Instruction Manual for solaredge models including: SE3000H Single Phase Energy Hub Inverter, SE3000H, Single Phase Energy Hub Inverter, Phase Energy Hub Inverter, Energy Hub Inverter, Hub Inverter, Inverter

nullHOME BACKUPsolaredge.comOptimised battery storage with HD-Wave technologySingle string design for inverters up to 5kW AC Advanced safety features including SafeDC™, rapid shutdown, and integrated arc fault protectionBuilt-in panel-level monitoring Rapid inverter commissioning via smartphone using SetAppIP65-rated, for indoor and outdoor installationsSmall, lightweight, and easy to installRecord-breaking 99% weighted efficiency with 200% DC oversizing, for higher energy yieldModular design, future ready

Advertisement, Poster, Text

Adobe InDesign 16.1 (Macintosh)

SE3000H-SE10000H Single Phase Energy Hub Inverter with Prism Technology

SolarEdge 5.0kW Inverter 1Phase With Prism Technology

Single Phase Energy Hub Inverter with Prism Technology - Herholdt's

Author: Adobe InDesign 16.1 \(Macintosh\) Subject: nullHOME BACKUPsolaredge.comOptimised battery storage with HD-Wave technologySingle string design for inverters up to 5kW AC A\൤vanced safety features including SafeDC™, rapid shutdown, and integrated arc fault protectionBuilt-in panel-level monitoring Ra對pid inverter commissioning via


File Info : application/pdf, 3 Pages, 542.68KB

PDF preview unavailable. Download the PDF instead.

103652 - SE3000H-SE10000H Single Phase Energy Hub Inverter with Prism Technology
HOME BACKUP

Single Phase Energy Hub Inverter with Prism Technology
For Australia and New Zealand
SE3000H-XXX / SE4000H-XXX / SE5000H-XXX / SE6000H-XXX /SE8250H-XXX / SE10000H-XXX
12-25
YEAR WARRANTY

Optimised battery storage with HD-Wave technology

Single string design for inverters up to 5kW AC
Record-breaking 99% weighted efficiency with 200% DC oversizing, for higher energy yield
Modular design, future ready with optional upgrades enabling:
Full home backup power High efficiency DC-coupled storage Backup generator connection EV charging, with SolarEdge Smart EV Charger
Built-in consumption monitoring
Multi-inverter, scalable storage solution
solaredge.com

Advanced safety features including SafeDCTM, rapid shutdown, and integrated arc fault protection Built-in panel-level monitoring
Rapid inverter commissioning via smartphone using SetApp
Small, lightweight, and easy to install
IP65-rated, for indoor and outdoor installations

Single Phase Energy Hub Inverter with Prism Technology
For Australia and New Zealand
SE3000H-XXX / SE4000H-XXX / SE5000H-XXX / SE6000H-XXX / SE8250H-XXX / SE10000H-XXX(1)

SE3000H-XXX SE4000H-XXX SE5000H-XXX SE6000H-XXX SE8250H-XXX SE10000H-XXX UNITS

OUTPUT - AC ON GRID

Rated AC Power Maximum AC Power Output AC Output Voltage (Nominal) AC Output Voltage Range AC Frequency Range (nominal) Maximum Continuous Output Current Total Harmonic Distortion (THD) Power Factor Utility Monitoring, Islanding Protection, Country Configurable Thresholds Charge Battery from AC (if allowed) Typical Nighttime Power Consumption
OUTPUT - AC BACKUP(2)
Rated AC Power in Backup Operation(3) AC Output Voltage (Nominal) AC Output Voltage Range AC Frequency Maximum Continuous Output Current in Backup Operation(4)
INPUT - DC (PV AND BATTERY)

3000 3000
14
3000 14

4000 4000
18.5
4000 18.5

5000

6000

5000

6000

220 / 230

184 - 264.5

50/60 ± 5

23

27.5

<3

1, adjustable -0.8 to 0.8

Yes

Yes <2.5

5000

6000

220 / 230

184-264.5

50/60 ± 5

23

27.5

8250 8250
37.5

10000

VA

10000

VA

Vac

Vac

Hz

45.5

A

%

7400 34

W

9000

W

Vac

Vac

Hz

41.5

A

Transformer-less, Ungrounded Max Input Voltage Nom DC Input Voltage Reverse-Polarity Protection Ground-Fault Isolation Detection Maximum DC PV Power Maximum Input Current(5) Maximum Inverter Efficiency European Weighted Efficiency 2-pole Disconnection

