134SAN Legacy™ Line Single-Stage Air Conditioner

with Puron Advance™ Refrigerant

1.5 To 5 Tons

Brand: Bryant

Product Data

This unit has been designed utilizing Bryant's non-ozone depleting, low global warming potential Puron Advance™ refrigerant. Air conditioners with Puron Advance™ refrigerant provide a collection of features unmatched by any other family of equipment.

NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (www.ahridirectory.org) for the most up-to-date ratings information.

Industry Leading Features / Benefits

Efficiency

  • 13.4 - 16.0 SEER2 / 11.0 – 13.5 EER2
  • Microtube Technology refrigeration system
  • Indoor air quality accessories available

Comfort

  • System supports programmable or standard thermostat controls

Reliability

  • Non-ozone depleting, low global warming potential Puron Advance™ refrigerant
  • Scroll compressor
  • Internal pressure relief valve
  • Internal thermal overload
  • Filter drier

Durability

Duraguard™ Protection Package:

  • Solid, durable sheet metal construction
  • Dense wire coil guard

Applications

  • Long-line – up to 250 feet (76.20 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.4 m) evaporator above condenser (See Long Line Guide for more information.)
  • Low ambient cooling (down to 0°F / -18°C ) with approved low ambient accessory kits.

Limited Warranty

  • 5-year parts limited warranty (including compressor and coil)
  • 10-year parts limited warranty (including compressor and coil) with timely registration*
  • Equipment must be registered within 90 days of original installation, except in jurisdictions where warranty benefits cannot be conditioned on registration.

* Applies to original purchaser/homeowner and not available to subsequent owners except in jurisdictions where applicable laws dictate otherwise.

See warranty certificate for complete details and restrictions.

Model Number Nomenclature

1234567,8,9101112
Product FamilyTier & RefrigerantSEER2OD Design TypeMajor SeriesVoltageCooling CapacityFeatureSpecial FeatureRegion
1=AC3 = Legacy Puron Advance™ (R-454B)4 = 13.4 SEER2S = Single StageA-Z=Major SeriesN = 208-230-1 or 208/230-1
P = 208-230-3 or 208/230-3
E= 460-3
018 = 18,000 BTUH (1.5 Tons)
024 = 24,000 BTUH (2 Tons)
030 = 30,000 BTUH (2.5 Tons)
036 = 36,000 BTUH (3 Tons)
042 = 42,000 BTUH (3.5 Tons)
048 = 48,000 BTUH (4 Tons)
060 = 60,000 BTUH (5 Tons)
0 = Standard
1=Compressor Electrical Rating Change
0 = StandardN = North AC

Catalog Ordering Numbers

Size Model Number
18134SAN01800N
24134SAN02400N
30134SAN03000N
36134SAN03600N
134SAP03600N
134SAE03600N
42134SAN04200N
48134SAN04801N
134SAP04800N
134SAE04800N
60134SAN06000N
134SAP06000N
134SAE06000N

Puron Advance™ logo and AHRI Certified™ Mark information are present but not transcribed as images.

UL and C-US logos are present but not transcribed.

Standard Features

Features18243036424860
Puron Advance™ RefrigerantXXXXXXX
SEER2 (Range depending on indoor combination)13.4-16.013.4-16.013.4-16.013.4-15.513.4-16.013.4-15.213.4-15.0
Scroll CompressorXXXXXXX
Factory Supplied, Field Installed Filter DrierXXXXXXX
Front Seating Service ValvesXXXXXXX
Internal Pressure Relief ValveXXXXXXX
Internal Thermal OverloadXXXXXXX
Long Line CapabilityXXXXXXX
Low Ambient Capability with KitXXXXXXX

Physical Data

UNIT SIZE18243036424860
COMPRESSOR TYPEScroll
REFRIGERANTPuron Advance™ (R-454B)
Factory Charge lb (kg)*3.90 (1.77)3.90 (1.77)5.30 (2.4)4.90 (2.22)6.60 (2.99)7.10 (3.22)6.40 (2.90)
COND FANForward Swept or Propeller Type, Direct Drive
Air DischargeVertical
Air Qty (CFM)1600210027002800380030004000
Motor HP1/121/101/101/101/41/51/4
Motor RPM11001100825825110011001100
COND COIL
Face Area (Sq ft)9.713.117.215.121.515.117.2
Fins per In.25252525252020
Rows1111122
Circuits4444668
VALVE CONNECT. (In. ID)
Vapor3/43/43/47/87/87/87/8
Liquid3/8"
REFRIGERANT TUBES* (In. OD)
Rated Vapor†5/83/43/47/87/87/81 1/8
Rated Liquid Line‡3/8"

*.For 15 ft. lineset. Adjust per installation instructions. Refrigerant charge varies with indoor unit; refer to refrigerant charge label.

†.Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset.

‡.See Liquid Line Sizing For Cooling Only Systems with Puron Advance™ Refrigerant tables.

Note: See unit Installation Instruction for proper installation.

Refrigerant Piping Length Limitations

Liquid Line Sizing and Maximum Total Equivalent Lengths for Cooling Only Systems with Puron Advance™ Refrigerant:

The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units.

See Table below for liquid line sizing and maximum lengths :

Table 1 - Maximum Total Equivalent Length: Outdoor Unit BELOW Indoor Unit

Size Liquid Line Connection Liquid Line Diam. (in.) w/ TXV AC with Puron Advance™ Refrigerant Maximum Total Equivalent Length*: Outdoor unit BELOW Indoor Vertical Separation ft (m)
0-5 (0-1.5)6-10 (1.8-3.0)11-20 (3.4-6.1)21-30 (6.4-9.1)31-40 (9.4-12.2)41-50 (12.5-15.2)51-60 (15.5-18.3)61-70 (18.6-21.3)71-80 (21.6-24.4)
180001/43/815015012510010075---
3/85/16250250250250250250250225150
3/8250250250250250250250250250
240001/47575755050----
3/85/16250250250250250225175125100
3/8250250250250250250250250250
300001/430--------
3/85/1617522520017512510075--
3/8250250250250250250250250250
360005/1617515015010010010075--
3/83/8250250250250250250250250250
420005/16125100100757550---
3/83/8250250250250250250250250150
480003/83/8250250250250250250230160-
600003/83/8250250250225190150110--

