User Manual for MEAN WELL models including: ELG-100 Series 70 100W Constant Voltage Plus Constant Current LED Driver, ELG-100 Series, 70 100W Constant Voltage Plus Constant Current LED Driver, Constant Voltage Plus Constant Current LED Driver, Voltage Plus Constant Current LED Driver, Constant Current LED Driver, Current LED Driver, LED Driver, Driver
11 ott 2024 — All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature. 2. Please refer to "DRIVING METHODS OF ...
AC/L(Brown) AC/N(Blue) DIMMING OPERATION ELG-100 Applying additive 0 ~ 10VDC Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz):
File Info : application/pdf, 11 Pages, 1.55MB
DocumentDocumentE L G - 1 0 0 70~100W Constant Voltage + Constant Current LED Driver series User's Manual IP65 IP67 IS 15885(Part 2/Sec13) THOMAS SAMUEL THOMAS SAMUEL R-41027766 (Please refer safety description) { A Dx File Name:ELG-100-SPEC 2024-01-08 E L G - 1 0 0 70~100W Constant Voltage + Constant Current LED Driver series SPECIFICATION MODEL ELG-100-24 ELG-100-36 ELG-100-42 ELG-100-48 DC VOLTAGE 24V CONSTANT CURRENT REGION Note.2 12 ~ 24V RATED CURRENT 4.0A 36V 18 ~ 36V 2.66A 42V 21 ~ 42V 2.28A 48V 24 ~ 48V 2A 200VAC ~ 305VAC RATED POWER 96W 95.76W 95.76W 96W 100VAC ~ 180VAC 70W 70W 70W 70W RIPPLE & NOISE (max.) Note.3 200mVp-p 250mVp-p 250mVp-p 300mVp-p OUTPUT VOLTAGE ADJ. RANGE Adjustable for A/AB-Type only (via the built-in potentiometer) 21.6 ~ 26.4V 32.4 ~ 39.6V 37.8 ~ 46.2V 43.2 ~ 52.8V CURRENT ADJ. RANGE Adjustable for A/AB-Type only (via the built-in potentiometer) 2 ~ 4A 1.33 ~ 2.66A 1.14 ~ 2.28A 1 ~ 2A VOLTAGE TOLERANCE Note.4 ±3.0% ±2.5% ±2.5% ±2.0% LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% LOAD REGULATION ±1.0% ±1.0% ±0.5% ±0.5% SETUP, RISE TIME Note.6 1000ms, 80ms/115VAC 500ms, 100ms/230VAC HOLD UP TIME (Typ.) 15ms/115VAC 10ms/230VAC VOLTAGE RANGE Note.5 100 ~ 305VAC 142 ~ 431VDC continue,320VAC for 24Hrs; 360VAC for 1Hr (Please refer to "STATIC CHARACTERISTIC" section) FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR PF0.97/115VAC, PF0.95/230VAC, PF0.92/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section) ELG-100-54 54V 27 ~ 54V 1.78A 96.12W 70W 350mVp-p 48.6 ~ 59.4V 0.89 ~ 1.78A ±2.0% ±0.5% ±0.5% TOTAL HARMONIC DISTORTION THD< 20%(@load50%/115VC; @load60%/230VAC; @load75%/277VAC) (Please refer to "TOTAL HARMONIC DISTORTION(THD)" section) INPUT EFFICIENCY (Typ.) 88% 89% 90% 90% 91% AC CURRENT INRUSH CURRENT(Typ.) 1.1A / 115VAC 0.6A / 230VAC 0.5A/277VAC COLD START 60A(twidth=850s measured at 50% Ipeak) at 230VAC; Per NEMA 410 MAX. No. of PSUs on 16A CIRCUIT BREAKER 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC LEAKAGE CURRENT <0.75mA / 277VAC NO LOAD / STANDBY POWER CONSUMPTION No load power consumption <0.5W for Blank / A / Dx / D2-Type Standby power consumption <0.5W for B / AB / DA-Type OVER CURRENT 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed SHORT CIRCUIT PROTECTION OVER VOLTAGE Hiccup mode, recovers automatically after fault condition is removed 28 ~ 34V 41 ~ 48V 47 ~ 54V Shut down output voltage, re-power on to recover 54 ~ 62V 62 ~ 72V OVER TEMPERATURE WORKING TEMP. MAX. CASE TEMP. ENVIRONMENT WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT Shut down output voltage, re-power on to recover Tcase=-40 ~ +90 (Please refer to " OUTPUT LOAD vs TEMPERATURE" section) Tcase=+90 20 ~ 95% RH non-condensing -40 ~ +80, 10 ~ 95% RH ±0.03%/ (0 ~ 60) VIBRATION SAFETY STANDARDS 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes UL8750(type"HL"), CSA C22.2 No. 250.13-12; IEC/BS EN/EN/AS/NZS 61347-1, IEC/BS EN/EN/AS/NZS 61347-2-13 independent, BS EN/EN62384; EAC TP TC 004;BIS IS15885(for 24/24A/24B/24DA/36/36A/36B/42/42A/42ADA/42B/48/48B/54/54A/54ADA/54B only); GB19510.1, GB19510.14; IP65 or