MU04 Installation and User's Guide

http://www.homebandc.com/

Important Safety Instructions

Read all instructions carefully before proceeding.

DANGER - To reduce the risk of electric shock:

  1. Always unplug this furnishing from the electrical outlet before cleaning.

WARNING - To reduce the risk of burns, fire, electric shock, or injury to persons:

  1. Unplug from outlet before putting on or taking off parts.
  2. Close supervision is necessary when this furnishing is used by, or near children, invalids, or disabled persons.
  3. Use this furnishing only for its intended use as described in these instructions. Do not use attachments not recommended by the manufacturer.
  4. Never operate this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Return the furnishing to a service center for examination and repair.
  5. Keep the cord away from heated surfaces.
  6. Never operate the furnishing with the air openings blocked. Keep the air openings free of lint, hair, and the like.
  7. Never drop or insert any object into any opening.
  8. Do not use outdoors.
  9. Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
  10. To disconnect, turn all controls to the off position, then remove plug from outlet.
  11. WARNING: Risk of Injury - Keep children away from extended foot support (or other similar parts).
  12. WARNING: Risk of Electric Shock - Connect this furnishing to a properly grounded outlet only. See Grounding Instructions.
  13. For loading always put heavier items at the bottom and not near the top in order to help prevent the possibility of the furnishing tipping over.
  14. WARNING: Risk of Injury to Persons - do not place video equipment such as televisions or computer monitors on the product.
  15. WARNING: Risk of Injury to Persons - do not use this furnishing to support video equipment such as televisions or computer monitors.

Grounding Instructions

This product must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the product.

Before Beginning

Carefully read the instructions before beginning the installation.

DANGER! To avoid the risk of electrocution, please turn off the electricity mains before commencing the installation.

Maintenance / Entretien

Never use scouring powder pads, abrasive material, strong bleach or sharp instruments on metal components or glass. An occasional wiping down with a mild soap diluted in water is all that is needed to keep the mirror and aluminum parts looking new. Test products on a small inconspicuous surface prior to use.

Tools and Materials Required

Tools:

Hardware Listing:

Caution / Attention ⚠️

WARNING / AVERTISSEMENT

To avoid the risk of electrocution, please turn off the electricity mains before commencing the installation. We recommend the mirrors gets fitted by a qualified electrician.

Mirror Installation / Installation du Miroir

Placement / Placement

Select the desired position of the mirror. Level and mark the location.

Description of diagram: Two views of a mirror being marked for installation, showing different mounting bracket positions.

Support Location / L'Emplacement du Support

Mark the drilling locations ensure marking are leveled.

Vertical Assembly

Horizontal Assembly

Diagram showing measurements for drilling locations: 3 1/4", 4 3/16", 3 15/16"

Install Mounting Bracket / Installer le Support de Montage

Using a drill, make holes and fill with supplied plugs and install mounting bracket.

For drywall more than 10-12mm in thickness, please make sure to use specified drywall anchors for installation. For drywall with thickness less than 10-12mm, please make sure to install the brackets on the stud.

Diagrams illustrating three steps for installing the mounting bracket, including drilling, inserting plugs, and attaching the bracket with screws.

Screw / Vis 1 1/2"

Diagram showing screw dimensions 1/16"-1/8"

Connecting Electrical Wiring / Connexion de Câblage Électrique

WARNING / AVERTISSEMENT ⚠️

Diagram illustrating electrical wiring connections: Live (black), Neutral (white), and Ground (green) wires connecting from the wall to the mirror.

Please Note:

The colors referenced in the diagram above is based on conventional standards and may differ between households. If there is any confusion as to how these should be connected, please seek the help of a licensed professional electrician. Electric shock, fire hazard and death are possible consequences of poor wiring for none of which FOCA will be held liable.

Mirror Installation / Installation du Miroir

Placement / Placement

Place the mirror against the wall and slide down as shown in image 2.

Diagram showing the mirror being slid down onto the mounting brackets.

User's Guide / Guide de l'utilisateur

Caution / Attention

Touch button will be functional only after 3 seconds of power-up.

Short Touch / Bref touché (<1s)

Diagrams illustrating the touch button functions: ON/SUR, OFF/OFF.

Operate after LED luminaire is switched on

Short Touch / Bref touché (<1s)

Diagrams illustrating LED light control: turning on/off, changing brightness levels (5%, 30%, 60%, 100%), and activating the defogger.

Long Touch / Longtemps touché (>1s)

Diagrams illustrating long touch functions: turning on/off the defogger, and adjusting LED brightness from 5% to 100% and vice versa.

Caution / Attention

Power lines out of wall from the shadow area which is 4 inches from the mirror edge and 12 inch from the buttons line.

Diagram showing dimensions for power line exit point relative to the mirror edge and button line.

Models: MU04 Round Corner Rectangular Frame Less, MU04, Round Corner Rectangular Frame Less, Corner Rectangular Frame Less, Rectangular Frame Less, Frame Less