RG-NIS-PA Series Power Modules

Hardware Installation and Reference Guide

Document Version: V1.0

Date: 2023-11-08

Copyright © 2023 Ruijie Networks

Copyright

Copyright © 2023 Ruijie Networks

All rights are reserved in this document and this statement.

Without the prior written consent of Ruijie Networks, any organization or individual shall not reproduce, extract, back up, modify, or propagate the content of this document in any manner or in any form, or translate it into other languages or use some or all parts of the document for commercial purposes.

Ruijie and Ruijie Reyee logos are trademarks of Ruijie Networks.

All other trademarks or registered trademarks mentioned in this document are owned by their respective owners.

Disclaimer

The products, services, or features you purchase are subject to commercial contracts and terms, and some or all of the products, services, or features described in this document may not be available for you to purchase or use. Except for the agreement in the contract, Ruijie Networks makes no explicit or implicit statements or warranties with respect to the content of this document.

The content of this document will be updated from time to time due to product version upgrades or other reasons, Ruijie Networks reserves the right to modify the content of the document without any notice or prompt.

This manual is designed merely as a user guide. Ruijie Networks has tried its best to ensure the accuracy and reliability of the content when compiling this manual, but it does not guarantee that the content of the manual is completely free of errors or omissions, and all the information in this manual does not constitute any explicit or implicit warranties.

Preface

Intended Audience

Technical Support

Conventions

1. Signs

This document also uses signs to indicate some important points during the operation. The meanings of these signs are as follows:

❗ Danger

An alert that calls attention to safety operation instructions that if not understood or followed when operating the device can result in physical injury.

⚠️ Warning

An alert that calls attention to important rules and information that if not understood or followed can result in data loss or equipment damage.

⚠️ Caution

An alert that calls attention to essential information that if not understood or followed can result in function failure or performance degradation.

ℹ️ Note

An alert that contains additional or supplementary information that if not understood or followed will not lead to serious consequences.

✔️ Specification

An alert that contains a description of product or version support.

2. Note

This manual provides the device installation steps, hardware troubleshooting, module technical specifications, and specifications and usage guidelines for cables and connectors. It is intended for the users who have some experience in installing and maintaining network hardware. At the same time, it is assumed that the users are already familiar with the related terms and concepts.

1 Product Introduction

1.1 Power Modules

1.1.1 RG-NIS-PA240-48

1. Appearance

Image shows the RG-NIS-PA240-48 power module. It is a compact, rectangular unit with a blue chassis. Labels indicate 'DC ON', '+V ADJ', and input/output specifications like 'IN:100-240V~ 3A 50/60Hz' and 'OUT:48V-5A'. It features a three-pin power connector at the bottom and a DC OK relay contact.

2. External Ports

3. LEDs

LED Silkscreen Label Status Description
Output status LED DC ON Off The power supply is off.
Solid green The power supply is on.

4. Technical Specifications

Module Model RG-NIS-PA240-48
Rated Voltage Range 100–240 V, 50/60 Hz
Max. Voltage Range 85–264 V, 47–63 Hz
Max. Output Power 240 W
Ground-Leakage Current ≤ 0.5 mA
Operating Temperature -40°C to +70°C (-40°F to +158°F)
Storage Temperature -40°C to +85°C (-40°F to +185°F)
Storage Humidity Maximum: 95% RH (non-condensing)
Operating Humidity Maximum: 90% RH (non-condensing)
Weight 0.65 kg (1.43 lbs.)
Power Cord Specification 10 A power cord
Item Working Conditions Value
Output power derating Operating temperature derating -40°C to -25°C (-40°F to −13°F) 3.34%/°C
45°C to 70°C (113°F to 158°F) 115 V AC input 2.0%/°C
60°C to 70°C (140°F to 158°F) 230 V AC input 2.5%/°C
Input voltage derating 85 V AC to 100 V AC 0.67%/V AC
Short circuit protection After the short circuit is eliminated, the power supply is restored within 10s. Hiccup mode: Maintain constant current for 1s and power off for 10s to provide long-term short circuit protection and self-recovery.
Overcurrent protection 230 V AC, rated load Ordinary temperature, high temperature 110%–200% Io, self-recovery
Overvoltage protection 48 V Low temperature ≥ 105% Io, self-recovery
≤ 60 V (hiccup, self-recovery after an exception is eliminated)
Overtemperature protection 230 V AC, 70% load 80°C (176°F)

⚠️ Caution

If it is used on the RG-SWITCH, the temperature and power consumption parameters depend on the power module specifications of the RG-SWITCH.

⚠️ Warning

Operation of this equipment in a residential environment could cause radio interference. The power supply is not user-serviceable. To prevent electric shock, do not open the device.

