Installation Instructions: Current Sensor Cylinder Busbar Kit (D1h-D8h) for VLT FC Series

Description

The current sensor cylinder busbar kits include all parts required to install the cylinder busbars in D1h-D8h drives. Each cylinder busbar is inserted through the center of a current sensor during installation. For more information, see the current sensor kit installation instructions listed in Table 1.4.

Kit Ordering Numbers

Table 1.1 Ordering Numbers for Current Sensor Cylinder Busbar Kits

Kit numberKit description
176F6517300 A D1 LEM BB kit
176F6757300 A D2 LEM BB kit
176F6756500 A D2 LEM BB kit

Items Supplied

Table 1.2 Items Supplied with D1h/D3h/D5h/D6h Kit (176F6517)

ItemQuantity
Nomex sleeve3
U, V, W cylinder busbars1 set of 3
M6x90 screw3
Cylinder busbar mounting frame1
M6x16 screw3

Table 1.3 Items Supplied with D2h/D4h/D7h/D8h Kit (176F6756/176F6757)

ItemQuantity
Nomex sleeve3
U, V, W cylinder busbars1 set of 3
M8x70 screw3

Safety Information

Only qualified, Danfoss authorized personnel are allowed to install the parts described in these installation instructions. Handling of the drive and its parts must be done in accordance with the corresponding operating guide.

WARNING ELECTRICAL SHOCK HAZARD

VLT FC series drives contain dangerous voltages when connected to mains voltage. Improper installation, and installing or servicing with power connected, can cause death, serious injury, or equipment failure.

  • Only use qualified electricians for the installation.
  • Disconnect the drive from all power sources before installation or service.
  • Treat the drive as live whenever the mains voltage is connected.
  • Follow the guidelines in these instructions and local electrical safety codes.

WARNING DISCHARGE TIME

The drive contains DC-link capacitors, which can remain charged even when the drive is not powered. High voltage can be present even when the warning LED indicator lights are off. Failure to wait the specified time after power has been removed before performing service or repair work can result in death or serious injury.

  • Stop the motor.
  • Disconnect AC mains and remote DC-link power supplies, including battery back-ups, UPS, and DC-link connections to other drives.
  • Disconnect or lock PM motor.
  • Wait for the capacitors to discharge fully. The minimum waiting time is 20 minutes.
  • Before performing any service or repair work, use an appropriate voltage measuring device to make sure that the capacitors are fully discharged.

Cylinder Busbar Identification

Illustration 1.1 Current Sensor Cylinder Busbars

Depicts three distinct current sensor cylinder busbar kits. The first kit, labeled 176F6517, is for 90/110/132 kW power ratings, featuring a V-phase busbar of 64 mm [diameter] 16 mm and U/W-phase busbars of 71 mm [diameter] 16 mm. The second kit, 176F6757, is for 160 kW power ratings, with U/V/W-phase busbars measuring 49 mm [diameter] 19 mm. The third kit, 176F6756, is for 200/250 kW power ratings, with U/V/W-phase busbars measuring 49 mm [diameter] 25 mm.

Table 1.4 Comparison of Current Sensor Cylinder Busbar Kits

Busbar kitCurrent sensor kitKit descriptionInstallation instruction
176F6517176F6516300 A D1 retro fit kit300 A Current Sensor Kit for D1h/D3h/D5h/D6h Drives
176F6757176F3752300 A D2 retro fit kit300 A/500 A Current Sensor Kit for D2h/D4h/D7h/D8h Drives
176F6756176F3737500 A D2 retro fit kit300 A/500 A Current Sensor Kit for D2h/D4h/D7h/D8h Drives

Assembling the Current Sensor Cylinder Busbars in D1h/D3h/D5h/D6h Drives

WARNING NOMEX SLEEVES REQUIRED

The Nomex sleeves are required to maintain proper electrical protection. Failure to install the Nomex sleeves can result in personal injury or equipment damage.

  • Do not discard the Nomex sleeves.

Use the following steps to assemble the current sensor cylinder busbars in D1h/D3h/D5h/D6h drives. Refer to Illustration 1.2.

  1. Place the 3 Nomex sleeves over the cylinder busbars, 1 per busbar. Place the sleeve with the red marking on the short busbar.
  2. Insert 3 M6x90 screws through the center of the busbars and place the busbar mounting frame, 1 screw per busbar. The busbar with the red marking is the V busbar and is mounted in the middle.
  3. Retain 3 M6x16 screws to fasten the busbar mounting frame in the drive when installing the current sensors. The cylinder busbars are inserted through the centers of the current sensors. Refer to 300 A Current Sensor Kit for D1h/D3h/D5h/D6h Drives installation instruction.

