User Guide for FISHER PAYKEL models including: DE8060P2, Front Loader Washing Machine and Dryer, DE8060P2 Front Loader Washing Machine and Dryer

FRONT LOADER WASHING MACHINE ... - Fisher & Paykel

10 août 2021 — 1 Dryer cold water inlet hose is only present on DH9060FS model dryers. * Cold water inlet hoses can be interchanged between washer and dryer.

Pairing Guide

Heat Pump Condensing Dryer, 9kg, Steam Care


File Info : application/pdf, 16 Pages, 1.52MB

PDF preview unavailable. Download the PDF instead.

FP-InstallGuide-en-WH-DE-DH-FrontLoaderWashingMachineAndDryer-PairingGuide-428281B-NZ-AU-SG-UK-IE-EU
FRONT LOADER WASHING MACHINE & DRYER PAIRING GUIDE
INSTALLATION GUIDE

MODELS WH1260F1 WH1160F2 WH1160FG2 WH1060S1 WH1160S1 WH1060SG1 WH1160P3 WH1060P1 WH1260P1 WH7560P2 WH7560J3 WH8060J3 WH8560F1 WH8060P2 WH8560P2 WH9060J3 WH8560J3 WH8060P1 WH9060P3 WH1060P3 WH8560P3 WH8060P3

DE8060P2
· · · · · · · · ·

DE8060P3
· · · ·

SIDE BY SIDE INSTALL ­ PAIRING MATRIX

DH8060P1
· · · · · · · · ·

DH8060P3
· · · ·

DRYERS

DH9060P1

DH9060P2

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

DH9060PG2 ·

DH9060C1 · · · · ·
· · ·

DH9060FS1 · · · · ·

DH9060FSG1 · · · · ·

·

·

·

·

·

·

WASHERS

· Matched Pair ­ designed to complement each other · Perfect Pair ­ designed to mirror each other

Compatible

2

STACKED INSTALL ­ PAIRING MATRIX

WASHERS

MODELS
WH1260F1 WH1160F2 WH1160FG2 WH1060S1 WH1160S1 WH1060SG1 WH1160P3 WH1060P1 WH1260P1 WH7560P2 WH7560J3 WH8060J3 WH8560F1 WH8060P2 WH8560P2 WH9060J3 WH8560J3 WH8060P1 WH9060P3 WH1060P3 WH8560P3 WH8060P3

DE8060P2
· · · · · · · · ·

DE8060P3

DH8060P1

STACKING KIT 428122

· · · · · · · · · · · · ·

DH8060P3
· · · ·

DRYERS

DH9060P1

DH9060P2

DH9060PG2

DH9060C1

DH9060FS1

STACKING KIT 428159 (WHITE), 99373 (GRAPHITE)

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

DH9060FSG1
· · · · ·
· · · X X X

· Matched Pair

X Not suitable for stacked install ­ potential safety risk

· Perfect Pair

Compatible

3

Front Loading Washer
WH1260, WH1160, WH1060P1, WH1060S

SIDE BY SIDE INSTALL ­ CLEARANCE & CAVITY DIMENSIONS
Heat Pump or Condensing Dryer DH9060, DE8060, DH8060

e

f

1 Front panel of the product

c

g

g

b FRONT

g d

a

g
c
PROFILE WASHER 4

g

CAVITY DIMENSIONS

MM

A Minimum cavity height

870

g

B Minimum cavity width

1260

d

C Minimum cavity depth

z Flush with front panel of the product1

655

z In cupboard

715

a
g c PROFILE DRYER

CLEARANCE DIMENSIONS
D Depth of door (widest opening, deepest product)
E Minimum washer door clearance to adjacent wall
F Minimum dryer door clearance to adjacent wall G Minimum gap clearance to adjacent product
or cabinetry2
2 Applies to sides, top, rear and between products

