User Manual for EIT models including: Gappscan Heat Exchanger Qualification Surface Integrity Detection System
No part of this User Manual may be reproduced or transmitted in any form, electronic or mechanical, including but not limited to photocopying ... Android is a registered trademark of Google Inc. Bluetooth is a registered trademark of Bluetooth SIG, Inc...
www.eit-international.com What's In the Box IMPORTANT: This is a sensitive instrument and can only be operated by a trained person as certified by EIT International.
www.eit-international.com What’s In the Box IMPORTANT: This is a sensitive instrument and can only be operated by a trained person as certified by EIT International.
File Info : application/pdf, 13 Pages, 1.90MB
DocumentDocumentTM Heat Exchanger Qualification & Surface Integrity Detection System USER MANUAL www.eit-international.com This User Manual contains information that is subject to change. No part of this User Manual may be reproduced or transmitted in any form, electronic or mechanical, including but not limited to photocopying, recording, information retrieval systems, or computer network without the written permission of EIT International. Gappscan and all other EIT International product names are trademarks or registered trademarks of EIT International. Gappscan products may be protected by one or more patents. Windows® is a registered trademark of Microsoft Corporation in the United States and other countries. Android® is a registered trademark of Google Inc. Bluetooth® is a registered trademark of Bluetooth SIG, Inc. All other products and services mentioned may be trademarks or service marks of their respective owners. Index What's In the Box 4 Preparing the Plate Heat Exchanger 5 Preparing the G2 unit 7 Preparing the G2 unit: Tablet 8 Manuals and Guides To reduce our use of paper and to conform to our environmental/sustainability policies and responsibility, we have moved our product documentation online. For the latest Gappscan User Manual or Product Guide, please go to www.eit-international/Gappscan Think before you print! Technical Support E-Mail: Support@eit-international.com or speak to your local in country EIT-International associate. Web Site: Visit our web site at www.eit-international.com/support where you can browse our FAQ's, or request assistance. www.eit-international.com 3 What's In the Box IMPORTANT: This is a sensitive instrument and can only be operated by a trained person as certified by EIT International. If in the event of a failure please contact support@eit-international.com or call your local EIT representative. CAUTION: Modifications not expressly approved by EIT International may void the users authority to operate the equipment. The removal of any panels or components, or to open the sealed Gappscan casing will render the equipment damaged and will void any Agreements in place. Damaged Gappscan unit through the malice of any third party will render the equipment written-off and the leaseholder will be liable for all costs associated as outlined in the Gappscan Lease Agreement. Blue Hose Tablet Clamp Clamp Red Hose G2 Charger MUiScBro Tablet Charger Regulator Pressure Gauge www.eit-international.com 4 Preparing the Plate Heat Exchanger ATTENTION: Always fill heat exchanger first, never try filling the heat exchanger through the Gappscan unit as this will severely reduce battery capacity and may lead to damage of the Gappscan unit · Connect Clamps to the PHE at point A and B. Clamp A Clamp B · Connect Mains water to inlet Clamp B do not turn water flow ON. www.eit-international.com 5 · Connect Pressure Gauge supplied to outlet Clamp A. At mains water supply, turn ON and allow water to run through heat exchanger. When water still running, open and close the outlet pressure gauge valve (Clamp A) to remove excess air in the system. Ensure all air is expelled from heat exchanger. Close both valves (Clamp A and Clamp B) and wait for pressure to stabilise on gauge at Clamp A, exchanger is now full of water and the heat exchanger is now a sealed unit. Turn OFF water supply from mains water supply. Bring pressure in heat exchanger down to 3 bar using Pressure Gauge at Clamp A and leave. The plate heat exchanger is now prepped and ready. www.eit-international.com 6 Preparing the G2 unit 1. Turn the G2 unit to POWER, this will now self-purge automatically. Wait for purge to complete. 4. Connect water out hose to G2 unit at Point B (do not connect to heat exchanger). 2. Connect Pressure Regulator to G2 inlet. 5. Turn ON water supply at source. 3. Connect mains water to pressure regulator. www.eit-international.com 7 Tablet 1. Turn on G2 tablet and select `G2 AE Easytesters' App. 3. Once registered, select SET UP to connect to G2, Bluetooth connection will be applied and Click next once Bluetooth has confirmed. 2. Register Tablet with Username and Password supplied by EIT-International. 4. Fill in Job Number and all other details required by using the drop down menus, as programmed on the G2 website. www.eit-international.com 8 5. Enter TARGET PRESSURE and select NEXT (as Heat Exchanger is now at 3 Bar our target pressure must also be 3 BAR). 8. Follow Connection Procedure as explained then select NEXT. 6. Select CHARGE. 9. Select BLEED, G2 unit will now run water through Point B and eliminate any air pockets within. 7. Select NEXT. www.eit-international.com 9 10. Once bleeding has expelled all the air, connect Water out Hose to Clamp B. DO NOT open flow valve on Clamp B at this point. 12. Select COMPLETE. 13. Select MONITOR, watch for green STABLE sign to show (top right hand side of the screen). Select TEST once Status is STABLE. 11. On tablet select CHARGE, follow instructions on tablet. CONFIRM once instructions have been followed Make sure Clamp B Valve is now open. www.eit-international.com 10 14. Set 3 minutes for duration of test and select START TEST. 17. Select RESULTS then -> Select END TEST. 15. Test will start and show the following information. 18. Follow Instructions below and either select PURGE to finish tests or Select MONITOR to test again. 16. When test has completed Select GENERATE REPORT -> Select SAVE REPORT. www.eit-international.com 11 19. The test has now completed. Select UPLOAD REPORTS -> Select UPLOAD REPORTS -> Tap the Test you want to upload -> Select UPLOAD. NB Tablet must be connected to Internet to upload. 20. Turn off mains water at source. On Clamp B water flow lever must now be turned OFF. On tablet select PURGE to empty excess water from the G2 unit. Turn the G2 unit to STANDBY. Remove hose from Point A. Remove hose from Point B. Open Clamp A on heat exchanger and allow pressure to normalise. www.eit-international.com 12 EIT International Biopharma House Winnall Valley Road Winnall Winchester United Kingdom SO23 0LD For Service and Support e-mail us at support@eit-international.com w www.eit-international.com EIT International