Instruction Manual for VARI-LITE models including: TCWTWW Acclaim Led Fresnel, TCWTWW, Acclaim Led Fresnel, Led Fresnel, Fresnel
Downloadbereich
Vari-Lite Fresnel cast C.Adolph & RST Distribution GmbH DE
File Info : application/pdf, 28 Pages, 1.12MB
DocumentDocumentFRESNEL TUNABLE COOL WHITE TUNABLE WARM WHITE User Manual FRESNEL TCW/TWW User Manual INTRODUCTION OUR GOAL We are committed to providing you the highest quality in customer service. Our comprehensive resources are available to help your business succeed and ensure you get the full benefit of being a Vari-Lite customer. TECHNICAL SUPPORT Our Service and Support team is tasked with online and field support, repair, demo, commissioning, maintenance contracts, and technical training for fixtures and systems. In addition, this team plays a large role in a Systems sales, responsible for administering final commissioning, record-keeping, and organizing services. Refer to the back cover of this User Manual for contacts in your region or visit www.vari-lite.com/support CUSTOMER SERVICE Customer Service is responsible for boxed goods and spare parts quotations, order entry and fulfilment, project delivery, lead times, and general account management. They also manage all after sales warranty fulfilment, RGA, and repairs invoicing in tandem with our After Sales Service & Support team. Visit our website to find a customer service agent in your region. ADDITIONAL DOCUMENTATION Additional product documentation, including DMX maps, software, and photometric reports, are available for download on our website. For more information on installing DMX512 control systems, the following publication is available for purchase from the United States Institute for Theatre Technology (USITT), "Recommended Practice for DMX512: A Guide for Users and Installers, 2nd edition" (ISBN: 9780955703522). USITT Contact Information: USITT 315 South Crouse Avenue, Suite 200 Syracuse, New York 13210-1844 USA Phone: 800-938-7488 or +1-315-463-6463 Fax: 866-398-7488 or +1-315-463-6525 Website: www.usitt.org ABOUT THIS DOCUMENT Read all instructions before installing or using this product. Retain this User Manual for future reference. Additional product information and descriptions may be found on the product data sheet(s) which can be downloaded from the website at www.vari-lite.com. This User Manual provides necessary information regarding safety, installation, operation and routine maintenance for Fresnel TCW/TWW. Familiarizing yourself with this information will help you to get the most out of your product. WARNING: It is important to read ALL accompanying safety and installation instructions to avoid damage to the product and potential injury to yourself or others. 2 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW User Manual SAFETY WARNINGS AND NOTICES Read this user manual in full before attempting to install, operate or maintain the fixture to which it relates. This user manual is intended to provide general guidance to such suitably qualified personnel. Installation and operation of the fixture are to be performed by qualified personnel only. When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS. · For indoor, dry location use only. Do not use outdoors unless fixture is suitably IP rated. · Use safety tether when mounting. · Equipment should be mounted in locations and at heights where it will not be readily subjected to tampering by unauthorized personnel. · Not for residential use. Do not use this equipment for other than intended use. · Note distance requirement(s) from combustible materials or illuminated objects. Do not mount near gas or electric heaters. · Install only in locations with adequate ventilation. Ensure sure that ventilation slots are not blocked. · Ensure that the voltage and frequency of the power supply match the power requirements of the fixture. · The fixture must be earthed/grounded to the appropriate conductor. · Do not operate fixture outside the specified ambient temperature range. · Do not connect the fixture to any dimmer pack. · The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition and void warranty. · Refer service to qualified personnel. This fixture contains no user serviceable parts. · Prior to first use, carefully inspect fixture to ensure no damage has occurred during shipping. · Materials used in the manufacturing process can cause strong odors when the product is new. These odors dissipate over time. · Prior to each use, carefully inspect power cables and replace any damaged cables. · Exterior surfaces of the luminaire will be hot during operation. Take appropriate precautions. · Continuous use of the fixture may shorten the lifespan. Power down the fixture when not in use. · Do not cycle power on and o repeatedly. Disconnect mains power if the fixture is not used for an extended period. · Clean fixtures regularly, particularly when working in a dusty environment. · Never touch power cables or wires while the fixture is powered on. · Avoid entangling power wires with other cables. · In the event of a serious operating problem, immediately discontinue using the fixture. · It is hazardous to operate luminaires without lens or