❗ Danger

  • When the power module is powered on, its surface temperature is high. Do not touch the surface to avoid injury.
  • No flammable or combustible items are allowed at the bottom of the power module.

1.1.2 RG-NIS-PA120-48

1. Appearance

Image shows the RG-NIS-PA120-48 power module. It is similar in design to the RG-NIS-PA240-48, with a blue chassis and labels for 'DC ON', '+V ADJ', and input/output specifications like 'IN:100-240V~ 1.5A 50/60Hz' and 'OUT:48V-2.5A'. It also has a three-pin power connector and a DC OK relay contact.

2. External Ports

3. LEDs

LED Silkscreen Label Status Description
Output status LED DC ON Off The power supply is off.
Solid green The power supply is on.

4. Technical Specifications

Module Model RG-NIS-PA120-48
Rated Voltage Range 100–240 V, 50/60 Hz
Max. Voltage Range 85–264 V, 47–63 Hz
Max. Output Power 120 W
Ground-Leakage Current ≤ 1 mA
Operating Temperature -40°C to +70°C (-40°F to +158°F)
Storage Temperature -40°C to +85°C (-40°F to +185°F)
Storage Humidity 20% RH to 95% RH (non-condensing)
Operating Humidity Maximum: 90% RH (non-condensing)
Weight 0.49 kg (1.08 lbs.)
Power Cord Specification 10 A power cord
Item Working Conditions Value
Output power derating Operating temperature derating -40°C to -25°C (-40°F to −13°F) 3.34%/°C
55°C to 70°C (131°F to 158°F) 85 V AC to 164 V AC input 2.0%/°C
60°C to 70°C (140°F to 158°F) 165 V AC to 264 V AC input 2.5%/°C
Input voltage derating 85 V AC to 100 V AC 0.67%/V AC
Short circuit protection After the short circuit is eliminated, the power supply is restored within 10s. Hiccup mode: Maintain constant current for 1s and power off for 10s to provide long-term short circuit protection and self-recovery.
Overcurrent protection 230 V AC, rated load Ordinary temperature, high temperature 105%–200% Io, self-recovery
Low temperature ≥ 105%, full load after derating, self-recovery
Overvoltage protection 48 V ≤ 60 V (hiccup, self-recovery after an exception is eliminated)
Overtemperature protection 230 V AC, 70% load Start of overtemperature protection 90°C (194°F)
End of overtemperature protection Lowest: 60°C (140°F)

⚠️ Caution

If it is used on the RG-SWITCH, the temperature and power consumption parameters depend on the power module specifications of the RG-SWITCH.

⚠️ Warning

Operation of this equipment in a residential environment could cause radio interference. The power supply is not user-serviceable. To prevent electric shock, do not open the device.

❗ Danger

  • When the power module is powered on, its surface temperature is high. Do not touch the surface to avoid injury.
  • No flammable or combustible items are allowed at the bottom of the power module.

2 Preparation before Installation

2.1 Safety Suggestions

To avoid personal injury and device damage, carefully read the safety suggestions before you install the RG-NIS-PA series.

The following safety suggestions may not cover all possible dangers.

2.1.1 General Safety Precautions

2.1.2 Movement

2.1.3 Electricity

Any nonstandard and inaccurate electric operation may cause an accident such as fire or electrical shock, thus causing severe even fatal damages to human bodies and the device.

Direct or indirect touch through a wet object on high-voltage and mains supply may bring a fatal danger.

If a power supply system is equipped with a leakage protector (leakage current switch or breaker), the rated leakage action current of each leakage protector is twice greater than the maximum leakage current of all the power supplies in the system. For example, if a system is equipped with 16 identical power supplies, the leakage current of each power supply is equal to or less than 3.5 mA, and the total leakage current of the system is 56 mA. A leakage protector with 30 mA rated action current supports less than ten power supplies (that is, action current of the leakage protector/2/maximum leakage current of each power supply = 30/2/3.5 ≈ 4.28). In other words, the leakage protector with 30 mA rated action current supports no more than 4 power supplies. In this case, the 16 power supplies in the system require at least 4 leakage protectors with 30 mA rated action current and each leakage protector supports 4 power supplies. If power supplies in a system differ in models, the rated leakage action current of each leakage protector divided by two is greater than the sum of maximum leakage current of all the power supplies. The rated leakage non-action current of a leakage protector must be 50% of the leakage action current. The leakage protector with 30 mA rated leakage action current is used as an example. The rated leakage non-action current must be 15 mA. When the leakage current falls below 15 mA, the protector should not act. Otherwise, misoperation may easily occur due to high sensitivity and thus the leakage protector trips, devices are powered off, and services are interrupted.