IP67;KC61347-1,KC61347-2-13 approved SAFETY & EMC DALI STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION Compliance to IEC62386-101,102,(207 by request) for DA Type only I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55015,BS EN/EN61000-3-2 Class C (@load60%); BS EN/EN61000-3-3;GB/T 17743, GB17625.1; EAC TP TC 020; KC KN15,KN61547 EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV); EAC TP TC 020; KC KN15,KN61547 MTBF OTHERS DIMENSION 2920.8K hrs min. Telcordia SR-332 (Bellcore) 199*63*35.5mm (L*W*H) 282.9Khrs min. MIL-HDBK-217F (25) PACKING 0.85kg; 16pcs/14.2kg/0.72CUFT NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 of ambient temperature. 2. Please refer to "DRIVING METHODS OF LED MODULE". For DA-Type, Constant Current region is 60%~100% of maximum voltage under rated power delivery. 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 4. Tolerance : includes set up tolerance, line regulation and load regulation. 5. De-rating may be needed under low input voltages. Please refer to "STATIC CHARACTERISTIC" sections for details. 6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time. 7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) 8. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 80 or less. 9. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com 10. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). 11. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf 12. D2 models need to be programmed in the state of loading. 13.To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains. Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:ELG-100-SPEC 2024-01-08 E L G - 1 0 0 70~100W Constant Voltage + Constant Current LED Driver series Block Diagram PFC fosc : 50~120KHz PWM fosc : 60~130KHz EMI FILTER I/P & RECTIFIERS PFC CIRCUIT POWER RECTIFIERS Vo+ SWITCHING & FILTER Vo- O.L.P. O.T.P. O.L.P. PWM & PFC CONTROL DETECTION CIRCUIT O.V.P. CASE :Protective Earth DRIVING METHODS OF LED MODULE This series is able to work in either Constant Current mode (a direct drive way) or Constant Voltage mode (usually through additional DC/DC driver) to drive the LEDs. 100 Vo(%) 50 (min.) (A) Constant Voltage area (B) Constant Current area (C) Hiccup Protection 50 100 Io(%) Typical output current normalized by rated current (%) In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. Should there be any compatibility issues, please contact MEAN WELL. This characteristic applies to Blank/A/B/AB/DX/D2-Type, For DA-Type, the Constant Current area is 60%~100% Vo. File Name:ELG-100-SPEC 2024-01-08 E L G - 1 0 0 70~100W Constant Voltage + Constant Current LED Driver series DIMMING OPERATION AC/N(Blue) AC/L(Brown) ELG-100 DIM+(Purple)* DIM-(Pink)** Vo-(Black) Vo+(Red) 3 in 1 dimming function (for B/AB-Type) Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: 0 ~ 10VDC, or 10V PWM signal or resistance. Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers. Dimming source current from power supply: 100A (typ.) * DIM+ for B/AB-Type DA+ for DA-Type PROG+ for D2-Type * *DIM- for B/AB-Type DA- for DA-Type PROG- for D2-Type Applying additive 0 ~ 10VDC 100% 90% Vo+ + 80% + 70% Output current (%) Vo- 60% - 50% DIM+ + 40% Additive Voltage 30% - 20% DIM- 10% "DO NOT connect "DIM- to Vo-" 0% 0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V Dimming input: Additive voltage Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz): Vo+ + + Vo- - DIM+ Additive PWM signal DIM- "DO NOT connect "DIM- to Vo-" Output current (%) 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Duty cycle of additive 10V PWM signal dimming input Applying additive resistance: 100% Output current (%) Vo+ + VoDIM+ 90% + 80% 70% - 60% 50% 40% Additive Resistance 30% DIM- 20% "DO NOT connect "DIM- to Vo-" 10% 0% Short 10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N (N=driver quantity for synchronized dimming operation) Dimming input: Additive resistance Note : 1. Min. dimming level is about 8% and the output current is not defined when 0%< Iout<8%. 