*.Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. -- = Outside acceptable range

Table 2 - Maximum Total Equivalent Length: Outdoor Unit ABOVE Indoor Unit

Size Liquid Line Connection Liquid Line Diam. (in.) w/ TXV AC with Puron Advance™ Refrigerant Maximum Total Equivalent Length*: Outdoor unit ABOVE Indoor Vertical Separation ft (m)
25 (7.6)26-50 (7.9-15.2)51-75 (15.5-22.9)76-100 (23.2-30.5)101-125 (30.8-38.1)126-150 (38.4-45.7)151-175 (46.0-53.3)176-200 (53.6-61.0)
180003/81/4175250250250250250250250
5/16250250250250250250250250
3/8250250250250250250250250
240003/81/4100125175200225250250250
5/16250250250250250250250250
3/8250250250250250250250250
300003/81/430-------
5/16250250250250250250250250
3/8250250250250250250250250
360003/85/16225250250250250250250250
3/8250250250250250250250250
420003/85/16175200250250250250250250
3/8250250250250250250250250
480003/83/8250250250250250250250250
600003/83/8250250250250250250250250

*.Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. -- = Outside acceptable range

Refrigerant Charge Adjustments

Table 3 - Refrigerant Charge Adjustments

Liquid Line SizePuron Advance™ Charge oz/ft (g/m)
3/80.60 (17.74) (Factory charge for lineset = 9 oz / 266.16 g)
5/160.40 (11.83)
1/40.27 (7.98)

Units are factory charged for 15 ft (4.6 m) of 3/8" liquid line. The factory charge for 3/8" lineset 9 oz. (266.16 g). When using other length or diameter liquid lines, charge adjustments are required per the chart above.

Charging Formula:

[(Lineset oz/ft X total length) – (factory charge for lineset)] = charge adjustment

Example 1:

System has 15 ft of lineset* using existing 1/4" liquid line. What charge adjustment is required?

Formula:(.27 oz/ft X 15ft) – (9 oz) = (-4.95) oz. Net result is to remove 4.95 oz of refrigerant from the system

Example 2:

System has 45 ft of existing 5/16" liquid line. What is the charge adjustment?

Formula:(.40 oz/ft. X 45ft) – (9 oz.) = 9 oz. Net result is to add 9 oz of refrigerant to the system

NOTE: Conditions must be favorable for charging by subcooling method. Indoor temperature must be 70°F to 80°F (21°C to 27°C), and outdoor temperature must be 70°F to 100°F (21°C to 38°C). If outside these conditions, adjust charge for long linesets by weigh-in method.

* When applicable. Refer to Physical Data Table in this PD and to the Installation Instructions for more information.

Long Line Applications

An application is considered "Long Line" when the total equivalent tubing length exceeds 80 ft or when there is more than 35 ft. vertical separation between indoor and outdoor units. These applications require additional accessories and system modifications for reliable system operation. The maximum allowable total equivalent length is 250 ft. The maximum vertical separation is 200 ft. when outdoor unit is above indoor unit, and 80 ft. when the outdoor unit is below the indoor unit. Refer to Accessory Usage Guideline below for required accessories. See Long-Line Application Guideline for required piping and system modifications. Also, refer to table below for acceptable vapor tube diameters to minimize the cooling capacity loss.

VAPOR LINE SIZING AND COOLING CAPACITY LOSS

Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for AC systems with Puron Advance™ refrigerant:

Table 4 - Vapor Line Sizing and Cooling Capacity Losses - Puron Advance™ Refrigerant 1-Stage Air Conditioner Applications

Unit Nominal Size (Btuh) Maximum Liquid Line Diameters (In. OD) Acceptable Vapor Line Diameters (In. OD) Cooling Capacity Loss (%) Total Equivalent Line Length ft. (m)
Standard Application Long Line Application Requires Accessories
26-50 (7.9-15.2)51-80 (15.5-24.4)81-100 (24.7-30.5)101-125 (30.8-38.1)126-150 (38.4-45.7)151-175 (46.0-53.3)176-200 (53.6-61.0)201-225 (61.3-68.6)226-250 (68.9-76.2)
181/25/825681012131516
3/83/4123445677
243/85/81345678910
3/4112334455
7/8012223344
303/85/8245689101113
3/4122344566
7/8112223344
363/85/82467910121314
3/4123345667
7/8112233445
423/83/4133456789
7/8122334456
1 1/8011122233
483/83/413456891011
7/8122344566
1 1/8011122233
603/83/42457810111214
7/8123456678
1 1/8000111223

Applications in this area may be long line and may have height restrictions. See the Residential Piping and Long Line Guideline.

Accessories

KIT NUMBERKIT NAME18243036424860
KSAFT0101AAAFRZ THERM KITXXXXXXX
KAATD0101TDRTIME DELAY KIT (90 second TDR)XXXXXXX
KAATD0201TDRTIME DELAY KIT (30 second TDR)XXXXXXX
KSALA0301410LOW AMBIENT COOLING KITXXXXXXX
KSALA1001AAAMOTORMASTER KITXXXXXXX
KSAHS2501AAAHARD START KIT (208-230-1 units only)XXXXXXX
KSAHS2701AAA*HARD START KITXX
KSACY0201AAACYCLE PROTR KITXXXXXXX
KSASF0201AAASPRT FEET KITXXXXXXX
KAALS0201LLS†SOL VALVE KITXXXXXXX
KAAWS0101AAAWINTER ST KITXXXXXXX
KAALP0501PURLOW PRESSURE SW KITXXXXXXX
KAAHI0601PURHIGH PRESSURE SW KITXXXXXXX
KAACH1701AAACRKC HTR KITXXXX
KAACH1601AAACRKC HTR KITXXX
KAACH2901AAACRKC HTR KIT (for 460-3 units only)XXX
KSASH2301COPSOUND BLKT KITXXXX
KSASH2401COPSOUND BLKT KITXXXX

*. Only use on models that have a "C" in position 15 of the 16 digit model number.

