User Manual for APG Sensors models including: FLR Series Stem Mounted Multi Point Float Switch, FLR Series, Stem Mounted Multi Point Float Switch, Multi Point Float Switch, Float Switch, Switch
Stem Mounted Multi-Point Level Switch | APG Sensors
Resources - User Manual | APG Sensors
File Info : application/pdf, 12 Pages, 164.80KB
DocumentDocumentFLR Series Stem-Mounted, Multi-Point Float Switch User Manual Doc #9003284 Part #200383 Rev B1, 10/2024 CONTENTS INTRODUCTION III WARRANTY AND WARRANTY RESTRICTIONS IV Repair and Returns iv CHAPTER 1: SPECIFICATIONS AND OPTIONS 1 Dimensions 1 Specifications 2 Model Number Configurator 3 Wire Color Diagrams and Table 4 CHAPTER 2: INSTALLATION AND REMOVAL PROCEDURES AND NOTES 5 Tools Needed 5 Installation Notes 5 Mounting Instructions 5 Electrical Installation 6 Removal Instructions 6 CHAPTER 3: MAINTENANCE 7 General Care 7 ii INTRODUCTION Thank you for purchasing a FLR Multi-Point Stem Mounted Float Switch from APG. We appreciate your business! Please take a few minutes to familiarize yourself with your FLR and this manual. The FLR contains up to seven reed switches in a 1/2" Ø stainless steel stem and permanent magnets in the floats. As each float rises or falls with the level of the liquid, the magnet inside the float acts on the corresponding reed switch inside the stem to provide SPST switching action. Reading your label Every APG instrument comes with a label that includes the instrument's model number, part number, serial number, and a wiring pinout table. Please ensure that the part number and pinout table on your label match your order. iii WARRANTY AND WARRANTY RESTRICTIONS This product is covered by APG's warranty to be free from defects in material and workmanship under normal use and service of the product for 24 months. For a full explanation of our Warranty, please visit https://www.apgsensors.com/resources/warranty-certifications/warranty-returns/. Contact Technical Support to receive a Return Material Authorization before shipping your product back. Repair and Returns Should your FLR require service, please contact the factory via phone, email, or online chat. We will issue you a Return Material Authorization (RMA) number with instructions. · Phone: 888-525-7300 · Email: sales@apgsensors.com · Online chat at www.apgsensors.com Please have your FLR's part number and serial number available. See Warranty & Warranty Restrictions for more information. iv CHAPTER 1: SPECIFICATIONS AND OPTIONS Dimensions 3/4" NPT Hex Plug Mounting per order 1 Maximum Stem Length (L): 153 inches (3886.2 mm) l1 Distance, in inches, to first switch l2 Distance, in inches, to second switch Wetted Material: 316L Stainless Steel Notes: 1. Allow at least 2 inches from fixed mount connection to first switch location (l1), or up to 6 inches for slide connections 2. Allow 3 inches between switch locations(l2-l1, etc) 3. Allow 2 inches from last switch location to bottom of probe (L-lfinal). 2 L FLR Floats Float A/B 2.0" 51 mm 2.06" 52 mm Float C/D 1.38" 35 mm 1.63" 41 mm IMPORTANT: The switch points on an FLR with no housing CANNOT be moved, changed, or adjusted. 1 Specifications Performance Switch Points Maximum Stem Length Minimum Switch Separation Float Specific Gravity Up to seven 153 inches / 12.75 feet / 3890 mm 3 inches / 0.25 feet / 76 mm 0.59, 0.607, or 0.92 Accuracy Resolution Hysteresis ± 1/16 inch / 1.6 mm at each switch 0.06 inches / 1.5 mm Environmental Operating Temperature Hazardous Ratings -40 to 100°C / -40 to 212°F None Electrical Switch Rating Maximum Capacity Maximum Current (AC, 50/60 Hz) Maximum Current (DC) Maximum Voltage Lead Wires Switch B: 50 VA Switch C: 180 VA 0.5 A 0.5 A 120 VDC / 220 VAC #22 AWG, Teflon, 1 - 15 feet / 305 - 4570 mm Materials of Construction Stem Floats Floats Stops, Misc Hardware Mechanical Conduit Connection 316L Stainless Steel 316L Stainless Steel 316L Stainless Steel 3/4" NPTM 2 Model Number Configurator Model Number: FLR - _____ _____ - _____ - _____ - _____ - _____ - _____ AB C D E F G A. Mounting Type 0A Flat Face ANSI Flange 150# 3SF Triclamp 4T NPT Plug 150#, mounted outside tank B. Mounting Size 1.5* (NPT Plug only) 2* (Flange, Triclamp, or NPT Plug) 2.5* (Flange or NPT Plug) 3* (Flange or NPT Plug) *Note: Add an `S' after Mounting Size for Slide Connection. Note: 1.5 NPT Plug requires floats C or D. C. Housing W__ No housing. 