Introduction
This instruction manual provides detailed information for the Anko Wearable Breast Pump (Model: JLR-78346). It covers product features, components, assembly, usage, care, and troubleshooting.
The illustrations in this manual are for reference only. Actual product may vary slightly. The manufacturer reserves the right to change specifications without prior notice.
IMPORTANT! PLEASE READ CAREFULLY BEFORE USE AND KEEP FOR FUTURE REFERENCE.
Warnings
- Ensure to turn off the device after each use. Do not use unoriginal parts.
- To ensure optimal personal hygiene, do not share this product with others to avoid potential health risks.
- The breast pump contains a non-replaceable lithium battery. For good power storage, avoid long-term over-charging.
- Do not place this item near a heat source or in direct sunlight.
- Do not use this product while lying down or leaning back. Stop using if feeling sleepy.
- Do not immerse the breast pump in water or any other liquid. Do not use while bathing.
- Do not disassemble the product yourself to avoid affecting warranty rights.
- To prolong the service life of the power cord, do not wind it up tightly for storage.
- Keep all components not in use away from babies and children.
- This product cannot be used while charging. Ensure it is fully charged before use.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless supervised or instructed by a person responsible for their safety.
- Children should be supervised to ensure they do not play with the appliance.
- The appliance must only be supplied at safe extra low voltage corresponding to the marking on the appliance.
- This appliance contains batteries that are non-replaceable.
- The supplied USB charging cable should be inserted into a standard USB power source rated at 5V d.c., 1A. Refer to the Power description section for charging details.
Caution
- Please read the instructions carefully before use.
- Do not immerse this electrical device in water or a steam steriliser.
- Ensure you do not twist the connecting tube or knot it during use.
- Please seek medical advice and guidance when using this product during a less lactation stage.
- For hygiene reasons, do not share this product with anybody else.
- This item is not a toy. Do not allow children to use or play with it. KEEP THIS ITEM AWAY FROM BABIES AND CHILDREN.
- Do not disassemble this product if it is damaged.
- This appliance contains non-replaceable batteries.
Product Components
The wearable breast pump includes the following parts:
No. | Part Name | Material | Heat resistance temperature | Quantity |
---|---|---|---|---|
1 | Type-C charging cable (Adaptor not included) | 1 | ||
2 | Pump | 1 | ||
3 | Suction Valve | Silicone | 2 | |
4 | Duckbill valve | Silicone | -20°C/-4°F - 160°C/320°F | 2 |
5 | Breast Shield | Polypropylene | 2 | |
6 | Milk Storage Cups (180ml each) | Polypropylene | -20°C/-4°F - 100°C/212°F | 2 |
7 | Suction cap | Polypropylene | 2 | |
8 | Tube | Silicone | 2 | |
9 | 21mm Flange | Silicone | 2 | |
10 | 24mm Flange | Silicone | 2 | |
11 | Lanyard | Nylon | 1 |
Illustration of the wearable breast pump unit with its various components, showing an exploded view with numbered parts.
Product Specification
- Power Supply: 5V ⎓ 1A
- Battery Capacity: 1500mAh
Product Features
- Hands-free portable breast pump.
- Rechargeable (USB charging cable included).
- 4 modes, each with 9 levels:
- Single side alternating massage
- Single side alternating suction
- Double side simultaneous massage
- Double side simultaneous suction
- Automatically switches from massage to suction mode.
- Anti-backflow design.
- Silicone edged flanges for comfort.
- Ultra-lightweight milk storage cups (80gm each).
- On/off button.
- Digital display pump monitor.
- 30-minute timer function.
- Quiet operation: less than 62dB.
- Lanyard for easy portability.
Assembly Method
Note: The following illustrations are for reference only. All accessories must be assembled correctly to ensure proper suction and prevent milk spillage.
- Assemble the suction valve over the breast shield. Press both sides firmly with both hands to ensure it is secure.
- Assemble the duckbill valve under the breast shield.
- Assemble the suction cap and press it tightly to ensure it is secure.
- Assemble the milk collecting cup according to the direction shown in the figure. Use the provided tube to connect both sides.
Diagrams illustrating the assembly steps: attaching the suction valve to the breast shield, attaching the duckbill valve, attaching the suction cap, and connecting the milk collecting cup and tubing.
How to Wear
Choose the correct size flange and assemble it into the breast shield for each side. Place over your breast and align your nipple with the center of the breast shield. Repeat on the other side.
Illustration showing how to position the breast shield and flange onto the breast, aligning the nipple with the center.
LED Display Instructions
The device features several LED indicators:
- LED indicator of function levels: Indicates the current mode and suction level.
- LED battery level indicator: Shows the remaining battery power.
- Suction time indicator: Displays the duration of the pumping session.
- Mode switch: Button to cycle through different modes.
- Levels increase: Button to increase suction level.
- Levels decrease: Button to decrease suction level.
- Power button: Turns the device on/off, and pauses/resumes pumping.
- Charging socket: Port for the USB charging cable.
- Mode Indicators: Icons for Alternate massage mode, Alternate suction mode, Simultaneous massage mode, and Simultaneous suction mode.
- Tube socket A & B: Ports for connecting the tubing.
Diagram of the breast pump unit with labels pointing to LED indicators and buttons.
