Installation Guide for Altronix models including: T3VK75F20 Trove Access and Power Integration, T3VK75F20, Trove Access and Power Integration, Access and Power Integration, Power Integration, Integration
Altronix T3VK75F20 | 20-Door Access and Power Integration Ki
File Info : application/pdf, 8 Pages, 1.04MB
DocumentDocumentAccess & Power Integration Altronix/HID VertX® Kits Models Include: T1VK3F4 4 Door Kit with Fused Outputs Fully assembled kit includes: - Trove1 enclosure with TV1 Altronix/HID VertX® backplane - One (1) eFlow6NB - Power Supply/Charger - One (1) VR6 - Voltage Regulator - One (1) PDS8 - Dual Input Fused Power Distribution Module T2VK7F8 8 Door Kit with Fused Outputs Fully assembled kit includes: - Trove2 enclosure with TV2 Altronix/HID VertX® backplane - One (1) eFlow104NB - Power Supply/Charger - One (1) ACM8 - Fused Access Power Controller - One (1) VR6 - Voltage Regulator - One (1) PDS8 - Dual Input Fused Power Distribution Module T3VK75F20 20 Door Kit with Fused Outputs Fully assembled kit includes: - Trove3 enclosure with TV3 Altronix/HID VertX® backplane - One (1) eFlow104NB - Power Supply/Charger - One (1) eFlow102NB - Power Supply/Charger - Two (2) ACM8 - Fused Access Power Controllers - One (1) ACM4 - Fused Access Power Controller - One (1) PD8UL - Fused Power Distribution Module - One (1) RSB2 - Rocker Switch Bracket with Two (2) Switches (Not evaluated by UL) All components of these Trove kits are UL Listed sub-assemblies. Please refer to the included corresponding Sub-Assembly Installation Guides for further information. Installation Guide All registered trademarks are property of their respective owners. More than just power.TM Rev. TVK_042519 Installing Company: _________________________ Service Rep. Name: __________________________________________ Address: _________________________________________________________ Phone #: _________________________ Overview: Altronix Trove HID VertX® kits are pre-assembled and consist of Trove enclosures/backplanes with factory installed Altronix power supply/ chargers and sub-assemblies. All kits accommodate a variety of HID VertX® modules for up to four (T1VK3F4), eight (T2VK7F8) or twenty (T3VK75F20) doors in a single enclosure. Configuration Chart: 120VAC 60Hz Input Current (A) Power Supply Board Input Fuse Rating Power Supply Board Battery Fuse Rating Fail-Safe/Fail-Secure or Dry Form "C" Outputs Additional Fused Outputs ACM4/ACM8 Board Input Fuse Rating ACM8 Board Output Fuse Rating ACM4 Board Output Fuse Rating PDS8 Board Input Fuse Rating PDS8 Board Output Fuse Rating PD8UL Board Output Fuse Rating Altronix Model Number T1VK3F4 T2VK7F8 T3VK75F20 Maximum Supply Current for Main Nominal DC Output Voltage and Aux. Outputs [DC] [Aux] on Power Supply board and ACM4/ Output Output ACM8 Access Power Range Range Controllers' outputs (VDC) (VDC) 3.5 5A/ 250V 15A/ 32V 24VDC @ 6A 20.17- 20.2826.4 26.4 4.5 6.3A/250V 15A/ 32V 24VDC @ 9.7A 20.17- 20.2826.4 26.4 8 eFlow104NB 7.5 6.3A/ 250V 15A/ eFlow102NB 32V 5A/ 250V 24VDC @ 9.1A 12VDC @ 10A 20.1726.4 9.713.2 20.2826.4 10.0313.2 20 8 10A/ 3A/ 32V 32V 8 10A/ 2.5A/ 250V 250V 10A/ 3A/ 32V 32V 8 10A/ 2.5A/ 3A/ 250V 250V 32V 3.5A/ 250V Installation Instructions for Trove1, Trove2, Trove3: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only. 1. Remove backplane from enclosure. Do not discard hardware. 