†. Do not use hard shutoff TXV with liquid solenoid valve

Accessory Usage Guideline

ACCESSORYREQUIRED FOR LOW-AMBIENT COOLING APPLICATIONS (Below 55°F/12.8°C)REQUIRED FOR LONG LINE APPLICATIONS*REQUIRED FOR SEA COAST APPLICATIONS (Within 2 miles/3.22 km)
Ball Bearing Fan MotorStandardStandardStandard
Compressor Start Assist Capacitor and RelayYesYesNo
Crankcase HeaterYesYesNo
Evaporator Freeze ThermostatYesNoNo
Hard Shut-Off TXVYesYesYes
Liquid Line Solenoid ValveNoNoNo
MotorMaster® Control or Low-Ambient Pressure SwitchYesNoNo
Support FeetRecommendedNoRecommended
Winter Start ControlYes†NoNo

*. For tubing set lengths between 80 and 200 ft. (24 and 61 m) horizontal or 35 ft. (10.7 m) vertical differential (total equivalent length), refer to the Residential Split-System Long Line Application Guideline.

†. Required if Low Pressure Switch is factory or field installed.

Accessory Description and Usage

  1. Ball-Bearing Fan Motor
    A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.
    Usage Guideline: Required on all units when MotorMaster® is used.
  2. Compressor Start Assist - Capacitor and Relay
    Start capacitor and relay gives a "hard" boost to compressor motor at each start up.
    Usage Guideline: Required for single-phase scroll compressors in the following applications: Long line, Low ambient cooling. Suggested for all single-phase compressors in areas with a history of low voltage problems.
  3. Crankcase Heater
    An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging.
    Usage Guideline: Required in low ambient cooling applications. Required in long line applications. Suggested in all commercial applications.
  4. Cycle Protector
    The cycle protector is designed to prevent compressor short cycling. This control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason, including power outage, protector control trip, thermostat jiggling, or normal cycling.
  5. Evaporator Freeze Thermostat
    An SPST temperature-actuated switch that stops unit operation when evaporator reaches freeze-up conditions.
    Usage Guideline: Required when low ambient kit has been added.
  6. Low-Ambient Pressure Switch Kit
    A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low-ambient temperatures down to 0°F (-18°C) when properly installed and also using wind baffles. Instructions provided in accessory kit.
    Usage Guideline: A Low-Ambient Pressure Switch or MotorMaster® Low-Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55°F (12.8°C).
  7. MotorMaster® Low-Ambient Controller
    A fan-speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to -10°F/-23.3°C), it maintains condensing temperature at 100°F ±10°F (37.8°C ±5.5°C).
    Usage Guideline: A MotorMaster® Low Ambient Controller or Low-Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55°F (12.8°C). Suggested for all commercial applications.
  8. Sound Blanket
    Wraparound sound reducing cover for the compressor. Reduces the sound level of the compressor.
    Usage Guideline: Suggested when unit is installed closer than 15 ft (4.57 m) to quiet areas, bedrooms, etc. Suggested when unit is installed between two houses less than 10 ft (3 m) apart.
  9. Support Feet
    Four or five stick-on plastic feet that raise the unit 4 in. (101.6 mm) above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing corrosion.
    Usage Guideline: Suggested in the following applications: Coastal installations. Windy areas or where debris is normally circulating. Rooftop installations. For improved sound ratings.
  10. Time-Delay Relay
    An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off.
    NOTE: Most indoor unit controls include this feature. For those that do not, use the guideline below.
    Usage Guideline: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to AHRI Directory of Certified Product Performance (AHRI Directory). When a Time-Delay Relay (TDR) is called for in the AHRI Directory, use a 30 second TDR for MicroChannel Indoor units and use a 90 second TDR for Round Tube Plate Fin Indoor units.
  11. Winter Start Control
    This control is designed to alleviate nuisance opening of the low-pressure switch by bypassing it for the first 3 minutes of operation.

AHRI RATINGS

NOTE: Ratings contained in this document are subject to change at any time.

For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org. Additional ratings and system combinations can be accessed via the Ratings Database here: MyBryantRatings

ELECTRICAL DATA

UNIT SIZEV/PHOPER VOLTS MAXMINCOMPR LRARLAFAN FLAMCAMAX FUSE or CKT BRK AMPS
1841.58.30.410.815
2459.08.20.612.120
3067.012.50.616.225
36208/230-125319782.513.50.617.530
42109.014.71.419.830
48126.018.11.223.840
60157.023.71.531.150
36208/230-325319797.812.80.616.625
48120.412.71.117.025
60156.417.71.523.635
36460-350641444.35.10.36.715
4850.06.40.58.515
6069.07.50.810.215

FLA- Full Load Amps, LRA - Locked Rotor Amps, MCA- Minimum Circuit Amps, RLA- Rated Load Amps

NOTE: Control circuit is 24V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection.

Sound Data

A-Weighted Sound Power (dBA) without Sound Shield

UNIT SIZESTANDARD RATING1252505001000200040008000
187266666666626055
247472687170656157
307267686868636054
367468696969656261
427471717070656259
487873767473686664
607473737170646259

A-Weighted Sound Power (dBA) with Accessory Sound Shield

UNIT SIZESTANDARD RATING1252505001000200040008000
187068666665615853
247474687171656056
307168676867625952
367168686867625957
427372717069646056
487776757372676462
607375747169636056

NOTE: Tested in compliance with AHRI 270 but not listed with AHRI.

