Owner's Manual for MEAN WELL models including: MDR-60-24 60W Single Output Industrial DIN Rail Power Supply, MDR-60-24, 60W Single Output Industrial DIN Rail Power Supply, Output Industrial DIN Rail Power Supply, Industrial DIN Rail Power Supply, DIN Rail Power Supply, Rail Power Supply, Power Supply, Supply

MDR-60-20240219

wangj

MDR-60-24 MEAN WELL - РКС Компоненти - РАДІОМАГ


File Info : application/pdf, 2 Pages, 129.78KB

PDF preview unavailable. Download the PDF instead.

mdr-60-spec pdfjs
60W Single Output Industrial DIN Rail Power Supply

MDR-60 series

 GTIN CODE

 Features :
Universal AC input/Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 Class I, Div 2 Hazardous Locations T4 LED indicator for power on DC OK relay contact No load power consumption<0.75W 100% full load burn-in test 3 years warranty

User's Manual

MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION

UL62368-1

R33100 RoHS

TPTC004

THOMAS SAMUEL

THOMAS SAMUEL

IS13252

(except 48V)

Bauart gepruft Sicherheit
egelma ge od o s be wac g
www.tuv.com ID 2000000000

BS EN/EN62368-1 IEC62368-1

MODEL

MDR-60-5

MDR-60-12

MDR-60-24

MDR-60-48

DC VOLTAGE

5V

12V

24V

48V

RATED CURRENT

10A

5A

2.5A

1.25A

CURRENT RANGE

0 ~ 10A

0 ~ 5A

0 ~ 2.5A

0 ~ 1.25A

RATED POWER

50W

60W

60W

60W

OUTPUT

RIPPLE & NOISE (max.) Note.2 80mVp-p

VOLTAGE ADJ. RANGE

5 ~ 6V

VOLTAGE TOLERANCE Note.3 ±2.0%

LINE REGULATION

±1.0%

LOAD REGULATION

±1.5%

120mVp-p 12 ~ 15V ±1.0% ±1.0% ±1.0%

150mVp-p 24 ~ 30V ±1.0% ±1.0% ±1.0%

200mVp-p 48 ~ 56V ±1.0% ±1.0% ±1.0%

SETUP, RISE TIME Note.5 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load

HOLD UP TIME (Typ.)

50ms/230VAC 20ms/115VAC at full load

VOLTAGE RANGE

85 ~ 264VAC 120 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

78%

85%

87%

87%

INPUT

AC CURRENT (Typ.)

1.8A/115VAC 1A/230VAC

INRUSH CURRENT (Typ.) COLD START 30A/115VAC 60A/230VAC

LEAKAGE CURRENT

<1mA / 240VAC

OVERLOAD PROTECTION
OVER VOLTAGE

105 ~ 150% rated output power

Protection type : Constant current limiting, recovers automatically after fault condition is removed

6.25 ~ 7.25V

15.6 ~ 18V

31.2 ~ 36V

57.6 ~ 64.8V

Protection type : Shut down o/p voltage, re-power on to recover

FUNCTION DC OK SIGNAL WORKING TEMP. WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS

SAFETY & WITHSTAND VOLTAGE

EMC (Note 4)

ISOLATION RESISTANCE EMC EMISSION

EMC IMMUNITY

Relay contact rating(max.): 30V/1A resistive -20 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH ±0.03%/ (0 ~ 50) Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6 Ul508, UL62368-1, TUV BS EN/EN62368-1,Class I, Div. 2 Group A, B, C, D Hazardous Locations T4, EAC TP TC 004, BSMI CNS14336-1, AS/NZS 60950.1 , IS13252(Part1)/IEC60950-1(except 48V) approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438 Class B
Compliance to BS EN/EN61000-4-2, 3, 4, 5, 6, 8, 11, BS EN/EN55035, BS EN/EN61000-6-2, BS EN/EN61204-3, heavy industry level, EAC TP TC 020

OTHERS NOTE

MTBF

2355.2K hrs min. Telcordia SR-332 (Bellcore) ; 489.9K hrs min. MIL-HDBK-217F (25)

DIMENSION

40*90*100mm (W*H*D)

PACKING

0.33Kg; 42pcs/14.8Kg/0.82CUFT

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1F & 47F parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) 5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 6. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).  Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

File Name:MDR-60-SPEC 2024-02-19

Downloaded from Arrow.com.

60W Single Output Industrial DIN Rail Power Supply

Mechanical Specification
35

40 55555

+V +V -V -V DC OK
DC OK +
+V ADJ

MDR-60 series
Case No.962A Unit:mm
100

LOAD (%)
90
LOAD (%)

NL

Install DIN rail TS35/7.5 or TS35/15
Block Diagram

7.5 7.5

I/P

EMI FILTER

RECTIFIERS &
FILTER

FG

DC OK Relay Contact

Contact Close

PSU turns on / DC OK.

Contact Open

PSU turns off / DC Fail.

Contact Ratings (max.) 30V/1A resistive load.

Derating Curve

O.L.P.

POWER SWITCHING
CONTROL

RECTIFIERS &
FILTER

O.C.P.

DETECTION CIRCUIT

O.V.P.

Output Derating VS Input Voltage

fosc : 60KHz DC OK
+V -V

100

12V,24V,48V

80

60

50

5V

40

20

-20

0

10

20

30

45

55

60 70 (VERTICAL)

AMBIENT TEMPERATURE ()

100 90 80 70 60 50 40
85 95 100 115 120 140 160 180 200 220 240 264
INPUT VOLTAGE (VAC) 60Hz

File Name:MDR-60-SPEC 2024-02-19

Downloaded from Arrow.com.



References

Acrobat Distiller 9.0.0 (Windows); modified using iText 5.5.6 ©2000-2015 iText Group NV (AGPL-version) (AGPL-version)