Instruction Manual for Lumineux models including: 3CCT Rutland Bulkhead, 3CCT, Rutland Bulkhead, Bulkhead
Rutland Range | Lumineux UK
Rutland 12W Instruction Manual - MAR 22
File Info : application/pdf, 2 Pages, 840.58KB
DocumentDocumentRutland 3CCT Bulkhead IP65 3CCT 101^ BESA Lm/W 12W 5 YR Warranty Rutland Bulkhead INSTALLATION INSTRUCTIONS READ THESE INSTRUCTIONS THOROUGHLY BEFORE INSTALLATION KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. IMPORTANT: This product must be installed by a qualified electrician or competent person, and in accordance with current building and IET wiring regulations. 1 on off BOX CONTENTS This lighting fixture has been properly packed to avoid damage during transit. Before commencing with the installation carefully inspect the luminaire to confirm there is no 4 damage. DO NOT INSTALL if any damage has occurred to the fixture or any of its components. · Light Fitting · Instruction Manual TOOLS REQUIRED · Drill · Screwdriver · Cable 2 3 Geartray Twist-lock 5 6 Electrical connection wiring NEUTRAL = Blue EARTH = Green/Yellow LIVE (SW) = Brown Grommet PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION. WARNING: Risk of electric shock! Isolate the mains power before proceeding. · Turn off the mains power before performing inspections, installation, or removal · Verify that the supply voltage is correct by comparing it with the luminaire label information · It is the installers responsibility to ensure installation is suitable for the total load of the luminaire(s). The supply cable, fuses/circuit brakers must be correctly rated for the electrical load and considering for any transient inrush currents that may occur · Do not perform insulation strength or resistance tests on installed luminarie(s) connected 1. Remove the diffuser by gently twisting anti-clockwise 2. Twist the locking tab to loosen and remove the geartray on 3. Drill appropriately sized holes through your chosen mounting points in the base 4. Install grommet to your chosen cable entry and pierce, off making a hole just large enough to make a tight fit around the incoming mains cable. Carefully thread cable through grommet 5. Secure the fitting in place. Note: If protection against ingress of moisture is required the heads of screws must be covered with a silicone or similar sealant 6. Wire as per diagram (5) 7. Please see overleaf for instructions on how to set all sensor versions 8. Replace the geartray and twist the locking tab to secure in place, then refit the diffuser 9. Re-connect the mains supply AF G Manby Business Park, Manby, Lincolnshire, LN11 8UT Lumineux is a B&T Associates Ltd company. ^Lm/W figures based on 4000K output. Technical Helpline: +44 (0)1507 328031 www.lumineux.co.uk Rutland 3CCT Bulkhead DISPOSAL The light source of this unit is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced. Disassembly instructions for end of life disposal available on website. Disposal of Electronic Equipment WEEE Directive 2002/96/EC This product falls within the scope of the Waste Electrical & Electronic Equipment Directive (WEEE), which means the product should not be disposed of as normal household waste. Please recycle where facilities exist or check with your Local Authority. RoHS All components and materials used in this product are RoHS 2002/95/EC compliant. Specifications may change from time to time. The information contained in this leaflet is for guidance only and should not be considered as always accurate and should be treated as not representative. WARRANTY This luminaire is warranted for a period of 5 years from the date of purchase**. The backup battery pack in the emergency version is warranted for a period of 12 months. The warranty could be invalidated should the light fitting not be installed according to these instructions, outside the scope of the specification or the product has been altered or tampered with in any way. Please see website for terms and conditions. PRODUCT TEMP SPECIFICATION Standard -20 to +40ºC Emergency 0 to +30ºC Revision 2 - March 2022 MICROWAVE SENSOR SETTINGS RUTLAND BULKHEAD DIMENSIONS