UNI-T UDP5000 Series Programmable DC Power Supplies

Data Sheet

Product Overview

The UDP5000 series power supplies feature a compact design, high performance, versatile functionality, a wide output range, user-friendly operation, and flexible usage. The series includes four rated output voltages (40 V, 80 V, 160 V, 250 V) and four rated output power levels (400 W, 800 W, 1200 W, 2000 W), forming a total of 16 models.

Each model is equipped with:

Product Specifications

Model Voltage Output Current Output Output Power
40 V
UDP5040-400-40 V0-40 A400 W
UDP5040-800-80 A800 W
UDP5040-1200-120 A1200 W
UDP5040-2000-200A2000 W
80 V
UDP5080-200-80 V0-20 A400 W
UDP5080-400-40 A800 W
UDP5080-600-60 A1200 W
UDP5080-1000-100 A2000 W
160 V
UDP5160-80-160 V0-8 A400 W
UDP5160-160-16 A800 W
UDP5160-240-24 A1200 W
UDP5160-400-40 A2000 W
250 V
UDP5250-60-250 V0-6 A400 W
UDP5250-120-12 A800 W
UDP5250-180-18 A1200 W
UDP5250-300-30 A2000 W

Features

Design Highlights

1.1 TFT-LCD, Multifunction Buttons

The 2.4-inch TFT-LCD screen delivers a vibrant color display, offering a comfortable visual experience. Intuitive multifunction buttons enhance usability, making operation more convenient.

1.2 Intuitive Setting Interface

The Menu key allows configuration of output, system, and network settings, or viewing product information.

Function Highlights

Slope Mode Setting

To prevent overshoot when output is enabled:

Slope Mode

Slope ModeDescription
CV High-Speed Priority (VHS)Default to high-speed rise and fall rates
CC High-Speed Priority (IHS)
CV Slope Priority (VSR)Rise and fall rates can be set as needed
CC Slope Priority (ISR)

OVP/OCP Settings

Set upper limits for output voltage and current. The output set value cannot exceed 95% of the protection value. The protection value must be at least 105% of the output set value. Configure a delay time for protection activation, adjustable between 10 ms and 10,000 ms.

Auto Rage Function

UDP5000 series limits output voltage and current based on the rated power. As a result, voltage and current automatically adjust proportionally.

List Mode

Users can configure 128 groups of output voltage, current, and output time data combinations. Additionally, the number of cycles and stop status can be configured. Up to 32 data sets can be stored in the power supply's local memory or exported to external devices. Once the list is configured and output is activated, the power supply will automatically execute the programmed combinations.

Discharge Load Function

In the UDP5000 power supplies, a capacitor is connected to the output terminal, and the power supply is equipped with an internal discharge load that discharges the capacitor when the output is turned off. When the discharge load is disabled, a residual voltage that decreases slowly will remain on the output terminals after the output stops. Conversely, when the discharge load is enabled, the residual voltage will disappear rapidly.

Internal Variable Resistance

The internal variable resistance function can adjust the power supply's internal resistance, simulating real power sources such as secondary batteries, solar cells, and fuel cells. The internal variable resistance can only be set in constant voltage mode.

Power Internal Resistance Settings

ModelVrtg[V]Irtg[A]Rint[Ω]Resolution*1Power
UDP5040-4040400.000-1.0000.001400 W
UDP5040-8040800.000-0.5000.001800 W
UDP5040-120401200.000-0.3330.0011200 W
UDP5040-200402000.000-0.2000.0012000 W
UDP5080-2080200.000-4.0000.001400 W
UDP5080-4080400.000-2.0000.001800 W
UDP5080-6080600.000-1.3330.0011200 W
UDP5080-100801000.000-0.8000.0012000 W
UDP5160-816080.000-15.0000.001400 W
UDP5160-16160160.000-7.5000.001800 W
UDP5160-24160240.000-5.0000.0011200 W
UDP5160-40160400.000-3.0000.0012000 W
UDP5250-625060.000-31.2500.001400 W
UDP5250-12250120.000-15.6250.001800 W
UDP5250-18250180.000-10.4160.0011200 W
UDP5250-30250300.000-6.2500.0012000 W

Vrtg[V]: Rated voltage

Irtg[A]: Rated current

Rint[Ω]: Internal resistance

*1. Setting resolution for the power supply's internal resistance.

External Voltage Control

All UDP5000 series models support external analog control and multi-unit combined operation. When using the external analog interface, ensure that the appropriate cable is used for wiring.

For external voltage control, the power supply's operation mode must be set to External Voltage Control.

For detailed instructions, refer to the UDP5000 Series Programmable DC Power Supply-User Manual.

Circuit Connection Diagram

Using an external switch to control power output ON/OFF: By adjusting the ON/OFF state, the power supply output is regulated accordingly.

Adjust an external potentiometer to control the output voltage/current

Adjust Rvs and Ris to regulate the output voltage and current levels.

Rear Panel Analog Interface

Interface | Definition

GND | Ground terminal

VREF_V | The power supply internally provides a 10 V reference voltage for external voltage control output.