To guarantee personal safety, the rated leakage action current of each leakage protector in the system must be equal to or less than 30 mA (human body safety current is 30 mA). When twice of the total leakage current of the system is greater than 30 mA, the system must be equipped with two or more leakage protectors.

For details of the leakage current value of each power supply model, see Chapter 0.

2.1.4 ESD

To prevent Electronic Static Discharge (ESD), pay attention to the following points:

2.2 Installation Site Requirements

To ensure the normal running and prolonged service life of the device, the installation site must meet the following requirements.

2.2.1 Load Bearing Requirements

Evaluate the load bearing requirements for the ground according to the weight of the switch and its accessories (such as the cabinet, chassis, line cards and power supply modules). Make sure the installation site meet the requirements.

2.2.2 Space Requirements

2.2.3 Anti-interference Requirements

The switch is susceptible to external interference by capacitive coupling, inductive coupling, electromagnetic waves, common impedance (grounding) coupling, or conduction over conducting wires including power cords, signal cables, and output cables. Note that:

2.2.4 Cleanness

Dust poses a severe threat to the running of the device. The indoor dust falling on the device may be absorbed by the static electricity, causing bad contact of the metallic joint. Such electrostatic absorption may occur more easily when the relative humidity is low. This affects the device lifecycle and causes communication faults. Table 2-2 lists the requirements for the dust content and granularity in the equipment room.

Table 2-2 Requirements for the Dust Content and Granularity in the Equipment Room

Dust Unit Density
Diameter ≥ 0.5 µm Particles/m3 ≤ 3.5 x 106
Diameter ≥ 5 µm Particles/m3 ≤ 3 x 104

Apart from dust, the salt, acid, and sulfide in the air in the equipment room must also meet strict requirements. This is because such poisonous substances may accelerate the corrosion of the metal and the aging of some parts. The equipment room should be protected from the intrusion of harmful gases such as sulfur dioxide, sulfured hydrogen, nitrogen dioxide, and chlorine. Table 2-3 lists the requirements.

Table 2-3 Requirements for Harmful Gases in the Equipment Room

Gas Average (mg/m3) Maximum (mg/m3)
SO2 0.3 1.0
H2S 0.1 0.5
NO2 0.5 1.0
Cl2 0.1 0.3

ℹ️ Note

The average and maximum values are measured for a week. The switch cannot be placed in the environment with the maximum density for over 30 minutes every day.

2.2.5 Grounding

A good grounding system is the basis for stable and reliable operation of the device, preventing lightning strokes and resisting interference. Carefully check the grounding conditions at the installation site according to the grounding requirements, and perform grounding operations properly as required.

⚠️ Caution

Effective grounding of the switch guarantees lightning protection and interference resistance. Therefore, connect the grounding line of the switch properly.

Safety Grounding

The device using AC power supply must be grounded by using the yellow/green safety grounding cable. Otherwise, when the insulating resistance decreases the power supply and the enclosure in the equipment, electric shock may occur.

Lightning Grounding

The surge protection system of a facility is an independent system that consists of the lightning rod, down conductor, and connector to the grounding system, which usually shares the power reference ground and ground cable. The lightning discharge ground is targeted for the facility.

EMC Grounding

The grounding required for EMC design includes the shielding ground, filter ground, noise and interference suppression, and level reference. All the above constitute the comprehensive grounding requirements. The resistance of earth wires should be less than 1 Ω. The RG-NIS-PA series switch back plane is reserved with one grounding pole, as shown below.

2.2.6 EMI

Electro-Magnetic Interference (EMI), from either outside or inside the device or application system, affects the system in the conductive ways such as capacitive coupling, inductive coupling, and electromagnetic radiation. There are two types of electromagnetic interference: radiated interference and conducted interference, depending on the type of the transmission path.

When the energy, often RF energy, from a component arrives at a sensitive component through the space, the energy is known as radiated interference. The interference source can be either a part of the interfered system or a completely electrically isolated unit. Conducted interference results from an electromagnetic wire or signal cable connection between the source and the sensitive component, along which cable the interference conducts from one unit to another. Conducted interference often affects the power supply of the device, but can be controlled by a filter. Radiated interference may affect any signal path in the device and is difficult to shield.

2.2.7 Lightning Resistance

When the AC power cable is imported outdoors and directly connected to the power port of the RG-NIS-PA series switch, use the lightning line bank to prevent the switch from being hit by lightning shocks. In this case, connect the mains supply AC cable to the lightning line bank, and connect the switch to the lightning line bank. This helps prevent the current of high-voltage lightning from passing the switch directly through the mains supply cable to a certain extent.

ℹ️ Note

The lightning line banks are not provided and should be purchased by customers as required.

