Owner's Manual for MEAN WELL models including: LPS-50 Series 50W Single Output Switching Power Supply, LPS-50 Series, 50W Single Output Switching Power Supply, Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply, Supply
LPS-50-15 MEAN WELL - РКС Компоненти - РАДІОМАГ
File Info : application/pdf, 2 Pages, 109.24KB
DocumentDocument50W Single Output Switching Power Supply LPS-50 series User's Manual Features : Universal AC input / Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection Small and compact size Built-in remote ON-OFF control LED indicator for power on 100% full load burn-in test Low profile:23mm thickness GTIN CODE 2 years warranty MW Search: https://www.meanwell.com/serviceGTIN.aspx SPECIFICATION UL62368-1 Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 2000000000 BS EN/EN62368-1 IEC62368-1 TPTC004 MODEL LPS-50-3.3 LPS-50-5 LPS-50-12 LPS-50-15 LPS-50-24 LPS-50-48 DC VOLTAGE 3.3V 5V 12V 15V 24V 48V RATED CURRENT 10A 10A 4.2A 3.4A 2.1A 1.1A CURRENT RANGE 0 ~ 12A 0 ~ 12A 0 ~ 5A 0 ~ 4.1A 0 ~ 2.5A 0 ~ 1.3A RATED POWER 33W 50W 50.4W 51W 50.4W 52.8W OUTPUT PEAK LOAD(10sec.) Note.4 39.6W RIPPLE & NOISE (max.) Note.2 50mVp-p VOLTAGE ADJ. RANGE 3 ~ 3.6V VOLTAGE TOLERANCE Note.3 ±3.0% LINE REGULATION ±1.0% LOAD REGULATION ±3.0% 60W 50mVp-p 4.5 ~ 5.5V ±3.0% ±1.0% ±3.0% 60W 80mVp-p 10.8 ~ 13.2V ±2.0% ±1.0% ±2.0% 61.5W 80mVp-p 13.5 ~ 16.5V ±2.0% ±1.0% ±2.0% 60W 80mVp-p 21.6 ~ 27.2V ±1.0% ±1.0% ±1.0% 62.4W 100mVp-p 43.2 ~ 52.8V ±1.0% ±1.0% ±1.0% SETUP, RISE TIME 500ms, 40ms/230VAC 500ms, 40ms/115VAC at full load HOLD UP TIME (Typ.) 70ms/230VAC 12ms/115VAC at full load VOLTAGE RANGE FREQUENCY RANGE 90 ~ 264VAC 47 ~ 63Hz 127 ~ 370VDC EFFICIENCY(Typ.) 75% 81% 82% 84% 85% 86% INPUT AC CURRENT 115VAC 0.9A 1.2A (Typ.) 230VAC 0.6A 0.8A INRUSH CURRENT (Typ.) COLD START 18A/115VAC 35A/230VAC LEAKAGE CURRENT <1mA / 240VAC OVERLOAD PROTECTION OVER VOLTAGE FUNCTION REMOTE ON/OFF WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE EMC (Note 5) ISOLATION RESISTANCE EMC EMISSION 122 ~ 160% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 3.8 ~ 4.45V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V Protection type : Hiccup mode, recovers automatically after fault condition is removed RC+/RC- : 0 ~ 0.8V power on ; 4 ~ 10V power off -20 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -20 ~ +85, 10 ~ 95% RH ±0.04%/ (0 ~ 50) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 57.6 ~ 67.2V EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, criteria A, EAC TP TC 020 OTHERS NOTE MTBF 3138.2K hrs min. Telcordia SR-332 (Bellcore) ; 491.4K hrs min. MIL-HDBK-217F (25) DIMENSION 195*55*23mm (L*W*H) PACKING 0.24Kg; 48pcs/12.5Kg/0.87CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1F & 47F parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) 6. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:LPS-50-SPEC 2024-02-23 Downloaded from Arrow.com. 55 45 50W Single Output Switching Power Supply Mechanical Specification 195 185 CN1 5 4 3 2 1 AC FUSE F3.15A/250VAC FS1 LPS-50 series Unit:mm CN3 1 2 1 2 CN2 3 4 SVR1 LED 4-3.8 23 3 max. AC Input Connector (CN1) : JST B5P-VH or equivalent Pin No. Assignment Mating Housing Terminal 1 AC/L 2,4 No Pin JST VHR JST SVH-21T-P1.1 3 AC/N or equivalent or equivalent 5 FG Block Diagram I/P EMI FILTER RECTIFIERS & FILTER POWER SWITCHING DC Output Connector (CN2) : JST B4P-VH or equivalent Pin No. Assignment Mating Housing Terminal 1,2 -V JST VHR JST SVH-21T-P1.1 3,4 +V or equivalent or equivalent Remote ON/OFF Connector(CN3):JST B2B-XH or equivalent Pin No. Assignment Mating Housing Terminal 1 RC+ JST XHP JST SXH-001T-P0.6 2 RC- or equivalent or equivalent : Grounding Required CN1:Pin 5 is safety ground fosc : 60KHz RECTIFIERS +V & FILTER -V FG Derating Curve DETECTION O.L.P. PWM CONTROL CIRCUIT O.V.P. RC+ RC- Static Characteristics (15V) 100 80 1 Convection 60 2 18CFM Forced Air 40 20 2 1 -20 0 10 20 30 40 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE () 21 300 18 250 15 200 12 150 9 100 6 50 3 25 60 90 100 120 140 160 180 200 220 240 264 INPUT VOLTAGE (V) 60Hz File Name:LPS-50-SPEC 2024-02-23 LOAD (%) OUTPUT VOLTAGE (V) OUTPUT RIPPLE (mVp-p) Downloaded from Arrow.com.