MM 450 355 335
20

Front Loading Washer WH1260, WH1160, WH1060P1, WH1060S
Water Supply
c

SIDE BY SIDE INSTALL ­ PLUMBING & ELECTRICIAL

Heat Pump or Condensing Dryer DH9060, DE8060, DH8060

Power Supply

b

a

ELECTRICAL Supply Service

SPECIFICATIONS
220­240 V, 50 Hz 10 amp circuit

PLUMBING Pressure Flow rate at tap

max 1 MPa (150psi) min 30 kPa (4.5psi) min 50 kPa (7.3psi)1
min. 6 litres/minute

Cold water temp

max 35°C

Hot water temp

max 65°C

Hot water inlet may not be an option for your washer model, refer to your washer installation guide.
1 WH1260F, WH1160F, WH1160S, WH1060S

d

cc

b

a

WASHER

DRYER

WASHER DRAINAGE HEIGHTS

SERVICE DIMENSION
A Length of drain hoses B Length of power cord C Length of cold water inlet hose1 D Length of hot water inlet hose
1 Dryer cold water inlet hose is only present on DH9060FS model dryers * Cold water inlet hoses can be interchanged between washer and dryer

WASHER MM
1600 2000 1500 1500

DRYER MM
1300 1500 650*
n/a

* Recommended standpipe height is 800mm

600mm min 1000mm max*

5

Front Loading Washer WH8060J, WH7560

SIDE BY SIDE INSTALL ­ CLEARANCE & CAVITY DIMENSIONS
Heat Pump or Condensing Dryer DH9060, DE8060, DH8060

e

f

1 Front panel of the product

c

g

g

b FRONT

g d

a

g
c
PROFILE WASHER 6

g

CAVITY DIMENSIONS

MM

A Minimum cavity height

870

g

B Minimum cavity width

1260

d

C Minimum cavity depth

z Flush with front panel of the product1

640

z In cupboard

705

a
g c PROFILE DRYER

CLEARANCE DIMENSIONS
D Depth of door (widest opening, deepest product)
E Minimum washer door clearance to adjacent wall
F Minimum dryer door clearance to adjacent wall G Minimum gap clearance to adjacent product
or cabinetry2
2 Applies to sides, top, rear and between products

MM 450 355 335
20

Front Loading Washer WH8060J, WH7560
Water Supply
c

SIDE BY SIDE INSTALL ­ PLUMBING & ELECTRICIAL

Heat Pump or Condensing Dryer DH9060, DE8060, DH8060

Power Supply

b

a

ELECTRICAL Supply Service

SPECIFICATIONS
220­240 V, 50 Hz 10 amp circuit

PLUMBING Pressure Flow rate at tap

max 1 MPa (150psi) min 30 kPa (4.5psi)
min. 6 litres/minute

Cold water temp

max 35°C

Hot water temp

max 65°C

Hot water inlet may not be an option for your washer model, refer to your washer installation guide.

d

cc

b

a

WASHER

DRYER

SERVICE DIMENSION
A Length of drain hoses B Length of power cord C Length of cold water inlet hose1 D Length of hot water inlet hose2
1 Only present for DH9060FS model dryers 2 Only present for WH7560P2 model washers * Cold water inlet hoses can be interchanged between washer and dryer

WASHER MM
1600 1500 1500 1500

DRYER MM
1300 1500 650*
n/a

WASHER DRAINAGE HEIGHTS
* Recommended standpipe height is 800mm

600mm min 1000mm max*

7

Front Loading Washer WH1060P3, WH9060, WH8560 WH8060P

SIDE BY SIDE INSTALL ­ CLEARANCE & CAVITY DIMENSIONS
Heat Pump or Condensing Dryer DH9060, DE8060, DH8060

e

f

1 Front panel of the product

c

g

g

b FRONT

g d

a

g
c
PROFILE WASHER 8

g

CAVITY DIMENSIONS

MM

A Minimum cavity height

870

g

B Minimum cavity width

1260

d

C Minimum cavity depth

z Flush with front panel of the product1

650

z In cupboard

705

a
g c PROFILE DRYER

CLEARANCE DIMENSIONS
D Depth of door (widest opening, deepest product)
E Minimum washer door clearance to adjacent wall
F Minimum dryer door clearance to adjacent wall G Minimum gap clearance to adjacent product
or cabinetry2
2 Applies to sides, top, rear and between products

