Instruction Manual for BEOK models including: TR33, Large LCD Screen Smart Thermostat, TR33 Large LCD Screen Smart Thermostat
Large LCD Screen Smart Thermostat Parameter Supply voltage Power consumption Temp. setting range Floor limited range Temp. Dif. Ambient temperature
Mounting Steps The thermostat adopt pre-guide and limited snap-fit design. It is easy to mount. 3)Mount backing plate into wall-cassette, put screws and then fix thermostat.
File Info : application/pdf, 2 Pages, 1.63MB
DocumentDocumentLarge LCD Screen Smart Thermostat Customized exclusive temperature plan - up to 6 events allowed to set per day Sail shape design-delicate and elegant Large LCD screen-better user experience 485 modbus and room card linkage - customized equipment (optional) Parameter Supply voltage Power consumption Temp. setting range Floor limited range Temp. Dif. Ambient temperature Protection level Shell material AC100~240V; 50/60Hz 1W Max (Wi-Fi 3W Max) 5~9541~99 20~9068~99 0.5~101~10, Factory setting ±1 -5~5023~122 IP20 Anti-Flammable PC Version:TR33 1.5(12/2021) Product Overview This series of thermostat has Floor Heating, Fan Coil, and Integrated version, meeting the requirements under different scenarios. Version System mode Model Application Floor heating Floor heating EP WP WPB AC2 Built-in & floor sensor, floor limit sensor + Weekly programming A NC/NO dual-output + Weekly programming A NC/NO dual-output + Weekly programming+ Potential-free output Timer task + 2-pipe system Fan Coil Heating /Cooling / Ventilation AC2-485 Timer task + 2-pipe system + Potential-free output + Room 485Modbus (optional) + card (optional) AC4 Timer task + 4-pipe system + 485Modbus (optional) + Potential-free output + Room card (optional) Heating / Cooling / Floor heating & fan coil, weekly programming + Integrated Ventilation/Floor heating / AWY Potential-free output + Timer task + Floor heating + Heating 485Modbus (optional) + Room card (optional) Display Symbols Setting temp. Time Display Wi-Fi Timer Task Temporary Mode Manual Mode Auto Mode ECO Mode ECO Child-lock Frost Protection Room Temp. Floor Heating Heating Week Display Wake up; Event 1 Leave (am); Event 2 Return (am); Event 3 Leave (pm); Event 4 Return (pm); Event 5 Sleep; Event 6 Fan Speed Display Room Temp. Floor Temp. Cooling on Heating on Ventilation Cooling Power on/off Fan(Integrated) ECO(Floor heating) Mode Temperature Control Mode(Floor Heating/Integrated) Down Up Auto Mode Weekly-circled programme, up to 6 heating events can be set per day. Heating events, workdays and temperature can be separately customized based on personal routines. Manual Mode Thermostat works based on manually-set temperature, disconnecting from auto mode. Temporary Mode Thermostat works based on manually-set temperature temporarily and then shifts back to auto mode till next event. User Operation Power on/off : Press " " shortly to turn on/off the thermostat. Auto-mode : Press " " for 3 seconds to edit auto-mode settings. (Floor Heating/Integrated) Timer task: Press " " for 3 seconds to edit timer task. (Integrated) Time setting: Press " " for 3 seconds to set time. (Floor Heating) Press " " twice for 3 seconds to set time. (Automatic time synch for Wi-Fi version) Temp setting: Press " " or " " shortly to change setting temperature by 0.5°C. Child-lock: Press " " + " " for 3 seconds to activate child-lock. System mode: Press " " shortly to switch cooling/heating/ventilation (Fan Coil/Integrated) Press " " shortly to switch cooling/heating/ventilation/floor heating/floor heating + heating. (Integrated) Temp control mode: Press " " shortly to switch manual/auto mode. (Floor heating) Press " " shortly to switch manual/auto mode. (Integrated, floor heating) Fan speed setting: Press " " shortly to adjust fan speed.(Integrated) ECO mode: Press" "shortly to set to ECO mode 18°C(65°F). (Floor heating) Auto-mode Setting (Floor Heating/Integrated) Press " " for 3 seconds to edit auto-mode setting. Events Time Symbols Default value Modify Temperature Default value Modify 1 2 Workdays 3 4 5 6 1 Weekends 2 06:00 08:00 11:30 12:30 17:00 22:00 08:00 22:00 Press " " or " " 20(68) 15(59) 15(59) 15(59) 22(72) 15(59) 20(68) 15(59) Press " " or " " Advanced Setting (Usually for Professional Technicians) Under power-off, press " " for 3 seconds to enter advanced setting mode, then re-press " " to switch to next mode. Press " " to save and exit advanced setting mode. Code Meaning " "or" " 00 Postal address(optional) Adjustment range 0x00~0xFA 01 -9.9~9.9(-9~9) 02 0.5~10(1~10) 03 5~95(41~99) 04 5~47(41~99) 05 Frost protection ON: frost protection on OFF: frost protection off 06 / Default Integrated Fan Coil Floor Heating Value 00 AC2-485 AC4 AC2 EP/WP/WPB × -3 ±1 50 5 OFF 07 Sensor selection IN × × 08 Floor limited