2. The output current could drop down to 0% when dimming input is about 0k or 0Vdc, or 10V PWM signal with 0% duty cycle. File Name:ELG-100-SPEC 2024-01-08 E L G - 1 0 0 70~100W Constant Voltage + Constant Current LED Driver series DALI Interface (primary side; for DA-Type) Apply DALI signal between DA+ and DA-. DALI protocol comprises 16 groups and 64 addresses. First step is fixed at 8% of output. Smart timer dimming function (for Dxx-Type by User definition) MEAN WELL Smart timer dimming primarily provides the adaptive proportion dimming profile for the output constant current level to perform up to 14 consecutive hours. 3 dimming profiles hereunder are defined accounting for the most frequently seen applications. If other options may be needed, please contact MEAN WELL for details. Ex : D01-Type: the profile recommended for residential lighting Set up for D01-Type in Smart timer dimming software program: T1 T2 T3 T4 TIME** 06:00 07:00 11:00 --- LEVEL** 100% 70% 50% 70% Dimming Level(%) Operating Time(HH:MM) **: TIME matches Operating Time in the diagram whereas LEVEL matches Dimming Level. Example: If a residential lighting application adopts D01-Type, when turning on the power supply at 6:00pm, for instance: [1] The power supply will switch to the constant current level at 100% starting from 6:00pm. [2] The power supply will switch to the constant current level at 70% in turn, starting from 0:00am, which is 06:00 after the power supply turns on. [3] The power supply will switch to the constant current level at 50% in turn, starting from 1:00am, which is 07:00 after the power supply turns on. [4] The power supply will switch to the constant current level at 70% in turn, starting from 5:00am, which is 11:00 after the power supply turns on. The constant current level remains till 8:00am, which is 14:00 after the power supply turns on. Ex: D02-Type: the profile recommended for street lighting Set up for D02-Type in Smart timer dimming software program: TIME** LEVEL** T1 01:00 50% T2 03:00 80% T3 8:00 100% T4 T5 11:00 --- 60% 80% Dimming Level(%) Operating Time(HH:MM) **: TIME matches Operating Time in the diagram whereas LEVEL matches Dimming Level. Example: If a street lighting application adopts D02-Type, when turning on the power supply at 5:00pm, for instance: [1] The power supply will switch to the constant current level at 50% starting from 5:00pm. [2] The power supply will switch to the constant current level at 80% in turn, starting from 6:00pm, which is 01:00 after the power supply turns on. [3] The power supply will switch to the constant current level at 100% in turn, starting from 8:00pm, which is 03:00 after the power supply turns on. [4] The power supply will switch to the constant current level at 60% in turn, starting from 1:00am, which is 08:00 after the power supply turns on. [5] The power supply will switch to the constant current level at 80% in turn, starting from 4:00am, which is 11:00 after the power supply turns on. The constant current level remains till 6:30am, which is 14:00 after the power supply turns on. File Name:ELG-100-SPEC 2024-01-08 E L G - 1 0 0 70~100W Constant Voltage + Constant Current LED Driver series Ex: D03-Type: the profile recommended for tunnel lighting Set up for D03-Type in Smart timer dimming software program: T1 T2 T3 TIME** 01:30 11:00 --- LEVEL** 70% 100% 70% Dimming Level(%) Operating Time(HH:MM) **: TIME matches Operating Time in the diagram whereas LEVEL matches Dimming Level. Example: If a tunnel lighting