Instruction Manual for solaredge models including: SE3000H Single Phase Energy Hub Inverter, SE3000H, Single Phase Energy Hub Inverter, Phase Energy Hub Inverter, Energy Hub Inverter, Hub Inverter, Inverter
SolarEdge 5.0kW Inverter 1Phase With Prism Technology
Author: Adobe InDesign 16.1 \(Macintosh\) Subject: nullHOME BACKUPsolaredge.comOptimised battery storage with HD-Wave technologySingle string design for inverters up to 5kW AC A\vanced safety features including SafeDC™, rapid shutdown, and integrated arc fault protectionBuilt-in panel-level monitoring Ra對pid inverter commissioning via
File Info : application/pdf, 3 Pages, 542.68KB
DocumentDocumentHOME BACKUP Single Phase Energy Hub Inverter with Prism Technology For Australia and New Zealand SE3000H-XXX / SE4000H-XXX / SE5000H-XXX / SE6000H-XXX /SE8250H-XXX / SE10000H-XXX 12-25 YEAR WARRANTY Optimised battery storage with HD-Wave technology Single string design for inverters up to 5kW AC Record-breaking 99% weighted efficiency with 200% DC oversizing, for higher energy yield Modular design, future ready with optional upgrades enabling: Full home backup power High efficiency DC-coupled storage Backup generator connection EV charging, with SolarEdge Smart EV Charger Built-in consumption monitoring Multi-inverter, scalable storage solution solaredge.com Advanced safety features including SafeDCTM, rapid shutdown, and integrated arc fault protection Built-in panel-level monitoring Rapid inverter commissioning via smartphone using SetApp Small, lightweight, and easy to install IP65-rated, for indoor and outdoor installations Single Phase Energy Hub Inverter with Prism Technology For Australia and New Zealand SE3000H-XXX / SE4000H-XXX / SE5000H-XXX / SE6000H-XXX / SE8250H-XXX / SE10000H-XXX(1) SE3000H-XXX SE4000H-XXX SE5000H-XXX SE6000H-XXX SE8250H-XXX SE10000H-XXX UNITS OUTPUT - AC ON GRID Rated AC Power Maximum AC Power Output AC Output Voltage (Nominal) AC Output Voltage Range AC Frequency Range (nominal) Maximum Continuous Output Current Total Harmonic Distortion (THD) Power Factor Utility Monitoring, Islanding Protection, Country Configurable Thresholds Charge Battery from AC (if allowed) Typical Nighttime Power Consumption OUTPUT - AC BACKUP(2) Rated AC Power in Backup Operation(3) AC Output Voltage (Nominal) AC Output Voltage Range AC Frequency Maximum Continuous Output Current in Backup Operation(4) INPUT - DC (PV AND BATTERY) 3000 3000 14 3000 14 4000 4000 18.5 4000 18.5 5000 6000 5000 6000 220 / 230 184 - 264.5 50/60 ± 5 23 27.5 <3 1, adjustable -0.8 to 0.8 Yes Yes <2.5 5000 6000 220 / 230 184-264.5 50/60 ± 5 23 27.5 8250 8250 37.5 10000 VA 10000 VA Vac Vac Hz 45.5 A % 7400 34 W 9000 W Vac Vac Hz 41.5 A Transformer-less, Ungrounded Max Input Voltage Nom DC Input Voltage Reverse-Polarity Protection Ground-Fault Isolation Detection Maximum DC PV Power Maximum Input Current(5) Maximum Inverter Efficiency European Weighted Efficiency 2-pole Disconnection Yes 480 Vdc 380 400 Vdc Yes 600k Sensitivity 6000 8000 10000 12000 16500 20000 W 8.5 11 14 16.5 22.5 25.5 Adc 99.2 % 98.8 99 % Yes BATTERY STORAGE Supported Battery Types Number of Batteries per Inverter Continuous Power SMART ENERGY CAPABILITIES Consumption Metering Battery Storage EV Charging SolarEdge Energy Bank Battery, LG RESU10H Prime, LG RESU16H Prime Up to 3 SolarEdge Energy Bank Batteries or up to 2 LG Prime batteries(6) Up to inverter rated power Built-in(7) In backup: Up to 3 inverters, 88.2kWh with SolarEdge Energy Bank Battery Smart EV ready - separate EV charger and cabling required (1) These specifications apply to inverters with part numbers SExxxxH-AUS3xxxxx and connection unit model number DCD-1PH-AU-PxH-F-x (2) Not designed for standalone applications and requires AC for commissioning (3) Rated AC power in Backup Operation are valid for installations with multiple inverters. For a single backup inverter operation, rated AC power in backup is 90% of the stated value (4) Rated current in backup operation are valid for installations with multiple inverters. For a single backup inverter operation, rated current in backup is 90% of the stated value (5) A higher current source may be used; the inverter will limit its input current to the values stated (6) Support for 2 LG Prime batteries with compatible inverter firmware (7) For consumption metering current transformers should be ordered separately: SE-CTML-0350-070 or SE-ACT-0750-100 or SE-ACT-0750-250 Single Phase Energy Hub Inverter with Prism Technology For Australia and New Zealand SE3000H-XXX / SE4000H-XXX / SE5000H-XXX / SE6000H-XXX / SE8250H-XXX / SE10000H-XXX(1) SE3000H-XXX SE4000H-XXX SE5000H-XXX SE6000H-XXX SE8250H-XXX SE10000H-XXX UNITS ADDITIONAL FEATURES Supported Communication Interfaces RS485 - Modbus devices, RS485 - SE protocol, Ethernet, Wi-Fi, EnergyNet Integrated AC, DC and Communication Connection Unit Yes Inverter Commissioning With the SetApp mobile application using built-in Wi-Fi Access Point for local connection STANDARD COMPLIANCE Safety IEC-62103 (EN50178), IEC-62109, AS/NZS3100 Grid Connection Standards AS/NSZ 4777.2:2020, EN 50549-1 Emissions Photovoltaic Inverter Battery Inverter Listing Photovoltaic and Battery Inverter Multiple Mode Inverter (Battery only) Multiple Mode Inverter INSTALLATION SPECIFICATIONS IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12 SExxxxxH SExxxxxK-B SExxxxxK-BPV SExxxxxK-MMB SExxxxxK-MM AC Output and DC Input Conduit Size / Wire Cross Section 32 mm Maximum / 1-10 mm2 Dimensions with Connection Unit (H x W x D) 450 x 370 x 174 540 x 370 x 185 Weight with Connection Unit <15 <20 Communication Glands 2 kg Noise <25 <50 dBA Cooling Natural convection Operating Temperature Range -40 to +60(8) °C Protection Rating IP65 - Outdoor and Indoor Manufacturing Countries China / Vietnam / Hungary (8) Full power up to at least 50°C; for power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note.pdf Connecting CTs to the Revenue Grade and Consumption Meter Main electrical cabinet Single Phase Energy Hub Inverter with Prism Technology and built-in smart energy metering CT extension cable metering* (shielded twisted pair). Recommended sheath rating: 600V (300V min) AC cable conduit * One CT for import/export or consumption metering © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 10/2021 DS-000118-1.0-AUS-NZ. Subject to change without notice.