Instruction Manual for CHECKLINE models including: ETPX, DTX, DTMX, KXE, MST, TS-232, MZ-232, MZ-USB, MZ-422, FS-232, FS-USB, FS-422, FSR-422, FS-WLAN, SCD-1, SC-PM, ETX Tension Meter, ETX, Tension Meter, Meter

Edition 02.0.D Tension Inspect 3 Instruction Manual - Checkline

6 1.3.2 Start and stop the tension value display Requirements: - Click on Clear data in the menu Datat. ings shown in the Tension display, if any, are cleared.All read

Tension Inspect Manual PDF File

Tension Inspect Software


File Info : application/pdf, 12 Pages, 3.24MB

PDF preview unavailable. Download the PDF instead.

TensionInspect3Manualv20WEB
Tension Meter

Model

ETX ETPX DTX DTMX KXE MST TS-232 MZ-232 MZ-USB MZ-422 FS-232 FS-USB FS-422 FSR-422 FS-WLAN SCD-1 SC-PM

®
Edition

02.0.D

»Tension Inspect 3« Instruction Manual

® Checkline · 175 Vincent Ave, Lynbrook, NY 11563 - USA www.Checkline.com · info@checkline.com · 516-295-4300

Contents 1 The »Tension Inspect 3« program .......................................................................... 3
1.1 System requirements ............................................................................................. 3 1.2 Installing »Tension Inspect 3«................................................................................ 3 1.3 Using »Tension Inspect 3«..................................................................................... 4
1.3.1 Basic settings .................................................................................................. 5 1.3.2 Start and stop the tension value display.......................................................... 6 1.3.3 Hi /Lo set-points ............................................................................................... 7 1.3.4 Graph adjustments .......................................................................................... 7 1.3.5 Print and data transfer..................................................................................... 8 1.3.6 Save and load the readings............................................................................. 8 1.3.7 Memory review ................................................................................................ 9
1.3.7.1 Download the tension data from the ETX, ETPX and DTX to the PC 10 1.3.7.2 Graph adjustments............................................................................. 10 1.3.7.3 Print and data transfer ....................................................................... 10 1.3.7.4 Save the readings .............................................................................. 11 1.3.8 Online recording ............................................................................................ 11 2 Correspondence ..................................................................................................... 11
2

1 The »Tension Inspect 3« program

1.1 System requirements

Computer:

PC

Operating system: Windows 7 and higher (32 / 64 Bit)

Hard disk space: Approx. 200 MB

Installation:

CD-ROM drive

1.2 Installing »Tension Inspect 3« To be able to restore the original files in case problems occur after the installation, you should make a backup of your hard disk contents before you start installing. In no event will Hans Schmidt & Co GmbH be held liable for any data loss or damage.
1. Insert the CD-ROM with the »Tension Inspect 3« program into the CD-ROM drive. 2. Start the installation process by double-clicking the application file.

3. Follow the instructions on the screen, to install the software »Tension Inspect 3« and the corresponding USB driver.
4. At the end, click the "Finish" button, to finish the installation process.
3

1.3 Using »Tension Inspect 3«

- Double-click the »Tension Inspect 3« TI3 icon to start the program.
The program window opens.

4 5 6 7 8 9 10

11 12 13 14 15 16

1 2 3

17

18 19 20

1 Menu file

Save as CSV

Menu file

Load CSV

Menu file

Exit

2 Button

Start/Stop

3 Choice box

Scale

4 Button

Start Rec.

