Instruction Manual for SIEMENS models including: SIM-16, SIM-16 Supervised Input Module, Supervised Input Module, Input Module, Module
Siemens SIM-16 Supervised Input Module, Installation Instructions - Fire Alarm Resources - Free fire alarm PDF manuals, documents, installation instructions, and technical specifications
File Info : application/pdf, 4 Pages, 677.42KB
DocumentDocumentInstallation Instructions Model SIM-16 Supervised Input Module INTRODUCTION The Model SIM-16 Supervised Input Module from Siemens Industry, Inc., is a remotely located, general purpose input module. It provides sixteen input circuits for remote system monitoring. Each input can be individually programmed as supervised (dry contacts only) or unsupervised (general-purpose input). The SIM-16 has two Form C relays. The relays and the inputs are programmable using the Zeus Programming Tool. TB1 SIM-16 12345678 9 10 11 12 13 14 15 16 P2 P3 23 23 456 S1 9 01 78 78 9 01 456 S2 OPERATION The SIM-16 is mounted in an enclosure that is remotely located from the Main Panel. Communication between the SIM-16 and the NIC-C (Network Interface Card) is through the Control Area Network (CAN) bus. Up to 99 SIM-16s can be used with a single NIC-C. Each SIM-16 has two 10-position rotary switches that are used to set the board address on the CAN which is a TB4 6 sub-address of the NIC-C. TB3 6 Every time a change of state of the input is detected, a unique CAN message is sent to the NIC-C. A CAN message from the NIC-C directed to the SIM-16 controls 1 the Form C relays. 1 12345678 9 10 11 12 13 14 15 16 PRE-INSTALLATION Rotary Address Switches - Set the board address for each SIM-16 using both of the ten-position rotary switches located on the board (See Figure 1). Each of these addresses must be a sub-address of the NIC-C and must be the same as the addresses assigned in the Zeus Programming Tool. TB2 Figure 1 SIM-16 Supervised Input Module INSTALLATION A SIM-16 may be installed in a REMBOX. When using REMBOX 2 or 4, mount the SIM-16 in one module space on a REMBOX2-MP, P/N 500-634211 or REMBOX4-MP, P/N 500-634212 using the four screws provided. (Refer to REMBOX2-MP/REMBOX4MP Installation Instructions, P/N 315-034211.) Up to 4 SIM-16s will fit in a REMBOX2; up to 8 SIM-16s will fit in a REMBOX4. P/N 315-034060-6 Siemens Industry, Inc. Building Technologies Division firealarmresources.com WIRING Refer to Figures 2-6. Remove all system power before installation, first battery then AC. (To power up, connect the AC first, then the battery.) · Each SIM-16 module is a node in the CAN bus. · The SIM-16 can be installed with or without an RNI. Connect the CAN bus and 24V as shown in Figures 2 and 3. · Up to 99 CAN modules, in any combination, can be connected to the CAN bus of each NIC-C. · Each SIM-16 module is shipped with one CCS cable. · Cable connections for SIM-16 modules are shown in the following table: SIM-16 CABLE CONNECTIONS Cable Description Part Number Connection CCL CCS CAN-CABLE-Long 599-634214 30 in., 6-conductor CAN-CABLE-Short 555-133539 5½ in., 6-conductor Connects P4 on RNI to first SIM-16. Also connects from SIM-16 to FCM/ LCM/SCM/CSB modules (on door). Connects SIM-16 modules to SIM-16 or OCM-16 modules in a single row The CAN bus requires a 120S termination at each end of the loop. Refer to the NIC-C Installation Instructions, P/N 315-033240 for details about CAN termination. TO RNI, P4 CABLE MODEL # CCL 23 23 23 23 23 23 23 23 TB1 12345678 9 10 11 12 13 14 15 16 P2 P3 456 S1 9 01 9 01 456 S2 78 78 78 78 78 78 78 78 CABLE MODEL # CCS TB1 12345678 9 10 11 12 13 14 15 16 P2 P3 TB1 12345678 9 10 11 12 13 14 15 16 P2 P3 456 S1 9 01 9 01 