KEMOVE T63 Three Mode Function Instructions
Important Reminder: Paperless Manuals
Kemove advocates for environmental protection and energy saving. For Kemove series products released globally, paper manuals are no longer provided. Users can download the latest manuals from the official website at www.kemove.com or find them in the upper right corner of the Kemove control hub homepage.
FCC Compliance Information
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC Warning: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirements. The device can be used in portable exposure conditions without restriction.
KEMOVE T63 Three Mode Function Instructions
The KEMOVE T63 keyboard supports three connection modes: Wired, 2.4G, and Bluetooth.
2.4G Mode
To activate 2.4G mode, press FN+B
. Hold the B
key for 3 seconds; the white light will flash, indicating pairing mode. The B
key will return to its default state upon successful connection.
Bluetooth Mode
The keyboard supports three Bluetooth profiles (BT1, BT2, BT3).
- BT1: Press and hold
FN+Z
for 3 seconds. The red and blue lights will flash alternately, indicating Bluetooth pairing mode. If the device has been paired previously, a single tap will reconnect. - BT2: Press and hold
FN+X
for 3 seconds. Follow the same pairing and reconnection procedure as BT1. - BT3: Press and hold
FN+C
for 3 seconds. Follow the same pairing and reconnection procedure as BT1.
Switching Instructions / Reminder
The ON/OFF switch located on the back of the keyboard controls the wired/wireless (battery) mode. Wireless modes cannot be used when the keyboard is in wired mode.
In wireless mode, Bluetooth and 2.4G connections can be switched directly using combination keys. When the FN
key is pressed, the B
key will light up white to indicate that the keyboard is connected and using 2.4G. Pressing FN+B
allows switching from Bluetooth mode to 2.4G mode or pairing mode.
For 2.4G mode, pairing must be initiated before inserting the receiver. This also applies after resetting the device.
In Bluetooth mode, pressing FN+Z
, FN+X
, or FN+C
will cause one of these keys to flash blue, indicating the currently active Bluetooth channel. These key combinations allow for direct switching between paired Bluetooth devices.
Power Display
In wired mode: Press FN+Right Shift
to check the charging status. The indicator will show if it is charging or fully charged.
In Bluetooth mode: Press FN+Right Shift
to view the battery level, indicated by color or percentage ranges:
- 0% - 20%
- 20% - 50%
- 50% - 95%
- 95% - 100%
FN Combined Function Keys
The keyboard features numerous FN key combinations for enhanced functionality:
Key Combination | Function |
---|---|
FN+A | |
FN+S | K |
FN+D | |
FN+F | |
FN+G | |
FN+H | + |
FN+1 | F1 |
FN+2 | F2 |
FN+3 | F3 |
FN+4 | F4 |
FN+5 | F5 |
FN+6 | F6 |
FN+7 | F7 |
FN+8 | F8 |
FN+9 | F9 |
FN+0 | F10 |
FN+- | F11 |
FN+= | F12 |
FN+U | Print Screen |
FN+I | Scroll Lock |
FN+O | Pause |
FN+J | Insert |
FN+K | Home |
FN+L | Page Up |
FN+M | Delete |
FN+,< | End |
FN+.> | Page Down |
FN+Tab | Restore the keyboard to factory settings (Press for 5 seconds) |
FN+Space | FN key function lock |
FN+Win | Win key lock / unlock |
FN+N | Switch between six-key rollover and N-key rollover (NKRO) |
FN+Enter | Enter power saving mode |
FN+T | Switch back to Standard layer (Cannot set macro commands) |
FN+Capslock | Switch the color of the default lighting effect of the keyboard |
FN+Backspace | Turn off backlight, turn on backlight, turn off all lights |
FN+Q | Profile 1 |
FN+W | Profile 2 |
FN+E | Profile 3 |
FN+R | Profile 4 |
FN+? / | Up Arrow |
FN+R_Alt | Right Arrow |
FN+R_Ctrl | Down Arrow |
FN+Menu | Left Arrow |