User Guide for Bard models including: Q-TEC QWS Series High Efficiency Geothermal, Heat Pump R-410A
both soft and manual lockouts for high and low pressure controls. High Pressure Switch: Protects refrigerant circuit against excessively high pressure. Low Pressure Switch: Provides loss of charge protection plus protects against freeze-up of coaxial coil during heating mode due to water flow or temperature problems. Two
The Q-TEC Series self contained packaged water-to-air heat pump is designed to be installed inside a building structure against an exterior exposed wall ...
Form No. S3419-0521 Supersedes S3419-617 Page 1 of 26 The Q-TEC Series self contained packaged water-to-air heat pump is designed to be installed inside a building structure against an exterior exposed wall when ventilation
File Info : application/pdf, 26 Pages, 1.03MB
DocumentDocumentQ-TECTM QWS Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump -- R-410A 2 to 5 Ton 2-Stage Compressors Extended Range Operation: 25° to 110°F EWT The Q-TEC Series self contained packaged water-to-air heat pump is designed to be installed inside a building structure against an exterior exposed wall when ventilation option is selected. When no ventilation option is used, the QWS Series units can be installed in any interior space accessible to water supply system and condensate drain. Q-TEC's design provides "whisper" quiet operation with total comfort for the occupants at high efficiency levels and eliminates the need for roof-mounted equipment and outside condensing units and can meet your specific architectural requirements. Q-TEC's "quiet technology" provides extremely low indoor sound levels by using special components and materials in the construction of the unit. By using special motors and sound insulation we have built a heat pump system that is significantly quieter than competitive product available today. Q-TEC is suitable for both new construction and renovation projects for schools, modular buildings and light commercial buildings. A variety of ventilation options are designed to address your project's indoor air quality. The Q-TEC Series unique design allows all maintenance and service to be performed inside the building to facilitate multi-story installations. Access to air filters and controls is accomplished through a hinged front panel for easy accessibility. All Q-TEC Series models are built on heavy duty permanent rollers for easy installation and removal. Engineered Features Step Capacity Compressor: Copeland step capacity (2-stage) scroll compressors are designed for increased efficiency, quieter operation and improved reliability for longer life. Reduced Sound Level: Compressor sound cover and double isolation grommets reduce sound levels. Discharge muffler used on all models. R-410A Refrigerant: Designed with R-410A (HFC) non-ozone depleting refrigerant in compliance with the Montreal protocol and 2010 EPA requirements. Electrical Components: Are easily accessible for routine inspection and maintenance through front service panels. Circuit breaker standard on all 208/230V models and rotary disconnect standard on all 460V models. Circuit breaker/rotary disconnect access is through lockable access panel. Lock and key provided as standard equipment. Hot Water Coil: A plenum mounted hot water coil is available for both duct-free and ducted applications. Liquid Line Filter Drier: Standard on all models. Air Filter: Two-inch pleated MERV 8 filter is standard. Phase Rotation Monitor: Standard on all 3 phase scroll compressors. Protects against reverse rotation if power supply is not properly connected. Indoor Blower System: All models feature a variable speed (ECM) motor providing super high efficiency, low sound levels and soft start capabilities. The motor is self adjusting to provide the proper airflow rate at high static pressure for ducted installations without user adjustment or wiring changes. Dual blower and 30-second ramp up and ramp-down on motor used for quiet operation. High Efficiency Coaxial Water Coil: Fully insulated to minimize sweating. Copper or cupro-nickel coils available. Copper coils approved for Ground Loop and Closed Loop Boiler / Tower only. Fluid Flow Switch: Provided for coaxial coil to protect against loss of water flow. Double O-Ring Water Connections (Optional): Positive water-tight connections with built-in union. 1" female NPT fittings also available. Pumping System: Unit can be connected to central piping/pumping system from well field, boiler/tower or optional pump module can be installed inside unit for individual earth loop applications. Copper Tube/Aluminum Fin Evaporator Coil: Grooved copper tubing and enhanced aluminum fins provide maximum heat transfer and high energy efficiency. Evaporator coil constructed with hydrophilic fin stock that seals fin surface against aluminum oxide formation, is resistant to mold and mildew growth (tested to ASTM D3273, no growth) and reduces beading of condensate on the fin surface. Cabinet: Constructed of 20 gauge pre-painted or vinyl laminated galvanized steel. Choice of either two tone vinyl finish with "slate" front panels and "platinum" cabinet for designer appearance, or painted steel. Vinyl finish is very resistant to scratching and marring and is very easy to clean. Tamper resistant fasteners are provided for access panels. Unit includes built-in rollers for easy installation into wall sleeve and removal for service if necessary. Hinged, lockable front panel for filter service and access to primary functional electrical controls. Compressor Control Module: Built-in off-delay timer adjustable from 30 seconds to 5 minutes. Two-minute on-delay if power interrupt. 120-second bypass for low pressure control, and both soft and manual lockouts for high and low pressure controls. High Pressure Switch: Protects refrigerant circuit against excessively high pressure. Low Pressure Switch: Provides loss of charge protection plus protects against freeze-up of coaxial coil during heating mode due to water flow or temperature problems. Two switches are installed, and the factory wired switch is for fresh water applications. Diagnostic Light: System service - indicates high or low pressure switch operation for compressor protection. Located inside control panel. Stainless Steel Drain Pan: Provides extended life of the evaporator drain pan for maximum corrosion resistance. Side Trim Piece Extension Optional: Trim kits available for covering the space between unit and wall for spaces from 4" to 12". Optional Ventilation Packages: Optional energy recovery ventilator can provide up to 450 cfm of outside air and exhaust through the unit while maintaining indoor comfort and humidity levels. Other available options include commercial room ventilator with exhaust, and barometric damper without exhaust. Outside wall and ventilation sleeve are required for installations with ventilation option. Optional Ventilation Wall Sleeve: Required for ventilation options only. Constructed of 16 gauge galvanized steel, coated with epoxy primer and a baked on polyester enamel paint, which allows it to withstand 1000 hours of salt spray tests per ASTM B117-03. Ordered separately. Insulation: Cabinet is fully insulated with foil covered, high density fiberglass insulation with sealed edge treatment and special sound deadening insulation material in the compressor section. All insulation is designed to resist mold and mildew growth and facilitate ease of cleaning. Form No. S3419-0521 Supersedes S3419-617 Page 1 of 26 Specifications - 2 and 3 Ton MODELS ELECTRICAL RATING 60 HZ Operating Voltage Range COMPRESSOR CIRCUIT A Voltage Rated Load Amps Branch Circuit Selection Current Lock Rotor Amps MOTOR & EVAPORATOR Blower Motor HP/SPD Blower Motor Amps Filter Sizes (inches) STD. SHIPPING WEIGHT LBS. QW2S2-A QW2S2-B 230/208 - 1 230/208 - 3 197-253 QW2S2-C 460 - 3 414-506 230/208 460 9.1/10.6 5.1/5.9 3.2 11.7 6.5 3.5 58.3 55.4 28 1/3 / Variable 2.4 1 - 16x20x2 & 1 - 16x16x2 530 530 550 QW3S2-A QW3S2-B 230/208 - 1 230/208 - 3 197-253 QW3S2-C 460 - 3 414-506 230/208 460 13.2/15.8 10.1/12.0 6.0 15.8 12 6.0 83 73 38 1/2 / Variable 3.1 1 - 16x20x2 & 1 - 16x16x2 535 535 555 Specifications - 4 and 5 Ton MODELS ELECTRICAL RATING 60 HZ Operating Voltage Range COMPRESSOR CIRCUIT A Voltage Rated Load Amps Branch Circuit Selection Current Lock Rotor Amps MOTOR & EVAPORATOR Blower Motor HP/SPD Blower Motor Amps Filter Sizes (inches) STD. SHIPPING WEIGHT LBS. QW4S2-A QW4S2-B 230/208 - 1 230/208 - 3 197-253 QW4S2-C 460 - 3 414-506 230/208 460 18.7/22.1 12.4/14.7 6.7 22.1 14.7 6.7 104 83.1 41 3/4 / Variable 3.6 1 - 16x25x2 & 1 - 16x16x2 555 555 575 QW5S2-A QW5S2-B 230/208 - 1 230/208 - 3 197-253 QW5S2-C 460 - 3 414-506 230/208 460 21.1/23.3 12.8/14.2 6.3 27.2 16.6 7.3 152.9 110 52 3/4 / Variable 4.0 1 - 16x25x2 & 1 - 16x16x2 620 620 645 See Page 9 for Electrical Specifications Indoor Blower Performance CFM (0.00" through 0.50" H O) 2 Model Rated ESP. Max. ESP j Blower Only k Rated 1st Stage 2nd Stage De-Rated l 2nd Stage Rated m QW2S2 0.10 0.5 600 800 900 950 QW3S2 0.15 0.5 675 900 1050 1150 QW4S2 0.20 0.5 825 1200 1300 1450 QW5S2 0.20 0.5 875 1400 1500 1650 NOTE: These units are equipped with a variable speed (ECM) indoor motor that automatically adjusts itself to maintain approximately the same rate of indoor airflow in both heating and cooling, dry and wet coil conditions, and at both 230/208 or 460 volts. j Maximum ESP (inches WC) shown is with 2" MERV 6 pleated filter. k Continuous CFM the total airflow being circulated during continuous blower operation. l Optional 2nd Stage CFM the unit is factory shipped to operate on full 2nd Stage airflow. If the optional 2nd Stage airflow is desired, it requires removal of gray wire from "Y2" terminal of low voltage terminal strip in unit main control panel. This reduces system capacity performance by approximately 2% total (-4% Sensible, +2% Latent) at the same energy efficiency. m Rated CFM for ducted applications required for maximum performance rating. Form No. S3419-0521 Supersedes S3419-617 Page 2 of 26 ISO 13256-1 Performance Data j MODEL QW2S QW3S QW4S QW5S System Capacity Modulation