Instruction Manual for ELKAY models including: LZS8WSLP Enhanced Smart Connected Ready Retrofit Kit, LZS8WSLP, Enhanced Smart Connected Ready Retrofit Kit, Connected Ready Retrofit Kit, Ready Retrofit Kit, Retrofit Kit
1100000020 | Elkay
To insure you install this Kit easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHE
File Info : application/pdf, 7 Pages, 5.08MB
DocumentDocument1100000020 INSTALLATION MANUAL ENHANCED SMART CONNECTED-READY RETROFIT KIT THIS ACCESSORY IS AUTHORIZED FOR MODELS LZS8WSLP, LZS8WSSP, LZSTL8WSLP, AND LZSTL8WSSP WITH SERIAL NUMBERS BEGINNING WITH 1905 OR HIGHER. IMPORTANT THIS IS AN INDOOR APPLICATION ONLY. ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON. TOOLS REQUIRED BUT NOT PROVIDED: GLOVES SAFETY GLASSES 5/16 NUT DRIVER (HIGHLY RECOMMENDED) FLAT HEAD SCREWDRIVER T-10 TORX SCREWDRIVER 5/32 ALLEN WRENCH 1/4" NUT DRIVER IMPORTANT! INSTALLER PLEASE NOTE. INSTALLER To insure you install this Kit easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES. Patent zurn-elkay.com/patents WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov ADVERTENCIA: Cáncer y daño reproductivo - www.P65Warnings.ca.gov AVERTISSEMENT: Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov Page 1 2000001094 (Rev. B - 12/06) Kit Includes 1100000020 2 1 5 4 3 7 6 Item No. 1 2 3 4 5 6 7 PARTS LIST Description PCBA, ENDPOINT BOARD (CONNECTED READY) BRACKET, ENDPOINT BOARD MOUNTING ENDPOINT WIRING HARNESS PCBA, MAIN CONTROL BOARD (CONNECTED READY) SCREW-#8 X .50 HI-LOW 6 LOBE PAN HEAD (4 QTY) LABEL, FCCID plumbSMART REGISTRATION ID LABEL 2000001094 (Rev. B - 12/06) Page 2 Installation Procedure 1100000020 1. Disconnect electrical power to the unit. 5. Disconnect connection J1, J8 & J9 shown below. 2. Turn off water supply. 3. Remove two (2) mounting screws with 5/32" Allen wrench and pull bottle filler off the wall mounting plate. Note: Do not discard mounting screws, they will be needed to reinstall. J8 J9 Screws J1 6. Remove (4) T-10 Torx screws to remove control board. Note: Do not discard mounting screws, they will be needed to reinstall. Screws CAUTION Make sure power is disconnected prior to retrofitting. 4. Remove (2) screws to remove Main control board cover using 1/4" nut driver. Note: Do not discard mounting screws, they will be needed to reinstall. 7. Replace new connected-ready control board and refasten using (4) T-10 Torx screws. Screws Screws 8. Reconnect cable connections J1, J8 and J9. 9. Snap on Endpoint board to plastic bracket and attach harness as shown below. Page 3 2000001094 (Rev. B - 12/06) 1100000020 10. If top cap stiffener piece is installed, remove by simply pulling out. Install endpoint board assembly by sliding inside using rail feature shown below. Ensure it is secured properly. Endpoint Board Assembly 13. Apply plumbSMART registration ID label at desired location. Recommended on cover (shown below) or next to the product label underneath of basin (at step 15). Avoid any location that has the potential for vandalism / damage to registration ID information. Rail feature 11. Connect endpoint board cable to J7 connector on the main board, as shown below. 14. Install back bottle filler to the wall mounting plate and refasten using (2) screws making sure gasket is properly placed beneath the bottle filler. Screws Endpoint Board J7 cable 12. Replace the main control board cover. Ensure all the cable are organized to exit from the cable opening as shown and refasten the cover using (2) screws. 15. Apply FCC ID lable received in the kit and paste it on the product data label to overwrite existing FCC information, as shown below. 2000001094 (Rev. B - 12/06) Page 4 1100000020 16. Turn ON water supply and electrical power to the unit. Visually check for any leaks. Once power is applied to the bottle filler, the GREEN LED light should illuminate showing good filter status (if equipped with filter) along with the LCD Bottle Counter. 17. Verify proper dispensing by placing cup or any opaque object in front of sensor area and verify water dispenses and bottle count advances. If air in system causes the stream to be opaque, run until stream is clear. Page 5 2000001094 (Rev. B - 12/06) Wiring Diagram 1100000020 End-point board Solenoid Valve Earthing Wire harness 7-pin 8-pin 6-pin Control Board 6-pin 2-wire, L,N AC A pair of 24-pin connectors mated 3-wire Alcove LED 4-wire 4-pin 8-wire IR board NFC board 4-pin 4-wire Earthing L, AC pow er N, AC power Reset switch Energy save relay Register in plumbSMART 1. Install Zurn Gateway (required and sold separately) per the gateway instructions manual, if an existing gateway is not within communication range. 2. If you have not already set up an enterprise account and your administrator access, Zurn creates your Enterprise Account for you! (You will be required to identify your building location, number of floors, and number of rooms.) and request plumbSMART administrator account at 844-987-6737 3. Log into plumbsmart.zurn.com 4. Register each Connected product in plumbSMART (Watch How-To videos to get started. Located in the support section inside the portal.) Note: Refer to the plumbSMART Registration ID label provided with Retrofit Kit product. 2000001094 (Rev. B - 12/06) Page 6 1100000020 FCC COMPLIANCE STATEMENT CAUTION: Changes or modifications not expressly approved could void your authority to use this equipment This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: --Reorient or relocate the receiving antenna. --Increase the separation between the equipment and receiver. --Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --Consult the dealer or an experienced radio/TV technician for help. The device shall be used in such a manner that the potential for human contact normal operation is minimized. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. INDUSTRY CANADA STATEMENT This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de license. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. The device shall be used in such a manner that the potential for human contact normal operation is minimized. This equipment complies with RSS-102 radiation exposure limits. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. Le dispositif doit être utilisé de manière à minimiser le potentiel de fonctionnement normal par contact humain. Cet équipement est conforme aux limites d'exposition au rayonnement RSS-102. Cet équipement doit être installé et utilisé avec une distance minimale de 20 cm entre le radiateur et votre corps. Cet appareil et son (ses) antenne (s) ne doivent pas être co-localisés ou utilisés conjointement avec une autre antenne ou un autre émetteur. FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816 PARA PIEZAS, CONTACTE A SU DISTRIBUIDOR LOCAL O LLAME AL 1.800.834.4816 POUR OBTENIR DES PIÈCES, CONTACTEZ VOTRE DISTRIBUTEUR LOCAL OU COMPOSEZ LE 1.800.834.4816 PRINTED IN U.S.A. IMPRESO EN LOS E.E.U.U. IMPRIMÉ AUX É.-U. REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640 NÚMERO GRATIS DE SERVICIO 1.800.260.6640 INFORMATIONS POUR LE SERVICE PAR NUMERO SANS FRAIS 1.800.260.6640 ELKAY MANUFACTURING COMPANY · 1333 BUTTERFIELD ROAD SUITE 200 DOWNERS GROVE, IL 60515 USA · 630.574.8484 · www.elkay.com Page 7 2000001094 (Rev. B - 12/06)