User Manual for Sunco Lighting models including: VT_DU-WH-3550K, VT2_25SW-GR-3550K, VT8_90SW-GR-3550K, VT Series LED Selectable Vapor Tight Fixture, VT Series, LED Selectable Vapor Tight Fixture, Vapor Tight Fixture, Tight Fixture
4ft LED Vapor Tight Fixture, 54W/46W/38W, Selectable Wattage & CCT, 70 – Sunco Lighting
Installation Guides, Manuals, and Specs | Sunco – Sunco Lighting
Lighting made better. User Manual LED Selectable Vapor Tight Fixture VT_DU-WH-3550K VT2_25SW-GR-3550K VT8_90SW-GR-3550K support@sunco.com (844) 334-9938 What's in the Box? Vapor Light Le(tlittheerraellbye) light! (A) x2 V-Hook (B) x2 Mounting Bracket (C) x2 Plastic Anchor (D) x2 Mounting Screws (E) x2 (F) x2 Metal Gasket (4*12*0.7) Rubber Gasket (4*12*1) (G) x1 Waterproof Cable Gland Get Your Gear (H) x1 Sealing Ring (I) x1 Hex Nut Drill Screwdriver Ladder Wire Strippers 1 Before You Start Safety Information To reduce the risk of fire, electric shock, or physical injury: · Turn off power before changing fixture. · All electrical connections must be in accordance · Suitable for use in damp environments at with local and National Electric Code (N.E.C.) temperatures ranging from 40°F to 122°F. Not for standards. use where directly exposed to water. · Please review installation manual carefully before · Not intended for use with emergency fixtures. proceeding. Consult a qualified electrician if you · Not compatible with photo controls. are unfamiliar with proper electrical wiring · Not compatible with occupancy sensors. connections. · Not compatible with 3rd party sensors. · Not compatible with timing devices. WARNING: Cancer & Reproductive Harm- www.P65Warnings.ca.gov · Not compatible with all dimmers. For more dimming information, please visit www.sunco.com. This device complies with Part 15 of the FCC rules. 2.) This device must accept any interference that Operation is subject to the following two conditions: may cause undesired operation. Please review all 1.) This device may not cause harmful interference. instructions carefully prior to installation. Product size 23.6'' 3.1'' 47.2'' 3.1'' 94.5'' 3.1'' 2 Installation Guide (Surface Mount) STEP 1 a. Turn off circuit breaker. STEP 2 a. Locate area to hang light fixture, then position to on ceiling. b. Determine proper spacing for vapor tight size (approximate): (C) (C) · 2FT: 10.5 16.25" apart · 4FT: 30 35.75" apart · 8FT: 75.25 80.75" apart c. Mark each side, drill pilot hole to marked areas, then insert plastic anchors (C). STEP 3 a. Attach mounting brackets (B) to the ceiling surface with mounting screws (D) and gaskets (E + F). (B) b. Screw mounting screws (D) until mounting bracket (F) is firmly in place. (E) (D) 3 Installation Guide (Surface Mount) STEP 4 Press fixture housing to the mounting brackets (B) until both sides of the housing recesses are secured. (B) (1)Wattage (2)CCT STEP 5 a. Release latches by pulling metal latches away from housing. b. Select desired wattage (1) and CCT (2) using the switches inside fixture. 4 Installation Guide (Surface Mount) (G) (H) (I) STEP 6 a. Install waterproof cable gland (G) on opening of fixture, feed supply wires through it, then connect wires together: · Black to Black (Live) · White to White (Live) · Green to Bare Copper (Ground). b. Optional: To use dimming features, connect dimming wires together: · Pink to Pink · Purple to Purple STEP 7 a. Reattach LED tray and lens back to the fixture. b. Secure lens to housing with lens latches. c. Turn on circuit breaker and test light. 5 Installation Guide (Hanging Mount) STEP 1 a. Turn off circuit breaker. STEP 2 a. Locate area to hang light fixture, then position to on ceiling. b. Determine proper spacing for vapor tight size (C) (C) (approximate): · 2FT: 10.5 16.25" apart · 4FT: 30 35.75" apart · 8FT: 75.25 80.75" apart c. Mark each side, drill pilot hole to marked areas, then insert plastic anchors (C). 6 Installation Guide (Hanging Mount) (A) (B) STEP 3 a. Attach V-Hooks (A) to each mounting bracket (B) by spreading ends of V-Hooks (A), then insert legs into holes of mounting bracket (B). b. Press fixture housing to mounting brackets (B) until both sides of housing recesses are secured. c. Hang fixture from ceiling with hanging equipment (not included) using V-Hooks installed on mounting brackets (B). (1)Wattage (2)CCT STEP 4 a. Release latches by pulling metal latches away from housing. b. Select desired wattage (1) and CCT (2) using the switches inside fixture. 