Charging Subcooling (TXV-Type Expansion Device)

UNIT SIZEREQUIRED SUBCOOLING (F)Indoor
188TXV
2410
309
368
428
4812
6010

DIMENSIONS

UNITSERIESELECTRICAL CHARACTERISTICSABCDEFGHJKOPERATING WEIGHTSHIPPING WEIGHTSHIPPING LENGTH / WIDTH (Sq.)SHIPPING HEIGHT
INCHMMINCHMMINCHMMINCHMMINCHMMINCHMMINCHMMINCHMMLbsKgLbsKgINCHMMINCHMM
134SA*018*0NAY N N N23 1/8587.328 11/16728.73/419.16 9/16166.17 13/16197.911279.410 3/4273.113330.210949.412958.524 1/8612.731 1/16788.9
134SA*024*0NAY N N N25 3/4654.032 1/16815.13/419.16 9/16166.19 1/8231.315 3/4400.112 1/2317.512054.414063.526 3/4679.934 7/16875.2
134SA*030*ONAY N N N31 3/16792.532 1/16815.13/419.16 9/16166.19 1/8231.315 1/4387.413330.213963.016775.732 3/16817.934 7/16875.2
134SA*036*0NAY Y Y N31 3/16792.528 11/16728.77/822.26 9/16166.19 1/8231.315 1/4387.412 1/2317.513460.816273.532 3/16817.931 1/16788.9
134SA*042*0NAY N N N31 3/16792.538 7/8987.87/822.26 9/16166.124 11/16626.39 1/8231.316 3/4425.513330.217378.220190.932 3/16817.941 1/41048.0
134SA*048*1NAY Y Y N31 3/16792.528 11/16728.77/822.26 9/16166.124 11/16626.39 1/8231.315 3/4400.113330.217478.920090.732 3/16817.931 1/16788.9
134SA*060*ONAY Y Y N31 3/16792.532 1/16815.17/822.26 9/16166.124 11/16626.39 1/8231.316406.422558.818483.521195.532 3/16817.934 7/16875.2

NOTES:

  • 1. CENTER OF GRAVITY
  • Diagrams showing unit views and connection points are present but not transcribed as images.
UNIT SIZEMINIMUM GROUND MOUNTING PAD APPLICATION DIMENSIONSMINIMUM ROOF-TOP MOUNTING PAD APPLICATION DIMENSIONS
INCHMMINCHMM
1823 1/8587.317 7/8454.6
2425 3/4654.020 7/16518.5
30,36,42,48,6031 3/16792.522 15/16583.2
3526 3/4679.7

NOTE: ALL DIMENSIONS IN INCH (MM)

U.S. ECCN: Not Subject to Regulation (N.S.R.)

CLEARANCES

Clearances (various examples) diagram is described textually below:

  • Diagram shows wall configurations with required clearances around an air conditioner unit.
  • Example 1 (Two units against a wall): 6" (152.4 mm) service clearance on one side, 24" (609.6 mm) service clearance on the other side, 12" (304.8 mm) clearance on the front and back.
  • Example 2 (Three units against a wall): 24" (609.6 mm) service clearance on each side, 18" (457.2 mm) clearance on the front and back, 12" (304.8 mm) clearance on the sides.
  • Note: Numbers in () = mm
  • Allow 48" above unit.

IMPORTANT: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure there is adequate ventilation to prevent re-circulation of discharge air.

DETAILED COOLING CAPACITIES

134SAN01800N Outdoor Section With CVAVA1917XM* Indoor Section

CFMEWBCapacity MBtuh TotalSensTotal Sys. kW**Capacity MBtuh TotalSensTotal Sys. kW**Capacity MBtuh TotalSensTotal System kW**Capacity MBtuh TotalSensTotal System kW**Capacity MBtuh TotalSensTotal Sys. kW**Capacity MBtuh TotalSensTotal Sys. kW**
75 (23.9)85 (29.4)95 (35)105 (40.6)115 (46.1)125 (51.7)
52572 (22.2)20.1810.21.0219.499.921.1418.719.61.2717.899.271.4216.928.861.5915.828.41.79
67 (19.4)18.612.51.0318.0012.191.1517.1911.841.2716.411.491.4215.4811.051.5914.4610.61.79
63 (17.2)17.2712.041.0316.5811.681.1515.8911.351.2815.110.951.4214.2510.541.5913.2510.041.79
62 (16.7)17.0514.721.0316.4314.41.1515.714.061.2814.9313.641.4214.0913.241.5913.1112.821.78
57 (13.9)16.4316.431.0315.915.91.1515.3415.341.2814.6914.691.4213.9713.971.5913.1913.191.78
87572 (22.2)20.7810.771.0620.0610.481.1819.2510.151.3218.379.791.4716.228.921.8414.811.531.83
67 (19.4)19.1613.481.0718.4613.171.1917.712.841.3216.8412.441.4715.912.041.8313.5810.871.83
63 (17.2)17.8112.951.0817.1112.621.1916.3612.231.3215.5511.861.4714.6311.41.8313.9210.871.83
62 (16.7)17.616.21.0816.8615.941.1916.2115.591.3215.5915.591.4714.8114.811.8313.9213.921.83
57 (13.9)17.4217.421.0816.8616.861.1916.2716.271.3215.5715.571.4714.7914.791.8313.9113.911.83
95072 (22.2)20.910.91.0720.1510.591.1919.3510.281.3318.459.911.4816.39.041.8514.8811.761.85
67 (19.4)19.2713.711.0818.5613.411.1917.7913.071.3316.9312.681.4814.8811.531.8513.6411.081.85
63 (17.2)17.9113.161.0917.1912.81.216.4512.451.3415.6412.071.4813.6411.081.8514.0914.091.85
62 (16.7)17.716.561.0917.0316.281.216.2516.251.3315.7815.781.4814.9914.991.8514.0914.091.85
57 (13.9)17.6517.651.0917.0817.081.216.4316.431.3315.7615.761.4814.9714.971.8514.0814.081.85
112572 (22.2)20.910.91.0720.1510.591.1919.3510.281.3318.459.911.4816.39.041.8514.8811.761.85
67 (19.4)19.2713.711.0818.5613.411.1917.7913.071.3316.9312.681.4814.8811.531.8513.6411.081.85
63 (17.2)17.9113.161.0917.1912.81.216.4512.451.3415.6412.071.4813.6411.081.8514.0914.091.85
62 (16.7)17.716.561.0917.0316.281.216.2516.251.3315.7815.781.4814.9914.991.8514.0914.091.85
57 (13.9)17.6517.651.0917.0817.081.216.4316.431.3315.7615.761.4814.9714.971.8514.0814.081.85
140072 (22.2)27.2913.21.3526.1512.741.5224.9212.271.723.6311.771.8922.2811.252.120.9210.742.35
67 (19.4)24.9916.021.3723.9415.541.5322.815.031.721.6114.521.8920.3814.092.1119.0813.392.34
63 (17.2)23.1815.471.3922.1914.981.5421.1414.491.720.0213.971.8918.513.422.117.6512.862.34
62 (16.7)22.8118.721.3921.8618.251.5420.3217.751.719.6917.181.8918.4616.582.0917.4216.152.33
57 (13.9)21.9421.941.3921.1521.151.5420.3220.321.719.4219.421.8918.4318.432.0917.4917.492.34
130072 (22.2)27.8313.631.3926.6413.171.5625.3612.681.7323.9912.161.9322.6411.642.1521.1711.082.39
67 (19.4)25.4816.721.4124.416.251.5723.2215.741.7421.9815.231.9320.7214.672.1519.3514.12.38
63 (17.2)23.6516.121.4222.5515.661.5821.5515.151.7520.3714.611.9319.1714.172.1517.8513.432.36
62 (16.7)23.2919.761.4222.319.281.5821.218.751.7520.0518.231.9319.7217.52.1518.0318.032.38
57 (13.9)22.7322.731.4321.9421.941.5821.0521.051.7520.0520.051.9319.0319.032.1518.0518.052.38
140072 (22.2)28.2314.011.4227.0213.531.5925.6913.051.7724.2812.531.9722.8311.962.1921.3911.452.43
67 (19.4)25.8717.381.4424.7516.911.6123.5316.41.7822.2415.871.9720.6215.32.1919.5314.712.42
63 (17.2)24.0416.761.462316.281.6121.8515.761.7820.6215.21.9718.614.062.2118.0814.062.42
62 (16.7)23.6720.731.4622.6420.261.6221.5119.751.7820.5119.391.9719.5919.592.2118.4818.482.42
57 (13.9)23.4323.431.4622.5822.581.6221.6421.641.7820.620.61.9719.5519.552.2118.4618.462.42