456 S2 456 S1 9 01 9 01 456 S2 TB1 12345678 9 10 11 12 13 14 15 16 P2 P3 456 S1 9 01 9 01 456 S2 CAN TERMINATOR, P/N 110-134215 (SHIPPED WITH NIC-C) SIM-16 SIM-16 SIM-16 SIM-16 TB4 TB4 TB4 TB4 6 6 6 6 TB3 TB3 TB3 TB3 6 6 6 6 1 1 1 1 1 1 1 1 12345678 9 10 11 12 13 14 15 16 12345678 9 10 11 12 13 14 15 16 12345678 9 10 11 12 13 14 15 16 12345678 9 10 11 12 13 14 15 16 TB2 TB2 TB2 TB2 Figure 2 SIM-16 CAN Bus Connections With An RNI Siemens Industry, Inc. Building Technologies Division 2 firealarmresources.com P/N 315-034060-6 NOTES 1. All wiring supervised. 2. All wiring power limited to NFPA 70 per NEC 760. 3. Wiring for TB1 and TB2 is 18 AWG min., 12 AWG max. 4. Wiring for TB3 and TB4 is 18AWG min., 16 AWG max. 5. CAN network max. line resistance 15S. 6. Refer to the NIC-C Installation Instructions, P/N 315-033240 for CAN network termination instructions. Figure 3 SIM-16 Wiring Without An RNI TO PSC-12/PSX-12, TB3 OR ANY REGULATED POWER LIMITED POWER SUPPLY LISTED FOR FIRE PROTECTIVE SIGNALING USE SIM-16 TO PSC-12, TB1 SEE NIC-C INSTALLATION INSTRUCTIONS, P/N 315-033240 FOR WIRING DETAILS TB3 +24 V 24 V RET SHIELD CAN + CAN SHIELD 16 15 14 13 12 11 10 9 87654321 TB2 NOTES 1. Contacts are unsupervised. 2. 1A max @ 24VDC resistive. 3. All wiring must remain inside the enclosure or within 20 feet in rigid conduit. 4. Wiring for TB1 and TB2 is 18 AWG min., 12 AWG max. 5. Wiring for TB3 and TB4 is 18AWG min., 16 AWG max. Figure 4 SIM-16 Relay Connections SIM-16 TB4 COM 6 TB3 Programmable Relay 2 N.C. 5 6 N.O. 4 Programmable Relay 1 COM 3 N.C. 2 N.O. 1 1 16 15 14 13 12 11 10 9 87654321 TB2 ELECTRICAL RATINGS Siemens Industry, Inc. Building Technologies Division 24V Back Plane Current 0 Screw Terminal 24V Current 20mA +1.2mA / supervised input +20mA / active relay 6.2V Back Plane Current 0 24V Standby Current 20mA +1.2mA / supervised input +20mA / active relay Output Power CAN Network Pair 8V peak to peak max. 75mA max. (during msg transmission) 3 firealarmresources.com P/N 315-034060-6 NOTES 1. All inputs supervised. 2. All inputs power limited to NFPA 70 per NEC 760. 3. Wiring for TB1 and TB2 is 18 AWG min., 12 AWG max. 4. Maximum distance 500 feet from SIM-16 to supervised input. 5. In the Zeus Programming Tool, select supervised for each supervised input. 6. Supervised and unsupervised inputs may be mixed on a single SIM-16. 7. Inputs #1 - 16 are programmable. Figure 5 SIM-16 Supervised Input Wiring TYPICAL *6.8K CONNECTION (16 PLACES) *SUPPLIED WITH THE SIM-16 TB1 12345678 9 10 11 12 13 14 15 16 INPUT #5 INPUT #2 INPUT #6 INPUT #9 SIM-16 16 15 14 13 12 11 10 9 87654321 TB2 INPUT #16 NOTES 1. All inputs unsupervised. 2. All inputs power limited to NFPA 70 per NEC 760. 3. Wiring for TB1 and TB2 is 18 AWG min., 12 AWG max. 4. All inputs must remain inside the enclosure or within 20 feet in rigid conduit. 5. In the Zeus Programming Tool, select unsupervised for each unsupervised input. 6. Supervised and unsupervised inputs may be mixed on a single SIM-16. 7. Inputs #1 - 16 are programmable. Figure 6 SIM-16 Unsupervised Input Wiring TYPICAL CONNECTION (16 PLACES) INPUT #1 INPUT #2 INPUT #5 TB1 12345678 9 10 11 12 13 14 15 16 INPUT #6 INPUT #9 SIM-16 16 15 14 13 12 11 10 9 87654321 TB2 INPUT #16 For CE applications in Cerberus E100 systems refer to Installation Instruction A24205-A334-B844 (English) or A24205-A334-A844 (German). Siemens Industry, Inc. Building Technologies Division Florham Park, NJ Siemens Building Technologies, Ltd. Fire Safety & Security Products 2 Kenview Boulevard Brampton, Ontario L6T 5E4 Canada Siemens Gebäudesicherheit GmbH & Co. oHG D-80930 München P/N 315-034060-6 firealarmresources.com