7 Installation Guide (Hanging Mount) (G) (H) (I) STEP 5 a. Install waterproof cable gland (G) on opening of fixture, feed supply wires through it, then connect wires together: · Black to Black (Live) · White to White (Live) · Green to Bare Copper (Ground). b. Optional: To use dimming features, connect dimming wires together: · Pink to Pink · Purple to Purple STEP 6 a. Reattach LED tray and lens back to the fixture. b. Secure lens to housing with lens latches. c. Turn on circuit breaker and test light. 8 Product Details Recommended Dimmers Brand LEVITON LUTRON LUTRON LUTRON PHILIPS Sccaonmfpoarttihbelefudillmmer list! Model ILLUMATECH IP710-LFZ DIVADVSTV Maestro MS-Z101 Nova T NTSTV Sunrise SR1200ZTUNV VT_DU-WH-3550K Specifications Voltage Wattage Power Factor Beam Angle Efficacy Housing Material Dimmable 120V-277V 38W/46W/54W >0.9 110° 130 lm/w PC+Steel 0-10V Average Lifetime Lumens Moisture Rating CRI Usage Amps Warranty 50,000 hrs 5000/6000/7000lm Wet 80 Indoor 0.45A 7 Years 9 Product Details VT2_25SW-GR-3550K Specifications Voltage Wattage Power Factor Beam Angle Efficacy Housing Material Dimmable 120V-277V 15W/20W/25W >0.9 110° 130 lm/w PC+Steel 0-10V Average Lifetime Lumens Moisture Rating CRI Usage Amps Warranty 50,000 hrs 1950/2600/3250lm Wet 80 Indoor 0.21A 7 Years VT8_90SW-GR-3550K Specifications Voltage Wattage Power Factor Beam Angle Efficacy Housing Material Dimmable 120V-277V 16W/75W/90W >0.9 110° 130 lm/w Polycarbonate 0-10V Average Lifetime Lumens Moisture Rating CRI Usage Amps Warranty 50,000 hrs 8450/9750/11700lm Wet 80 Indoor 0.19-0.75A 7 Years 10 Common Troubleshooting We've got you covered! Our troubleshooting section is here to shed some light and provide you with easy-to-follow solutions for any problem. If you still need some assistance, feel free to contact us. Our team of lighting experts are happy to help brighten your day. Installation Light isn't turning on. Double check if fixture is properly connected and circuit breaker hasn't been tripped. Light isn't bright enough. Dimming Light not dimming to lowest setting. Light not dimming smoothly. Light not compatible with dimmer switch. Flickering Light is flickering when turning on. Light flickering with lights on the same circuit. Light flickering when turned on. Light flickering when dimmed. Buzzing Fixture buzzing with power outages. Fixture buzzing with appliances. Fixture buzzing when dimmed. Check proper wattage & for unobstructed fixture. Ensure minimum dimmer load requirement is met. Verify dimmer compatibility with fixture. Check light-dimmer compatibility. Consider purchasing compatible switch if necessary. Check that fixture wiring connections are secure. Prevent circuit overload from lights. Verify fixture compatibility and that it is grounded. Verify dimmer switch compatibility. Confirm secure surge protector link for light. Look for nearby interferences that can cause buzzing. Such as televisions, radios, etc. Verify dimmer switch compatibility. 11 Light Distribution Angle VT_DU-WH-3550K&VT8_90SW-GR-3550K Not No awloirgrhietisn, ygonuercda?n skip this page VT2_25SW-GR-3550K AVERAGE BEAM ANGLE (50%): 110.8 DEG C0/180 120.0° C90/270 101.6° UNIT:cd Luminous Intensity Distribution 1 Not No awloirgrhietisn, ygonuercda?n skip this page AVERAGE BEAM ANGLE (50%): 107.3 DEG C0/180 115.8° C90/270 98.9° UNIT:cd Luminous Intensity Distribution 1 The lighting distribution angle determines how light spreads from a source and impacts its illumination. Two main types exist: symmetric and asymmetric. Symmetric Lighting: This emits light evenly in all directions, forming a cone-shaped pattern. Great for general lighting in large areas, it's used for tasks like area illumination, security, and perimeter lighting. Also applied in up-lighting. Asymmetric Lighting (Beam Angle): This directs light in a specific direction, reducin glare and spill. Ideal for task lighting, it's common in settings like landscapes, retail stores, and museums. Note: Reflectors, lenses, and source to surface distance can affect the lighting distribution angle. 12 Lighting made better. support@sunco.com (844) 334-9938 REV1.0Adobe PDF Library 17.0 Adobe InDesign 19.0 (Windows)