User Manual for Shenzhen Hobk Electronic Technology models including: HBK-A01, HBKA01, 2A4H6HBK-A01, 2A4H6HBKA01, HBK-A01 Standalone Access Control, Standalone Access Control
SHENZHEN HOBK ElECTRONIC TECHNOLOGY CO., LTD HBK-A01 2A4H6HBK-A01 2A4H6HBKA01 hbk a01
Standalone Access Control User Manual HBK-A01 1 Packing List Name Quantity Remarks Access Keypad 1 User Manual 1 Plastic Anchors 4 Ø6mmx25mm, used for fixing Self-Tapping Screw 4 Ø4mmx25mm, used for fixing 2 Introduction This RFID card access control unit controls 1 door, and it uses ST MCU assuring stable performance and low-power circuit makes long service life. OMRON power relay with 10A switching capacity provides an excellent switching performance for electric locks. It is widely used in factories, houses, residential quarters, offices, mechanical and electrical control equipment and so on. 3 Features Full programming from the keypad. Supports Card, PIN, Card + PIN, Card or PIN. Can be used as standalone keypad. Adjustable door open time. Very low power consumption. Lock output current short circuit protection. With bell function, supports external bell. Built-in buzzer. Red, blue, white, yellow and green LED indicators display the working status. 4 Specifications Operating Voltage 12VDC Lock Output Load Max. 1.5A Card Capacity 500 Card Type Standard 125KHz EM PIN Capacity 500 Door Relay time 0-99 seconds Card Reading Distance Max. 6cm Operating Temperature -40 60 Idle Current 50mA Operating Humidity 10%-90%RH Waterproof No Shell Material PC + ABS Product Weight 100g Shell Size 100x100x18.5mm Wiring Connections Electric Lock, Exit Button, External Bell 5 Installation Remove the back cover from the keypad Drill 4 holes on the wall for the self-tapping screws and 1 hole for the cable Put the supplied rubber plugs into the 4 holes Fix the back cover firmly on the wall with 4 self-tapping screws Thread the cable through the cable hole Attach the keypad to the back cover 6 Wiring Diagram Common Power Supply Diagram: Special Power Supply Diagram: 7 Sound and Light Indication Operation Status Standby PIN only mode Other mode Press # Press # # In the programming mode When a menu is waiting to be selected When a menu has been selected Unlock the lock Enter the PIN Operation successful Operation failed Press digit key 8 Operation Guide LED Indicator White Red Flash yellow Yellow Flash blue Blue Green Blue Flash green 1 time Flash red 3 times Buzzer A short beep A short beep 3 Short beeps A short beep Purpose To enter the programming mode Operation # Admin Password # To return to previous menu in # programming the mode Remarks The default factory admin password is 123456. The keypad will exit from the programming mode automatically if there is no operation in 30 seconds. To exit from the programming * mode Note that the following operations must be done in the programming mode To change the admin password Basic Operation 0 New Admin Password # Repeat New Admin Password # 0 Read Card 1 Read Card 2......Read Card N # The admin password can be 4-8 digits long. To add card users To add users 1 User ID Number # Read Card # 1 2 User ID Number # PIN # The user ID number is any 4-digit number from 0001 to 9999. Users can be added continuously by repeating the operation. 0 Read Card 1 Read Card 2......Read Card N # 1 User ID Number # To delete users 2 2 8 digits or 10 digits format card number # To add a card user with ID number To add or change a PIN user Users can be deleted continuously. The cards can be deleted when they are broken or lost. For example, the card number is 0006307890 09616434, and you can input 0006307890 or 09616434. To set a super open password To set door open mode To set door unlock time 6 1 3 0000 # Super open password # Repeat super open password # 3 To delete all users Attention: Delete all PIN users & card users except super open password. Only can set one set of super open password which has the highest permission to open the door and it can be used to open the door in any door open mode. 0000 # To delete the super open password 0 # 4 1# 2 # Entry is by either Card or PIN (Default) Entry is by Card and PIN together Entry is by PIN only 3 # 5 XX # Entry is by Card only XX is any number from 0 to 99. The factory default setting is 3 seconds. Advanced Application XX # To set Multi-cards to open the door XX is any number from 1 to 10. The factory default setting is 1. The door will open only when the quantity of the valid cards which it reads is up to the quantity you set. It is only for Card Only mode. Alarm Setting 0 # 7 1 To set anti-tamper alarm 1 # OFF (Default) ON System Setting 0 # 8 1 To set keypad output mode 1 # Default value, to set the output mode of the keypad to Normal Mode. After an unlock operation, the lock is unlocked, then the lock will be locked automatically after the door unlock time you set is up. To set the output mode of the keypad to Toggle Mode. After an unlock operation, the lock will keep unlocking until there is another unlock operation again, then the lock will keep locking, and so on. Optional Setting 0 # 9 1 To Set Buzzer 1 # ON (Default) OFF Remarks: All passwords can be 4 to 8 digits long, but you can't set every digit as zero. Note that the following operations must be done out of the programming mode To set or change a PIN of an added card To reset to the default admin password To reset to the default factory setting ## Read an Added Card PIN # Repeat PIN # 1Disconnect power from the device 2Press 00 # within 5 seconds after powering the device back up. This operation only resets the admin password to 123456, and it will not delete the users and settings. 1Disconnect power from the device This operation only resets the device to 2Press 99 # within 5 seconds after powering the device back up. the default factory settings. To Unlock the lock For a PIN user For a Card user Enter the PIN then press # Read Card For a Card and PIN user Read Card (the light will flashes green) then enter PIN # Troubleshooting: 1 Q: Why can't the door be unlocked after I swipe an added card? A: Please check whether you have set the door open mode to entry by PIN only. 2 Q: Why there is no sound when I press the numeric keypad A: Please check whether you have disabled buzzer. If yes, please enable buzzer according to the operation guide. 3 Q: Why there are 3 short beeps when I try to add a card user under programming mode.? A: This card has been added already. 4 Q: Why isn't the door unlocked when the LED indicator keeps flashing green after I swipe the added card? A: You have set the door open mode to entry by Card and PIN, please unlock the door by using card and PIN together. 5 Q: How to replace the card which was corresponding to a certain user ID number? A: Please delete this user ID number firstly and then re-add it. FCC Statement Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions (1)this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.Mac OS X 10.12 Quartz PDFContext Word