User Guide for Edge-core models including: ECS4100 Series Ethernet Switch, ECS4100 Series, Ethernet Switch, Switch
ECS4100 Series Quick Start Guide-R04 – Edgecore Networks
File Info : application/pdf, 9 Pages, 777.64KB
DocumentDocumentQuick Start Guide ECS4100 Series Switch 1. Unpack the Switch and Check Contents ECS4100-12T ECS4100-12PH ECS4100-28TC ECS4100-28T ECS4100-28P ECS4100-52T ECS4100-52P Rack Mounting Kit--two brackets and eight screws Four adhesive foot pads Power Cord--either Japan, US, Continental Europe or UK Console Cable--RJ-45 to DB-9 Documentation--Quick Start Guide (this document) and Safety and Regulatory Information Note: The ECS4100 series switches are for indoor use only. Note: For safety and regulatory information, refer to the Safety and Regulatory Information document included with the switch. Note: Other documentation, including the Web Management Guide, and CLI Reference Guide, can be obtained from www.edge-core.com. 2. Mount the Switch 1 Caution: Installing the switch in a rack requires two people. One person should position the switch in the rack, while the other secures it using the rack screws. Attention: Deux personnes sont nécessaires pour installer un commutateur dans un bâti : La première personne va positionner le commutateur dans le bâti, la seconde va le fixer avec des vis de montage. Note: The switch can also be installed on a desktop or shelf using the included adhesive rubber foot pads. 3. Ground the Switch 1 2 1 Ensure the rack on which the switch is to be mounted is properly grounded and in compliance with ETSI ETS 300 253. Verify that there is a good electrical connection to the grounding point on the rack (no paint or isolating surface treatment). 2 Attach a lug (not provided) to a #18 AWG minimum grounding wire (not provided), and connect it to the grounding point on the switch using a 3.5 mm screw and washer. Then connect the other end of the wire to rack ground. Caution: The earth connection must not be removed unless all supply connections have been disconnected. Attention: Le raccordement à la terre ne doit pas être retiré sauf si toutes les connexions d'alimentation ont été débranchées. Caution: The device must be installed in a restrictedaccess location. It should have a separate protective earthing terminal on the chassis that must be permanently connected to earth to adequately ground the chassis and protect the operator from electrical hazards. Attention: L'appareil doit être installé dans un emplacement à accès restreint. Il doit comporter une borne de terre de protection distincte sur le châssis, qui doit être connectée en permanence à la terre pour assurer une mise à la terre adéquate du châssis et protéger l'opérateur des risques électriques. 2 1 Attach the brackets to the switch. 2 Use the screws and cage nuts supplied with the rack to secure the switch in the rack. 1 E042024-AP-R04 150200001807A 4. Connect AC Power 1 7. Connect Network Cables 1 Quick Start Guide 1 Plug the AC power cord into the socket on the rear of the switch. 2 Connect the other end of the power cord to an AC power source. Note: For International use, you may need to change the AC line cord. You must use a line cord set that has been approved for the socket type in your country. 