Instruction Manual for Lumineux models including: 3CCT Rutland Bulkhead, 3CCT, Rutland Bulkhead, Bulkhead

Rutland 12W Instruction Manual - MAR 22

Download

Rutland Range | Lumineux UK

Rutland 12W Instruction Manual - MAR 22 ...

Rutland 12W Instruction Manual - MAR 22


File Info : application/pdf, 2 Pages, 840.58KB

PDF preview unavailable. Download the PDF instead.

Rutland 12W Instruction Manual - MAR 22
Rutland 3CCT Bulkhead

IP65 3CCT

101^

BESA

Lm/W

12W
5 YR
Warranty

Rutland

Bulkhead

INSTALLATION INSTRUCTIONS

READ THESE INSTRUCTIONS THOROUGHLY BEFORE
INSTALLATION KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE.
IMPORTANT: This product must be installed
by a qualified electrician or competent person, and in accordance with current building and IET wiring regulations.

1
on
off

BOX CONTENTS

This lighting fixture has been properly

packed to avoid damage during

transit. Before commencing with the

installation carefully inspect the luminaire to confirm there is no

4

damage. DO NOT INSTALL if any

damage has occurred to the fixture

or any of its components.

· Light Fitting · Instruction Manual

TOOLS REQUIRED

· Drill

· Screwdriver · Cable

2

3

Geartray

Twist-lock

5

6

Electrical connection wiring
NEUTRAL = Blue EARTH = Green/Yellow LIVE (SW) = Brown
Grommet

PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION.

WARNING: Risk of electric shock! Isolate the mains power before proceeding.
· Turn off the mains power before performing inspections, installation, or removal
· Verify that the supply voltage is correct by comparing it with the luminaire label information
· It is the installers responsibility to ensure installation is suitable for the total load of the luminaire(s). The supply cable, fuses/circuit brakers must be correctly rated for the electrical load and considering for any transient inrush currents that may occur
· Do not perform insulation strength or resistance tests on installed luminarie(s) connected

1. Remove the diffuser by gently twisting anti-clockwise

2. Twist the locking tab to loosen and remove the geartray

on

3. Drill appropriately sized holes through your chosen

mounting points in the base

4. Install grommet to your chosen cable entry and pierce,

off

making a hole just large enough to make a tight fit

around the incoming mains cable. Carefully thread

cable through grommet

5. Secure the fitting in place. Note: If protection against ingress of moisture is required the heads of screws must be covered with a silicone or similar sealant

6. Wire as per diagram (5)

7. Please see overleaf for instructions on how to set all sensor versions

8. Replace the geartray and twist the locking tab to secure in place, then refit the diffuser

9. Re-connect the mains supply

AF
G

Manby Business Park, Manby, Lincolnshire, LN11 8UT Lumineux is a B&T Associates Ltd company.

^Lm/W figures based on 4000K output.
Technical Helpline: +44 (0)1507 328031

www.lumineux.co.uk

Rutland 3CCT Bulkhead

DISPOSAL

The light source of this unit is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.
Disassembly instructions for end of life disposal available on website.
Disposal of Electronic Equipment WEEE Directive 2002/96/EC This product falls within the scope of the Waste Electrical & Electronic Equipment Directive (WEEE), which means the product should not be disposed of as normal household waste. Please recycle where facilities exist or check with your Local Authority. RoHS ­ All components and materials used in this product are RoHS 2002/95/EC compliant.
Specifications may change from time to time. The information contained in this leaflet is for guidance only and should not be considered as always accurate and should be treated as not representative.

WARRANTY

This luminaire is warranted for a
period of 5 years from the date of purchase**. The backup battery pack in the emergency version is warranted for a period of 12 months. The warranty could be invalidated should the light fitting not be installed according to these instructions, outside the scope of the specification or the product has been altered or tampered with in any way. Please see website for terms and conditions.

PRODUCT TEMP SPECIFICATION

Standard

-20 to +40ºC

Emergency 0 to +30ºC

Revision 2 - March 2022

MICROWAVE SENSOR SETTINGS

RUTLAND BULKHEAD DIMENSIONS

Detection Range: This determines the effective range of the motion. Note that reducing the sensitivity will also narrow the detection range.

Hold Time Duration: This determines the time the fitting remains at 100% illumination following motion detection.

Daylight Setting: This setting holds off the 100% light output should there be sufficient daylight.