shield. Shields, lenses, or ultraviolet screens shall be changed if they have become visibly damaged to such an extent that their e ectiveness is impaired, for example, by cracks or deep scratches. · Original packing materials can be reused for transporting the fixture. · Do not look directly at the LED light beam while the fixture is on. · This is a Class A product. In a domestic environment this product may cause radio interference, in which case, the user may be required to take adequate measures. · The light source contained in this luminaire shall only be replaced by the manufacturer or service agent or similarly qualified person. SAVE THESE INSTRUCTIONS. WARNING: Refer to National Electrical Code® and local codes for cable specifications. Failure to use proper cable can result in damage to equipment or danger to personnel. Caution Against Direct Sunlight Through Front Lens Assembly 3 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW User Manual CAUTION AGAINST DIRECT SUNLIGHT THROUGH FRONT LENS ASSEMBLY The design and nature of the front lens assembly in Vari-Lite LLC luminaires is to e ciently focus the light energy from the luminaire's lamp for maximum light output. · When the front lens assembly is exposed to direct sunlight or intense light from neighboring fixtures, the lens will collect and intensify this light and focus it back into the fixture. Intense sunlight or beams from other fixtures can cause damage to internal assemblies contained within the fixture. · When fixture is not in use and direct sunlight or other intense light is present, position luminaires so their front lens assembly it not directly exposed to the light source. CAUTION AGAINST POWERING LUMINAIRES FROM DIMMER CIRCUITS It is not recommended to power any Vari-Lite LLC luminaire from a dimmer - even in `NONDIM' mode. Dimmer and non-dim modules are not suitable sources of power because their output modifies the AC wave form. This may work for a short time, but eventually results in power problems, luminaire mis-operation and/or failure. · When using a power distribution rack, do not use dimmer or non-dim modules to power any Vari-Lite LLC luminaire. Damage to the luminaire can occur. · Using a dimmer or non-dim module to power your Vari-Lite LLC luminaire will void your luminaire's warranty. CAUTION AGAINST THE USE OF THIRD PARTY PARTS OR ACCESSORIES · Heat and heat distribution are important factors when operating Vari-Lite LLC luminaires. Vari-Lite LLC luminaires are designed to dissipate heat e ciently and safely. Any blockages or obstructions, such as aftermarket ba es, covers, enclosures, etc. can interrupt the luminaire's ability to dissipate heat properly and can damage the luminaire. · Vari-Lite LLC cannot be responsible for issues arising from non-approved parts and accessories installed on or used with any Vari-Lite LLC product. Customers of such products should contact the manufacturer directly for assistance and support. TRANSPORTING LUMINAIRES When shipping or transporting luminaires, Vari-Lite LLC recommends that the luminaire(s) be su ciently protected against any (including, but not limited to) shock, vibration, drops, jarring, exposure to the environment, etc. Failure to su ciently protect any Vari-Lite LLC luminaire during shipping or transportation will result in damage and void the luminaire's warranty. Vari-Lite LLC will not be responsible for any shipping damage or breakage of any product under any circumstances. Vari-Lite LLC will not be responsible for any third party case manufacturer's cases. NOTE: As with all automated luminaires, proper handling and suitable protective shipping cases should be used when transporting fixtures to reduce the risk of damage. TRANSPORTATION AND SHIPPING CASE REQUIREMENTS Cases to transport Vari-Lite LLC luminaires should meet the following loading requirements: · Luminaire head, yoke, and enclosure sub-assemblies shall be equally supported and constrained where no one sub-assembly (head, yoke, or enclosure) fully supports the entire mass of the luminaire. · The interior of the case shall be of high quality and uniform density foam. The foam shall be of the same type and density throughout as to equally and uniformly support loading at every contact surface. · The case shall, when laid on any of its six (6) surfaces, maintain the loading requirements outlined above. · All cases not meeting the aforementioned loading requirements, with wheels, shall have markings on the exterior of the case that the unit is to be transported on it wheels only (e.g. "Case must be transported and remain [at all times] on its wheels"). 