Full Part Full Part Full Part Full Part Fluid Flow Rate GPM 7.0 8.0 9.0 11.0 Airflow CFM 950 800 1150 900 1450 1200 1650 1400 MODEL QW2S QW3S QW4S QW5S System Capacity Modulation Full Part Full Part Full Part Full Part Fluid Flow Rate GPM 6.1 8.6 11.5 13.7 Airflow CFM 950 800 1150 900 1450 1200 1650 1400 Ground Loop Heat Pump AHRI Certified to ISO 13256-1:1998 Cooling Brine Full Load 77°F Part Load 68°F Heating Brine Full Load 32°F Part Load 41°F Capacity BTUH EER BTU/W Capacity BTUH COP 25,600 20,200 18.2 24.8 19,600 15,600 3.95 4.00 35,600 27,200 17.0 22.5 29,000 22,000 3.65 3.85 49,500 38,000 17.2 22.4 36,000 30,000 3.35 3.85 58,500 45,500 16.4 21.6 46,000 38,000 3.60 4.05 Water Loop Heat Pump AHRI Certified to ISO 13256-1:1998 Cooling -- EWT 86°F Heating -- EWT 68°F Capacity BTUH EER BTU/W Capacity BTUH COP 24,800 17,800 15.6 17.4 31,600 24,000 5.20 5.95 35,400 25,600 15.0 16.0 44,600 33,000 4.30 5.10 47,500 35,000 15.1 16.0 57,000 43,000 4.30 4.80 56,500 42,000 14.5 15.6 69,500 52,000 4.40 4.95 j ISO Standard 13256-1:1998, "Water to Air and Brine to Air Heat Pumps", which includes watt allowance for water pumping. Cooling capacity based on 80.6°F DB, 66.2°F WB entering air temperature. Heating capacity based on 68°F DB entering air temperature. All 1-phase models meet the minimum efficiency requirements of the Energy Star (ES) efficiency program for Ground Loop applications. Currently, there is no ES efficiency program for 3-phase equipment or for Water Loop applications. Correction Factors @ Increased Water Flows Rated Flow Plus 2 GPM 3 GPM 4 GPM Cooling BtuH Watts 1.005 0.988 1.007 0.984 1.008 0.979 Heating BtuH Watts 1.006 1.002 1.009 1.003 1.011 1.003 Bard is an ISO 9001:2008 Certified Manufacturer · Intertek ETL Listed to Standard for Safety Heating and Cooling Equipment ANSI/UL 1995/CSA 22.2 No. 236-05, Fourth Edition. Form No. S3419-0521 Supersedes S3419-617 Page 3 of 26 QW2S2 Full Load Capacities based upon rated flow of 7 GPM of 15% methanol/mass at 950 CFM airflow. COOLING FULL LOAD HEATING FULL LOAD Entering Fluid Temp. (°F) 50° Entering Air Temp. (°F) Total Capacity (MBtuH) 25.2 Sensible Capacity (MBtuH) 19.1 Sensible to Total Ratio 0.75 Power Input (KW) 1.02 Heat of Rejection (MBtuH) 28.3 EER 21.1 Entering Fluid Temp. (°F) Entering Air Temp. (°F) Total Capacity (MBtuH) Leaving Air Temp. (°F) 60° 70° 80° 90° 100° 110° 70° DB 59° WB 24.2 23.3 22.3 21.4 20.4 19.5 18.8 18.4 18.1 17.8 17.4 17.1 0.77 0.79 0.81 0.83 0.85 0.87 1.20 1.37 1.55 1.73 1.91 2.08 27.9 27.5 27.0 26.6 26.1 25.7 19.0 16.9 14.9 12.8 10.7 8.6 25° 19.0 82.5 30° 20.3 83.8 40° 22.9 86.2 50° 65° 25.5 88.6 60° 28.8 91.7 50° 27.1 19.8 0.72 1.04 30.4 22.4 70° 32.1 94.7 60° 70° 80° 90° 100° 110° 75° DB 63° WB 26.1 25.1 24.0 23.0 22.0 21.0 19.5 19.2 18.9 18.5 18.2 17.9 0.74 0.77 0.79 0.81 0.83 0.85 1.21 1.39 1.57 1.75 1.92 2.10 30.0 29.5 29.1 28.6 28.2 27.7 20.2 18.0 15.8 13.6 11.5 9.3 80° 25° 30° 40° 50° 70° 35.4 18.5 19.8 22.4 24.9 97.8 87.2 88.3 90.7 93.1 50° 29.0 20.5 0.70 1.06 32.6 23.7 60° 28.2 96.1 60° 70° 80° 90° 100° 110° 80° DB 67° WB 28.0 26.9 25.8 24.8 23.7 22.6 20.2 19.9 19.6 19.3 19.0 18.7 0.72 0.74 0.76 0.78 0.80 0.82 1.23 1.41 1.59 1.76 1.94 2.12 32.2 31.7 31.2 30.8 30.3 29.9 21.4 19.1 16.8 14.5 12.2 9.9 70° 80° 25° 30° 40° 31.4 34.7 18.7 20.0 22.6 99.1 102.1 92.3 93.5 95.9 50° 31.1 21.2 0.67 1.08 34.9 24.9 50° 75° 25.2 98.3 60° 30.0 20.9 0.69 1.25 34.5 22.5 70° 28.8 20.6 0.71 1.43 34.0 20.1 80° 85° DB 71° WB 27.7 20.3 0.73 1.61 33.5 17.8 90° 26.6 20.0 0.76 1.78 33.0 15.4 60° 70° 80° 28.5 31.7 35.0 101.4 104.4 107.4 100° 25.4 19.7 0.78 1.96 32.6 13.0 110° 24.3 19.5 0.80 2.14 32.1 10.6 Full Load Capacities based upon rated flow of 7 GPM of 15% methanol/mass at 800 CFM airflow. COOLING PART LOAD HEATING PART LOAD Entering Fluid Temp. (°F) 50° Entering Air Temp. (°F) Total Capacity (MBtuH) 20.0 Sensible Capacity (MBtuH) 16.1 Sensible to Total Ratio 0.79 Power Input (KW) 0.58 Heat of Rejection (MBtuH) 21.8 EER 27.0 Entering Fluid Temp. (°F) Entering Air Temp. (°F) Total Capacity (MBtuH) Leaving Air Temp. (°F) 60° 70° 80° 90° 100° 110° 70° DB 59° WB 19.0 17.9 16.9 15.9 14.8 13.8 15.7 15.2 14.7 14.2 13.8 13.3 0.82 0.85 0.87 0.90 0.93 0.95 0.72 0.86 1.00 1.14 1.28 1.42 21.2 20.5 19.9 19.3 18.6 18.0 23.9 20.8 17.8 14.7 11.6 8.5 25° 11.1 77.8 30° 12.7 79.7 40° 15.9 83.4 50° 65° 19.0 87.0 60° 21.4 89.8 50° 21.5 16.7 0.77 0.59 23.4 28.6 70° 23.8 92.6 60° 70° 80° 90° 100° 110° 75° DB 63° WB 20.4 19.3 18.2 17.1 16.0 14.9 16.3 15.8 15.3 14.9 14.4 13.9 0.79 0.82 0.85 0.87 0.90 0.93 0.73 0.87 1.01 1.15 1.29 1.43 22.7 22.1 21.4 20.8 20.1 19.4 25.4 22.1 18.9 15.7 12.4 9.2 80° 25° 30° 40° 50° 70° 26.2 10.9 12.4 15.5 18.6 95.4 82.6 84.4 87.9 91.5 50° 23.0 17.3 0.74 0.60 25.1 30.3 60° 21.0 94.2 60° 70° 80° 90° 100° 110° 80° DB 67° WB 21.9 20.7 19.5 18.4 17.2 16.0 16.9 16.4 15.9 15.5 15.0 14.5 0.77 0.79 0.82 0.85 0.87 0.90 0.74 0.88 1.02 1.16 1.30 1.44 24.4 23.7 23.0 22.3 21.6 20.9 26.9 23.5 20.1 16.6 13.2 9.8 70° 80° 25° 30° 40° 23.3 25.7 11.0 12.5 15.7 97.0 99.7 87.7 89.5 93.1 50° 24.7 17.9 0.71 0.62 26.9 31.9 50° 75° 18.8 96.8 60° 23.4 17.4 0.74 0.76 26.1 28.4 70° 22.2 17.0 0.77 0.89 25.4 24.8 80° 85° DB 71° WB 20.9 16.5 0.79 1.03 24.7 21.2 90° 19.7 16.1 0.82 1.17 24.0 17.6 60° 70° 80° 21.2 23.6 25.9 99.5 102.3 105.0 100° 18.5 15.6 0.84 1.31 23.2 14.1 110° 17.2 15.1 0.87 1.45 22.5 10.5 Form No. S3419-0521 Supersedes S3419-617 Page 4 of 26 Power Input (KW) 1.51 1.54 1.60 1.67 1.76 1.84 1.93 1.55 1.58 1.65 1.72 1.80 1.89 1.98 1.74 1.77 1.85 1.93 2.02 2.12 2.22 Power Input (KW) 1.12 1.12 1.13 1.14 1.14 1.15 1.15 1.15 1.15 1.16 1.17 1.18 1.18 1.19 1.29 1.29 1.30 1.31 1.32 1.33 1.33 Heat of Absorption COP (MBtuH) 13.6 14.8 17.2 19.6 22.7 25.7 28.7 13.2 14.4 16.7 19.0 22.0 24.9 27.9 12.9 14.0 16.2 18.5 21.3 24.2 27.1 3.7 3.9 4.2 4.5 4.8 5.1 5.4 3.5 3.7 4.0 4.25 4.6 4.9 5.2 3.2 3.3 3.6 3.8 4.1 4.4 4.7 Heat of Absorption COP (MBtuH) 7.2 8.7 11.9 15.0 17.4 19.9 22.3 6.9 8.5 11.5 14.6 16.9 19.3 21.6 6.7 8.2 11.2 14.2 16.4 18.7 21.0 2.9 3.3 4.1 4.9 5.5 6.1 6.7 2.8 3.2 3.9 4.7 5.2 5.79 6.35 2.5 2.8 3.5 4.2 4.7 5.2 5.7 QW3S2 Full Load Capacities based upon rated flow of 8 GPM of 15% methanol/mass at 1150 CFM airflow. COOLING FULL LOAD HEATING FULL LOAD Entering Fluid Temp. (°F) 50° Entering Air Temp. (°F) Total Capacity (MBtuH) 32.5 Sensible Capacity (MBtuH) 22.0 Sensible to Total Ratio 0.67 Power Input (KW) 1.42 Heat of Rejection (MBtuH) 36.9 EER 19.3 Entering Fluid Temp. (°F) Entering Air Temp. (°F) Total Capacity (MBtuH) Leaving Air Temp. (°F) 60° 70° 80° 90° 100° 110° 70° DB 59° WB 31.9 31.2 30.5 29.8 29.1 28.4 22.1 22.2 22.3 22.4 22.6 22.7 0.69 0.71 0.73 0.75 0.77 0.80 1.70 1.98 2.26 2.53 2.81 3.09 37.0 37.2 37.3 37.4 37.5 37.7 17.5 15.8 14.0 12.2 10.4 8.6 25° 26.1 86.0 30° 28.2 87.7 40° 32.5 91.2 50° 65° 36.8 94.7 60° 40.5 97.6 50° 34.9 22.8 0.65 1.45 39.6 20.5 70° 44.2 100.6 60° 70° 80° 90° 100° 110° 75° DB 63° WB 34.2 33.5 32.8 32.1 31.4 30.7 23.0 23.1 23.3 23.4 23.6 23.8 0.67 0.69 0.71 0.73 0.75 0.77 1.73 2.00 2.28 2.56 2.83 3.11 39.8 40.0 40.1 40.3 40.5 40.6 18.6 16.7 14.9 13.0 11.1 9.2 80° 25° 30° 40° 50° 70° 47.9 25.5 27.6 31.8 36.0 103.5 90.5 92.2 95.6 99.0 50° 37.5 23.6 0.63 1.48 42.5 21.7 60° 39.6 101.9 60° 70° 80° 90° 100° 110° 80° DB 67° WB 36.7 36.0 35.3 34.5 33.8 33.1 23.8 24.0 24.2 24.4 24.6 24.8 0.65 0.67 0.69 0.71 0.73 0.75 1.75 2.03 2.31 2.58 2.86 3.14 42.7 42.9 43.1 43.4 43.6 43.8 19.7 17.7 15.8 13.8 11.8 9.8 70° 80° 25° 30° 40° 43.2 46.8 25.8 27.9 32.1 104.8 107.7 95.8 97.5 100.9 50° 40.1 24.4 0.60 1.51 45.5 22.8 50° 75° 36.4 104.3 60° 39.3 24.6 0.62 1.78 45.8 20.8 70° 38.6 24.8 0.64 2.06 46.0 18.7 80° 85° DB 71° WB 37.8 25.1 0.66 2.34 46.3 16.7 90° 37.1 25.3 0.68 2.61 46.5 14.6 60° 70° 80° 40.0 43.7 47.3 107.2 110.2 113.1 100° 36.3 25.6 0.70 2.89 46.8 12.6 110° 35.5 25.8 0.72 3.17 47.0 10.5 Full Load Capacities based upon rated flow of 8 GPM of 15% methanol/mass at 900 CFM airflow. COOLING PART LOAD HEATING PART LOAD Entering Fluid Temp. (°F) 50° Entering Air Temp. (°F) Total Capacity (MBtuH) 26.5 Sensible Capacity (MBtuH) 18.4 Sensible to Total Ratio 0.68 Power Input (KW) 0.72 Heat of Rejection (MBtuH) 28.7 EER 27.0 Entering Fluid Temp. (°F) Entering Air Temp. (°F) Total Capacity (MBtuH) Leaving Air Temp. (°F) 60° 70° 80° 90° 100° 110° 70° DB 59° WB 24.9 23.4 21.8 20.3 18.7 17.1 17.8 17.2 16.6 16.0 15.4 14.8 0.71 0.74 0.77 0.79 0.82 0.85 0.93 1.15 1.36 1.57 1.79 2.00 27.8 26.9 25.9 25.0 24.1 23.1 23.7 20.4 17.1 13.8 10.5 7.1 25° 17.4 82.9 30° 19.0 84.6 40° 22.2 87.8 50° 65° 25.4 91.1 60° 28.8 94.6 50° 28.5 19.1 0.66 0.73 30.8 28.7 70° 32.2 98.2 60° 70° 80° 90° 100° 110° 75° DB 63° WB 26.8 25.1 23.5 21.8 20.2 18.5 18.5 17.9 17.3 16.7 16.1 15.5 0.68 0.71 0.74 0.77 0.80 0.83 0.94 1.16 1.37 1.59 1.80 2.02 29.9 28.9 27.9 26.9 25.9 25.0 25.2 21.7 18.2 14.7 11.2 7.7 80° 25° 30° 40° 50° 70° 35.7 17.1 18.6 21.7 24.8 101.7 87.5 89.1 92.3 95.5 50° 30.5 19.8 0.63 0.75 33.1 30.3 60° 28.2 99.0 60° 70° 80° 90° 100° 110° 80° DB 67° WB 28.8 27.0 25.2 23.5 21.7 19.9 19.2 18.6 18.0 17.4 16.8 16.2 0.66 0.69 0.72 0.75 0.77 0.80 0.96 1.18 1.39 1.61 1.82 2.04 32.0 31.0 30.0 28.9 27.9 26.9 26.7 23.0 19.3 15.6 11.9 8.2 70° 80° 25° 30° 40° 31.5 34.9 17.2 18.8 21.9 102.4 105.9 92.7 94.3 97.6 50° 32.7 20.4 0.61 0.76 35.4 32.0 50° 75° 25.1 100.8 60° 30.8 19.8 0.64 0.98 34.3 28.1 70° 28.9 19.3 0.67 1.19 33.2 24.3 80° 85° DB 71° WB 27.1 18.7 0.69 1.41 32.1 20.4 90° 25.2 18.1 0.72 1.62 31.1 16.5 60° 70° 80° 28.5 31.8 35.2 104.3 107.8 111.2 100° 23.3 17.5 0.75 1.84 30.0 12.7 110° 21.4 16.9 0.78 2.05 28.9 8.8 Power Input (KW) 2.19 2.27 2.43 2.58 2.68 2.78 2.87 2.25 2.33 2.49 2.65 2.75 2.85 2.95 2.53 2.62 2.80 2.98 3.09 3.20 3.31 Heat of Absorption COP (MBtuH) 18.4 3.5 20.2 3.6 24.0 3.9 27.8 4.2 31.1 4.4 34.5 4.7 37.8 4.9 17.8 3.3 19.6 3.5 23.3 3.7 27.0 4.0 30.2 4.2 33.5 4.4 36.7 4.7 17.3 3.0 19.1 3.1 22.6 3.4 26.1 3.6 29.3 3.8 32.5 4.0 35.6 4.2 Power Input (KW) 1.55 1.57 1.61 1.65 1.70 1.75 1.81 1.59 1.61 1.65 1.69 1.75 1.80 1.86 1.79 1.81 1.85 1.90 1.96 2.02 2.08 Heat of Absorption COP (MBtuH) 12.0 3.3 13.5 3.6 16.6 4.0 19.6 4.5 22.9 5.0 26.1 5.4 29.4 5.8 11.6 3.2 13.1 3.4 16.1 3.8 19.0 4.3 22.2 4.7 25.4 5.1 28.5 5.5 11.3 2.8 12.7 3.0 15.6 3.5 18.5 3.9 21.5 4.2 24.6 4.6 27.7 