MM 450 355 335
20

Front Loading Washer WH1060P3, WH9060, WH8560 WH8060P
Water Supply
c

SIDE BY SIDE INSTALL ­ PLUMBING & ELECTRICIAL

Heat Pump or Condensing Dryer DH9060, DE8060, DH8060

Power Supply

b

a

ELECTRICAL Supply Service

SPECIFICATIONS
220­240 V, 50 Hz 10 amp circuit

PLUMBING Pressure Flow rate at tap

max 1 MPa (150psi) min 30 kPa (4.5psi)
Min. 6 litres/minute

Cold water temp

max 35°C

Hot water temp

max 65°C

Hot water inlet may not be an option for your washer model, refer to your washer installation guide.

d

cc

b

a

WASHER

DRYER

SERVICE DIMENSION
A Length of drain hoses B Length of power cord C Length of cold water inlet hose1 D Length of hot water inlet hose2
1 Only present for DH9060FS model dryers 2 Only present for WH8060 * Cold water inlet hoses can be interchanged between washer and dryer

WASHER MM
1500 1500 1500 1500

DRYER MM
1300 1500 650*
n/a

WASHER DRAINAGE HEIGHTS
* Recommended standpipe height is 800mm

600mm min 1000mm max*

9

Front Loading Washer WH1260, WH1160, WH1060P1, WH1060S

Heat Pump Dryer DH9060

f

STACKED INSTALL ­ CLEARANCE & CAVITY DIMENSIONS
Stacking kit 428159 (white) & 99373 (graphite)
1 Front panel of the product
c g d

e

Stacking kit

Stacking kit

a

g

g

b

FRONT

10

d c
PROFILE

CAVITY DIMENSIONS A Minimum cavity height B Minimum cavity width C Minimum cavity depth z Flush with front panel of the product1 z In cupboard
CLEARANCE DIMENSIONS D Depth of door (widest opening, deepest product) E Minimum washer door clearance to adjacent wall F Minimum dryer door clearance to adjacent wall G Minimum gap clearance to adjacent product
or cabinetry2
2 Applies to sides, top, rear and between products

MM 1750 640
655 715
MM 450 355 335
20

Front Loading Washer WH1260, WH1160, WH1060P1, WH1060S
Power Supply
Water Supply

STACKED INSTALL ­ PLUMBING & ELECTRICIAL

Heat Pump Dryer DH9060

Stacking kit
428159 (white) & 99373 (graphite)

bA DRYER

Drain Hose

Heat pump Dryer
Stacking Kit

ELECTRICAL Supply Service

SPECIFICATIONS
220­240 V, 50 Hz 10 amp circuit

PLUMBING Pressure Flow rate at tap

max 1 MPa (150psi) min 30 kPa (4.5psi) min 50 kPa (7.3psi)1
min. 6 litres/minute

Cold water temp

max 35°C

Hot water temp

max 65°C

Hot water inlet may not be an option for your washer model, refer to your washer installation guide.
1 WH1260F, WH1160F, WH1160S, WH1060S

c

WASHER DRAINAGE HEIGHTS

Washer

D cc

WASHER

b

A

SERVICE DIMENSION
A Length of drain hoses B Length of power cord C Length of cold water inlet hose1 D Length of hot water inlet hose
1 Only present for DH9060FS model dryers * Cold water inlet hoses can be interchanged between washer and dryer

WASHER MM
1600 2000 1500 1500

DRYER MM
1300 1500 650*
n/a

* Recommended standpipe height is 800mm

11

600mm min 1000mm max*

Front Loading Washer WH8060J, WH7560

Heat pump Dryer DE8060, DH8060P

STACKED INSTALL ­ CLEARANCE & CAVITY DIMENSIONS
Stacking kit 428122

f

g

d

1 Front panel of the product
c

e

Stacking kit

Stacking kit

a

g

g

b

FRONT

12

d c
PROFILE

CAVITY DIMENSIONS A Minimum cavity height B Minimum cavity width C Minimum cavity depth z Flush with front panel of the product1 z In cupboard
CLEARANCE DIMENSIONS D Depth of door (widest opening, deepest product) E Minimum washer door clearance to adjacent wall F Minimum dryer door clearance to adjacent wall G Minimum gap clearance to adjacent product
or cabinetry2
2 Applies to sides, top, rear and between products

