Installation Guide for AURORALIGHT models including: PTA725914 Maglio 18 Inch Pathlight, PTA725914, Maglio 18 Inch Pathlight, 18 Inch Pathlight, Pathlight

PTA725914 Install Guide

PTA725914 Maglio – Auroralight

PDF preview unavailable. Download the PDF instead.

MAGLIO PTA725914 INSTALL GUIDE
MAGLIO INSTALL GUIDE
PTA725914

INSTRUCTIONS: 1. To prevent electrical shock, disconnect transformer from
electrical supply and make sure power supply is completely off before installation. Fixtures should always be installed by a licensed electrician.
2. Pound the ground stake fully into soil, stake should be plumb.
3. Loosen the set screw with the supplied Allen key and remove the ½" adapter from the stem assembly. Screw the ½" adapter into the ground stake and tighten down by hand.
4. Feed the 18GA lead wires through the ground stake and out of lead wire exit hole (see figure).
5. Slide the stem assembly into the ½" adapter until it fully stops. Tighten the set screw down to secure in place.
6. Separate the 2-conductor 18GA lead wires by pulling apart the ends approximately 10". Strip about ½" of the insulation off the ends (see figure).
7. Connect the 18GA lead wires to 12GA underground supply cable using UL listed connectors suitable for underground burial or wet location (see figure for configuration).
8. Underground supply cable for power supply to this luminaire shall be SPT-3 Underground Low Energy Cable and listed as such (see figure).

FINISH GRADE WIRE EXIT HOLE UL LISTED WIRE CONNECTOR 12GA LISTED SPT-3 UNDERGROUND CABLE
18GA LEAD WIRE

REQUIRED TOOLS:
3/32 Allen Key (Included) Heavy Mallet/Hammer Wire Cutter / Stripper
STEM ASSEMBLY
SET SCREW 1/2" ADAPTER GROUND STAKE

P. 760.931.2910 E. techsupport@auroralight.com O. 2742 Loker Ave. W Carlsbad CA 92010 W. www.auroralight.com

TIP: Small gauge cable is vulnerable to damage in the landscape; Protect by routing in close proximity to the luminaire or adjacent to concrete slab or similar structure. Do not bury more than 6" deep. Do not over tighten.

WARNING: Luminaire must be
installed in accordance with local
codes and the National Electrical
Code (NEC). Failure to do so may result in serious injury and or damage to the luminaire.

WARNING: Risk of electric
shock. Install per NEC Code 680.22(B (6), if listed low voltage luminaires are to be
located near a pool, spa or fountain.