Vs/DO | Voltage analog control: Analog voltage setting (0-10 V) corresponds to 0-VoutMax.

Is/D1 | Current analog control: Current voltage setting (0-10 V) corresponds to 0-loutMax.

D2 | External digital control

ON/OFF | External Digital/Analog Control for Power Output ON/OFF: High level: Enables the output; Low level: Disables the output

Vm | Voltage output analog channel (0-10 V) corresponds to 0-VoutMax.

Im | Current output analog channel (0-10 V) corresponds to 0-loutMax.

NC | Not connected (not in use)

EN_BUS | Coordinates and synchronizes start/stop, protection, and operation modes in multi-unit series/parallel operation, ensuring stable and reliable collaboration between units.

Series/Parallel Operation

UDP5000 series power supplies support external multi-unit combined operation with identical models to increase output power. This includes both external multi-unit parallel and external multi-unit series connections.

Before use, select and configure a master unit and slave units, then connect the analog interfaces using the appropriate cables.

Single-control operation refers to setting one instrument as the master unit, while other identical models function as slave units. The entire system can then be controlled through operations on the master unit.

Single-Control Parallel Operation

Single-control parallel operation increases the output current. Maximum output current (loutMax) = Rated output current of power supply x Number of parallel-connected units. For example, if three UDP5040-40 models are paralleled, the output current can reach 40 A × 3 = 120 A. The difference in output current between the master unit and slave units must remain within approximately 5% of the rated value.

For single-control parallel operation, the maximum number of identical models that can be paralleled (including the master unit) is as shown in the following table:

ModelMaximum Parallel-Connected Units
400 W4 Units
800 W4 Units
1200 W2 Units
2000 W2 Units

Single-Control Series Operation

Single-control series operation increases the output voltage. Maximum output voltage (Voutmax)= Rated output voltage of power supply x Number of series-connected units. For example, if two UDP5250-6 models are series-connected, the maximum voltage can reach 250 V x 2=500 V.

Maximum Series-Connected Units: 2

The voltage setting accuracy is equivalent to the single-unit accuracy of the master unit. The difference in output voltage between the master unit and slave units must remain within approximately 5% of the rated value.

ModelMaximum Series-Connected Units
400 W2 Units
800 W2 Units
1200 W2 Units
2000 W2 Units

Technical Specifications

Specification Conditions

This section outlines the technical specifications for the 400 W, 800 W, 1200 W, and 2000 W models of the UDP5000 series. It includes detailed information on input/output specifications, voltage and current specifications, output characteristics, noise and ripple, and display characteristics.

Unless otherwise specified, technical specifications are based on the following settings and conditions (applicable to all models):

Technical Terminology

3.1 400 W Model

AC Input Characteristics

Specification/ModelUDP5040-40UDP5080-20UDP5160-8UDP5250-6
AC Input100 Vac - 240 Vac, 50Hz - 60Hz, single-phase
Nominal input rating85 Vac to 265 Vac
Input Voltage Range47 Hz to 63 Hz
Input Voltage Frequency Range100 Vac200 Vac
Current (Typ.)*15.6 A2.8 A
Surge Current (MAX) *2Below 25 Apeak
Power (MAX)*3560 W
Power Factor (Typ.)*10.99 (Input voltage: 100 V), 0.97 (Input voltage: 200 V)
Efficiency (MIN)*175% (Typ.)
Output Hold Time (MIN)*3Above 20 ms

*1. Rated output current at output rated power.

*2. After the power switch is turned on (within approximately 1 ms), the charge current component that flows through the internal EMC filter circuit capacitor is not included.

*3. At output rated power.

Output Characteristics

Specification/ModelUDP5040-40UDP5080-20UDP5160-8UDP5250-6
Output Voltage*140 V80 V160 V250 V
Rated ValueOutput Current*140 A20 A8 A6 A
Output Power400 W
Maximum Adjustable Voltage *242 V84 V168 V262.5 V
Output Accuracy *3±(0.05% of the set value + 0.05% of the rated value)
Setting Resolution1 mV1mV10 mV10 mV
Display Resolution1 mV1mV1 mV (<100 V)
10 mV (≥100 V)
1 mV (<100 V)
10 mV (≥100 V)
Power Regulation*4±6 mV±10 mV±12.2 mV±26 mV
Load Regulation*5±6 mV±10 mV±12.2 mV±26 mV
Ripple and Noise *6p-p*750 mV100 mV100 mV100 mV
Voltagerms*75 mV12 mV20 mV20 mV
Rise TimeRated LoadBelow 50 msBelow 100 msBelow 100 msBelow 100 ms
No LoadBelow 50 msBelow 100 msBelow 100 msBelow 100 ms
Fall TimeRated LoadBelow 50 ms150 ms250 ms250 ms
No LoadBelow 500 ms1200 ms2000 ms2000 ms
Maximum Remote Sense Compensation Voltage (MAX)1.5 V4 V5 V5 V
Temperature Coefficient*8100 ppm/°C
Maximum Adjustable Current*242 A21 A8.4 A6.3 A
Output Accuracy*9±(0.5% of the set value + 0.1% of the rated value)
Setting Resolution1 mA1 mA1 mA1 mA
Display Resolution1 mA1 mA1 mA1 mA
Power Regulation*4±6 mA±4 mA±3 mA±2.5 mA
CurrentLoad Regulation*5±13 mA±9 mA±7 mA±6 mA
Ripple and Noise*6rms*780 mA40 mA30 mA12 mA
Rise Time (Typ.)Rated Load50 ms100 ms100 ms100 ms
Fall Time (Typ.)Rated Load50 ms100 ms100 ms100 ms
Temperature Coefficient*8100 ppm/°C
Maximum Adjustable Internal Resistance1.000 Ω4.000 Ω15 Ω31.25 Ω

