User Guide for Nureva models including: RM-CG, AI-BOX1, Lumens PTZ Camera, HDL300 Sound Location Sata Enable Tracking for Lumens PTZ Cameras, HDL300, Sound Location Sata Enable Tracking for Lumens PTZ Cameras, Sata Enable Tracking for Lumens PTZ Cameras, Tracking for Lumens PTZ Cameras, Lumens PTZ Cameras, PTZ Cameras

CamConnect Pro Solutions for Yamaha RM-CG

John.Wei(377韋之洛)

CamConnect Pro (AI-Box1) - Nureva HDL300 Setting GuideInstallation Guide

Installation Guide | Lumens

[PDF] Nureva HDL300 Settings Guide - Mylumens

B. A: Enter the Nureva device's IP. B: Press [Apply] and the toggle [connect] bar to enable. ※Nureva's default port is 8931. Please confirm the port is.


File Info : application/pdf, 11 Pages, 1.67MB

PDF preview unavailable. Download the PDF instead.

Nureva HDL300 Setting Guide 2024-0807
Nureva HDL300 Settings Guide

Nureva HDL300 1. Hardware Connections
Copyright © Lumens. All rights reserved.

1.1 Hardware Connections
Nureva HDL300 Microphone

Cable define Cat5e HDMI cable USB 2.0 cable

HDL300 connect module

CamConnect Processor (AI-BOX1)

Display

Meeting Room PC (Windows OS)

Display

Lumens PTZ Camera
Copyright © Lumens. All rights reserved.

Nureva HDL300 2. Install Nureva Console client
Copyright © Lumens. All rights reserved.

2.1 Install Nureva Console client
Download [Console Client] https://support.nureva.com/97341-download/win-mac-download-
nureva-console-client
Copyright © Lumens. All rights reserved.

2.2 Set up Nureva Console client
Install Nureva Console client then launch the Console client app. Connect the Nureva connect module to the PC with a USB cable.
Copyright © Lumens. All rights reserved.

2.3 Set up Nureva HDL300 integration
A
B C
A: Pull the vertical scroll bar of the Console client down B: Go to the 'Integrations' option and expand [Local integrations]
Copyright © Lumens. All rights reserved.

2.4 Setup camera tracking integration

A B
A: Enable [Network integration settings] B: Copy the IP address (C)

C
Copyright © Lumens. All rights reserved.

2.5 Setup camera tracking integration

A B

A: Enter the Nureva device's IP
B: Press [Apply] and the toggle [connect] bar to enable Nureva's default port is 8931. Please confirm the port is permitted to connect with your PC.

Copyright © Lumens. All rights reserved.

3. Set angle positions
Copyright © Lumens. All rights reserved.

3.1 Set angle positions

70

-70

0

Note: The maximum "Azimuth Angle" range is -70 to +70 degrees. 0-degrees is the center point. The diagram above shows a sound source detected in the 0-degree region.
Copyright © Lumens. All rights reserved.



References