User Guide for VARI-LITE models including: 74817-050, 74817-150, 74817-TBD, 74817-051, 74817-151, VL3600 LT 6 Color LED Moving Head Profile Light, VL3600 LT, 6 Color LED Moving Head Profile Light, Moving Head Profile Light, Head Profile Light, Profile Light
Downloadbereich
File Info : application/pdf, 9 Pages, 2.62MB
DocumentDocumentQuick Start Guide REV A 07/22/24 VL3600 LT PROFILE IP OVerVieW This document provides basic setup instructions and safety warnings for the following product(s): VL3600 Lt VL3600 Lt VL3600 Lt VL3600 VL3600 74817-050 74817-150 74817-TBD 74817-051 74817-151 VL3600 Lt-touring Black VL3600 Lt-touring White VL3600 Lt-Flight case insert VL3600 Lt-install Black VL3600 Lt-install White INCLUDED ITEMS iNStaLLatiON aNd SetuP CONNECTING POWER This fixture requires standard AC power distribution from 120-240VAC, 50/60 Hz. Current required depends on the AC supply voltage and product model. NOTE: The mating True1 IP 65 compatible connector is supplied; however, you will need to purchase or construct a cable appropriate for your application. Depending on the application, the luminaire's AC input cable may require a different connector. If required, install a new connector meeting your requirements using the following wire color code reference: WIRE* CONNECTION Green/yellow ac ground Blue ac neutral Brown ac line * international (Harmonized) Standard WARNING: DO NOT connect to three-phase service in countries with 240V power. Single-phase power from 120-240V RMS: CONNECTION PIN X G ac neutral X ac line Y Y Ground (earth) G Two-phase power at 208V RMS: CONNECTION PIN Phase 1 X Phase 2 Y Ground (earth) G 1 Quick Start Guide REV A 07/22/24 VL3600 LT PROFILE IP CURRENT VERSUS VOLTAGE TABLE 1 provides the luminaire's current draw at specific voltages. Total luminaire current is calculated with the lamp on and all motors sequencing. CONNECTING DATA A maximum of 32 luminaires may be connected in any one DMX data link. NOTE: This maximum limit applies to the luminaire "daisy chain" only. Your system or console may require fewer luminaires on a single data link path. Consult your console documentation for more information. TABLE 1. CURRENT VS. VOLTAGE (1000W LED) AC VOLTAGE AT 60HZ 120V 180V 208V 230V 240V 264V 277V TOTAL LUMINAIRE CURRENT 12.66a 8.22a 7.12a 6.32a 6.12a 5.58a 5.38a TOTAL LUMINAIRE POWER 1505W 1475W 1472W 1460W 1445W 1440W 1435W PFC 0.996 0.988 0.987 0.987 0.983 0.980 0.966 To connect power and data: Step 1. Connect data cable from console to first luminaire in chain at DATA IN connector. Step 2. If required, connect additional data cables from DATA THRU connectors to DATA IN connectors of remaining luminaires in link. Step 3. At last luminaire in link, install male termination connector at DATA THRU connector. (Luminaires and other devices on the same DMX chain may not function properly without termination.) Termination** Data Thru Data Thru Data In Step 4. Connect AC Input Cable connector to power input source. Step 5. Dress AC input and data cables and secure them so that they will not interfere with luminaire head and yoke movement. 2 Quick Start Guide REV A 07/22/24 VL3600 LT PROFILE IP FLOOR MOUNTING All luminaires included in this manual are designed to sit directly on its base in a floor installation application. When used in this type of application, be sure to leave enough space around the luminaire to allow proper, uninterrupted airflow for cooling and movement. HANGING THE FIXTURE The VL3600 LT PROFILE IP can be hung horizontally or 45° vertically from any structure designed to work with the type of load created by this moving luminaire. Two mounting truss hooks or other mounting hardware are required. Many compatible truss hooks are available from different manufacturers for your particular needs. SYSTEM MENU LCD DISPLAY CABLES A minimum of two hooks per luminaire is required. If mounting method does not use truss hooks, two attachment points, per luminaire, are required. Install mounting hardware and brackets: Step 1. Install truss hooks on two provided truss hook brackets as required as shown. NOTE: Various types of truss hooks can be used. The Mega Claw truss hook, as well as many other standard hooks, can be ordered separately. Step 2. Step 3. Determine required configuration of bracket installation. Brackets may be installed in many different orientations as shown. While pulling up on locking mechanism release, fit keyed holes onto raised mounting buttons at bottom of enclosure. Slide forward and release locking mechanism to lock in place. Ensure brackets are locked securely. WARNING: Ensure that the bracket locking mechanism is fully seated after the bracket is installed on the fixture. 