User Manual for Ruffneck models including: CX1 ProVector Series Explosion Proof Convection Heater, CX1 ProVector Series, Explosion Proof Convection Heater, Convection Heater, Heater
RuffneckTM CX1 ProVector Series Owner's Manual: For Installation, Maintenance, Repair, and Replacement Parts
6 gen 2023 — Read and follow all instructions in this manual. ... rated operating temperature, as shown on the heater data plate. ... Wire Connector, 302°F (150°C).
» CX1 — взрывобезопасный конвекционный обогреватель ProVector
File Info : application/pdf, 32 Pages, 4.07MB
DocumentDocumentWARNING! Read all important information notices on page 3. Please adhere to instruction published in this manual. Failure to do so may be dangerous and may void certain provisions of your warranty. ISO 9001 Electric Convection Air Heaters for Hazardous Locations CX1 ProVector® Series Installation, Operation, & Maintenance Instructions Model Coding CX1 - 120 1 60 - 012 - T2A IIB - T Model Series Heater Voltage 120 V, 208 V, 240 V, 277 V, 380 V, 400 V, 415 V, 480 V, 600 V Phase 1, 3 Hertz 50, 60 T-Code T2A - 536ºF (280ºC) T3 - 392ºF (200ºC) Hazardous Location IIB, IIC T Built-in room thermostat. Add `T' for T-stat. A Stainless steel cabinet 1st Generation Heater Kilowatts 0075 - 0.75 kW 0135 - 1.35 kW 0313 - 3.13 kW 048 - 4.8 kW 0747 - 7.47 kW 0083 - 0.83 kW 018 - 1.8 kW 0333 - 3.33 kW 050 - 5.0kW 076 - 7.6 kW 009 - 0.90 kW 0226 - 2.26 kW 0347 - 3.47 kW 0528 - 5.28 kW 100 - 10.0 kW 0113 - 1.13 kW 025 - 2.5 kW 0359 - 3.59 kW 0568 - 5.68 kW 012 - 1.2 kW 0269 - 2.69 kW 036 - 3.6 kW 0626 - 6.26 kW 0125 - 1.25 kW 0301 - 3.01 kW 0476 - 4.76 kW 0694 - 6.94 kW Reminder: This nomenclature illustration is intended primarily to explain how a product part number is defined. Not all voltages and/or wattage combinations are available. Please consult the Performance Data chart(s) for product availability. Approved Locations Electric convection air heaters are cULus listed for the following hazardous locations: (without built-in thermostat) Class I, Div. 1 & 2, Groups A, B, C & D Class I, Zones 1 &2, Groups IIA, IIB, IIC Temperature Code T2A 536°F (280°C), T3 392°F (200°C) (with built-in thermostat) Class I, Div. 1 & 2, Groups A, B, C &D Class I, Zones 1 &2, Groups IIA,IIB, IIC Temperature Code T2A 536°F (280°C), T3 392°F (200°C) For details of hazardous locations with potential for explosion, refer to the Canadian Electrical Code, Part 1, Section 18 or National Electrical Code Articles 500 - 516. RuffneckTM and ProVector® are registered trademarks of Themon. Copyright © 2023. All rights reserved. Part No. 6348.Rev.18.06 January 2023 Printed in Canada TABLE OF CONTENTS A. Heater Maintenance Checklist 3 A.1 Periodic.................................................................................................................................................. 3 A.2 Annual ................................................................................................................................................... 3 B. Important Notices 4 C. Installation 4 C.1 Mechanical ..........................................................................................................................................4 C.2 Electrical............................................................................................................................................... 7 D. Specifications 8 E. Parts Diagram 9 F. Parts List 10 G. Repair & Replacement 11 G.1 Finned Tube/Element Assembly............................................................................................11 G.2 Cabinet Panels and Brackets................................................................................................11 H. CX1 Technical Data 12 H.1 1-Phase ..................................................................................................................................................12 H.2 3-Phase............................................................................................................................................... 14 A. HEATER MAINTENANCE CHECKLIST Photocopy this page for reuse. WARNING. Disconnect heater from the power supply before opening enclosures or servicing heater. WARNING Lock the switch in the "OFF" (open) position and/or tag the switch to prevent unexpected power application. For heaters marked "IIC", ensure to loosen the setscrew before removing the cover. This heater should only be serviced by personnel with heating and hazardous location equipment experience. Heater Model Serial Number Comments Date of Maintenance Maintenance Done By A.1 Periodic (before and as required during heating season) Clean Finned Tubes Cabinet top and below unit Remove dust using compressed air. Do not spray with water or solvents. Do not immerse in water or solvents Check All explosion-proof covers for tightness. A.2 Annual (before heating season) Mechanical Check Check all enclosures. Inside of enclosures must be clean, dry, and free of foreign materials. Enclosure joints are metal to metal. Do not use gasket material or sealant in joints. Check the tightness of all hardware. All nuts and bolts must be tight. Turn heater on for a minimum of five minutes. Check for warm air exiting heater through top vents. Electrical Check Check all terminal connections and conductors. Tighten loose connections. Conductors with damaged insulation must be replaced. Check all explosion-proof conduits. Replace damaged conduits, unions, and plugs. Ensure 5 turns of engagement on all threaded connections. Heater Maintenance Checklist For assistance, please call Toll Free: 1-800-661-8529 (24 hrs) U.S. & Canada 3 B. IMPORTANT NOTICES 8. WARNING. Read and adhere to the following installation instructions. Failure to do so may result in WARNING severe or fatal injury and/or possible voiding of the warranty. 9. 1. Read and follow all instructions in this manual. 10. 2. Heater is to be used only in atmospheres having an ignition temperature higher than the heater's maximum rated operating temperature, as shown on the heater 11. data plate. Refer to applicable electrical codes for additional information. 3. Heater to be used only in the hazardous locations indicated on the heater data plate. 4. Heater is for dry, indoor use only. Do not immerse in water. 12. Do not store or use in areas exposed to rain or snow. 5. Maximum ambient operating temperature 104°F (40°C). 13. 6. Heater is to be connected and serviced only by a 14. qualified electrician experienced with hazardous location equipment. 15. 7. Installation and wiring of the heater must adhere to all applicable codes. 16. C. INSTALLATION Before opening any enclosures, disconnect the heater from the power supply. Lock the switch in the "OFF" (open) position and/or tag the switch to prevent unexpected power application. External surfaces get hot and can cause burns with prolonged contact. Operate the heater only while it is permanently mounted in an upright position. Refer to the C.1 Mechanical, page 4 for details. Heater must be kept clean. When operating in a dirty environment, regularly clean the finned tubes, top vents, and keep bottom opening free of obstructions. Follow the recommended maintenance procedures. Refer Section A. Heater Maintenance Checklist, page 3 for details. Do not operate the heater in atmosphere corrosive to steel or aluminum. Use factory approved replacement parts only. Conduit seals are not required in the heater's factory installed conduits. A conduit seal is required within 6" (153 mm) of field entries. If there are any questions or concerns regarding the heater, contact the factory. Refer to the last page of this manual for details. All applicable codes must be adhered to. For optimum heating, the heater should be installed as follows: C.1 Mechanical 1. Location 2.4 After mounting brackets are secured, tilt the heater and lower it onto the top tabs of the mounting bracket such that the tabs go into the mounting slots on the rear panel of the heater cabinet (Figure 2, page 5). 1.1 The air discharge is not directed at a thermostat. 1.2 The air discharge is across areas of heat loss, such as windows. 1.3 If equipment freeze protection is of importance, locate heater as close to equipment as possible. 2. Mounting 2.1 Heater must be mounted level on a vertical surface using the factory supplied mounting brackets such that there are no obstructions to impede air inlet or discharge. 2.2 The mounting surface must be strong enough to: Support the heater's weight, refer to Section D. Specifications, page 8. Withstand abusive situations such as transportable installations of the heater. 1.5" 2.3 Secure mounting brackets to vertical surface with (38.0 mm) the top mounting hole 1.5" (38 mm) below the desired top surface height (Figure 1, page 4). Refer to Figure 3, page 5, Figure 4 and Figure 5, page 4 for physical dimensions and Figure 5, page 6 for required installation clearances. Figure 1 Mounting brackets are to be spaced to match the 4 slots in the rear panel of heater cabinet. Important Notices / Installation 2.5 Carefully swing the bottom of the heater into the mounting brackets so that it is resting on the bottom tab (Figure 2, page 5). 2.6 Insert the securing screw through the bottom mounting bracket tab and into the cabinet to keep the heater from dislodging from the mounting bracket (Figure 2, page 5). 