*1. The maximum output voltage and maximum output current are constrained by the maximum output power.

*2. OVP and OCP limits are set at approximately 95%.

*3. Applies to a 1% to 100% range of the rated voltage.

*4. For input voltages of 90 VAC to 121 VAC or 198 VAC to 242 VAC under constant load.

*5. When the power supply outputs the rated voltage and operates from no-load to rated load (i.e., outputs the rated current), voltage regulation is calculated as: Output Voltage Regulation= (Load Voltage at No-Load Current - Load Voltage at Rated Load Current) ÷ Load Voltage at Full Load Current ×100%

*6. In constant voltage mode, with the power supply delivering the rated current at rated power, measure the ripple and noise at the output using an oscilloscope

*7. Measurement bandwidth: 20 MHz.

*8. Ambient temperature range: 0°C to 50°C.

*9. Applies to a 1% to 100% range of the rated current. For 0% to 1%, values are typical (Typ.)

Display Characteristics

Specification/ModelUDP5040-40UDP5080-20UDP5160-8UDP5250-6
Maximum Display99.99999.999999.99999.99
Voltage DisplayMinimum Display*10.1000.1000.500.50
Display Accuracy1 mV1mV1 mV (<100 V)
10 mV (≥100 V)
1 mV (<100 V)
10 mV (≥100 V)
Current DisplayMaximum Display99.99999.9999.9999.999
Display Accuracy1 mA1 mA1 mA1 mA
Power DisplayMaximum Display999.99999.99999.99999.99
Display Accuracy1 mW (<100 W), 10 mW (≥100 W)

*1. For the 5040 and 5080 models, the output voltage is 0.1 V, while for the 5160 and 5250 models, the output voltage is 0.5 V.

3.2 800 W Model

AC Input Characteristics

Specification/ModelUDP5040-80UDP5080-40UDP5160-16UDP5250-12
AC Input100 Vac - 240 Vac, 50Hz - 60Hz, single-phase
Nominal input rating85 Vac to 265 Vac
Input Voltage Frequency Range47 Hz to 63 Hz
Current (Typ.)*111.2 A5.6 A
Surge Current (MAX) *2Below 50 Apeak
Power (MAX)*31120 W
Power Factor (Typ.)*10.99 (Input voltage: 100 V), 0.97 (Input voltage: 200 V)
Efficiency (MIN)*175% (Typ.)
Output Hold Time (MIN)*3Above 20 ms

*1. Rated output current at output rated power.

*2. After the power switch is turned on (within approximately 1 ms), the charge current component that flows through the internal EMC filter circuit capacitor is not included.

*3. At output rated power.

Output Characteristics

Specification/ModelUDP5040-80UDP5080-40UDP5160-16UDP5250-12
Output Voltage*140 V80 V160 V250 V
Rated ValueOutput Current*180A40 A16 A12 A
Output Power800 W
Maximum Adjustable Voltage *242 V84 V168 V262.5 V
Output Accuracy*3±(0.05% of the set value + 0.05% of the rated value)
Setting Resolution1mV1 mV10 mV10 mV
Display Resolution1mV1mV1 mV (<100 V)
10 mV (≥100 V)
1 mV (<100 V)
10 mV (≥100 V)
Power Regulation*4±6 mV±10 mV±20 mV±26 mV
Load Regulation*5±6 mV±10 mV±20 mV±26 mV
Ripple and Noise *6p-p*750 mV100 mV100 mV100 mV
Voltagerms*75 mV12 mV20 mV20 mV
Rise TimeRated LoadBelow 50 msBelow 100 msBelow 100 msBelow 100 ms
No LoadBelow 50 msBelow 100 msBelow 100 msBelow 100 ms
Fall TimeRated LoadBelow 50 ms150 ms250 ms250 ms
No LoadBelow 500 ms1200 ms2000 ms2000 ms
Maximum Remote Sense Compensation Voltage (MAX)1.5 V4 V5 V5 V
Temperature Coefficient*8100 ppm/°C
Maximum Adjustable Current*284A42 A16.8 A12.6 A
Output Accuracy*9±(0.5% of the set value + 0.1% of the rated value)
Setting Resolution1 mA1 mA1 mA1 mA
Display Resolution1 mA1 mA1 mA1 mA
Power Regulation*4±10 mA±6 mA±5 mA±3 mA
CurrentLoad Regulation*5±21 mA±13 mA±10 mA±7 mA
Ripple and Noise*6rms*7160 mA80 mA40 mA24 mA
Rise Time (Typ.)Rated Load50 ms100 ms100 ms100 ms
Fall Time (Typ.)Rated Load50 ms100 ms100 ms100 ms
Temperature Coefficient*8100 ppm/°C
Maximum Adjustable Internal Resistance0.500 Ω2.000 Ω7.5 Ω15.625 Ω

*1. The maximum output voltage and maximum output current are constrained by the maximum output power.