5.0 Form No. S3419-0521 Supersedes S3419-617 Page 5 of 26 QW4S2 Full Load Capacities based upon rated flow of 9 GPM of 15% methanol/mass at 1450 CFM airflow. COOLING FULL LOAD HEATING FULL LOAD Entering Fluid Temp. (°F) 50° Entering Air Temp. (°F) Total Capacity (MBtuH) 52.1 Sensible Capacity (MBtuH) 32.2 Sensible to Total Ratio 0.59 Power Input (KW) 2.09 Heat of Rejection (MBtuH) 58.5 EER 21.4 Entering Fluid Temp. (°F) Entering Air Temp. (°F) Total Capacity (MBtuH) Leaving Air Temp. (°F) 60° 70° 80° 90° 100° 110° 70° DB 59° WB 48.8 45.5 42.1 38.8 35.5 32.2 31.4 30.5 29.7 28.9 28.1 27.2 0.63 0.67 0.71 0.75 0.79 0.83 2.40 2.71 3.02 3.33 3.63 3.94 56.1 53.7 51.2 48.8 46.4 43.9 19.1 16.8 14.4 12.1 9.8 7.4 25° 33.0 87.6 30° 35.3 89.2 40° 39.9 92.4 50° 65° 44.6 95.6 60° 50.0 99.3 50° 56.0 33.4 0.57 2.13 62.9 22.7 70° 55.4 103.0 60° 70° 80° 90° 100° 110° 75° DB 63° WB 52.4 48.9 45.4 41.8 38.3 34.7 32.6 31.8 31.0 30.2 29.4 28.5 0.61 0.65 0.69 0.73 0.77 0.81 2.44 2.74 3.05 3.36 3.67 3.97 60.3 57.7 55.2 52.6 50.0 47.5 20.3 17.8 15.4 12.9 10.4 8.0 80° 25° 30° 40° 50° 70° 60.9 32.2 34.5 39.1 43.6 106.7 92.1 93.7 96.8 99.9 50° 60.0 34.6 0.55 2.17 67.4 24.1 60° 48.9 103.5 60° 70° 80° 90° 100° 110° 80° DB 67° WB 56.3 52.5 48.7 45.0 41.2 37.4 33.8 33.0 32.2 31.4 30.6 29.8 0.59 0.63 0.67 0.70 0.74 0.78 2.47 2.78 3.09 3.39 3.7 4.01 64.7 62.0 59.3 56.5 53.8 51.1 21.5 18.9 16.3 13.7 11.1 8.6 70° 80° 25° 30° 40° 54.2 59.5 32.6 34.9 39.5 107.2 110.8 97.3 98.9 102.1 50° 64.3 35.7 0.53 2.21 72.2 25.3 50° 75° 44.1 105.2 60° 60.3 34.9 0.57 2.51 69.3 22.6 70° 56.3 34.2 0.61 2.82 66.4 19.9 80° 85° DB 71° WB 52.3 33.4 0.64 3.13 63.6 17.2 90° 48.3 32.6 0.68 3.43 60.7 14.5 60° 70° 80° 49.4 54.8 60.2 108.9 112.6 116.3 100° 110° 44.2 40.2 31.8 31.0 0.72 0.76 3.74 4.04 57.8 54.9 11.8 9.1 Full Load Capacities based upon rated flow of 9 GPM of 15% methanol/mass at 1200 CFM airflow. COOLING PART LOAD HEATING PART LOAD Entering Fluid Temp. (°F) 50° Entering Air Temp. (°F) Total Capacity (MBtuH) 37.4 Sensible Capacity (MBtuH) 26.7 Sensible to Total Ratio 0.71 Power Input (KW) 1.07 Heat of Rejection (MBtuH) 40.8 EER 26.6 Entering Fluid Temp. (°F) Entering Air Temp. (°F) Total Capacity (MBtuH) Leaving Air Temp. (°F) 60° 70° 80° 90° 100° 110° 70° DB 59° WB 35.4 33.4 31.4 29.4 27.4 25.4 25.5 24.4 23.3 22.2 21.1 20.0 0.72 0.73 0.74 0.76 0.77 0.78 1.36 1.64 1.93 2.21 2.50 2.78 39.6 38.4 37.2 36.0 34.9 33.7 23.5 20.3 17.2 14.1 11.0 7.9 25° 23.1 83.6 30° 25.1 85.2 40° 29.0 88.4 50° 65° 32.9 91.5 60° 36.4 94.3 50° 40.2 27.7 0.68 1.09 43.8 28.2 70° 39.9 97.1 60° 70° 80° 90° 100° 110° 75° DB 63° WB 38.1 36.0 33.8 31.7 29.6 27.4 26.6 25.4 24.3 23.2 22.1 20.9 0.69 0.71 0.72 0.73 0.75 0.76 1.38 1.66 1.95 2.23 2.52 2.80 42.5 41.3 40.1 38.8 37.6 36.4 24.9 21.6 18.3 15.0 11.7 8.5 80° 25° 30° 40° 50° 70° 43.4 22.6 24.5 28.4 32.2 99.9 88.2 89.7 92.8 95.9 50° 43.1 28.7 0.66 1.12 46.9 29.8 60° 35.6 98.7 60° 70° 80° 90° 100° 110° 80° DB 67° WB 40.9 38.6 36.3 34.1 31.8 29.5 27.5 26.4 25.3 24.1 23.0 21.9 0.67 0.68 0.70 0.71 0.72 0.74 1.40 1.69 1.97 2.26 2.54 2.83 45.6 44.4 43.1 41.8 40.5 39.2 26.4 22.9 19.4 16.0 12.5 9.1 70° 80° 25° 30° 40° 39.0 42.4 22.8 24.8 28.7 101.4 104.1 93.4 94.9 98.1 50° 46.2 29.6 0.63 1.14 20.3 31.4 50° 75° 32.6 101.2 60° 43.8 28.5 0.65 1.42 48.9 27.8 70° 41.4 27.3 0.66 1.71 47.5 24.2 80° 85° DB 71° WB 39.0 26.2 0.67 1.99 46.2 20.6 90° 36.6 25.0 0.69 2.28 44.8 16.9 60° 70° 80° 36.0 39.4 42.9 104.0 106.7 109.5 100° 34.1 23.9 0.70 2.57 43.5 13.3 110° 31.7 22.8 0.71 2.85 42.1 9.7 Form No. S3419-0521 Supersedes S3419-617 Page 6 of 26 Power Input (KW) 2.89 2.97 3.12 3.26 3.47 3.67 3.88 2.97 3.05 3.20 3.35 3.56 3.77 3.98 3.33 3.42 3.59 3.76 4.00 4.23 4.47 Power Input (KW) 2.09 2.12 2.17 2.22 2.26 2.30 2.34 2.15 2.18 2.23 2.28 2.32 2.36 2.40 2.42 2.44 2.50 2.56 2.60 2.65 2.70 Heat of Absorption COP (MBtuH) 22.8 3.4 24.8 3.5 29.0 3.7 33.1 4.0 37.8 4.2 42.6 4.4 47.3 4.6 22.1 3.2 24.1 3.3 28.1 3.6 32.2 3.8 36.7 4.0 41.3 4.2 45.9 4.4 21.4 2.9 23.4 3.0 27.3 3.2 31.2 3.4 35.6 3.6 40.1 3.8 44.5 4.0 Heat of Absorption COP (MBtuH) 15.7 3.2 17.6 3.5 21.4 3.9 25.2 4.3 28.5 4.7 31.9 5.1 35.2 5.5 15.2 3.1 17.1 3.3 20.7 3.7 24.4 4.1 27.7 4.5 30.9 4.8 34.2 5.2 14.8 2.8 16.6 3.0 20.1 3.3 23.7 3.7 26.9 4.0 30.0 4.4 33.2 4.7 QW5S2 Full Load Capacities based upon rated flow of 11 GPM of 15% methanol/mass at 1650 CFM airflow. COOLING FULL LOAD HEATING FULL LOAD Entering Fluid Temp. (°F) 50° Entering Air Temp. (°F) Total Capacity (MBtuH) 55.3 Sensible Capacity (MBtuH) 36.1 Sensible to Total Ratio 0.65 Power Input (KW) 2.37 Heat of Rejection (MBtuH) 62.6 EER 19.6 Entering Fluid Temp. (°F) Entering Air Temp. (°F) Total Capacity (MBtuH) Leaving Air Temp. (°F) Power Input (KW) 60° 53.2 35.3 0.66 2.82 61.8 17.6 25° 42.2 91.9 3.83 70° 51.1 34.5 0.68 3.26 61.0 15.7 80° 70° DB 59° WB 49.0 33.7 0.69 3.71 60.2 13.7 30° 40° 45.0 50.6 93.7 97.3 3.94 4.18 90° 46.9 32.9 0.70 4.15 59.4 11.74 100° 44.8 32.1 0.72 4.60 58.6 9.7 50° 65° 56.3 100.9 4.42 110° 42.7 31.3 0.73 5.04 57.8 7.8 60° 62.7 105.0 4.71 50° 59.4 37.5 0.63 2.41 67.2 20.8 70° 69.1 109.1 5.00 60° 70° 80° 90° 100° 110° 75° DB 63° WB 57.2 55.0 52.7 50.5 48.3 46.1 36.7 35.9 35.2 34.4 33.6 32.8 0.64 0.65 0.67 0.68 0.69 0.71 2.86 3.30 3.75 4.19 4.64 5.08 66.4 65.6 64.8 64.0 63.2 62.4 18.7 16.6 14.6 12.5 10.4 8.4 80° 25° 30° 40° 50° 70° 75.4 41.3 44.0 49.5 55.0 113.2 96.3 98.1 101.6 105.1 5.28 3.93 4.05 4.3 4.54 50° 63.7 38.8 0.60 2.46 72.1 22.0 60° 61.3 109.1 4.84 60° 70° 80° 90° 100° 110° 80° DB 67° WB 61.3 59.0 56.7 54.3 52.0 49.7 38.1 37.3 36.5 35.8 35.0 34.2 0.62 0.63 0.65 0.66 0.67 0.69 2.90 3.35 3.79 4.24 4.68 5.12 71.2 70.4 69.6 68.8 68.0 67.2 19. 17.6 15.5 13.3 11.1 8.9 70° 80° 25° 30° 40° 67.5 73.8 41.7 44.5 50.0 113.1 117.1 101.6 103.4 107.0 5.13 5.43 4.41 4.55 4.82 50° 68.2 40.1 0.58 2.51 77.1 23.1 50° 75° 55.6 110.5 5.10 60° 65.7 39.4 0.60 2.95 76.3 20.9 70° 63.2 38.6 0.61 3.40 75.5 18.6 80° 85° DB 71° WB 60.8 37.9 0.62 3.84 74.7 16.3 90° 58.3 37.1 0.64 4.28 73.8 14.1 60° 70° 80° 61.9 68.2 74.6 114.5 118.6 122.6 5.43 5.76 6.09 Heat of Absorption COP (MBtuH) 28.7 3.2 31.1 3.3 35.9 3.5 40.7 3.7 46.1 3.9 51.5 4.0 56.9 4.2 27.8 3.1 30.2 3.2 34.8 3.4 39.5 3.5 44.7 3.7 50.0 3.9 55.2 4.0 27.0 2.8 29.3 2.9 33.8 3.0 38.3 3.2 43.4 3.3 48.5 3.5 53.6 3.6 100° 110° 55.8 53.4 36.4 35.6 0.65 0.66 4.73 5.17 73.0 72.2 11.8 9.5 Full Load Capacities based upon rated flow of 11 GPM of 15% methanol/mass at 1400 CFM airflow. COOLING PART LOAD HEATING PART LOAD Entering Fluid Temp. (°F) 50° Entering Air Temp. (°F) Total Capacity (MBtuH) 43.4 Sensible Capacity (MBtuH) 29.4 Sensible to Total Ratio 0.67 Power Input (KW) 1.41 Heat of Rejection (MBtuH) 47.8 EER 23.7 Entering Fluid Temp. (°F) Entering Air Temp. (°F) Total Capacity (MBtuH) Leaving Air Temp. (°F) Power Input (KW) 60° 70° 80° 90° 100° 110° 70° DB 59° WB 41.4 39.5 37.5 35.6 33.6 31.6 28.6 27.8 26.9 26.1 25.3 24.5 0.69 0.70 0.72 0.74 0.75 0.77 1.78 2.16 2.53 2.91 3.29 3.66 46.9 46.0 45.2 44.3 43.4 42.6 21.0 18.3 15.6 12.9 10.2 7.5 25° 30.8 87.8 2.85 30° 32.9 89.4 2.90 40° 37.2 92.6 3.00 50° 65° 41.5 95.8 3.11 60° 46.4 99.4 3.21 50° 46.6 30.5 0.65 1.43 51.3 25.1 70° 51.4 103.0 3.32 60° 70° 80° 90° 100° 110° 75° DB 63° WB 44.5 42.5 40.4 38.3 36.2 34.2 29.7 28.9 28.1 27.3 26.5 25.7 0.66 0.68 0.70 0.71 0.73 0.75 1.81 2.19 2.56 2.94 3.31 3.69 50.4 49.5 48.6 47.7 46.9 46.0 22.3 19.4 16.6 13.8 10.9 8.1 80° 25° 30° 40° 50° 70° 56.3 30.1 32.2 36.4 40.6 106.7 92.3 93.9 97.0 100.1 3.43 2.93 2.98 3.09 3.19 50° 50.0 31.6 0.62 1.46 55.0 26.5 60° 45.4 103.6 3.30 60° 70° 80° 90° 100° 110° 80° DB 67° WB 47.8 45.6 43.4 41.2 39.0 36.8 30.8 30.0 29.2 28.4 27.6 26.8 0.64 0.66 0.67 0.69 0.71 0.72 1.84 2.22 2.59 2.97 3.35 3.72 54.1 53.2 52.2 51.3 50.4 49.5 23.6 20.6 17.6 14.6 11.7 8.7 70° 80° 25° 30° 40° 50.2 55.0 30.4 32.6 36.8 107.2 110.7 97.5 99.1 102.3 3.41 3.52 3.29 3.35 3.46 50° 53.5 32.6 0.60 1.49 58.9 28.0 50° 75° 41.0 105.4 3.58 60° 51.2 31.8 0.62 1.87 57.9 24.9 70° 48.9 31.1 0.64 2.25 57.0 21.7 80° 85° DB 71° WB 46.5 30.3 0.65 2.62 56.0 18.6 90° 44.2 29.5 0.67 3.00 55.1 15.5 60° 70° 80° 45.9 50.8 55.6 109.0 112.6 116.2 3.71 3.83 3.95 100° 41.9 28.7 0.68 3.38 54.1 12.4 Heat of Absorption COP (MBtuH) 20.7 3.2 22.7 3.3 26.6 3.6 30.6 3.9 35.2 4.2 39.7 4.5 44.3 4.8 20.1 3.0 22.0 3.2 25.9 3.4 29.7 3.7 34.1 4.0 38.6 4.3 43.0 4.6 19.5 2.7 21.4 2.9 25.1 3.1 28.8 3.4 33.1 3.6 37.4 3.9 41.7 4.1 110° 39.5 27.9 0.70 3.76 53.2 9.3 Form No. S3419-0521 Supersedes S3419-617 Page 7 of 26 Water Coil Pressure Drop (Fresh Water) Model GPM 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 QW2S & QW3S PSID Ft. Hd. 0.1 0.23 0.5 1.15 1.2 2.77 1.7 3.92 2.3 5.31 3.1 7.15 4.1 9.46 QW4S PSID Ft. Hd. 0.9 1.4 2.3 3.2 4.1 5.1 6.1 7.1 8.2 9.4 10.6 2.08 3.23 5.31 7.38 9.46 11.77 14.07 16.38 18.92 21.69 24.45 QW5S PSID Ft. Hd. 2 4.61 2.5 5.77 3.2 7.38 3.9 9.00 4.7 10.84 5.5 12.69 6.4 14.76 7.3 16.84 8.1 18.69 9 20.76 9.9 22.84 NOTE: For pump options 3, 4 and 5 add 1.5 head to Table values as allowance for QW*S internal piping. Additional feet head allowance for external piping to loop must be included and determined by others. Required Flow Rates for Water Loop Installations Flow rate required GPM fresh water QW2S 6.1 QW3S 8.6 QW4S 11.5 QW5S 13.7 Required Flow Rates for Ground Loop Installations Flow rate required GPM Methanol, Propylene Glycol or Ethanol j j See Antifreeze table below. QW2S 7 QW3S 8 QW4S 9 QW5S 11 Antifreeze Percentages by Volume for Ground Loop Installations j Type Minimum Temperature for Freeze Protection 10°F (-12.2°C) 15°F (-9.4°C) 20°F (-6.7°C) 25°F (-3.9°C) Methanol 25% 21% 16% 10% Ethanol k 29% 25% 20% 14% 100% USP Food Grade Propylene Glycol 27% 24% 20% 13% j Loop antifreeze protection must be determined based on loop design and geographic location. k Must not be denatured with any petroleum based product. Unit Charge Rates UNIT QW2S2 - High Efficiency Step Capacity Geothermal Indoor Heat Pump QW3S2 - High Efficiency Step Capacity Geothermal Indoor Heat Pump QW4S2 - High Efficiency Step Capacity Geothermal Indoor Heat Pump QW5S2 - High Efficiency Step Capacity Geothermal Indoor Heat Pump Std. Unit Lbs. 6.1875 Dehum. Units - Lbs. 6.1875 6.00 6.00 7.0625 7.0625 7.625 7.625 Form No. S3419-0521 Supersedes S3419-617 