2.7 Caution: Use fasteners with yield stress greater than or equal to 58 ksi (400 MPa). Mounting bracket Top tab detail Group B, C, D, Heaters with Defender® Housing Figure 2 Securing screw Bottom tab detail Heater kW Rating 'A' Dimension 'C' Dimension 'B' Dimension w/o Extension w/ Extension w/o Extension w/ Extension in mm in mm in mm in mm in mm 0.75 to 2.69 & 3.6 (T2A) 3.01 to 3.59, 3.6 (T3) & 4.8 4.76, 5.28 to 7.6* 3.13, 3.47, 3.74, 5.0, 6.26, 6.94, 7.47 & 10.0 36.9 938 39.0 991 31.34 796 55.0 1398 57.1 1451 49.45 1256 65.1 1653 67.2 1706 59.49 1511 5.6 142 7.7 195 77.4 1965 79.4 2018 71.78 1823 * Except 7.6 kW, 208, 3Ø and 10 kW, 208V, & 277V, 3Ø units ** 1Ø Thermostat units require extension Figure 3 Physical Dimensions 5 Installation Group A,B,C,D Heater with x-Max® Housing Heater kWRating 0.75 to 2.69 & 3.6 (T2A) 3.01 to 3.59, 3.6 (T3) & 4.8 'D' Dimension 1Ø w/o Extension 1Ø* w/ Extension 3Ø Units in mm in mm in mm 'B' Dimension in mm 37.6 954 39.6 1007 38.3 973 31.34 796 55.7 1414 57.8 1467 56.4 1433 49.45 1256 4.76, 5.28 to 7.6* 65.7 1669 67.8 1722 66.5 1688 59.49 1511 3.13, 3.47, 3.74, 5.0, 6.26, 6.94, 7.47 & 10.0 78.0 1981 80.1 * 1Ø Thermostat units require extension 2034 78.7 2000 71.78 1823 'E' Dimension w/o Extension w/ Extension 3Ø Units in mm in mm in mm 6.2 158 8.3 211 7.0 177 Figure 4 Physical Dimensions Minimum 18" (457 mm) Minimum 0.375" (9.5 mm) 48" (1219 mm) Required for ease of installation and servicing Minimum 8.0" (203 mm) Floor Figure 5 Installation Clearances Minimum 0.375" (9.5 mm) Wall 12" (305 mm) Required for ease of installation 6 Installation C.2 Electrical WARNING. Disconnect the power supply before installation of the heater. WARNING Lock the switch in the "OFF" (open) position and/ or tag the switch to prevent unexpected power application. For heaters marked "IIC", insure to loosen the setscrew before removing the cover. Installation and wiring of the heater must adhere to all applicable codes. 1. General 1.1 Use only copper conductors and approved explosion-proof wiring methods during installation. Refer to the Section H.1 1-Phase, page 12 and Section H.2 3-Phase, page 14, or heater data plate for the voltage, amperage and wattage ratings when sizing for the appropriate conductors. All supply conductors should be rated for operating at temperatures up to 194°F (90°C). 1.2 Supply voltage must be within 10% of the data plate rating. External over-current protection is required and must meet data plate ratings for voltage, amperage and frequency. 2. Field Wiring Heater has been supplied with an enclosure that has a 3/4" NPT or 1" NPT threaded opening to accommodate the line conductors (see Figure 3, page 5 to for connection details). Use wire connectors rated for minimum 194°F (90°C). NOTE: If remote thermostats other than the factory supplied are used, ensure that they will not allow the room temperature to exceed ambient temperature limitations of the heater (104°F/40°C) and are suitable for the area's hazardous atmosphere classification. When using any control devices, ensure that the voltage and amperage ratings match the heater's electrical ratings. If not, a contactor may be required. 3. Final Inspection 3.1 Before application of electrical power: Check that all connections are secured and comply with the wiring diagram (see Figure 6 and Figure 7, page 7 and applicable code requirements, Confirm that the supply voltage and phase is compatible with the data plate specifications, Remove any foreign objects from the heater, and Ensure all external fittings and enclosure covers are secured. Element L1* L2 Element Room Thermostat * On 120V units L1 represents neutral Figure 6 Wiring Diagram for remote mount and built-in room thermostats (1Ø units) DPST Room Thermostat L1 L2 L3 Elements GND Figure 7 Wiring Diagram for remote mount and built-in room thermostats (3Ø units) Installation 7 D. SPECIFICATIONS Cabinet Length Net Weight Shipping Weight in mm lbs kg lbs kg 0.75 - 2.69 & 3.6 (T2A) 31.3 796 55.3 25.1 65 30 Nominal kW 3.01, 3.33, 3.59, 3.6 (T3), 4.8 4.76, 5.28, 5.68, 7.6 49.4 59.5 1256 1511 80.7 92.8 36.6 42.1 95 105 44 47.6 3.13, 3.47, 3.74, 5.0, 6.26, 6.94, 7.47, 10.0 71.8 1823 117 53.2 142 65.5 SpecificationsforModels 1. Hazardous Locations 2. Enclosures 3. Mounting Brackets Without Built-in T'Stat* Class I, Div. 1 & 2, Groups B, C, & D; Zones 1 & 2, Groups IIA, IIB + H2 (Defender® Housing)or, Class I, Div. 1 & 2, Groups A, B, C, & D, Groups IIA, IIB, IIC (x-Max®) With Built-in T'Stat* Class I, Div. 1 & 2, Groups C, & D, Zones 1 &2, Groups IIA, IIB (Defender® Housing) or, Class I, Div. 1 & 2, Groups A, B, C, D, Zones 1 & 2, Groups IIA, IIB. IIC ( x-Max® housing) Defender® housing is cast aluminum with bolt on cover, Groups IIB. x-Max® housing is extruded aluminum with two screwed on covers. The x-Max® housing offers IP55 moisture ingress protection, Groups IIC. For dry indoor use only. Do not immerse in water. Do not store or use in areas exposed to rain or snow. Two 14 Ga. (0.075 in) (1.90 mm) galvanized steel. 4. Heating Elements 5. Cabinet Material 6. Temperature Code Rating 7. Temperature Limitations Incoloy® sheathed elements. 14 Ga. steel. Rear panel is galvanized. Front and side panels are baked greengrey epoxy powder coated with five-stage pretreatment, including iron phosphate. T2A 536°F (280°C), T3 392°F (200°C) Operational: -49°F to 104°F Storage: -49°F to 176°F *Hazardous location ratings are dependant on the junction box used. Please consult a customer service representative or the unit data plate for actual location ratings. Specifications 8 E. PARTS DIAGRAM 8 2 PLCS 4 2 PLCS 9 11 2 PLCS 10 5 1 6 General Assembly Screw 16 2 3 8 C2 C1 See t'stat options 7 IIB, Built-in T'stat Option 19 14 IIB + H2 Without T'stat Option 9 IIC, Built-in T'stat Option 9 IIC, Without Built-in T'stat Option 9 9 13 12 19 19 21 20 1-Phase Wiring Conduit Detail 18 IIB Built-in Wiring 15 16 GND Wire IIB+H2 Without T'stat Wiring IIC Built-in T'stat Wiring 15 2 PLCS 16 GND Wire IIC Without T'stat Wiring 2 PLCS 17 Connect to "common" and "norm closed" terminals of built-in T'stat. 17 2 PLCS 15 2 PLCS GND Wire 3-Phase Wiring Conduit Detail IIB+H2 Without T'stat Wiring IIC Without T'stat Wiring IIC Built-in T'stat Wiring 15 3 PLCS 16 GND Wire 18 15 3 PLCS GND Wire 9 Parts Diagram F. PARTS LIST Please have model and serial number available before calling. Item No. Description 1 Panel, Front 2 Panel, Back Panel, Right - 1Ø units 3 Panel, Right - 3Ø units 4 Panel, Left Bracket, Finned Tube - 1Ø units 5 Bracket, Finned Tube - 3Ø units 6 Kit, Wall Mounting 7 Finned Tube Assy c/w Element Nut, 3/4 Alum. Lock - 1Ø units 8 Nut, 1" NPT Lock - 3Ø units Union, 3/4 NPT Male/Female - 1Ø units 9 Union, 1" NPT Female/Female - 3Ø units Union, 1" NPT Male/Female - 3Ø units 10 Conduit, Element 11 Plug, 3/4 Ex-Proof 12 Kit, Group B, (IIB +H2) Enclosure 13 Enclosure,Convector 14 Kit, Built-in XCT T'Stat - 1Ø units 15 Wire Connector, 302°F (150°C) 16 Screw, 10-24 x 1/2 in. Thd Ct 17 Fork Connector, 12-10GA #10 18 Wire Connector, 572°F (300°C) 19 Tube Extension - 1Ø units 20 Kit, Built-in XT T'Stat - 1Ø units 21 Kit, Built-in XT T'Stat - 3Ø units 22 Reducer Bushing - 3Ø units 23 Nipple - 3Ø units 24 Reducer, 3/4 x 1" Male/Female 31.5" (796 mm) Part No. 6488 6487 6491 12304 6492 6485 12303 6602 * 6449 12676 6506 12677 12787 6497 1443 6604 6211 6603 Qty. 1 1 1 1 1 1 1 1 2 4 4 4 2 2 1 2 1 1 1 4972 20 2088 2 6529 + 7202 2 11773 1 13728 1 12679 2 12678 2 12867 2 Cabinet Length 49.4" (1256 mm) 59.5" (1511 mm) Part No. 6493 6494 6491 12304 6492 6485 12303 6602 * 6449 12676 6506 12677 12787 6497 1443 6604 6211 6603 4972 2088 6529 7202 11773 13728 12679 12678 12867 Qty. Part No. 1 6490 1 6489 1 6491 1 12304 1 6492 1 6485 1 12303 1 6602 2 * 4 6449 4 12676 4 6506 2 12677 2 12787 1 6497 2 1443 1 6604 1 6211 1 6603 ** 21 4972 2 2088 + 6529 2 7202 1 11773 1 13728 2 12679 2 12678 2 12867 Qty. 1 1 1 1 1 1 1 1 2 4 4 4 2 2 1 2 1 1 1 22 2 + 2 1 1 2 2 2 71.78" (1823 mm) Part No. 12305 12306 6491 12304 6492 6485 12303 6602 * 6449 12676 6506 12677 12787 6497 1443 6604 6211 6603 Qty. 1 1 1 1 1 1 1 1 2 4 4 4 2 2 1 2 1 1 1 4972 24 2088 2 6529 + 7202 2 11773 1 13728 1 12679 2 12678 2 12867 2 NOTE: * Contact factory for replacement finned tube kits. ** Customer supplied. Quantity varies: 1 for built-in T'stat option; 2 for remote T'stat option. + Quantity varies: 1 for 1Ø, 2 for 3Ø Parts Diagram 10 G. REPAIR & REPLACEMENT WARNING WARNING. Disconnect the power supply before installation of the heater. Lock the switch in the "OFF" (open) position and/or tag the switch to prevent unexpected power application. Heater surfaces may be hot. G.1 Finned Tube/Element Assembly A complete finned tube assembly is available from the factory. Refer to Section E. Parts Diagram, page 9 for item numbers. 1. Remove the front cabinet panel (Item #1). 2. Remove convector enclosure's cover and disconnect wires. 3. De-couple two unions (Item #9) connecting convector enclosure and finned tube extrusion (Item #7). 4. Remove the front 3/4" NPT plug (Item #11) from element conduit (Item #10) and then pull out wire connector and disconnect the wires. 5. De-couple remaining two unions and remove element conduit. 6. Remove union halves and lock-nut (Item #8) from ends of each finned tube requiring replacement and set aside for re-use on new factory supplied finned/element assemblies. 7. Remove bolts from lower tabs of wall mount brackets (Item #6), remove heater from wall mount brackets, and loosen the bolts from the finned tube bracket (Item #5). 8. Remove the damaged finned tube/element assemblies and install replacements. 