4 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW User Manual COMPLIANCE NOTICE FCC DECLARATION OF CONFORMITY This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with Vari-Lite system, service, and safety guidelines, may cause harmful interference to radio communications. As tested under this standard: FCC 47CFR 15B clA*CEI Issued:2009/10/01 Title 47 CFR Part 15 Subpart B Unintentional Radiators Class A Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his/her own expense. EU DECLARATION OF CONFORMITY We, Vari-Lite LLC., 10911 Petal Street, Dallas, Texas 75238, declare under our responsibility for the products contained herein are in conformity with the essential requirements of the following European Directives and harmonized standards: Low Voltage Director (LVD), 2006/95/EC EN 60589-2-17:1984+A1:1987+A2:1990 used in conjunction with 60598-1:2008/A11:2009 Electromagnetic Compatibility Directive (EMC), 2004//108/EC EN 55022:2010, EN55024:2010 5 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW User Manual HOW TO OBTAIN WARRANTY SERVICE A copy of the Limited Warranty card was included in the shipping package for this product. To obtain warranty service, please contact customer service at 1-214-647-7880, or entertainment.service@ signify.com and request a Return Material Authorization (RMA) for warranty service. You will need to provide the model and serial number of the item being returned, a description of the problem or failure and the name of the registered user or organization. If available, you should have your sales invoice to establish the date of sale as the beginning of the warranty period. Once you obtain the RMA, pack the unit in a secure shipping container or in its original packing box. Be sure to clearly indicate the RMA number on all packing lists, correspondence, and shipping labels. If available, please include a copy of your invoice (as proof of purchase) in the shipping container. With the RMA number written legibly on or near the shipping address label, return the unit, freight prepaid, to: Vari-Lite LLC Attention: Warranty Service (RMA# ________) 10911 Petal Street Dallas, Texas 75238 USA As stated in the warranty, it is required that the shipment be insured and FOB our service center. IMPORTANT! When returning products to Vari-Lite for repairs (warranty or out-of-warranty) from a country other than the USA, "Vari-Lite LLC", must appear in the address block as the Importer of Record (IOR) on all shipping documentation, Commercial Invoices, etc. This must be done in order to clear customs in a timely manner and prevent returns. 6 W W W.VAR I - L I T E . C O M CRI exceeding >94 CRI across the range. The LED Fresnel is also available in full color (RGBALC) and tunable warm white (2700K to FRESNEL T4C50W0K/) TveWrsioWns. The Fresnel uses a manually operated zoom system located on either side near the front of the luminaire, providing a smooth zoom range of 10° to 55°. The locking default 1 D ES C R I P T I O N standard size accessory rails located at the front of the fixture allows for further beam shaping using the optional 8 leaf barndoor or thirdparty accessories. To ensure these high-powered LED fixtures are suitable for use in the quietists of applications, the Vari-Lite Fresnel F E AT U RuEtilizSes SmartFan Control technology with Standard, Studio, and Whisper modes. User Manual · High output midsized LED theatrical luminaires - modern fixtures with quality you can trust. · Tunable white with >94 CRI - adjust color temperature without compromising output or quality of light. · Standard-size accessory rails to support optional 8 leaf barn door or third - party accessories- multiple, easily-accessible options to get the perfect look. · Adjustable frequency to exceed camera frame rates - camerafriendly fixtures for IMAG, event recordings, or TV and film applications. · Quiet operation with variable fan control (Standard, Studio, and Whisper) - perfect for use in quiet environments. For detailed product information, please refer to the Product Guide at https://www.vari-lite.com/global/products/fresnel-tcw COMPONENTS The document provides installation and operation instructions for the following products: · Fresnel TCW or Fresnel TWW Read all instructions before installing or using this product. Retain this manual for future reference. Additional product information and descriptions may be found on the product specification sheet. INCLUDED ITEMS Each Fresnel luminaire includes the following items: · Fresnel TCW or LED Fresnel TWW · TrueOne compatible power connector FRESNEL_TCW · Quick Start Guide INCLUDED ITEMS FRESNEL TCW/TWW POWER CONNECTOR QUICK START GUIDE (this document) 7 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW User Manual 2 INSTALLATION MOUNTING The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit's weight. Always use a safety cable that can hold up to 12 times the weight of the unit when installing the fixture. The luminaire must be mounted by professionals. Clamp Hanging Bracket NOTE: Truss hooks shown are sold separately. Truss and pipe by others. 8 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW User Manual 3MENU OPERATION CONTROL PANEL Press the MENU button to select any functions, until the required function is shown in the display. Select the desired function by pressing ENTER, which will cause the display to blink. Use the UP and DOWN button to change the mode. Once the required mode has been selected, press the ENTER button to accept the selection. Press MENU to return to the previous menu or let the unit idle for one minute to exit menu mode automatically. 1 2 9 78 53 64 1 LCD DISPLAY. Shows the menu and selected function buttons. 