2. Mark and predrill holes in the wall to line up with the top two/three keyholes in the enclosure. Install two/three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure's upper keyholes over the two/three upper screws, level and secure. Mark the position of the lower two/three holes. Remove the enclosure. Drill the lower holes and install the two/three fasteners. Place the enclosure's upper keyholes over the upper screws. Install the two/three lower screws and make sure to tighten all screws. 3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2" from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure. 4. Mount HID VertX® modules to backplane(s), refer to pages 3, 4, 5. Fig. 1 5. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow6NB, eFlow104NB, eFlow102NB and corresponding Sub-Assembly Installation Guides for Enclosure ACM4, ACM8, PDS8, VR6 and PD8UL for further installation instructions. Edge of Hardware: Enclosure Nylon Spacer | 7/8" Pan Head Screw | Lock Nut Tamper Switch (included) To Access Control Panel or UL Listed Reporting Device - 2 - Trove HID VertX (Fuse) Kits Installation Guide T1VK3F4: Installation Instructions for HID VertX® Access Controllers 1. Fasten spacers (provided) onto metal pems configuration (A) of backplane (Fig. 2, pg. 3). 2. Mount HID VertX® modules to spacers utilizing 7/8" pan head screws (provided) (Fig. 2a, pg. 3). 3. Fasten backplane to Trove1 enclosure utilizing hardware (provided). HID VertX® Access Controller Position Chart for the Following Models: Sub-Assembly Pem Mounting V100, V200, V300, V1000, V2000 A Fig. 2 Out8 <1 off 2> Out7 <1 off 2> Out6 <1 off 2> Out5 <1 off 2> Out4 <1 off 2> Out3 <1 off 2> Out2 <1 off 2> Out1 <1 off 2> IN2 Fuse + INP1 -- + INP2 -- L G N Altronix - eFlow6NB DM1 + OFF IN1 IN2 10 3 Altronix - PDS8 IN1 Fuse 10 3 3 3 3 3 DM1 + 33 P Common (--- ) OUT1 DM2 + N 1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 2 3 4 5 6 7 Common Power Outputs (NEG) OUT8 8 Common (--- ) DM2 + Altronix VR6 is mounted under PDS8 AC1 NC C NO NC C NO AC FAIL BAT FAIL ON AC DC OFF - 24V ON - 12V TRIGGER EOL NO GND SUPERVISED RESET +AUX- - BAT + - DC + A HID VertX® Module A HID VertX® Module Trove HID VertX (Fuse) Kits Installation Guide Fig. 2a Pem Spacer HID VertX® Pan Head Access Controller Screw Backplane - 3 - T2VK7F8: Installation Instructions for HID VertX® Access Controllers 1. Fasten spacers (provided) onto metal pems configuration (A) of backplane (Fig. 3, pg. 4). 2. Mount HID VertX® modules to spacers utilizing 7/8" pan head screws (provided) (Fig. 3a, pg. 4). 3. Fasten backplane to Trove2 enclosure utilizing hardware (provided). HID VertX® Access Controller Position Chart for the Following Models: Sub-Assembly Pem Mounting V100, V200, V300, V1000, V2000 A Fig. 3 DC + Altronix - eFlow104NB L G N INTERFACE NO C NC +INP- T + RET- TRIGGER INPUT IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 F1 F2 F3 F4 F5 F6 F7 F8 FACP TRG ON ON 1234 1234 FACP Altronix - ACM8 MAIN 10A 250V NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 -+-+ Power Control Altronix - PDS8 DM1 + OFF IN1 IN2 IN1 Fuse 10 DM1 + 10 3 3 3 3 3 3 3 3 Out8 <1 off 2> Out7 <1 off 2> Out6 <1 off 2> Out5 <1 off 2> Out4 <1 off 2> Out3 <1 off 2> Out2 <1 off 2> Out1 <1 off 2> IN2 Fuse + INP1 -- + INP2 -- P Common (--- ) OUT1 DM2 + N 1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 2 3 4 5 6 7 Common Power Outputs (NEG) OUT8 8 Common (--- ) DM2 + Altronix VR6 is mounted under PDS8 A HID VertX® Module - 4 - BAT + A HID VertX® Module A HID VertX® Module A HID VertX® Module Fig. 3a Pem Spacer Pan Head Screw HID VertX® Backplane Access Controller Trove HID VertX (Fuse) Kits Installation Guide T3VK75F20: Installation Instructions for HID VertX® Access Controllers 1. Fasten spacers (provided) onto metal pems configuration (A) of backplane (Fig. 4, pg. 5). 