JØNI Induction Range IN 650

Technical Data

Model Number: 10000045497-TDA-000-01

Product Overview

The JØNI Induction Range IN 650 features cooking zones with an effect of 4 kW each. The power can be limited to a maximum of 16 or 20 Amp depending on the variant. The induction coils measure 210x210 mm per zone. Variants are available with an ordinary or vari frame, or as a tabletop model.

Accessories:

Technical Data - Electric

Refer to the user manual for important information regarding supply and connections.

3~400V+PE / 3~400V+N+PE, 50/60Hz

Type Zones (4kW) Power [kW] Current consumption [A] Leakage current [mA] Backup fuse (max.) [A]
IN 654F 4 16 25/25/25 <30 32
IN 654F max 16A 4 10,4 16/16/16 <30 32
IN 654F max 20A 4 13 20/20/20 <30 32

3~440V+PE, 50/60Hz

Type Zones (4kW) Power [kW] Current consumption [A] Leakage current [mA] Backup fuse (max.) [A]
IN 654F 4 16 22/22/22 <30 32

Technical Data - Ventilation

3~400V and 3~440V

Type Sensible [W] Latent [W] Steam [kg/h]
IN 654F 1120 448 0,66
IN 654F max 16A 728 291,2 0,43
IN 654F max 20A 910 364 0,53

The data is based on the German standard VDI 2052 for dimensioning of ventilation facilities. Values are based on average product usage. Actual demand may vary based on appliance efficiency, control, and usage. The simultaneity factor from VDI 2052 is not included.

Ingress Protection Class

IPX5

Dimensions of the Product

IN 654

Main Unit Dimensions:

Refer to the 'Dimensions for installation' section for space requirements around the appliance.

Additional Equipment - Electric Height Adjustment (Vari)

Dimensions:

Refer to the 'Dimensions for installation' section for space requirements around the appliance.

Additional Equipment - Tabletop Model (TT)

Dimensions:

Refer to the 'Dimensions for installation' section for space requirements around the appliance.

Fiddles

Dimensions:

This accessory requires floor mounting and cannot be combined with electric height adjustment.

Hand rail

The accessory requires floor mounting and cannot be combined with electric height adjustment.

Side Shelf

Dimensions:

Side shelves can be mounted on the left, right, or both sides of the appliance.

Fixing to the Floor

Dimensions:

Cannot be combined with electric height adjustment.

Power Management

The range can be delivered with current limitation according to DIN 18875. For connection, 1.5 mm² clamp terminals are located inside the appliance.

Signal to the Exhaust Hood

The range can be supplied with a potential-free contact set for signaling the extractor. The signal must be a maximum of 230 VAC and 8 A. For connection, 1.5 mm² clamp terminals are located inside the appliance.

Dimensions for Installation

IN 654

Clearance Requirements:

Diagram Description:

A top-down view showing the appliance footprint with minimum clearances. A: Minimum 1200mm electrical cable over the floor. Minimum 100mm clearance to inflammable materials. Minimum 10* clearance on sides and back.

IN 654 Vari

Clearance Requirements:

Diagram Description:

A top-down view showing the appliance footprint with minimum clearances for the Vari model. A: Minimum 850mm electrical cable over the floor. Minimum 100mm clearance to inflammable materials. Minimum 50* clearance on sides and back.

Models: IN 650 Induction Range, IN 650, Induction Range, Range

File Info : application/pdf, 7 Pages, 808.57KB

PDF preview unavailable. Download the PDF instead.

technical-data-for-in-650-0725-en Acrobat Elements 15.0 (Windows)