should be that of a typical commercial or hospital environment. Mains power quality should be that of a typical commercial or hospital environment. If the user of the model COMFORT-SONIC requires continued operaton during power mains interruptions, it is recommended that the model COMFORT-SONIC should be powered from an uninterruptible power supply or a battery. 3A/m Not applicable Not applicable NOTE UT is the a.c mains voltage prior to application of the test level. Guidance & Declaration electromagnetic immunity The model COMFORT-SONIC is intended for using in the electromagnetic environment specified below. The customer or the user of the model COMFORT-SONIC should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Conducted RF IEC61000-4-6 Radiated RF IEC61000-4-3 150kHz to 80MHz 3Vrms 80 MHz to 2.5 GHz 3v 3V/m Portable and mobile RF communications equipment should be used no closer to any part of the model COMFORT-SONIC , including cables, than the recommeded separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance 3V 3V/m d= 1.2×P1/280MHz to 800MHz d= 2.3×P1/2800MHz to 2.5GHz where P is the maximum output power rating of the 17 transmitter in watts(W) according to the transmitter manufacture and is the recommeded separation distance in meters(m). field strengths from fixed RF transmitters, as determined by and electromagnetic site survey, should be less than the compliance level in each frequency range. Interference may occur In the vivinity of equipment marked with the following symbol: NOTE 1 At 80 MHz end 800 MHz. The higher frequency range applies. NOTE 2 There guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. Field strengths from fixed transmitters, such as base stations for radio(cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast connot be transmitters, and electromagnetic site survey should be considered. If the measured field strength in the location in which the model COMFORT-SONIC is used exceeds the applicable Rf compliance level above, the model COMFORTSONIC should be observed to verify normal operation. If abnormal performance is obeserved, additional measures may be necessary, such as reorienting or relocating the model COMFORT-SONIC. Over the frequency range 150kHz to 80MHz, field strengths should be less than 3V/m. Recommeded separation distances between portable and mobile RF communications equipment and the model COMFORT-SONIC The model COMFORT-SONIC is intended for using in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the model COMFORT-SONIC can be help prevent electromagnetic interfernce by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the model COMFORT-SONIC as recommeded below, according to the maximum output power of the communications equipment. Rated maximum output power of transmitter W Spearation distance according to frequency of transmitter m 150kHz to 80MHz d= 1.2×P1/2 80MHz to 800MHz d= 1.2×P1/2 800MHz to 2.5GHz d= 2.3×P1/2 0.01 0.12 0.12 0.23 0.1 0.38 0.38 0.73 1 1.2 1.2 2.3 10 3.8 3.8 7.3 100 12 12 23 For transmitters rated at a maximum output power not listed above, the recommeded separation distance d in metters(m) can be estimated using the equation applicable to the frequency of the transmitter, wheare P is the maximum output power rating of the transmitter in watts (W) accordable to the transmitter manufacture. NOTE 1 At 80MHz and 800MHz. The separation distance for the higher frequency range applies. NOTE 2 There guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. The device has been tested and homologated in accordance with EN 60601-1-2 for EMC. This does not guarantee in any way that this device will not be effected by electromagntic interference. Avoid using the device in high electromagnetic environment. All rights of modifying the product are reserved to the manufacturer without further notice. The picture are only for references. The final interpretation rights belong to BEYES DENTAL CANADA INC. WARRANTY Beyes Dental Canada Inc. hereby warrants that for a period of one (1) year from the date of purchases, this instrument shall be free from defects in material and workmanship and will perform satisfactorily under normal use and service. Users MUST complete the online Warranty Registration Form within 30 days of the purchase date at www.beyes.ca in order to qualify the warranty. If multiple units are purchased, fill out one registration form per unit. Please keep your dealer invoice. A copy of the invoice will be required should warranty service be required. In the event of a breach of this warranty, Beyes liability is limited to, at Beyes option, to replace the defective product or part thereof, or reimbursement of the actual cost of the defective product. In order to take advantage of this limited warranty, the defective product must be returned to Beyes Dental Canada Inc. In no events shall Beyes be liable for any indirect, incidental, or consequential damages. Beyes Canada warrants this product will be free from defects in material and manufacture. Beyes Dental Canada Inc. MAKES NO OTHER WARRANTIES ACTUAL OR IMPLIED. User is responsible for determining the suitability of the product for user's application. If this product is defective within the warranty period, your exclusive remedy and Beyes Dental Canada Inc.'s sole obligation shall be to the repair or the replacement of the Beyes products. 18 19 ! Federal law restricts this device to sale by or on the order of a dentist, physician, or any other practitioner licensed by the law of the states in which he or she practices to use or order the use of this device. Beyes Dental Canada Inc. 23-595 Middlefield Road Scarborough, ON M1V3S2 Canada Tel: 1-855-603-1888 Fax: 1-855-720-1228 Email: info@beyes.ca Web: www.beyes.ca Lotus NL B.V. Koningin Julianaplein 10, Ie Verd, 2595AA, The Hague, Netherlands 0197 I120EN.REV5G1924 Rev.5/09.12.24