Instruction Manual for Lindab models including: RJFP20, RJFP30, RJFP40, PRJ RJFP20 Pressure Control Damper, PRJ RJFP20, Pressure Control Damper, Control Damper

Installation instruction

Lindab | Quick Selection Tool


File Info : application/pdf, 7 Pages, 2.61MB

PDF preview unavailable. Download the PDF instead.

PRJ installation GLOBAL ?t=507299968
lindab | for a better climate

Lindab PRJ

Installation instruction - UK Asennusohje - FI
Montageanleitung - DE Istruzioni di montaggio - IT Instructions de montage - FR

© 2024.03 Lindab Ventilation. All forms of reproduction without written permission are forbidden.

is the registered trademark of Lindab AB.

Lindab's products, systems, product and product group designations are protected by intellectual property rights (IPR).

lindab | for a better climate
Installation instruction
Product Tuote Produkt Prodotto Produit

PRJ

Dimensions Mitat Maße Dimensioni Dimensions
2

d

b

d

L

L A

d

Dimension table

Flange type LS RJFP20 RJFP30 RJFP40

d mm 20 20 30 40

a

d

c

L mm 151 151 151 151

LA mm 147 147 147 147

c mm 115 115 115 115

Motor type table
Type UNI * UNI-M UNI-MR ** SPR * SPR-M SPR-MR ** FAS-MR **

Regulator VRU-D3-BAC VRU-M1-BAC VRU-M1R-BAC VRU-D3-BAC VRU-M1-BAC VRU-M1R-BAC VRU-M1R-BAC

*) Max 20 m measuring hose **) Measuring hose and probe not included.

Motor NM24A-VST NM24A-VST NM24A-VST NF24A-VST NF24A-VST NF24A-VST NMQ24A-VST

Lindab reserves the right to make changes without prior notice 2024-03-21

Installation instruction
PRJ in details Measuring hose

lindab | for a better climate
PRJ

Duct prope

Belimo motor

Damper regulator shaft

Actuator

Duct samble profiles

lindab |
Declaration of incorporation of partly completed machinery Försäkran för inbyggnad av en delvis fullbordad maskin Inkorporeringserklæring for delmaskine Erklärung für den Einbau einer unvollständigen Maschine La déclaration d'incorporation de quasi-machines
.lindab.com

3xØd





6xØd





4xØd





Ød

Ød



Ød

Motor and actuator mounting plate
Damper blades Remember damper blades shall be installed horizontal. Not Vertical !

Joint flange profiles RJFP or LS-profile
Declaration of incorporation of partly completed machinery leaflet
lindab | for a better climate

Declaration of incorporation of partly completed machinery Försäkran för inbyggnad av en delvis fullbordad maskin Inkorporeringserklæring for delmaskine Erklärung für den Einbau einer unvollständigen Maschine La déclaration d'incorporation de quasi-machines
www.lindab.com

Lindab reserves the right to make changes without prior notice

3

2024-03-21

lindab | for a better climate
Installation instruction
Mounting of PRJ Kannakointi PRJ Montage des PRJ Montaggio di PRJ Montage de PRJ

PRJ

1. Drill a hole Ø10 mm in the duct.

2. Assembly the rubber gasket, flange and probe.

3. Mount the probe on the duct,

make sure the probe points

1

against the air direction.

2
4. Mount the hose.

The probe shall point against the air direction in the duct.
3

4

Lindab reserves the right to make changes without prior notice

2024-03-21

Installation instruction
Balancing Säätöohjeet Einregulierung Bilanciamento Réglage

lindab | for a better climate
PRJ

Universal controllers UNI(-M) / SPR(-M) / FAS(-M)

Belimo Service Tool ZTH-EU
*
Belimo PC-Tool MFT-P via ZTH-EU
Belimo Assistant App with NFC

**
Belimo Assistant App with Bluetooth via ZIP-BT-NFC

Note *) Note **)

**
Modbus/Bacnet/KNX settings can be done with ZTH-EU, PC-Tool, or Belimo Assistant App. Belimo Assistant App works with all Universal controllers.

Lindab reserves the right to make changes without prior notice

5

2024-03-21

lindab | for a better climate
Installation instruction

PRJ

Maintenance: Huolto Wartung Manutenzione Entretien

The visible parts of the product can be wiped with a damp cloth. The damper and and duct can be cleaned through the duct system or demounted. Do not blow into the plastic hoses mounted on the Belimo unit, as this can damage the flow/membrane sensors.

Cleaning the measuring probe Please demount the hose and use clean air to clean the hose and measuring probe.

Mounting hose Put the hose back followed by squeezing the black tightness rings back.

Mounting hose step 1 Put the hose back (bottom slot)

Mounting hose step 2 Squeeze the black tightness rings back.

6

Lindab reserves the right to make changes without prior notice

2024-03-21

Most of us spend the majority of our time indoors. Indoor climate is crucial to how we feel, how productive we are and if we stay healthy.
We at Lindab have therefore made it our most important objective to contribute to an indoor climate that improves people's lives. We do this by developing energy-efficient ventilation solutions and durable building products. We also aim to contribute to a better climate for our planet by working in a way that is sustainable for both people and the environment.
Lindab | For a better climate

www.lindab.com

For a better climate



References