Detection Range: This determines the effective range of the motion. Note that reducing the sensitivity will also narrow the detection range. Hold Time Duration: This determines the time the fitting remains at 100% illumination following motion detection. Daylight Setting: This setting holds off the 100% light output should there be sufficient daylight. STANDARD ON/OFF SENSOR DETECTION AREA 12 ON ON 100% OFF ON 75% ON OFF 50% OFF OFF 25% HOLD TIME 34 5 ON ON ON 5S OFF ON ON 30S ON OFF ON 90S OFF OFF ON 5Min ON ON OFF 20Min OFF OFF OFF 30Min DAYLIGHT 67 8 ON ON ON 2Lux ON ON OFF 10Lux OFF ON OFF 30Lux ON OFF OFF 50Lux OFF OFF OFF Disable Part No. Description Watts L (mm) W (mm) H (mm) Weight Rutland 430156 3CCT 12W 330 330 110 0.8Kg Bulkhead W H L STEP DIM DRIVER SETTINGS DETECTION AREA 1 I ON 100% II OFF 50% HOLD TIME 2 3 I ON ON 5S II ON - 30S III - ON 3min IV - - 10min DAYLIGHT SENSOR 4 5 I ON ON 5Lux II ON - 15Lux III - ON 30Lux IV - - Disable STAND-BY PERIOD 6 7 I ON ON 0s II ON - 30s III - ON 10min IV - - + STAND-BY DIM LEVEL 8 I ON 10% II _ 25% * Do not change output current unless instructed or this will void warranty. * OUTPUT CURRENT S1 S2 S3 450mA ON ON ON 400mA ON - ON 380mA - - ON 350mA - ON - 320mA ON - - 300mA - - - Installation Engineers Contact Details: Name: Tel: Luminaire Reference / Location Wiring instructions for units equipped an with EMERGENCY function Emergency lighting luminaries must be installed and maintained in accordance with the emergency lighting standard BS 5266-1 1. Connect incoming earth cable to `Earth' terminal on connector block. 2. Connect incoming neutral cable to `Neutral' terminal on connector block. 3. For the emergency unit to work correctly, please ensure that an uninterrupted permanent live feed is present and is connected directly to the `Permanent Live' terminal of the mains terminal block. Please ensure there are no switches, PIRs etc within the permanent live feed, constant switching of the emergency pack could result in premature battery failure. 4. Connect incoming switched live cable to the terminal marked "Switched Live" NOTE: If there is no switch live feed and the unit has a microwave sensor, simply bridge across from the "Permanent Live" to the Switch Live" on the mains terminal block. 5. There should be a loose flying lead connected to the battery. This needs to be attached to the flying lead from the emergency control unit. 6. Following power up the green LED indicator should illuminate to indicate charging. If power to the unit is disrupted or isolated, the unit indicating green LED will switch off, triggering the emergency LEDs to illuminate. 7. Please allow 24 hours charge before first emergency test. EMERGENCY FITTINGS ONLY. EARTH CONNECTION REQUIRED. L - LIVE (SW) = Brown - EARTH = Green/Yellow N - NEUTRAL = Blue L1 - PERMANENT LIVE (PL) = Black Luminaire Details: Full Recharge Duration 24 Hours Emergency Duration 3 Hours Lamp Type LED Self-Test EMERGENCY function Type Test Functional 1 Functional 2 Functional 3 Functional 4 Functional 5 Functional 6 Functional 7 Functional 8 Functional 9 Functional 10 Functional 11 3hr Duration 12 Year 1 Signed Date ROUTINE TEST RECORD Year 2 Year 3 Signed Date Signed Date Year 4 Signed Date Year 5 Signed Date The self-test version of emergency is fitted with control gear that will carry out periodic functional tests every 1 month and full duration test every 12 months. 1 Sec ON 1 Sec OFF 0.5 Sec ON 0.5 Sec OFF 3 Sec ON 3 Sec OFF 3 Sec ON 1 Sec OFF Fault/Test/Status Battery fully charged and operational Battery Charging Battery Failure Duration Test Failure Automatic Testing - Function 5 minute test (Every 30 days) Automatic Testing Duration test is 3 hours (every 12 months) Reason Standard daily use Initial charge / battery topping up Battery is disconnected or damaged/faulty Maintenance check required by qualified engineer Self-testing in operation Self-testing in operation This product contains a light source of energy efficiency Class F. ** Please see our website for more detailed information on warranty. Technical Helpline: +44 (0)1507 328031