temp. 20~90(68~99) 35 × × 09 Weekly programming setting 12345: 5/2 week mode 123456: 6/1 week mode 1234567: 7/0 week mode 12345 × × 00: both outputs are normally open 01: main power output is normally Status of potential closed; potential-free output is normally open 10 -free and main power 02: both outputs are normally closed 00 outputs 03: both outputs are normally closed; under power-off, frost protection is off either 11 Delay time of outputs 0~5min 0 × × 00: Child-lock inactivate when screen off; lock all when child-lock activate 01: Child-lock activate when screen off; lock all when child-lock activate 12 Child-lock 02: Child-lock activate when screen off; lock all except Fan Speed, Up and 00 Down when child-lock activate 03: Child-lock activate when screen off; lock all except Power on/off when child-lock activate 00: stay power-off after Power-on-reset 13 Power-on-reset 01: stay power-on after Power-on-reset 02 02: recovery after Power-on-reset 00: turn off room card function 01: set to ECO temp. after pulling room 14 Door card status card out 00 × × 02: stay power-off after pulling room card out 15 Room card heating ECO temp. 10~21(50-69) 18 × × 16 Room card cooling ECO temp. 22~32(72-89) 26 × × 17 Fan coil mode setting 00: Cooling and heating 01: Cooling only 00 × 18 Weekly programming 00: turn on for Integrated 01: turn off 19 Reset Press " "for 3 seconds to reset 01 × × × / Large LCD screen smart thermostat Installation instructions Sensor failure Please select work mode of sensors correctly. When it shows E0/E1 error, thermostat will stay power-off till the error is eliminated.E0: built-in sensor is short-circuited or disconnected. E1: floor sensor is short-circuited or disconnected. Timer Task Setting (Fan Coil / Integrated ) Press " press " " for 3 seconds to enter timer task setting; press " " to change settings; " or " " to adjust parameters; press " " to save and exit. Implement Day Timed power-on/off Task Time 0: No Implement 1: Implement 00: No Effect 01: Take Effect Dimensions (Unit: mm) Floor Heating / Fan Coil #EP #WP #WPB #AC2 13.5 32.6 51 51 Fan Coil / Integrated #AC2-485 #AC4 #AWY 13.5 2 4 64 66 Mounting Steps The thermostat adopt pre-guide and limited snap-fit design. It is easy to mount. 1Release front cover by inserting a head screw-driver into bottom crack. 2Insert the wires and then fix these wires with screws. Suggested wire-stripping length is 7-9mm. 3Mount backing plate into wall-cassette, put screws and then fix thermostat. Make sure that the thermostat is fixed without deformation. Suggested torque is 0.2~0.4N.m (2.0~4. 1kgf.cm). Connecting Diagram The thermostat operates in full capacity in areas with the altitude of less than 2500 above sea level. Power rating of external load should be less than or equal to 80% rated power of the thermostat in areas with altitude of 2500m to 4200m. Floor Heating #TR33-WIF-EP # TR33-EP #TR33-WIFI-WP # TR33-WP #TR33-WIFI-WPB # TR33-WPB L N N1 L1 AC100~240V NTC PC1 PC2 LN AC100~240V Electro thermal actuator or electrical ball valves Potential-free (Potential-free output, for model WPB only) Dry contact signal to control boiler Linkage control; delay time of linkage control is adjustable PC1 PC2 LN AC100~240V Electro thermal actuator or electrical ball valves Potential-free (Potential-free output, for model WPB only) Dry contact signal to control boiler Linkage control; delay time of linkage control is adjustable PC1 PC2 Fan Coil LN Potential-free AC100~240VThree-wire electrical ball valve with two (Potential-free output, for model WPB only) types of control mode Electro thermal actuator or electrical ball valves Dry contact signal to control boiler Linkage control; delay time of linkage control is adjustable L N H M S OPEN CLOSE #TR33-WIFI-AC2 # TR33-AC2 LN AC100~240V N Fan Air conditoner valve N #TR33-WIFI-AC2-485 CLOSE OPEN HI MED LOW L 89 # TR33-AC2-485 N Air conditoner valve L Fan AC100~240V N PC1 PC2 CARD RS RG A B 16 15 14 13 12 11 10 #TR33-WIFI-AC4 # TR33-AC4 NTC 485A 485B Dry contact signal Room card (optional) to control heat pump external sensor(optional) room card linkage(optional) N CLOSE OPEN CLOSE OPEN HI MED LOW L 89 N L Heat valve Cool valve Fan AC100~240V N PC1 PC2 CARD RS RG A B 16 15 14 13 12 11 10 4Re-mount the front cover via snap-fit connection. Integrated #TR33-WIFI-AWY # TR33-AWY NTC 485A 485B Dry contact signal Room card (optional) to control heat pump external sensor(optional) room card linkage(optional) N CLOSE OPEN CLOSE OPEN HI MED LOW L 89 N Floor heating Air conditoner valve valve Fan L AC100~240V N PC1 PC2 CARD RS RG A B Linkage control; delay time of linkage control is adjustable 16 15 14 13 12 11 10 Dry contact signal to control heat pump NTC Room card 485A 485B (optional) room card linkage(optional)