*2. OVP and OCP limits are set at approximately 95%.

*3. Applies to a 1% to 100% range of the rated voltage.

*4. For input voltages of 90 VAC to 121 VAC or 198 VAC to 242 VAC under constant load.

*5. When the power supply outputs the rated voltage and operates from no-load to rated load (i.e., outputs the rated current), voltage regulation is calculated as: Output Voltage Regulation= (Load Voltage at No-Load Current - Load Voltage at Rated Load Current) ÷ Load Voltage at Full Load Current ×100%

*6. In constant voltage mode, with the power supply delivering the rated current at rated power, measure the ripple and noise at the output using an oscilloscope

*7. Measurement bandwidth: 20 MHz.

*8. Ambient temperature range: 0°C to 50°C.

*9. Applies to a 1% to 100% range of the rated current. For 0% to 1%, values are typical (Typ.)

Display Characteristics

Specification/ModelUDP5040-80UDP5080-40UDP5160-16UDP5250-12
Maximum Display99.99999.999999.99999.99
Voltage DisplayMinimum Display*10.1000.1000.500.50
Display Accuracy1 mV1mV1 mV (<100 V)
10 mV (≥100 V)
1 mV (<100 V)
10 mV (≥100 V)
Current DisplayMaximum Display99.99999.99999.99999.999
Display Accuracy1 mA1 mA1 mA1 mA
Power DisplayMaximum Display999.99999.99999.99999.99
Display Accuracy1 mW (<100 W), 10 mW (≥100 W)

*1. For the 5040 and 5080 models, the output voltage is 0.1V, while for the 5160 and 5250 models, the output voltage is 0.5 V.

3.3 1200 W Model

AC Input Characteristics

Specification/ModelUDP5040-120UDP5080-60UDP5160-24UDP5250-18
AC Input100 Vac - 240 Vac, 50Hz - 60Hz, single-phase
Nominal input rating85 Vac to 265 Vac
Input Voltage Frequency Range47 Hz to 63 Hz
Current (Typ.)*116.8 A8.4 A
Surge Current (MAX) *2Below 75 Apeak
Power (MAX)*31680 W
Power Factor (Typ.)*10.99 (Input voltage: 100 V), 0.97 (Input voltage: 200 V)
Efficiency (MIN)*175% (Typ.)
Output Hold Time (MIN)*3Above 20 ms

*1. Rated output current at output rated power.

*2. After the power switch is turned on (within approximately 1 ms), the charge current component that flows through the internal EMC filter circuit capacitor is not included.

*3. At output rated power.

Output Characteristics

Specification/ModelUDP5040-120UDP5080-60UDP5160-24UDP5250-18
Output Voltage*140 V80 V160 V250 V
Rated ValueOutput Current*1120 A60 A24 A18 A
Output Power1200 W
Maximum Adjustable Voltage *242 V84 V168 V262.5 V
Output Accuracy*3±(0.05% of the set value + 0.05% of the rated value)
Setting Resolution1mV1mV10 mV10 mV
Display Resolution1mV1 mV1 mV (<100 V)
10 mV (≥100 V)
1 mV (<100 V)
10 mV (≥100 V)
Power Regulation*4±6 mV±10 mV±20 mV±26 mV
Load Regulation*5±6 mV±10 mV±20 mV±26 mV
Ripple and Noise *6p-p*750 mV100 mV100 mV100 mV
Voltagerms*75 mV12 mV20 mV20 mV
Rise TimeRated LoadBelow 50 msBelow 100 msBelow 100 msBelow 100 ms
No LoadBelow 50 msBelow 100 msBelow 100 msBelow 100 ms
Fall TimeRated LoadBelow 50 ms150 ms250 ms250 ms
No LoadBelow 500 ms1200 ms2000 ms2000 ms
Maximum Remote Sense Compensation Voltage (MAX)1.5 V4 V5 V5 V
Temperature Coefficient*8100 ppm/°C
Maximum Adjustable Current*2126 A63 A25.2 A18.9 A
Output Accuracy*9±(0.5% of the set value + 0.1% of the rated value)
Setting Resolution10 mA1 mA1 mA1 mA
Display Resolution1 mA1 mA1 mA1 mA
Power Regulation*4±14 mA±8 mA±6 mA±3.5 mA
CurrentLoad Regulation*5±29 mA±17 mA±12 mA±8.0 mA
Ripple and Noise*6rms*7240 mA120 mA60 mA36 mA
Rise Time (Typ.)Rated Load50 ms100 ms100 ms100 ms
Fall Time (Typ.)Rated Load50 ms100 ms100 ms100 ms
Temperature Coefficient*8100 ppm/°C
Maximum Adjustable Internal Resistance0.333 Ω1.333 Ω5.00 Ω10.416 Ω

*1. The maximum output voltage and maximum output current are constrained by the maximum output power.