134SAN02400N Outdoor Section With CVAVA2414XM* Indoor Section

CFMEWBCapacity MBtuh TotalSensTotal Sys. kW**Capacity MBtuh TotalSensTotal Sys. kW**Capacity MBtuh TotalSensTotal System kW**Capacity MBtuh TotalSensTotal System kW**Capacity MBtuh TotalSensTotal Sys. kW**Capacity MBtuh TotalSensTotal Sys. kW**
75 (23.9)85 (29.4)95 (35)105 (40.6)115 (46.1)125 (51.7)
120072 (22.2)47.7523.972.4545.9323.242.744.0122.472.9941.9521.653.3239.7720.83.6937.3819.874.11
67 (19.4)43.39292.4441.7428.252.74027.462.9938.1426.633.3136.0625.723.933.9724.824.09
63 (17.2)40.0927.952.4438.5327.182.6936.9226.42.9835.1625.593.3133.3424.723.6731.3323.754.07
62 (16.7)39.3833.912.4437.8733.162.6936.2832.372.9834.5931.543.332.7530.653.6730.7929.824.09
57 (13.9)37.9937.992.4436.836.82.6935.5435.542.9834.1434.143.332.6632.663.6731314.09
157572 (22.2)48.9724.972.5347.0324.22.7844.9723.393.0842.8422.553.4140.5221.663.783820.74.2
67 (19.4)44.530.592.5342.7429.812.7840.9293.0738.9528.193.3934.0127.213.7834.5326.254.18
63 (17.2)41.0929.412.5239.4628.632.7837.7527.823.0635.826.913.3734.1226.113.6432.2225.283.92
62 (16.7)40.3836.162.5238.7735.382.7737.0934.573.0635.3333.743.3833.3832.863.7632.1732.174.18
57 (13.9)39.7139.712.5238.4238.422.7737.0637.063.0635.5335.533.3933.933.93.7632.2232.224.17
180072 (22.2)49.7925.752.647.7524.962.8645.6424.143.1543.4123.273.4840.9922.353.8638.4321.394.27
67 (19.4)45.2631.92.643.4231.112.8541.530.283.1439.4329.373.4737.2428.453.8434.9127.484.25
63 (17.2)41.830.632.640.0929.832.8538.3129.013.1436.3628.113.4734.3727.23.8432.1826.214.24
62 (16.7)41.0638.032.5939.4137.292.8537.6736.483.1435.8835.973.4634.8534.853.8432.9532.954.25
57 (13.9)40.9540.952.5939.5839.582.8538.138.13.1436.5436.543.4634.8834.883.8332.9132.914.26
140072 (22.2)56.427.572.8854.0826.713.1951.5325.783.5448.7224.763.9445.623.654.3942.1822.444.9
67 (19.4)51.433.882.8649.3233.013.164732.053.5144.4631.023.941.6129.874.3538.4628.634.86
63 (17.2)47.6432.662.8545.7131.83.1443.5830.853.4841.2229.813.8738.5828.674.3235.6427.414.83
62 (16.7)46.7539.992.8544.8539.113.1442.7638.173.4840.4437.143.8738.4838.484.3236.0436.044.83
57 (13.9)45.6545.652.8444.1444.143.1342.4642.463.4840.5840.583.8738.438.44.3236.0236.024.83
157572 (22.2)57.4928.72.9755.0727.823.2852.3826.863.6349.4525.824.0446.2524.684.4842.6923.444.99
67 (19.4)52.4335.712.9550.2334.823.2547.833.843.645.1432.78442.1831.574.4438.8930.314.95
63 (17.2)48.6234.372.9446.5833.483.2344.3432.53.5741.8731.443.9739.1230.254.4136.0828.934.92
62 (16.7)47.6942.562.9345.6941.683.2343.5640.853.5742.0842.083.9739.7639.764.4237.1737.174.93
57 (13.9)47.4847.482.9345.8545.853.2344.0544.053.5742.0342.033.9739.7239.724.4237.1337.134.93
160072 (22.2)58.3229.723.0655.7928.823.3753.0227.853.7349.9826.784.1346.6825.624.5843.0124.355.08
67 (19.4)53.1937.423.0450.936.53.3448.3835.513.6945.6134.434.0942.5533.244.5339.2331.955.04
63 (17.2)49.3435.953.0247.2135.033.3244.8934.043.6642.3232.954.0639.4731.754.536.3230.455.01
62 (16.7)48.4445.13.0246.2446.243.3245.3745.373.6743.2143.214.0640.7740.774.5238.0638.065.03
57 (13.9)48.9848.983.0247.2547.253.3245.3245.323.6743.1643.164.0640.7240.724.5238.0438.045.03

