Installation Guide for DOMADOO models including: IOMZB-110 IO Module, IOMZB-110, IO Module, Module
DOMADOO - Module IO Zigbee 3.0 - 4 entrées contact sec 2 sorties NO/NC (ON/OFF ou impulsion)
DOMADOO - Zigbee 3.0 IO module - 4 dry contact inputs 2 NO/NC outputs (ON/OFF or pulse)
Do not paint the device. Version 1.7. IO Module. INSTALLATION MANUAL. Resetting. With the IO Module, you can connect wired devices to a Zigbee network ...
eng IO Module INSTALLATION MANUAL Version 1.7 Product description With the IO Module, you can connect wired devices to a Zigbee network. Providing four inputs and two outputs, the IO Module works as a bridge between wired devices and a control system over Zigbee networks. making the IO Module suitable for use in alarm systems. Disclaimers CAUTION: · Choking hazard! Keep away from children. Contains small parts. · Please follow the guidelines thoroughly. The IO Module is a preventive, informing device, warning or protection will be provided, or that no property damage, theft, injury, or any similar situation will take place. Domadoo products cannot be held responsible in case any of the above-mentioned situations occur. Precautions · WARNING: For safety reasons, always disconnect the IO Module from the power socket before removing the front cover. · Do not remove the product label as it contains important information. · Do not open the IO Module. · Do not paint the device. Placement Connect the IO Module to a device that is located at a temperature between 0-50°C. Connecting to wired device wired devices: doorbells, window blinds, wired security devices, heat pumps and more. and outputs: a. IN4 IN3I IN2 IN1 NC 2 COM 2 NO 2 NC 1 COM 1 NO 1 Inputs are internal pull up Output max load 1A 1E4 5 - 28 V d.c. T50 USB PWR RST LED IN1 IN2 IN3 IN4 NC2 Inputs with internal Pull Up. Must be shorted to IO Module GND for signal IO Module GND Normally Closed for Relay Output 2 COM2 Common for Relay Output 2 NO2 Normally Open for Relay Output 2 NC1 Normally Closed for Relay Output 1 COM1 Common for Relay Output 1 NO1 Normally Open for Relay Output 1 5-28 V d.c. Power Supply NOTE: Use "5-28 V" or "USB PWR". If both are connected "5-28V" is the primary Power Supply. USB PWR Power Supply NOTE: USB PWR is then used as fall back in case "5-28 V" is disconnected. RST Reset LED User Feedback Getting started 1. When the device is connected and powered up, the IO Module will start searching (up to 15 minutes) for a Zigbee network to join. While the IO Module is searching for a Zigbee network to join, the yellow LED 2. Make sure that the Zigbee network is open for joining devices and will accept the IO Module. 3. successfully joined the Zigbee network. 4. If the scanning has timed out, a short press on the reset button will restart it. b. Resetting Resetting is needed if you want to connect your IO Module to another gateway or if you need to perform a factory reset to avoid abnormal behavior. STEPS FOR RESETTING 1. Connect the IO Module to a power outlet. 2. Press and hold the reset button with a pen (see Illustration b). 3. While you are holding the button down, the c. 4. numerous times in a row. 5. After you release the button, the LED shows Modes SEARCHING GATEWAY MODE · In case of a bad or wireless weak signal, change the location of the IO Module. Otherwise, you can relocate your gateway or strengthen the signal with a smart plug. · If the search for a gateway has timed out, a short press on the button will restart it. Disposal Dispose the product properly at the end of its live. This is electronic waste which should be recycled. FCC statement expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on receiver is connected. · Consult the dealer or an experienced radio/ TV technician for help. This device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. this device must accept any interference received, including interference that may cause undesired operation. IC statement English This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions: 1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device. This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. Français L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : 1. L'appareil ne doit pas produire de brouillage; 2. L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Cet équipement est conforme aux limites d'exposition aux radiations IC CNR-102 établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec une distance minimale de 20 cm entre le radiateur et votre corps. ISED statement Innovation, Science and Economic Development Canada ICES-003 Compliance Label: CAN ICES-3 (B)/NMB-3(B). IN ACCORDANCE WITH THE DIRECTIVES · Radio Equipment Directive (RED) 2014/53/EU · RoHS Directive 2015/863/EU amending 2011/65/EU · REACH 1907/2006/EU + 2016/1688 its compliance with the European Directives which apply to the product and, in particular, its compliance with the harmonized standards andAdobe Illustrator 26.1 (Macintosh) Adobe PDF library 16.04