RISCO eyeWAVE™ Wireless PIR Camera

Models: RWX95CM/RWX95CMP

Description

The eyeWAVE™ Wireless PIR Camera Detector is a battery-powered PIR detector with an integrated camera for visual verification. It is compatible with RISCO security systems.

Features:

Installation

Step 1: Preliminary Considerations

Step 2: Registering the Detector into the System

The eyeWAVE must identify itself to the system receiver through a device allocation (enrollment) process. This can be done via RF sequence registering, entering the detector’s 11-digit serial number, or using RF mode panel quick key programming.

From the panel: 2) Radio Devices > 1) Allocation > 1) By RF or 2) By Code.

Through the Configuration Software: Radio Device Allocation > Enter Serial Code: [045] + [8 digits]; Indexed: Automatic or manually designated 1-32; Accessory Type: 2-Way Detector. Then click Allocate.

Refer to the System Installer Manual for more information.

Step 3: Mounting the Detector

  1. Open the knockout holes of the mounting bracket and use them as a template for mounting.
  2. Fasten the cover to the base of the detector by inserting and fastening the screw into the hole located inside the battery compartment.
  3. Insert the batteries and close the battery compartment cover.
  4. Once the bracket is installed, slide and lock the detector onto the mounting bracket in reverse sequence.
  5. Perform a Walk Test as described in the Walk Test section.
  6. Insert and fasten screw (C) into the hole located at the bottom of the detector to lock the detector to the mounting bracket.

Step 4: Performing a Walk Test

To manually initiate a walk test from the control panel:

Installation Menu: 2) Testing > 2) Zone > 3) Walk Test > 1) Start Walk Test.

The detector remains in walk test mode until any key on the panel is pressed. Display test results as follows: Installation Menu: 2) Testing > 2) Zone > 3) Walk Test > 2) Walk Test Results.

Camera Configuration

Detector parameters can be modified from the keypad or the system configuration software.

PIR Settings:

Configure camera settings through the RISCO Configuration Software (right-click on the Serial Code field in the Zones node screen and click Additional..) or through the panel quick key programming sequence:

Programming > 2) Radio Devices > 2) Modification > 1) Zone [Select (1–32)] > 1) Parameters > 6) Advanced > 5) Camera Parameters:

Image upon request

Snapshot images can be taken using web/smartphone apps (on panels supporting these applications).

Event Reporting

Every event detected by the PIR camera is recorded into the camera’s memory, including date, time, event description, source, and a video record.

LED Status

Diagnostics

Diagnostic tests can be performed on the detector using the keypad or configuration software to check battery status and communication with the panel. Refer to the System Installer Manual for details.

Battery Replacement

A low battery condition is indicated by a blinking LED on each transmission.

  1. Remove the detector from the mounting bracket.
  2. Open the battery cover.
  3. Replace the batteries, paying attention to polarity.
  4. Close the battery cover.

CAUTION: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to local regulations.

Specifications

Electrical

Optical

Physical

Environmental

Camera

Approvals

Ordering Information

RED Compliance Statement

Hereby, RISCO Group declares that this equipment is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. For the CE Declaration of Conformity please refer to our website: www.riscogroup.com.

Standard Limited Product Warranty

RISCO Ltd. guarantees its hardware products to be free from defects in materials and workmanship for a period of 24 months from the date of connection to the RISCO Cloud or from production date (for non-cloud connected products).

This warranty is for the benefit of the customer who purchased the product directly from RISCO or an authorized distributor. RISCO customer shall handle all interactions with its end users regarding the warranty.

Return Material Authorization: Customer must obtain an RMA number from RISCO prior to returning any product. The returned product must include a detailed description of the defect.

Limitations: The warranty does not apply if products have been subjected to improper operation, installation, neglect, abuse, alteration, modification, or repair without RISCO’s written approval, or damage from factors beyond RISCO’s control.

Batteries are explicitly excluded from the warranty.

RISCO disclaims all other warranties, expressed or implied, including warranties of merchantability or fitness for a particular purpose.

RISCO is not responsible for the performance of the end-user security system or for any personal injury or property loss. Correctly installed and maintained alarm systems may reduce risk but do not guarantee against events.

Contacting RISCO Group:

Models: RWX95CM, RWX95CMP, eyeWAVE Wireless PIR Camera

File Info : application/pdf, 2 Pages, 707.22KB

PDF preview unavailable. Download the PDF instead.

eyeWAVE Wireless Camera PIR Installer Manual

References

Acrobat Distiller 11.0 (Windows)

Related Documents

Preview RISCO iWISE RK815DTGL/RK825DTGL Motion Detector Installation and Technical Specifications
Comprehensive guide to the RISCO iWISE RK815DTGL and RK825DTGL motion detectors, covering installation, jumper settings, technical specifications, features like ACT™ and Green Line, and warranty information.
Preview LuNAR 150DTG3 Ceiling Motion Detector Installation and Technical Guide
Comprehensive guide for the RISCO LuNAR 150DTG3 ceiling motion detector, covering installation, maintenance, technical specifications, jumper settings, terminal wiring, LED indicators, and warranty information.
Preview RISCO Curtain Outdoor Swivel Installation Guide and Warranty
Comprehensive installation instructions for RISCO Curtain Outdoor Swivel accessories, covering wall and ceiling mounting for wireless and wired detectors, along with the RISCO Standard Limited Product Warranty.
Preview RISCO RK66S Seismic Detector Installation Instructions
Comprehensive installation guide for the RISCO RK66S Seismic Detector, detailing features, mounting procedures, wiring, dipswitch settings, and testing for both Stand Alone and BUS modes.
Preview RISCO Wi-Fi Video Doorbell Camera & Wireless Chime: Installation Guide & Setup
Comprehensive installation guide for the RISCO RVDBA701000A Wi-Fi Video Doorbell Camera and Wireless Chime. Learn how to set up, connect to Wi-Fi, and configure settings using the iRISCO app. Includes wiring diagrams and specifications.
Preview RISCO Video Doorbell RVDBA701009A: HD Video, Two-Way Audio, Night Vision
Discover the RISCO Video Doorbell (RVDBA701009A), a WiFi-enabled camera with HD video, two-way audio, motion detection, and night vision. Enhance home and business security with seamless integration and easy installation.
Preview RISCO LightSYS Plus Plastic Box Installation Guide and Warranty
Comprehensive installation instructions for the RISCO LightSYS Plus Plastic Box (Model RP432BP), including detailed steps, multilingual support, and the Standard Limited Product Warranty.
Preview RISCO LCD Panda Keypad & Proximity Keypad: Installation and User Guide
Comprehensive installation and user guide for the RISCO LCD Panda Keypad and LCD Panda Proximity Keypad, covering features, setup, configuration, and technical specifications for security systems.