5. Verify Switch Operation 1 1 Verify basic switch operation by checking the system LEDs. When operating normally, the Power and Diag LEDs should be on green. 6. Perform Initial Configuration 2 1 For RJ-45 ports, connect 100-ohm Category 5, 5e or better twisted-pair cable. 2 For the SFP/SFP+ slots, first install SFP/SFP+ transceivers and then connect fiber optic cabling to the transceiver ports. The following transceivers are supported: 1000BASE-SX (ET4202-SX) 1000BASE-LX (ET4202-LX) 1000BASE-RJ45 (ET4202-RJ45) 1000BASE-EX (ET4202-EX) 1000BASE-ZX (ET4202-ZX) 3 As connections are made, check the port status LEDs to be sure the links are valid. On/Blinking Green -- Port has a valid link. Blinking indicates network activity. On Amber -- Port is supplying PoE power. 1 2 3 1 Connect a PC to the switch console port using the included console cable. 2 Configure the PC's serial port: 115200 bps, 8 characters, no parity, one stop bit, 8 data bits, and no flow control. 3 Log in to the CLI using default settings: Username "admin" and password "admin." Note: For further information on switch configuration, refer to the Web Management Guide and CLI Reference Guide. 2 Hardware Specifications Switch Chassis Size (W x D x H) 12T: 18.0 x 16.5 x 3.7 cm (7.08 x 6.49 x 1.45 in) 12PH: 33.0 x 20.5 x 4.4 cm (12.9 x 8.07 x 1.73 in) 28T/52T: 44 x 22 x 4.4 cm (17.32 x 8.66 x 1.73 in) 28TC: 33 x 23 x 4.4 cm (12.30 x 9.06 x 1.73 in) 28P/52P: 44 x 33 x 4.4 cm (17.32 x 12.30 x 1.73 in) Weight 12T: 820 g (1.81 lb) 12PH: 2.38 kg (5.26 lb) 28T: 2.2 kg (4.85 lb) 28TC: 2 kg (4.41 lb) 28P: 3.96 kg (8.73 lb) 52T: 2.5 kg (5.5 lb) 52P: 4.4 kg (9.70 lb) Operating Temperature Storage Temperature All except below: 0°C to 50°C (32°F to 122°F) 28P/52P only: -5°C to 50°C (23°F to 122°F) 52T only: 0°C to 45°C (32°F to 113°F) 12PH@70 W only: 0°C to 55°C (32°F to 131°F) 12PH@125 W only: 5°C to 55°C (23°F to 131°F) 12PH@180 W only: 5°C to 50°C (23°F to 122°F) -40°C to 70°C (-40°F to 158°F) Operating All except below: 10% to 90% Humidity (noncondensing) 28P/52P only: 5% to 95% 12T/12PH only: 0% to 95% Power Specification AC Input Power 12T: 100-240 VAC, 50-60 Hz, 0.5 A 12PH: 100-240 VAC, 50/60 Hz, 4A 28T: 100-240 VAC, 50/60 Hz, 1 A 28TC:100-240 VAC, 50-60 Hz, 0.75 A 28P: 100-240 VAC, 50-60 Hz, 4 A 52T: 100-240 VAC, 50/60 Hz, 1 A 52P: 100-240 VAC, 50-60 Hz, 6 A Total Power Consumption 12T: 30 W 12PH: 230 W (with PoE function) 28T: 20 W 28TC: 20 W 28P: 260 W (with PoE function) 52T: 40 W 52P: 420 W (with PoE function) PoE Power Budget 12PH: 180 W 28P: 190 W 52P: 380 W Regulatory Compliances Emissions EN55032 Class A EN IEC 61000-3-2 Class A EN 61000-3-3 BSMI (CNS15936) FCC Class A VCCI Class A Immunity EN 55035 IEC 61000-4-2/3/4/5/6/8/11 Safety UL/CUL (UL 62368-1, CAN/CSA C22.2 No. 62368-1) CB (IEC 62368-1/EN 62368-1) BSMI (CNS15598-1) Quick Start Guide Taiwan RoHS TEC CNS15663 Certified ID 379401073 (ECS4100-12T only) 3 ECS4100 1. ECS4100-12T ECS4100-12PH ECS4100-28TC ECS4100-28T ECS4100-28P ECS4100-52T ECS4100-52P -- -- -- RJ-45 DB-9 -- EC4100 Web CLI www.edge-core.com 2. 1 2 3. 1 2 1 ETSI ETS 300 253 2 18 AWG 3.5mm 4. AC 1 1 2 1 2 4 5. 1 1 LED LED 6. 1 2 3 1 PC 2 PC 115200 bps 8 8 3 CLI "admin" "admin" Web CLI 7. 