2 BUTTONS. Menu. To select programming functions. Down. To go backward in the selected functions. Up. To go forward in the selected functions. Enter. To confirm the selected functions. 3 DMX IN. 5-pin XLR cable to link DMX console. 4 DMX OUT. 5-pin XLR cable to the next unit. 5 POWER IN. Connects to power supply. 6 POWER OUT. Connects to next fixture. 7 DIM. 0-100% 8 CCT. 4000K to 6500K (TCW) or 2700K to 4500K (TWW) 9 ZOOM. Manual zoom knob. 9 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW User Manual LEVEL 1 address Configure DMX Fixture LEVEL 2 LEVEL 3 LEVEL 4 LEVEL 5 LEVEL 6 001~506(16 Bit), 001-508(8 Bit), 001-511(2 Channel) leD Hours XXXXXX h reset leD Hour are you sure? square Curve Dimming Curve s Curve linear Curve Dim snap On (Fast) Off (slow) standard leD Output Mode studio Whisper Fan Mode On auto 1200Hz 2500Hz leD Frequency 5000Hz 10000Hz 20000Hz 25000Hz 30 sec Disp Timeout 5 Min 10 Min On reset Yes/no address 001~506(16 Bit), 001-508(8 Bit), 001-511(2 Channel) 16 Bit DMX Mode 8 Bit 2 Channel Hold DMX Fail Blackout Go to Preset Ch 1 - Intensity XXX (Value) Data Ch 2 -Intensity Fine XXX (Value) ...all functions UID UID electronic format status (no errors..or displays a list of errors) reboot Fixture are you sure? Version VXXX Fixture Hours XXXXXX h Crossload (software) send Fan Check X rpm service Diagnostics Board Check (no errors..or displays a list of errors) sensor Check X °C DEFAULT 001 Default Default Default Default Default Default 001 Default Default 10 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW User Manual LEVEL 1 LEVEL 2 Playback Manual Preset LEVEL 3 Power Up Preset Intensity Priority Power Up? load Preset edit settings edit Programs store Clear Dial Mode enables the manual control knobs Clear all Knob 1 Intensity 0 - 100% Double press at anytime to activate Dial Mode LEVEL 4 01 - 20 0 - 255 Preset DMX Off On 01 - 20 Intensity Cool or Warm nautural 01 - 20 LEVEL 5 0 - 255 0 - 255 0 - 255 are you sure? 01 - 20 are you sure? Yes are you sure? no Knob 2 CCT 4000K - 6500K (TCW) 2700K - 4500K (TWW) LEVEL 6 Yes no Yes no DEFAULT 255 Default Default 11 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW MENU SYSTEM User Manual DISPLAY AND MENU SYSTEM OPERATION The Display Menu system consists of several categories. Use the Menu Button to access the menu. Then use the Up/Down arrow to navigate. When you reach the desired item, touch the Enter Button. To go backwards, touch the Menu Button. To navigate and access menu settings/selections: Step 1. Make sure unit is powered and turned on. Step 2. Touch [MENU] to access menu categories. Step 3. Use two Arrow () buttons to navigate through the various options and settings. Step 4. Once menu item is reached, touch [ENTER] to access the menu item parameters. Step 5. Make changes to parameters as desired. Step 6. Press [ENTER] button to accept changes. ADDRESS ADDRESS Sets the starting DMX address for the fixture. Can also be set via RDM. CONFIGURE LED This menu allows for viewing the LED engine hours, setting the dimming curve, dim snap, output mode, fan mode, and LED frequency. LED Hours Displays the current LED engine hours. Reset LED Hours Allows the LED hours of the engine to be reset. Should only be done if the engine has been replaced Dimming Curve Select from Linear, S-Curve and Square Law. Can also be set via the control channel and RDM. Dim Snap Dim Snap On allows for fastest output changes between levels but reduces smoothness dimming the LED engine. Dim Snap Off ensures all fades between output levels remains smooth and flicker free but limits fast, instant snaps between levels. Can also be set via the control channel and RDM. Output Mode Standard mode provides full LED output. Studio mode reduces fan speed to reduce the fan noise of the fixture. Whisper mode decrease the fan noise further. In both Studio mode and Whisper mode, the LED output will decrease accordingly. Can also be set via the control channel and RDM. Fan Mode Fan On runs fans at continuous max speed based on Output Mode. Fan Auto will reduce/increase speed on demand based on LED operating temperature. The fan will not exceed the maximum permissible level based on Output Mode. Can also be set via the control channel and RDM. See Appendix B. 12 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW LED Frequency Choose the refresh rate of the LED engine (see Display Menu Tree for list). User Manual DISPLAY TIMEOUT Sets how long the display remains illuminated after the last button touch. Choose from 30 seconds, 5 minutes, 10 minutes, or always on. RESET Resets all the factory defaults of the fixture. This includes setting the DMX Address to 001. Can also be done via RDM and via the control channel. NOTE: Control channel will not change the current DMX address. DMX ADDRESS Sets the starting DMX address of the fixture. Can also be set via RDM. DMX MODE 16 Bit 16 Bit DMX control of Intensity and CCT, plus 8 Bit DMX control of Strobe, Fan and Luminaire Control. 8 Bit 8 Bit DMX control of Intensity, CCT, Strobe, Fan and Luminaire Control. 2 Channel 8 Bit DMX control of Intesnity and CCT. DMX FAIL DMX Hold If DMX is lost, fixture will maintain its present state until DMX is restored. Blackout If DMX is lost, fixture will go to blackout until DMX is restored. Goto Preset If DMX is lost, fixture will go to the preset (1 through 20). DATA Allows the current DMX value present on each of the luminaire's DMX channels to be viewed. 