Yes

480

Vdc

380

400

Vdc

Yes

600k Sensitivity

6000

8000

10000

12000

16500

20000

W

8.5

11

14

16.5

22.5

25.5

Adc

99.2

%

98.8

99

%

Yes

BATTERY STORAGE

Supported Battery Types Number of Batteries per Inverter Continuous Power
SMART ENERGY CAPABILITIES
Consumption Metering Battery Storage EV Charging

SolarEdge Energy Bank Battery, LG RESU10H Prime, LG RESU16H Prime Up to 3 SolarEdge Energy Bank Batteries or up to 2 LG Prime batteries(6)
Up to inverter rated power
Built-in(7) In backup: Up to 3 inverters, 88.2kWh with SolarEdge Energy Bank Battery
Smart EV ready - separate EV charger and cabling required

(1) These specifications apply to inverters with part numbers SExxxxH-AUS3xxxxx and connection unit model number DCD-1PH-AU-PxH-F-x (2) Not designed for standalone applications and requires AC for commissioning (3) Rated AC power in Backup Operation are valid for installations with multiple inverters. For a single backup inverter operation, rated AC power in backup is 90% of the stated value (4) Rated current in backup operation are valid for installations with multiple inverters. For a single backup inverter operation, rated current in backup is 90% of the stated value (5) A higher current source may be used; the inverter will limit its input current to the values stated (6) Support for 2 LG Prime batteries with compatible inverter firmware (7) For consumption metering current transformers should be ordered separately: SE-CTML-0350-070 or SE-ACT-0750-100 or SE-ACT-0750-250

Single Phase Energy Hub Inverter with Prism Technology
For Australia and New Zealand
SE3000H-XXX / SE4000H-XXX / SE5000H-XXX / SE6000H-XXX / SE8250H-XXX / SE10000H-XXX(1)

SE3000H-XXX SE4000H-XXX SE5000H-XXX SE6000H-XXX SE8250H-XXX SE10000H-XXX UNITS

ADDITIONAL FEATURES

Supported Communication Interfaces

RS485 - Modbus devices, RS485 - SE protocol, Ethernet, Wi-Fi, EnergyNet

Integrated AC, DC and Communication Connection Unit

Yes

Inverter Commissioning

With the SetApp mobile application using built-in Wi-Fi Access Point for local connection

STANDARD COMPLIANCE

Safety

IEC-62103 (EN50178), IEC-62109, AS/NZS3100

Grid Connection Standards

AS/NSZ 4777.2:2020, EN 50549-1

Emissions

Photovoltaic Inverter Battery Inverter

Listing

Photovoltaic and Battery Inverter Multiple Mode Inverter (Battery only) Multiple Mode Inverter

INSTALLATION SPECIFICATIONS

IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12 SExxxxxH SExxxxxK-B
SExxxxxK-BPV SExxxxxK-MMB SExxxxxK-MM

AC Output and DC Input Conduit Size / Wire Cross Section

32 mm Maximum / 1-10 mm2

Dimensions with Connection Unit (H x W x D)

450 x 370 x 174

540 x 370 x 185

Weight with Connection Unit

<15

<20

Communication Glands

2

kg

Noise

<25

<50

dBA

Cooling

Natural convection

Operating Temperature Range

-40 to +60(8)

°C

Protection Rating

IP65 - Outdoor and Indoor

Manufacturing Countries

China / Vietnam / Hungary

(8) Full power up to at least 50°C; for power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note.pdf

Connecting CTs to the Revenue Grade and Consumption Meter

Main electrical cabinet

Single Phase Energy Hub Inverter with Prism Technology and built-in smart energy metering

CT extension cable metering* (shielded twisted pair). Recommended sheath rating: 600V (300V min)

AC cable conduit
* One CT for import/export or consumption metering
© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 10/2021 DS-000118-1.0-AUS-NZ. Subject to change without notice.



References