Page 8 of 26 Ventilation System Packages -- Optional Q-TEC models are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. All ventilation packages are factory installed. If no option is ordered, the ventilation intake and exhaust are sealed with a blank-off plate. NOTE: A ventilation wall sleeve QWVS42 with outdoor louver grille is required for all installations that intend to utilize one of the built-in ventilation options of the QW*S Series heat pumps. If a ventilation option is not to be utilized, do not order ventilation wall sleeve. COMMERCIAL ROOM VENTILATOR (Option V) OPTIONAL The built-in commercial room ventilator is internally mounted and allows outside ventilation air, up to 50% of the total airflow rating of the unit, to be introduced through the ventilation louver grille. It includes a built-in exhaust air damper. Spring return on power loss or deactivation. The commercial room ventilator (CRV) is a simple and innovative approach to improving the indoor air quality by providing fresh air intake and exhaust capability through the CRV. The damper can be easily adjusted to control the amount of fresh air supplied into the building. The CRV can be controlled by indoor blower operation or field controlled based on room occupancy. Complies with ANSI/ASHRAE Standard 62.1 "Ventilation for Acceptable Indoor Air Quality". COMMERCIAL ROOM VENTILATOR (Option W) OPTIONAL The built-in commercial room ventilator is internally mounted and allows outside ventilation air, up to 50% of the total airflow rating of the unit, to be introduced through the ventilation louver grille. It includes a built-in exhaust air damper. Spring return on power loss or deactivation. The commercial room ventilator (CRV) is a simple and innovative approach to improving the indoor air quality by providing fresh air intake and exhaust capability through the CRV. The damper can be easily adjusted to control the amount of fresh air supplied into the building. The CRV can be controlled by indoor blower operation or field controlled based on room occupancy. Complies with ANSI/ASHRAE Standard 62.1 "Ventilation for Acceptable Indoor Air Quality". Option W has 0 - 10 VDC actuator for DDC control by others. ENERGY RECOVERY VENTILATOR (Option R) OPTIONAL The energy recovery ventilator (ERV) is a highly innovative approach to meeting indoor air quality ventilation requirements as established by ANSI/ASHRAE Standard 62.1. The ERV is internally mounted and allows up to 450 CFM (depending upon speed setting) of fresh air and exhaust through the unit while maintaining superior indoor comfort and humidity levels. In most cases this can be accomplished without increasing equipment sizing or operating costs. Heat transfer efficiency is up to 64% during summer and 79% during winter conditions. The ERV consists of a unique "rotary energy recovery cassette" that provides effective sensible and latent heat transfer capabilities during summer and winter conditions. Various control schemes are addressed including limiting ventilation during building occupancy only. The ERV has a filter for the exhaust air to keep the rotary wheels clean and free of any debris introduced through the room return air grille. The intake and exhaust rates can be independently selected. Factory set on medium intake and low exhaust. Intake and exhaust air paths have shut-off dampers to eliminate the ingress of outside air when ventilation system is off. ENERGY RECOVERY VENTILATOR (Option S) OPTIONAL The energy recovery ventilator (ERV) is a highly innovative approach to meeting indoor air quality ventilation requirements as established by ANSI/ASHRAE Standard 62.1. The ERV is internally mounted and allows up to 450 CFM (depending upon speed setting) of fresh air and exhaust through the unit while maintaining superior indoor comfort and humidity levels. In most cases this can be accomplished without increasing equipment sizing or operating costs. Heat transfer efficiency is up to 64% during summer and 79% during winter conditions. The ERV consists of a unique "rotary energy recovery cassette" that provides effective sensible and latent heat transfer capabilities during summer and winter conditions. Various control schemes are addressed including limiting ventilation during building occupancy only. The ERV has a filter for the exhaust air to keep the rotary wheels clean and free of any debris introduced through the room return air grille. The intake and exhaust rates can be independently selected. Factory set on medium intake and low exhaust. Intake and exhaust air paths have shut-off dampers to eliminate the ingress of outside air when ventilation system is off. Equipped with Intelligent Frost Control that cycles the ventilation air intake damper closed for 4 minutes out of every 32 minutes of ERV operation when the outdoor air is below 10°F. This sequence allows the ERV to operate with zero outdoor air intake and allows conditioned room air to defrost any accumulated frost if present on the cassette wheels. ENERGY RECOVERY VENTILATOR (Option T) OPTIONAL The energy recovery ventilator (ERV) is a highly innovative approach to meeting indoor air quality ventilation requirements as established by ANSI/ASHRAE Standard 62.1. The ERV is internally mounted and allows up to 450 CFM (depending upon speed setting) of fresh air and exhaust through the unit while maintaining superior indoor comfort and humidity levels. In most cases this can be accomplished without increasing equipment sizing or operating costs. Heat transfer efficiency is up to 64% during summer and 79% during winter conditions. The ERV consists of a unique "rotary energy recovery cassette" that provides effective sensible and latent heat transfer capabilities during summer and winter conditions. Various control schemes are addressed including limiting ventilation during building occupancy only. The ERV has a filter for the exhaust air to keep the rotary wheels clean and free of any debris introduced through the room return air grille. The intake and exhaust rates can be independently selected. Factory set on medium intake and low exhaust. Intake and exhaust air paths have shut-off dampers to eliminate the ingress of outside air when ventilation system is off. Additional controls to permit lower ventilation intake airflow (105 - 225 CFM based on selected intake blower speed and room tightness) and controlled by an occupancy signal, and then can increase to maximum of 450 CFM and controlled by CO2 input signal. ELECTRICAL SPECIFICATIONS MODEL RATED VOLTS & PHASE NO. FIELD POWER CIRCUITS l MINIMUM CIRCUIT AMPACITY j MAXIMUM EXTERNAL FUSE OR CIRCUIT BREAKER k FIELD POWER WIRE SIZE k GROUND WIRE SIZE QW2S2-A0Z 230/208-1 1 19 30 10 10 QW2S2-B0Z 230/208-3 1 12 20 12 12 QW2S2-C0Z 460-3 1 7.5 15 14 14 QW3S2-A0Z 230/208-1 1 25 40 8 10 QW3S2-B0Z 230/208-3 1 20 30 10 10 QW3S2-C0Z 460-3 1 11 15 14 14 QW4S2-A0Z 230/208-1 1 33 50 8 10 QW4S2-B0Z 230/208-3 1 24 35 8 10 QW4S2-C0Z 460-3 1 13 20 12 14 QW5S2-A0Z 230/208-1 1 41 60 6 10 QW5S2-B0Z 230/208-3 1 28 40 8 10 QW5S2-C0Z 460-3 1 13 20 12 12 j Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. k Based on 75°C copper wire. All wiring must conform to the National Electrical Code and all local codes. l These "Minimum Circuit Ampacity" values are to be used for sizing the field power conductors. Refer to the National Electrical Code (latest revision) article 310 for power conductor sizing. Form No. S3419-0521 Supersedes S3419-617 Page 9 of 26 450 400 F 350 R E 300 S H FM C 250 IR A A I ESH FR 200 R 150 C F 100 M 50 0 QW2S CRV AIRFLOW VS. DAMPER POSITION 5 10 15 20 25 30 DAMPER POSITION Full Load Part Load Blower Only 550 500 F 450 R 400 E S 350 H FM C IR 300 AA I ESH 250 R FR 200 C 150 F M 100 50 0 QW3S CRV AIRFLOW VS. DAMPER POSITION Rated Full Load Optional Full Load Part Load Blower Only 5 10 15 20 25 30 DAMPER POSITION Form No. S3419-0521 Supersedes S3419-617 Page 10 of 26 600 550 500 F R 450 E 400 S H FM350 C IR A 300 A I ESH FR 250 R 200 C 150 F M 100 50 0 QW4S CRV AIRFLOW VS. DAMPER POSITION Full Load Optional Full Load Part Load Blower Only 5 10 15 20 25 30 DAMPER POSITION 650 600 550 F R 500 E 450 S H FM400 A C IR A 350 I ESH 300 R FR 250 C 200 F 150 M 100 50 0 QW5S CRV AIRFLOW VS. DAMPER POSITION Full Load Optional Full Load Part Load Blower Only 5 10 15 20 25 30 DAMPER POSITION Form No. S3419-0521 Supersedes S3419-617 Page 11 of 26 Energy Recovery Ventilator Performance Tables SUMMER COOLING PERFORMANCE (INDOOR DESIGN CONDITIONS 75°DB/62°WB) Ambient O.D. VENTILATION RATE 450 CFM 65% EFFICIENCY VENTILATION RATE 375 CFM 66% EFFICIENCY VENTILATION RATE 300 CFM 67% EFFICIENCY DB/WB F VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL 75 21465 14580 6884 13952 9477 4475 17887 12150 5737 11805 8018 3786 14310 9720 4590 9587 6512 3075 105 70 14580 14580 0 9477 9477 0 12150 12150 0 8018 8018 0 9720 9720 0 6512 6512 0 65 14580 14580 0 9477 9477 0 12150 12150 0 8018 8018 0 9720 9720 0 6512 6512 0 80 31590 12150 19440 20533 7897 12635 26325 10125 16200 17374 6682 10692 21060 8100 12960 14110 5427 8683 75 21465 12150 9314 13952 7897 6054 17887 10125 7762 11805 6682 5123 14310 8100 6210 9587 5427 4160 100 70 12352 12150 202 8029 7897 131 10293 10125 168 6793 6682 111 8235 8100 135 5517 5427 90 65 12150 12150 0 7897 7897 0 10125 10125 0 6682 6682 0 8100 8100 0 5427 5427 0 60 12150 12150 0 7897 7897 0 10125 10125 0 6682 6682 0 8100 8100 0 5427 5427 0 80 31590 9720 21870 20533 6318 14215 26325 8100 18225 17374 5345 12028 21060 6480 14580 14110 4341 9768 75 21465 9720 11744 13952 6318 7634 17887 8100 9787 11805 5345 6459 14310 6480 7830 9587 4341 5246 95 70 12352 9720 2632 8029 6318 1711 10293 8100 2193 6793 5345 1447 8235 6480 1755 5517 4341 1175 65 9720 9720 0 6318 6318 0 8100 8100 0 5345 5345 0 6480 6480 0 4341 4341 0 60 9720 9720 0 6318 6318 0 8100 8100 0 5345 5345 0 6480 6480 0 4341 4341 0 80 31590 7290 24300 20533 4738 15794 26325 6075 20250 17374 4009 13365 21060 4860 16200 14110 3256 10854 75 21465 7290 14175 13952 4738 9213 17887 6075 11812 11805 4009 7796 14310 4860 9450 9587 3256 6331 90 70 12352 7290 5062 8029 4738 3290 10293 6075 4218 6793 4009 2784 8235 4860 3375 5517 3256 2261 65 7290 7290 0 4738 