User Guide for NXP models including: MRF300AN Essentials Kit, MRF300AN, Essentials Kit

TWR-KL82Z72M Tower System Module Quick Start Guide

TWR-module, TWR-KL82Z72M Tower System Module

Freescale Semiconductor

TWR-KL82Z72M Tower System Module Quick Start Guide

2021-04-27 — Initial power on: 1. Mount baseplate onto a heatsink capable of dissipating more than 100 W. 2. Terminate RF output with a 50 ohm load capable of ...

27 apr 2021 — Initial power on: 1. Mount baseplate onto a heatsink capable of dissipating more than 100 W. 2. Terminate RF output with a 50 ohm load capable of ...


File Info : application/pdf, 4 Pages, 401.82KB

PDF preview unavailable. Download the PDF instead.

MRF300ANQuickReference 02-2021 v2
QUICK START GUIDE
MRF300AN KIT
MRF300AN ESSENTIALS KIT
Accelerate your RF amplifier design with the MRF300AN RF Essentials Component Kit.

GET TO KNOW THE MRF300AN KIT
Drain Voltage

Ground

R8 Potentiometer JP1
RFin

RFout

Alternatively, the jumper JP1 can be removed to supply an external gate voltage on the J1 connector
Figure 1: MRF300AN Board Connections

QUICK START GUIDE MRF300AN KIT
HOW TO GET STARTED
If the fixture is a new build: 1. Set gate bias to minimum by turning pot fully clockwise (12 turns). 2. Remove JP1 and check drain DC power terminal using an ohmmeter: DC power
terminal should read a high impedance. 3. Replace JP1.
Initial power on: 1. Mount baseplate onto a heatsink capable of dissipating more than 100 W. 2. Terminate RF output with a 50 ohm load capable of dissipating more than 330 W. 3. Connect RF input to a 50 ohm source with RF off. 4. Ensure the drain DC is set to 0 V. 5. Connect ground, drain DC. 6. Raise drain DC slowly to 50 Vdc. Current should be 0 A. 7. Adjust gate bias to desired target current, typically 50-500 mA. 8. Slowly increment RF input power source not exceeding 1 W. Monitor drain DC
current and RF output power (typically less than 10 A max at 300 W). 9. Check drain DC current, RF output power and temperature.
Shutdown: 1. Shut off RF input power. 2. Remove drain DC voltage.

Assembly notes: · Mount all SMT devices on PCB (device values are dependent on frequency
of operation). · Make sure no solder blobs are on non-component side of board. · Trim leads of MRF300AN to shoulder. · Mount board onto baseplate. · Mount device using thermal grease, solder only after tightening device
mounting screw. · Mount connectors and solder center pins. · Connect power wires
Check out our reference designs at www.nxp.com/RFcollection
NXP and the NXP logo are trademarks of NXP B.V. All other product or service names are the property of their respective owners. © 2021 NXP B.V. Document Number: MRF300ANEKITQRC Rev. 0



References

Adobe PDF Library 15.0