9. Re-assemble heater using the reverse order of the preceding instructions. IMPORTANT: All threaded connections must be wrench tight with a minimum of 5 turns engagement. G.2 Cabinet Panels and Brackets Replacement cabinet panels and brackets are available from the factory. NOTE: For purposes of safety and convenience, all repairs and maintenance must be done with factory authorized parts and materials. Repair & Replacement 11 H. CX1 TECHNICAL DATA H.1 1-Phase Gas Group Uni t Voltage Suppl y Wire Size *** Uni t Current Max. Circuit Fuse* Cabinet Length Temperature Code Model kW (Btu/ hr) V CX1-120160-012-T3 CX1-120160-018-T3 CX1-208160-012-T3 CX1-208160-018-T3 CX1-208160-036-T3** CX1-208160-048-T2A CX1-208160-050-T3 CX1-208160-076-T2A CX1-240160-012-T3 CX1-240160-018-T3 CX1-240160-036-T3** CX1-240160-048-T2A CX1-240160-050-T3 CX1-240160-076-T2A CX1-277160-012-T3 CX1-277160-018-T3 CX1-277160-036-T3** CX1-277160-048-T2A CX1-277160-050-T3 CX1-277160-076-T2A CX1-380160-0075-T3 CX1-380160-0113-T3 CX1-380160-012-T3 CX1-380160-018-T3 CX1-380160-0226-T2A CX1-380160-0301-T3 CX1-380160-0313-T3 CX1-380160-036-T3** CX1-380160-0476-T2A CX1-380160-048-T2A CX1-380160-050-T3 CX1-380160-0626-T2A CX1-380160-076-T2A CX1-380160-100-T2A CX1-400160-0083-T3 CX1-400160-012-T3 1.2 (4095) 1.8 (6142) 1.2 (4095) 1.8 (6142) 3.6 (12284) 4.8 (16378) 5.0 (17060) 7.6 (25932) 1.2 (4095) 1.8 (6142) 3.6 (12284) 4.8 (16378) 5.0 (17060) 7.6 (25932) 1.2 (4095) 1.8 (6142) 3.6 (12284) 4.8 (16378) 5.0 (17060) 7.6 (25932) 0.75 (2560) 1.13 (3856) 1.2 (4095) 1.8 (6142) 2.26 (7711) 3.01 (10271) 3.13 (10680) 3.6 (12284) 4.76 (16241) 4.8 (16378) 5.0 (17060) 62.6 (21360) 7.6 (25932) 10.0 (34121) 0.83 (2832) 1.2 (4095) 120 120 208 208 208 208 208 208 240 240 240 240 240 240 277 277 277 277 277 277 380 380 380 380 380 380 380 380 380 380 380 380 380 380 400 400 IIB + H2 IIB IIC w/o T'stat w/ T'stat N/A N/A N/A N/A N/A N/A w/o T'stat w/ T'stat N/A N/A N/A N/A N/A N/A AWG 12 12 12 12 12 8 8 8 12 12 12 10 8 8 12 12 12 12 8 8 12 12 12 12 12 12 12 12 10 10 10 8 8 8 12 12 A 10.0 15.0 5.8 8.7 17.3 23.1 24.0 36.5 5.0 7.5 15.0 20.0 20.8 31.7 4.3 6.5 13.0 17.3 18.1 27.4 2.0 3.0 3.2 4.7 5.9 7.9 8.2 9.5 12.5 12.6 13.2 16.5 20.0 26.3 2.1 3.0 A in (mm) 15 31.3 (796) T3 (200) 20 31.3 (796) T3 (200) 15 31.3 (796) T3 (200) 15 31.3 (796) T3 (200) 25 49.5 (1256) T3 (200) 30 49.5 (1256) T2A (280) 30 71.8 (1823) T3 (200) 50 59.5 (1511) T2A (280) 15 31.3 (796) T3 (200) 15 31.3 (796) T3 (200) 20 49.5 (1256) T3 (200) 25 49.5 (1256) T2A (280) 30 71.8 (1823) T3 (200) 40 59.5 (1511) T2A (280) 15 31.3 (796) T3 (200) 15 31.3 (796) T3 (200) 20 49.5 (1256) T3 (200) 25 49.5 (1256) T2A (280) 25 71.8 (1823) T3 (200) 35 59.5 (1511) T2A (280) 15 31.3 (796) T3 (200) 15 31.3 (796) T3 (200) 15 31.3 (796) T3 (200) 15 31.3 (796) T3 (200) 15 31.3 (796) T2A (280) 15 49.5 (1256) T3 (200) 15 71.8 (1823) T3 (200) 15 49.5 (1256) T3 (200) 20 59.5 (1511) T2A (280) 20 49.5 (1256) T2A (280) 20 71.8 (1823) T3 (200) 25 71.8 (1823) T2A (280) 25 59.5 (1511) T2A (280) 35 71.8 (1823) T2A (280) 15 31.3 (796) T3 (200) 15 31.3 (796) T3 (200) Notes * Or equivalent breaker as per local electrical inspection authority requirements. ** For 3.6 kW heaters rated T3 cabinet length is 49.5" (1256 mm). 3.6 kW heaters rated T2A cabinet length is 31.3" (796 mm). *** Ensure supply wire size adheres to applicable local and national electrical codes. 1. Heater is functioning normally if, at rated voltage, the current draw is within 10% of the value in this table. 2. Operation at lower voltages that rated will result in reduced output and current draw. 3. Actual Output (kW) = [(Supply Voltage)2 ÷ (Rated Voltage)2] × Rated Unit Wattage (kW)] 4. Add suffix "T" for optional built-in thermostat. Thermostat not available on IIB+H2 models. 1-Phase CX1 Technical Data 12 Uni t Voltage Suppl y Wire Size *** Uni t Current Max. Circuit Fuse* Cabinet Length Temperature Code Gas Group Model kW (Btu/ hr) V CX1-400160-0125-T3 1.25 (4565) CX1-400160-018-T3 1.8 (6142) CX1-400160-025-T2A 2.5 (8530) CX1-400160-0333-T3 3.33 (11362) CX1-400160-0347-T3 3.47 (11840) CX1-400160-036-T3** 3.6 (12284) CX1-400160-048-T2A 4.8 (16378) CX1-400160-050-T3 5.0 (17060) CX1-400160-0528-T2A 5.28 (18016) CX1-400160-0694-T3 6.94 (23680) CX1-400160-076-T2A 7.6 (25932) CX1-400160-100-T2A 10.0 (34121) CX1-415160-009-T3 0.9 (3071) CX1-415160-012-T3 1.2 (4095) CX1-415160-0135-T3 1.35 (4606) CX1-415160-018-T3 1.8 (6142) CX1-415160-0269-T2A 2.69 (9179) CX1-415160-0359-T3 3.59 (12250) CX1-415160-036-T3** 3.6 (12284) CX1-415160-0374-T3 3.74 (12761) CX1-415160-048-T2A 4.8 (16378) CX1-415160-050-T3 5.0 (17060) CX1-415160-0568-T2A 5.68 (19381) CX1-415160-0747-T2A 7.47 (25488) CX1-415160-076-T2A 7.6 (25932) CX1-415160-100-T2A 10.0 (34121) CX1-480160-012-T3 1.2 (4095) CX1-480160-018-T3 1.8 (6142) CX1-480160-036-T3** 3.6 (12284) CX1-480160-048-T2A 4.8 (16378) CX1-480160-050-T3 5.0 (17060) CX1-480160-076-T2A 7.6 (25932) CX1-480160-100-T2A 10.0 (34121) CX1-600160-012-T3 1.2 (4095) CX1-600160-018-T3 1.8 (6142) CX1-600160-036-T3** 3.6 (12284) CX1-600160-048-T2A 4.8 (16378) CX1-600160-050-T3 5.0 (17060) CX1-600160-076-T2A 7.6 (25932) CX1-600160-100-T2A 10.0 (34121) 400 400 400 400 400 400 400 400 400 400 400 400 415 415 415 415 415 415 415 415 415 415 415 415 415 415 480 480 480 480 480 480 480 600 600 600 600 600 600 600 IIB + H2 IIB IIC w/o T'stat w/ T'stat N/A N/A N/A N/A N/A N/A N/A N/A N/A w/o T'stat w/ T'stat N/A N/A N/A N/A N/A N/A N/A N/A N/A AWG 12 12 12 12 12 12 10 10 10 8 8 8 12 12 12 12 12 12 12 12 10 10 10 8 8 8 12 12 12 12 12 10 8 12 12 12 12 12 12 10 A 3.1 4.5 6.3 8.3 8.7 9.0 12.0 12.5 13.2 17.4 19.0 25.0 2.2 2.9 3.3 4.3 6.5 8.7 8.7 9.0 11.6 12.0 13.7 18.0 18.3 24.1 2.5 3.8 7.5 10.0 10.4 15.8 20.8 2.0 3.0 6.0 8.0 8.3 12.7 16.7 A in (mm) 15 31.3 (796) T3 (200) 15 31.3 (796) T3 (200) 15 31.3 (796) T2A (280) 15 49.5 (1256) T3 (200) 15 71.8 (1823) T3 (200) 15 49.5 (1256) T3 (200) 15 49.5 (1256) T2A (280) 20 71.8 (1823) T3 (200) 20 59.5 (1511) T2A (280) 25 71.8 (1823) T3 (200) 30 59.5 (1511) T2A (280) 35 71.8 (1823) T2A (280) 15 31.3 (796) T3 (200) 15 31.3 (796) T3 (200) 15 31.3 (796) T3 (200) 15 31.3 (796) T3 (200) 15 31.3 (796) T2A (280) 15 49.5 (1256) T3 (200) 15 49.5 (1256) T3 (200) 15 71.8 (1823) T3 (200) 15 49.5 (1256) T2A (280) 15 71.8 (1823) T3 (200) 20 59.5 (1511) T2A (280) 25 71.8 (1823) T2A (280) 25 59.5 (1511) T2A (280) 35 71.8 (1823) T2A (280) 15 31.3 (796) T3 (200) 15 31.3 (796) T3 (200) 15 49.5 (1256) T3 (200) 15 49.5 (1256) T2A (280) 15 71.8 (1823) T3 (200) 20 59.5 (1511) T2A (280) 30 71.8 (1823) T2A (280) 15 31.3 (796) T3 (200) 15 31.3 (796) T3 (200) 15 49.5 (1256) T3 (200) 15 49.5 (1256) T2A (280) 15 71.8 (1823) T3 (200) 20 59.5 (1511) T2A (280) 25 71.8 (1823) T2A (280) 5. Add suffix "H" for high-temperature ambient storage option. High temperature storage option is not available with thermostat option. Not available on IIB models. 6. For IIB model with Defender® built-in thermostat - Class I, Div. 1 & 2, Groups C & D; Zones 1 & 2, Groups IIA and IIB. 7. For IIC model with XT built-in thermostat - Class I, Div. 1 & 2, Groups A,B,C & D; Zones 1 & 2, Groups IIA, IIB, IIC. 8. IIC Grouping units come with x-Max® housing. 9. Remote mounted, Defender, explosion-proof room thermostats are not suitable for Group B & IIC applications. 10. Remote contactors are required on all 600V heaters, and heaters with a current draw greater than 22 amps (supplied & installed by others), when utilizing XT-311 remote thermostat. 11. Temperature code ratings: T2A - 280°C (536°F), T3 - 200°C (392°F) 1-Phase CX1 Technical Data 13 Uni t Voltage Suppl y Wire Size *** Uni t Current Max. Circuit Fuse* Cabinet Length Temperature Code H.2 3-Phase Model CX1-208360-012-T3 CX1-208360-018-T3 CX1-208360-036-T3** CX1-208360-048-T2A CX1-208360-050-T3 CX1-208360-076-T2A CX1-208360-100-T2A CX1-240360-012-T3 CX1-240360-018-T3 CX1-240360-036-T3** CX1-240360-048-T2A CX1-240360-050-T3 CX1-240360-076-T2A CX1-240360-100-T2A CX1-277360-012-T3 CX1-277360-018-T3 CX1-277360-036-T3** CX1-277360-048-T2A CX1-277360-050-T3 CX1-277360-076-T2A CX1-277360-100-T2A CX1-380360-0113-T3 CX1-380360-0226-T2A CX1-380360-0301-T3 CX1-380360-0313-T3 CX1-380360-0476-T2A CX1-380360-050-T3 CX1-380360-0626-T2A CX1-380360-100-T2A CX1-400360-0125-T3 Gas Group kW (Btu/hr) IIB + H2 IIB IIC 1.2 (4095) 1.8 (6142) 3.6 (12284) 4.8 (16378) 5.0 (17060) 7.6 (25932) 10.0 (34121) 1.2 (4095) 1.8 (6142) V w/o w/ w/o w/ T'stat T'stat T'stat T'stat AWG 208 12 208 12 208 12 208 10 208 10 208 N/A 8 208 N/A 8 240 12 240 12 3.6 (12284) 240 12 4.8 (16378) 240 12 5.0 (17060) 240 12 7.6 (25932) 240 10 10.0 (34121) 240 N/A N/A 8 1.2 (4095) 277 12 1.8 (6142) 277 12 3.6 (12284) 277 12 4.8 (16378) 277 12 5.0 (17060) 277 12 7.6 (25932) 277 10 10.0 (34121) 277 N/A 8 1.13 (3856) 380 12 2.26 (7711) 380 12 3.01 (10271) 380 12 3.13 (10680) 380 12 4.76 (16241) 380 12 5.0 (17060) 380 12 6.26 (21360) 380 12 10.0 (34121) 380 10 1.25 (4565) 400 12 A 3.3 5.0 10.0 13.3 13.9 21.1 27.8 2.9 4.3 8.7 11.5 12.0 18.3 24.1 2.5 3.8 7.5 10.0 10.4 15.8 20.8 1.7 3.4 4.6 4.8 7.2 7.6 9.5 15.2 1.8 A in (mm) 15 31.3 (796) T3 (200) 15 31.3 (796) T3 (200) T3 (200) 15 49.5 (1256) 10 20 49.5 (1256) T2A (280) 20 71.8 (1823) T3 (200) 30 59.5 (1511) T2A (280) 35 71.8 (1823) T2A (280) 15 31.3 (796) T3 (200) 15 31.3 (796) T3 (200) T3 (200) 15 49.5 (1256) 12 20 49.5 (1256) T2A (280) 15 71.8 (1823) T3 (200) 25 59.5 (1511) T2A (280) 35 71.8 (1823) T2A (280) 15 31.3 (796) T3 (200) 15 31.3 (796) T3 (200) T3 (200) 15 49.5 (1256) 10 15 49.5 (1256) T2A (280) 15 71.8 (1823) T3 (200) 20 59.5 (1511) T2A (280) 30 71.8 (1823) T2A (280) 15 31.3 (796) T3 (200) 15 31.3 (796) T2A (280) 15 49.5 (1256) T3 (200) 15 71.8 (1823) T3 (200) 15 59.5 (1511) T2A (280) 15 71.8 (1823) T3 (200) 15 71.8 (1823) T2A (280) 20 71.8 (1823) T2A (280) 15 31.3 (796) T3 (200) 3-Phase CX1 Technical Data Notes * Or equivalent breaker as per local electrical inspection authority requirements. ** For 3.6 kW heaters rated T3 cabinet length is 49.5" (1256 mm). 