*2. OVP and OCP limits are set at approximately 95%.

*3. Applies to a 1% to 100% range of the rated voltage.

*4. For input voltages of 90 VAC to 121 VAC or 198 VAC to 242 VAC under constant load.

*5. When the power supply outputs the rated voltage and operates from no-load to rated load (i.e., outputs the rated current), voltage regulation is calculated as: Output Voltage Regulation= (Load Voltage at No-Load Current - Load Voltage at Rated Load Current) ÷ Load Voltage at Full Load Current ×100%

*6. In constant voltage mode, with the power supply delivering the rated current at rated power, measure the ripple and noise at the output using an oscilloscope

*7. Measurement bandwidth: 20 MHz.

*8. Ambient temperature range: 0°C to 50°C.

*9. Applies to a 1% to 100% range of the rated current. For 0% to 1%, values are typical (Typ.)

Display Characteristics

Specification/ModelUDP5040-120UDP5080-60UDP5160-24UDP5250-18
Maximum Display99.99999.999999.99999.99
Voltage DisplayMinimum Display*10.1000.1000.500.50
Display Accuracy1mV1mV1 mV (<100 V)
10 mV (≥100 V)
1 mV (<100 V)
10 mV (≥100 V)
Current DisplayMaximum Display99.99999.99999.99999.999
Display Accuracy1 mA (<100 A)
10 mA (≥100 A)
1 mA1 mA1 mA
Power DisplayMaximum Display999.99999.99999.99999.99
Display Accuracy1 mW (<100 W), 10 mW (≥100 W)

*1. For the 5040 and 5080 models, the output voltage is 0.1V, while for the 5160 and 5250 models, the output voltage is 0.5 V.

3.4 2000 W Model

AC Input Characteristics

Specification/ModelUDP5040-200UDP5080-100UDP5160-40UDP5250-30
AC Input100 Vac - 240 Vac, 50Hz - 60Hz, single-phase
Nominal input rating85 Vac to 265 Vac
Input Voltage Frequency Range47 Hz to 63 Hz
Current (Typ.)*128 A14 A
Surge Current (MAX) *2Below 125 Apeak
Power (MAX)*32800 W
Power Factor (Typ.)*10.99 (Input voltage: 100 V), 0.97 (Input voltage: 200 V)
Efficiency (MIN)*175% (Typ.)
Output Hold Time (MIN)*3Above 20 ms

*1. Rated output current at output rated power.

*2. After the power switch is turned on (within approximately 1 ms), the charge current component that flows through the internal EMC filter circuit capacitor is not included.

*3. At output rated power.

Output Characteristics

Specification/ModelUDP5040-200UDP5080-100UDP5160-40UDP5250-30
Output Voltage*140 V80 V160 V250 V
Rated ValueOutput Current*1200 A100 A40 A30 A
Output Power2000 W
Maximum Adjustable Voltage *242 V84 V168 V262.5 V
Output Accuracy*3±(0.05% of the set value + 0.05% of the rated value)
Setting Resolution1 mV1 mV10 mV10 mV
Display Resolution1mV1mV1 mV (<100 V)
10 mV (≥100 V)
1 mV (<100 V)
10 mV (≥100 V)
Power Regulation*4±6 mV±10 mV±20 mV±26 mV
Load Regulation*5±6 mV±10 mV±20 mV±26 mV
Ripple and Noise *6p-p*750 mV100 mV100 mV100 mV
Voltagerms*75 mV12 mV20 mV20 mV
Rise TimeRated LoadBelow 50 msBelow 100 msBelow 100 msBelow 100 ms
No LoadBelow 50 msBelow 100 msBelow 100 msBelow 100 ms
Fall TimeRated LoadBelow 50 ms150 ms250 ms250 ms
No LoadBelow 500 ms1200 ms2000 ms2000 ms
Maximum Remote Sense Compensation Voltage (MAX)1.5 V4 V5 V5 V
Temperature Coefficient*8100 ppm/°C
Maximum Adjustable Current*2210 A105 A42 A31.5 A
Output Accuracy*9±(0.5% of the set value + 0.1% of the rated value)
Setting Resolution10 mA10 mA1 mA1 mA
Display Resolution1 mA (<100 A)
10 mA (≥100 A)
1 mA (<100 A)
10 mA (≥100 A)
1 mA1 mA
Power Regulation*4±22 mA±12 mA±8 mA±4.5 mA
CurrentLoad Regulation*5±45 mA±25 mA±18 mA±10.0 mA
Ripple and Noise*6rms*7400 mA200 mA100 mA60 mA
Rise Time (Typ.)Rated Load50 ms100 ms100 ms100 ms
Fall Time (Typ.)Rated Load50 ms100 ms100 ms100 ms
Temperature Coefficient*8100 ppm/°C
Maximum Adjustable Internal Resistance0.20 Ω0.800 Ω3.00 Ω6.250 Ω

*1. The maximum output voltage and maximum output current are constrained by the maximum output power.