13 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW User Manual FIXTURE UID Displays the UID as set in the luminaire. S TAT U S Shows list of error message from previous calibration. If none, it will say No Errors. REBOOT FIXTURE Restarts the entire operating system of the fixture. Can be performed via the control channel or RDM. VERSION Shows the current software version of the fixture. Version is listed in MM/DD/YY format. Can be viewed via RDM. FIXTURE HOURS Shows the accumulated hours the fixture has been powered on. Can be viewed via RDM. CROSSLOAD (SOFTWARE) Allows the current version of software installed in the fixture to be sent to other units via an attached DMX cable. SERVICE - DIAGNOSTICS Fan Check Shows the current fan speed in RPM. Board Check Shows the current status of the control board. Sensor Check Shows the current temp at the LED in °C. MANUAL PRESET P L AY B AC K Power Up Preset Selects the preset (1 to 20) that will be played back after power up if enabled. Intensity Selects the master intensity of a preset being played back (0 to 255). Priority Choose Preset if you always want a preset to playback. Choose DMX if you only want a preset to playback if there is no DMX present. Power Up? Choose Preset On if you want the fixture to playback the preset at power up. Choose Preset Off if you do not want a preset to play. 14 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW User Manual EDIT PROGRAMS Load Preset Select from preset 1 to 20 and touch [ENTER]. That preset will be played back. Edit Settings Choose the function from the list you wish to edit and touch [ENTER]. Use the [UP]/[DOWN] buttons to set desired value. Touch [ENTER] to store. Then continue to adjust all function desired. Store After setting all your functions, select which preset number you wish to store (1 to 20) and touch [ENTER]. Touch [ENTER] again to confirm when prompted. Clear Select the preset (1 to 20) you wish to clear and touch [ENTER]. Touch [ENTER] again to confirm when prompted. Clear All Presets When prompted, touch [ENTER] to confirm and all presets (1 to 20) will be erased. WARNING: Clearing the presets CANNOT be undone! DIAL MODE Allows the use of the manual knobs below the display. Can be selected via the UI by touching [ENTER] at DIAL MODE. May also be selected at any time by double clicking the first knob. Use the first knob to adjust the intensity from 0 to 100%. Use the second knob to adjust the CCT from 4000K to 6500K on the TCW and from 2700K to 4500K on the TWW. NOTE: Dial Mode will overide the current DMX values. Exiting Dial Mode will return the fixture to DMX control. MENU DIMMER 0% ENTER CCT 4000K UP DOWN 15 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW User Manual 4DMX MAPPING The fixture can be operated by DMX controller. The following tables assumes a DMX start address of 1. When a different starting address is used, this address becomes channel 1 function and other functions follow in sequence. TABLE 1.16 BIT DMX CHANNEL PARAMETER DEFAULTS RANGE DMX DESCRIPTION 1 Intensity (High) 0 0 - 65535 16-bit Intensity (Dimmer) Control 2 Intensity (low) 0 - 100% Outut 0 - 255 Control of strobe 0 - 9 no strobe Function - shutter open 10 - 99 strobe s>>>>>F 3 strobe 0 100 - 109 no strobe Function - shutter open 110 - 179 lighting strobe s>>>>>F 180 - 189 no strobe Function - shutter open 190 - 255 random strobe s>>>>>F 0 - 255 Dynamic control of fan speed vs leD output 0 - 4 automatic fan/output adjustment 4 Fan Control linear control fo fan speed and leD output* 0 DMX 5 = Highest Constant Fan speed 5 - 255 DMX 255 = lowest Constant Fan speed * standard mode only 0 - 255 Control Channel used for fixture settings set discrete value of desired effect, wait >3 seconds, then set value to 0 (idle) **Function does not require 3 second rule to activate function 0 - 5 Idle (Default must be 0) 6 - 10 Full luminaire re-Cal - also wakes from shutdown 11 - 15 Fixture shutdown 16 - 20 reserved 21 - 25 Display - Menu On 26 - 30 Display - Menu OFF 31 - 40 reserved 41 - 45 Dimming Curve linear** 46 - 50 Dimming Curve s-Curve** 5 Control Channel 0 51 - 55 Dimming Curve square law (Default)** 56 - 60 reserved 61 - 65 Dimmer snap On** 66 - 70 Dimmer snap Off (Default)** 71 - 110 reserved 111 - 115 standard Mode (Default) 116 - 120 studio Mode - reduced output with lower fan 121 - 125 Whisper Mode - reduced output with lower fan 126 - 135 reserved 136 - 140 Fan On (Default) 141 - 145 Fan auto 146 - 170 reserved 171 - 175 reset defaults 176 - 255 reserved 6 CCT High 7 CCT low Tunable leD array 0 - 100% 0 0 - 65535 0 = 4000K (TCW) or 2700K (TWW) 255 = 6500K (TCW) or 4500K (TWW) 16 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW User Manual TABLE 2.8 BIT DMX CHANNEL PARAMETER 1 Intensity 2 strobe 3 Fan Control 4 Control Channel 5 CCT DEFAULTS 0 0 0 0 0 RANGE DMX DESCRIPTION 0 - 255 0 - 255 0 - 9 10 - 99 100 - 109 110 - 179 180 - 189 190 - 255 0 - 255 0 - 4 5 - 255 0 - 255 0 - 5 6 - 10 11 - 15 16 - 20 21 - 25 26 - 30 31 - 40 