3.6 kW heaters rated T2A cabinet length is 31.3" (796 mm). *** Ensure supply wire size adheres to applicable local and national electrical codes. · Available for IIB only. 1. Heater is functioning normally if, at rated voltage, the current draw is within 10% of the value in this table. 2. Operation at lower voltages that rated will result in reduced output and current draw. 3. Actual Output (kW) = [(Supply Voltage)2 ÷ (Rated Voltage)2] × Rated Unit Wattage (kW)] 4. Add suffix "T" for optional built-in thermostat. Thermostat not available on IIB+H2 models. 14 Uni t Voltage Suppl y Wire Size *** Uni t Current Max. Circuit Fuse* Cabinet Length Temperature Code Model kW (Btu/hr) Gas Group IIB + H2 IIB IIC V w/o w/ w/o w/ T'stat T'stat T'stat T'stat AWG A CX1-400360-025-T2A 2.5 (8530) 400 12 3.6 CX1-400360-0333-T3 3.33 (11362) 400 12 4.8 CX1-400360-0347-T3 3.47 (11840) 400 CX1-400360-050-T3 5.0 (17060) 400 CX1-400360-0528-T2A 5.28 (18016) 400 CX1-400360-0694-T2A 6.94 (23680) 400 CX1-400360-100-T2A 10.0 (34121) 400 CX1-415360-0135-T3 1.35 (4606) 415 CX1-415360-0269-T2A 2.69 (9179) 415 CX1-415360-0359-T3 3.59 (12250) 415 CX1-415360-0374-T3 3.74 (12761) 415 CX1-415360-050-T3 5.0 (17060) 415 CX1-415360-0568-T2A 5.68 (19381) 415 CX1-415360-0747-T2A 7.47 (25488) 415 12 5.0 12 7.2 12 7.6 12 10.0 10 14.4 12 1.9 12 3.7 12 5.0 12 5.2 12 7.0 12 7.9 12 10.4 CX1-415360-100-T2A 10.0 (34121) 415 N/A 10 13.9 CX1-480360-018-T3 1.8 (6142) 480 12 2.2 CX1-480360-036-T3** 3.6 (12284) 480 12 4.3 CX1-480360-048-T2A 4.8 (16378) 480 CX1-480360-050-T3 5.0 (17060) 480 CX1-480360-076-T2A 7.6 (25932) 480 CX1-480360-100-T2A 10.0 (34121) 480 12 5.8 12 6.0 12 9.1 12 12.0 CX1-600360-036-T3** 3.6 (12284) 600 CX1-600360-048-T2A 4.8 (16378) 600 CX1-600360-050-T3 5.0 (17060) 600 CX1-600360-076-T2A 7.6 (25932) 600 CX1-600360-100-T2A 10.0 (34121) 600 12 3.5 12 4.6 12 4.8 12 7.3 12 9.6 A in (mm) 15 31.3 (796) T2A (280) 15 49.5 (1256) T3 (200) 15 71.8 (1823) T3 (200) 15 71.8 (1823) T3 (200) 15 59.5 (1511) T2A (280) 15 71.8 (1823) T3 (200) 20 71.8 (1823) T2A (280) 15 31.3 (796) T3 (200) 15 31.3 (796) T2A (280) 15 49.5 (1256) T3 (200) 15 71.8 (1823) T3 (200) 15 71.8 (1823) T3 (200) 15 59.5 (1511) T2A (280) 15 71.8 (1823) T2A (280) 20 71.8 (1823) T2A (280) 15 31.3 (796) T3 (200) T3 (200) 15 49.5 (1256) T2A (280) 15 49.5 (1256) T2A (280) 15 71.8 (1823) T3 (200) 15 59.5 (1511) T2A (280) 15 71.8 (1823) T2A (280) T3 (200) 15 49.5 (1256) T2A (280) 15 49.5 (1256) T2A (280) 15 71.8 (1823) T3 (200) 15 59.5 (1511) T2A (280) 15 71.8 (1823) T2A (280) 3-Phase CX1 Technical Data 5. Add suffix "H" for high-temperature ambient storage option. High temperature storage option is not available with thermostat option. Not available on IIB models. 6. For IIB model with Defender® built-in thermostat - Class I, Div. 1 & 2, Groups C & D; Zones 1 & 2, Groups IIA and IIB. 7. For IIC model with XT built-in thermostat - Class I, Div. 1 & 2, Groups A,B,C & D; Zones 1 & 2, Groups IIA, IIB, IIC. 8. IIC Grouping units come with X-MAX® housing. 9. Remote mounted, Defender®, explosion-proof room thermostats are not suitable for Group B & IIC applications. 10. Remote contactors are required on all 600V heaters, and heaters with a current draw greater than 22 amps (supplied & installed by others), when utilizing XT-311 remote thermostat. 11. Temperature code ratings: T2A - 280°C (536°F), T3 - 200°C (392°F) 15 PLEASE ADHERE TO INSTRUCTIONS IN THIS MANUAL Failure to do so may be dangerous and may void certain provisions of your warranty. For further assistance, please call 24hr hotline: 1-800-661-8529 (U.S.A. and Canada) Please have model and serial numbers available before calling. WARRANTY: Under normal use the Company warrants to the purchaser that defects in material or workmanship will be repaired or replaced without charge for a period of 18 months from date of shipment, or 12 months from the start date of operation, whichever expires first. Any claim for warranty must be reported to the sales office where the product was purchased for authorized repair or replacement within the terms of this warranty. Subject to State or Provincial law to the contrary, the Company will not be responsible for any expense for installation, removal from service, transportation, or damages of any type whatsoever, including damages arising from lack of use, business interruptions, or incidental or consequential damages. The Company cannot anticipate or control the conditions of product usage and therefore accepts no responsibility for the safe application and suitability of its products when used alone or in combination with other products. Tests for the safe application and suitability of the products are the sole responsibility of the user. This warranty will be void if, in the judgment of the Company, the damage, failure or defect is the result of: · Vibration, radiation, erosion, corrosion, process contamination, abnormal process conditions, temperature and pressures, unusual surges or pulsation, fouling, ordinary wear and tear, lack of maintenance, incorrectly applied utilities such as voltage, air, gas, water, and others or any combination of the aforementioned causes not specifically allowed for in the design conditions or, · Any act or omission by the Purchaser, its agents, servants or independent contractors which for greater certainty, but not so as to limit the generality of the foregoing, includes physical, chemical or mechanical abuse, accident, improper installation of the product, improper storage and handling of the product, improper application or the misalignment of parts. No warranty applies to paint finishes except for manufacturing defects apparent within 30 days from the date of installation. The Company neither assumes nor authorizes any person to assume for it any other obligation or liability in connection with the product(s). The Purchaser agrees that all warranty work required after the initial commissioning of the product will be provided only if the Company has been paid by the Purchaser in full accordance with the terms and conditions of the contract. The Purchaser agrees that the Company makes no warranty or guarantee, express, implied or statutory, (including any warranty of merchantability or warranty of fitness for a particular purpose) written or oral, of the Article or incidental labour, except as is expressed or contained in the agreement herein. LIABILITY: Technical data contained in the catalog or on the website is subject to change without notice. The Company reserves the right to make dimensional and other design changes as required. The Purchaser acknowledges the Company shall not be obligated to modify those articles manufactured before the formulation of the changes in design or improvements of the products by the Company. The Company shall not be liable to compensate or indemnify the Purchaser, end user or any other party against any actions, claims, liabilities, injury, loss, loss of use, loss of business, damages, indirect or consequential damages, demands, penalties, fines, expenses (including legal expenses), costs, obligations and causes of action of any kind arising wholly or partly from negligence or omission of the user or the misuse, incorrect application, unsafe application, incorrect storage and handling, incorrect installation, lack of maintenance, improper maintenance or improper operation of products furnished by the Company. Visit www.thermon.com to contact a Thermon representative near you. HEAD OFFICE: 7171 SOUTHWEST PKWY | BUILDING 300 SUITE 200 | AUSTIN, TX | 78735 | UNITED STATES RUFFNECK: 5918 ROPER ROAD | EDMONTON, AB | T6B-3E1 | CANADA AVERTISSEMENT! Lire tous les avis importants de la page 3. Respecter les directives du présent guide pour éviter tout danger ainsi que l'annulation de certaines dispositions de la garantie. ISO 9001 Réchauffeurs d'air à convection électrique pour les emplacements dangereux Série CX1 ProVector® Ce guide traite de l'installation, de la maintenance, de la réparation et des pièces. Code du modèle CX1 - 120 1 60 - 012 - T2A I I B - T Série du modèle Tension Fréquence 120 V, 208 V, 50, 60 240 V, 277 V, 380 V, 400 V, 415 V, 480 V, 600 V Phase 1, 3 T-Code T2A - 536ºF (280ºC) T3 - 392ºF (200ºC) T Thermostat intégrè. Ajouter `T' pour thermostat. Emplacement dangereux IIB, IIC 1re Génération Puissance nominale du rèchauffer 0075 - 0.75 kW 0083 - 0.83 kW 009 - 0.90 kW 0113 - 1.13 kW 012 - 1.2 kW 0125 - 1.25 kW 0135 - 1.35 kW 018 - 1.8 kW 0226 - 2.26 kW 025 - 2.5 kW 0269 - 2.69 kW 0301 - 3.01 kW 0313 - 3.13 kW 0333 - 3.33 kW 0347 - 3.47 kW 0359 - 3.59 kW 036 - 3.6 kW 0476 - 4.76 kW 048 - 4.8 kW 050 - 5.0 kW 0528 - 5.28 kW 0568 - 5.68 kW 0626 - 6.26 kW 0694 - 6.94 kW 0747 - 7.47 kW 076 - 7.6 kW 100 - 10.0 kW Emplacements Autorisés Les réchauffeurs d'air à convection électrique sont homologués CULUS pour les emplacements dangereux suivants: (sans thermostat intégré) Classe I, divisions 1 et 2, groupes A, B, C D Classe I, zones 1 et2, groupes IIA, IIB, IIC Code de température T2A 536 °F (280 °C), T3 392 °F (200 °C) (avec thermostat intégré) Classe I, divisions 1 et 2, groupes A, B, C etD Classe I, zones 1 et2, groupes IIA, IIB, IIC Code de température T2A 280 °C (536 °F), T3 392 °F (200 °C) Pour plus de détails sur les emplacements dangereux à risque d'explosion, consulter le Code canadien de l'électricité, partie 1, section 18 ou le Code national de l'électricité, articles 500 - 516. ProVector® et RuffneckTM sont des marques déposées. Copyright © 2023. Tous droits réservés. Part No. 6348.Rev.18.06 jan 2023 imprimé au Canada TABLE DES MATIÈRES A. Liste de contrôle de maintenance du réchauffer 19 A.1 Périodic................................................................................................................................................19 A.2 Annuelle .............................................................................................................................................19 B. Avis importants 20 C. Installation 20 C.1 Installation méchanique........................................................................................................ 