User Manual for Temtop models including: M10 Plus, M10 Plus Air Quality Monitor, Air Quality Monitor, Quality Monitor, Monitor
Elitech Technology, Inc. M10PLUS Air Quality Monitor 2ATVW-M10PLUS 2ATVWM10PLUS m10plus
File Info : application/pdf, 17 Pages, 2.91MB
DocumentDocumentM10+ Air Quality Monitor User Manual PM2.5 (Parculate Maer 2.5) refers to fine parcles with a diameter of 2.5 microns or less. Due to its ny size, PM2.5 can get absorbed into the bloodstream and lungs, so long-term exposure to high levels of PM2.5 may cause eye and nose irritaon, coughing, asthma, emphysema, lung disease, heart aacks, cancer, and more. Carbon dioxide(CO2) is a colorless and odorless gas usually derived from the breath of humans and animals. High CO2 concentraon means that fresh air or venlaon is required; otherwise, it may cause problems such as drowsiness, dizziness, loss of aenon, and cognive impairment. TVOC (Total Volale Organic Compounds) are a wide range of chemicals that readily evaporate into the air at room temperature. TVOC sensors behave similarly to the human nose, responding to changes in the relave intensity of indoor TVOCs on a scale from 1 to 500. Temperature & Humidity may oen be ignored however they do have a significant impact on individual's well-being, comfort, health and safety as well as your property. High humidity may lead to an increase in household air pollutants especially the biological contaminants such as molds, bacteria, viruses and dust mites; cold, low humidity may cause nosebleeds, skin and respiratory irritaons, dyspnea, stac electricity and etc. AQI (Air quality index) is a quick guide to air quality levels. It aims to indicate the cleanliness or polluon level of the air in an easy-to-understand way. It ranges from 0 to 500, with higher values indicang higher levels of air polluon and adverse health effects. AQI assessments can show PM2.5, PM10, O3, SO2, NO2, CO, etc. Temtop calculates AQI according to EPA standards and focuses only on PM2.5 and PM10. 1 ® Do not expose the detector to heavily contaminated environments for long periods, as this can damage the sensor. ® Do not use the detector in wet condions for extended periods to ensure accurate measurements. ® Do not use the detector for long periods in environments with a strong, irritang smell to ensure accurate measurements. ® Do not cover the vents of the detector and keep lint out of the detector, as the parcle sensor may not work correctly. ® Do not dismantle the unit yourself. In the event of a defect, contact your dealer instead, who will liaise with the service centre and, if necessary, send the device in for repair. ® Children should only use this device under adult supervision. Keep packaging materials, such as plasc bags and plasc wrap, out of the reach of children as they present a choking hazard. ® This product is intended for monitoring the health of the indoor environment only and should not be considered a professional measurement tool. 2 Buzzer Display Status Time Temperature & Humidity Display Area Baery Level & Charging Status USB Port Power Buon Back Buon Air Quality Display Area Bluetooth Health Level Display Area Air Inlet/Outlet 3 Model: M10+ Dimensions: 82x82x31mm (3.2x3.2x1.2 in) Baery capacity: 2200mAh Input: DC 5V 1A Operaon environment: 0-50°C (32-122°F) 0-90%RH PM2.5 Measuring range: 0-999.9 g/m3 Resoluon: 0.1 g/m3 Accuracy: ±10g/m3(0-100g/m3) ±10%(100-500g/m3) CO2 Measuring range: 400-5000ppm Resoluon: 1ppm Accuracy: ±(40ppm +5%) (400-2500ppm) TVOC Index range: 1-500 Resoluon: 1 Temperature* Measuring range: 0-60°C (32-140°F) Resoluon: 0.1°C (0.1°F) Accuracy: ±0.5°C (±0.9°F) Humidity Measuring range: 0-99%RH Resoluon: 0.1%RH Accuracy: ±3%RH * When the product is charged, the temperature will have an error of ±0.5°C, and it will recover in about 10 minutes after full change. When the temperature measurement environment suddenly changes, and the temperature difference is large, it may takes 3 to 5 minutes adaptation time. Note: The above data are from Temtop Laboratory. 4 For indoor use: Keep the room/area airght for 10 minutes to obtain more accurate results. If the baery level shows , please charge the detector in me to avoid being affected during use (it can also recharge when switched off). 1. On/Off Press 2s to turn ON/OFF the M10+ monitor. 2S 5 2. Display 1. Click the Home buon to switch the parameter display interface; the display order is PM2.5/AQI/CO/TVOC. 2. Double-clicking the Power buon automacally switches the parameter display interface with an interval of 3s. Double press again to exit Auto Loop mode. PM2.5 Status Poor Fair Good Reference 55.5~999.9 12.1~55.4 0~12 Status Poor Fair Good Reference 151~500 51~150 0~50 AQI* *Follow EPA particle pollution standards to calculate the AQI for PM2.5. 6 Status Poor Fair Good Reference 1501~5000 1001~1500 400~1000 CO2 Status Poor Fair Good Reference 351~500 101~350 1~100 TVOC Buzzer switch Icon Displayed: buzzer sound on the device is turned on; Disappears: the buzzer sound is turned off. 7 3. Back Buon operate Click Double click Press and hold 3s status Turn on the bluetooth Turn on/off the buzzer Switch temperature unit (/) 4. Charging When the baery level is low, please charge it by connecng it to the USB cable and power supply. 8 5. Bluetooth Connecon 1. Temtop App Please search Temtop on App Store or Google Play, or simply scan the QR code below to download the app: 9 2. Add Device a. Click the back buon to turn on your product's bluetooth and on the home page of the Temtop app, click on the "+" sign to start adding devices. 137 31 Add Device b. Enable your phone's Bluetooth with the app, which will automacally detect Temtop devices in range of Bluetooth. Please select the Temtop device you wish to add and click the Add buon. When encountering issues connecng to the device, follow these steps to ensure a successful connecon: 1)Locate the buon on the back of the device and click it to acvate the device's Bluetooth broadcasng. 