Fluke 62 MAX / 62 MAX + Infrared Thermometer

Users Manual

Introduction

The Fluke 62 MAX and 62 MAX + Infrared Thermometers (the Product) can determine the surface temperature by measuring the amount of infrared energy radiated by the target's surface. Note that the Japanese models indicate Celsius only.

[Warning] Read all safety information before you use the Product.

How to Contact Fluke

To contact Fluke, call one of the following telephone numbers:

Or, visit Fluke's website at www.fluke.com.

To register your product, visit http://register.fluke.com.

To see, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals.

Safety Information

A [Warning] identifies conditions and procedures that are dangerous to the user. A [Caution] identifies conditions and procedures that can cause damage to the Product or the equipment under test.

Table 1 describes symbols used on the Product and in this manual.

[Warning] To prevent eye damage and personal injury:

Table 1. Symbols

Symbol Meaning Symbol Meaning
[Warning symbol] Risk of danger. Important information. See Manual. [WEEE symbol] This product complies with the WEEE Directive (2002/96/EC) marking requirements. The affixed label indicates that you must not discard this electrical/electronic product in domestic household waste. Product Category: With reference to the equipment types in the WEEE Directive Annex I, this product is classed as category 9 "Monitoring and Control Instrumentation" product. Do not dispose of this product as unsorted municipal waste. Go to Fluke's website for recycling information.
[Laser Warning symbol] Warning. Laser. CE Conforms to European Union directives.
[Battery symbol] Battery [Australian standards symbol] Conforms to relevant Australian standards.
[China Metrology Certification symbol] Conforms to China Metrology Certification

Maintenance

[Caution] To avoid damage to the Product, do not leave the thermometer on or near objects of high temperature.

How to Change the Battery

To install or change the AA IEC LR06 battery, open the battery compartment and replace the battery as shown in Figure 16.

How to Clean the Product

Use soap and water on a damp sponge or soft cloth to clean the Product case. Carefully wipe the surface with a moist cotton swab. The swab may be moistened with water. See Figure 17.

Specifications

62 MAX 62 MAX +
Temperature Range -30 °C to 500 °C (-22 °F to 932 °F) -30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy (Calibration geometry with ambient temperature 23 °C ±2 °C) ≥0 °C: ±1.5 °C or ±1.5% of reading, whichever is greater
(≥32 °F: ±3 °F or ±1.5% of reading, whichever is greater)
> -10 °C to <0 °C: ±2 °C (≥14 °F to <32 °F: ±4 °F)
< -10 °C: ±3 °C (<14 °F: ±6 °F)
≥0 °C: ±1 °C or ±1% of reading, whichever is greater (≥32 °F: ±2 °F or ±1% of reading, whichever is greater)
> -10 °C to <0 °C: ±2 °C (≥14 °F to <32 °F: ±4 °F)
< -10 °C: ±3 °C (<14 °F: ±6 °F)
Response Time (95 %) <500 ms (95 % of reading) <300 ms (95 % of reading)
Spectral Response 8 to 14 microns 8 to 14 microns
Emissivity 0.10 to 1.00 0.10 to 1.00
Temperature Coefficient ±0.1 °C/°C or ±0.1%/°C of reading (whichever is greater) ±0.1 °C/°C or ±0.1%/°C of reading (whichever is greater)
Optical Resolution 10:1 (calculated at 90 % energy) 12:1 (calculated at 90 % energy)
Display Resolution 0.1 °C (0.2 °F) 0.1 °C (0.2 °F)
Repeatability (% of reading) ±0.8 % of reading or ±1.0 °C (2 °F), whichever is greater ±0.5 % of reading or ±0.5 °C (1 °F), whichever is greater
Power 1 AA IEC LR06 Battery 1 AA IEC LR06 Battery
Battery Life 10 hours with laser and backlight on 8 hours with laser and backlight on
Weight 255 g (8.99 oz) 255 g (8.99 oz)
Size (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating Temperature 0 °C to 50 °C (32 °F to 122 °F) 0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature -20 °C to 60 °C (-4 °F to 140 °F), (without battery) -20 °C to 60 °C (-4 °F to 140 °F), (without battery)
Operating Humidity 10 % to 90 % RH non-condensing @ 30 °C (86 °F) 10 % to 90 % RH non-condensing @ 30 °C (86 °F)
Operating Altitude 2000 meters above mean sea level 2000 meters above mean sea level
Storage Altitude 12,000 meters above mean sea level 12,000 meters above mean sea level

Standards and Agency Approval

Ingress Protection Rating IP 54 per IEC 60529
Drop Test 3 meters
Vibration and Shock IEC 60068-2-6 2.5 g, 10 to 200 Hz, IEC 60068-2-27, 50 g, 11 ms
EMC EN 61326-1:2006 EN 61326-2:2006

Compliance Details

The Product

Diagram 1: Product Overview

Shows the Fluke 62 MAX/MAX+ infrared thermometer with a laser warning label. The label indicates 'LASER RADIATION DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT λ=650nm,<1mW,EN60825-1:2007'. Two views of the device are presented.

Diagram 2: Device Display

Illustrates the device's LCD display in 'SCAN' mode. It shows temperature units (°C/°F), a large temperature reading (e.g., 1888.8), and indicators for Max, Alarm, HILO, EMS, Min, Avg, and Diff. An example reading of '1880' is also shown.

Diagram 3: Laser Operation

Demonstrates how to turn the laser pointer on and off using the 'SET' button. The display shows 'LAS ON' and 'LAS OFF'.

Diagram 4: Temperature Units

Shows how to switch between Fahrenheit (°F) and Celsius (°C) temperature units using the 'SET' button.