134SA*06000N Outdoor Section With CVAVA6124XM* Indoor Section

CFMEWBCapacity MBtuh TotalSensTotal Sys. kW**Capacity MBtuh TotalSensTotal Sys. kW**Capacity MBtuh TotalSensTotal System kW**Capacity MBtuh TotalSensTotal System kW**Capacity MBtuh TotalSensTotal Sys. kW**Capacity MBtuh TotalSensTotal Sys. kW**
75 (23.9)85 (29.4)95 (35)105 (40.6)115 (46.1)125 (51.7)
180072 (22.2)69.3935.023.5866.5333.923.9563.4432.754.3760.1131.494.8656.530.145.452.628.686.02
67 (19.4)63.3943.133.5460.841.993.915840.744.3354.9639.454.8151.637.995.3548.0135.85.97
63 (17.2)58.8141.613.5256.4340.483.8853.8439.264.351.0137.954.7747.8636.465.3144.5635.045.94
62 (16.7)57.7150.843.5255.3849.713.8852.8448.534.2950.0347.174.7747.3946.795.3145.0145.015.95
57 (13.9)56.3856.383.5154.4954.493.8752.4452.444.2950.1750.174.7747.647.65.3144.8944.895.94
200072 (22.2)70.3936.13.6767.4234.974.0464.2233.764.4760.6732.434.9557.0131.065.4952.9329.586.11
67 (19.4)64.3444.843.6361.6543.67458.7442.424.4255.5441.054.8952.1839.655.4448.4738.096.06
63 (17.2)59.7343.213.6157.2542.043.9754.5640.814.3851.6439.464.8648.4538.075.444.9836.496.02
62 (16.7)58.653.263.656.1752.123.9653.5450.924.3851.5451.544.8648.9148.915.4146466.04
57 (13.9)58.0458.043.655.9355.933.9653.8953.894.3851.5151.514.8648.7648.765.4145.9345.936.03
225072 (22.2)71.3537.33.7868.2636.144.1564.9534.914.5861.3833.65.0657.5632.25.653.3430.656.22
67 (19.4)65.2646.833.7462.4645.644.1159.4344.374.5356.1642.995.0152.6241.55.5548.8140.016.17
63 (17.2)60.6245.063.7158.0343.874.0855.2342.614.4952.241.274.9748.939.755.5145.3238.256.13
62 (16.7)59.4556.113.7156.95554.0755.4755.474.552.9452.944.9850.1250.125.5347.0647.066.15
57 (13.9)59.8259.823.7157.7157.714.0855.4155.414.552.8852.884.9850.150.15.5247.0147.016.15

† Total and sensible capacities are net capacities. Blower motor heat has been subtracted.

Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80°F (27°C).

# Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240-2024. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur.

** System kw is total of indoor and outdoor unit kilowatts.

†† At TVA rating indoor condition (75°F edb/63°F ewb). All other indoor air temperatures are at 80°F edb.

NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.

EWB - Entering Wet Bulb

CONDENSER ONLY RATINGS

SST °F (°C)55.0 (12.8)65.0 (18.3)75.0 (23.9)85.0 (29.4)95.0 (35.0)105.0 (40.6)115.0 (46.1)
TCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKW
30.0 (-1.1)14.6971.670.6213.7381.130.7112.8790.700.812.07100.200.911.27109.731.0210.43119.401.169.53128.941.31
35.0 (1.7)16.1672.820.6215.1782.280.7114.2791.800.813.41101.410.9112.57110.911.0311.67120.461.1610.7129.841.32
40.0 (4.4)17.7174.030.6216.783.490.7115.7792.990.814.87102.570.9113.96112.051.0313121.551.1711.97130.881.32
45.0 (7.2)19.3675.250.6118.3384.720.717.3794.240.816.43103.710.9115.47113.241.0314.44122.711.1713.29131.271.32
50.0 (10.0)21.1276.540.620.0786.030.719.0895.530.818.1105.000.9117.08114.471.0415.98124.001.1814.8132.971.33
55.0 (12.8)22.9877.920.621.9287.400.6920.996.900.819.88106.350.9118.8115.761.0417.64125.251.1816.38134.211.34
TCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKW
30.0 (-1.1)19.6470.950.8418.9880.710.9718.0890.341.0917.0599.781.2315.94109.171.3714.74118.751.5413.58128.081.74
35.0 (1.7)21.7372.130.8320.9581.890.9619.9591.471.0918.81100.941.2317.62110.191.3816.37119.561.5515.03128.561.73
40.0 (4.4)23.9573.450.8223.0483.110.9521.9492.631.0920.69102.061.2319.38111.381.3918.06120.571.5516.64129.501.74
45.0 (7.2)26.3174.780.825.2884.390.9424.0493.901.0822.7103.211.2321.28112.491.3919.83121.761.5618.34130.521.75
50.0 (10.0)28.8176.190.7727.6385.790.9226.2895.151.0724.81104.421.2323.28113.631.3921.72122.851.5720.16131.911.77
55.0 (12.8)31.4677.570.7430.1487.080.928.6496.481.0627.05105.671.2225.4114.801.3923.72123.991.5822.04133.041.78