41 - 45 46 - 50 51 - 55 56 - 60 61 - 65 66 - 70 71 - 110 111 - 115 116 - 120 121 - 125 126 - 135 136 - 140 141 - 145 146 - 170 171 - 175 176 - 255 0 - 255 8 bit Intensity (Dimmer) Control 0 - 100% Output Control of strobe no strobe Function - shutter open strobe s>>>>>F no strobe Function - shutter open lighting strobe s>>>>>F no strobe Function - shutter open random strobe s>>>>>F Dynamic control of fan speed vs leD output automatic fan/output adjustment linear control fo fan speed and leD output* DMX 5 = Highest Constant Fan speed DMX 255 = lowest Constant Fan speed * standard mode only Control Channel used for fixture settings set discrete value of desired effect, wait >3 seconds, then set value to 0 (idle) **Function does not require 3 second rule to activate function Idle (Default must be 0) Full luminaire re-Cal - also wakes from shutdown Fixture shutdown reserved Display - Menu On Display - Menu OFF reserved Dimming Curve linear** Dimming Curve s-Curve** Dimming Curve square law (Default)** reserved Dim snap On** Dim snap Off (Default)** reserved standard Mode (Default) studio Mode - reduced output with lower fan Whisper Mode - reduced output with lower fan reserved Fan On (Default) Fan auto reserved reset defaults reserved Tunable leD array 0 - 100% 0 = 4000K (TCW) or 2700K (TWW) 255 = 6500K (TCW) or 4500K (TWW) 17 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW User Manual TABLE 3.2 CHANNEL DMX CHANNEL PARAMETER 1 Intensity 2 CCT DEFAULTS 0 0 RANGE DMX DESCRIPTION 0 - 255 0 - 255 5 - 255 8 bit Intensity (Dimmer) Control 0 - 100% Output Tunable leD array 0 - 100% 0 = 4000K (TCW) or 2700K (TWW) 255 = 6500K (TCW or 4500K (TWW) linear control fo fan speed and leD output* DMX 5 = Highest Constant Fan speed DMX 255 = lowest Constant Fan speed * standard mode only 18 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW User Manual TABLE 4.CONTROL CHANNEL DMX RANGE ITEMS DESCRIPTION POWER CYCLE RULES Control channel used for fixture settings 0 - 255 Control Channel set discrete value of desired effect, wait >3 seconds, then set value to 0 (idle) n/a **Function does not require 3 second rule to activate function 0 - 5 Idle (Default) Default value used to active functions. should default to 0 n/a 6 - 10 Full luminaire reCal recalibrates all functions in the luminaire. also used to wake from shutdown n/a 11 - 15 Fixture shutdown shuts down all fixture output and turns off all fans. Fixture can be re-actived by a power cycle or via the reCal command Will restart normally 16 - 20 reserved 21 - 25 Display - Menu On switches UI display on remotely - Display will time out as set in UI n/a 26 - 30 Display - Menu Off switched UI display off remotely if on. n/a 31 - 40 reserved 41 - 45 Dimming Curve linear** selects linear Dimming Curve Holds setting on power cycle 46 - 50 Dimming Curve s-Curve** selects s-law Dimming Curve Holds setting on power cycle 51 - 55 Dimming Curve square law (Default)** selects square law Dimming Curve Holds setting on power cycle 56 - 60 reserved 61 - 65 Dimmer snap On** allows for fastest output changes between levels but reduces smoothness of dimming and color Holds setting on power cycle 66 - 70 Dimmer snap Off ensure fades between levels remain smooth and flicker free (Default)** but limits instand snaps Holds setting on power cycle 71 - 110 reserved 111 - 115 standard Mode (Default) standard mode - Full leD output + full continuous fan at max speed (loudest setting). Fan remains at constant speed (unless in fan auto mode). nC40 Holds setting on power cycle 116 - 120 studio Mode studio mode - Fan speed reduced to reduce dB levels 10% of full speed and leD output approximatly 80% of standard. Fan remains constant speed (unless in fan auto mode). nC35 Holds setting on power cycle 121 - 125 Whisper Mode Whisper Mode - Fan speed reduced to reduce dB levels 30% of full speed and leD output approximatly 60% of standard. Fan remains constand speed (unless in fan auto mode). nC25 Holds setting on power cycle 126 - 135 reserved 136 - 140 Fan On (Default) Fan runs at continuous speed for selected output mode Holds setting on power cycle 141 - 145 Fan auto Fans will increase/decrease speed based on leD operation Holds stting on power cycle 146 - 170 reserved 171 - 175 reset default resets all paramters to factory default with the exception of DMX address and fixture DMX Mode n/a 176 - 255 reserved FUNCTION SELECTION VIA UI n/a n/a Yes Yes, press Menu twice to wake Button press turns display on n/a Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes, but will reset DMX address and DMX Mode 19 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW User Manual DMX512 CONNECTION · At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 5-pin XLR-plug and plug it in the DMX-output of the last unit. · Connect the unit together in a `daisy chain` by XLR plug from the output of the unit to the input of the next unit. The cable cannot branched or split to a `Y` cable. DMX 512 is a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors can easily distort the signal and shut down the system. · The DMX output and input connectors are pass-through to maintain the DMX circuit, when one of the units' power