Owner's Manual for esse-ti models including: LifTrack Monitoring System, Monitoring System, System
LifTrack - Esse-ti
File Info : application/pdf, 14 Pages, 1,013.47KB
DocumentDocumentTable of contents General description 3 Hardware description 4 Installation 5 Configuration 7 Self-learning procedure 13 Note 13 2 General description LifTrack is a real-time monitoring system for lift systems Equipped with predictive analysis functions, it provides the information needed for routine and preventive maintenance, regardless of the brand of lift LifTrack has: - 2 sensors (accelerometer and barometer) - 4 digital inputs - 1 analogue input - 1 relay output (NO/NC, bistable) LifTrack (installed integral with the car) processes the data collected from the sensors and inputs and forwards it, via CAN-bus connection, to the alarm system or to the Esse-ti gateway already present on the installation. Via data connection, the information is then sent to an Esse-ti server and is made available in the e-stant web application Main information provided by the sensors: - car position at floor - journeys made - number of stops on each floor - number of reversals - average and instantaneous speed - average and instantaneous acceleration - distance covered - time of journey - temperature - pressure Examples of information that can be detected by connecting the inputs to the control panel or external sensor: - door status - lighting efficiency (by means of light sensors) - presence of people inside the car (by means of movement sensors) - presence of water in the pit (by means of flood sensors) - presence of smoke (by means of smoke detectors) - overloading (by means of weight sensors on the car floor) The integrated relay and the relays of the Esse-ti alarm system or gateway allow active maintenance to be carried out remotely or locally (according to pre-programmed logic) 3 Hardware description A Micro USB AB port for PC connection B Not used C CAN-bus termination dip switch* D Analog input trimmer E Terminal blocks Terminal blocks +5 + IN1 IN1 IN2 IN2 IN3 IN3 IN4 IN4 IN5 + IN5 RL NO RL C RL NC CAN H CAN L 5 Vdc ouput 11-40 Vdc power supply input Negative pole Digital input IN1 Digital input IN1 Digital input IN2 Digital input IN2 Digital input IN3 Digital input IN3 Digital input IN4 Digital input IN4 Analog input IN5 (positive pole) Analog input IN5 (negative pole) Relay (normally open contact) Relay (common contact) Relay (normally closed contact) CAN-bus H CAN-bus L *set the switch n° 1 to ON if Liftrack is the last device on the bus (after the move, the alarm system or gateway connected to LifTrack must be restarted) 4 Installation 1. Fix LifTrack to the car top 2. Connect LifTrack to the Esse-ti alarm system or gateway already present on the installation via CAN-bus Example of connection to Helpy 2W-4G.VoLTE or to 4G.VoLTE 5 Example of connection to 4G.evox 3. Move the car to the lowest floor and place the Reed sensor on the roof; fix the metal plate to the wall and centre the magnetic disk, as shown in the picture 4. Connect the Reed sensor to one of LifTrack's inputs (e.g. IN1) 5. For the initial self-learning procedure only, connect a lift motion signal to LifTrack (e.g. to input IN2) NOTE: in the absence of a lift motion signal, it is possible to connect a button to be held down while the lift is in movement 6. Power on LifTrack 6 Configuration LifTrack can be configured: - remotely via e-stant web application (data connection provided by the Esse-ti alarm system or gateway present on the installation) - locally via micro USB port and e-stant software Configuration via e-stant web NOTE: please refer to the e-stant web guide for registering to the service and for entering, registering and programming the devices 1. Access e-stant web 2. Enter a new lift or select an existing lift in the lifts list 3. Click on the device button and check that LifTrack is selected in the field Main data connection mode 4. Fill in the fields Number of floors and Lower floor 5. Click on Save button 6. Click on button to remotely configure the device 7. Click on OK to start remote connection with device 8. Wait for connection confirmation NOTE: please follow steps from 9 to 18 only when connecting to Helpy 2W-4G.VoLTE; go to step 19 when connecting to 4G.VoLTE or to 4G.evox 7 9. Click on Data connection -> DB-9 connection 10. Select Port type (button will turn blue) 11. From Mode menu select CAN-bus 12. Select Port settings (button will turn blue) 13. From Speed menu select 125 kbps 14. Click on Send selected parameters (buttons will turn green) 15. Click on Data connection -> CAN-bus 16. Select (50065) Device ID (button will turn blue) 17. Enter the value 000 in all fields ID1I...ID8 18. Click on Send selected parameters (buttons will turn green) 8 19. Click on LifTrack (NOTE: in the case of the first CAN-bus configuration, the Liftrack item may be displayed approximately 1 minute after step 18) 20.Click on Settings 21. Select the Config buttons for inputs 1 and 2 (buttons will turn blue) 22. In the Function menu of input 1, select Floor zero 23. In the Type menu of input 1, select Normally open 24. In the Function menu of input 2, select Motion 25. In the Type menu of input 2, select Normally open or Normally closed according to the type of lift motion signal used 26. Click on Send selected parameters (buttons will turn green) 9 NOTE: if the connection and configuration of the Reed sensor are correct, the dashboard will light up Input 1 when the lift is at the lowest floor NOTE: if the connection and configuration of the lift motion signal (or pushbutton) are correct, the dashboard will light up Input 2 when the lift is moving (or the pushbutton is pressed) 27. Click on Management 28. Click on the Calibration button to start the Liftrack calibration procedure 10 29. Click on Yes to confirm At the end of the calibration procedure, the dashboard displays "Done". 30. Click on the Learning button to start the Liftrack self-learning procedure 11 WARNING: before clicking on Yes, make sure that the car is at the lowest floor 31.Click on Yes to confirm 32. Within 15 minutes, run the self-learning procedure described in the next paragraph At the end of the procedure, the dashboard displays "Done". 12 Self-learning procedure LifTrack requires the self-learning procedure to acquire information on the number and position of floors Procedure: - move the car from the lowest to the highest floor, stopping at each floor for the time required by the opening and closing of the doors (if a pushbutton is connected to input 2, press it every time the car moves from one floor to another and release it when the car stops at the floor) - once you have reached the highest floor, you shall move the car directly to the lowest floor without intermediate stops Note If a pushbutton has been used in the absence of a lift motion signal, the pushbutton must be disconnected at the end of the self-learning procedure and the input programming must be cleared: 13 Esse-ti S.r.l. Via G. Capodaglio, 9 62019 Recanati (MC) ITALY Tel. +39 071 7506066 www.esse-ti.it support@esse-ti.it