2. Mount HID VertX® modules to spacers utilizing 7/8" pan head screws (provided) (Fig. 4a, pg. 5). 3. Fasten backplane to Trove3 enclosure utilizing hardware (provided). HID VertX® Access Controller Position Chart for the Following Models: Sub-Assembly Pem Mounting V100, V200, V300, V1000, V2000 A Fig. 4 Altronix - eFlow104NB RSB2 L G N --- DC + --- BAT + Altronix - eFlow102NB L G N INTERFACE NO C NC +INP- T + RET- TRIGGER INPUT IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 F1 F2 F3 F4 F5 F6 F7 F8 FACP TRG ON ON 1234 1234 FACP MAIN 10A 250V -+-+ Power Control NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 Altronix - ACM8 INTERFACE NO C NC +INP- T + RET- TRIGGER INPUT IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 F1 F2 F3 F4 F5 F6 F7 F8 FACP TRG ON ON 1234 1234 FACP MAIN 10A 250V -+-+ Power Control NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 Altronix - ACM8 BAT + DC + A HID VertX® Module A HID VertX® Module A HID VertX® Module A HID VertX® Module A HID VertX® Module A HID VertX® Module A HID VertX® Module A HID VertX® Module NO C NC FACP +INP- T +RETINTERFACE -- + -- + POWER CONTROL INPUT PN LED TRG R1 D1 MAIN NC C NO COM NC C NO COM NC C NO COM NC C NO COM TRIGGER INPUT IN GND IN GND IN GND IN GND 1 2 3 4 LED1 LED2 LED3 LED4 OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 Altronix - ACM4 Altronix - PD8UL 1 23 4 P 567 8 FUSED POWER OUTPUTS N COMMON POWER OUTPUTS A HID VertX® Module Trove HID VertX (Fuse) Kits Installation Guide A HID VertX® Module Fig. 7a Pem Spacer HID VertX® Pan Head Access Controller Screw Backplane - 5 - T1VK3F4 (Trove1) Enclosure Dimensions (H x W x D approximate): 18" x 14.5" x 4.625" (457mm x 368mm x 118mm) 14.5" (321.3mm) 7.25" (184.2mm) 1.45" (36.8mm) 1.95" (49.5mm) 1.5" (38.1mm) 4.5" (114.3mm) 1.25" (31.8mm) 0.57" (14.5mm) 0.6" (15.2mm) 13.0" (330.2mm) 1.25" (31.8mm) 1.5" (38.1mm) 8.5" (215.9mm) 8.5" (215.9mm) 18.0" (457.2mm) 6.5" (165.1mm) 6.5" (165.1mm) 0.6" (15.2mm) 1.1" (27.9mm) 4.5" (114.3mm) 4.5" (114.3mm) 2.75" (69.9mm) 1.115" (28.3mm) 1.36" (34.5mm) 1.25" (31.8mm) - 6 - Trove HID VertX (Fuse) Kits Installation Guide T2VK7F8 (Trove2) Enclosure Dimensions (H x W x D approximate): 27.25" x 21.75" x 6.5" (692.15mm x 546.1mm x 165.1mm) 2.00" (50.8mm) 21.50" (546.1mm) 5.25" (133.35mm) 3.5"(88.9mm) 3.5"(88.9mm) 5.25" (133.35mm) 2.00" (50.8mm) 6.25" (158.8mm) 1.25" (31.8mm) 6.25" (158.8mm) 1.25" (31.8mm) 1.5" (38.1mm) 0.5625" (14.3mm) 0.685" (17.4mm) 1.77" (45mm) Knockouts 1.125" (28.3mm) 2.415" (61.3mm) 0.885" (22.5mm) 19.80" (502.9mm) 2.00" (50.8mm) 6.75" (171.5mm) 8.25" (209.5mm) 27" (685.8mm) 8.00" (203.2mm) 1.00" (25.4mm) 0.85" (21.6mm) 1.25" (31.8mm) 2.00" (50.8mm) 2.00" (50.8mm) 5.25" (133.4mm) 7.00" (177.8mm) 5.25" (133.4mm) 1.25" (31.8mm) 2.00" (50.8mm) Trove HID VertX (Fuse) Kits Installation Guide - 7 - 2.00" (50.8mm) T3VK75F20 (Trove3) Enclosure Dimensions (H x W x D approximate): 36.12" x 30.125" x 7.06" (917.5mm x 768.1mm x 179.3mm) 2.00" (50.8mm) 7.12" (222.3mm) 9.5" (241.3mm) 9.5" (241.3mm) 1.25" (31.8mm) 1.78" (45.2mm) 1.55" (39.4mm) 1.25" (31.8mm) 1.07" (27.2mm) 30.12" (768.1mm) 14.01" (355.9mm) 14.01" (355.9mm) 2" (50.8mm) 1.10" (27.9mm) G G 10.75" (273.1mm) 10.75" (273.1mm) 10.62" (269.8mm) 36.12" (917.5mm) 33.63" (854.2mm) 10.62" (269.8mm) 10.75" (273.1mm) 10.75" (273.1mm) 1.25" (31.8mm) 2" 8.75" (222.3mm) (50.8mm) 8.62" (219mm) 8.75" (222.3mm) 7.06" (179.3mm) 1.25" (31.8mm) Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 web site: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty IITrove HID VertX Kits J21U MEMBER - 8 - Trove HID VertX (Fuse) Kits Installation Guide