*2. OVP and OCP limits are set at approximately 95%.

*3. Applies to a 1% to 100% range of the rated voltage.

*4. For input voltages of 90 VAC to 121 VAC or 198 VAC to 242 VAC under constant load.

*5. When the power supply outputs the rated voltage and operates from no-load to rated load (i.e., outputs the rated current), voltage regulation is calculated as: Output Voltage Regulation= (Load Voltage at No-Load Current – Load Voltage at Rated Load Current) ÷ Load Voltage at Full Load Current ×100%

*6. In constant voltage mode, with the power supply delivering the rated current at rated power, measure the ripple and noise at the output using an oscilloscope

*7. Measurement bandwidth: 20 MHz.

*8. Ambient temperature range: 0°C to 50°C.

*9. Applies to a 1% to 100% range of the rated current. For 0% to 1%, values are typical (Typ.)

Display Characteristics

Specification/ModelUDP5040-200UDP5080100UDP5160-40UDP5250-30
Maximum Display99.99999.999999.99999.99
Voltage DisplayMinimum Display™™0.1000.1000.500.50
Display Accuracy1 mV1mV1 mV (<100 V)
10 mV (≥100 V)
1 mV (<100 V)
10 mV (≥100 V)
Current DisplayMaximum Display999.99999.9999.99999.999
Display Accuracy1 mA (<100 A)
10 mA (≥100 A)
1 mA (<100 A)
10 mA (≥100 A)
1 mA1 mA
Power DisplayMaximum Display999.99999.99999.99999.99
Display Accuracy1 mW (<100 W), 10 mW (≥100 W)

*1. For the 5040 and 5080 models, the output voltage is 0.1V, while for the 5160 and 5250 models, the output voltage is 0.5 V.

3.5 Common Specifications

Protection Function

Specification/Model400 W Model800 W Model1200 W Model2000 W Model
Protection Function
Over-Voltage Protection (OVP)Automatically turns off*¹ when triggered, and a window display: "OVP is triggered, the output will be turned off."
Setting Range0% to 105% of the rated output voltage.
Setting Accuracy1 mV (for single-unit rated values < 100 V)
10 mV (for single-unit rated values ≥ 100 V)
Over-Current Protection (OCP)*2Automatically turns off*¹ when triggered, and a window display: "OCP is triggered, the output will be turned off."
Adjustable Range0% to 105% of the rated output current.
Adjustable Accuracy1 mA (for single-unit rated values < 100 A)
10 mA (for single-unit rated values ≥ 100 A
Front Output Terminal Over-Current Protection (FOCP)*3Automatically turns off*¹ when triggered, and a window display: "FOCP is triggered, the output will be turned off."
Value (fixed)> 10A (Typ.)
Over-Temperature Protection (OTP)Automatically turns off*¹ when triggered, and a window display: "OTP is triggered, the output will be turned off."
Shutdown (SD)Turn off the power supply
Power LimitAutomatically turns off*¹ when triggered, and a window display: "Power limit is triggered, the output will be turned off."
Value (fixed)Close to 105% of the rated output power.
Communication Monitoring (Watchdog)Restarts automatically, and a window display: "The watchdog failed. It will automatically restart."
Single-Control Series/Parallel Operation Protection (PRL ALM)Automatically turns off the output, and a window display: "Master/slave failed, the output will be turned off."

*1. For 2000 W models, this may result in output disconnection or circuit breaker tripping.

*2. This does not prevent peak discharge currents in the internal capacitors of the UDP5000 power supply's output section during sudden load changes.

*3. The front-panel output current is limited to a maximum of 10 A. Values exceeding 10 A will trigger protection. If the OCP (Over-Current Protection) threshold is lower than the FOCP (Fast Over-Current Protection) threshold, OCP takes precedence.

Signal Input/Output

Specification/Model400 W Model800 W Model1200 W Model2000 W Model
Signal Input/Output
MonitoringVoltage Monitor (VMON)Voltage Monitor Range: 0 V to 10 V
Signal OutputCurrent Monitor (IMON)*1Voltage Monitor Range: 0 V to 10 V
Output StateThis function is enabled when the power supply output is active.
State OutputCV ModeThis function is enabled when the power supply operates in constant voltage (CV) mode.
CC ModeThis function is enabled when the power supply operates in constant current (CC) mode.
Alarm StateThis function is enabled when an alarm is triggered.
Power StatePower State: The power is on when the switch is turned on.
Input (Trigger Input)Logic: Low level (0 V to 1.5 V), high level (3.5 V to 5 V)
Input resistance: 10 ΚΩ (Typ.)
Trigger SignalLogic: Low level (0 V to 0.6 V), high level (4.2 V to 5 V)
Output (Trigger Output)Pulse Width: 100 µs (Typ.)