134SAN03000N Outdoor Section With CVAVA3117XM* Indoor Section

SST °F (°C)55.0 (12.8)65.0 (18.3)75.0 (23.9)85.0 (29.4)95.0 (35.0)105.0 (40.6)115.0 (46.1)
TCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKW
30.0 (-1.1)24.8670.650.9823.7380.171.1522.4889.661.3221.1799.051.4919.81108.411.6818.39117.821.8916.96127.122.14
35.0 (1.7)27.4471.880.9926.1881.421.1624.8390.811.3223.41100.141.521.92109.511.6920.39118.811.9118.85128.052.16
40.0 (4.4)30.273.220.9928.8382.671.1627.3692.041.3325.82101.321.5124.21110.641.7122.56119.881.9320.93128.912.18
45.0 (7.2)33.1774.73131.6884.101.1730.193.321.3528.42102.581.5326.67111.851.7324.89121.061.9623.09130.152.21
50.0 (10.0)36.3776.291.0234.7585.541.1933.0294.751.3631.21103.951.5529.32113.171.7527.39122.311.9825.44131.352.24
55.0 (12.8)39.8177.951.0338.0387.141.236.1596.351.3834.19105.451.5732.16114.561.7830.07123.622.0127.95132.622.28
TCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKW
30.0 (-1.1)27.5372.531.2226.4781.921.3925.2391.511.5723.86100.961.7722.41110.19220.77119.572.2719.07128.792.58
35.0 (1.7)30.4573.961.2229.2483.211.3927.8792.751.5826.4102.091.7824.81111.422.0123.11120.682.2821.29129.942.59
40.0 (4.4)33.6275.431.2332.2284.771.430.7194.091.5929.11103.431.7927.4112.702.0325.59121.912.2923.71130.972.6
45.0 (7.2)37.0476.931.2435.4586.321.4133.7895.671.632.03104.891.8130.18114.062.0428.26123.202.3126.24132.162.61
50.0 (10.0)40.7278.951.2538.9388.011.4237.0897.211.6135.17106.341.8233.17115.502.0631.09124.612.3328.92133.662.63
55.0 (12.8)44.6580.771.2542.6789.661.4340.6298.881.6338.52108.021.8436.36117.032.0734.12126.002.3431.81134.982.65

134SAN04200N Outdoor Section With CVAVA4217XM* Indoor Section

SST °F (°C)55.0 (12.8)65.0 (18.3)75.0 (23.9)85.0 (29.4)95.0 (35.0)105.0 (40.6)115.0 (46.1)
TCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKW
30.0 (-1.1)33.7570.601.5132.1580.121.730.5789.661.912999.112.1527.34108.672.4225.63118.122.7323.82127.453.06
35.0 (1.7)37.3271.841.5235.5781.261.733.8490.781.9132.13100.182.1530.36109.652.4328.46119.182.7426.54128.363.08
40.0 (4.4)41.1773.151.5239.2682.491.7137.3891.921.9235.5101.342.1633.57110.752.4431.54120.192.7529.48129.253.09
45.0 (7.2)45.2974.591.5243.283.941.7141.1693.221.9339.12102.532.1737.01111.942.4534.84121.222.7632.59130.353.11
50.0 (10.0)49.7176.091.5347.4585.271.7245.2394.521.9342.99103.842.1840.75112.942.4638.35122.442.7835.88131.613.13
55.0 (12.8)54.4877.651.545286.741.7249.5596.051.9447.12105.252.1944.65114.502.4842.09123.712.839.41132.833.15
TCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKW
30.0 (-1.1)39.2571.901.7837.3981.201.9735.5690.562.1933.7199.942.4631.67109.232.7829.44118.483.1626.99127.643.6
35.0 (1.7)43.1873.391.7941.2282.641.9839.2891.972.2137.26101.292.4835.09110.542.832.7119.723.1830.04128.793.61
40.0 (4.4)47.4475.011.7845.3584.211.9843.2593.452.2241.05102.692.538.73111.912.8236.14121.043.233.31130.083.64
45.0 (7.2)52.0376.761.7849.7885.891.9947.5395.092.2445.13104.242.5242.56113.372.8539.86122.473.2436.74131.403.67
50.0 (10.0)56.9578.621.7854.5487.71252.0796.832.2649.47105.922.5546.68114.962.8943.67123.943.2740.34132.773.7
55.0 (12.8)62.2680.701.7859.6589.742.0256.9398.732.2854.1107.732.5850.73116.552.9247.75125.503.3144.18134.263.75

134SA*06000N Outdoor Section With CVAVA6124XM* Indoor Section

SST °F (°C)55.0 (12.8)65.0 (18.3)75.0 (23.9)85.0 (29.4)95.0 (35.0)105.0 (40.6)115.0 (46.1)
TCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKWTCGSDTKW
30.0 (-1.1)48.0371.672.1546.1381.072.3944.0790.462.6841.8299.813.0239.32109.103.4136.59118.333.8633.58127.484.39
35.0 (1.7)53.1673.212.1551.0482.542.448.7891.872.746.32101.143.0343.63110.373.4340.65119.553.8837.56128.644.41
40.0 (4.4)58.6374.832.1656.2484.092.4253.7593.332.7251.08102.553.0648.19111.763.4545.01120.833.941.75129.934.43
45.0 (7.2)64.4276.612.1761.7685.742.445994.892.7456.07104.023.0953113.153.4949.66122.203.9546.11131.254.47
50.0 (10.0)70.578.452.1867.5687.482.4664.5296.552.7761.33105.613.1358114.663.5354.46123.653.9950.68132.584.52
55.0 (12.8)76.8780.412.2173.689.422.570.2998.372.8266.84107.303.1863.19116.243.5859.38125.144.0555.39134.014.58

KW- Outdoor Unit Kilowatts Only.

SDT-Saturated Temperature Leaving Compressor (°F)

SST-Saturated Temperature Entering Compressor (°F/°C)

TCG-Gross Cooling Capacity (1000 Btuh)

GUIDE SPECIFICATIONS

GENERAL

System Description

Outdoor-mounted, air-cooled, split-system air conditioner unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air-cooled coil, propeller-type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a packaged fan coil or coil unit.

Quality Assurance

  • Unit will be rated in accordance with the latest edition of AHRI Standard 210/240.
  • Unit will be certified for capacity and efficiency, and listed in AHRI directory.
  • Unit construction will comply with latest edition of ANSI/ ASHRAE and with NEC.
  • Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have c-UL-us approval.
  • Unit cabinet will be capable of withstanding Federal Test Method Standard No. 141 (Method 6061) 500-hr salt spray test.
  • Air-cooled condenser coils will be leak tested at 150 psig and pressure tested at 470 psig.
  • Unit constructed in ISO9001 approved facility.