4738 0 6075 6075 0 4009 4009 0 4860 4860 0 3256 3256 0 60 7290 7290 0 4738 4738 0 6075 6075 0 4009 4009 0 4860 4860 0 3256 3256 0 80 31590 4860 26730 20533 3159 17374 26325 4050 22275 17374 2672 14701 21060 3240 17820 14110 2170 11939 75 21465 4860 16605 13952 3159 10793 17887 4050 13837 11805 2672 9132 14310 3240 11070 9587 2170 7416 85 70 12352 4860 7492 8029 3159 4870 10293 4050 6243 6793 2672 4120 8235 3240 4995 5517 2170 3346 65 4860 4860 0 3159 3159 0 4050 4050 0 2672 2672 0 3240 3240 0 2170 2170 0 60 4860 4860 0 3159 3159 0 4050 4050 0 2672 2672 0 3240 3240 0 2170 2170 0 75 21465 2430 19035 13952 1579 12372 17887 2025 15862 11805 1336 10469 14310 1620 12690 9587 1085 8502 70 12352 2430 9922 8029 1579 6449 10293 2025 8268 6793 1336 5457 8235 1620 6615 5517 1085 4432 80 65 4252 2430 1822 2764 1579 1184 3543 2025 1518 2338 1336 1002 2835 1620 1215 1899 1085 814 60 2430 2430 0 1579 1579 0 2025 2025 0 1336 1336 0 1620 1620 0 1085 1085 0 70 12352 0 12352 8029 0 8029 10293 0 10293 6793 0 6793 8235 0 8235 5517 0 5517 75 65 4252 0 4252 2764 0 2764 3543 0 3543 2338 0 2338 2835 0 2835 1899 0 1899 60 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 WINTER HEATING PERFORMANCE (INDOOR DESIGN CONDITIONS 70°F DB) Ambient O.D. 450 CFM 80% EFFICIENCY DB/°F VLT HRS VLS 65 2430 1944 486 60 4860 3888 972 55 7290 5832 1458 50 9720 7776 1944 45 12150 9720 2430 40 14580 11664 2916 35 17010 13608 3402 30 19440 15552 3888 25 21870 17496 4374 20 24300 19440 4860 15 26730 21384 5346 10 29160 23328 5832 5 31590 25272 6318 0 34020 27216 6804 -5 36450 29160 7290 -10 38880 31104 7776 Form No. S3419-0521 Supersedes S3419-617 Page 12 of 26 VENTILATION RATE 375 CFM 81% EFFICIENCY VLT HRS VLS 2025 1640 385 4050 3280 770 6075 4920 1154 8100 6561 1539 10125 8201 1924 12150 9841 2309 14175 11481 2693 16200 13122 3078 18225 14762 3463 20250 16402 3848 22275 18042 4232 24300 19683 4617 26325 21323 5002 28350 22964 5387 30375 24604 5771 32400 26244 6156 300 CFM 82% EFFICIENCY VLT HRS VLS 1620 1328 292 3240 2656 583 4860 3985 875 6480 5313 1166 8100 6642 1458 9720 7970 1750 11340 9298 2041 12960 10627 2333 14580 11955 2624 16200 13284 2916 17820 14612 3208 19440 15941 3499 21060 17269 3791 22680 18598 4082 24300 19926 4374 25920 21254 4666 NOTE: Sensible performance only is shown for winter application. LEGEND: VLT = Ventilation Load - Total VLS = Ventilation Load - Sensible VLL = Ventilation Load - Latent HRT = Heat Recovery - Total HRS = Heat Recovery - Sensible HRL = Heat Recovery - Latent WVL = Winter Ventilation Load WHR = Winter Heat Recovery BTU/HR Optional Hot Water Coil Performance Heating Capacity @ 180°F Water & 70°F Return Air 100000 90000 80000 70000 60000 50000 1.5GPM 2GPM 4GPM 6GPM 8GPM 10GPM 40000 30000 700 800 900 1000 1100 1200 1300 1400 1500 CFM Hot Water Coil Correction Factors Ennterinng Air Temp (F) 50 55 60 65 70 75 80 100 0.455 0.409 0.363 0.318 0.272 0.227 0.182 110 0.545 0.500 0.455 0.409 0.363 0.318 0.272 120 0.636 0.591 0.545 0.500 0.455 0.409 0.363 130 0.727 0.682 0.636 0.591 0.545 0.500 0.455 Ennterinng Water Temperature (F) 140 150 160 0.818 0.909 1.000 0.773 0.864 0.955 0.727 0.818 0.909 0.682 0.773 0.864 0.636 0.727 0.818 0.591 0.682 0.773 0.545 0.636 0.727 170 1.091 1.045 1.000 0.955 0.909 0.864 0.818 180 1.182 1.136 1.091 1.045 1.000 0.955 0.909 190 1.273 1.227 1.182 1.136 1.091 1.045 1.000 200 1.364 1.318 1.273 1.227 1.182 1.136 1.091 Form No. S3419-0521 Supersedes S3419-617 Page 13 of 26 Installation Overview of Ventilation Wall Sleeve Exterior Wall View NOTE: OPENING DIMENSIONS ARE ± .250 29.750 35.250 33.000 MIS-1612 NOTE: Wall opening and wall sleeve required only when one of the ventilation options is utilized. Installations not utilizing any ventilation option can be made in any interior space accessible to electrical supply, water supply system and condensate drain. QW2S, QW3S - 42.000" QW4S, QW5S - 48.000" SUPPLY AIR OPTIONAL FREE (X) BLOW PLENUM BOX HIGH VOLTAGE ELECTRICAL ENTRANCE (TOP-REAR-SIDE) RETURN AIR 90" 104" BOTTOM TRIM PIECE Form No. S3419-0521 Supersedes S3419-617 Page 14 of 26 14" to 5" WALL SLEEVE VENTILATION AIR DIVIDER 18 9/16" 33 7/8" 28 7/8" 35" 29 1/2" 33" 17 9/16" 6 1/8" MIST ELIMINATOR PERMANENT ROLLERS LOW VOLTAGE ELECTRICAL ACCESS (TOP-SIDE) CIRCUIT BREAKER, ROTARY, OR TOGGLE DISCONNECT AND LOCKING COVER MIS-2739 B Unit and Wall Sleeve Opening Installation Overview Unit Installed with Free Blow Plenum Box Dimensions of Basic Unit for Architectural and Installation Requirements (Nominal) SUPPLY AIR OPENING 2 7/16" 10" 20 3/8" (DUCT SIZE) 2 1/16" 1 3/4" TOP VIEW (SHOWN WITHOUT FREEBLOW PLENUM) "E" (DUCT SIZE) "A" "B" "C" 2 15/16" UNIT DIM. "A" QW2S, QW3S 8 5/8" QW4S, QW5S 8 3/4" DIM. "B" DIM. "C" DIM. "D" DIM. "E" 42" 30" 43" 25" 48" 40" 49" 30" (OPTIONAL) HIGH VOLTAGE ELECTRICAL ENTRANCE 6 3/4" LOW VOLTAGE ELECTRICAL ENTRANCE 7/8" (OPTIONAL) LOW VOLTAGE 3 3/16" ELECTRICAL ENTRANCE (OPTIONAL) LOW VOLTAGE ELECTRICAL ENTRANCE 1 1/8" FREEBLOW PLENUM BOX (OPTIONAL) (OPTIONAL) HIGH VOLTAGE ELECTRICAL ENTRANCE 1 15/16" (OPTIONAL) HIGH VOLTAGE ELECTRICAL ENTRANCE 14" SUPPLY AIR GRILLE 1 11/16" 11 3/4" 16 5/8" (OPTIONAL) THERMOSTAT (OPTIONAL) CO2 SENSOR 37 1/8" FILTER 104" ACCESS DOOR 36 1/16" CONDENSER DOOR 3 3/4" CIRCUIT BREAKER ACCESS AND LOCKING COVER RETURN AIR GRILLE 15 5/8" 68 3/4" "C" 36 7/8" 3 3/8" 3 3/8" 3 1/16" ACCESS 5 7/16" FOR FLUID CONNECTION FOR DORFC PUMP APPLICATION FACTORY CONNECTED CONDENSATE DRAIN CONNECTION 3/4" PVC MALE ADAPTER 3" 11 1/2" 30 7/8" 6 7/8" 8" 19" VENT EXHAUST VENT INTAKE 1" BETWEEN OPENINGS 6.00" 4.625" 34 1/4" TO FLOOR LEVEL 20" "D" FRONT VIEW RIGHT SIDE VIEW FLUID CONNECTION POINTS FOR FACTORY INSTALLED PUMP OPTIONS 3, 4, OR 5 (INLET ON LEFT, BACK VIEW OUTLET ON RIGHT AS VIEWED FROM BACK OF UNIT) MIS-2737 D Form No. S3419-0521 Supersedes S3419-617 Page 15 of 26 Supply Duct Connections for Ducted Installations MODEL "A" "B" QW2S, QW3S 10" 25" QW4S, QW5S 10" 30" "A" "B" SUPPLY DUCT TO BE FIELD SUPPLIED ATTACHMENT SCREWS TO BE FIELD SUPPLIED ROOM SIDE OF QW UNIT DUCT FLANGE PROVIDED WITH UNIT MIS-2742 A Form No. S3419-0521 Supersedes S3419-617 Page 16 of 26 QRS-Series Sound Plenum The QRS3 - QRS5 Series Sound Plenum has been designed for use with QW*S units. Installation is quick and easy with removal/replacement of six existing screws from the unit cabinet. Once installed the sound plenum enhances the current quiet operation of the Q-TEC Series units, and the hinged door with cam locks (one lockable) provides easy access to the basic Q-TEC system. Model selection is based on equipment cabinet size and finish. Sound Plenum Part Number Plenum Finish QRS3-X QRS3-4 QRS3-V Painted Steel - Beige Painted Steel - Buckeye Gray Texture Vinyl j QRS5-X QRS5-4 QRS5-V Painted Steel - Beige Painted Steel - Buckeye Gray Texture Vinyl j j Front Panels Slate Finish; Side Panels Gray Paint. Compatible with Equipment Selection QW2S & QW3S QW4S & QW5S 8.250" "A" UNIT QRS3 QRS5 DIM. "A" 42" 48" Features: · Compatible with new or existing QWS units. · Removable cam latch hinged doors, with center latch lockable. · Easy unit service design. · Sound absorbing insulation. · Reduces equipment operating levels and general muffling of basic unit operation. Actual sound reduction may vary depending upon site variables. QRS SOUND PLENUM QW*S UNIT MIS-2794 Form No. Supersedes Page MIS-2267 S3419-0521 S3419-617 17 of 26 QRASP Series Return Air Sound Plenum The QRASP3 - QRASP5 Series Sound Plenum has been designed for use with sound absorbing side panels. It is similar in design to the QSP Sound Plenum, but also incorporates additional sound attenuation panels on both sides as shown. Installation is quick and easy with removal/replacement of six existing screws from the unit cabinet. Once installed the sound plenum enhances the current quiet operation of the Q-TEC Series units, and the hinged door with cam locks (one lockable) provides easy access to the basic Q-TEC system. Model selection is based on equipment cabinet size and finish. Sound Plenum Part Number QRASP3-X QRASP3-4 QRASP3-V QRASP5-X QRASP5-4 QRASP5-V Plenum Finish Painted Steel - Beige Painted Steel - Buckeye Gray Texture Vinyl j Painted Steel - Beige Painted Steel - Buckeye Gray Texture Vinyl j j Front Panels Slate Finish; Side Panels Gray Paint. Compatible with Equipment Selection QW2S & QW3S QW4S & QW5S Features: · Compatible with new or existing QW*S units. · Removable cam latch hinged doors, with center latch lockable. · Easy unit service design. · Incorporates additional sound absorbing side panels. · Sound absorbing insulation. · Reduces equipment operating levels and general muffling of basic unit operation. Actual sound reduction may vary depending upon site variables. 