20 C.2 Installation électrique..............................................................................................................23 D. Spécifications 24 E. Diagramme des pièces 25 F. Liste des pièces 26 G. Réparation et remplacement 27 G.1 En semble de tuyaux à ailettes avec élément.........................................................27 G.2 Panneaux de boîtier et ferrures de fixation..............................................................27 H. Données techniques du CX1 28 H.1 1-Phase ................................................................................................................................................28 H.2 3- Phase............................................................................................................................................ 30 A. LISTE DE CONTRÔLE DE MAINTENANCE DU RÉCHAUFFER AVERTISSEMENT. Couper l'alimentation électrique du réchauffeur avant d'ouvrir le boîtier ou d'effectuer la maintenance. Régler l'interrupteur à la position "OFF" (arrêt) ou l'étiqueter pour empêcher tout branchement accidentel. AVERTISSEMENT Pour les chauffe marqués IIC, assurez-vous de desserrer la vis de réglage avant de retirer le couvercle. Seul du personnel qualifié est autorisé à effectuer la maintenance de ce réchauffeur. Modèle de réchauffeur Numéro de serie Commentaires Date de maintenance Maintenance faite par A.1 Périodic (avant ou, au besoin, pendant le périod de chauffe) Nettoyer Les tuyaux à ailettes Le dessus et le desous de l'unité Enlever la poussière au jet d'air comprimé Ne pas vaporiser d'eau ni de solvants. Ne pas immerger dans l'eau ni dans les solvants. Vérifer Si tous les couvercles antidéflagrants sont dien fixés. A.2 Annuelle (avant la périod de chauffe) Maintenance mécanique Vérifier tous les boîtiers. L'intérieur des boîtres doit être propre, sec et exampt de corps étrangers. Les joints de boître sont assemblés métal contre métal. N'utiliser aucun joint ni matériau d'étanchéité dans les joints. Vérifier le serrage de toutes les attaches. Tous les boulons, vis et écrous doivent être bien serrés. Fair fonctionner le réchauffeur pendant au moins 5 minutes. S'assurer que de l'air chaud sort pas les diffuseurs supéreurs du réchauffeur. Maintenance électrique Vérifier tous les conducteurs et bornes de connexion. Serrer les connexions lâches. Remplacer les conducteurs dont l'isolation est endommagée. Vérifier tous les conduits antidéflagrants. Remplacer les raccords-union, bouchons et conduits endommagés. Tous les raccords filletés doivant être vissés d'au moins 5 tours. Liste de contrôle de maintenance du réchauffer Pour de l'assistance, composer le numéro sans frais 1-800-661-8529 (24 heures sur 24) Canada et É.-U. 19 B. AVIS IMPORTANTS 8. ATTENTION. Lire et respecter les directives suivantes afin d'éviter tout risque de blessure grave ATTENTION ou mortelle. Le garantie sera annulée si ces directives ne sont pas suivres. 9. 1. Lire et respecter toutes les directives du présent guide. 10. 2. N'utiliser le réchauffeur que dans les emplacements où la température d'inflammation est supérieure à la température de fonctionnement maximale du réchauffeur, telle qu'indiquée sur la plaque signalétique. 11. Pour de plus amples renseignements, consulter les codes électriques en vigueur. 3. Le réchauffeur ne doit être utilisé que dans les emplacements dangereux spécifiés sur la plaque signalétique. 4. Le réchauffeur ne doit être utilisé qu'à l'intérieur, et au sec. Ne pas immerger dans l'eau. Ne pas entreposer ni utiliser dans des emplacements exposés à la pluie ou à 12. la neige. 5. La température ambiante maximale de fonctionnement 13. est de 104 °F (40 °C). 6. Seul un électricien qualifié et expérimenté avec les 14. équipements destinés aux emplacements dangereux est autorisé à effectuer le raccordement et la maintenance 15. du réchauffeur. 7. L'installation et le câblage du réchauffeur doivent être 16. conformes à tous les codes en vigueur. Avant d'ouvrir un boîtier, couper l'alimentation électrique du réchauffeur. Régler l'interrupteur à la position "OFF" (arrêt) ou l'étiqueter pour empêcher tout branchement accidentel. Les surfaces externes chauffent et peuvent causer des brûlures en cas de contact prolongé. Ne faire fonctionner le réchauffeur que lorsqu'il est installé de façon permanente en position verticale. Pour plus de détails, consulter la section C.1 Installation méchanique, page 20. Garder le réchauffeur toujours propre. Lorsqu'on l'utilise dans un environnement propice à la saleté, on doit nettoyer régulièrement les tuyaux à ailettes et les diffuseurs du haut, en s'assurant que rien n'obstrue la prise d'air (ouverture inférieure). Suivre les procédures de maintenance recommandées. Consulter la section A. Liste de contrôle de maintenance du réchauffer, page 19. Ne pas faire fonctionner le réchauffeur dans des environnements corrosifs pour l'acier ou l'aluminium. N'utiliser que les pièces de rechange originales du fabricant. Les joints de conduit ne sont pas requis dans les conduits installés dans le réchauffeur à l'usine. Un joint d'étanchéité doit être en place à moins de 15,3 cm (6 po) des entrées de champ. Pour toute question ou préoccupation concernant cet appareil de chauffage, contacter le fabricant. Consulter la dernière page du présent manuel pour de plus amples détails. C. INSTALLATION Les directives d'installation donnent une idée générale de l'installation et du câblage du réchauffeur. Se conformer à tous les codes en vigueur. Résister aux chocs comme ceux subis dans les installations C.1 Installation méchanique 1. Positionnement 1.1 Ne jamais diriger la sortie d'air vers un thermostat. 1.2 Diriger la sortie d'air vers les zones de déperdition thermique, comme les portes ou les fenêtres. 1.3 Pour protéger un équipement contre le gel, installer le réchauffeur le plus près possible de cet équipement. Avis Importants / Installation 2. Installation 2.1 Ce réchauffeur doit être installé de niveau horizontal et contre une paroi verticale, en utilisant les ferrures de fixation fournies par le fabricant, afin qu'il n'y ait aucune obstruction limitant l'entrée ni la sortie d'air. 2.2 La surface de montage doit être suffisamment solide pour: 1,5 po (38,0 mm) Supporter le poids du réchauffeur, voir la Section D. 20 Spécifications, page 24. Figure 1 2.3 Viser les ferrures de fixation à la paroi verticale dans le trou de fixation supérieur, situé à 1,5 po (38 mm) sous la hauteur de la surface supérieure voulue (Figure 1, page 20). Voir Figure 3, page 5, Figure 4, et Figure 5, page 22 le dégagement requis pour l'installation. Espacer les ferrures de fixation afin qu'elles s'alignent sur les fentes du panneau arrière du réchauffeur. 2.4 Après avoir fixé les ferrures de fixation, incliner le réchauffeur et l'abaisser dans les pattes supérieures de la ferrure de fixation afin que les pattes s'insèrent dans les fentes de fixation du panneau arrière du réchauffeur (Figure 2, page 21). 2.5 Basculer, soigneusement, le bas du réchauffeur dans les ferrures de fixation afin qu'il puisse reposer sur la patte inférieure (Figure 2, page 21). 2.6 Insérer les vis de fixation dans la patte inférieure de la ferrure de fixation et dans le boîtier afin que le réchauffeur ne se déloge pas de la ferrure de fixation (Figure 2, page 21). 2.7 AVERTISEMENT: Utiliser uniquement des fixations dont la limite d'élasticité est supérieure ou égale à 58 ksi (400 MPa). Ferrure de fixation Détail de la patte supérieure Figure 2 Vis de fixation Détail de la patte inférieure Appareils de chauffage de groupe B, C, D avec boîtier Defender® Chauffe kW 'A' Dimension Sans extension Avec extension po (mm) po (mm) 0.75 2.69 & 3.6 (T2A) 3.01 3.59, 3.6 (T3) & 4.8 36.9 (938) 55.0 (1398) 39.0 (991) 57.1 (1451) 4.76, 5.28 7.6* 3.13, 3.47, 3.74, 5.0, 6.26, 6.94, 7.47 & 10.0 65.1 (1653) 77.4 (1965) 67.2 (1706) 79.4 (2018) *Sauf 7.6 kW, 208, 3Ø et 10 kW, 208V, et 277V, 3Ø unités **1Ø thermostats nécessitent une rallonge 'B' Dimension po (mm) 31.34 (796) 49.45 (1256) 59.49 (1511) 71.78 (1823) 'E' Dimension Sans extension Avec extension po (mm) po (mm) 5.6 (142) 7.7 (195) Figure 3 Dimensions Installation 21 Appareils de chauffage de groupe A, B, C, D avec boîtier x-Max® Chauffe kW 0.75 à 2.69 & 3.6 (T2A) 3.01 à 3.59, 3.6 (T3) & 4.8 4.76, 5.28 à 7.6* 3.13, 3.47, 3.74, 5.0, 6.26, 6.94, 7.47 & 10.0 1Ø Sans extension 'D' Dimension 1Ø* Avec extension po (mm) po (mm) 37.6 (954) 55.7 (1414) 65.7 (1669) 39.6 (1007) 57.8 (1467) 67.8 (1722) 3Ø Unités po (mm) 38.3 (973) 56.4 (1433) 66.5 (1688) 'B' Dimension po (mm) 31.34 (796) 49.45 (1256) 59.49 (1511) 78.0 (1981) 80.1 (2034) 78.7 (2000) 71.78 (1823) **1Ø thermostats nécessitent une rallonge Figure 4 Dimensions 'E' Dimension Sans extension Avec extension po (mm) po (mm) 6.2 (158) 8.3 (211) 3Ø Unités po (mm) 7.0 (177) Minimum 18 po (457 mm) Minimum 0,375 po (9,5 mm) 48,0 po (1219 mm) Requis pour faciliter l'installation et la maintenance Minimum 8,0 po (203 mm) Plancher Figure 5 Les distances de dégagement Minimum 0,375 po (9,5 mm) Mur 12 po (305 mm) Requis pour faciliter l'installation Installation 22 C.2 Installation électrique AVERTISSEMENT. Déconnectez l'alimentation électrique avant d'installer lechauffage. AVERTISSEMENT Bloquez l'interrupteur en position « OFF » (ouvert) ou marquez l'interrupteur pour éviter une mise en marche imprévue de l'alimentation. Pour les chauffages marqués « IIC », assurez-vous de desserrer les vis d'arrêt avant de retirer le couvercle. L'installation et le câblage de l'appareil de chauffage doivent être conformes à tous les codes applicables. 