MM 1750 640
635 685
MM 450 355 335
20

Front Loading Washer WH8060J, WH7560
Power Supply
Water Supply

STACKED INSTALL ­ PLUMBING & ELECTRICIAL

Heat pump Dryer DE8060, DH8060P

Stacking kit 428122

bA DRYER

Drain Hose

Heat pump Dryer
Stacking Kit

ELECTRICAL Supply Service
PLUMBING Pressure Flow rate at tap Cold water temp Hot water temp

SPECIFICATIONS
220­240 V, 50 Hz 10 amp circuit
max 1 MPa (150psi) min 30 kPa (4.5psi) min. 6 litres/minute max 35°C max 65°C

Washer

WASHER DRAINAGE HEIGHTS

Dc

WASHER

b

A

SERVICE DIMENSION
A Length of drain hoses B Length of power cord C Length of cold water inlet hose1 D Length of hot water inlet hose2
1 Only present for DH9060FS model dryers 2 Only present for WH7560P2 model washers

WASHER MM
1600 1500 1500 1500

DRYER MM
1300 1500
n/a n/a

* Recommended standpipe height is 800mm

13

600mm min 1000mm max*

Front Loading Washer
WH1060P3, WH9060 WH8560, WH8060P

Heat Pump or Condensing Dryer
DE8060, DH8060P

f

STACKED INSTALL ­ CLEARANCE & CAVITY DIMENSIONS
Stacking kit 428122

g d

1 Front panel of the product
c

e

Stacking kit

Stacking kit

a

g

g

b

FRONT

14

d c
PROFILE

CAVITY DIMENSIONS A Minimum cavity height B Minimum cavity width C Minimum cavity depth z Flush with front panel of the product1 z In cupboard
CLEARANCE DIMENSIONS D Depth of door (widest opening, deepest product) E Minimum washer door clearance to adjacent wall F Minimum dryer door clearance to adjacent wall G Minimum gap clearance to adjacent product
or cabinetry2
2 Applies to sides, top, rear and between products

MM 1750 640
650 695
MM 450 355 335
20

Front Loading Washer WH1060P3, WH9060 WH8560, WH8060P
Power Supply
Water Supply

STACKED INSTALL ­ PLUMBING & ELECTRICIAL

Heat Pump or Condensing Dryer
DE8060, DH8060P

Stacking kit 428122

bA DRYER

Drain Hose

Heat pump Dryer
Stacking Kit

ELECTRICAL Supply Service
PLUMBING Pressure Flow rate at tap Cold water temp Hot water temp

SPECIFICATIONS
220 -240 V, 50 Hz 10 amp circuit
max 1 MPa (150psi) min 30 kPa (4.5psi) min. 6 litres/minute max 35°C max 65°C

Washer

WASHER DRAINAGE HEIGHTS

Dc

WASHER

b

A

SERVICE DIMENSION
A Length of drain hoses B Length of power cord C Length of cold water inlet hose1 D Length of hot water inlet hose2
1 Only present for DH9060FS model dryers 2 Some models of washer only

WASHER MM
1500 1500 1500 1500

DRYER MM
1300 1500
n/a n/a

* Recommended standpipe height is 800mm

15

600mm min 1000mm max*

FISHERPAYKEL.COM
© Fisher & Paykel Appliances 2021. All rights reserved. The models shown in this guide may not be available in all markets
and are subject to change at any time. The product specifications in this guide apply to the specific products and models described at the date of issue. Under our policy of continuous product
improvement, these specifications may change at any time. For current details about model and specification availability in your country,
please go to our website or contact your local Fisher & Paykel dealer.
428281B 12.21



References

Adobe PDF Library 16.0.3 Adobe InDesign 17.0 (Macintosh)