7" OBSTRUCTION UNIT DIM A QRASP3 55 13/16" QRASP5 61 13/16" 7" OBSTRUCTION 12" MINIMUM 8 1/4" "A" 12" MINIMUM 27 11/16" MIS-2785 A Form No. S3419-0521 Supersedes S3419-617 Page 18 of 26 91 1/8" 90" 7 1/4" MIS-2735 A Bard QW2S2 Series Q-TEC Sound Data Matrix (dBA @ 10 feet) Duct Free Supply Air Treatment Return Air Treatment Vent Option CRV Ventilation Only Part Load QPBS42 Return Grille 450 CFM 33.8 38.0 QPBS42 QRS Plenum 450 CFM 32.7 37.1 QPBS42 QRASPS Plenum 450 CFM 32.0 36.0 Duct Free Silencer QRASPS Plenum 450 CFM 30.4 35.6 Ducted Return Grille 450 CFM 31.8 38.3 Full Load Integrated dBA Sound Power Full Load Outdoor @ 10 Feet Vent Option ERV Blower Only ERV Off 34.5 300 CFM 39.3 375 CFM 42.9 39.3 36.4 53.5 36.9 450 CFM 48.1 38.0 35.4 ERV Off 33.0 300 CFM 36.1 375 CFM 39.0 450 CFM 45.0 37.7 34.6 ERV Off 31.1 300 CFM 33.6 375 CFM 35.0 450 CFM 41.8 36.5 33.6 49.9 ERV Off 30.4 300 CFM 32.8 375 CFM 34.7 450 CFM 43.8 38.2 35.7 51.9 36.9 ERV Off 31.6 300 CFM 39.1 375 CFM 42.9 450 CFM 47.9 Part Load 38.2 41.5 43.7 47.4 39.4 40.8 41.6 42.9 37.1 38.2 38.3 41.3 34.5 35.8 36.9 42.9 36.5 40.8 43.7 47.4 Full Load 40.3 42.5 44.3 48.0 39.4 40.6 41.8 44.3 38.3 38.7 39.4 42.9 35.5 36.4 38.3 43.7 37.6 40.7 43.4 48.7 Integrated dBA 37.1 40.6 43.4 47.9 36.8 38.6 40.3 44.4 35.0 36.3 37.0 41.9 32.9 34.5 36.1 43.6 34.7 39.9 43.2 47.9 Sound Power Full Load 60.3 56.2 Outdoor @ 10 Feet 60.8 1 Integrated values calculated per ANSI/ASA S12.60-2009/Part 2, Section 5.2.2.1, Table 2 Triple Mode Type 3 HVAC System Duty Cycles: Ventilation 58%, Part Load 25%, Full Load 17% 2 Integrated Sound Vales are also applicable for use in learning spaces for CHPS and LEED schools; EQ Prerequisite 3 - Minimum Acoustical Performance, OPTION 1. Using methods prescribed in prescribed in ANSI S12.60, classroom must achieve a maximum background noise level of 45 dBA. 3 All data recorded at rated GPM per Bard product specifications. Results Referenced Were Recorded In The Bard Manufacturing Company, Inc. Sound Lab Facility Actual Field Application Results May Vary With Classroom Design and Construction Methods 11/4/2013 ERV Off 30.8 37.6 37.0 34.8 Ducted Ducted QRS Plenum 450 CFM 30.7 37.2 37.8 34.8 300 CFM 35.4 38.6 38.1 36.9 375 CFM 38.4 40.7 40.3 39.4 450 CFM 43.7 43.3 45.7 44.0 ERV Off 29.8 36.9 36.3 34.0 35.9 Ducted QRASPS Plenum 450 CFM 30.0 35.9 36.6 33.7 52.9 300 CFM 32.5 36.0 36.2 34.4 375 CFM 35.2 38.2 38.3 36.7 450 CFM 41.8 42.8 43.3 42.3 56.9 53.7 Bard QW2S2 Series Q-TEC Sound Data Matrix (dBA @ 5 feet) Duct Free Supply Air Treatment Return Air Treatment Vent Option CRV Ventilation Only Part Load QPBS42 Return Grille 450 CFM 35.5 38.9 QPBS42 QRS Plenum 450 CFM 33.9 38.8 QPBS42 QRASPS Plenum 450 CFM 32.8 36.4 Duct Free Silencer QRASPS Plenum 450 CFM 31.7 36.3 Ducted Return Grille 450 CFM 33.8 39.1 Full Load Integrated dBA Sound Power Full Load Outdoor @ 10 Feet Vent Option ERV Blower Only ERV Off 35.8 300 CFM 41.8 375 CFM 46.1 39.8 37.5 450 CFM 51.3 39.7 36.9 ERV Off 33.9 300 CFM 37.1 375 CFM 40.7 450 CFM 46.1 38.6 35.4 ERV Off 32.4 300 CFM 35.0 375 CFM 36.6 450 CFM 43.8 38.0 34.8 ERV Off 31.7 300 CFM 34.1 375 CFM 36.3 450 CFM 44.8 40.3 37.2 ERV Off 33.5 300 CFM 41.8 375 CFM 46.3 450 CFM 50.8 Part Load 39.8 43.1 46.5 50.7 40.9 41.9 43.7 44.1 37.2 38.0 39.2 43.6 34.9 36.0 37.8 44.2 38.4 43.0 46.7 51.2 Full Load 41.0 43.9 46.8 50.8 40.7 41.5 43.2 45.5 38.8 39.1 40.0 44.4 36.8 37.5 39.3 45.0 39.3 43.1 46.7 50.8 Integrated dBA 38.3 42.6 46.3 51.1 38.1 39.7 42.1 45.6 35.6 36.8 38.1 43.9 33.9 35.4 37.3 44.7 36.5 42.4 46.5 50.9 Sound Power Full Load Outdoor @ 10 Feet 1 Integrated values calculated per ANSI/ASA S12.60-2009/Part 2, Section 5.2.2.1, Table 2 Triple Mode Type 3 HVAC System Duty Cycles: Ventilation 58%, Part Load 25%, Full Load 17% 2 Integrated Sound Vales are also applicable for use in learning spaces for CHPS and LEED schools; EQ Prerequisite 3 - Minimum Acoustical Performance, OPTION 1. Using methods prescribed in prescribed in ANSI S12.60, classroom must achieve a maximum background noise level of 45 dBA. 3 All data recorded at rated GPM per Bard product specifications. Results Referenced Were Recorded In The Bard Manufacturing Company, Inc. Sound Lab Facility Actual Field Application Results May Vary With Classroom Design and Construction Methods 11/4/2013 ERV Off 31.9 39.7 38.6 36.5 Ducted Ducted QRS Plenum 450 CFM 31.8 40.0 40.2 37.1 300 CFM 36.4 40.8 39.7 38.5 375 CFM 40.1 42.3 42.1 41.1 450 CFM 44.9 44.7 44.8 44.8 ERV Off 30.8 36.9 37.2 34.5 Ducted QRASPS Plenum 450 CFM 30.7 37.4 37.8 34.9 300 CFM 33.9 36.6 37.2 35.4 375 CFM 36.8 38.9 39.2 37.9 450 CFM 43.8 44.5 44.7 44.1 Form No. S3419-0521 Supersedes S3419-617 Page 19 of 26 Form No. S3419-0521 Supersedes S3419-617 Page 20 of 26 Bard QW3S2 Series Q-TEC Sound Data Matrix (dBA @ 10 feet) Duct Free Supply Air Treatment Return Air Treatment Vent Option CRV Ventilation Only Part Load QPBS42 Return Grille 450 CFM 35.4 41.4 QPBS42 QRS Plenum 450 CFM 33.2 39.0 QPBS42 QRASPS Plenum 450 CFM 32.9 38.4 Duct Free Silencer QRASPS Plenum 450 CFM 30.9 38.5 Ducted Return Grille 450 CFM 31.3 41.5 Full Load Integrated dBA Sound Power Full Load Outdoor @ 10 Feet Vent Option ERV Blower Only ERV Off 33.3 300 CFM 40.7 375 CFM 45.0 43.8 39.8 55.8 40.0 450 CFM 49.5 41.5 37.5 ERV Off 32.4 300 CFM 37.0 375 CFM 39.9 450 CFM 43.9 41.0 37.0 ERV Off 31.3 300 CFM 33.4 375 CFM 35.7 450 CFM 41.7 40.1 36.3 52.4 ERV Off 29.7 300 CFM 32.5 375 CFM 34.9 450 CFM 41.4 42.1 38.5 54.1 ERV Off 31.5 300 CFM 39.7 375 CFM 44.6 450 CFM 48.8 ERV Off 30.4 Part Load 44.5 46.6 47.6 50.4 38.8 40.5 42.1 45.4 39.1 38.7 39.6 43.0 37.0 36.8 38.0 42.7 38.2 41.9 44.9 49.2 37.2 Full Load 42.9 44.4 46.8 50.8 40.1 41.2 42.5 45.9 39.7 39.8 40.1 43.5 38.3 38.4 39.1 42.9 40.9 43.4 45.8 49.6 38.8 Integrated dBA 40.6 43.6 46.1 50.0 36.7 39.0 48.7 44.7 36.4 36.8 37.9 42.4 34.7 35.3 36.8 42.0 36.6 41.1 44.9 49.0 35.1 Sound Power Full Load 62.2 55.6 65.3 Outdoor @ 10 Feet 39.6 53.8 1 Integrated values calculated per ANSI/ASA S12.60-2009/Part 2, Section 5.2.2.1, Table 2 Triple Mode Type 3 HVAC System Duty Cycles: Ventilation 58%, Part Load 25%, Full Load 17% 2 Integrated Sound Vales are also applicable for use in learning spaces for CHPS and LEED schools; EQ Prerequisite 3 - Minimum Acoustical Performance, OPTION 1. Using methods prescribed in prescribed in ANSI S12.60, classroom must achieve a maximum background noise level of 45 dBA. 3 All data recorded at rated GPM per Bard product specifications. Results Referenced Were Recorded In The Bard Manufacturing Company, Inc. Sound Lab Facility Actual Field Application Results May Vary With Classroom Design and Construction Methods 10/28/2013 Ducted Ducted QRS Plenum 450 CFM 30.9 38.2 39.6 35.9 300 CFM 375 CFM 450 CFM 36.1 39.9 44.6 38.2 40.4 45.3 40.1 41.6 45.4 37.6 40.4 44.9 ERV Off 28.6 36.8 38.0 34.3 Ducted QRASPS Plenum 450 CFM 29.7 37.3 38.8 35.0 50.2 300 CFM 32.4 36.5 38.4 35.2 375 CFM 34.8 37.7 39.3 36.7 450 CFM 40.4 42.6 42.0 41.3 54.1 Bard QW3S2 Series Q-TEC Sound Data Matrix (dBA @ 5 feet) Duct Free Supply Air Treatment Return Air Treatment Vent Option CRV Ventilation Only Part Load QPBS42 Return Grille 450 CFM 36.5 42.2 QPBS42 QRS Plenum 450 CFM 34.3 39.8 QPBS42 QRASPS Plenum 450 CFM 33.7 39.6 Duct Free Silencer QRASPS Plenum 450 CFM 32.0 40.4 Ducted Return Grille 450 CFM 33.0 42.0 Full Load Integrated dBA Sound Power Full Load Outdoor @ 10 Feet Vent Option ERV Blower Only ERV Off 34.6 300 CFM 43.0 375 CFM 48.2 45.3 41.0 450 CFM 52.8 42.5 38.4 ERV Off 33.4 300 CFM 37.7 375 CFM 41.9 450 CFM 45.7 42.0 38.0 ERV Off 32.2 300 CFM 34.2 375 CFM 37.4 450 CFM 42.1 41.0 37.6 ERV Off 31.0 300 CFM 33.6 375 CFM 36.2 450 CFM 42.1 44.0 39.7 ERV Off 33.1 300 CFM 42.3 375 CFM 48.7 450 CFM 52.5 ERV Off 31.5 Part Load 46.2 48.0 50.5 53.6 39.9 41.2 43.2 46.7 41.7 40.8 41.5 46.0 39.6 39.4 40.3 45.7 39.9 44.4 48.6 52.9 39.0 Full Load 44.4 46.4 49.5 53.8 41.1 41.2 43.9 47.2 41.0 41.0 41.5 45.4 39.9 40.1 40.5 44.8 42.9 46.2 49.6 53.4 40.2 Integrated dBA 42.2 45.4 49.1 53.2 37.7 39.5 42.6 46.2 38.3 38.2 39.6 44.0 36.7 37.2 38.5 43.8 38.4 43.8 48.8 52.8 36.6 Sound Power Full Load Outdoor @ 10 Feet 1 Integrated values calculated per ANSI/ASA S12.60-2009/Part 2, Section 5.2.2.1, Table 2 Triple Mode Type 3 HVAC System Duty Cycles: Ventilation 58%, Part Load 25%, Full Load 17% 2 Integrated Sound Vales are also applicable for use in learning spaces for CHPS and LEED schools; EQ Prerequisite 3 - Minimum Acoustical Performance, OPTION 1. Using methods prescribed in prescribed in ANSI S12.60, classroom must achieve a maximum background noise level of 45 dBA. 3 All data recorded at rated GPM per Bard product specifications. Results Referenced Were Recorded In The Bard Manufacturing Company, Inc. Sound Lab Facility Actual Field Application Results May Vary With Classroom Design and Construction Methods 10/28/2013 Ducted Ducted QRS Plenum 450 CFM 32.7 39.5 41.0 37.4 300 CFM 375 CFM 450 CFM 37.3 41.6 46.0 39.8 42.0 46.8 41.1 43.0 46.7 38.9 42.0 46.3 ERV Off 29.8 39.2 39.5 36.2 Ducted QRASPS Plenum 450 CFM 30.7 39.3 40.1 36.6 300 CFM 33.5 39.0 39.8 36.9 375 CFM 36.7 40.1 40.5 38.6 450 CFM 41.4 44.1 43.6 42.6 Bard QW4S2 Series Q-TEC Sound Data Matrix (dBA @ 10 feet) Duct Free Supply Air Treatment Return Air Treatment Vent Option CRV Ventilation Only Part Load QPBS48 Return Grille 450 CFM 39.1 44.7 QPBS48 QRS Plenum 450 CFM 38.6 42.8 QPBS48 QRASPS Plenum 450 CFM 37.0 42.2 Duct Free Silencer QRASPS Plenum 450 CFM 36.9 41.0 Ducted Return Grille 450 CFM 34.9 40.0 Full Load Integrated dBA Sound Power Full Load Outdoor @ 10 Feet Vent Option ERV Blower Only ERV Off 39.5 300 CFM 42.0 375 CFM 45.0 45.3 42.5 59.5 41.0 450 CFM 49.6 44.2 41.3 ERV Off 38.5 300 CFM 39.8 375 CFM 40.9 450 CFM 46.1 43.1 40.2 ERV Off 37.6 300 CFM 38.1 375 CFM 38.5 450 CFM 44.0 42.1 39.4 58.0 ERV Off 37.2 300 CFM 37.9 375 CFM 38.3 450 CFM 43.2 42.5 38.6 57.2 40.0 ERV Off 36.0 300 CFM 40.0 375 CFM 43.6 450 CFM 48.0 ERV Off 34.8 Part Load 45.2 46.2 47.0 50.8 43.1 43.4 44.0 47.0 42.1 42.1 42.5 45.3 40.9 41.0 41.5 44.9 41.0 42.5 45.1 48.5 38.9 Full Load 46.0 46.8 47.5 51.1 44.2 44.4 45.0 47.5 43.0 43.2 43.2 45.8 41.6 41.7 42.0 45.1 43.1 44.1 45.7 48.8 40.8 Integrated dBA 43.1 44.4 46.1 50.2 41.4 42.0 42.7 46.6 40.3 40.6 40.8 44.7 39.3 39.7 40.1 44.0 39.5 41.6 44.4 48.3 37.6 Sound Power Full Load 65.7 61.7 64.8 Outdoor @ 10 Feet 53.8 39.6 53.8 1 Integrated values calculated per ANSI/ASA S12.60-2009/Part 2, Section 5.2.2.1, Table 2 Triple Mode Type 3 HVAC System Duty Cycles: Ventilation 58%, Part Load 25%, Full Load 17% 2 Integrated Sound Vales are also applicable for use in learning spaces for CHPS and LEED schools; EQ Prerequisite 3 - Minimum Acoustical Performance, OPTION 1. Using methods prescribed in prescribed in ANSI S12.60, classroom must achieve a maximum background noise level of 45 dBA. 3 All data recorded at rated GPM per Bard product specifications. Results Referenced Were Recorded In The Bard Manufacturing Company, Inc. Sound Lab Facility Actual Field Application Results May Vary With Classroom Design and Construction Methods 9/27/2013 Ducted Ducted QRS Plenum 450 CFM 34.4 38.1 40.8 37.2 300 CFM 36.9 39.8 41.5 38.8 375 CFM 39.6 41.1 42.5 40.6 450 CFM 45.2 45.4 45.7 45.3 ERV Off 33.0 37.4 39.1 35.9 Ducted QRASPS Plenum 450 CFM 31.3 36.4 39.0 35.1 50.8 300 CFM 34.5 37.7 39.3 36.6 375 CFM 36.1 38.5 39.6 37.5 450 CFM 42.3 42.4 42.8 42.4 57.8 Bard QW4S2 Series Q-TEC Sound Data Matrix (dBA @ 5 feet) Duct Free Supply Air Treatment Return Air Treatment Vent Option CRV Ventilation Only Part Load QPBS48 Return Grille 450 CFM 40.5 46.1 QPBS48 QRS Plenum 450 CFM 40.0 44.2 QPBS48 QRASPS Plenum 450 CFM 37.7 43.4 Duct Free Silencer QRASPS