application adopts D03-Type, when turning on the power supply at 4:30pm, for instance: [1] The power supply will switch to the constant current level at 70% starting from 4:30pm. [2] The power supply will switch to the constant current level at 100% in turn, starting from 6:00pm, which is 01:30 after the power supply turns on. [3] The power supply will switch to the constant current level at 70% in turn, starting from 5:00am, which is 11:00 after the power supply turns on. The constant current level remains till 6:30am, which is 14:00 after the power supply turns on. File Name:ELG-100-SPEC 2024-01-08 E L G - 1 0 0 70~100W Constant Voltage + Constant Current LED Driver series OUTPUT LOAD vs TEMPERATURE(Note.9) LOAD (%) THD LOAD (%) 100 80 230VAC input only 60 40 20 -40 -25 -10 0 15 30 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE,Ta () LOAD (%) 100 80 230VAC input only 60 40 20 -40 -25 0 10 30 50 70 Tcase () 85 90 (HORIZONTAL) STATIC CHARACTERISTIC 100 90 80 70 60 50 40 100 120 140 160 180 200 240 250 260 270 280 305 INPUT VOLTAGE (V) 60Hz De-rating is needed under low input voltage. PF POWER FACTOR (PF) CHARACTERISTIC Tcase at 80 Constant Current Mode 1 0 .9 8 0 .9 6 0 .9 4 0 .9 2 0 .9 0 .8 8 0 .8 6 50% 60% 70% 80% 90% 100% LOAD 2 7 7 V(1 0 0 W) 2 3 0 V(1 0 0 W) 115V(70W ) TOTAL HARMONIC DISTORTION (THD) 54V Model, Tcase at 80 22% 20% 18% 16% 14% 12% 10% 8% 6% 4% 2% 50% 60% 70% 80% 2 7 7 VAC (1 0 0 W) 2 3 0 VAC (1 0 0 W) 1 1 5 VAC (7 0 W ) 90% 100% LOAD EFFICIENCY(%) EFFICIENCY vs LOAD ELG-100 series possess superior working efficiency that up to 91% can be reached in field applications. 54V Model, Tcase at 80 94 92 90 277V(100W) 88 230V(100W) 86 115V(870W) 84 82 80 50% 60% 70% 80% 90% 100% LOAD File Name:ELG-100-SPEC 2024-01-08 E L G - 1 0 0 70~100W Constant Voltage + Constant Current LED Driver series LIFE TIME LIFETIME(Kh) 120 100 80 60 40 20 0 20 30 40 50 60 70 80 90 Tcase ( ) File Name:ELG-100-SPEC 2024-01-08 E L G - 1 0 0 70~100W Constant Voltage + Constant Current LED Driver series Mechanical Specification Blank-Type CASE NO.: 244A Unit:mm 199 188 300±20 175 300±20 AC/N(Blue) AC/L(Brown) SJOW 17AWGx2C &H05RN-F 1.0mm2 tc 105 4-4.5 tc : Max. Case Temperature SJOW 17AWGx2C &05RN-F 1.0mm2 Vo-(Black) Vo+(Red) 63 45.8 20 35 35.5 A-Type 300±20 AC/N(Blue) AC/L(Brown) SJOW 17AWGx2C &H05RN-F 1.0mm2 63 45.8 20 199 188 175 tc 105 4-4.5 tc : Max. Case Temperature 300±20 SJOW 17AWGx2C &05RN-F 1.0mm2 Vo-(Black) Vo+(Red) 35 35.5 21.5 14 33 File Name:ELG-100-SPEC 2024-01-08 E L G - 1 0 0 70~100W Constant Voltage + Constant Current LED Driver series AB-Type 199 188 300±20 175 63 45.8 20 AC/N(Blue) AC/L(Brown) SJOW 17AWGx2C &H05RN-F 1.0mm2 tc 105 4-4.5 tc : Max. Case Temperature 300±20 UL2517 20AWGx2C SJOW 17AWGx2C &05RN-F 1.0mm2 DIM+(Purple) DIM-(Pink) Vo-(Black) Vo+(Red) 35 35.5 21.5 14 33 B/DA/D2-Type 199 188 300±20 175 AC/N(Blue) AC/L(Brown) SJOW 17AWGx2C &H05RN-F 1.0mm2 tc 105 4-4.5 tc : Max. Case Temperature 300±20 UL2517 20AWGx2C SJOW 17AWGx2C &05RN-F 1.0mm2 DIM+(Purple)* DIM-(Pink)** Vo-(Black) Vo+(Red) * DIM+ for B-Type DA+ for DA-Type PROG+ for D2-Type * *DIM- for B-Type DA- for DA-Type PROG- for D2-Type 63 45.8 20 35 35.5 File Name:ELG-100-SPEC 2024-01-08 E L G - 1 0 0 70~100W Constant Voltage + Constant Current LED Driver series 3Y Model (3-wire input) 199 188 300±20 175 63 45.8 20 AC/N(Blue) AC/L(Brown) PE (Green/Yellow) SJOW 17AWGx3C &H05RN-F 1.0mm2 tc 105 4-4.5 tc : Max. Case Temperature Note1: Please connect the case to PE for the complete EMC deliverance and safety use. Note2: Please contact MEAN WELL for input wiring option with PE. Recommend Mounting Direction SJOW 17AWGx2C &05RN-F 1.0mm2 INSTALLATION MANUAL Please refer to:http://www.meanwell.com/manual.html File Name:ELG-100-SPEC 2024-01-08