2)Bring the device close to your phone, ensuring they are in close proximity to facilitate a successful Bluetooth connecon. 10 M10+_908642791462510634 42 M10+_908642791462510634 42 Change device name Please enter a new device name M10+_Temtop 9/50 CANCEL OK 3. APP Main Funcons · Access real-me measurement data. · View historical data curves. · Data storage and export. · Calibrate the device. · Change device parameter preferences and much more... Note: 1)When using the app, make sure your device is within the Bluetooth range. Please avoid moving too far away from the device. 2)Due to the upgrading and updang of Temtop APP, the actual operaon may be slightly different from the above descripon, please follow the current guidelines within Temtop APP. 11 Air Quality Detector x 1 M10+ Manual x 1 USB Cable x 1 Q: Why is the test result abnormal? A: Please check that the air inlet or outlet is not covered or that liquid has entered. Gently shake the detector during detecon to increase interacon with the surrounding air. The sensor may not recover, so please place the detector outside in a venlated area. Q: AQI/ PM2.5 and other values, why the measured value is inconsistent with the official announcement? A: The AQI/PM2.5 shown on the display is a measurement of the space where the device is located. The measured value published on the Internet or official websites is the average value of several monitoring points, and each measurement point will be different. At the same me, according to the regulaons of EPA and WHO, the AQI value is calculated based on the highest value among the five pollutants in the atmosphere on that day. In the past ten years, the local AQI in the United States has basically been calculated with the value of PM2.5/10, and somemes with the value of O3. 12 Q: Why is the PM2.5 reading constantly changing? A: PM2.5 concentraons in the environment are constantly changing, not only due to environmental factors such as changes in airflow, moisture, and wind paerns but also due to the presence of such familiar sources as smoking, cooking, vehicle emissions, smoke from coal burning/chimney/stoves, etc. All these may affect the concentraon of PM2.5 and lead to differences in the readings. Q: Why is CO2 data high? A: The user's environment may be poorly venlated,resulng in high CO2 concentraon; it is recommended that the user place the product in an outdoor venlated place for 10 minutes. If the data is sll high, the customer is advised to perform a CO2 calibraon via the APP. Q: What is TVOC and what are the common sources in households? A: TVOC (Total Volale Organic Compounds) refers to a variety of chemical substances that easily evaporate into the air at room temperature. The TVOC sensor behaves similarly to the human nose and reflects changes in the relave intensity of indoor TVOC on a scale from 1 to 500. Common sources of TVOCs in the home include alcohol, air fresheners, citrus fruits, scented candles, paints, cleaning supplies, pescides, building materials and furniture, inks, glues, and various cosmecs. Q: Why are the TVOC data readings very high/out of range when with the detectors on? A: Being packed in an ink-printed box may interfere with the sensor over me due to the organic volales le in the packaging. Therefore, once unpacked, please place the detector in a venlated area to help speed up its data recovery. Q: Why is the temperature high when charging? A: The temperature and humidity sensor is located inside the product. When charging, a large amount of heat will be generated, causing the actual temperature of the product to rise. 13 FCC Requirement FCC Warning statement: This device complies with part 15 of the FCC Rules. Operaon is subject to the following two condions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received,including interference that may cause undesired operaon. Any Changes or modificaons not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protecon against harmful interference in a residenal installaon. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instrucons,may cause harmful interference to radio communicaons. However, there is no guarantee that interference will not occur in a parcular installaon. lf this equipment does cause harmful interference to radio or television recepon, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separaon between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC RF exposure statement: The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condion without restricon. 14 Warranty Temtop warrants the included detector for 1 year from the date of original purchase. The item can be exchanged or returned within 30 days if the defect is not caused by arficial damage. Before return or delivery for repair, please check if the following items are ready: * Including invoice, order number and etc. Temtop warranty does NOT include: · Malfuncon or damages caused by arficial damage or modificaon. · Other deliberate damages. · Damage caused by natural events. 15 Elitech Technology, Inc 2528 Qume Dr, Ste 2 San Jose, CA 95131 USA Tel: (+1) 408-898-2866 Tiktok: @Elitechus Facebook: @Elitech Twier: @elitechusa Youtube: @ElitechTechnologyInc Linkedin: @Elitech Technology, Inc Sales: sales@temtopus.com Website: www.temtopus.com Elitech Brazil Ltda R.Dona Rosalina,90-Lgara, Canoas-RS 92410-695,Brazil Tel: (+55)51-3939-8634 Sales: brasil@e-elitech.com Website: www.elitechbrasil.com.br Elitech (UK) Limited Unit 13 Greenwich Business Park, 53 Norman Road,London, SE10 9QF Tel: (+44)208-858-1888 Youtube: @elitech_uk Instagram: @elitechuk_ Facebook: @hvaccontrol Sales: sales@elitecheu.com Website: www.temtop.co.uk V1.1 Made In China