Plenum 450 CFM 37.5 42.5 Ducted Return Grille 450 CFM 37.5 42.0 Full Load Integrated dBA Sound Power Full Load Outdoor @ 10 Feet Vent Option ERV Blower Only ERV Off 40.6 300 CFM 43.8 375 CFM 48.2 47.1 44.1 450 CFM 52.0 45.8 42.8 ERV Off 39.5 300 CFM 41.3 375 CFM 42.3 450 CFM 47.1 44.0 41.2 ERV Off 38.1 300 CFM 39.4 375 CFM 39.6 450 CFM 46.4 43.4 40.6 ERV Off 38.0 300 CFM 38.9 375 CFM 39.6 450 CFM 46.4 44.4 40.8 40.0 ERV Off 37.5 300 CFM 42.9 375 CFM 47.2 450 CFM 51.1 ERV Off 35.5 Part Load 46.2 47.4 49.5 52.6 44.7 45.1 45.7 48.2 43.3 43.4 43.8 47.2 42.2 42.3 42.8 46.7 42.6 45.0 48.4 51.8 40.1 Full Load 47.2 48.4 50.1 53.1 45.4 45.9 46.9 48.8 43.6 44.5 44.4 47.3 42.8 42.6 43.4 47.1 45.1 46.4 48.6 52.0 42.5 Integrated dBA 44.2 46.0 48.9 52.4 42.7 43.5 44.4 47.7 41.1 41.9 42.0 46.8 40.4 40.7 41.4 46.6 41.2 44.3 47.8 51.4 38.8 Sound Power Full Load Outdoor @ 10 Feet 39.6 53.8 1 Integrated values calculated per ANSI/ASA S12.60-2009/Part 2, Section 5.2.2.1, Table 2 Triple Mode Type 3 HVAC System Duty Cycles: Ventilation 58%, Part Load 25%, Full Load 17% 2 Integrated Sound Vales are also applicable for use in learning spaces for CHPS and LEED schools; EQ Prerequisite 3 - Minimum Acoustical Performance, OPTION 1. Using methods prescribed in prescribed in ANSI S12.60, classroom must achieve a maximum background noise level of 45 dBA. 3 All data recorded at rated GPM per Bard product specifications. Results Referenced Were Recorded In The Bard Manufacturing Company, Inc. Sound Lab Facility Actual Field Application Results May Vary With Classroom Design and Construction Methods 9/27/2013 Ducted Ducted QRS Plenum 450 CFM 35.5 39.8 42.6 38.8 300 CFM 38.0 41.1 43.2 40.2 375 CFM 40.8 42.7 44.1 42.0 450 CFM 45.7 46.0 46.6 45.9 ERV Off 34.5 38.5 40.6 37.3 Ducted QRASPS Plenum 450 CFM 33.4 37.9 40.4 36.7 300 CFM 35.9 39.5 41.1 38.2 375 CFM 37.5 40.1 41.6 39.2 450 CFM 44.4 45.1 45.2 44.7 Form No. S3419-0521 Supersedes S3419-617 Page 21 of 26 Form No. S3419-0521 Supersedes S3419-617 Page 22 of 26 Bard QW5S2 Series Q-TEC Sound Data Matrix (dBA @ 10 feet) Duct Free Supply Air Treatment Return Air Treatment Vent Option CRV Ventilation Only Part Load QPBS48 Return Grille 450 CFM 41.6 46.5 QPBS48 QRS Plenum 450 CFM 40.1 45.8 QPBS48 QRASPS Plenum 450 CFM 38.7 45.4 Duct Free Silencer QRASPS Plenum 450 CFM 37.8 43.1 Ducted Return Grille 450 CFM 37.2 43.0 Full Load Integrated dBA Sound Power Full Load Outdoor @ 10 Feet Vent Option ERV Blower Only ERV Off 42.0 300 CFM 43.1 375 CFM 44.0 47.5 44.6 450 CFM 48.1 46.6 43.7 ERV Off 40.3 300 CFM 40.8 375 CFM 41.2 450 CFM 44.7 46.4 43.1 ERV Off 38.7 300 CFM 40.0 375 CFM 40.5 450 CFM 44.2 43.9 41.1 53.7 ERV Off 38.0 300 CFM 38.5 375 CFM 39.5 450 CFM 42.8 45.1 41.3 58.9 41.0 ERV Off 37.8 300 CFM 42.2 375 CFM 45.7 450 CFM 50.2 ERV Off 36.1 Part Load 47.2 47.4 47.9 49.9 45.1 45.0 45.6 46.8 43.8 44.1 44.4 46.4 43.4 42.9 42.8 45.0 43.9 44.9 47.2 51.6 42.7 Full Load 47.9 48.3 48.5 50.4 45.9 46.2 46.4 47.5 44.9 45.0 45.5 46.6 44.1 44.3 44.3 45.6 46.1 46.9 48.6 52.0 45.0 Integrated dBA 45.2 45.7 46.2 49.1 43.2 43.4 43.8 45.9 41.9 42.5 42.9 45.3 41.3 41.3 41.6 44.0 42.2 44.1 46.7 50.9 40.9 Sound Power Full Load 65.6 60.2 65.9 Outdoor @ 10 Feet 39.6 53.8 39.6 53.8 1 Integrated values calculated per ANSI/ASA S12.60-2009/Part 2, Section 5.2.2.1, Table 2 Triple Mode Type 3 HVAC System Duty Cycles: Ventilation 58%, Part Load 25%, Full Load 17% 2 Integrated Sound Vales are also applicable for use in learning spaces for CHPS and LEED schools; EQ Prerequisite 3 - Minimum Acoustical Performance, OPTION 1. Using methods prescribed in prescribed in ANSI S12.60, classroom must achieve a maximum background noise level of 45 dBA. 3 All data recorded at rated GPM per Bard product specifications. Results Referenced Were Recorded In The Bard Manufacturing Company, Inc. Sound Lab Facility Actual Field Application Results May Vary With Classroom Design and Construction Methods 9/27/2013 Ducted Ducted QRS Plenum 450 CFM 35.4 41.4 43.3 39.6 300 CFM 38.1 43.1 45.2 41.6 375 CFM 40.3 43.7 45.1 42.4 450 CFM 45.7 46.9 47.7 46.4 ERV Off 34.0 39.5 41.9 38.0 Ducted QRASPS Plenum 450 CFM 34.7 39.9 41.4 38.1 300 CFM 35.2 40.0 42.2 38.6 375 CFM 36.6 40.7 42.4 39.3 450 CFM 40.0 42.4 43.8 41.5 56.8 Bard QW5S2 Series Q-TEC Sound Data Matrix (dBA @ 5 feet) Duct Free Supply Air Treatment Return Air Treatment Vent Option CRV Ventilation Only Part Load QPBS48 Return Grille 450 CFM 43.0 47.8 QPBS48 QRS Plenum 450 CFM 41.2 46.5 QPBS48 QRASPS Plenum 450 CFM 39.5 46.0 Duct Free Silencer QRASPS Plenum 450 CFM 38.3 44.6 Ducted Return Grille 450 CFM 39.8 45.6 Full Load Integrated dBA Sound Power Full Load Outdoor @ 10 Feet Vent Option ERV Blower Only ERV Off 42.5 300 CFM 44.7 375 CFM 46.4 48.6 45.9 41.0 450 CFM 50.1 47.5 44.5 ERV Off 41.6 300 CFM 42.1 375 CFM 42.7 450 CFM 48.1 44.8 43.1 ERV Off 39.7 300 CFM 41.1 375 CFM 41.8 450 CFM 45.7 45.0 42.2 ERV Off 38.6 300 CFM 40.0 375 CFM 40.4 450 CFM 45.1 47.6 43.9 ERV Off 39.8 300 CFM 45.7 375 CFM 50.0 450 CFM 53.9 ERV Off 37.5 Part Load 48.6 49.1 49.5 51.6 46.2 46.4 46.6 48.7 45.9 46.2 46.1 48.3 44.8 44.4 44.9 46.7 45.3 47.8 50.6 54.2 43.8 Full Load 49.3 49.5 50.4 52.1 47.2 47.4 47.4 48.8 46.7 47.0 47.1 48.6 45.8 45.9 45.9 47.2 48.4 49.9 52.1 54.7 45.6 Integrated dBA 46.3 47.2 48.2 50.9 44.4 44.7 45.0 48.4 43.6 44.2 44.4 47.1 42.6 42.9 43.2 46.0 44.1 47.3 50.6 54.1 41.9 Sound Power Full Load Outdoor @ 10 Feet 1 Integrated values calculated per ANSI/ASA S12.60-2009/Part 2, Section 5.2.2.1, Table 2 Triple Mode Type 3 HVAC System Duty Cycles: Ventilation 58%, Part Load 25%, Full Load 17% 2 Integrated Sound Vales are also applicable for use in learning spaces for CHPS and LEED schools; EQ Prerequisite 3 - Minimum Acoustical Performance, OPTION 1. Using methods prescribed in prescribed in ANSI S12.60, classroom must achieve a maximum background noise level of 45 dBA. 3 All data recorded at rated GPM per Bard product specifications. Results Referenced Were Recorded In The Bard Manufacturing Company, Inc. Sound Lab Facility Actual Field Application Results May Vary With Classroom Design and Construction Methods 9/27/2013 Ducted Ducted QRS Plenum 450 CFM 36.5 42.7 44.4 40.8 300 CFM 39.6 44.5 45.9 42.8 375 CFM 41.8 45.1 46.6 43.9 450 CFM 45.9 48.3 49.0 47.2 ERV Off 34.9 40.7 43.4 39.3 Ducted QRASPS Plenum 450 CFM 35.8 41.3 42.6 39.4 300 CFM 36.2 41.5 43.6 39.9 375 CFM 37.8 41.8 43.8 40.6 450 CFM 41.9 43.8 44.9 43.1 Optional Accessories Must be Used for Each Installation with Ventilation Options Ventilation Wall Sleeves: QWVS42 Ventilation wall sleeve for walls up to 14 inches thick. NOTE: Unless they are to be field-supplied, side trim kit must be ordered for all installations. Ventilation Louvers: QLW-10 Standard Clear Painted Enamel Finish for vent option QLW-20 Standard Medium Bronze Painted Enamel Finish for vent option QLW-30 Standard Dark Bronze Painted Enamel Finish for vent option QLW-* Optional Louver Finishes available (See Form S3508) Contact your Bard Sales Representative for Custom Finish Louver information Side Trim Kits -- Required for All Installations Unless Field-Supplied NOTE: The following accessory items must be selected so the finish (color) is matched to the QWS model that they will be used with. Side Trim Extension Kits: Unit Compatibility Model Color Model Color Model Color Model Color Space from back of unit to wall QSTX-V-6 Platinum Vinyl QSTX-4-6 Gray Paint QSTX-X-6 Beige Paint QSTX-1-6 White Paint 4" to 6" All QSTX-V-8 Platinum Vinyl QSTX-4-8 Gray Paint QSTX-X-8 Beige Paint QSTX-1-8 White Paint 6" to 8" All QSTX-V-10 Platinum Vinyl QSTX-4-10 Gray Paint QSTX-X-10 Beige Paint QSTX-1-10 White Paint 8" to 10" All QSTX-V-12 Platinum Vinyl QSTX-4-12 Gray Paint QSTX-X-12 Beige Paint QSTX-1-12 White Paint 10" to 12" All Optional Accessories -- Additional Items as Determined by Job Specifications Duct-Free Plenum Boxes: Unit Compatibility QPB42-V QPBS42-V QPBS42-V-8 QPB48-V QPBS48-V QPBS48-V-8 Platinum Vinyl QPB42-4 Platinum Vinyl QPBS42-4 Platinum Vinyl QPBS42-4-8 Platinum Vinyl QPBS48-4 Platinum Vinyl QPBS48-4 Platinum Vinyl QPBS48-4-8 Gray Paint QPB42-X Gray Paint QPBS42-X Gray Paint QPBS42-X-8 Gray Paint QPBS48-X Gray Paint QPBS48-X Gray Paint QPBS48-X-8 Beige Paint QPB42-1 Beige Paint QPBS42-1 Beige Paint QPBS42-1-8 Beige Paint QPBS48-1 Beige Paint QPBS48-1 Beige Paint QPBS48-1-8 White Paint Front supply, 4-way deflection grille White Paint Same as QPB42, plus 2-way deflection grille on each side White Paint Same as QPBS42 and 8" Height j White Paint Front supply, 4-way deflection grille White Paint Same as QPB48, plus 2-way deflection grille on each side White Paint Same as QPBS48 and 8" Height j QW2S, QW3S QW2S, QW3S QW2S, QW3S QW4S, QW5S QW4S, QW5S QW4S, QW5S Top Fill Systems for Finishing Plenum Boxes to Ceilings: Unit Compatibility QPBX42-9-V QPBX42-10-V QPBX48-9-V QPBX48-10-V Platinum Vinyl QPBX42-9-4 Gray Paint QPBX42-9-X Platinum Vinyl QPBX42-10-4 Gray Paint QPBX42-10-X Platinum Vinyl QPBX48-9-4 Gray Paint QPBX48-9-X Platinum Vinyl QPBX48-10-4 Gray Paint QPBX48-10-X Beige Paint QPBX42-9-1 Beige Paint QPBX42-10-1 Beige Paint QPBX48-9-1 Beige Paint QPBX48-10-1 White Paint Use with QPB42 or QPBS42 (adjusts to ceilings up to 9'9") White Paint Use with QPB42 or QPBS42 (adjusts to ceilings up to 10'5") White Paint Use with QPB48 or QPBS48 (adjusts to ceilings up to 9'9") White Paint Use with QPB48 or QPBS48 (adjusts to ceilings up to 10'5") QW2S, QW3S QW4S, QW5S Cabinet Extensions for Ducted Applications: Unit Compatibility QCX10A-V QCX15A-V Platinum Vinyl QCX10A-4 Platinum Vinyl QCX15A-4 Gray Paint QCX10A-X Gray Paint QCX15A-X Beige Paint QCX10A-1 Beige Paint QCX15A-1 White Paint 20" height (adjusts for ceilings up to 9'7"; add QPBX42-9 for 9'7" to 10'3" finished ceiling heights) White Paint 20" height (adjusts for ceilings up to 9'7"; add QPBX48-9 for 9'7" to 10'3" finished ceiling heights) QW2S, QW3S QW4S, QW5S Hot Water Coils with Plenum Boxes: Unit Compatibility QPBHW42-F-V QPBHW48-F-V QPBHW42-D-V QPBHW48-D-V Platinum Vinyl QPBHW42-F-4 Gray Paint Platinum Vinyl QPBHW48-F-4 Gray Paint Platinum Vinyl QPBHW42-D-4 Gray Paint Platinum Vinyl QPBHW48-D-4 Gray Paint QPBHW42-F-X QPBHW48-F-X QPBHW42-D-X