3 Quick Start Guide REV A 07/22/24 VL3600 LT PROFILE IP FIGURE 1. INSTALLING BRACKETS ON LUMINAIRE ENCLOSURE Installing in Truss: Step 1. Using two people, lift luminaire into mounting position. Step 2. Secure in place with truss hook. Ensure truss hook hardware that locks hook in place (e.g. wing bolt) is properly tightened and that luminaire is fully supported. Step 3. Attach safety cable (as required) as follows: a. Loop safety cable at least once around safety cable anchor point rod. b. Loop safety cable at least once around truss/pipe and secure around pipe. Step 4. Make sure tilt and pan locks are disengaged so luminaire moves freely. Step 5. Connect power and data cables. 4 Quick Start Guide REV A 07/22/24 VL3600 LT PROFILE IP MENU CONTROLS The menu system is controlled by an OK (Enter), MENU (Escape), and two Arrow () buttons. Press and hold the ENTER button, and then quickly press the UP, Down, UP, DOWN buttons in 2s to unlock the screen. QUICK REFERENCE MENU KEY SHORTCUTS MENU KEY SHORTCUTS Holding Menu at Power up Menu + up Menu + down Menu + enter enter + up enter + down up + down enter + up + down at Power up FUNCTION Bypass calibration recal all Pan / tilt deactivated Factory defaults Led On Led Off display FLiP reset timers Shortcut 5 Quick Start Guide REV A 07/22/24 VL3600 LT PROFILE IP Quick reFereNce dMX MaPS The short form DMX maps are available on the following pages. Visit the product page for full DMX maps. · table 2. 16-Bit Mode · table 3. 16-Bit eNHaNced Mode (deFauLt)enhanced Mode (default) TABLE 2. DMX CHANNEL PARAMETER 1 intensity High 2 intensity Low 3 Pan High 4 Pan Low 5 tilt High 6 tilt Low 7 Focus High 8 Focus Low 9 Zoom High 10 Zoom Low 11 cyan 12 Yellow 13 Magenta 14 ctO Wheel 15 color adjustment (color Wheel 2) 16 color Wheel 1 17 color Wheel 1 control 18 Gobo Wheel 1 (Fixed) 19 Gobo Wheel 1 control 20 Gobo Wheel 2 21 Gobo Wheel 2 rotate/index High Byte 22 Gobo Wheel 2 rotate/index Low Byte 23 Gobo Wheel 2 control 24 VLFX (Gobo Wheel 3) 25 VLFX (Gobo Wheel 3) rotate/index High Byte 16-BIT MODE DMX CHANNEL PARAMETER 26 VLFX (Gobo Wheel 3) rotate/index Low Byte 27 VLFX (Gobo Wheel 3) control 28 iris 29 Frame 1a 30 Frame 1B 31 Frame 2a 32 Frame 2B 33 Frame 3a 34 Frame 3B 35 Frame 4a 36 Frame 4B 37 Frame rotate 38 Prism 1 (triangular) 39 Prism 1 index/rotate High Byte 40 Prism 1 index/rotate Low Byte 41 Prism 2 (Flat) 42 Prism 2 index/rotate High Byte 43 Prism 2 index/rotate Low Byte 44 Frost 45 Strobe 46 Future use channel 47 Programmers channel 48 Fan control 49 Luminaire control 6 Quick Start Guide REV A 07/22/24 VL3600 LT PROFILE IP TABLE 3. 16-BIT ENHANCED MODE (DEFAULT) DMX PARAMETER CHANNEL 1 intensity High 2 intensity Low 3 Pan High 4 Pan Low 5 tilt High 6 tilt Low 7 Focus High 8 Focus Low 9 Zoom High 10 Zoom Low 11 cyan 12 Yellow 13 Magenta 14 ctO Wheel 15 color adjustment (color Wheel 2) 16 color Wheel 1 17 color Wheel 1 control 18 Gobo Wheel 1 (Fixed) 19 Gobo Wheel 1 control 20 Gobo Wheel 2 21 Gobo Wheel 2 rotate/index High Byte 22 Gobo Wheel 2 rotate/index Low Byte 23 Gobo Wheel 2 control 24 VLFX (Gobo Wheel 3) 25 VLFX (Gobo Wheel 3) rotate/index High Byte 26 VLFX (Gobo Wheel 3) rotate/index Low Byte 27 VLFX (Gobo Wheel 3) control DMX PARAMETER CHANNEL 28 iris 29 Frame 1a 30 Frame 1B 31 Frame 2a 32 Frame 2B 33 Frame 3a 34 Frame 3B 35 Frame 4a 36 Frame 4B 37 Frame rotate 38 Prism 1 (triangular) 39 Prism 1 index/rotate High Byte 40 Prism 1 index/rotate Low Byte 41 Prism 2 (Flat) 42 Prism 2 index/rotate High Byte 43 Prism 2 index/rotate Low Byte 44 Frost 45 Strobe 46 Future use channel 47 Programmers channel 48 Focus timing 49 Optics timing 50 color timing 51 Beam timing 52 Gobo timing 53 Fan control 54 Luminaire control 7 Quick Start Guide REV A 07/22/24 VL3600 LT PROFILE IP WARNING: It is not recommended to power any Vari-Lite fixture from a dimmer - even in 'NONDIM' mode. Dimmer and non-dim modules are not suitable sources of power because their output modifies the AC wave form. This may work for a short time, but will eventually result in power problems, operating errors, and/or fixture failure and may void the warranty. WARNING: It is the responsibility of the user to adequately protect supply source with a correct size and type circuit breaker and not overload circuits. WARNING: This unit has a battery. Replace only with the correct type of battery. Failure to use the correct battery could cause serious damage to the fixture. Dispose of used batteries appropriately. IEC/TR 62778 NOTICE ON RETINAL BLUE LIGHT HAZARD For reference only. refer to product label for specific warnings for this product. risk Group 1 None risk Group 2 cautiON! do not stare into beam. risk Group 3 WarNiNG! do not look into the beam. No direct eye exposure to the beam is permitted. 