1 2 1 RJ-45 100-ohm Category 55e 2 SFP/SFP+ SFP/SFP+ 1000BASE-SX (ET4202-SX) 1000BASE-LX (ET4202-LX) 1000BASE-RJ45 (ET4202-RJ45) 1000BASE-EX (ET4202-EX) 1000BASE-ZX (ET4202-ZX) 3 LED / -- / PoE 5 (W x D x H) 12T18.0 x 16.5 x 3.7 cm 7.08 x 6.49 x 1.45 12PH33.0 x 20.5 x 4.4 cm 12.9 x 8.07 x 1.73 28T/52T44 x 22 x 4.4 cm 17.32 x 8.66 x 1.73 28TC33 x 23 x 4.4 cm 12.30 x 9.06 x 1.73 28P/52P44 x 33 x 4.4 cm 17.32 x 12.30 x 1.73 12T820 g 1.81 12PH2.38 kg 5.26 28T2.2 kg 4.85 28TC2.0 kg 4.85 28P3.96 kg 8.73 52T2.5 kg 5.5 52P4.4 kg 9.70 0°C ~ 50°C 32°F ~ 122°F -5°C ~ 50°C 23°F to 122°F, ECS4100-28P/52P 0°C ~ 45°C 32°F ~ 113°F, ECS4100-52T 0°C ~ 55°C 32°F ~ 131°F, ECS4100-12PH@70 W -5°C to 55°C 23°F to 131°F, ECS4100-12PH@125 W -5°C to 50°C 23°F to 122°F, ECS4100-12PH@180 W -40°C ~ 70°C -40°F ~ 158°F 5% to 95% , ECS410028P/52P 10% to 90% 0% 95% , ECS410012T ECS4100-12PH AC 12T: 100-240 , 50/60 Hz, 0.5 A 12PH: 100-240 , 50/60 Hz, 4A 28T: 100-240 , 50/60 Hz, 1 A 28TC: 100-240 , 50/60 Hz, 0.75 A 28P: 100-240 , 50-60 Hz, 4 A 52T: 100-240 , 50/60 Hz, 1 A 52P: 100-240 , 50-60 Hz, 6 A 12T: 30 W 12PH: 230 W PoE ) 12PH: 280 W 28T: 20 W 28TC: 20 W 28P: 260 W PoE ) 52T: 40 W 52P: 420 W PoE ) PoE RoHS TEC 12PH: 180 W 28P: 190 W 52P: 380 W EN55032 Class A EN IEC 61000-3-2 Class A EN 61000-3-3 BSMI (CNS15936) FCC Class A VCCI Class A EN 55035 IEC 61000-4-2/3/4/5/6/8/11 UL/CUL (UL 62368-1, CAN/CSA C22.2 No. 62368-1) CB (IEC 62368-1/EN 62368-1) BSMI (CNS15598-1) CNS15663 Certified ID 379401073 (ECS4100-12T ) 6 ECS4100 1. ECS4100-12T ECS4100-12PH ECS4100-28TC ECS4100-28T ECS4100-28P ECS4100-52T ECS4100-52P 2 8 4 -- -- RJ-45 DB-9 -- ECS4100 Safety and Regulatory Information - Web CLI www.edge-core.com 2. 3. 1 2 1 ETSI ETS 300 253 2 18 AWG 3.5 mm , 4. AC 1 1 AC AC 2 AC AC / 1 2 1 2 7 5. 1 1 Diag LED LED 6. 1 2 3 1 RJ-45 PC 2 115200 bps8 1 8 3 ( admin admin ) (CLI) CLI 7. 1 2 1 RJ-45 100-ohm Category 55e 2 SFP/SFP+ SFP/SFP+ : 1000BASE-SX (ET4202-SX) 1000BASE-LX (ET4202-LX) 1000BASE-RJ45 (ET4202-RJ45) 1000BASE-EX (ET4202-EX) 1000BASE-ZX (ET4202-ZX) 3 LED / -- / PoE 8 (W x D x H) 12T18.0 x 16.5 x 3.7 cm (7.08 x 6.49 x 1.45 ) 12PH33.0 x 20.5 x 4.4 cm (12.9 x 8.07 x 1.73 ) 28T/52T44 x 22 x 4.4 cm (17.32 x 8.66 x 1.73 ) 28TC33 x 23 x 4.4 cm (12.30 x 9.06 x 1.73 ) 28P/52P44 x 33 x 4.4 cm (17.32 x 12.30 x 1.73 ) 12T820 g 1.81 12PH2.38 kg 5.26 28T2.2 kg 4.85 28TC2.0 kg 4.41 28P3.96 kg 8.73 52T2.5 kg 5.5 52P4.4 kg 9.70 0°C ~ 50°C 32°F ~ 122°F -5°C ~ 50°C 23°F to 122°F, ECS410028P/52P 0°C ~ 45°C 32°F ~ 113°F, ECS4100-52T 0°C ~ 55°C 32°F ~ 131°F, ECS410012PH@70 W -5°C to 55°C 23°F to 131°F, ECS410012PH@125 W -5°C to 50°C 23°F to 122°, ECS410012PH@180 W -40°C ~ 70°C -40°F to 158°F 5% to 95% , ECS4100-28P/ 52P 10% ~ 90% 0% ~ 95% , ECS4100-12T ECS4100-12PH AC 12T100-240 VAC, 50-60 Hz, 0.5 A 12PH100-240 VAC, 50/60 Hz, 4A 28T100-240 VAC, 50/60 Hz, 1 A 28TC100-240 VAC, 50/60 Hz, 0.75 A 28P100-240 VAC, 50-60 Hz, 4 A 52T100-240 VAC, 50/60 Hz, 1 A 52P100-240 VAC, 50/60 Hz, 6 A 12T30 W 12PH230 W PoE 12PH280 W 28T20 W 28TC20 W 28P260 W PoE 52T40 W 52P420 W PoE 12PH180 W 28P190 W 52P380 W EN55032 Class A EN IEC 61000-3-2 Class A EN 61000-3-3 BSMI (CNS15936) FCC Class A VCCI Class A EN 55035 IEC 61000-4-2/3/4/5/6/8/11 UL/CUL (UL 62368-1, CAN/CSA C22.2 No. 62368-1) CB (IEC 62368-1/EN 62368-1) BSMI (CNS15598-1) CNS15663 RoHS TEC Certified ID 379401073 ( ECS4100-12T ) 9