*1. Control the voltage on the current sampling path to regulate the output current.

Control Function

Specification/Model400 W Model800 W Model1200 W Model2000 W Model
Control Functions
Output Voltage Control (VPGM)0% to 100% of the rated output voltage
Voltage Control Range: 0 V to 10 V
Accuracy±5%
External Voltage Control Output Current Control (IPGM)0% to 100% of the rated output voltage
Voltage Control Range: 0 V to 10 V
Accuracy±5%

Output ON/OFF Control: When the switch is closed, a high-level signal enables the output. When the switch is open, a low-level signal disables the output.

Other Functions

Specification/Model400 W Model800 W Model1200 W Model2000 W Model
Other Functions
Output ON/OFF DelayerSetting Range: 0.1 s to 9999.9 s*¹
Resolution: 0.1s, 1 s, 10 s, 100 s, 1000 s, 10000 s
OVP/OCP Enable Delayer *2Setting Range: 10 ms to 10000 ms
Resolution: 10 ms, 100 ms
Preset ValueGroup Number: 32*3 groups
Keypad LockUnlocks all keys except the Output key
List ModeSetting Group: 0 to 128 groups
Cycle Count: 1 to 9,999, infinite*3
Synchronous Operation ModeStep Time: 0.1 s to 99,999.9 s
Synchronizes voltage and current settings, recovery steps, and sequence execution in a P-sequence program.
Multi-Unit External Parallel Operation Mode *4Supports up to four parallel-connected units (same model), including the master unit.Supports up to two parallel-connected units (same model), including the master unit.
Multi-Unit External Series ModeSupports up to two series-connected units (same model).
Multi-Communication (VMCB)Master Connects to PC: Ethernet, USB
Master Connects to Slave: CAN

*1. Factory default setting is 0.1 s.

*2. Factory default setting is 10 ms.

*3. Set it to 0 for infinite loop.

*4. The difference between the master and slave is 5% (Typ.)

Operation Display

Specification/Model400 W Model800 W Model1200 W Model2000 W Model
Operation Display
Output ON/OFFThe Output button lights up green when the output is active.
CV OperationThe display shows "CV" in green when in constant voltage mode.
CC OperationThe display shows "CC" in red when in constant current mode.
AlarmWhen a protective function is activated, a window displays detailed error information and automatically turns off the output
Key LockThe Lock button lights up green when locked.
Remote ControlThe operation mode is displayed as "External Control."

Interface

Specification/Model400 W Model800 W Model1200 W Model2000 W Model
Interface
General SpecificationSoftware ProtocolIEEE Std 488.2-1992
CommandSCPI Specification 1999.0
HardwareUSBUSB 2.0
Data Rate: 480 Mbps (high speed)
B-type outlet
Receiving: The program message terminator is LF (Line Feed) or EOM.
Sending: The program message terminator is LF and +EOM.
Device CategoryUSBTMC-USB48
HardwareLANIEEE 802.3 100Base-TX/10Base-T
LXI 2011 Ver.1.4
LXI HISLIP Rev.1.01
IPv4, RJ-45 connector
VXI-11, SCPI-RAW, HISLIP
For VXI-11 and HiSLIP: When receiving, the message terminator can be LF or END.
For SCPI-RAW: When receiving, the terminator is a low-level signal. When transmitting, the terminator is also a low-level signal.

General Specifications

Specification/Model400 W Model800 W Model1200 W Model2000 W Model
Dimensions
Weight (Main Unit Only)Approx. 3 kgApprox. 5.5 kgApprox. 7.5 kgApprox.13 kg
DimensionsRefer to the outline dimension drawing.
Environmental ConditionsOperating EnvironmentIndoor use, Overvoltage Category II
Operating Temperature0°C to +50°C
Operating Humidity20% R.H to 85% R.H (non-condensing)
Storage Temperature-20°C to +60°C
Storage Humidity90% R.H or below (non-condensing)

Cooling MethodFan-forced air cooling
AltitudeBelow 2000 meters
Grounding PolarityBoth positive ground and negative ground
Grounding VoltageApplicable models: UDP5040, UDP5080, UDP5160, and UDP5250
Maximum: ±500 Vmax
Voltage WithstandThrough Main Circuit and Chassis1500 VAC applied for 1 minute with no abnormalities.
Through Main Circuit and Secondary CircuitUDP5040, UDP5080, UDP5160, and UDP5250 models: 1650 VAC applied for 1 minute with no abnormalities.
Insulation ResistanceThrough Main Circuit and Secondary Circuit Across Secondary Circuit and Chassis100 ΜΩ or more (at ≤70% R.H), measured at 500 VDC.
UDP5040, UDP5080, UDP5160, and UDP5250 models: 100 ΜΩ or more (at ≤70% R.H), measured at 500 VDC.
UDP5040, UDP5080, UDP5160, and UDP5250 models: 40 ΜΩ or more (at ≤70% R.H), measured at 500 VDC.
Electro Magnetic Compatibility (EMC)*1*2EMC 2014/30/EU
EN61326-1(Class A*3)
EN55011(Class A*3, Group I)
EN61000-3-2
EN61000-3-3
Applicable Conditions:
Cables and wires connected to this product must be ≤3 meters in length.
Safety *1Low Voltage Directive 2014/35/EU*2
EN61010-1(Class I*4, Pollution degree 2*5)

*1. Not applicable to customized or modified products.