2.3 Installation Tools

Common Tools Special Tools Meters
Phillips screwdriver, flathead screwdriver, related electric cables and optical cables, bolts, diagonal pliers, and straps Anti-static tools Multimeter

ℹ️ Note

The tool kit is customer-supplied.

3 Product Installation

Ensure that you have read chapter 2 carefully. Verify that the requirements described in chapter 2 have been met.

3.1 Confirmations Before Installation

Before installation, confirm the following points at the installation site:

3.2 Grounding the Power

The Power Module has a grounding stud on the rear panel. Connect the grounding stud to the grounding point of the rack and then connect the grounding point of the rack to the ground bar of the equipment room.

Precautions

ℹ️ Note

  • To avoid personal injury and device damage, connect the switch to earth ground properly. The resistance between the chassis and ground should be less than 1 ohm.
  • The O&M personnel should check whether the AC outlet is reliably connected to the protective ground of the building. If not, the O&M personnel should use a protective grounding wire to connect the AC outlet protective earth terminal to the building protective ground.
  • The power outlet should be installed near the device and easily accessible.
  • During device installation, connect the grounding wire first and disconnect it last.
  • The cross-sectional area of the protective grounding wire must be at least 2.5 mm² (12 AWG).

3.3 Installing the Power Module

The power module only supports DIN rail mounting. The installation procedure is as follows:

  1. Snap the top part of the DIN rail clamp on the DIN rail, pull the blade spring down, and then push the module inward until it is completely seated on the rail.

Diagram illustrates the connection of a power module (RG-NIS-PA120-48 or RG-NIS-PA240-48) to a network switch. The power module is shown with its AC input and DC output connected to the switch.

3.4 Bundling the Cables

Precautions

Bundling Steps

  1. Bundle the drooping part of the fiber-optic cables and twisted pair cables, and route them to both sides of the chassis for convenience.
  2. On both sides of the chassis, fasten the fiber-optic cables and twisted pair cables to the cable management bracket or trough.
  3. For the power cords, bundle them closely along the bottom of the chassis, in a straight line wherever possible.

3.5 Verifying Installation

❗ Danger

Turn off the power to avoid personal injury and damage to components caused by incorrect connection.

PDF preview unavailable. Download the PDF instead.

RG-NIS-PA Series Pow Microsoft Word 2013 Microsoft Word 2013

Related Documents

Preview Ruijie RG-ES200 Series Layer 2 Cloud Managed Switches | CCTV & SMB Networking
Explore the Ruijie RG-ES200 Series of Layer 2 Cloud Managed Switches, offering unique value for CCTV networks and SMBs. Features include IP camera recognition, loop prevention, and cloud management.
Preview Ruijie Reyee Series Access Points Web-Based Configuration Guide
Comprehensive guide to configuring Ruijie Reyee Series Access Points using the eWeb web-based management system. Covers setup, network configuration, wireless settings, and system management for network administrators and engineers.
Preview Ruijie RG-CS86 Series Multi-GE Switches Hardware Installation and Reference Guide
This guide provides comprehensive hardware installation and reference information for the Ruijie RG-CS86 Series Multi-GE Switches. It covers product overview, specifications, appearance, installation procedures, system debugging, monitoring, maintenance, troubleshooting, and appendices with details on connectors, lightning protection, cabling, and site selection.
Preview Ruijie Reyee RG-EG Series Routers Web-based Configuration Guide
Comprehensive guide to configuring Ruijie Reyee RG-EG Series Routers, powered by ReyeeOS 2.260. This document is designed for network engineers, technical support, and administrators, covering essential setup, network planning, AP management, and advanced features.
Preview Ruijie RG-RAP2266 Reyee Wi-Fi 6 AX3000 Indoor Ceiling-Mount Access Point Datasheet
Technical datasheet for the Ruijie RG-RAP2266 Reyee Wi-Fi 6 AX3000 Indoor Ceiling-Mount Access Point, detailing its features, specifications, hardware, and environmental parameters.
Preview Ruijie RG-RAP2200 Access Point User Manual
This document provides a comprehensive user manual for the Ruijie RG-RAP2200 Access Point, covering installation, configuration, and operation in multiple languages.
Preview Ruijie RG-ES200 Series 2.5G Cloud Managed PoE Switches Datasheet
Datasheet for Ruijie Reyee RG-ES200 Series 2.5G Cloud Managed PoE Switches, featuring 1x 10G Uplink, multiple PoE Out ports, and lifetime cloud management. Includes detailed specifications for RG-ES206MG-P and RG-ES209MG-P models.
Preview Ruijie Reyee RG-EG Series Routers ReyeeOS 1.216 Release Notes
This document provides release notes for ReyeeOS version 1.216 for the Ruijie Reyee RG-EG Series Routers. It includes version information, new features, resolved issues, supported platforms, and software upgrading procedures.