3/4" NPT Plug above selected mount, lead wires 1 -15 feet, in 1 foot increments D. Reed Switch B 50 VA C 180 VA E. Number of Switch Points 1-7 Select the number of switch points required F. Float Type A 316L SS (2.06 in. diameter, 0.59 SG) B 316L SS (2.06 in. diameter, 0.92 SG) C 316L SS (1.63 in. diameter, 0.607 SG) D 316L SS (1.63 in. diameter, 0.92 SG) G. Probe Length (Inches) __ Inches (up to 153 inches) Switch Point Location(s) (Measured from process connection) 1 ____ inches (designate NO or NC position) 2 ____ inches (designate NO or NC position) 3 ____ inches (designate NO or NC position) 4 ____ inches (designate NO or NC position) 5 ____ inches (designate NO or NC position) 6 ____ inches (designate NO or NC position) 7 ____ inches (designate NO or NC position) Note: Allow at least 2 inches from fixed process connection to first switch location (up to 6 inches for slide connections), 3 inches between switch locations, and 2 inches from last switch location to bottom of probe. 3 Wire Color Diagrams and Table Below are wire color diagrams and a wire color table to assist you in wiring your FLR. L1 refers to the top-most level switch. Wire Colors For Four or Fewer Switches Black Black White White Red Red Green Green L1 L2 L3 L4 Wire Colors For Five or More Switches Black White Red Green Yellow Brown Blue Grey Common L1 L2 L3 L4 L5 L6 L7 Wire Color Table For Every Switch Configuration No. of Wiring Color Levels L1 L2 L3 L4 L5 L6 L7 Com. L1 Blk x 2 L2 Blk x 2 Wh x 2 L3 Blk x 2 Wh x 2 Red x 2 L4 Blk x 2 Wh x 2 Red x 2 Grn x 2 L5 Black White Red Green Yellow Grey L6 Black White Red Green Yellow Brown Grey L7 Black White Red Green Yellow Brown Blue Grey 4 CHAPTER 2: INSTALLATION AND REMOVAL PROCEDURES AND NOTES Tools Needed · Wrench sized appropriately for your FLR's mounting · Wrench sized appropriately for conduit connections · Thread tape or sealant compound for threaded connections Installation Notes · Do not locate the FLR series sensor near inlets/outlets. · If there is surface wave action, then use a time-delay relay or stilling tube. If a stilling tube is used, drill vent holes in the tube and use a spacer to assure the float has free travel inside the tube (See Figure 2.1). · The FLR can be mounted up to 30° from vertical. Inflow Stilling Tube Inflow 30° 30° Spacer 30° Figure 2.1 Mounting Instructions 1. Flange Mounting Provide the compatible mating flange on the tank and install using a suitable gasket. 2. Plug Mounting Provide the compatible female boss on the tank and install the FLR with a suitable gasket, O-ring, or thread tape. 5 Electrical Installation · Check the Wire Color Diagrams and Table on page 4 before making any connections. · Connect the wire(s) for each switch to your system. · Where neccessary, make junction box or conduit connection to 3/4" NPT threads above FLR mounting. · For inductive loads or high voltage/high current resistive loads, provide circuit protection for switch(es) (See Figure 2.2). See Specifications on page 2 for switch ratings. Protecting Circuit Using Diode Protecting Circuit Using Varistor Protecting Circuit Using CR E L R C Figure 2.2 C = 2I/10 (uF) R = Approx. 10 x I E (I + 50/E) MPORTANT: DO NOT EXCEED CONTACT RATINGS! A back electromotive force of several hundred volts (energy stored in the inductance) arises when the contacts are opened. under inductive loads or high/voltage/high current resisteive loads. This results in considerable decrease in contact life. Removal Instructions Removing your FLR from service must be done with care. · Ensure all switch ciruits are de-energized. · Disconnect all switch circuits. · Remove the FLR with an appropriately sized wrench (per your mounting type). · Clean the FLR's stem and floats of any debris (see General Care) and inspect for damage. · Store your FLR in a dry place, at a temperature between -40° and 100°C (-40° and 212°F). 6 CHAPTER 3: MAINTENANCE General Care Your FLR series stem-mounted multi-point float switch is very low maintenance and will need little care as long as it is installed correctly. However, in general, you should: · Periodically inspect the stem and floats for any trapped debris, sediment, or other foreign material. · Avoid applications for which the FLR was not designed, such as extreme temperatures, contact with incompatible corrosive chemicals, or other damaging environments. · If your FLR has an NPT mount, inspect the threads whenever you remove it from duty or change its location. IMPORTANT: The switch points on an FLR with no housing CANNOT be moved, changed, or adjusted. 7 Automation Products Group, Inc. Tel: 1 (888) 525-7300 or 1 (435) 753-7300 e-mail: sales@apgsensors.com www.apgsensors.com Automation Products Group, Inc. 1025 W. 1700 N. Logan, UT 84321