*2. Applies only to products with the CE marking.

*3. Class A device: Designed for industrial environments. Operation in residential areas may cause interference. To prevent radio/TV signal disruption, users should implement measures to reduce electromagnetic emissions if necessary.

*4. Class I device: Requires proper grounding of the protective earth terminal. Proper grounding is essential for safety compliance.

*5. Pollution Degree 2: Defined as non-conductive pollution (e.g., dust, oil mist) that may temporarily become conductive due to condensation, reducing insulation withstand capacity and surface resistivity.

Limited Warranty and Liability

UNI-T guarantees that the Instrument product is free from any defect in material and workmanship within three years from the purchase date. This warranty does not apply to damages caused by accident, negligence, misuse, modification, contamination, or improper handling. If you need a warranty service within the warranty period, please contact your seller directly. UNI-T will not be responsible for any special, indirect, incidental, or subsequent damage or loss caused by using this device. For the probes and accessories, the warranty period is one year. Visit instrument.uni-trend.com for full information.

Learn more at: www.uni-trend.com

UNI-T is the licensed trademark of UNI-TECHNOLOGY (CHINA) CO., Ltd.

Register your product to confirm your ownership. You will also get product notifications, update alerts, exclusive offers and all the latest information you need to know.

UNI-T products are protected under patent laws in China and internationally, covering both granted and pending patents. Licensed software products are the properties of UNI-Trend and its subsidiaries or suppliers, all rights reserved. This manual contains information that replaces all earlier published versions. The product information in this document subject to update without notice. For more information on UNI-T Test & Measure Instrument products, applications, or service, please contact UNI-T instrument for support, the support center is available on www.uni-trend.com ->instruments.uni-trend.com

https://instruments.uni-trend.com/ContactForm/

Headquarter

UNI-TREND (CHINA) CO., Ltd.
Address: No.6, Industrial North 1st Road, Songshan Lake Park, Dongguan City, Guangdong Province, China
Tel: (86-769) 8572 3888

Europe

UNI-TREND TECHNOLOGY EU GmbH
Address: Affinger Str. 12
86167 Augsburg Germany
Tel: +49 (0) 821 8879980

North America

UNI-TREND TECHNOLOGY US INC.
Address: 3171 Mercer Ave STE 104, Bellingham, WA 98225
Tel: +1-888-668-8648

PDF preview unavailable. Download the PDF instead.

081334d21298e3876a883aa400174 Microsoft Word 2013

Related Documents

Preview UNI-T UDP5000 Series Programmable DC Power Supplies User Manual
User manual for the UNI-T UDP5000 Series Programmable DC Power Supplies. This manual provides detailed information on product overview, features, specifications, safety instructions, and installation procedures for these versatile DC power supplies.
Preview UNI-T UDP5000 Series Programmable DC Power Supplies QuickStart Guide
This guide provides a quick start to using the UNI-T UDP5000 Series Programmable DC Power Supplies, covering product overview, features, basic configuration, key functions, troubleshooting, and advanced operations like parallel and series connections, and remote control.
Preview UNI-T UDP3305S-U Programmable DC Power Supply Datasheet
Datasheet for the UNI-T UDP3305S-U Programmable DC Power Supply, detailing its features, technical specifications, and applications in research, industry, and education. Discover its multi-channel output, high precision, and connectivity options.
Preview UNI-T UDP3303C-U Linear DC Power Supply User Manual
This user manual provides comprehensive instructions for the UNI-T UDP3303C-U Linear DC Power Supply, covering its features, specifications, safety guidelines, operation, and maintenance. It details how to set voltage and current, use series and parallel modes, manage protection features, and utilize various interfaces like USB and RS232.
Preview UNI-T UDP3303C-U Linear DC Power Supply User Manual
User manual for the UNI-T UDP3303C-U Linear DC Power Supply, detailing its features, specifications, operation, and safety guidelines.
Preview UDP3305S-U Programmable DC Power Supply User Manual
This user manual provides comprehensive instructions for the UDP3305S-U Programmable DC Power Supply, covering its features, specifications, front and rear panel operations, inspection, installation, preparation for start-up, and advanced functions like list mode, delayer, preset, monitor, and trigger.
Preview UNI-T UDP4303S Programmable Linear DC Power Supply User's Manual
Comprehensive user's manual for the UNI-T UDP4303S Programmable Linear DC Power Supply, covering features, operation, safety, and technical specifications.
Preview UDP5000 Series Programmable Digital Power Supply SCPI Programming Manual
This manual provides comprehensive SCPI programming instructions for the UNI-T UDP5000 Series Programmable Digital Power Supply, covering command formats, parameters, and various functions for controlling and monitoring the power supply.