is disconnected. · Each lighting unit needs to have an address set to receive the data sent by the controller. The address number is between 0-511 (usually 0 & 1 are equal to 1). · The end of the DMX 512 system should be terminated to reduce signal errors. · 5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), Pin 4/Pin 5: Not used. 20 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW User Manual 5RDM PARAMETER IDs Remote Device Management (RDM) is a protocol enhancement to USITT DMX512 that allows bi-directional communication between a lighting or system controller and attached RDM compliant devices over a standard DMX line. This protocol will allow configuration, status monitoring, and management of these devices in such a way that does not disturb the normal operation of standard DMX512 devices that do not recognize the RDM protocol. Model ID 0x0119 0x011a Leko LED Outdoor, RDM PRODUCT PARAMETER IDS Manufacturer Vendor ID Model Description Vari-Lite 0x564C Fresnel TCW Vari-Lite 0x564C Fresnel TWW Product Category 0x0101 0x0101 The table on the following pages outlines and describes all the RDM parameters IDs associated with the. 21 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW User Manual GET SET ALLOWED ALLOWED RDM PARAMETER IDS VALUE COMMENT ESTA STANDARD REQUIRED / DMX / UI DESCIPTION Category - network Management DIsC_UnIQUe_BranCH 0x0001 X DIsC_MUTe 0x0002 X DIsC_Un_MUTe 0x0003 X X PrOXIeD_DeVICes 0x0010 X PrOXIeD_DeVICes_COUnT 0x0011 X X COMMs_sTaTUs 0x0015 Category - status Collection X QUeUeD_MessaGe 0x0020 X sTaTUs_MessaGes 0x0030 X sTaTUs_ID_DesCrIPTIOn 0x0031 X Clear_sTaTUs_ID 0x0032 X X sUB_DeVICe_sTaTUs_ 0x0033 rePOrT_THresHOlD Category - rDM Information X sUPPOrTeD_ParaMeTers 0x0050 X X ParaMeTer_DesCrIPTIOn 0x0051 X Category - Product Information X DeVICe_InFO 0x0060 X X PrODUCT_DeTaIl_ID_lIsT 0x0070 X DeVICe_MODel_ 0x0080 DesCrIPTIOn X ManUFaCTUrer_laBel 0x0081 X X DeVICe_laBel 0x0082 X X FaCTOrY_DeFaUlTs 0x0090 X lanGUaGe_CaPaBIlITIes 0x00a0 X X lanGUaGe 0x00B0 X sOFTWare_VersIOn_ 0x00C0 X laBel X BOOT_sOFTWare_ 0x00C1 VersIOn_ID X BOOT_sOFTWare_ 0x00C2 VersIOn_laBel Category - DMX512 setup X X DMX_PersOnalITY 0x00e0 X DMX_PersOnalITY_ DesCrIPTIOn 0x00e1 X X DMX_sTarT_aDDress 0x00F0 X X slOT_InFO 0x0120 X slOT_DesCrIPTIOn 0x0121 X DeFaUlT_slOT_ValUe 0x0122 Category sensors 0x02xx Use X sensOr_DeFInITIOn 0x0200 X X sensOr_ValUe 0x0201 Fan speed and X reCOrD_sensOrs 0x0202 Category - Dimmer settings 0x03xx - FUTUre Use X X Dimmer Curve 0x0343 X X X X status X X X X X X X X reset Defaults X Version X DMX Mode X X address X X X X X Diagnostics X 22 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW User Manual GET SET ALLOWED ALLOWED RDM PARAMETER IDS VALUE COMMENT ESTA STANDARD REQUIRED / DMX / UI DESCIPTION X Dimmer Curve Description 0x0344 X X Modulation Frequency 0x0347 X Modulation Frequency Description 0x0348 Category - Power / lamp settings 0x04xx X X DeVICe_HOUrs 0x0400 X X laMP_HOUrs 0x0401 X X laMP_sTrIKes 0x0402 X X laMP_sTaTe 0x0403 X X laMP_On_MODe 0x0404 X X DeVICe_POWer_CYCles 0x0405 Category - Display settings 0x05xx X X DIsPlaY_InVerT 0x0500 X X DIsPlaY_leVel 0x0501 Category - Configuration 0x06xx X X Pan_InVerT 0x0600 X X TIlT_InVerT 0x0601 X X Pan_TIlT_sWaP 0x0602 X X real_TIMe_ClOCK 0x0603 Category - Control 0x10xx X X IDenTIFY_DeVICe 0x1000 X X reseT_DeVICe 0x1001 X X POWer_sTaTe 0x1010 all Test, X X PerFOrM_selFTesT 0x1020 Pan/Tilt, encoder X selF_TesT_DesCrIPTIOn 0x1021 X CaPTUre PreseT 0x1030 see e120_2010a X X PreseT PlaYBaCK 0x1031 Table a-7 defines esTa reserved Future rDM 0x7Fe00x7FFF Manufacturer-specific PIDs 0x80000xFFDF Value range depends X X Output Power Mode 0x8a97 on options (standard, studio, etc) X X Pan/Tilt Feedback (On/Off) 0x8aD3 X X Display On Time 0x8aa0 Value range depends on options Value range X X leD Dimmer Curve 0x8aa1 depends on options X X Pan Tilt Movement (On/Off) 0x8aa2 X X Head Motor Movement (On/ Off ) 0x8aa3 X X X X Fixture Hours X X leD Output Mode X Display On X Time leD Dimming Curve 23 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW User Manual GET SET ALLOWED ALLOWED RDM PARAMETER IDS VALUE COMMENT ESTA STANDARD REQUIRED / DMX / UI DESCIPTION Value range X X auto shutdown Mode 0x8aa4 depends on options X X leD Hours 0x8aa5 X X Dim snap (On/Off) 0x8aa6 X X Color snap (On/Off) 0x8aa7 X X auto Fan Mode (On/Off) 0x8aa8 X X Gamma shift 0x8aa9 Value range depends on options X X Tungsten Dimming (On/ Off ) 0x8aaa X X CTB Correction (On/Off) 0x8aaB X X leD refresh rate 0x8aaC Value range depends on options X X side Hang (On/Off) 0x8aaD X X Focus Track (On/Off) 0x8aae X Control signel select DMX only/artneT (On/Off) 0x8aaF different X recalibrate Fixture (level) 0x8aB0 levels (all, position, color, etc) X X DMX Fail (Hold, Blackout, GOTO Preset) 0x8aB1 X X artnet Universe 0x8aB2 X X artnet net 0x8aB3 X X artnet sub-net 0x8aB4 X X artnet ethernet IP 0x8aB5 X X artnet ethernet sub-net Mask 0x8aB6 X X Manual PreseT Playback Power Up Preset 0x8aB7 X X Manual PreseT Playback Preset Intensity 0x8aB8 X X Manual PreseT Playback Priority 0x8aB9 X X Manual PreseT Playback Power Up? 0x8aBa X X leD Color Calibration (On/ Off ) 0x8aBB