Usage Instructions
- Before pumping, wash your hands. It is recommended to wipe your breasts with a warm, clean towel.
- This device provides 4 modes: Alternate massage mode, Alternate suction mode, Simultaneous massage mode, Simultaneous suction mode.
- Short press the power button to turn the device on. While on, short press the power button to pause massage or suction, and another short press to start again. Long press the power button to turn off the device. (If the power turns off due to insufficient power, it can only be turned on after charging).
- Levels: 1-9 for each of the 4 modes. Press the 'Levels increase' or 'Levels decrease' buttons to adjust the suction value.
- Short press the mode switch button to switch to another mode.
- When you turn the device on, it will enter the Alternate massage mode with the last used level. You can switch the working mode by pressing the mode switch button. During use, the suction value can be adjusted by the 'Levels increase' or 'Levels decrease' buttons.
- This product will turn off automatically and safely after 30 minutes of use.
- The suction time indicator will be on for 9-10 seconds during no operation, and then start to show time:
- Within 59 seconds, the display shows time in seconds.
- After 60 seconds, the display shows time in minutes (1-30 minutes).
Power Description
- The device contains a 1500mAh lithium battery. One full charge takes approximately 4 hours.
- When the battery capacity is lower than 30%, the LED battery indicator will display a flashing light.
- When charging, the LED battery indicator displays a flashing light. When fully charged, the full charging indicator will stop flashing.
Tips for Use
- The size of the breast shield will not affect the quantity of milk collected but will affect the comfort of use.
- The breast shield should be aligned with the center of the breast. Ensure that the nipple does not touch the breast shield to avoid stimulating friction pain.
- This item comes with 2 size flanges (21mm and 24mm). Please ensure you use the most comfortable fit.
- If you feel any pain or discomfort, turn off the power and reposition the breast shield. Restart the unit with the first level of suction. If pain or discomfort persists, stop using the item immediately and consult your doctor.
How to Pour Out Breast Milk
- After milk collection, pull out the pump first and hold the breast shield upward to avoid breast milk spillage.
- Prepare the milk storage bottle and pour out the breast milk according to the correct milk pouring method shown below.
Diagram illustrating the correct and incorrect methods for pouring breast milk from the collection cup into a storage bottle, emphasizing keeping the breast shield upward to prevent spillage.
How to Store Breast Milk
- Considering the expansion of breast milk after freezing, it is recommended to store up to 3/4 of the bottle's capacity before freezing.
- It is recommended that each milk storage capacity is about 180mL for faster thawing and to prevent waste from babies unable to consume larger quantities.
- It is recommended to mark the date on the outside of each milk storage container.
- Thawed breast milk should be placed in cold storage for several hours or thawed with warm water at about 40°C/104°F. If using warm water, gently shake the breast milk to prevent fat separation.
- Thawed breast milk cannot be frozen again and must be consumed within 24 hours.
Cleaning Method
Unit:
- Do not wash or disinfect the main unit in water.
- Wipe the surface with paper towels.
- If accidentally dropped into water or other liquids, DO NOT use this product.
Accessories:
- Parts are hand or machine washable.
- May be sterilized by steam, ultraviolet, and boiling water. The ultraviolet method may cause some yellowing, which is acceptable. For boiling water sterilization, turn off the heat source after boiling and wait for 3 minutes before use.
- Allow parts to air dry.
- Silicone accessories are recommended to be soaked in hot water and cleaned regularly.
Troubleshooting Methods
If the appliance is not working:
- Check the battery power. Replace the power adaptor if necessary. Ensure the adaptor interface is inserted correctly into the host's DC interface.
If the product has insufficient suction:
- Replace parts of the closed valve. Check if the closed valve is installed correctly. Usually, putting the closed valve in boiling water for 3 minutes and then assembling it can help restore suction.
- Ensure that the breast shield is securely rested on the breast and that there is no air leakage.
- If the room temperature is below 15°C, allow the unit to run for an additional 30 seconds to provide time for breast suction operation.
12 Month Warranty
Thank you for your purchase. Your new product is warranted to be free from defects in materials and workmanship for the period stated above, from the date of purchase, provided it is used in accordance with accompanying recommendations or instructions. This warranty is in addition to your rights under the Australian Consumer Law.
For New Zealand customers, this warranty is in addition to statutory rights observed under New Zealand legislation.
The company will provide a refund, repair, or exchange for this product if it becomes defective within the warranty period. The business will bear reasonable expenses for claiming the warranty.
This warranty does not apply if the defect is a result of alteration, accident, misuse, abuse, or neglect.
Please retain your receipt as proof of purchase. Contact the Customer Service Centre listed below for any product difficulties.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if they fail to be of acceptable quality and the failure does not amount to a major failure.
Contact Information
Contact for Kmart purchases
Kmart Australia Ltd.
C/- Customer Service Centre
690 Springvale Road,
Mulgrave Vic 3170
Customer Service: 1800 124 125 (Australia) or 0800 945 995 (New Zealand) or via Customer Help at kmart.com.au
Contact for Target purchases
Target Australia Pty Ltd
C/- Customer Service Centre
2 Kendall Street, Williams Landing,
Vic, 3027
Customer Service: 1300 753 567 or via Customer Help at target.com.au/help/contact-us