User Manual for Electriflex models including: CEHD50 Commercial Electric Water Heater, CEHD50, Commercial Electric Water Heater, Electric Water Heater, Water Heater, Heater

canada commercial accessory nsf5 kits electiflex hd series cehd 44710

NSF CONSTRUCTION COMMERCIAL ELECTRIC WATER HEATER INSTALLATION INSTRUCTIONS

PDF preview unavailable. Download the PDF instead.

canada commercial accessory nsf5 kits electiflex hd series cehd 44710
NSF CONSTRUCTION COMMERCIAL ELECTRIC WATER HEATER
INSTALLATION INSTRUCTIONS
THE MANUFACTURER OF THIS WATER HEATER WILL NOT BE LIABLE FOR ANY DAMAGE RESULTING FROM FAILURE TO COMPLY WITH THESE INSTRUCTIONS. READ THESE INSTRUCTIONS THOROUGHLY BEFORE STARTING.

For safety and convenience, the NSF construction components must be installed and serviced by a qualified technician.

Before proceeding with installation of this NSF kit, please assure that this water heater has been installed in accordance with local codes and/or ordinances. In the absence of local codes, this water heater must be installed in accordance with the National Electric Code ­ latest edition. Refer to Installation instructions provided with this water heater.

Assure the correct NSF kit for this water heater has been provided.

NSF Kit Required

Model

NSF Kit Part No.

CEHD50 (3 & 6 ELEM)

265-44542-06

CEHD80 (3 & 6 ELEM)

265-44542-07

CEHD120 (3 & 6 ELEM)

265-44542-08

CEHD50 (9 ELEM)

265-44542-09

CEHD80 (9 ELEM)

265-44542-10

CEHD120 (9 ELEM)

265-44542-11

Tools and Materials Required: RTV sealant (provided) Control box seal (provided) Two (2) sheet metal screws (provided) NSF label (provided) attached to these instructions Caulk gun ¼" nut driver and/or drive tool
Installation Procedure: 1. Place control box seal on top of control box sealing gap between control box and water heater jacket. Attach control box seal to control box using two (2) sheet metal screws (see Figure 1). 2. Seal water heater to floor using RTV sealant. Be sure to seal water heater completely to floor without leaving voids (see Figure 2). 3. Place NSF label on or adjacent to rating plate.

Figure 1