8 Quick Start Guide REV A 07/22/24 VL3600 LT PROFILE IP SAFETY WARNINGS AND NOTICES Read this user manual in full before attempting to install, operate or maintain the fixture to which it relates. This user manual is intended to provide general guidance to such suitably qualified personnel. Installation and operation of the fixture are to be performed by qualified personnel only. When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS. · For indoor, dry location use only. Do not use outdoors unless fixture each use, carefully inspect power cables and replace any damaged is suitably IP rated. cables. · Use safety tether when mounting. · Exterior surfaces of the luminaire will be hot during operation. Take · Equipment should be mounted in locations and at heights where appropriate precautions. it will not be readily subjected to tampering by unauthorized · Continuous use of the fixture may shorten the lifespan. Power down personnel. the fixture when not in use. · Not for residential use. Do not use this equipment for other than · Do not cycle power on and off repeatedly. Disconnect mains power intended use. if the fixture is not used for an extended period. · Note distance requirement(s) from combustible materials or · Clean fixtures regularly, particularly when working in a dusty illuminated objects. Do not mount near gas or electric heaters. environment. · Install only in locations with adequate ventilation. Ensure sure that · Never touch power cables or wires while the fixture is powered on. ventilation slots are not blocked. · Avoid entangling power wires with other cables. · Ensure that the voltage and frequency of the power supply match · In the event of a serious operating problem, immediately the power requirements of the fixture. discontinue using the fixture. · The fixture must be earthed/grounded to the appropriate conductor. · It is hazardous to operate luminaires without lens or shield. Shields, · Do not operate fixture outside the specified ambient temperature lenses, or ultraviolet screens shall be changed if they have become range. visibly damaged to such an extent that their effectiveness is · Do not connect the fixture to any dimmer pack. impaired, for example, by cracks or deep scratches. · The use of accessory equipment not recommended by the · Original packing materials can be reused for transporting the manufacturer may cause an unsafe condition and void warranty. fixture. · Refer service to qualified personnel. This fixture contains no user · Do not look directly at the LED light beam while the fixture is on. serviceable parts. · This is a Class A product. In a domestic environment this product · Prior to first use, carefully inspect fixture to ensure no damage has may cause radio interference, in which case, the user may be occurred during shipping. required to take adequate measures. · Materials used in the manufacturing process can cause strong odors · The light source contained in this luminaire shall only be replaced by when the product is new. These odors dissipate over time.Prior to the manufacturer or service agent or similarly qualified person. SAVE THESE INSTRUCTIONS. WARNING: Refer to National Electrical Code® and local codes for cable specifications. Failure to use proper cable can result in damage to equipment or danger to personnel. COMPLIANCE NOTICE FCC DECLARATION OF CONFORMITY This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with Vari-Lite system, service, and safety guidelines, may cause harmful interference to radio communications. As tested under this standard: FCC 47CFR 15B clA*CEI Issued:2009/10/01 Title 47 CFR Part 15 Subpart B Unintentional Radiators Class A Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his/her own expense. EU DECLARATION OF CONFORMITY We, Vari-Lite LLC., 10911 Petal Street, Dallas, Texas 75238, declare under our responsibility for the products contained herein are in conformity with the essential requirements of the following European Directives and harmonized standards: Low Voltage Director (LVD), 2006/95/EC EN 60589-2-17:1984+A1:1987+A2:1990 used in conjunction with 60598-1:2008/A11:2009 ©2024 Signify Holding. All rights reserved. All trademarks are owned by Signify Holding or their respective owners. The information provided herein is subject to change, without notice. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract, unless otherwise agreed by Signify. Data subject to change. 9 CUSTOMER SERVICE If you have any questions regarding this product, please contact Customer Service by phone at +1 214-647-7880 or by email at entertainment.service@signify.com. VL3600 Lt PrOFiLe iP Quick Start Guide VerSiON date: JuLY 22 2024