1. Généralités 1.1 Pour l'installation, n'utiliser que des conducteurs de cuivre et suivre les méthodes approuvées de câblage antidéflagrant. Pour dimensionner correctement les conducteurs appropriés, vérifier les valeurs nominales de tension, d'ampérage et de puissance indiquées à la section H. Données techniques du CX1, page 28 et sur la plaque signalétique du réchauffeur. Tous les conducteurs d'alimentation doivent pouvoir supporter une température de fonctionnement s'élevant jusqu'à 194°F (90°C). 1.2 La tension d'alimentation doit être à ±10 % de la tension spécifiée sur la plaque signalétique. Installer un dispositif de protection contre les surintensités de courant, adéquat pour la tension, l'ampérage et la fréquence indiqués sur la plaque signalétique. 2. Câblage sur place 2.1 L'appareil de chauffage est fourni avec un boîtier ayant une ouverture filetée de 3/4 po NPT ou 1 po NPT pour les conducteurs d'alimentation (voir Figure 4, page 22 et Figure 5, page 22 pour les détails concernant la connexion). Utiliser des connecteurs de fil pouvant supporter une température de 194°F (90°C) au minimum. REMARQUE: En cas d'utilisation de thermostats à distance différents de ceux livrés par le fabricant, s'assurer qu'ils maintiendront la température ambiante inférieure à la température ambiante admissible du thermostat (104°F/40°C) et qu'ils sont conformes à la classe d'atmosphère dangereuse du lieu d'installation. S'assurer que les caractéristiques de tension et d'ampérage des dispositifs de régulation utilisés correspondent à celles du réchauffeur. Sinon, un contacteur peut être requis. 3. Inspection Finale Avant de mettre sous tension: 3.1 S'assurer que toutes les connexions sont serrées et conformes au schéma de câblage (voir la Figure 4, page 22 et Figure 5, page 22 et aux codes en vigueur; 3.2 Confirment que la tension d'alimentation et de phase sont compatibles avec les spécifications de la plaque de données; 3.3 Retirer tout corps étranger de l'intérieur du réchauffeur; et 3.4 S'assurer que tous les raccords externes et les panneaux du boîtier sont bien fixés. Élément L1* L2 Élément Thermostat d'ambiance *Pour les unités à120V, L1 représente le fil neutre Figure 6 Schéma de câblage pour thermostats d'ambiance intégrés ou à distance (1Ø unités) Thermostat d'ambiance DPST Éléments L1 L2 L3 Câble de mise à la terre Figure 7 Schéma de câblage pour thermostats d'ambiance intégrés ou à distance (3Ø unités) Installation 23 D. SPÉCIFICATIONS Longueur du cabinet Poids net Poinds à la l'expédition po mm lbs kg lbs kg 0.75 - 2.69 & 3.6 (T2A) 31.3 796 55.3 25.1 65 30 Puissance nominale kW 3.01, 3.33, 3.59, 3.6 (T3), 4.8 4.76, 5.28, 5.68, 7.6 49.4 59.5 1256 1511 80.7 92.8 36.6 42.1 95 105 44 47.6 3.13, 3.47, 3.74, 5.0, 6.26, 6.94, 7.47, 10.0 71.8 1823 107.6 48.9 122 55.5 Spécificationspourmodèles 1. Emplacements dangereux 2. Boîtiers 3. Ferrures de fixation Sans t-stat intégré* Classe I, Div. 1 et 2, Groupes B, C, et D; Zones 1 et 2 Groupes IIA, IIB + H2 (Defender® boîtier) Classe I, Div. 1 et 2, Groupes A, B, C, et D, Groupes IIA, IIB, IIC (x-Max®) Avec t-stat intégré* Classe I, Div. 1 & 2, Groupes C, & D, Zones 1 &2, Groupes IIA, IIB (Defender® boîtier) ou, Classe I, Div. 1 & 2, Groupes A, B, C, D, Zones 1 & 2, Groupes IIA, IIB. IIC ( x-Max®) Defender® boîtier est en fonte d'aluminium avec vis sur le couvercle, Groupes IIB. x-Max® logement est en aluminium extrudé avec deux couvercles vissés. Le x-Max® offre le logement IP55 protection contre la pénétration d'humidité, Groupes IIC. Pour une utilisation en intérieur sec seulement. Ne pas plonger dans l'eau. Ne pas entreposer ou utiliser dans des zones exposées à la pluie ou la neige. Deux supports en acier galvanisé de calibre 14 (0,075 po/1,90 mm). 4. Éléments de chauffage Éléments à blindage en Incoloy®. 5. Matériau du boîtier 6. Code de température 7. Limites de température En acier de calibre 14. Le panneau arrière est galvanisé. Les panneaux avant et latéraux sont recouverts d'un revêtement en poudre d'époxyde cuite gris verdâtre avec prétraitement en cinq étapes, dont au phosphate de fer. T2A 536°F (280°C), T3 392°F (200°C) Fonctionnement: -49°F à 104°F (-45°C à 40°C) Entreposage: -49°F à 176°F (-45°C à 80°C) *Les cotes des emplacements dangereux sont tributaires de la boîte de jonction utilisé. S'il vous plaît consulter un représentant du service à la clientèle ou la plaque de l'unité de données pour les cotes emplacement réel. Spécifications 24 E. DIAGRAMME DES PIÈCES 8 2 PLCS 4 2 PLCS 9 11 2 PLCS 10 5 1 6 Vis d'assemblage 16 2 3 2 PLCS 8 C2 C1 Voir options de t'stat 7 IIB Option avec t'stat intégré 19 14 IIB + H2 Option sans t'stat intégré 9 IIC Option avec T3 code t'stat intégré 9 IIC Option sans T3 code t'stat intégré 9 9 13 1-Phase Wiring Vue détailée du conduit 12 19 Filage avec IIB intégré Câble de mise à la terre Filage sans IIB+H2 intégré 19 21 20 Filage avec IIC intégré Filage sans IIC intégré Brancher sur les «commun» et «norm. ouvert» du t'stat intégré 3-Phase Wiring Vue détailée du conduit Filage sans IIB+H2 intégré Filage sans IIC intégré Filage avec IIC intégré Diagramme des pièces 15 3 PLCS 16 Câble de mise à la 18 terre 3 PLCS 15 Câble de mise à la terre 25 F. LISTE DES PIÈCES Merci de préparervos numéros de modèle et de série avante d'appeler. Longueur du cabinet Article Description 1 Panneau avant 2 Panneau arrière Panneau droit - 1Ø unités 3 Panneau droit - 3Ø unités 4 Panneau gauche Ferrure, tuyau à ailette - 1Ø unités 5 Ferrure, tuyau à ailette - 3Ø unités 6 Ferrures de fixation au mur 7 Tuyaux à ailettes avec élément Écrou 3/4 po aluminium- 1Ø unités 8 Écrou 1 po NPT- 3Ø unités Raccord-union 3/4 po NPT mâle/femelle - 1Ø unités 9 Raccord-union 1 po NPT femelle - 3Ø unités Raccord-union 1 po NPT mâle/femelle - 3Ø unités 10 Conduit d'élément 11 Bouchon antidéflagrant 3/4 po 12 Ens. boîtier, Groupe B, (IIB + H2) 13 Boîtier du convecteur 14 Thermostat XCT intégré 15 Connecteur fil 150 °C (302 °F) 16 Vis à tôle, 10-24 x 1/2 po 17 Connect. fourche 12-10GA #10 18 Connecteur fil 300 °C (+) 19 Rallonge de Tube - 1Ø unités 20 Ens. thermostat intégré, XT - 1Ø unités 21 Ens. thermostat intégré, XT - 3Ø unités 22 Réduire douille - 3Ø unités 23 Tube Fileté - 3Ø unités 24 Réduire 3/4 x 1 po mâle/femelle - 3Ø unités 31,5 po (796 mm) 49,4 po (1256 mm) No. de Qté No. de Qté pièce pièce 6488 1 6493 1 6487 1 6494 1 6491 1 6491 1 12304 1 12304 1 6492 1 6492 1 6485 1 6485 1 12303 1 12303 1 6602 1 6602 1 * 2 * 2 6449 4 6449 4 12676 4 12676 4 59,5 po (1511 mm) No. de Qté pièce 6490 1 6489 1 6491 1 12304 1 6492 1 6485 1 12303 1 6602 1 * 2 6449 4 12676 4 6506 4 6506 4 6506 4 12677 2 12677 2 12677 2 12787 2 12787 6497 1 6497 1443 2 1443 6604 1 6604 6211 1 6211 6603 1 6603 4972 20 4972 2088 2 2088 6529 + 6529 7202 2 7202 11773 1 11773 13728 1 13728 12679 2 12679 12678 2 12678 12867 2 12867 2 12787 2 1 6497 1 2 1443 2 1 6604 1 1 6211 1 1 6603 1 ** 21 4972 22 2 2088 2 + 6529 + 2 7202 2 1 11773 1 1 12876 1 2 12679 2 2 12678 2 2 12867 2 71,78 po (1823 mm) No. de Qté pièce 12305 1 12306 1 6491 1 12304 1 6492 1 6485 1 12303 1 6602 1 * 2 6449 4 12676 4 6506 4 12677 2 12787 2 6497 1 1443 2 6604 1 6211 1 6603 1 4972 24 2088 2 6529 + 7202 2 11773 1 12876 1 12679 2 12678 2 12867 2 Remarques * Contactez l'usine pour le kit de remplacement du tuyau à ailettes et d'élément. ** Fourni par le client. Quantité variable: 1 (pour l'option thermostat intégré) ou 2 (pour l'option thermostat à distance). *** 7,6 kW; 208V; 3Ø et 10k W; 208V; 240V et 277V, 3Ø seulment. + La quantité nécessaire est variable : 1 pour 1Ø, 2 pour 3Ø Liste des pièces 26 G. RÉPARATION ET REMPLACEMENT AVERTISSEMENT. Couper l'alimentation électrique avant d'installer le réchauffeur. Régler l'interrupteur AVERTISSEMENT à la position "OFF" (arrêt) ou l'étiqueter pour empêcher tout branchement accidentel. Les surfaces du réchauffeur peuvent être chaudes. G.1 En semble de tuyaux à ailettes avec élément L'ensemble complet de tuyaux à ailettes avec élément est disponible auprès du fabricant. Consulter la section E. Diagramme des pièces, page 25 pour les numéros de pièces. 1. Retirer le panneau avant du boîtier (article Nº 1). 2. Découplez les deux raccords (article Nº 9) qui relient l'enveloppe du radiateur et le tuyau à ailettes (article Nº 7). 3. Retirez la prise NPT de 3/4 po (article Nº 11) du conduit (article Nº 10) et tirez le connecteur de câble puis débranchez les fils. 4. Retirer le bouchon de 3/4 po NPT (article Nº 11) du conduit d'élément (article Nº 10), puis tirer pour sortir le connecteur de fil et débrancher les fils. 5. Défaire les deux autres raccords-union et retirer le conduit d'élément. 