leD Fan Mode leD refresh rate DMX Fail leD Color X Calibration 24 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW User Manual Appendix A CARE AND MAINTENANCE TROUBLeSHOOTinG The following are a few common problems that may occur during operation. Luminaire does not work; light and fan do not turn on. · Check power connection and main fuse. · Measure the mains voltage on the main connector. Not responding to DMX controller. · If DMX LED is not illuminated, verify that the DMX cables are properly connected. · If the DMX LED is illuminated and there is no response, verify DMX address settings and the DMX polarity. · If you experience intermittent DMX signal problems, check the pins on the connectors or on the PCB. · Test with a di erent DMX controller. · Check if the DMX cables run near or alongside high voltage cables that may cause interference to the DMX interface circuit. CLeAninG Cleaning the inside of the luminaire must be carried out periodically in order to optimize the light output.Cleaning frequency depends on the environment in which the fixture operates. Damp, smoky or particularly dusty surroundings can cause greater accumulation of dirt on the fixture's optics. · Clean with a soft cloth using glass cleaning fluid. · Dry parts carefully. · Clean the external optics at least every 30 days. 25 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW User Manual Appendix B FAN SPEED AND CONTROL AddendUM FAn Speed And COnTROL All Vari-Lite luminaires will be governed by the same fan speed vs. noise levels. vs. maximum power output rules as detailed below. The noise related to these levels will conform to the Noise Criteria levels, details of which are contained within this document. There are three control parameters that can be selected separately or in conjunction (when permitted) to manage fan speed vs. noise levels vs. maximum power output. NOTE: Not all fixtures have all modes or functions. Refer to DMX map and User Interface menu tree to see if your product has one or more of these functions. Output Modes These modes are selectable at the fixture's DMX control channel or via the fixture's user interface screen. Boost mode - LED output boosted to >100% of standard output. Fan speeds increased to manage heat level of LED (may be limited to only run for XX hours). Fixture will not exceed NC45-NC55 sound levels in this mode. Standard mode - Full LED output. Fan speed is set to cool LED appropriately but not exceed NC40 sound level in this mode. Studio mode - Fan speed reduced to achieve 10% dB reduction from Standard mode and not exceed NC35 sound level. LED output is approximately 80% of Standard output to ensure LEDs operate at optimum temperature and output e ciency. Fan speed remains constant and does not ramp up or down. Whisper mode - Fan speed reduced to achieve 30% dB reduction from Standard mode and not exceed NC25 sound level. LED output is approximately 60% of Standard output to ensure LEDs operate at optimum temperature and output e ciency. Fan speed remains constant and does not ramp up or down. Silent mode - fans are turned o or turn very slowly to not contribute to fixture noise. LED output is capped to ensure LEDs operate at optimum temperature and output e ciency. Fans are either o or fan speed remains constant. Target NC15 sound level in this mode. SOUND PRESSURE LEVEL (dB) 90 80 70 NC 55 NC 55 60 NC 55 NC 55 50 NC 50 NC 45 40 NC 40 30 NC 35 NC 30 20 NC 25 NC 20 10 NC 15 0 63 125 250 500 1000 2000 4000 8000 FREQUENCY (HZ) MOde Boost Mode Standard Mode Studio Mode Whisper Mode Silent Mode Led OUTpUT >100% Full 100% 80% 60% TBC FAn Speed Boosted fan speed constant Full 100% constant Appropriate speed to reduce dB levels >10% of full speed Appropriate speed to reduce dB levels >30% of full speed Fan off nOiSe CRiTeRiOn NC45 NC40 NC35 NC25 NC15 eQUiVALenT SOUnd LeVeL dBA (@3M) 50 45 40 35 25 nOiSe CRiTeRiOn 63 NC-15 47 NC-20 51 NC-25 54 NC-30 57 NC-35 60 NC-40 64 NC-45 67 NC-50 71 NC-55 74 NC-60 77 NC-65 80 NC-70 83 OCTAVe BAnd CenTeR FReQUenCY (HZ) 125 250 500 1000 2000 4000 8000 SOUnd pReSSURe LeVeLS (dB) 36 29 22 17 14 12 11 40 33 26 22 19 17 16 44 37 31 27 24 22 21 48 41 35 31 29 28 27 52 45 40 36 34 33 32 56 50 45 41 39 38 37 60 54 49 46 44 43 42 64 58 54 51 49 48 47 67 62 58 56 54 53 52 71 67 63 61 59 58 57 75 71 68 66 64 63 62 79 75 72 71 70 69 68 vls_adm_fan-tk-jan 26 W W W.VAR I - L I T E . C O M FRESNEL TCW/TWW User Manual THIS PAGE INTENTIONALLY BLANK 27 W W W.VAR I - L I T E . C O M TECHNICAL SUPPORT GLOBAL 24HR TECHNICAL SUPPORT: Call: +1 214 647 7880 entertainment.service@signify.com NORTH AMERICA SUPPORT: Call: 877-VARI-LITE (877-827-4583) entertainment.service@signify.com EUROPEAN CUSTOMER SERVICE CENTER: Call: +31 (0) 543 542 531 entertainment.europe@signify.com ©2024 Signify Holding. All rights reserved. All trademarks are owned by Signify Holding or their respective owners. The information provided herein is subject to change, without notice. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial o er and does not form part of any quotation or contract, unless otherwise agreed by Signify. Data subject to change. FRESNEL TCW/TWW User Manual VERSION DATE: MARCH 19, 2024