STANDARD ON/OFF SENSOR

DETECTION AREA
12
ON ON 100% OFF ON 75% ON OFF 50% OFF OFF 25%

HOLD TIME
34 5
ON ON ON 5S OFF ON ON 30S ON OFF ON 90S OFF OFF ON 5Min ON ON OFF 20Min OFF OFF OFF 30Min

DAYLIGHT
67 8
ON ON ON 2Lux ON ON OFF 10Lux OFF ON OFF 30Lux ON OFF OFF 50Lux OFF OFF OFF Disable

Part No. Description Watts L (mm) W (mm) H (mm) Weight
Rutland 430156 3CCT 12W 330 330 110 0.8Kg
Bulkhead

W

H

L

STEP DIM DRIVER SETTINGS

DETECTION AREA 1
I ON 100% II OFF 50%

HOLD TIME 2 3
I ON ON 5S II ON - 30S III - ON 3min IV - - 10min

DAYLIGHT SENSOR 4 5
I ON ON 5Lux II ON - 15Lux III - ON 30Lux IV - - Disable

STAND-BY PERIOD 6 7
I ON ON 0s II ON - 30s III - ON 10min IV - - +

STAND-BY DIM LEVEL 8
I ON 10% II _ 25%

* Do not change output current unless instructed or this will void warranty.

* OUTPUT CURRENT

S1 S2 S3

450mA ON ON ON

400mA ON - ON

380mA -

- ON

350mA - ON -

320mA ON -

-

300mA -

-

-

Installation Engineers Contact Details:

Name:

Tel:

Luminaire Reference / Location

Wiring instructions for units equipped an with EMERGENCY function
Emergency lighting luminaries must be installed and maintained in accordance with the emergency lighting standard BS 5266-1
1. Connect incoming earth cable to `Earth' terminal on connector block. 2. Connect incoming neutral cable to `Neutral' terminal on connector block. 3. For the emergency unit to work correctly, please ensure that an
uninterrupted permanent live feed is present and is connected directly to the `Permanent Live' terminal of the mains terminal block. Please ensure there are no switches, PIRs etc within the permanent live feed, constant switching of the emergency pack could result in premature battery failure. 4. Connect incoming switched live cable to the terminal marked "Switched Live" NOTE: If there is no switch live feed and the unit has a microwave sensor, simply bridge across from the "Permanent Live" to the Switch Live" on the mains terminal block. 5. There should be a loose flying lead connected to the battery. This needs to be attached to the flying lead from the emergency control unit. 6. Following power up the green LED indicator should illuminate to indicate charging. If power to the unit is disrupted or isolated, the unit indicating green LED will switch off, triggering the emergency LEDs to illuminate. 7. Please allow 24 hours charge before first emergency test.
EMERGENCY FITTINGS ONLY. EARTH CONNECTION REQUIRED.
L - LIVE (SW) = Brown
- EARTH = Green/Yellow
N - NEUTRAL = Blue
L1 - PERMANENT LIVE (PL) = Black

Luminaire Details:

Full Recharge Duration 24 Hours Emergency Duration 3 Hours

Lamp Type LED

Self-Test EMERGENCY function

Type Test
Functional 1 Functional 2 Functional 3 Functional 4 Functional 5 Functional 6 Functional 7 Functional 8 Functional 9 Functional 10 Functional 11 3hr Duration 12

Year 1 Signed Date

ROUTINE TEST RECORD

Year 2

Year 3

Signed Date Signed Date

Year 4 Signed Date

Year 5 Signed Date

The self-test version of emergency is fitted with control gear that will carry out periodic functional tests every 1 month and full duration test every 12 months.

1 Sec ON 1 Sec OFF
0.5 Sec ON 0.5 Sec OFF
3 Sec ON 3 Sec OFF 3 Sec ON 1 Sec OFF

Fault/Test/Status Battery fully charged
and operational
Battery Charging
Battery Failure
Duration Test Failure
Automatic Testing - Function 5 minute test (Every 30 days)
Automatic Testing Duration test is 3 hours
(every 12 months)

Reason
Standard daily use
Initial charge / battery topping up
Battery is disconnected or damaged/faulty
Maintenance check required by qualified engineer Self-testing in operation
Self-testing in operation

This product contains a light source of energy efficiency Class F.

** Please see our website for more detailed information on warranty.

Technical Helpline: +44 (0)1507 328031



References

Adobe PDF Library 15.0 Adobe InDesign 15.1 (Macintosh)