6. Retirer les raccords-union et l'écrou de blocage (article Nº 8) des extrémités de chaque tuyau à ailettes devant être remplacé et les garder pour les réutiliser avec les nouveaux tuyaux à ailettes du fabricant. 7. Retirer les vis des pattes inférieures des ferrures de fixation au mur (article Nº 6), retirer le réchauffeur des ferrures de fixation au mur et desserrer les vis de la ferrure du tuyau à ailettes (article Nº 5). 8. Retirer les tuyaux à ailettes (avec élément) endommagés et installer de nouveaux tuyaux à ailettes. 9. Remonter le réchauffeur en suivant la procédure précédente, mais dans l'ordre inverse. IMPORTANTE: Tous les raccords filetés doivent être serrés avec une clé en vissant d'au moins 5 tours. G.2 Panneauxdeboîtieretferruresdefixation Les pièces de rechange des panneaux de boîtier et des ferrures de fixation de rechange sont disponibles auprès du fabricant. REMARQUE: Pour des raisons pratiques et de sécurité, toutes les réparations et tous les travaux de maintenance doivent être effectués en utilisant les pièces et matériaux originaux du fabricant. Réparation et remplacement 27 H. DONNÉES TECHNIQUES DU CX1 Tension nominale Calibre de câble d'aim. *** Courant nominal Fusible de circuit Longueur du boîtier Code de temperature Modèle kW (Btu/ hr) CX1-120160-012-T3 CX1-120160-018-T3 CX1-208160-012-T3 CX1-208160-018-T3 CX1-208160-036-T3** CX1-208160-048-T2A CX1-208160-050-T3 CX1-208160-076-T2A CX1-240160-012-T3 CX1-240160-018-T3 CX1-240160-036-T3** CX1-240160-048-T2A CX1-240160-050-T3 CX1-240160-076-T2A CX1-277160-012-T3 CX1-277160-018-T3 CX1-277160-036-T3** CX1-277160-048-T2A CX1-277160-050-T3 CX1-277160-076-T2A CX1-380160-0075-T3 CX1-380160-0113-T3 CX1-380160-012-T3 CX1-380160-018-T3 CX1-380160-0226-T2A CX1-380160-0301-T3 CX1-380160-0313-T3 CX1-380160-036-T3** CX1-380160-0476-T2A CX1-380160-048-T2A CX1-380160-050-T3 CX1-380160-0626-T2A CX1-380160-076-T2A CX1-380160-100-T2A CX1-400160-0083-T3 CX1-400160-012-T3 1.2 (4095) 1.8 (6142) 1.2 (4095) 1.8 (6142) 3.6 (12284) 4.8 (16378) 5.0 (17060) 7.6 (25932) 1.2 (4095) 1.8 (6142) 3.6 (12284) 4.8 (16378) 5.0 (17060) 7.6 (25932) 1.2 (4095) 1.8 (6142) 3.6 (12284) 4.8 (16378) 5.0 (17060) 7.6 (25932) 0.75 (2560) 1.13 (3856) 1.2 (4095) 1.8 (6142) 2.26 (7711) 3.01 (10271) 3.13 (10680) 3.6 (12284) 4.76 (16241) 4.8 (16378) 5.0 (17060) 62.6 (21360) 7.6 (25932) 10.0 (34121) 0.83 (2832) 1.2 (4095) V 120 120 208 208 208 208 208 208 240 240 240 240 240 240 277 277 277 277 277 277 380 380 380 380 380 380 380 380 380 380 380 380 380 380 400 400 IIB + H2 Groupe de gaz IIB IIC Sans t'stat Avec Sans t'stat t'stat Avec t'stat N/A N/A N/A N/A N/A N/A N/A N/A + N/A N/A N/A N/A AWG 12 12 12 12 12 8 8 8 12 12 12 10 8 8 12 12 12 12 8 8 12 12 12 12 12 12 12 12 10 10 10 8 8 8 12 12 A 10.0 15.0 5.8 8.7 17.3 23.1 24.0 36.5 5.0 7.5 15.0 20.0 20.8 31.7 4.3 6.5 13.0 17.3 18.1 27.4 2.0 3.0 3.2 4.7 5.9 7.9 8.2 9.5 12.5 12.6 13.2 16.5 20.0 26.3 2.1 3.0 A po mm 15 31.3 796 T3 (200) 20 31.3 796 T3 (200) 15 31.3 796 T3 (200) 15 31.3 796 T3 (200) 25 49.5 1256 T3 (200) 30 49.5 1256 T2A (280) 30 71.8 1823 T3 (200) 50 59.5 1511 T2A (280) 15 31.3 796 T3 (200) 15 31.3 796 T3 (200) 20 49.5 1256 T3 (200) 25 49.5 1256 T2A (280) 30 71.8 1823 T3 (200) 40 59.5 1511 T2A (280) 15 31.3 796 T3 (200) 15 31.3 796 T3 (200) 20 49.5 1256 T3 (200) 25 49.5 1256 T2A (280) 25 71.8 1823 T3 (200) 35 59.5 1511 T2A (280) 15 31.3 796 T3 (200) 15 31.3 796 T3 (200) 15 31.3 796 T3 (200) 15 31.3 796 T3 (200) 15 31.3 796 T2A (280) 15 49.5 1256 T3 (200) 15 71.8 1823 T3 (200) 15 49.5 1256 T3 (200) 20 59.5 1511 T2A (280) 20 49.5 1256 T2A (280) 20 71.8 1823 T3 (200) 25 71.8 1823 T2A (280) 25 59.5 1511 T2A (280) 35 71.8 1823 T2A (280) 15 31.3 796 T3 (200) 15 31.3 796 T3 (200) Remarques * Ou disjoncteur équivalent conforme aux normes locales d'inspection électrique. 1. Le réchauffeur fonctionne normalement si, à la tension nominale, l'ampérage est à 10% près de la valeur de ce tableau. ** Pour 3,6 kW chauffage nominal longueur armoire T3 est de 49,5 po 2. Le fonctionnement à une tension inférieure à la tension nominale réduira la (1256 mm). 3.6 chauffe kW longueur armoire T2A est de 31,3 po (796 mm). puissance consommée et l'ampérage. ***Assurez-vous de fournir adhère à la taille de fil locaux et nationaux applicables codes électriques. Puissance réelle (kW) = [(Tension d'alimentation)2 ÷ (Tension nominale)2] x Puissance nominale (kW). 3. Ajouter le suffixe «T» pour option thermostat intégré. Thermostat n'est pas disponible sur les modèles IIB + H2. Données techniques du CX1 28 Tension nominale Calibre de câble d'aim. *** Courant nominal Fusible de circuit Longueur du boîtier Code de temperature Modèle kW (Btu/ hr) CX1-400160-0125-T3 CX1-400160-018-T3 CX1-400160-025-T2A CX1-400160-0333-T3 CX1-400160-0347-T3 CX1-400160-036-T3** CX1-400160-048-T2A CX1-400160-050-T3 CX1-400160-0528-T2A CX1-400160-0694-T3 CX1-400160-076-T2A CX1-400160-100-T2A CX1-415160-009-T3 CX1-415160-012-T3 CX1-415160-0135-T3 CX1-415160-018-T3 CX1-415160-0269-T2A CX1-415160-0359-T3 CX1-415160-036-T3** CX1-415160-0374-T3 CX1-415160-048-T2A CX1-415160-050-T3 CX1-415160-0568-T2A CX1-415160-0747-T2A CX1-415160-076-T2A CX1-415160-100-T2A CX1-480160-012-T3 CX1-480160-018-T3 CX1-480160-036-T3** CX1-480160-048-T2A CX1-480160-050-T3 CX1-480160-076-T2A CX1-480160-100-T2A CX1-600160-012-T3 CX1-600160-018-T3 CX1-600160-036-T3** CX1-600160-048-T2A CX1-600160-050-T3 CX1-600160-076-T2A CX1-600160-100-T2A 1.25 (4565) 1.8 (6142) 2.5 (8530) 3.33 (11362) 3.47 (11840) 3.6 (12284) 4.8 (16378) 5.0 (17060) 5.28 (18016) 6.94 (23680) 7.6 (25932) 10.0 (34121) 0.9 (3071) 1.2 (4095) 1.35 (4606) 1.8 (6142) 2.69 (9179) 3.59 (12250) 3.6 (12284) 3.74 (12761) 4.8 (16378) 5.0 (17060) 5.68 (19381) 7.47 (25488) 7.6 (25932) 10.0 (34121) 1.2 (4095) 1.8 (6142) 3.6 (12284) 4.8 (16378) 5.0 (17060) 7.6 (25932) 10.0 (34121) 1.2 (4095) 1.8 (6142) 3.6 (12284) 4.8 (16378) 5.0 (17060) 7.6 (25932) 10.0 (34121) V 400 400 400 400 400 400 400 400 400 400 400 400 415 415 415 415 415 415 415 415 415 415 415 415 415 415 480 480 480 480 480 480 480 600 600 600 600 600 600 600 IIB + H2 Groupe de gaz IIB IIC Sans t'stat Avec Sans t'stat t'stat Avec t'stat + N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A AWG 12 12 12 12 12 12 10 10 10 8 8 8 12 12 12 12 12 12 12 12 10 10 10 8 8 8 12 12 12 12 12 10 8 12 12 12 12 12 12 10 A 3.1 4.5 6.3 8.3 8.7 9.0 12.0 12.5 13.2 17.4 19.0 25.0 2.2 2.9 3.3 4.3 6.5 8.7 8.7 9.0 11.6 12.0 13.7 18.0 18.3 24.1 2.5 3.8 7.5 10.0 10.4 15.8 20.8 2.0 3.0 6.0 8.0 8.3 12.7 16.7 A po mm 15 31.3 796 T3 (200) 15 31.3 796 T3 (200) 15 31.3 796 T2A (280) 15 49.5 1256 T3 (200) 15 71.8 1823 T3 (200) 15 49.5 1256 T3 (200) 15 49.5 1256 T2A (280) 20 71.8 1823 T3 (200) 20 59.5 1511 T2A (280) 25 71.8 1823 T3 (200) 30 59.5 1511 T2A (280) 35 71.8 1823 T2A (280) 15 31.3 796 T3 (200) 15 31.3 796 T3 (200) 15 31.3 796 T3 (200) 15 31.3 796 T3 (200) 15 31.3 796 T2A (280) 15 49.5 1256 T3 (200) 15 49.5 1256 T3 (200) 15 71.8 1823 T3 (200) 15 49.5 1256 T2A (280) 15 71.8 1823 T3 (200) 20 59.5 1511 T2A (280) 25 71.8 1823 T2A (280) 25 59.5 1511 T2A (280) 35 71.8 1823 T2A (280) 15 31.3 796 T3 (200) 15 31.3 796 T3 (200) 15 49.5 1256 T3 (200) 15 49.5 1256 T2A (280) 15 71.8 1823 T3 (200) 20 59.5 1511 T2A (280) 30 71.8 1823 T2A (280) 15 31.3 796 T3 (200) 15 31.3 796 T3 (200) 15 49.5 1256 T3 (200) 15 49.5 1256 T2A (280) 15 71.8 1823 T3 (200) 20 59.5 1511 T2A (280) 25 71.8 1823 T2A (280) Données techniques du CX1 4. Ajouter le suffixe «H» pour option haute température de stockage 8. Monté à distance, Defender, thermostats d'ambiance anti-explosion ne ambiante. Option haute température de stockage n'est pas disponible avec sont pas adaptés pour le Groupe B & IIC applications. l'option thermostat. Non disponible sur les modèles IIB. 5. Pour le modèle IIB avec Defender® thermostat intégré - Classe I, Div. 1 & 2, 9. Contacteurs à distance sont nécessaires sur tous les chauffe-600V et appareils de chauffage avec un appel de courant supérieur à 22 ampères Groupes C et D; Zones 1 & 2, Groupes IIA et IIB. (fournie et installée par d'autres), lors de l'utilisation XT-311 6. Pour IIC modèle XT avec thermostat intégré - Classe I, Div. 1 & 2, Groupes A, thermostat à distance. B, C et D; Zones 1 & 2, Groupes IIA, IIB et IIC. 10. Codification de température: T2A - 536°F (280°C), T3 - 392°F 7. Regroupement des unités de la SII sont livrés avec x-Max® logement. (200°C) . 29 Tension nominale Calibre de câble d'aim. *** Courant nominal Fusible de circuit Longueur du boîtier Code de temperature H.1 1-Phase Modèle kW (Btu/hr) CX1-208360-012-T3 CX1-208360-018-T3 CX1-208360-036-T3** CX1-208360-048-T2A CX1-208360-050-T3 CX1-208360-076-T2A CX1-208360-100-T2A CX1-240360-012-T3 CX1-240360-018-T3 CX1-240360-036-T3** CX1-240360-048-T2A CX1-240360-050-T3 CX1-240360-076-T2A CX1-240360-100-T2A CX1-277360-012-T3 CX1-277360-018-T3 CX1-277360-036-T3** CX1-277360-048-T2A CX1-277360-050-T3 CX1-277360-076-T2A CX1-277360-100-T2A CX1-380360-0113-T3 CX1-380360-0226-T2A CX1-380360-0301-T3 CX1-380360-0313-T3 CX1-380360-0476-T2A CX1-380360-050-T3 CX1-380360-0626-T2A CX1-380360-100-T2A CX1-400360-0125-T3 1.2 (4095) 1.8 (6142) 3.6 (12284) 4.8 (16378) 5.0 (17060) 7.6 (25932) 10.0 (34121) 1.2 (4095) 1.8 (6142) 3.6 (12284) 4.8 (16378) 5.0 (17060) 7.6 (25932) 10.0 (34121) 1.2 (4095) 1.8 (6142) 3.6 (12284) 4.8 (16378) 5.0 (17060) 7.6 (25932) 10.0 (34121) 1.13 (3856) 2.26 (7711) 3.01 (10271) 3.13 (10680) 4.76 (16241) 5.0 (17060) 6.26 (21360) 10.0 (34121) 1.25 (4565) V 208 208 208 208 208 208 208 240 240 240 240 240 240 240 277 277 277 277 277 277 277 380 380 380 380 380 380 380 380 400 Groupe de gaz IIB + H2 IIB IIC Sans t'stat N/A N/A N/A N/A Avec Sans Avec t'stat t'stat t'stat N/A AWG 12 12 12 10 10 8 8 12 12 12 12 12 10 8 12 12 12 12 12 10 8 12 12 12 12 12 12 12 10 12 A 3.3 5.0 10.0 13.3 13.9 21.1 27.8 2.9 4.3 8.7 11.5 12.0 18.3 24.1 2.5 3.8 7.5 10.0 10.4 15.8 20.8 1.7 3.4 4.6 4.8 7.2 7.6 9.5 15.2 1.8 A po (mm) mm 15 31.3 (796) T3 (200) 15 31.3 (796) T3 (200) T3 (200) 15 49.5 (1256) 10 20 49.5 (1256) T2A (280) 20 71.8 (1823) T3 (200) 30 59.5 (1511) T2A (280) 35 71.8 (1823) T2A (280) 15 31.3 (796) T3 (200) 15 31.3 (796) T3 (200) T3 (200) 15 49.5 (1256) 12 20 49.5 (1256) T2A (280) 15 71.8 (1823) T3 (200) 25 59.5 (1511) T2A (280) 35 71.8 (1823) T2A (280) 15 31.3 (796) T3 (200) 15 31.3 (796) T3 (200) T3 (200) 15 49.5 (1256) 10 15 49.5 (1256) T2A (280) 15 71.8 (1823) T3 (200) 20 59.5 (1511) T2A (280) 30 71.8 (1823) T2A (280) 15 31.3 (796) T3 (200) 15 31.3 (796) T2A (280) 15 49.5 (1256) T3 (200) 15 71.8 (1823) T3 (200) 15 59.5 (1511) T2A (280) 15 71.8 (1823) T3 (200) 15 71.8 (1823) T2A (280) 20 71.8 (1823) T2A (280) 15 31.3 (796) T3 (200) Données techniques du CX1 Remarques * Ou disjoncteur équivalent conforme aux normes locales d'inspection électrique. 