Instruction Manual for PHILIPS models including: DTK622-232 Network Gateway, DTK622-232, Network Gateway, Gateway

Installation Instructions DTK622-232 Network Gateway

1 day ago — * Auto: Emulates DTR signal to control data ow when RS-232 interface implementation does not use the DTR signal. 3. 2. IEC Pollution Degree II. This is a Class ...


File Info : application/pdf, 2 Pages, 896.19KB

PDF preview unavailable. Download the PDF instead.

DYN DTK622-232 II-R17
DTK622-232 Network Gateway

Installation Instructions
Instructions d'installation Installationsanweisungen Instrucciones de instalación Istruzioni per l'installazione Installatie-instructies  

Devices must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations.
Les appareils doivent être installés par un électricien diplômé conformément à tous les codes et réglementations électriques et de construction nationaux et locaux.
Die Geräte sind von einem qualifizierten Elektriker in Übereinstimmung mit allen geltenden Vorschriften zu installieren.

Los dispositivos deben ser instalados por un electricista calificado y cumpliendo todas las normas y regulaciones, tanto nacionales como locales, sobre instalaciones eléctricas y obras.
I dispositivi devono essere installati da un elettricista qualificato in conformità con le norme locali e nazionali vigenti in materia di costruzioni edilizie e installazione di impianti elettrici.
De apparaten moeten worden aangebracht door een gekwalificeerde elektricien en in overeenstemming met alle nationale en plaatselijke elektriciteits- en bouwvoorschriften.

   / 
.

X 2

91 mm (3.58 in)

1 IEC Overvoltage Category III

12 V 20 mA

RS-485 DyNet 2 x RJ12

GND
5432 1 98 7 6
RS-232 DB9 Female socket

1 - LOOP 2 - RX 3 - TX 4 - DTR 5 - GND 6 - LOOP 7 - NC 8 - NC 9 - LOOP

40° C (104° F) 0° C (32° F)

95%

51 mm (2.01 in) 24 mm (0.94 in)

SHLD GND D+ D+12 V

2 RS-232
IEC Pollution Degree II 3

GND D+ D-
+12 V

RS-485 DyNet

DyNet/Auto
* DyNet: Pin 4 DTR (Data Terminal Ready) controls data flow between RS-232 and RS-485 ports. * Auto: Emulates DTR signal to control data flow when RS-232 interface implementation does not use the DTR signal.

This is a Class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures.

© 2023 Signify Holding. All rights reserved. Specifications are subject to change without notice. No representation or warranty as to the accuracy or completeness of the information included herein is given and any liability for any action in reliance thereon is disclaimed. Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V. All other trademarks are owned by Signify Holding or their respective owners.

www.dynalite.com
AZZ 376 0823 R17

