Instruction Manual for CSI Controls models including: CSION 3R Alarm System, 3R Alarm System, Alarm System
CSI Controls - CSI Controls CSION 3R-01HR Indoor/Outdoor Alarm w/Float Red LED 115V #CP-CSI10
CSI Controls - CSI Controls CSION 3R-01HYTB Indoor/Outdoor Alarm w/Float Yellow LED, Terminal Block, 115V #CP-CSI1
File Info : application/pdf, 2 Pages, 1.11MB
DocumentDocumentNORMALLY OPEN COMMON NORMALLY CLOSED 1072479A 03/22 + Electrical Warnings / Advertencias Eléctricas Failure to follow these precautions could result in serious injury or death. Replace the float switch immediately if cable becomes damaged or severed. Keep these instructions with warranty after installation. This product must be installed in accordance with National Electric Code, ANSI/NFPA 70 so as to prevent moisture from entering or accumulating within boxes, conduit bodies, ttings, float housing, or cable. ELECTRICAL SHOCK HAZARD Disconnect power before installing or servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes. EXPLOSION OR FIRE HAZARD Do not use this product with flammable liquids. Do not install in hazardous locaons as defined by Naonal Electrical Code, ANSI/NFPA 70. No obedecer estas precauciones podría resultar en lesiones serias o mortales. Reemplace el interruptor de flotador de inmediato si el cable está dañado o partido. Después de la instalación, guardar estas instrucciones junto con la garantía. Este producto debe ser instalado siguiendo el Código Eléctrico Nacional de EE.UU., ANSI/NFPA 70, para evitar la entrada o acumulación de humedad en cajas de conexión, conductos, acoples, carcaza del interruptor (flotador) o el cable. RIESGO DE CHOQUE ELÉCTRICO Desconecte el cable de alimentación antes de instalar este producto o de hacerle mantenimiento. La instalación y el mantenimiento de este producto deben ser efectuados por personal idóneo siguiendo las normas aplicables en cuanto a instalaciones eléctricas y plomería. RIESGO DE INCENDIO O EXPLOSIÓN No ulice este producto con líquidos inflamables. No lo instale en lugares peligrosos definidos como tales en el Código Eléctrico Nacional de Estados Unidos, ANSI/NFPA 70. Wiring Diagrams NOTE: INFEED ALARM POWER MUST MATCH VOLTAGE RATING ON THE FRONT OF THE ALARM. INFEED POWER 120 VAC ONLY ALARM TERMINAL BLOCK 1234567 ALARM N L1 FLOAT AUX ALARM CONTACTS 240VAC MAX/30VDC MAX 1.5 AMPS MAX NOTE: AUX ALARM CONTACTS USED TO TRIGGER SECONDARY REMOTE DEVICE IF NEEDED. NON POWERED DRY CONTACT Items Needed / Elementos Necesarios Included with CSION® 3R Alarm Viene con la alarma CSION® 3R Alarm Included with Optional Float Switch Viene con el interruptor de flotador opcional Not included No incluido v ORDERABLE OPTION v PUMP TERMINAL BLOCK INFEED POWER L2/N 1 120/208/240 VAC L1 PUMP FLOAT 2 G NOTE: INFEED PUMP POWER MUST 3 MATCH PUMP VOLTAGE. 4 PUMP GROUND PUMP L1 PUMP L2/N PUMP CSI CONTROLS® FIVE-YEAR LIMITED WARRANTY Five-Year Limited Warranty. For complete terms and conditions, please visit www.csicontrols.com. GARANTÍA LIMITADA DE CINCO AÑOS DE CSI CONTROLS® Cinco años de garantía limitada. Para consultar los términos y condiciones, visite el portal www.csicontrols.com. Voltage 120 VAC Model Specifications Especificaciones Voltaje Modelo de 120 V CA Primary: 120 VAC, 50/60 Hz, 3.8 watts max. (alarm condition) Secondary: 9 VDC Primario: 120 V CA, 50/60 Hz, 3,8 watts máx. (estado de alarma) Secundario: 9 V CC Enclosure Indoor/Outdoor Gabinete Interior/Exterior CSION® 3R Alarm / Alarma Installation Instructions / Instrucciones de instalación English Español This alarm system monitors liquid levels in lift Este sistema de alarma vigila la altura del líquido pump chambers, sump pump basins, holding tanks, en cámaras de bombas aspirantes, en cubetas de sewage, agricultural, and other water applications. bombas de sumidero, en tanques de retención, y The CSION® 3R indoor/outdoor alarm can serve as a high or low level alarm depending on the float switch en aplicaciones como aguas residuales, agricultura y otros sistemas de aguas. model used. This easy-to-install alarm features an La alarma para uso interior y exterior CSION® 3R innovative, sleek 2-color molded enclosure which puede utilizarse como alarma de nivel alto o bajo, integrates the LED translucent beacon (LED dependiendo del modelo del interruptor de nivel. Esta available in red or yellow). alarma es fácil de instalar y trae una innovadora caja moldeada de dos colores, que integra la luz The alarm sounds and the upper half of the housing LED roja translúcida de aviso (y también una luz illuminates when a potentially threatening liquid de aviso de color amarillo. level condition occurs. The audible alarm can be silenced by pressing the Test/Silence button, but Ante una condición potencialmente peligrosa del the alarm light will remain on until the condition is nivel de líquido, la bocina de la alarma suena y remedied. Once the condition is cleared, the alarm la parte superior de la caja se ilumina. La alarma will automatically reset. A green "power on" light audible se silencia pulsando el botón de prueba/ indicates power to the alarm panel. silencio (Test/Silence) quedando encendida la luz hasta que se resuelva la situación. La alarma retorna automáticamente a su condición inicial una vez se resuelva la condición que la activó. La luz verde de encendido ("power on") indica que hay alimentación al panel de la alarma. + 1-800-746-6287 techsupport@sjeinc.com www.csicontrols.com Technical Support Hours: Monday - Friday, 7 A.M. to 6 P.M. Central Time Soporte técnico, Horario: lunes a viernes, 7 A.M. a 6 P.M. hora del Centro PN 1072479A 03/22 © 2022 SJE, Inc. All Rights Reserved. CSI CONTROLS is a trademark of SJE, Inc. Mount the alarm enclosure using existing upper and lower mounting tabs. Install float switch at desired activation level. Acvaon Level Nivel de acvación Remove screw from front of lower cover. Lift bottom of lower cover out slightly. Slide lower cover down until it is clear of the upper cover and remove. Determine "conduit-in" location on alarm. See bottom of enclosure for cord placement indicator marks. Drill holes for conduit entry. Bring float switch and power cable through conduit and wire to 7 position terminal block. Connect ground wire to ground termination post. NOTE: Seal conduit to prevent moisture or gas from entering enclosure. Restore power and check alarm operation after installation (high level application shown). G Test alarm weekly to insure proper operation. Auxiliary contacts Contactos auxiliares Incoming power Alimentación de entrada Float Flotador Ground Tierra Power Conduit Conducto de alimentación Float Conduit Conducto del flotador Alarm O (High Level) Alarma desactivada (nivel alto) Alarm On (High Level) Alarma activada (nivel alto) 1 2 3456 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31