1. Le réchauffeur fonctionne normalement si, à la tension nominale, l'ampérage est à 10% près de la valeur de ce tableau. ** Pour 3,6 kW chauffage nominal longueur armoire T3 est de 49,5 po 2. Le fonctionnement à une tension inférieure à la tension nominale réduira la (1256 mm). 3. chauffe kW longueur armoire T2A est de 31,3 po (796 mm). puissance consommée et l'ampérage. ***Assurez-vous de fournir adhère à la taille de fil locaux et nationaux applicables codes électriques. · Disponible en IIB seulement Puissance réelle (kW) = [(Tension d'alimentation)2 ÷ (Tension nominale)2] x Puissance nominale (kW). 3. Ajouter le suffixe «T» pour option thermostat intégré. Thermostat n'est pas disponible sur les modèles IIB + H2. 30 Tension nominale Calibre de câble d'aim. *** Courant nominal Fusible de circuit Longueur du boîtier Code de temperature H.2 3-Phase Groupe de gaz Modèle kW (Btu/hr) IIB + H2 IIB IIC Sans Avec Sans Avec V t'stat t'stat t'stat t'stat AWG A CX1-400360-025-T2A CX1-400360-0333-T3 CX1-400360-0347-T3 CX1-400360-050-T3 CX1-400360-0528-T2A CX1-400360-0694-T2A CX1-400360-100-T2A CX1-415360-0135-T3 CX1-415360-0269-T2A CX1-415360-0359-T3 CX1-415360-0374-T3 CX1-415360-050-T3 2.5 (8530) 3.33 (11362) 3.47 (11840) 5.0 (17060) 5.28 (18016) 6.94 (23680) 10.0 (34121) 1.35 (4606) 2.69 (9179) 3.59 (12250) 3.74 (12761) 5.0 (17060) 400 400 400 400 400 400 400 415 415 415 415 415 12 3.6 12 4.8 12 5.0 12 7.2 12 7.6 12 10.0 10 14.4 12 1.9 12 3.7 12 5.0 12 5.2 12 7.0 CX1-415360-0568-T2A 5.68 (19381) 415 12 7.9 CX1-415360-0747-T2A 7.47 (25488) 415 CX1-415360-100-T2A 10.0 (34121) 415 12 10.4 N/A 10 13.9 CX1-480360-018-T3 1.8 (6142) 480 12 2.2 CX1-480360-036-T3** 3.6 (12284) 480 12 4.3 CX1-480360-048-T2A 4.8 (16378) 480 CX1-480360-050-T3 5.0 (17060) 480 CX1-480360-076-T2A 7.6 (25932) 480 CX1-480360-100-T2A 10.0 (34121) 480 12 5.8 12 6.0 12 9.1 12 12.0 CX1-600360-036-T3** 3.6 (12284) 600 CX1-600360-048-T2A 4.8 (16378) 600 CX1-600360-050-T3 5.0 (17060) 600 CX1-600360-076-T2A 7.6 (25932) 600 CX1-600360-100-T2A 10.0 (34121) 600 12 3.5 12 4.6 12 4.8 12 7.3 12 9.6 A po (mm) mm 15 31.3 (796) T2A (280) 15 49.5 (1256) T3 (200) 15 71.8 (1823) T3 (200) 15 71.8 (1823) T3 (200) 15 59.5 (1511) T2A (280) 15 71.8 (1823) T3 (200) 20 71.8 (1823) T2A (280) 15 31.3 (796) T3 (200) 15 31.3 (796) T2A (280) 15 49.5 (1256) T3 (200) 15 71.8 (1823) T3 (200) 15 71.8 (1823) T3 (200) 15 59.5 (1511) T2A (280) 15 71.8 (1823) T2A (280) 20 71.8 (1823) T2A (280) 15 31.3 (796) T3 (200) T3 (200) 15 49.5 (1256) T2A (280) 15 49.5 (1256) T2A (280) 15 71.8 (1823) T3 (200) 15 59.5 (1511) T2A (280) 15 71.8 (1823) T2A (280) T3 (200) 15 49.5 (1256) T2A (280) 15 49.5 (1256) T2A (280) 15 71.8 (1823) T3 (200) 15 59.5 (1511) T2A (280) 15 71.8 (1823) T2A (280) Données techniques du CX1 4. Ajouter le suffixe «H» pour option haute température de stockage ambiante. 8. Monté à distance, Defender®, thermostats d'ambiance anti-explosion ne Option haute température de stockage n'est pas disponible avec l'option sont pas adaptés pour le Groupe B & IIC applications. thermostat. Non disponible sur les modèles IIB. 5. Pour le modèle IIB avec Defender® thermostat intégré - Classe I, Div. 1 & 2, 9. Contacteurs à distance sont nécessaires sur tous les chauffe-600V et appareils de chauffage avec un appel de courant supérieur à 22 ampères Groupes C et D; Zones 1 & 2, Groupes IIA et IIB. (fournie et installée par d'autres), lors de l'utilisation XT-311 6. Pour IIC modèle XT avec thermostat intégré - Classe I, Div. 1 & 2, Groupes A, B, thermostat à distance. C et D; Zones 1 & 2, Groupes IIA, IIB et IIC. 10. Codification de température: T2A - 536°F (280°C), T3 - 392°F (200°C) . 7. Regroupement des unités de la SII sont livrés avec x-Max® logement. 31 VEUILLEZ VOUS CONFORMER AUX INSTRUCTIONS CONTENUES DANS CE MANUEL. Tout manquement à ces dernières pourrait s'avérer dangereux et invalider certaines dispositions de votre garantie. Pour obtenir une aide supplémentaire, veuillez appeler: 1-800-661-8529 (U.S.A. and Canada) Merci de préparervos numéros de modèle et de série avante d'appeler. Aucune garantie ne s'applique à la finition de peinture, excepté dans le garantit à l'acheteur que les produits ayant des défauts matériels ou de fabrication seront réparés ou remplacés sans frais pour une cas de défauts de fabrication apparents dans les 30 jours à compter de la date d'installation. période de 18 mois à compter de la date d'expédition ou 12 mois à partir de la date de début de fonctionnement, selon la date qui arrive à expiration la première. Toute réclamation dans le cadre de la garantie doit être adressée à l'agence commerciale dans laquelle le produit a été acheté afin d'obtenir une réparation ou un remplacement selon les termes de cette garantie. Non obstant toute loi fédérale ou provinciale au contraire, la Société ne pourra être tenue pour responsable des frais encourus pour l'installation, le retrait du service, le transport ou les dommages de quelque nature que ce soit, y compris les dommages résultant d'un manque d'utilisation, d'interruptions d'activité ou de dommages directs ou indirects. La Sociéte ne peut anticiper ou contrôler les conditions d'utilisation du produit et, par conséquent, décline toute responsabilité quant à l'application et l'adaptation en toute sécurité de ses produits lors de leur utilisation seuls ou en combinaison avec d'autres produits. Il est de la seule responsabilité de l'utilisateur d'effectuer des tests pour vérifier l'application et l'adaptation en toute sécurité des produits. Cette garatie sera nulle si, à l'appréciation de la Socitété, le dommage, la panne ou le défaut a été causé par: Le Société n'assume ni m'autorise auncune personne à assumer en son nom toute autre obligation ou responsabilité en rapport avec le/les produit(s). L'Acheteur accepte que la Société ne fournisse aucune garantie, expresse, implicite ou légale (y comprise toute garantie de qualité marchande ou de convenance à des fins particulières), écrite ou orale, du produit ou de la main-d'oeuvre indirecte, à l'exception des dispositions exprimées ou contenues dans le présent accord. RESPONSABILITÉ: Les données techniques contenues dans le catalogue ou sur le site Web song sujettes à modification sans préavis. La Société se réserve le droit d'apporter des modifications par rapport aux dimensions ou à la conception si nécessaire. L'Acheteur reconnaît que la Société ne sera pas dans l'obligation de modifier ces articles manufacturés avant la formulation des modifications de conception ou des améliorations apportées aux produit par la Société La Société ne sera pas tenue de dédomanger ou d'indemniser l'Acheteur, l'utilisateur final ou toute autre partie pour les actions, les réclamations les responsabilités, les préjudices les sinistres, la perte d'usage, le perte d'activité, les dommages, les dommages indirects ou consécutifs, les demands, les sanctions, les amendes, les dépanses · Des vibrations, des radiations, de l'érosion, de la corrosion, une contamination du processus, des conditions opératiores anormales, le températion et la pression, une poussée ou une pulsation anormale, l'encrassement, une usure normale, un manque d'entretien, des services appliqués de manière inappropriée tels que le voltage, l'air, le gaz l'eau et autres, ou toute autoriées par les conditions de régime; ou (y compris les dépenses légales), les pertes, les obligations et les conséquences d'une action de quelque nature que ce soit découlant entièrement ou en partie de la négligence ou de l'omission de l'utilisateur ou de la mauvise utilisation, de la mauvaise application, de l'utilisation dangereuse, de mauvaise installation, du manque d'entretien, du mauvaise entretien ou de la mauvaise opération des produits fournis par la Société. · Tout acte omission de la part de l'Acheteur ses agents, employés ou entrepreneur indépendant, comprenant pour une plus grande précision, mais pas au point de limiter la généralité de ce qui précède, une mauvaise utilisation physique, chimique ou mécanique, un accident, une mauvaise installation du produit, de mauvaises conditions de stockage ou de manipulation du produit, une application inappropriée ou en défaut d'alignment des pièces. Visitez www.thermon.com pour contacter un représentant Thermon près de chez vous. HEAD OFFICE: 7171 SOUTHWEST PKWY | BUILDING 300 SUITE 200 | AUSTIN, TX | 78735 | UNITED STATES RUFFNECK: 5918 ROPER ROAD | EDMONTON, AB | T6B-3E1 | CANADA, Ruffneck™ Adobe PDF Library 17.0