QPBHW48-D-X Beige Paint QPBHW42-F-1 Beige Paint QPBHW48-F-1 Beige Paint QPBHW42-D-1 Beige Paint QPBHW48-D-1 White Paint White Paint White Paint White Paint Free blow plenum box Free blow plenum box Ducted plenum box Ducted plenum box QW2S, QW3S QW4S, QW5S QW2S, QW3S QW4S, QW5S NOTE: The same top fill system and cabinet extensions can be used with hot water coil plenum boxes as with standard plenum boxes. j 8" Plenum Box height may affect sound level of supply air and unit. Form No. S3419-0521 Supersedes S3419-617 Page 23 of 26 WATER CONNECTION OPTIONS Female National Pipe Thread (NPT) Connections (Piping Option "P") 1" Female National Pipe Thread (NPT) copper fitting connections at inlet and outlet of co-axial water coil. No internal pump options available with piping option "P". Double O-Ring Water Connections (Piping Option "X") IMPORTANT NOTE: Water coils can be equipped with male half of double O-ring fittings and a mating half must be used. No other type of fitting will mate up. The DORFC Flow Centers also have double O-ring connections on both heat pump and loop sides of flow center. Depending upon pump and piping options ordered, additional double O-ring fittings and hose may be required. Fittings are available for threaded, barbed, soldered and fusion connections. Elbow, 1" MPT X Double O-ring with 1/4" Port and Pressure/ Temperature Test Plugs DORMP1-90 Elbow, 1" MPT X Double O-ring with 1/4" Port and 1/4" Brass Pipe Plugs DORMP1-90P 1" MPT X Double O-ring DORMP1-S 1" FPT X Double O-ring DORFP1-S Elbow, 1" Hose Barb X Double O-ring with 1/4" Port and Pressure/ Temperature Test Plugs DORB1-90-4HC Elbow, 1" Hose Barb X Double O-ring with 1/4" Port and 1/4" Brass Pipe Plugs DORB1-90P-4HC 1" Hose Barb X Double O-ring DORB1-S-4HC 1-1/4" Socket Fusion X Double O-ring DORF125-S 1" Copper Sweat X Double O-ring with 1/4" FPT Port & Pressure/Temperature Test Plugs DORS1-S Individual Double O-Ring Fitting Packs (Qty 2 per pack) DORMP1-90 (2) 1" MPT 90° double o-ring elbows with 1/4" FPT ports and 8603-026 pressure/temperature test plugs DORMP1-90P (2) 1" MPT 90° double o-ring elbows with 1/4" FPT ports and 1/4" brass pipe plugs DORMP1-S (2) 1" MPT straight double o-ring fittings DORFP1-S (2) 1" FPT straight double o-ring fittings DORB1-90-4HC (2) 1" barbed 90° double o-ring elbows with 1/4" FPT ports, 8603-026 pressure/temperature test plugs and (4) SS 1" hose clamps DORB1-90P-4HC (2) 1" barbed 90° double o-ring elbows with 1/4" FPT ports, 1/4" brass pipe plugs and (4) SS 1" hose clamps DORB1-S-4HC (2) 1" barbed straight double o-ring fittings with (4) 1" SS hose clamps DORF125-S (2) 1.25" fusion straight double o-ring fittings DORS1-S (2) 1" copper sweat straight double o-ring fittings with 1/4" FPT ports and 8603-026 pressure/temperature test plugs Optional Hose Form No. S3419-0521 Supersedes S3419-617 Page 24 of 26 HK1-25 (1) 25' section of 1" ID 150 PSI hose Flow Centers & Individual Pumps w/Double O-Ring Connections (See Pump Ratings Below) Pump Option 1 2 3 4 5 Pump Model DORFC-1 DORFC-2 UPS15-42F UP26-64F UPS26-99FC No. of Pumps Description 1 Loop Flow Center w/Insulated Cabinet, 230V-60Hz-1Ph, Double O-ring Fittings, UP26-99F Pump, Brass Isolation & Flush Valves Built-In 2 Loop Flow Center w/Insulated Cabinet, 230V-60Hz-1Ph, Double O-ring Fittings, UP26-99F Pump, Brass Isolation & Flush Valves Built-In 1 Pump with Isolation Valves, 230V-60Hz-1Ph, Piped to Rear of Cabinet, Double O-ring Connections 1 Pump with Isolation Valves, 230V-60Hz-1Ph, Piped to Rear of Cabinet, Double O-ring Connections 1 Pump with Isolation Valves, 230V-60Hz-1Ph, Piped to Rear of Cabinet, Double O-ring Connections Installation Method Can be factory or field installed Factory installed only DORFC-2 UPS26 Flow Center and Individual Pump Accessories Bard Part Number Required Quantity Description Used With QWRK Consists of control relay, two 3A circuit breakers, all wiring and all Included with factory installed DORFC Flow 1 installation parts Centers and UPS Pumps. Order only if field installing any flow center or pump. QWHK Consists of two 1" x 33" 200 PSIG hoses with SS braided sheathing Included with units for factory installed 1 and fitted with straight double o-ring fittings one end and 90° elbow DORFC's. Order only if field installing DORFC. double o-ring fittings with P/T ports installed on opposite end. j This is factory installed if flow center or pump is factory installed. Loop Pump Modules and Individual Pump Capacities jk For Use with Pump QWS Models l Option Pump Model No. of Pumps No. of Speeds Speed 5 6 7 8 WATER FLOW in GPM 9 10 11 12 13 14 15 16 ALL 1 DORFC-1 1 1 Single 29.5 29 28.5 28 27.5 26.5 25.5 24.5 23 22.5 22 21 ALL 2 DORFC-2 2 1 Single 59 58 57 56 55 53 51 49 46 45 44 42 QW2 - 3S 3 UPS15-42F 1 High 12.1 11.5 10.7 9.7 8.8 8 ------------ 3 Medium 6.8 5.7 4.5 -- -- -- -- -- -- -- -- -- Low -- -- -- -- -- -- -- -- -- -- -- -- QW2 - 3S 4 UP26-64F 1 1 Single 21.5 21 20 19 18 17 16.5 16 15 14 13 12.5 QW3 - 5S 5 UPS26-99FC 1 High 29.5 29 28.5 28 27.5 26.5 25.5 24.5 23 22.5 22 21 3 Medium 23.5 22.2 21.5 20.3 19.5 18.5 17.8 16.5 15.3 14.3 13.3 12.4 Low 15.3 13.8 12.4 10.9 9.8 8.4 -- -- -- -- -- -- j Pump output shown in feet head @ GPM at top of columns. k Refer to Water Coil Pressure Drop table (Page 8) for feet head allowances for basic QW*S complete system. Additional feet head allowance from basic unit to main piping loop must be included and determined by others. l Pump options shown can be factory installed in models as shown. Suitability of each must be determined by others based on QWS requirements, plus the loop design requirements designed by others. Ground Loop Service Accessories for Installations with DORFC Flow Centers Heat Pump Model Bard Part Number DORCL1-90 CLB1-S GGK-1 DORGHMT Required Quantity Each Each Each Each Description (2) 90° double o-ring quick-connect cam-lever male fittings for flush attachment to loop flow center (2) 1" straight barbed quick-connect cam-lever female fittings to connect to DORCL1-90 fittings above (1) Geo-Gooser w/shut-off valve, 0-100 PSI gauge, garden hose connection, P/T fitting 1/8' probe (2) Double o-ring x male garden hose adapter fitting for loop flow center (to burp/boost loop) 1" Cam Lever Male X Double O-ring DORCL1-90 CLB1-S Garden Hose Male X O-ring (single) Adapter DORGHMT GGK-1 Form No. S3419-0521 Supersedes S3419-617 Page 25 of 26 QW*S Step Capacity Series Q-TEC Geothermal HP Model Nomenclature QW 3 S 2 A 0Z B X VX C X MODEL NUMBER | Q-TEC Model KW 0Z - OKW FILTER OPTIONS X - 2-Inch Pleated COIL OPTIONS C - Copper water CAPACITY | (MERV8) N - Cupronickel 2 - 2 Ton 3 - 3 Ton 4 - 4 Ton 5 - 5 Ton STEP CAPACITY | REVISION | VOLTS & PHASE A - 230/208/60/1 B - 230/208/60/3 C - 460/60/3 COLOR 1 - White paint 4 - Buckeye Gray paint X - Beige paint NOTE: Copper Coils approved for Ground Loop and Closed Loop Boiler/Tower only. V - Platinum w/Slate SPECIALTY Front (Vinyl) PRODUCTS j (Non-Standard) | CLIMATE CONTROL OPTIONS (Factory Mounted) X = 24V Terminal Block Only k D = 8403-060 Electronic/Programmable Thermostat w/Humidity Control VENTILATION OPTIONS B - Blank-off Plate V - Commercial Ventilator - Motorized w/Exhaust Spring Return R - Energy Recovery Ventilator w/Independent Intake & Exhaust Control S - Energy Recovery Ventilator w/Intelligent Frost Control Option T - Energy Recovery Ventilator w/Occupied Space CFM Control Option H = 8403-060 Prog. Thermostat w/Humidity Control + 8403-067 CO2 Controller K = 24V Terminal Block + 8403-067 CO2 Controller Only 1 = CompleteStat CS9B-THO (Temp, Humidity & Occupancy) l 2 = CompleteStat CS9B-THOC (THO + CO2) l 3 = CompleteStat CS9BE-THO (THO w/Ethernet) m 4 = CompleteStat CS9BE-THOC (THO + CO2 w/Ethernet) m 5 = 8403-069 Viconics VT7652H5000B w/BACnet 6 = 8403-069 Viconics + 8403-067 CO2 Controller 7 = 8403-071 Viconics VT7600H5500B Non-Prog w/BACnet & PIR cover 8 = 8403-075 Viconics VT7600H5000B Non-Prog w/BACnet + 8403-067 CO2 Controller NOTE: j Insert "D" for dehumidification with hot gas reheat. Reference 7960-658 for complete details. k If "X" control option is selected, then thermostat and humidistat, if applicable, or DDC control system must be field supplied. l CS9B-THO and -THOC are BACnet w/shielded twisted pair wiring. m CS9BE-THO and -THOC are BACnet w/shielded twisted pair wiring and Ethernet port. Not available for Dehumidification Models. FACTORY INSTALLED PUMP & PIPING OPTIONS X - None; all pump & water connections field installed, requires field piping to the coaxial water coil using double o-ring fittings, which must be ordered separately. P - None; all pump & water connections field installed, requires field piping to the coaxial water coil 1" Female NPT wrought copper fittings. 1 - DORFC-1 double o-ring flow center, single Grundfos UP26-99F pump piped to water coil with 150 PSI reinforced hose 2 - DORFC-2 double o-ring flow center, double Grundfos UP26-99F pump piped to water coil with 150 PSI reinforced hose 3 - Single Grundfos UPS15-42F pump, isolation valves both ends, piped with copper to double o-ring fittings back corners of unit 4 - Single Grundfos UP26-64F pump, isolation valves both ends, piped with copper to double o-ring fittings back corners of unit 5 - Single Grundfos UPS26-99-FC pump, isolation valves both ends, piped with copper to double o-ring fittings back corners of unit See Pages 23, 24 & 25 for Additional Required and Optional Field Installed Accessories Optional Field Installed Hard Start Kits for 1-Phase Models j Unit Model Field Installed Part Number QW2S2-A only SK111 QW3S2-A only SK111 QW4S2-A only SK118 QW5S2-A only SK118 j Start Capacitor and potential relay start kit can be used with all -A single phase models only. Increases starting torque 9x. Not used on -B or -C three phase models. Optional Field Installed Evap. Drain Pan Overflow Kit Part Number Description 8620-219 24VAC 0.4A SPST NC Switch to shutdown compressor. Can be converted to NO action to use for alarm circuit. Bard Manufacturing Company, Inc. Bryan, Ohio 43506 www.bardhvac.com Form No. S3419-0521 Supersedes S3419-617 Page 26 of 26 Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Form No. S3419 May 2021 Supersedes: S3419-617