Instruction Manual for RAB models including: X17 XFU, 3-Way Adjustable Dusk to Dawn LED Flood Light, Dusk to Dawn LED Flood Light, Dawn LED Flood Light, LED Flood Light, X17 XFU, Flood Light

INSTRUCTIONS

Download PDF Instruction Manual

RAB X17XFU60T 30W LED Floodlight, 3891 Lumens, 120-277V, 3000K, 4000K and 5000K Color Temperature, 80 CRI, Bronze

Installation Instructions

RAB X17 Wire Guard for 35W/60W/80W LED Flood Light – COMMUNITY LIGHTING & ELECTRIC SUPPLY


File Info : application/pdf, 2 Pages, 386.19KB

PDF preview unavailable. Download the PDF instead.

x17xfu60 3way selectable flood light instructions
INSTRUCTIONS
X17TM XFU 3-WAY FIELD-ADJUSTABLE FLOODLIGHT INSTALLATION
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We'd love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com

X17 XFU 60/50/30W Knuckle

X17 XFU 60/50/30W Trunnion

X17 XFU 60/50/30W Slipfitter

IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside. WARNING: Do not use an electric generator to test LED fixtures. WARNING: Min 75°C SUPPLY CONDUCTORS.

KNUCKLE MOUNT
To ensure weatherproof seal, apply weatherproof silicone sealant around the edge of the junction box (not supplied). This is especially important with an uneven wall surface.
1. Secure the fixture to a 1/2" NPS hole in the junction box or landscape post as shown in Fig. 1. Seal arm thread using Teflon® tape or silicone sealant.
2. Make appropriate wire connections per NEC in an approved enclosure (not included) see Fig. 7.
3. The Knuckle Arm allows 180° of vertical aiming adjustment depending on the mounting position as shown in Fig. 2.

Pole

Fig: 1

Knuckle Arm Fig: 2

TRUNNION MOUNT
To adjust the angle of the Fixture using the Trunnion (Fig. 4):
1. Loosen the Pivot Bolts and Angle Locking Screws. 2. Make appropriate wire connections per NEC in an approved
enclosure (not included) see Fig. 7. 3. Adjust fixture to desired angle. 4. Tighten Pivot Bolts and Angle Locking Screw.

SLIPFITTER MOUNT
1. Place the Slipfitter over the Tenon and secure the Fixture with the Locking Bolts (4) on the side of the Slipfitter as shown in Fig. 3.
2. Make appropriate wire connections per NEC in an approved enclosure (not included) see Fig. 7.
3. Loosen the Locking Bolts (4) and swivel Fixture to desired angle.
4. Tighten the Locking Bolts (4).

Fixture
Slipfitter Mount Fig: 3
Wire

Locking Bolt (4) Tennon

Fig: 4
Angle Locking Screw Pivot Bolt

INSTRUCTIONS
X17TM XFU 3-WAY FIELD-ADJUSTABLE FLOODLIGHT INSTALLATION
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We'd love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com

FIELD ADJUSTMENT
Follow instructions below to change fixture Power (W) or Color Temperature (CCT) from the factory settings and Photocell On/Off option.
Factory Settings: 4000K and 60W
1. Remove Selector Switch Caps by turning counterclockwise using a flat head screwdriver (Fig. 5).
2. Locate the Selector Switches on the fixture (Fig. 6).
3. Select Power (W) and Color Temperature (CCT) by sliding the respective switch to the desired value.
4. Select Photocell On/Off option by sliding respective switch to the desired value.
5. Replace Selector Switch Caps and tighten with a flat head screwdriver.

0-10V DIMMABLE WIRING
Universal voltage driver permits operation at 120V thru 277V, 50 or 60 Hz. For 0-10 Dimming, follow the wiring directions as shown in Fig. 7.
1. Connect the black/brown fixture lead to the LINE supply lead.
2. Connect the white/blue fixture lead to the COMMON supply lead.
3. Connect the green/yellow wire from fixture to supply ground. Do NOT connect the GROUND of the dimming fixture to the output.
4. Connect the purple fixture lead to the DIM V+ lead.
5. Connect the pink/gray fixture lead to the DIM V- lead.
6. Cap the yellow fixture lead, if present. Do NOT connect.

Fig: 5

Selector Switch Caps

5K 4K 3K
3 2 1
Fig: 6

Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.

Fig: 7

LINE COMMON (+) DIM V+ (-) DIM V-

BLACK/BROWN WHITE/BLUE PURPLE PINK/GRAY

GROUND

GREEN/YELLOW

CLEANING & MAINTENANCE
CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized. 1. Clean glass lens with non-abrasive glass cleaning solution. 2. Do not open the fixture to clean the LED. Do not touch the LED.

TROUBLESHOOTING
1. Is the fixture grounded properly?
2. It is recommended that gloves be worn to avoid injury during installation.
3. If any smoke or spark, please turn off the power immediately.

© 2021 RAB LIGHTING Inc.
X17 XFU 60-50-30 IN-1021 P-100056

Easy Answers
rablighting.com Visit our website for product info

Tech Help Line Call our experts: 888 722-1000

e-mail Answered promptly - sales@rablighting.com

Free Lighting Layouts Answered online or by request



References

Adobe PDF Library 15.0 Adobe InDesign 16.0 (Windows)