5 Menu samplerate Samplerate

6 Button

Auto

7 Menu setup

Setup

8 Menu alarms

Enable Alarms

Menu alarms

Show Alarms

Menu alarms

Clear Alarms

9 Menu data

Clear Data

Menu data

Create HTML-Report

Menu data

Export Screen to Excel

Menu data

Memory Review

4

21
Chapter 1.3.6 Chapter 1.3.6 Close »Tension Inspect 3« Chapter 1.3.2 Chapter 1.3.4 Chapter 1.3.8 Select the sampling rate Chapter 1.3.4 Chapter 1.3.1 Chapter 1.3.3 Chapter 1.3.3 Chapter 1.3.3 Clear all measuring values Chapter 1.3.5 Chapter 1.3.5 Chapter 1.3.7

1.3 Using »Tension Inspect 3« (cont.) 10 Menu info 11 Display Alarms

12 Display 13 Button 14 Display 15 Display 16 Display 17 Display 18 Display 19 Display

Tension Reset Unit Statistics Model Timeshift Buffer Timeshift Statistics Diagram

20 Display Readings on Screen 21 Display Tension

Information about »Tension Inspect 3« Change to red, if the reading exceed or underrun the setpoint durring a measuring Current reading Chapter 1.3.4 Unit of measure of the readings Display of statistical values of the measurement Display the connected unit Chapter 1.3.4 Chapter 1.3.4 Display the statistical values, shown currently at the graph. Chapter 1.3.4 Readings as graph, as well as the Hi/Lo Set-points (only when activated)

1.3.1 Basic settings Requirements: - The required measuring unit is connected to the PC. - The measuring unit is switched on

To edit the settings: - Click on the menu SETUP to open the dialog box.
You can now either keep the default values preset in the input boxes or customize them for your specific requirements. The figure below shows the factory-preset defaults for a tension meter model ETX-500.

Enter text for the header For testing the connection between the describing the stored data PC and the connected tension meter

Select the tension meter model
Transfer speed of the serial interface

Select the tension range
Select the unit of measure.

Enter the COM Port (1-4) to which the tension meter is connected
Activates recording of the values which exceed or underrun the Hi/Lo set-points
Determine the file for saving data of online recording

Select the max. number of readings, displayed at the graph

Select the sample rate
Damping
Changing the background colour to black
Enter the Hi/Lo set-points
5

1.3.2 Start and stop the tension value display Requirements: - Click on Clear data in the menu Datat. All readings shown in the Tension display, if any, are cleared.

Start:

- Click the Start button to activate the display of tension values.

The button shows Stop.

Tension value display:

Tension display

Current graph, as well as high set-point (red) and

low set-point, if activated in the menu Alarms or

Setup

Tension display

Current digital value

Statistics display

Continuously updated statistics

Statistics Diagram display

Continuously updated statistics, of readings,

shown in the graph

Stop: - Click now the Stop button. The display of the tension values stops. The button shows Start.

6

1.3.3 Hi /Lo set-points »Tension Inspect 3« has a comparison function. Thereby the displayed value will be compared with the preset set-points. During exceeding or underrunning a set-point, the background of the display Tension change to red. The background of the display No Alarms change the colour permanently to red and shows now Alarms after exceeding or underrunning a setpoint for one time.

Enable Alarms Show Alarms

Activates recording of the values which exceed or underrun the Hi/Lo set-points By clicking Show Alarm at the menu Alarms the window ,,Alarm events" will be opend.

Clear Alarms

By opening the context menu in the window ,,Alarm events" the values exceeding or underrunning the set-points can be exported to excel by using the menu items ,,Export" and ,,Export data to excel".
By clicking Clear Alarms in the menu Alarms all values in the window ,,Alarm events" will be cleared.

1.3.4 Graph adjustments Scale
Auto
Reset Readings on Screen (Timescale)
Timeshift Buffer
Timeshift

The maximal tension value of the diagram can be adjusted (Y-axis, starts at zero). Automatic scaling of the Y-axis depending to the measured tension values. Change of scaling from mode Auto to Scale To set the number of readings to be shown in the diagram (X-axis). The scroll bar turns to red, if more readings are selected for the diagram than measured. Indicates in % the fill level of the memory. The maximal numbers of readings will be set in the Setup. To select the timeframe of a series of measurements, that should be displayed in the diagram. Is the setup Value of Readings on Screen bigger or equal to the recorded readings, the scroll bar cannot be moved.

