Instruction Manual for finder models including: 80.51, 80.51 Multi-Function Modular Timer, Multi-Function Modular Timer, 80.51-P
• Open Type Device • Pollution degree 2 Installation Environment • Maximum Surrounding Air Temperature 40°C • Use 60/75°C copper (Cu) conductor only and
Série 80 - Temporizador modular 1 - 6 - 8 - 16A - Finder
File Info : application/pdf, 1 Pages, 651.72KB
DocumentDocument80.51 80.51-P 80.51.0.240.x000 UN (24...240) V AC (50/60 Hz) / DC Umin 17 V AC / DC Umax 265 V AC / DC P < 1.8 VA (50 Hz) / <1 W 1 CO (SPDT) 8 A 250 V AC AC1 AC15 (230 V AC) M (230 V AC) DC1 (30/110/220) V 2000 VA 400 VA 0.3 kW (8/0.3/0.12)A (10...+50)°C IP20 1 A B C D 88.8 mm 60.8 mm 17.5 mm LED UN 15 - 18 15 - 16 15 - 18 15 - 16 15 - 16 15 - 16 15 - 18 (1x6 / 2x4) mm2 (1x4 / 2x2.5) mm2 (1x10 / 2x12) AWG (1x12 / 2x14) AWG A · Open Type Device · Pollution degree 2 Installation Environment · Maximum Surrounding Air Temperature 40°C · Use 60/75°C copper (Cu) conductor only and wire ranges No. 1418 AWG, stranded or solid B · Terminal tightening torque of 7.1 Ib.in. (0.8 Nm) 80.51.0.240.P000 Utility Model - IB8051VXX - 10/21 - Finder S.p.A. con unico socio - 10040 ALMESE (TO) - ITALY 2 2a 80.51.0.240.P000 1 2b 1 2 2 10mm 10mm (0.75...1.5) mm2 (18...16) AWG (0.75...2.5) mm2 (18...14) AWG 3 4 4a 4c 4b 4d 4e ENGLISH 80.51 MODULAR TIMER, MULTI-FUNCTION 1 FRONT VIEW A Time scale rotary selector (Tmax) B Time setting (Tmin...Tmax) C LED D Function rotary selector 2 TERMINAL PUSH-IN CONNECTION 2a Connection with stranded wire (without screwdriver in case of solid wire) 2b Disconnection of the electrical connection 3 TIME SCALES (Eg. T=10 min: set A= 20 m and B=10) 4 WIRING DIAGRAM AND FUNCTIONS NOTE Time scale and function must be set before energising the timer 4a Without signal START functions: Start via contact in supply line (A1) AI On-delay DI Interval SW Symmetrical flasher (starting pulse on) 4b External START functions: Start via contact into control terminal (B1) BE Off- delay with control signal CE On- and off- delay with control signal DE Interval with control signal on 4c Possible to control an external load, such as another relay coil or timer, connected to the signal start terminal B1 4d With DC supply, positive polarity has to be connected to B1 terminal (according to EN 60204-1) 4e A voltage other than the supply voltage can be applied to the command Start (B1), example: A1-A2 = 230 V AC B1-A2 = 24 V DC OTHER DATA Minimum control impulse: 50 ms. Recovery time: 100 ms. 35 mm rail mount (EN 60715). WORKING CONDITIONS In conformity with the European Directive on EMC 2014/30/EU, the timer relay has a level of immunity, against radiated and conducted disturbances, considerably higher than requirements of EN 61812 -1 standard. However, devices like transformers, motors, contactors, switches and power cables may cause disturbances and even damage the timer electronic circuit. For that reason, the wiring cables must be as short as possible, and, when necessary, the timer shall be protected by the relevant RC network, varistor or surge voltage protector.Adobe PDF Library 15.0 Adobe InDesign 16.2 (Macintosh)