Delivery, Storage, and Handling

  • Unit will be shipped as single package only and is stored and handled per unit manufacturer's recommendations.

Warranty (for inclusion by specifying engineer)

  • U.S. and Canada only.

PRODUCTS

Equipment

Factory assembled, single piece, air-cooled air conditioner unit. Contained within the unit enclosure is all factory wiring, piping, controls, compressor, refrigerant charge Puron Advance™ (R-454B), and special features required prior to field start-up.

Unit Cabinet

  • Unit cabinet will be constructed of galvanized steel, bonderized, and coated with a powder coat paint.
  • Available with dense grill only.

Fans

  • Condenser fan will be direct-drive propeller type, discharging air upward.
  • Condenser fan motors will be totally enclosed, 1-phase type with class B insulation and permanently lubricated bearings. Shafts will be corrosion resistant.
  • Fan blades will be statically and dynamically balanced.
  • Condenser fan openings will be equipped with coated steel wire safety guards.

Compressor

  • Compressor will be hermetically sealed.
  • Compressor will be mounted on rubber vibration isolators.

Condenser Coil

  • Condenser coil will be air cooled.
  • Coil will be constructed of aluminum fins mechanically bonded to copper or aluminum tubes which are then cleaned, dehydrated, and sealed.

Refrigeration Components

  • Refrigeration circuit components will include liquid-line shutoff valve with sweat connections, vapor-line shutoff valve with sweat connections, system charge of Puron Advance™ (R-454B) refrigerant, and compressor oil.
  • Unit will be shipped with filter drier for Puron Advance™ (R-454B) refrigerant.

Operating Characteristics

  • The capacity of the unit will meet or exceed Btuh at a suction temperature of °F/°C. The power consumption at full load will not exceed kW.
  • Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of Btuh or greater at conditions of CFM entering air temperature at the evaporator at °F/°C wet bulb and °F/°C dry bulb, and air entering the unit at °F/°C.
  • The system will have a SEER2 of Btuh/watt or greater at DOE conditions.

Electrical Requirements

  • Nominal unit electrical characteristics will be v, single phase, 60 Hz. The unit will be capable of satisfactory operation within voltage limits of v to V.
  • Nominal unit electrical characteristics will be v, three phase, 60 Hz. The unit will be capable of satisfactory operation within voltage limits of v to V.
  • Unit electrical power will be single point connection.
  • Control circuit will be 24v.

Special Features

  • Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements.

System Design Summary

  1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-IN W.C.
  2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F (12.8°C).
  3. Maximum outdoor operating air temperature is 115°F (46.1°C).
  4. For reliable operation, unit should be level in all horizontal planes.
  5. For interconnecting refrigerant tube lengths greater than 80 ft (23.4 m) and/or 35 ft (10.7 m) vertical differential, consult Residential Piping and Long Line Guideline and Service Manual available from equipment distributor.
  6. If any refrigerant tubing is buried, provide a 6 in. (152.4 mm) vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in. (914.4 mm) may be buried without further consideration. Do not bury refrigerant lines longer than 36 in. (914.4 mm).
  7. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
  8. Factory-supplied filter drier must be installed.
Models: 134SAN, 134SAN Legacy Line Single Stage Air Conditioner, Legacy Line Single Stage Air Conditioner, Line Single Stage Air Conditioner, Single Stage Air Conditioner, Air Conditioner

File Info : application/pdf, 22 Pages, 1.56MB

PDF preview unavailable. Download the PDF instead.

PDS134SAN-02

References

Adobe PDF Library 15.0

Related Documents

Preview Bryant 126S Series Air Conditioner Installation Instructions
Comprehensive installation guide for Bryant 126S Series Air Conditioners with Puron® Refrigerant (1-1/2 to 5 Nominal Tons). Covers safety, general installation, piping, electrical connections, and startup procedures for qualified personnel.
Preview Bryant 135SAN Legacy Line Single-Stage Air Conditioner Product Data
Product data and specifications for the Bryant 135SAN Legacy Line Single-Stage Air Conditioner with Puron Advance™ Refrigerant, covering capacities from 1.5 to 5 Tons. Includes efficiency ratings, comfort and reliability features, durability, applications, warranty information, model number nomenclature, standard features, physical data, refrigerant piping limitations, cooling capacities, and dimensions.
Preview Bryant 315S Legacy Line Air Conditioner Product Data
Detailed product data for the Bryant 315S Legacy Line Air Conditioner with Puron Refrigerant, covering features, specifications, ratings, and dimensions.
Preview Bryant 569L Legacy Line Condensing Units Product Data
Explore the product data for Bryant's 569L Legacy Line air conditioning condensing units, featuring Puron Advance™ (R-454B) refrigerant and Axion™ Fan Technology. This document details specifications, features, and performance data for units ranging from 6 to 25 nominal tons.
Preview Bryant 135SAN Legacy Line Air Conditioner Installation Instructions
Comprehensive installation guide for the Bryant 135SAN Legacy Line Air Conditioner with Puron Advance™ Refrigerant, covering safety, mounting, piping, electrical connections, start-up, and charging procedures.
Preview Bryant 113A Legacy Line 13 Air Conditioner - Product Data and Specifications
Comprehensive product data, features, specifications, and performance ratings for the Bryant 113A Legacy Line 13 Air Conditioner with Puron® Refrigerant, covering 1-1/2 to 5 nominal tons.
Preview Bryant FJ5 Legacy Series Fan Coil Product Data
Comprehensive product data for the Bryant FJ5 Legacy Series Fan Coil, featuring ECM motor technology, Puron Advance refrigerant compatibility, and various configurations for HVAC applications. Includes detailed specifications, performance data, and accessory information.
Preview Bryant FT5 Premium Fan Coil: InteliSense Technology, Variable Speed ECM, Puron Advance Refrigerant
Detailed product data for the Bryant FT5 Premium Fan Coil. Features InteliSense™ technology, variable speed ECM motor, Puron Advance™ refrigerant (R-454B), and advanced features for comfort, efficiency, and installation ease. Includes specifications, performance data, dimensions, and accessories.