Instructions for legrand models including: LE13949AB, 0 485 73, LE13949AB Multi Sensor Detector, LE13949AB, Multi Sensor Detector, Sensor Detector
File Info : application/pdf, 1 Pages, 464.64KB
DocumentDocumentTECHNICAL GUIDE LE13949AB S000124565_2 LIGHT UP · LIGHT UP Détecteur DALI Multi-capteurs 3 zones · LIGHT UP Multisensor DALI 3 zones Detector 0 485 73 · Documentation technique disponible dans votre langue => Scanner le QR code · Technical documentation available in your language => Scan the QR code · Documentación técnica disponible en su idioma => Escanear el cdigo QR · Documentazione tecnica disponibile nella vostra lingua => Scansionare il codice QR · Technische documentatie beschikbaar in jouw taal. => Scan de QR-code FR Legrand CLOSE UP GB · Notice · Instruction Sheet 110 - 230 V~ 50 / 60 Hz 2 x 1.5 mm² ou/or 1 x 2.5 mm² +5°C / +30°C PIR 300 lux · Capteur de luminosité · Daylight sensor · Capteur d'humidité · Humidity sensor · Capteur sonore · Sound sensor · Mode Passage · Walktrough mode 15 min. 5 1275 lux 20 % 80 % 38 120 dB SPL Hauteur/Height 2.5 m 1.7 m mini - Ø 12 m (2.5 m) ES 5.0 compatible 4.2 · Portée : 10 m · Reach: 10 m Radio 2.4 - 2.483 GHz Garantie/ Guaranteed Maximum 16 V 100 mA 16 V 130 mA · Nombre de ballast maximun · Maximum number of ballast units 50 · Consommation en veille : · Standby consumption : · Capteur de température · Temperature sensor · Capteur COVt · VOCt sensor · Niveau Qualité de l'air · IAQ level · Niveau de CO2 estimé · Estimated CO2 level Charge/Load OFF Charge/Load ON 1,15 W 1,9 W 0°C / +50°C 0 10 000 ppb 1.0 5.0 400 5000 ppm IT NL · Instrucciones de Uso · Foglio Istruzioni · Gebruiksaanwijzing 128, av. du Maréchal-de-Lattre-de-Tassigny - 87045 LIMOGES Cedex - France Tel: +33(0)5 55 06 87 87 - Fax: +33(0)5 55 06 88 88 www.legrandgroup.com LIGHT-UP 3-zone DALI multisensor advanced detector Cat. No(s): 0 485 73 Access to the full LIGHT UP documentation CONTENTS PAGE 1. Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. Technical characteristics . . . . . . . . . . . . . . . . .1 3. Declaration of conformity . . . . . . . . . . . . . . . .2 4. Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 5 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 6. Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 7. Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 8. Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 9. Detection zone . . . . . . . . . . . . . . . . . . . . . . . . . .5 10. PIR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 11. Measuring the light level . . . . . . . . . . . . . . . .5 12. Reducing the detection zone . . . . . . . . . . .6 13. Settings with Close Up . . . . . . . . . . . . . . . . . .6 14. Description of buttons and LEDs . . . . . . . .8 15. Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 16. Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 17. SURFACE MOUNTING . . . . . . . . . . . . . . . . . . .9 18. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . 10 1. USE This product is a presence detector, which allows light sources to be controlled automatically and it is equipped with environmental sensors. The mounting position is on the ceiling, it has a 360° detection angle. It has: · The option of being paired with a wireless batteryless switch and/or controlling a connected power outlet. · 1 auxiliary input for priority lighting using the wired push-button connected to the line. · 1 motion sensor (PIR technology) with lens for detecting occupancy. · 1 daylight sensor which allows it to regulate the light level automatically. · 1 temperature sensor which measures the room temperature in degrees Celsius. · 1 relative humidity sensor which measures the relative humidity in the room as a percentage. · 1 sound level sensor which measures the ambient noise in dBspl. · 1 VOC which estimates the room indoor air quality. It measures the total volatile compounds in ppb, provides an air quality index such as the UBA index and estimates the level of CO2 in ppm called "eCO2". · 1 DALI output for supplying the bus and controlling diffuse lighting. · 1 relay output dedicated to providing power for DALI ECGs. 1.1 Bluetooth 5.0 (compatible from 4.2): · For commissioning the product in a connectable system using the Legrand CLOSE UP mobile app. 1.2 Radio (2.4 - 2.483 GHz): · Creation of a standalone system, can be used to pair one power outlet and/or one wireless batteryless switch. 1. USE (continued) 1.3 Management of 3 lighting zones: LIGHT UP 3-zone DALI sensors can control 3 lighting zones: · "window" group dimming · "corridor" group dimming · "panel" group ON/OFF A wireless batteryless switch only controls the ON/OFF output in the "Panel" section. A wired push-button controls dimming in the two other zones. FR GB · Fiche Technique · User Manual Technical data sheet: S00120132EN-2 Updated: LIGHT UP DETECTORS Created: 18/11/2024 1/11 PROCEDURES MANUAL SEPTEMBER 2024 GLOBAL SPECIALIST IN ELECTRICAL AND AND DIGITAL BUILDING INFRASTRUCTURES FR · Guide Technique GB · User Manual