Diagram 5: Emissivity Adjustment

Illustrates adjusting the Emissivity (EMS) setting. The display shows example EMS values like '0.98' and '0.58', with a current reading of '0.88'.

Diagram 6: Measurement Modes

Explains how to access and view Maximum (Max), Minimum (Min), Average (Avg), and Differential (Diff) temperature readings using the 'SEL' button. Example readings are shown: Max 68.0, Min 68, Avg 76, Diff 22.

Diagram 7: Auto-Off Timer

Depicts setting the auto-off timer. Options shown include 'tr19 On' and '10 min', and the ability to turn it 'OFF'.

Diagram 8: Alarm Settings

Shows how to set High (HI) and Low (LO) alarms. Example setpoints displayed are 'Alarm HI 357', 'Alarm HI 358', 'Alarm LO 20', 'Alarm LO 19', and 'OFF'.

Diagram 9: Alarm Indication

Illustrates how the device indicates when a set alarm threshold is met. It displays the alarm type (HI/LO) and the measured temperature, e.g., 'Alarm HI 357', 'Alarm HI 356', 'Alarm LO 20', 'Alarm LO 19'.

Diagram 10: Pipe Temperature Measurement

Shows measuring the temperature of a pipe. It indicates a 30-minute timer and displays ambient temperatures (0°C/32°F) and target temperatures (22°C/72°F).

Diagram 11: Safety Warnings

Displays warnings related to laser safety and operating near high temperatures (125°F). It shows a laser beam pointing at a person's eye with a warning symbol.

Diagram 12: 62 MAX Distance-to-Spot Ratio

Illustrates the Distance-to-Spot (D:S) ratio for the 62 MAX model (10:1). It shows how the measurement spot size increases with distance: 1.5" spot at 12" distance, 2.4" spot at 24" distance, and 4" spot at 36" distance. The laser beam spread is also depicted.

Diagram 13: 62 MAX+ Distance-to-Spot Ratio

Illustrates the Distance-to-Spot (D:S) ratio for the 62 MAX+ model (12:1). It shows how the measurement spot size increases with distance: 1.4" spot at 12" distance, 2" spot at 24" distance, and 3.4" spot at 36" distance. The laser beam spread is also depicted.

Diagram 14: Scanning and Readings

Demonstrates scanning a surface and displaying various readings like Max, Min, Avg, and Diff. It shows how to use the 'SEL' button to cycle through these modes. Example readings shown include Max 90.0, Min 70, Avg 76, Diff 22.

Diagram 15: Measuring Through Obstacles

Shows measuring the temperature of a pipe through a wall. It indicates measurements at different angles (75°, 225°, 75°) and displays readings like 125.2°F (Max) and 225.0°F (Max), with an 'OK' confirmation and a reading of 236.

Diagram 16: Battery Replacement

Shows the process of replacing the AA IEC LR06 battery in the device, indicating the positive (+) and negative (-) terminals.

Diagram 17: Cleaning Instructions

Illustrates cleaning the device with a damp cotton swab and cloth. A symbol indicates not to use a bucket of water.

Limited Warranty and Limitation of Liability

This Fluke product will be free from defects in material and workmanship for three years from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke's behalf. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem.

THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you.

Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.

Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands

(Document Revision: 11/99)

Models: Infrared Thermometer, 62 MAX, 62 MAX

File Info : application/pdf, 22 Pages, 1.32MB

PDF preview unavailable. Download the PDF instead.

A13L0grAqLS

References

Acrobat Distiller 10.1.3 (Windows)

Related Documents

Preview Fluke 64 MAX, 62 MAX+, 62 MAX IR Thermometers: Technical Data & Specifications
Explore the technical specifications and key features of the Fluke 64 MAX, 62 MAX+, and 62 MAX infrared thermometers. Discover their robust design, precise measurements, and suitability for demanding environments.
Preview Fluke 56x Infrared Thermometers User Manual
Comprehensive user manual for Fluke 561, 566, and 568 Infrared Thermometers, covering features, operation, maintenance, troubleshooting, and specifications. Includes safety information and accessory details.
Preview Fluke 568 EX Infrared Thermometer User Manual
User manual for the Fluke 568 EX Infrared Thermometer, detailing its features, operation in potentially explosive areas, safety guidelines, troubleshooting, and specifications. Includes ATEX compliance information.
Preview Fluke 67 MAX Clinical Infrared Thermometer Product Announcement
Announcing the Fluke 67 MAX Clinical Infrared Thermometer, a non-contact device for accurate human temperature measurement, featuring Body Mode, SCAN functionality, and rugged design. Includes specifications, included items, and pricing.
Preview Fluke 62 MAX IR Thermometer - Product Specifications and Information
Detailed specifications and description for the Fluke 62 MAX IP54 IR Thermometer, including features, manufacturer information, and packaging details. This infrared thermometer is designed for accurate temperature measurement in demanding environments.
Preview Fluke 59 MAX/59 MAX+ Infrared Thermometer: User Manual & Specifications
This user manual provides detailed information on the Fluke 59 MAX and 59 MAX+ infrared thermometers, including operation, safety guidelines, specifications, and maintenance. Learn how to accurately measure surface temperatures with these advanced devices.
Preview Fluke 561 HVAC Infrared & Contact Thermometer: Features, Specifications, and Ordering
Explore the Fluke 561, a versatile infrared and contact thermometer designed for HVAC/R professionals. This document details its key features, technical specifications, and available ordering options for efficient temperature measurement.
Preview Fluke 'Buy the Best and Get Even More' Accessory Promotion
Details the Fluke 'Buy the Best and Get Even More' promotion, offering a free accessory with the purchase of select Fluke products between October 1 and December 26, 2008. Lists eligible products, available accessories, redemption steps, terms, and conditions.