Illustration 1.2 Current Sensor Cylinder Busbar Assembly in D1h/D3h/D5h/D6h Drives

Shows the assembly of current sensor cylinder busbars for D1h/D3h/D5h/D6h drives. The diagram illustrates the placement of components: 1. Cylinder busbar mounting frame, 2. Nomex tube, 3. Cylinder busbar, 4. M6x90 screw, 5. Assembled cylinder busbars, and 6. M6x16 screw.

Assembling the Current Sensor Cylinder Busbars in D2h/D4h/D7h/D8h Drives

WARNING NOMEX SLEEVES REQUIRED

The Nomex sleeves are required to maintain proper electrical protection. Failure to install the Nomex sleeves can result in personal injury or equipment damage.

  • Do not discard the Nomex sleeves.

Use the following steps to assemble the current sensor cylinder busbars in D2h/D4h/D7h/D8h drives.

  1. Place the 3 Nomex sleeves over the cylinder busbars, 1 per busbar.
  2. Insert 3 M8x70 screws through the center of the busbars, 1 screw per busbar.
  3. The cylinder busbars are inserted through the centers of the current sensors when installing the current sensors in the drive. See 300 A/500 A Current Sensor Kit for D2h/D4h/D7h/D8h Drives installation instruction.

Illustration 1.3 Current Sensor Cylinder Busbar Assembly in D2h/D4h/D7h/D8h Drives

Illustrates the assembly of current sensor cylinder busbars for D2h/D4h/D7h/D8h drives. The diagram shows the key components: 1. Nomex sleeve, 2. Cylinder busbar, and 3. M8x70 screw.

PDF preview unavailable. Download the PDF instead.

AN361179800554en-000201 Danfoss A/S

Related Documents

Preview Danfoss VLT® Frequency Converters 90-400 kW Installation Guide
Comprehensive installation guide for Danfoss VLT® Frequency Converters, models D1h-D8h (FC 102/FC 103/FC 202/FC 302), covering power ratings from 90-400 kW. Provides essential safety precautions and installation procedures for qualified personnel.
Preview Danfoss VLT Drive Installation Drawing and Specifications
Technical installation drawing and specification guide for Danfoss VLT® HVAC, AQUA, and Automation drives (FC 102, FC 103, FC 202, FC 301/302 series). Includes dimensional data, mounting information, terminal layouts, and model/typecode to frame size mappings.
Preview Danfoss VLT® Wireless Communication Panel LCP 103: Enhanced Drive Connectivity
Discover the VLT® Wireless Communication Panel LCP 103 from Danfoss, enabling wireless connectivity and remote management of VLT® drives via the MyDrive® Connect app for efficient commissioning, monitoring, and maintenance.
Preview VLT Frequency Converters Installation Guide
This guide provides essential information for the safe and effective installation of VLT Frequency Converters, 0.25-90 kW, including safety precautions, required tools, and installation steps.
Preview Danfoss VLT Safe Torque Off Operating Guide
This operating guide provides comprehensive information on the Safe Torque Off (STO) function for Danfoss VLT FC Series frequency converters, covering installation, commissioning, safety, and application examples.
Preview VLT® PROFINET MCA 120 Installation Guide | Danfoss
Comprehensive installation guide for the Danfoss VLT® PROFINET MCA 120 interface, covering setup, wiring, safety precautions, and troubleshooting for VLT® Frequency Converter Series FC 102, FC 103, FC 202, FC 301/302.
Preview Danfoss VLT® Advanced Harmonic Filter AHF 005/AHF 010 Design Guide
This design guide from Danfoss provides essential information for the VLT® Advanced Harmonic Filters AHF 005 and AHF 010. It covers harmonic principles, mitigation strategies, installation, selection, and programming for VLT® frequency converters.
Preview VLT® Programmable I/O MCB 115 Installation Guide | Danfoss
Installation guide for the Danfoss VLT® Programmable I/O MCB 115 option, detailing its use with VLT® FC drive series including HVAC, Refrigeration, AQUA, and AutomationDrive models. Covers safety, installation procedures, electrical specifications, and terminal configurations.