7

1.3.5 Print and data transfer Print: - Click Creat HTML-Report in the menu Data to open the print preview. - Click the Print this Page button to open the printer setup box. The print-out includes the statistical data of the series of measurements, the current displayed graph and the statistical values of the graph.
Data transfer: - Clicking Export Screen to Excel in the menu Data copy the readings,
which are displayed at the graph to an excel file (reading, date, time). With the infixed readings, a graph can be created in the Excel file.
1.3.6 Save and load the readings Save: - The statistical data, as well as the single readings of a measuring can be saved after the measuring ends as CSV file, by clicking Save as CSV in the menu File. Load: - Click Load CSV in the menu File and open the required file. The statistical data of the saved measuring, the graph and the statistical data of the graph are displayed in »Tension Inspect 3«
It is possible to add readings to an existing file. In this case open the file and start a new series of measurements. The new readings will be added in the diagram. After this store the complete CSV file again. If any readings are in the internal memory before opening the existing file, the internal memory will be overwritten.
8

1.3.7 Memory review (available only for ETX, ETPX and DTX) With the »Tension Inspect 3« program you can download all the tension data stored in the memory of the connected tension meter. Start the download - Click Memory Review in the menu Data. The Memory Review window opens.

BCD E F G H I

J

A

K

L
A Button B Choice box C Button D Display E Choice box F Button G Display H Button I Display J Display K Display
L Button M Button N Display O Button P Button

M

N

Read Data Scale Autoscale Position in Memory Selected Position Reset Memory Mode Zoom Unit Type of Device Statistics

Save Generate Tension Export to Excel Close

O

P

Chapter 1.3.7.1 Chapter 1.3.7.2 Chapter 1.3.7.2 Number of saved series of measurement Selected series of measurement Chapter 1.3.7.2 Used memory mode during the measuring Chapter 1.3.7.2 measuring unit of the readings Display the connected unit Statistical data of the displayed series of measurement Chapter 1.3.7.4 Chapter 1.3.7.3 Readings as graph Chapter 1.3.7.3 Close Memory Review
9

1.3.7.1 Download the tension data from the ETX, ETPX and DTX to the PC Requirements: - Tension meter connected to the PC. - Tension meter switched on.
To download the tension data: - Click the Read Data button.
The tension data stored in the tension meter are read into the PC.
Tension value display: Display Tension Graph of the displayed series of measuremnts Display Statistics Statistical data of the displayed series of measurements

1.3.7.2 Graph adjustments

Scale

Manual scaling of the Y-axis which starts at ,,zero". This feature can be

activated by pressing Reset.

Autoscale Automatic scaling of the Y-axis depending to the displayed readings of

the diagram.

Reset

Activates the scaling, which is set in the pop-up Scale.

Zoom

A big number of zoom features can be selected to enlarge a selected

frame of the diagram.

The button Zoom and Reset work only if Autoscale is not activated.
1.3.7.3 Print and data transfer Print: - Click the Generate button to open the print review. - Click the Print this Page button to open the printer setup box.
The print-out includes the statistical data of the series of measurements and the current displayed graph.
Data transfer: - The Export Screen to Excel
button copies the readings of the desired series of measuremetns to an excel file (reading, date, time). With the infixed readings, a graph can be created in the Excel file.

10

1.3.7.4 Save the readings Save: - With the button Save stored values (statistics and series of measurements) of the connected tension meter can be downloaded and stored as CSV file. The individual series of measurement can be selected.
Readings which have be downladed and be stored as CSV file cannot be related to »Tension Inspect 3«

1.3.8

Online recording - Click first the button Start/Stop and afterwards Start/Stop Rec. to start the
continuously data recording. The recorded data is now saved as CSV file. If the file reaches a size of 10 MB, a new CSV file will be generated automatically for further data aquisition and saving. - By clicking the button Start/Stop the continuously data aquisition is paused. Clicking Start/Stop again will continue the recording. The data will be saved in the last CSV file. - By clicking the button Start/Stop Rec. the continuously data aquisition is finished. After clicking Start/Stop Rec. again the recorded data will be saved in a new CSV file. - The location for saving the files can be determined in the menu Setup.

2

Correspondence

Should you have any questions regarding the program or operating instructions, or

their use, please indicate above all the software version number.

11

®